The minimum air clearance of the 35kV power transformer bushing pertains to the minimal distance between the liveponent and the grounded metal enclosure during the transformer's operation. This crucial parameter ensures the safety and dependability of the transformer's function. Air clearance is of utmost significance as it dictates the insulation capabilities and the transformer's capacity to withstand voltage stresses. The minimum air clearance requirements are stipulated by international standards and regulations to guarantee the safety and operational efficacy of the transformer in practical scenarios.
35k飞机的最低空检 V型变压器灌木是指变压器运行期间活体与被锚金属闭塞之间的最小距离。
这一关键参数确保了变压器功能的安全和可靠性。
空气清关极为重要,因为它决定了绝缘能力和变压器承受电压压力的能力。
国际标准和条例规定了最低的空检要求,以保证变压器在实际情况下的安全和运作效率。
When figuring out how much space the live part of a 35kV power transformer bushing needs, you have to think about a few things. First off, the operating voltage makes a big difference – the higher the voltage, the more clearance you need to make sure everything stays insulated and safe. And
then there's the environment it's in – if it's really polluted, that can mess with the insulation and up the chances of a flashover. Oh, and don't forget about the altitude where the transformer will be – higher up, the air's thinner and that can change how much clearance you need too.
当发现35千米的空间时 V型变压器灌木需要,你得考虑一些事情。
操作电压产生很大差异——电压越高,你就越需要确保一切保持绝缘和安全。
接下来是它所处的环境——如果它真的被污染了,那会干扰绝缘,增加闪光的机会。
哦,不要忘记变压器的高度—上升,空气变薄,这可以改变你需要多少许可。
In implementing the minimum air clearance for the live part of the 35kV power transformer bushing, it is imperative to engage in thorough testing and meticulous calculations that are contingent upon specific operational circumstances and environmental variables. This process may necessitate the undertaking of dielectric tests for the purpose of evaluating insulation efficacy under varying voltage stresses, in addition to the consideration of elements such as temperature, humidity, and the presence of contaminants. Engineers and designers must adhere scrupulously to the stipulated minimum air clearance requirements, thereby ensuring the dependable and
secure operation of the transformer while simultaneously upholding conformity with pertinent standards and regulations.
在执行35k型飞机实况部分的最低空中许可时 V型变压器灌木,必须进行彻底的测试和仔细的计算,这取决于具体的操作环境和环境变量。
这一过程除了考虑温度、湿度和污染物的存在等要素外,还可能需要
进行电极测试,以评估在不同电压下绝缘效果。
工程师和设计师必须
严格遵守规定的最低空检要求,从而确保变压器的可靠和安全运行,
同时坚持遵守有关标准和条例。