压缩机技术指南手册(B型)

合集下载

HIBLOW系列压缩机操作与维护技术手册说明书

HIBLOW系列压缩机操作与维护技术手册说明书
DANGER: Improper installation of the grounding plug can result in a risk of electric shock. If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either flat blade terminal. The wire with insulation having an outer surface that is green, with or without yellow stripes, is the grounding wire.
The following is an explanation of the three different types of hazards: DANGER: Severe personal injury or death will occur if hazard is ignored. WARNING: Severe personal injury or death can occur if hazard is ignored. CAUTION: Minor injury or property damage can occur if hazard is ignored.
FOR PERMANENTLY CONNECTED PRODUCT
This product should be connected to a grounded, metallic, permanent wiring system, or an equipment-grounding terminal or lead on the product(refer to wiring diagram).

压缩机手册

压缩机手册

BE705N撬装式压缩机组使用维护技术手册北京伯肯新能源设备有限公司二○○九年十二月目 录前言安全事项0.1 综合安全事项0.2 操作安全事项0.3 维护安全事项第一章 CNG基础知识1.1 综述1.2 天然气汽车(NGV)基础知识1.3 加气站基础知识1.4 通用定义第二章设备简介与操作2.1 加气站综述2.2 零能安全状态2.3 压缩机组2.4 气路系统2.5 控制系统工作模式2.6 设备安装2.7 设备操作第三章 技术规格3.1 压缩机撬体技术参数3.2 主要部件元件参数第四章 设备维护保养4.1 概述4.2 电源的切断4.3 推荐维护程序4.4 各分系统维护要求4.5 故障处理4.6 维护记录第五章 附图5.1 系统原理图5.2 电气原理图5.3 各种(燃)气流组分的气缸/密封(填密件)润滑油建议安全事项0.1 综合安全事项如果操作不当,压缩气体将可能十分危险。

在进行加气站操作之前,请认真阅读并理解本章内容。

为避免故障的发生,必须遵守本手册所有的规定。

● 在距离任何气体装置10米的范围内不允许吸烟、有明火和无遮盖的灯光。

● 不要调整、拆除、设旁路通过任何安全保护装置。

● 操作、维护和修理操作只能由被授权的技术人员按照相应的操作和安全规程进行。

● 电气接线必须符合国家电气条例规范及有关地方法规之要求。

● 由用户提供的管件和其它部件必须适用于其对应的工作压力。

如果有必要,必须经过试验并安装卸压装置。

● 在进行修理和维护之前,系统必须完全排空天然气。

● 旋转的机械部件很危险,如果外壳和防护设施被拆卸,不要运转机器。

● 压缩机的操作人员应采用听力保护措施。

● 不要在压缩机设备附近储存可燃材料。

0.2 操作安全事项在操作CNG加气站之前必须阅读并理解以下内容:● 必须对压缩机进行维护、保养,以使其处于安全运行状态,应按照要求对压缩机进行定期检测。

● 压缩机设备只能按本手册给出的技术规范操作。

● 维护日志单和维护记录必须按设备供应商的要求填写并保存。

压缩机说明书

压缩机说明书

Z-0.28/(20-76)-250型天然气压缩机使用说明书ZNG20(II)·SM目录一、用途和适用范围二、主要规格及技术参数三、压缩机的主要结构及工作原理四、压缩机的安装五、压缩机的装配及拆卸注意事项六、压缩机的操作与使用七、压缩机的油封和保管八、运行故障与排除方法九、主要配合件装配间隙十、保证十一、产品成套设备、随机工具、备品备件、文件清单十二、随机安装图样一、用途和适用范围Z-0.28/(20-76)-250型天然气压缩机(以下简称压缩机),是将气体压力为2-20MPa 的净化天然气(经母站压缩机压缩,净化的天然气)压缩到25MPa,供气量为300-1350Nm3/h(吸气压力为2.0~7.6MPa时),输入车载气瓶内作为燃料代替汽油使用的主要设备。

该压缩机对天然气气质的要求:不含游离水,硫化氢(HS)含量<15mg/Nm3,低热2值≥31.4Mj/N m3,含尘量≤5mg/N m3,总硫含量(以硫计)≤100mg/N m3。

二、主要规格及技术参数(一)、压缩机1、型号:Z-0.28/(20-76)-2502、型式:Z型两级混冷活塞式3、压缩介质:净化天然气4、进气压力:2.0~20MPa5、压缩机启动压力:2.0~17MPa6、进气温度:≤30℃7、排气压力:25MPa8、排气温度:≤160℃(冷却前);≤环境温差+15℃(冷却后)9、排气量:0.28M3/min10、供气量:300~1350Nm3/h11、含油量:≤5ppm12、噪声:≤75dB(A)(箱体外1m处)13、传动方式:直联14、轴功率:≤72KW15、电机功率:75KW,防爆等级:dIIBT416、配电规格:50HZ,380V17、启动与控制(PLC)该机为全自动,即自动启停,自动排污。

主机软启动注油器启动后,主机延时启动。

(二)、主电动机:1、型号:YB315M-82、额定功率:75KW3、转速:740r/min4、电压:380V5、防爆等级:dIIBT4(三)、注油器电机:1、额定功率:0.55KW2、电压:380V3、防爆等级:dIIBT4(四)、控制柜:Z-0.28/(20-76)-250单机PLC控制柜(五)、风机电机(两台)1、额定功率:2×2KW2、电压:380V3、防爆等级:dIIBT4(六)、水泵电机1、额定功率:0.75KW2、电压:380V3、防爆等级:dIIBT4(七)、加热器功率约4×1.5KW三、压缩机的主要结构及工作原理:(一)、压缩机的主要结构压缩机为Z型,两级压缩,气体风冷、气缸内循环水冷活塞式,气缸中心线为竖直方向。

压缩机说明书

压缩机说明书

压缩机说明书压缩机说明书篇一:空气压缩机使用说明书空气压缩机使用说明书一、操作注意事项:1、压缩机必须定期检修,并保证在良好工作状态下工作。

2、在压缩机组运行前,必须注意不可有人在机器上进行检修工作。

3、压缩机应在技术规范规定的范围内运行。

4、不可以在可能吸入易燃、有毒或腐蚀性蒸汽或气体的环境中运行压缩机。

5、注意人不可以接触管路系统,尤其是排气管或是在运行中的高温部件。

6、压缩机组运行时,操作人员不可做其他别的工作,以适时监控压缩机组的运行状态。

二、维修工作注意事项:1、维修工作只可在停机并完全放空的压缩机上运行。

若有必要,将压缩机系统内的高压气体放空。

首先应断开电源控制箱的总闸,为了防止误开机组,应将总闸锁上,或者贴一张相应的指示标签。

2、开始工作前,应全部打开凝液分离器上的手动排水阀,使得压缩机组完全放空,没有压力。

3、每次修理或改造安全设备时,如果要求有修改后检查合格证的,必须经有关监测主管部门重新验收认可。

4、在压缩机组上,只可用原装备件和推荐使用的零部件进行维修。

5、在维修时要严格保持清洁,拆下的零件应置于干净的地方,并对不同的零件采取用布、纸或胶布遮盖起来,以防尘污。

6、维修后,检查一下确定没有工具,零部件和抹布留在压缩机组上面或者里面。

7、压缩机组完全降温前,决不可用易燃溶剂清洗零部件。

零部件用溶剂清洗后,然后用压缩空气将零部件吹洗干净。

8、用压缩空气吹设备时,应十分小心,并戴护目镜。

三、压缩机的主要性能参数:a、公称容积流量: 3m3/minb、吸气压力: 0.1MPac、额定排气压力: 4.0MPad、吸气温度:≤45℃e、各级排气温度:<180℃f、输气温度:≤50℃g、压缩介质:空气h、冷却水耗量:≥3.5 m3/hi、润滑油温度:≤70℃j、气缸直径:一级φ285mm二级φ155mm三级φ75mmk、活塞行程: 95mml、转速:740r/minm、配备动力: Y280M-8,740r/min,450KW, AC380V/50Hz IP44 B3n、压缩机外形尺寸(长×宽×高):~2350×1900×1500(mm)o、全机重量:2500kgp、震动烈度:≤28.0q、各级排气压力:一级排气压力:0.27~0.37MPa二级排气压力:1.2~1.39MPa三级排气压力:4.0MPa四、气路系统:气路系统的作用,主要是将气体引向压缩机,经压缩机各级压缩之后,再引向使用场所,本机的主要气路流程示意如下:其中空气滤清器、一级气缸、一级冷却器、二级气缸、二级冷却器、二级油水分离器、三级气缸、三级冷却器、三级油水分离器和以上部件连接的管道组成压缩机的气路主管路,排除油、水用的排污管路以及连接压力表的管路和控制管路等组成压缩机气路的辅助管路;用户在使用该机前,必须增加后续管道和阀门分别与送气接头、排污接头相连接,以备把压缩空气送至使用场所和把油水引至合适的位置排放掉,本机的排污是自动排污,排放的时间间隔约为20~30min排放一次,排放时间约为10s,用户可根据当地的空气湿度进行适当的调整。

压缩机应用手册

压缩机应用手册

• • • •
6-启动继电器 检查启动继电器是否符合标准。 6.1 PTC继电器 用电阻表测量端子之间的电阻。在室温条件下,其 数值必须接近额定的数值: • 继电器-PTC电阻(Ω) • QP2-15 15+3-4 • JTX-520F 33±15%
• 7 - 启动电容器 • 7.1 启动电容器不合适 • 检查电容和电压值是否适合压缩机。如果电容值 不对,更换推荐的电容器。 • 7.2 启动电容器有故障 • 检查输出电压与电容器上标注的电压相同。 • 注意:不要触摸已充电的电容器端子,可能致人 死亡。 • 如果电容器泄漏或有裂逢,必须更换。
• 5-热保护器 • 5.1 过载保护器不合适 • 检查是否使用推荐的过载保护器。如果没有,更换规定的 启动继电器和保护装臵。如果有必要,向厂家咨询。 • 5.2 过载保护器有故障 • 3/4″圆盘热保护器 • 检查端子是否氧化,双金属热保护器圆盘是否变形。同时 检查端子之间是否有连续性。如果受到损坏或没有电流, 更换保护器。 • 热保护器 4TM • 检查端子是否氧化(插头和插座),它们之间是否有连续 性。如果受到损坏或没有电流,更换4TM保护器。
举例说明: 冰箱制冷过度(冰箱主要故障表中的编号1-第一部分)。 可能的原因: 连接盒中错误连接。 步骤: 第2.2条.在手册中找到该条目时,你会读到: 参照冰箱电路图,检查连接点。如果连接正确,再回到表 中,你会在第一栏中找到另一个1。这可能是该故障的另 一个原因: • 温控器不能关闭。你会在同一行中找到应采取的步骤(第 4.3条)。查找手册的该条目,就会看到应采取的步骤: 检查是否正确安装了温控器球管。把温控器的旋钮转到最 低点(最不冷),检查压缩机是否断开。如果故障还在, 就更换温控器。如果需要,你还会找到故障的其它原因, 每一种原因就会有相应的解决步骤。

压缩机使用说明书

压缩机使用说明书

压缩机使用说明书1.概述2.主要性能参数3.各系统说明4.主机主要部件和机组辅助设备说明5.安装说明6.压缩机的拆卸与装配7.压缩机的主要装配间隙8.压缩机的运转和操作9.压缩机的计划检修10.压缩机常见故障及处理方法11.压缩机的油封和启封12.备件清单13.专用工具14.整体导向环热套规程1.概述ZW-64/35型氧气压缩机为立式、四级四列、双作用、水冷却、无润滑、活塞式氧气压缩机。

可用于大中型空分设备和石油化工等其它工业部门。

该机主要特点为:a.结构紧凑、占地面积小、重量轻。

b.动力平衡性好、运转平稳可靠。

c.振动和噪音小。

d.运行经济性好。

e.导向环、活塞环、填料磨损均匀、寿命长。

f.外形美观。

3.各系统说明请参阅6235LC流程图3.1 气体系统低压氧气,经吸入滤清器过滤,再经各级压缩及冷却后,送入后装置。

具体走向如下:吸入滤清器→一级气缸压缩→一级排气缓冲器→一级换热器→二级吸气缓冲器→二级气缸压缩→二级排气缓冲器→二级换热器→三级进气缓冲器→三级气缸压缩→三级排气缓冲器→三级换热器→四级进气缓冲器→四级气缸压缩→四级排气缓冲器→后续装置。

四级排气缓冲器后设有排气截止阀及放空阀,放空阀为气体紧急放空、吹除及试车用。

3.2冷却系统通往一台压缩机组(主机和各换热器)的冷却水来自一根上水总管。

然后由进水总管分七条支管分别连接各级气缸和各换热器进水口。

其中DN50支管三条,分别接到各换热器进水口;DN40支管一条,接油冷却器进水口;DN32支管二条,分别接到一、四级气缸和二、三级进水口;DN15支管一支,接四级填函进水口。

各排水管管径分别与各自对应的进水管管径相同,各级排水管上均设有测温装置,各进水管和各排水管用的地沟均由用户根据需要和现场位置自行设计,冷却水管全部采用钢管。

3.3润滑油系统由于导向环、活塞环和填料采用自润滑材料,因此气缸不需要注油润滑,只需润滑其它运动部件,该任务由本机组的齿轮油泵来完成。

2BE1系列水环真空泵及压缩机 使用说明书

2BE1系列水环真空泵及压缩机   使用说明书

2BE1系列水环式真空泵及压缩机说明书地址:山东省烟台市福山高薪技术产业区鑫海街188号电话:+86-535-6302098 6300668传真:+86-535-6300568邮编:2655002BE1系列水环式真空泵及压缩机用途及特点:2BE1系列水环式真空泵及压缩机,是我公司在多年科研成果和生产经验的基础上,结合国际同类产品先进技术,研制开发的高效节能产品,通常用于抽吸不含固体颗粒,不溶于水,无腐蚀性的气体,以便在密闭容器中形成真空和压力。

通过改变结构材料,亦可用于抽吸腐蚀气体或以腐蚀性液体作工作液。

广泛用于造纸、化工、石化、轻工、制药、食品、冶金、建材、电器、洗煤、选矿、化肥等行业。

本系列泵采用单级单作用的结构形式,具有结构简单、维修方便、运行可靠、高效节能的优点,并能适应排水量大,载荷冲击波动等恶劣工况。

我们对关键部件,如分配板,叶轮和泵轴进行了系统优化设计,简化了结构,提高了性能,实现节能。

采用焊接叶轮,叶片一次冲压、成形,型线合理;轮毂全部加工,从根本上解决了动平衡问题。

叶轮与泵轴采用热装过盈配合,性能可靠,运行平稳。

叶轮焊接后,整体进行良好的热处理,叶片具有良好的韧性,使叶片的抗冲击,抗折弯能力得以根本保证,能适应载荷冲击波动的恶劣工况。

2BE1系列泵,自带气水分离器,多位置设有排气口,泵盖高有排气检修窗口,叶轮与分配板间隙通过定位轴承两端压盖调整,安装使用方便,操作简单,便于维修。

型号表示方法工作原理:叶轮偏心地装在接近圆形的泵体内,当叶轮按图示箭头方向旋转时,因离心力的作用注入泵内的液体被甩向泵体内壁,形成一个形状与泵体相似,厚度接近相等的液环。

随叶轮一起旋转的液环内表面与叶轮轮毂之间形成一个月牙形空间,当叶轮由A点转到B点时,两相邻叶片之间所包围的容腔逐渐增大,气体由外界吸入。

当叶轮由C点转至A点时,相应的容腔由大变小,使原先吸入的气体受到压缩,当压力达到大气压力时,气体被排出。

HowdenCompressorDivisionBrochure压缩机手册

HowdenCompressorDivisionBrochure压缩机手册

P A P I ENGINEERED FOR PERFORMANCE, RELIABILITY AND PROCESS OPTIMISATIONADVANCED COMPRESSOR TECHNOLOGIESHOWDEN COMPRESSOR DIVISIONA UNIQUE HERITAGE AND PASSION FOR COMPRESSION HOWDEN COMPRESSOR DIVISIONHOWDEN COMPRESSOR DIVISION COMPANIES OCCUPY A UNIQUE POSITION IN COMPRESSOR DESIGN AND MANUFACTURING. WE PIONEERED MANY OF THE TECHNOLOGIES THAT THE GLOBAL OIL AND GAS, PETROCHEMICAL, INDUSTRIAL REFRIGERATION, POWER AND CHEMICAL INDUSTRIES NOW RELY ON.Together, Howden Compressor Division companies have supplied more than 50,000 compressors worldwide over a period of almost 100 years, and today have compressors installed in the world’s most demanding and process-critical operating environments.The compressor division is part of the Howden groupof companies, world leaders in air and gas handling engineering. The Howden Group is a division ofColfax Corporation.HOWDEN KNOW HOW• Efficient and reliable technologies based on 150 yearsof engineering research.• Every compressor meets or exceeds local regulationsand industry standards.• All Howden compressors are backed by lifetimeglobal support.HOWDEN OIL INJECTED SCREW COMPRESSOR RANGE PERFORMANCE ENVELOPEHOWDEN COMPRESSORS LTD MADE THE WORLD’S FIRST COMMERCIAL ROTARYTWIN SCREW COMPRESSOR IN THE 1930s, AND TODAY SUPPLIES THE LARGEST ANDMOST VERSATILE RANGE OF OIL INJECTED AND OIL FREE SCREW COMPRESSORS.WITH 35,000 BARE SHAFT UNITS SUPPLIED WORLDWIDE, WE ARE STILL AT THEFOREFRONT OF SCREW COMPRESSOR DEVELOPMENT.VERSATILE OIL INJECTED SCREW COMPRESSOR RANGE FOR ALL APPLICATIONSHOWDEN COMPRESSOR DIVISION MARKETSWRV 163WRV 204WRV 255WRV 321WRV 365WRV 510Oil and Gas Petrochemical/Chemical Industrial Refrigeration Power and IndustrialHOWDEN’S HISTORICAL COMPRESSOR BRANDS Howden Compressors Ltd supplies Oil Injected bare shaft screw compressors through our global network of nominated packagers and distributors. We also offer Oil Free screw compressors as bespoke designed, complete packaged systems supplied through our specialist packaging business Howden Process Compressors.Example of WRV model rangeUp to 75 bar aUp to 5,000 kWUp to 16,000 smUp to 5,000 rpm Example of XRV model rangeCOMPRESSOR SYSTEMSHOWDEN PROCESS COMPRESSORS IS AN EXPERT OEM PACKAGER OF HIGH SPECIFICATION PROCESS GAS SCREW COMPRESSOR SYSTEMS, CUSTOM DESIGNED FOR PROCESS-CRITICAL APPLICATIONS THROUGHOUT THE WORLD. WE HAVE DESIGNED, MANUFACTURED AND SUPPLIED OVER 1,200 COMPLETE PACKAGED SYSTEMS OVER THE PAST 50 YEARS.HOWDEN PROCESS COMPRESSORS ALSO DESIGNS AND MANUFACTURES A RANGE OF HIGH EFFICIENCY TURBO BLOWERS FOR PROCESS AIR APPLICATIONS. OVER 1,250 HOWDEN TURBO BLOWERS HAVE BEEN SUPPLIED WORLDWIDE OVER THE PAST 50 YEARS.Examples of Howden oil injected and oil free process gas screw compressor systems Examples of Howden ‘SG’ Turbo Blower rangeHowden ‘SG’ Turbo BlowerHowden packaged process gas screw compressor system, built to meet or exceed API 619PACKAGED SCREW COMPRESSORS )LIFETIME AFTERMARKET SUPPORT SERVICESHOWDEN’S AFTERMARKET SERVICE TEAMS UNDERSTAND THE DIFFERENT NEEDS OF EACH INDUSTRY SECTOR AND ALWAYS STRIVE TO PROVIDE THE BEST POSSIBLE SOLUTION BOTH FROM A TECHNICAL AND ECONOMIC PERSPECTIVE.MANUFACTURING, SALES AND REGIONAL SPARES, REPAIRS AND SERVICE CENTRESFOR HOWDEN COMPRESSOR PRODUCTS THROUGHOUT THE WORLD•Regional Compressor Sales and Service Centres OVERVIEW OF THE LIFETIME SUPPORT SERVICES AVAILABLE LOCALLY FROM HOWDEN COMPRESSOR REGIONAL SERVICE CENTRES:• Supply of Original Replacement Parts • Compressor Up-grades and Retrofits • Components & Valves Repairs • Field Site Services• Engineering Troubleshooting • Maintenance Contracts • Re-Commissioning • Customer Operator TrainingOUR SERVICES SUPPORT BOTH EXISTING HOWDEN COMPRESSOR PRODUCTS AND LEGACY PRODUCTS,INCLUDING:• Thomassen Piston Compressors • Centrifugal Compressors • Steam Turbines• Burton Corblin ®Piston Compressors • Burton Corblin ®Diaphragm Compressors • Burton Corblin ®Periflow ®Compressors • Burton Corblin ®Pumps • Twin Screw Compressors• Screw Compressor Packaged Systems • Turbo Blowers•Compressor Manufacturing Centres of ExcellenceOriginal Howden replacement partsPASSION FOR COMPRESSIONHowden, founded in 1854, is a world leading supplier of compressors, fans and rotary regenerative heat exchangers for a large range of industrial applications. Whether pre-engineered or custom built for a specific application, our products are known throughout the world for their high levels of performance, reliability and innovation.The combination of our product knowledge with our extensive applications experience, gained by our engineers on sites throughout the world, allows us to provide our customers with full support, from the initial project inception right through to the end of the plant life.Howden BC Compressors Howden Thomassen Compressors Howden Process Compressors Howden Compressors Limited Glasgow, Scotland, UKRenfrew, Scotland, UK Rheden, The Netherlands Nogent, France。

压缩机选型手册(1-49)

压缩机选型手册(1-49)

XU --- 14
M
MM75SE
j
j
!E
UKRÄ~êÖF
!"#$ TRâï
!"# pb
!"#$%&'()*
4
==2)
SSR
!"#$%&'()*+,-
!E
!F
!"# Hp
!"#$%& XF --- 6.9 EP--- 8.6 HP--- 9.7 bar(g) bar(g) bar(g)
XP --- 11.4 bar(g) HXP ---13.8 bar(g)













47 - 57
4-1. 4-2. 4-3. 4-4. 4-5.
!"#$%&'( !"#$% !"#$%

















58 - 80
5-1. 5-2. 5-3. 5-
IR IR IR IR-D IR-ED IR-CD IR-BD IR
!"#$%&'()*+ !"#$%&' !"#$%&' !"#$% !"#$%&' !"#$%&'( !"#$ !"#$%&'(
EDV-2000TM
1
==

智能市场集团有限公司BR140D空气压缩机用户手册说明书

智能市场集团有限公司BR140D空气压缩机用户手册说明书

03597 03/18For service, spare parts or product information, please contact Smart Marketing Group Pty. Ltd. AUST. 1300 660 457 N.Z. 0800 474 876Recyclable CardboardPortable compressor for medium duty DIY task around the homeMODEL NO.BR140DAIR COMPRESSOR MANUALAs soon as you have purchased the compressor, we recommend that you check to make sure it is intact and that you read the operating instructions carefully before using it. The purchase receiptfor this product is to be retained and must be presented if making a claim under the terms of the Smart Marketing Group (SMG) warranty. Bank account statements are not acceptable for proof of purchase.This warranty does not cover compressors intended for hire or use in commercial applications or in commercial premises. The warranty will under no circumstances extend to reimbursement or payment of damages, whether direct, indirect or consequential. The warranty is void if thereis evidence the compressors has been modifiedor tampered with in any way or used with unauthorised accessories without our consent. SMG declines any responsibility or liability whatsoever arising from misuse or abuse, negligent handling of the compressors or if the product has not been installed or failure to comply with the relevant safety, operating, setting and maintenance instructions (see further in this manual).The warranty does not extend to installation or disconnection costs.Any item sent freight forward/collect for repair will be refused. Warranty repairs are free of charge, provided the appliance is delivered to our service department or authorised service agent. The compressor will need to be returned, adequately protected in a box. SMG will not be responsible for any in-transit loss or damage. Assistance under the warranty will only be made available if the request is made to our customer service team on the contact numbers listed below and proof of purchase is provided.This is a repair only warranty you will need to take the compressor to the authorised service agent after contacting our customer service centre.If the product includes various accessories or components, only the defective accessory or component will be replaced or repaired.SMG reserves the right to replace defective parts of the product with parts and components of similar quality, grade and composition where an identical part or component is not available. Products presented for repair may be replaced by refurbished products of the same type rather than being repaired. Refurbished parts may be used to repair the products.Damage caused by third party accessories is not covered under this warranty.Damage caused to attached equipment or third party accessories will not be covered under this warranty.Rust and corrosion are not covered under this warranty.If a warranty fault is found the freight cost willbe credited to the owner. If no fault is found the product will be returned and any costs associated with the service will be charged to the owner. Blockages caused by spider webs, insects, dirt, accumulated dust, incorrect fuel or incorrectly mixed 2-stroke fuel are not covered by warranty. SMG reserves the right to replace or repair the appliance within the warranty period. Parts found to be defective due to a manufacturing default will be replaced free of charge.In the event of SMG choosing to replace the appliance, the warranty will expire at the original date of purchase. If no warranty fault is found the owner will be advised and the product will be returned and any costs associated with the service will be charged to the owner.Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund fora major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. The benefits of this warranty arein addition to any rights and remedies imposedby Australian State and Federal legislation that cannot be excluded.In New Zealand, this SMG warranty is in addition to the conditions and guarantees which are mandatory as implied by the New Zealand Consumer Guarantee Act 1993. For service, spare parts or product information please contact customer service:Australia: 1300 660 457New Zealand: 0800 474 876CONTACT DETAILSSmart Marketing Group Pty Ltd33-35 Lionel Road, Mt. WaverleyVictoria 3149, Australia.Tel (+613) 9543 7266Fax (+613) 9543 9839***********************.auCOMPLETE WARRANTY STATEMENT – COMPRESSORLUBRICATION OF COMPRESSORBefore attempting to operate this air compressor the transport plug must be removed, thrown out and replaced with the oil breather. Check the oil level to ensure the level is to the top of the red dot on the sight glass; refer to page 10 for complete details and diagram. Failure to do these may result in damage to the air compressor and / or injury to the user.PLEASE follow the instructions noted on page 10 on changing the transport plug to the oil breather.ASSEMBLYThis compressor MUST be fully assembled by you prior to use. Failure to do so will result in the warranty being VOID. Failure to fully assemble this compressor may also result in personal injury.MANOEUVRINGWhen moving this air compressor always use the handle to lift slightly and pull/push using the attached wheels. If you must lift this air compressor always use a 2 person lift due to its weight and size. Failure to use 2 person lift may result in personal injury.SAFETYBefore attempting to operate this air compressor the following basic safety precautions should be taken to reduce the risk of fire, electric shock and personal injury. It is important to read the instruction manual and to understand applications, limitations and potential hazards associated with the air compressor. This air compressoris not intended for use by persons (including children)with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.BEWARE OF CHILDREN AND PETSChildren and pets should be kept out of the work area. Children should not be allowed to touch or operatethe air compressor, tools or extension cords. This air compressor is not designed for use by young children or infirm persons without supervision. The air compressor and tools should be kept out of reach of children, preferably stored or locked in a secure cabinet or room when not in use.WORK AREAWork areas and benches should be kept tidy. Cluttered benches and work areas can cause accidents. Floors should be kept clean and free from rubbish. Special care should be taken when the floor is slippery due to sawdust or wax. Always leave sufficient distance, at least 5 metres between the air compressor and the work area, especially when using tools designed for sanding or spraying liquids.WORK ENVIRONMENTDo not expose your air compressor to rain or use in damp or wet conditions. Keep the work area well lit. Always ensure your compressor is level and stable. Using your compressor on unlevel or unstable ground may cause a lack of lubrication and the pump to seize, this damage will not be covered under warranty.GUARD AGAINST ELECTRIC SHOCKAvoid body contact with earthed or grounded surfaces (e.g. pipes and refrigerators).DO NOT OVERLOAD AIR COMPRESSORSThe air compressor will do a better, safer job and give you much better service if it’s used at the duty cycle for which it was designed. The duty cycle will only take effect after the initial (1st ) tank fill for the day. This air compressors duty cycle is 75%. Duty cycle is the proportion of time during which the air compressor is operating compared with not operating. For example a 75% duty cycle could mean after 45 seconds of operation, motor pumping, the air compressor must be left for 15 seconds resting, motor not pumping. When the motor is pumping the attached air tool can not be used. Simple way to understand duty cycle is only use the attached air tool while the compressor is not pumping. Stop using the attached tool as soon as the air compressor starts pumping.USE THE RIGHT TOOLSelect the right tool for the job. Do not use a tool for a job for which it was not designed. Do not force a small air compressor to do the job of a heavy–duty air compressor. Do not use the air compressor for purposes not intended.DO NOT ABUSE THE POWER CORDNever yank or pull on the power cord to disconnect itfrom the mains supply socket. Never carry or pull your air compressor by its power cord. Keep the power cord away from heat, oil, solvents and sharp edges. Regularly check the plug and cord and if damaged have it replaced by an authorised service facility.EXTENSION CORDS AND REELSThis air compressor MUST be plugged directly into a 240V AC wall socket.This air compressor is NOT designed to be run off an extension cord/ lead. If you need extra distance do NOT use an extension cord, USE A LONGER AIR HOSE.The use of extension cords may cause power voltage loss and will result in damage to the motor. This will NOT be covered under warranty.SECURE THE WORK PIECEWhenever possible secure the work piece using clamps or a vice. It is safer than using your hands or feet and leaves both hands free to control the tool.HOT COMPONENTSBeware many of the components will get hot during use. Never touch any of the metal pipes, pump or motor as these may burn.MAINTAIN YOUR AIR COMPRESSOR WITH CAREFollow the instructions for lubricating and changing accessories. Check the air compressor power cord periodically and if damaged have it replaced by an authorised service facility. Keep handles clean, dry and free from oil and grease. Ensure that ventilation slots are kept clean and free from dust at all times. Blocked ventilation slots or air filter can cause overheating and damage to the motor and this will not be covered under warranty.DISCONNECT AIR COMPRESSOREnsure that the air compressor is disconnected from the mains supply when not in use, before servicing, lubricating, making adjustments or when changing any accessories.REMOVE ADJUSTING KEYSAND WRENCHESForm the habit of always checking to see that any adjusting keys or wrenches have been removed from the air compressor or attached air tools before operating.AVOID UNINTENTIONAL STARTINGEnsure that the switch is in the ‘OFF’ position before plugging the air compressor into the mains supply.PROTECT FURNISHINGSIf using the air compressor inside your house, protect furnishings and floors with a suitable dust sheet.FIRE PRECAUTIONSWhen using the air compressor inside your house or workshop general fire precautions should be observed. This means never leaving your air compressor turned on while not in attendance, never cover the air compressor while being used or while still hot from use, never use in areas where a spark may cause a fire, always use in clean areas. As a precaution it is recommended that an expert is consulted on obtaining and using a suitable fire extinguisher.CLEANING YOUR AIR COMPRESSORNEVER UN-ASSEMBLE your air compressor to clean. Always disconnect your air compressor from the mains power supply before you commence cleaning. Always ensure that your air compressor has cooled, about one (1) hour, before cleaning and storing. When cleaning your air compressor use only a damp soft cloth. NEVER use liquid or solvents of any type.27812131491113121516Oil level should be to the top of the red dot on the sight glassas per the labelPIC. 7Slide handleinto tubesPIC. 8RUNNING IN YOUR NEW AIR COMPRESSOR Before running in ensure that the following has been completed:1. The transport plug has been removed and discarded, seepic. 2 page 10.2. The oil breather has been fitted,see pic 4. page 10.3. Oil level is correct, see page 10.4. The air compressor has been fully assembled, see pages10 – 12.Your new air compressor requires running in:1. Plug the power cord into a standard 240V AC powerpoint2. Open the tank drain tap3. Start the air compressor using theON / OFF button4. Run the air compressor for approximately 1 minute This ensures that the air compressor is fully lubricated under no load.After the 1 minute stop the air compressor using the ON/ OFF button. Allow to cool approximately 10 minutes. Recheck the oil level and top up if needed, additional oil, SAE30, not included.Before starting your air compressor again ensure:1. Tank drain tap is closedPositioning your new compressorChoose a location away from your work area and near to a mains power point.NOTE: 1. N ever use an extension lead. Always use a longer air hose2. A lways position compressor on level ground3. A lways position compressor away from work areaso that the inflator does not get covered in dust orpaint - use a longer air hose to ensure inflator isin clean air USING THE AIR COMPRESSORBefore starting run through this simple list:1. Transport plug removed and discarded, see Pic. 2, page10.2. Oil breather fitted, see Pic. 2, page 10.3. Oil level – CORRECT (top of red dot). Please refer todiagram, Pic. 4, page 10.4. Drain tap – open and drain tank5. Drain tap – close fully6. Check power lead for any damage. If damaged havereplaced by an authorised service centre.7. Plug air compressor into a standard 240V 10Amp ACpower point and turn ON.8. Lift the air compressor button to turn ON, see page 12,Pic. 9.9. Allow the air compressor to fill the air tank.10. Turn the air compressor OFF.11. Turn the power point OFF and disconnect the powerlead from the power point.12. Connect your air hose and air tools.13. Reconnect to the power lead to the power point andturn ON.14. Turn your air compressor ON.15. Once turned and you begin using the connected airtools the air compressor will start and stop withoutwarning. This is controlled by the pressure switch.These pressure settings are factory set and should not be changed.Pumping starts at (minimum) 85PSI and stops at (maximum) 115PSI. Once the initial pump up stage has finished you can adjust the outlet air pressure to the tools recommended working pressure.Above accessories and tools Not supplied, purchased separately.PIC. 11Tank pressuregaugePressure RegulatorOutlet nittostyle socket(female)Outlet pressure gaugeDrain Tap SealedORTo close and seal push lever up Right or leftDrain tap opened un-sealedPIC. 13Tank pressuregaugeOutlet nitto style socket (Air Outlet)Outletpressure gaugePARTS DIAGRAMDescription Qty SMG Part No. Cylinder Head195 BRC95CH Oil Breather195 BRC95OB Sight Glass Seal195 BRC95OLSG Part Description Qty SMG Part No. 43Pressure Gauge Small195 BRC95OPG 44One Way Valve195 BRC95OWV 50Handle195 BRC120THNOTES:*Blackridge® is a registered trademark of Super Cheap Auto Pty LtdFor any queries or assistance call Customer ServiceAUST. 1300 660 457 NZ 0800 474 876Hours of operation:Monday to Friday 8.00am - 5.00pm AESTDo not return to place of purchase. Keep your purchase receipt, this willbe required to make any claims under the 12 month warranty.SpecificationsAir Compressor BR140D Voltage 240V AC ~ 50Hz Motor Electric 2.5 HP Wattage 1875W No Load Speed 2800 RPM FAD (Free Air Delivery)135L per minute*Tank Size 30L Duty Cycle 75%Max Tank Pressure 115PSI (8BAR)Outlet Pressure1PSI - 115PSI Adjustable Lubrication Oil Splash Oil TypeSAE30Minimum Generator Size Pure Sine Wave 3500W Noise Rating 80dB@5m Motor/Pump Kicks In 85PSI Pressure Cycle Stops 115PSI Number Of Outlets2。

压缩机使用手册

压缩机使用手册

垫部分地吸收。压缩机上所使用的橡胶垫,应符合以下要求:
1) 能使振动减小 50%以上;
2) 能吸收切向惯性力所产生相应的运动,特别在压缩机启动或停止时。为获得良好
的安装效果,应保证螺母和衬套之间的间隙,使压缩机传到底板上的振动减弱,另外还
规定位置贴上合格标志及其它标志。两箱叠装后,下面垫有木托盘,以便于装卸。 3.2 单台包装
单台包装适用于产品送样检测、向用户提供样机及其它零星供货。压缩机及附件装 入一个小纸板箱内,压缩机用隔板定位,附件装入塑料袋内并封口,放入箱内规定位置。 3.3 附件的包装
附件采用专用纸板箱集装,两箱叠装后,下面垫有木托盘,以便于装卸。
7
加西贝拉压缩机有限公司
压缩机使用手册
压缩机型号 Compressor
Model
表 10 压缩机允许装运的方向
装运方向 Shipment positions
(所示打×的方向请勿使用。position × must not be used)
B-CY BM-CY
ZBT-CY ZBU-CY ZBG-CY
ZBS-CY ZBC-CY ZBH-CY
JM-CY JK-CY
5 压缩机的正确安装
5.1 选用合适的压缩机 用户选用压缩机时,由于要考虑到冰箱或制冷器具的以下特性:最低蒸发温度、制
冷量、制冷剂类型、环境温度、运行电压和频率、电机启动转矩、压缩机冷却方式、额 定电流等,因此应选择正确的压缩机。 5.2 压缩机的开箱
从包装箱中取出压缩机时应小心,压缩机不能倒置或翻倒。吸气管和工艺管应没有 明显的浸油现象,否则会造成焊接不良。另外,油进入吸气消音器,会使效率下降甚至 不能启动,严重时会导致压缩机阀片的损坏。同样,在压缩机底板上安装橡胶垫时,也 不能倒置或翻倒压缩机。

往复式压缩机说明书4M125

往复式压缩机说明书4M125

使用说明书沈阳鼓风机集团4M125-43/20-204-BX4M125(53).SY 有限公司型新氢压缩机共21 页第1 页前言BX系列往复活塞式压缩机产品,是沈阳透平机械股份有限公司应用德国Borsig公司和瑞士Areco公司的引进技术,采用API618及有关标准,并结合本企业多年来的科研结果及成熟经验进行设计制造的,其整机技术水平已达到国际先进水平。

本使用说明书对本产品的性能、结构、及安装使用等方面均进行较详细的介绍,用户在安装使用前应认真仔细阅读、了解,掌握压缩机的结构特点,遵照使用说明书中的规定和要求,进行正确安装、操作和维护,以保证压缩机长期安全可靠地运行。

属本产品成套供货的电机及其它辅助设备和外购元件,其随机提供的使用说明书与本产品使用说明书具有同等效力,用户亦应遵照其规定和要求进行安装使用。

本产品使用说明书中压缩机安装、试车、使用、操作部分的内容,见随机出厂资料中的《BX系列往复活塞式压缩机安装及验收规范》。

感谢用户购买我公司生产的压缩机产品,对于用户在安装使用过程中,发现的产品质量问题和故障,欢迎及时将情况反馈至我公司“技术服务部门”,我们会及时提出处理意见或派员赴现场解决。

通讯地址:沈阳市经济技术开发区开发大路16号甲邮政编码:1101421、用途及总体结构概述4M125-43/20-204-BX型新氢压缩机,是为中国石油化工股份有限公司石家庄炼化分公司150万吨/年渣油加氢处理装置设计制造的,亦适用使用相同介质并符合其压力和气量下的其它工业部门。

本产品为对称平衡型、气缸水冷、压力循环润滑、电机拖动,各列气缸水平布置并分布在曲轴两侧,具有动平衡性好,操作检修方便等优点。

本产品对于气、水、油的压力、温度,设有指示仪表和自动监控仪表装置,能在危险工况下发出报警讯号和停机联锁保护,并设置气体超压安全泄放装置。

本产品是在消化吸收引进技术基础上进一步提高技术水平的新产品,具有设计先进、结构合理、性能可靠、噪声低、振动小、易损件使用周期长等特点。

JB2021B空气压缩机说明书

JB2021B空气压缩机说明书

小木匠JB-2021B直联便携式空气压缩机使用说明书浙江杰豹机械有限公司敬告客户1、本说明书叙述如何操作本公司生产的系列直联便携式空压机,在安装、装配或启动机组之前,应仔细阅读本说明书,在充分了解机组各部分结构、功能和使用保养方法之后,方可对机组进行正确使用和保养,这对延长机器使用寿命并使其处于良好的工作状态是极为重要的。

2、本机不可反转,用户因使用不当造成的损失,或给第三者造成的损失,本公司概不负连带责任。

3、本系列产品属通用机械产品,社会上仿制品较多,不是本公司纯正零件装配的产品造成产品的质量问题,本公司概不负责。

4、由于产品结构的不断改进,一定时期后,本说明书所述内容,将会与实际产品有所出入,公司不负有对已出厂产品进行相应修改和改进义务。

用户可向本公司各服务驻点或直接向本公司技术部门咨询。

第一章前言首先,感谢您选用本公司生产的空压机,希望它能很顺利地为您的生产作出贡献、本公司的产品在出厂前均经过严格的检验与测试,但为了确保空压机能安全可靠地运转及保持其耐久性,所以在使用前,务请您在百忙中抽出一些时间,详细阅读本说明书以便正确地使用和保养。

第二章概述特点系列直联便携式空气压缩机(以下简称空压机),是本公司精心研制的新型供气设备,作为一般用动力气源,具有以下之显著特点:2.1.1先进:采用技术先进的第四代高效压缩机主机,其气阀结构采用舌簧(条状)结构,比传统气阀提高效率8—10%,省电20%。

2.1.2优质:每台主机都经过严格,使技术指标得以确保。

2.1.3安全:具有压力开关、过载保护器,安全阀等多重保护,防止超压运行。

2.1.4方便:整机设计体贴周到,使得其移动灵活,操作简单、维护方便。

2.1.5运转平稳:噪声低,油耗低。

可靠性高,寿命长,维护费用低。

第三章工作原理本系列空气压缩机主机系采照国外先进的技术设计制造,该系列空压机具有轻便,可靠,耐用之特点,是各种风动工具,风动机械理想的动力源。

大金压缩机技术指南手册(B型)

大金压缩机技术指南手册(B型)

压缩机使用手册大金工业株式会社压缩机开发中心第一节大金压缩机概述一、特点:1. 高性能²大金压缩机是一种无余隙(即无冷媒二次膨胀),且运转范围很宽的高效率压缩机。

²在室外低温制热时,柔性结构压缩机有很强的能力。

2. 低噪音、低震动²无吸、排气阀,压缩机吸排气噪音大大降低。

²通过采用高精度,非接触式涡旋盘,压缩机的噪音性能得到进一步的提高。

²在空调系统安装时压缩机无须增加隔音盖板、消音棉。

²由于压缩机的振动小,这样大大提高了管路抗共振、断裂能力。

使空调产品的管路设计可以达到越简单越好。

3. 小型、重量轻²因压缩机筒体径小、细长,从而为室外机的小型、轻量化提供了最佳选择。

²为了节约空间位置设计的灵活性,在原有四脚底盘的基础上新增加了三脚底盘的机型。

使用户有更多的选择。

4. 高可靠性²压缩机零部件数量少、且可靠性极高。

²压缩机能经受热泵系统的极其残酷的试验。

5. 便于使用²压缩机中只有电机的保护装置是内置式,其它保护均由系统匹配。

这样使系统设计人员可以根据需要在系统设置保护,使产品设计者更好的控制使用的压缩机。

二、 构造:电机转子 电机定子 动盘静盘 排气孔 高压腔支 架曲轴 低压腔冷冻机油 油 泵 欧氏机构轴承支架吸气管吸入冷媒排气管三、 产品系列:基本系列为以下7种:四、 部件规格1. 性能:⑴ 按照下表条件进行试验,完全合格:⑵ 冷冻能力、消耗功率、工作电流:应确保在规格书中所规定的冷冻能力、消耗功率、工作电流的±5%以内。

⑶ 起动特性:应按照下列条件进行起动。

⑷ 绝缘电阻:用500V 绝缘电阻表按照GB 方法进行测定,如果充电部和非充电部的绝缘电阻如 下时应为正常。

² 干燥时: 30M Ω以上 ² 冷媒寝入时: 1M Ω以上 ⑸ 耐电压性能:在AC2400V 、历时一秒的条件下,确保其无绝缘损坏。

压缩机使用手册

压缩机使用手册
缩机使用手册
压缩机型号 Compressor
Model
表 10 压缩机允许装运的方向
装运方向 Shipment positions
(所示打×的方向请勿使用。position × must not be used)
B-CY BM-CY
ZBT-CY ZBU-CY ZBG-CY
Earth wire
Earth screw Rubber Washer Sleeve
Capacitor
Ⅳ型接线盒(J 系列专用)
C
S
M
HERMETIC TERMINAL
Ov e rload p ro tec to r P ro tec t or k eep er
C over
C over kee per
P T C s ta rting rela y
C om pres s or
Ru bb e r wa she r S le ev e
On ly for R SC R
C apacitor
5
加西贝拉压缩机有限公司
重锤式启动
表 8 电器接线示意图 PTC 启动
压缩机使用手册
PTC 启动(带运行电容)
1
1
1
2 压缩机供货状态
2.1 电绝缘 压缩机均按国家标准 GB4706.17-2004《家用和类似用途电器的安全 电动机-压缩机
的特殊要求》通过耐高压试验。 2.2 壳体的耐压强度
压缩机壳体均按国家标准 GB4706.17-2004《家用和类似用途电器的安全 电动机-压 缩机的特殊要求》通过耐压试验。 2.3 干燥度
5.3.1 制冷系统中部件的清洁度和较低的含水量是压缩机长期良好运行的重要条件。为

ELLIOTT__压缩机中文技术手册

ELLIOTT__压缩机中文技术手册

控制箱
控制箱安装在机组底座旁,包括控制压缩机运行的电路回路。
控制系统
控制系统是通过进气阀和卸荷阀来调节气体的流量,喘振发生时,控制系
统也可以自动卸荷离开喘振点,控制系统有以下功能:
(1) 机组的启动和停车控制;
(2) 电机电流及进气密度的控制;
(3) 排气压力控制;
(4) 进气节流控制模式;
(5) 间歇性空重车控制模式;
备件
在英文手册第四章中,详尽列出须定期更换的易损件的规格及数量。正常 的维护和库存最低数量的易损件,可使机组维护快捷、紧急抢修的时间极大 地缩短,增加企业生产能力,减少损失,提高效率。
备件的采购
客户向本公司购买备件时,应详细提供以下资料: (1) 设备的型号、系列号或订单合同号;(可参照压缩机的铭牌) (2) 正常维护保养所需备件的明细表及编号; (3) 所需备件名称及数量; (4) 客户自己的详细地址、电话及联系人;
目录
第一章 概述
1-1
简介
1-1
制造厂内测试
1-2
设定值
1-2
机组货运
1-2
存放
1-2
拆箱
1-3
吊运
1-3
区域性服务机构
1-4
备件
1-4
客户培训
1-5
技术手册信息反馈卡
1-5
压缩机机组结构说明
1-5
润滑系统
1-6
冷却水系统
1-6
控制箱
1-6
控制系统
1-6
第二章 设备的安装
2-1
简介
2-1
地基基础
2-1
安装步骤
2-2
可调整安装衬垫
2-2
管路系统

ABC压缩机操作手册(保养部分)

ABC压缩机操作手册(保养部分)

ABC压缩机操作说明书4 OPERATION操作4。

1安全服役确保压缩机在本手册中技术指标下安全运转。

清理压缩机周围区域:—尽可能清除水、油泄漏,排除泄漏原因。

-使工具、油桶、碎布等杂物远离压缩机。

确保冷却水已冷却压缩机。

避免在无冷却水或冷却不充分的情况下使压缩机工作,否则气缸会发生过热。

决不要切断安全阀和允许压缩机在无保护下运转。

除非压缩机已停止运转,并且气缸已无压力下,才能收紧压力容器和气缸上的螺栓、螺丝和螺帽。

如果电机着火,请不要使用水可用CO2气体扑灭。

压缩机运转过程中一旦出现安全阀跳闸,应立即停止机器,查明原因。

压力调节阀工作时安全阀不会起动,这意味着安全阀跳闸是由于压缩机压力调节阀没有工作.当压缩机停止时,确保所有排水管已手动排尽,并且排空水冷系统。

当水冷系统使用蒸汽冷却塔时,建议咨询水处埋专家,避免冷却塔手册中所陈列之危险。

润滑油、汽油、溶剂、废物等易燃物不要靠近压缩机放置。

当保护器动作部件开启时,压缩机不能起动。

4。

2设备操作空气从进口过滤器吸入后,在气缸中压缩,同时压力增大,温度升高。

在HA和HP系列中,压缩气体温度采用冷水冷却。

首先在气缸,然后在冷却器,都有逆流水从外部管道穿过.冷却器产生的冷凝水会从冷却器出口瓶罐中分离出来,这一过程称之为分离过程。

冷凝水可通过手动或自动排水阀排出.如果生产线中会产生冷凝水,或用户需要干燥气体时,必须使用干燥机.可选冷却型(露点:1~3℃),或吸附型(露点:0℃以下),多数情况下选用干冷机就足够了。

冷却水可以运转在开放(当地水网)或封闭的循环系统中。

在后一种情况下,必须采用冷却水塔或风冷机(激冷系统)方式来冷却水。

为了在最佳条件下给用户生产线提供压缩气体,P&I示意图中不仅陈列了所有的设备,而且涵括了全部的压缩工艺流程和进一步处理系统。

同时P&I示意图也列出了诸如压力、温度,……正常运转工作值、安全阀的安全设定值等。

压缩机需要一个储气罐来为自身调节(加载/空载),储存压缩气体.这样当起动设备时能马上满足用户需要.星型-三角型起动:接触器合上,起动装置得电,“星型”起动持续约12秒,压缩机空转(这样可减少起动电流强度),然后转接“三角型”,机器正常运转。

JB2021B空气压缩机说明书

JB2021B空气压缩机说明书

小木匠JB-2021B直联便携式空气压缩机使用说明书浙江杰豹机械有限公司敬告客户1、本说明书叙述如何操作本公司生产的系列直联便携式空压机,在安装、装配或启动机组之前,应仔细阅读本说明书,在充分了解机组各部分结构、功能和使用保养方法之后,方可对机组进行正确使用和保养,这对延长机器使用寿命并使其处于良好的工作状态是极为重要的。

2、本机不可反转,用户因使用不当造成的损失,或给第三者造成的损失,本公司概不负连带责任。

3、本系列产品属通用机械产品,社会上仿制品较多,不是本公司纯正零件装配的产品造成产品的质量问题,本公司概不负责。

4、由于产品结构的不断改进,一定时期后,本说明书所述内容,将会与实际产品有所出入,公司不负有对已出厂产品进行相应修改和改进义务。

用户可向本公司各服务驻点或直接向本公司技术部门咨询。

第一章前言首先,感谢您选用本公司生产的空压机,希望它能很顺利地为您的生产作出贡献、本公司的产品在出厂前均经过严格的检验与测试,但为了确保空压机能安全可靠地运转及保持其耐久性,所以在使用前,务请您在百忙中抽出一些时间,详细阅读本说明书以便正确地使用和保养。

第二章概述特点系列直联便携式空气压缩机(以下简称空压机),是本公司精心研制的新型供气设备,作为一般用动力气源,具有以下之显著特点:2.1.1先进:采用技术先进的第四代高效压缩机主机,其气阀结构采用舌簧(条状)结构,比传统气阀提高效率8—10%,省电20%。

2.1.2优质:每台主机都经过严格,使技术指标得以确保。

2.1.3安全:具有压力开关、过载保护器,安全阀等多重保护,防止超压运行。

2.1.4方便:整机设计体贴周到,使得其移动灵活,操作简单、维护方便。

2.1.5运转平稳:噪声低,油耗低。

可靠性高,寿命长,维护费用低。

第三章工作原理本系列空气压缩机主机系采照国外先进的技术设计制造,该系列空压机具有轻便,可靠,耐用之特点,是各种风动工具,风动机械理想的动力源。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

压缩机使用手册大金工业株式会社压缩机开发中心第一节大金压缩机概述一、特点:1. 高性能²大金压缩机是一种无余隙(即无冷媒二次膨胀),且运转范围很宽的高效率压缩机。

²在室外低温制热时,柔性结构压缩机有很强的能力。

2. 低噪音、低震动²无吸、排气阀,压缩机吸排气噪音大大降低。

²通过采用高精度,非接触式涡旋盘,压缩机的噪音性能得到进一步的提高。

²在空调系统安装时压缩机无须增加隔音盖板、消音棉。

²由于压缩机的振动小,这样大大提高了管路抗共振、断裂能力。

使空调产品的管路设计可以达到越简单越好。

3. 小型、重量轻²因压缩机筒体径小、细长,从而为室外机的小型、轻量化提供了最佳选择。

²为了节约空间位置设计的灵活性,在原有四脚底盘的基础上新增加了三脚底盘的机型。

使用户有更多的选择。

4. 高可靠性²压缩机零部件数量少、且可靠性极高。

²压缩机能经受热泵系统的极其残酷的试验。

5. 便于使用²压缩机中只有电机的保护装置是内置式,其它保护均由系统匹配。

这样使系统设计人员可以根据需要在系统设置保护,使产品设计者更好的控制使用的压缩机。

二、 构造:电机转子 电机定子 动盘静盘 排气孔 高压腔支 架曲轴 低压腔冷冻机油 油 泵 欧氏机构轴承支架吸气管吸入冷媒排气管三、 产品系列:基本系列为以下7种:四、 部件规格1. 性能:⑴ 按照下表条件进行试验,完全合格:⑵ 冷冻能力、消耗功率、工作电流:应确保在规格书中所规定的冷冻能力、消耗功率、工作电流的±5%以内。

⑶ 起动特性:应按照下列条件进行起动。

⑷ 绝缘电阻:用500V 绝缘电阻表按照GB 方法进行测定,如果充电部和非充电部的绝缘电阻如 下时应为正常。

² 干燥时: 30M Ω以上 ² 冷媒寝入时: 1M Ω以上 ⑸ 耐电压性能:在AC2400V 、历时一秒的条件下,确保其无绝缘损坏。

⑹ 运转噪音: 在规格书所规定的值以下。

第二节压缩机使用方法一、使用时注意事项:1. 使用上的限制事项:⑴温度²排气孔温度:150℃以下(可提供排气孔温度测定样件)²排气温度:(冷凝温度+20℃)~125℃以下²油温:80℃以下²电机线圈温度:120℃以下⑵电源²电压:额定电压±10%以下²相间电压不均衡:±2.5%以下²频率变动:额定频率±2%以下⑶压缩机倾斜角度倾斜10°以内。

⑷冷冻油浓度湿运转时的压缩机存油浓度在35wt%以上。

⑸压缩机液面运转过程中,压缩机的液面高度通过压缩机液面镜目视能够确认。

运转过程中,压缩机积油液面高度应确保从压缩机外面底部向上17mm以上(在此高度以上,从液面镜可以看出)当无法确认时,说明没有注油,从而会使压缩机损坏。

⑹油润滑确认在除霜状态和过度条件的全部运转范围内,请确认在轴承润滑油路径终端是否确保了油的润滑。

可提供油润滑确认用压缩机样机。

⑺使用周围温度-15°~60℃(为压缩机周围温度,非外界温度)2. 冷媒系统⑴冷媒的允许填充量:请按规格书中所示值以使用。

在注入超过上记冷媒量的系统中,压缩机会因为液压缩而引起异音、异常振动、涡旋盘受损等现象,或因冷冻机油被稀释而引起轴承损伤。

为此,虽然设置储液器等,其详细情况请参照“热泵应用”。

并且要进一步确认且确保运转中存油浓度在35Wt%以上。

(可提供压缩机存油浓度检测用样机)。

⑵冷媒的充填请从空调液管高压侧进行。

⑶压力试验时(气密性试验等)的逆压差(=吸气压力-排气压力)在1.47Mpa以下。

⑷冷媒允许水分含量液态冷媒中的水分量应在751PPm以下。

3. 其它⑴起动次数:6次/小时以下请确保每次运转时间在2分钟以上,停止时间在3分钟以上。

⑵设置角度:压缩机倾斜10°以下⑶安装曲轴箱加热器(由系统匹配而定)推荐曲轴箱加热器的输出功率为33W使用方法参考热泵空调中的应用事项。

〈安装曲轴箱加热器的优点〉冷媒非常容易溶于冷冻机油中,特别在油温较低情况下更易溶解,如果在大量溶解状态下起动,因油粘度较低,气沫等原因引起的液体压缩上油,从而引起压缩机轴套烧损的可能性非常高。

为此,必须装上曲轴箱加热器,在其停止时,冷冻机油的温度提高到外界温度以上从而防止溶解。

二、 压缩机可运转范围1. 可运转范围:压缩机运转范围如下图所示(各区域的注意点在下页)冷凝温度(℃)蒸发度温(℃)2. 注意事项⑴ 区域1请按第2节1-⑴项的条件使用。

⑵ 区域2在第2节1-⑴项所示使用上的制约条款中尤其要确认以下事项。

²排气孔温度 : 150℃以下 ²电机线圈温度 : 120℃以下 ²油温 : 80℃以下²油浓度 : 第二节3项所示油浓度范围 ⑶ 区域3应确认压缩机油浓度:²油浓度 :所示第2节3项所示浓度范围 ⑷ 区域4严格按照以下条件使用: ²连续运转时间 :10分钟以下²油浓度 :第二节3项所示油浓度范围 ²排气孔温度 :150℃以下 ²电机线圈温度 :120℃以下3. 油浓度范围请在下记油浓度范围内(压缩机积油部)运行油浓度(w t %)0.25吸入压力(wt %)使用可能油浓度范围三、保护装置1. 在进行产品匹配时,请安装以下保护装置:⑴排气管温度保护为防止因过负荷、缺氟等引起排气温度异常上升,应此在排气管口30cm以内安装温度保护器。

排气管温度保护值的设定,请不要超过第二节1-⑴项的温度上限(在排气孔温度,排气温度中优先于排气孔)。

⑵低压压力保护装置为了防止过度的冷媒回收运转等引起的压缩机损伤,在低压压力为0MPa〔0kgf/cm2〕以上动作的低压压力保护装置。

⑶逆相保护装置因为压缩机长时间逆转会导致故障,故禁止反向运转请安装在压缩机未运转时,能够检知并防止电源相序的逆相保护装置。

⑷过电流继电器为了防止电动机过电流(尤其是堵转电流)引起的事故,请安装过电流继电保护器。

⑸高压压力保护器在高压压力异常上升时,为保证系统的安全使压缩机停机,请安装3-2项所示的气密试验压力以下动作的高压压力保护器。

2. 压缩机内藏式保护装置在压缩机内为了保护电机而装的内藏式保护器,将其设定值、注意事项记入下列表中。

四、压缩机使用注意事项1. 在空调机上安装⑴安装²安装防振垫(规格书中附有防振垫图纸)。

⑵配管连接²请使用钎焊焊料²钎焊时为防止配管壁内产生氧化皮,请从吸气管充氮气。

2. 运输过程注意事项通过模拟运输过程的振动试验,测定对配管所发生的应力,根据需要请用临时螺钉等固定压缩机。

五、售后服务维修用机1. 压缩机的填油量²售后服务维修用机是一种提供的特殊用途的专用压缩机。

(油填充量减少300cm3)²售后服务维修用机在订货时,请明确指出;另外,先测量空调残留冷冻机油的量从而确认减少油量的量。

2. 压缩机更换时注意事项²卸取配管应在排掉冷媒之后,用切管机进行。

(禁止用气切割)²应在通风良好的场所进行。

(注意因冷媒泄漏时缺氧)第三节在热泵空调中的应用当涡旋压缩机进行匹配时,对压缩机可靠性影响很大的各个附件的要点简单说明如下:一、贮液筒贮液筒是解决冷媒填充量超过压缩机允许冷媒量的最切实可行的方法。

当冷媒填充量超出压缩机允许冷媒量时,应选择能有充足收集容量的容器。

为了能使残留在下部的积油迅速返回压缩机,应在贮液筒出口配管下部设置回油孔。

油要迅速返回,需要很大的油孔。

但油孔过大,在起动时容易引起液体返回,高压侧没有设置贮液器的产品中,会出现剩余液体残存的情况,为了防止那时压缩机的吸气冷媒不处于湿运转的状态,尽可能选择小一些的油孔。

下表为规格标准,但根据其它的要素有必要进行适当调整。

因此,在决定时要进行充分试验,并确认保证说明书中的条件。

1. 容量的确定方法:⑴. 贮液筒的有效内容积※注1=(产品的冷媒填充量※注2-压缩机允许冷媒量)/1.15※注1:有效内容积:贮液筒内下外罩到贮液筒出管吸入口之间的容积中减掉其中的配管容积。

※注2:产品冷媒填充量=产品出厂时填充量+允许最大联络配管长度的当地填充量。

⑵. 回油孔尺寸标准:按配管径的比例考虑,孔径如下:毛细管节流(各工况气分器中都应有液态冷媒保证与油互溶状态)气分器中只有气态冷媒无法将油带回压缩机。

根据产品样机,进行选定²因制冷、制热或条件变化而引起的必要冷媒差异,而发生的剩余冷媒存留在贮液筒中的产品为了防止湿运转应选择小孔径。

²使用控制阀进行例行过热度控制,并且有意图在产品中不积冷媒应选择大尺寸。

⑷. 综合注意事项即使在⑴的状况下会出现吸气冷媒过热运转条件另外在⑵的场合起动时、除霜时因一时的液体返回而出现积液现象。

因此,应通过运转确认是否有问题,在必要的时,将其调整到适合的大小。

a).连续过热b). 除霜试验c). 起停试验d). 起动试验二、曲轴箱加热器当冷媒填充量超出压缩机允许冷媒量时而设置的曲轴箱加热器。

应参照规格书中的的推荐功率并按下记进行实施。

1. 曲轴箱加热器的接线为了保证只在压缩机停止时通电,因此应与压缩机用开关的B触电连接。

2. 在产品安装说明书、使用说明书等资料中注意事项。

在时间电源关闭要进行运转时,在压缩机运转前,确保通电时间在6小时以上。

事例:在空调初次运转时必需在运转开始6小时以上以前通上电源,如果忽略这一点,会导致压缩机故障。

三、应遵守安全事项(CCIB)绝缘防水四、防振将压缩机固定在空调底板时,应使用标准的防振橡胶垫。

橡胶垫不合格时,由于压缩机振动从而产生振动声音。

或由于固定不稳而产额外的振动力从而导致管路的破损。

五、管路设计(振动和应力)从压缩机底脚和吸、排气管传播振动,如果配管形状和防振材质不适合会引起配管共振、筒体共振,使振动加大,从而导致配管异常振动甚至破坏。

因此,请按下记实施:1. 针对起动时的大的压缩机的起振力为了分散、缓和排气管的应力请考虑贮液管形状和配管形状。

2. 确认配管应力工作时配管应力按以下方法评价,并确保所使用铜材的疲劳曲线的容许应力以下。

⑴. 起动时:最大发生次数(6次/小时)(年间使用时间)³(设计寿命年限)⑵. 例行工作时,最大发生次数无限大⑶. 尤其是应力集中的地方²压缩机连接部的根部²配管弯曲部²贮液器、四通切换阀连接部根部在考虑下记两点的前提下,选择合适的四通切换阀1. 压力损失------尽可能选择小型;2. 最小动作压力------从切换开始到切换结束确保必要的压差。

相关文档