氯雷他定片含量测定方法的改进

合集下载

自制和原研地氯雷他定片溶出曲线的比较和评价

自制和原研地氯雷他定片溶出曲线的比较和评价

自制和原研地氯雷他定片溶出曲线的比较和评价摘要目的:比较自制和原研地氯雷他定片剂的溶出行为。

方法:根据普通口服固体制剂溶出曲线测定与比较指导原则,采用浆法,高效液相色谱法检测自制和原研片剂分别在pH 1.0、pH 4.5、pH 6.8的缓冲液和水中的溶出度,f2相似因子法比较溶出曲线的相似程度,初步评价其体外释放行为的一致性。

结果:主成分的溶液稳定性良好,自制片剂和原研片剂在不同介质中的溶出曲线均相似,四组f2因子都大于50,符合评价要求。

结论:自制片剂和原研片剂的体外释放度一致。

ABSTRACT Objective:To compare and evaluate the dissolution behaviors between home-made desloratadine tablet and its reference listed drug. Methods:The dissolution of desloratadine tablets was analyzed by an HPLC method according to guiding principles of determination and comparison on dissolution profile of general oral solid preparation. The dissolution of both drugs was determined in buffer solutions at pH 1.0,pH 4.5,pH 6.8 and water,respectively. The degree of similarity of the dissolution curve was compared by similarity factor f2 and then the consistency of the in vitro release behavior was initially evaluated. Results:The solutions containing main components were stable,and the dissolution profiles of both drugs were similar in various types of media (f2 factors>50). The f2 factors were all met the quoted requirements. Conclusion:The in vitro release behavior of both drugs is consistent.KEy WORDS desloratadine tablets;dissolution profiles;consistency;f2 factor地氯雷他定是一種强效、非镇静性的长效组胺拮抗剂,具有选择性地拮抗外周H1受体的作用及抗过敏、抗组胺及抗炎作用,可用于缓解与慢性特发性荨麻疹及过敏性鼻炎相关的症状[1]。

氯雷他定中国药典2010

氯雷他定中国药典2010

氯雷他定中国药典2010氯雷他定片其他应符合片剂项下有关的各项规定(附录I A)。

【含量测定】取本品10片,精密称定,研细,精密称取适量(约相当于氟他胺0. l g),置100ml量瓶中,加流动相适量,振摇使氟他胺溶解,用流动相稀释至刻度,摇匀,滤过,精密量取续滤液5m l,置50m丨量瓶中,用流动相稀释至刻度,摇匀。

照氟他胺含量测定项下的方法测定,计算,即得。

【类别】同氟他胺。

【规格】0.25g【贮藏】遮光,密封,在干燥处保存。

氯雷他定L u le ita d in gLoratadineC22 H23 C1N2 O z382. 89本品为4-(8-氯-5,6-二氢-11?-苯并[5,6]-环庚并[1,2-6]吡啶-11-烯基)-1-哌啶羧酸乙酯。

按干燥品计算,含 C22H23C1N202不得少于99. 0%.【性状】本品为白色或类白色结晶性粉末;无臭。

本品在甲醇、乙醇或丙酮中易溶;在0. lm o l/L盐酸溶液中略溶;在水中几乎不溶。

熔点本品的熔点(附录W C)为133~137°C。

【鉴别】(1)取本品约lO m g,加稀盐酸溶液2m l溶解后,加碘化铋钾试液2~3滴,产生橙黄色沉淀。

(2)取本品适量,加乙醇制成每l m l中约含lO^g的溶液,照紫外-可见分光光度法(附录IV A)测定,在247nm的波长处有最大吸收,在230nm的波长处有最小吸收。

(3)本品的红外光吸收图谱应与对照的图谱(光谱集865图)一致。

【检査】有关物质取本品,用流动相制成每l m l中含 0.2m g的溶液,作为供试品溶液;精密量取1m l,置100m l量瓶中,用流动相稀释至刻度,摇勻,作为对照溶液。

照高效液相色谱法(附录V D)测定,用十八烷基硅烷键合硅胶为填充剂,以磷酸盐缓冲液(取磷酸氢二钾2. 28g,加水800m l使溶解,用磷酸调节p H值至6.0,再加水至1000m l)-甲醇(20 :80)为流动相,检测波长为247nm,理论板数按氯雷他定峰计算不低于2000。

氯雷他定片含量测定方法的改进

氯雷他定片含量测定方法的改进

【 A b s t r a c t 】 O b j e c t i v e T o i m p r o v e t h e m e t h o d o f r t h e c o n t e n t d e t e r m i n a t i o n o f L o r a t a d i n e T a b l e t s . Me t h o d s T h e d e —
I m pr o v e me nt o f c o n t e nt de t e r mi na t i o n o f Lo r a t a d i ne Ta b l e t s
L | U S h u h u a
I n s t i t u t e f o r Dr u g C o n t r o l o f Ch a o y a n g C i t y i n L i a o n i n g P r o v i n c e , Ch a o y a n g 1 2 2 0 0 0 , Ch i n a
r a t a d i n e wa s s y mme t r i c a l a n d me t t h e s t a n d a r d s o f s y s t e m a d a p t a b i l i t y . T h e me t h o d s h o we d a g o o d l i n e a r r e l a t i o n o v e r
0 . 6 3 9 2 0 g 范 围 内与 峰 面积有 良好 的 线性 关 系 ( r=0 . 9 9 9 9 9 , n=6 ) , 高 、 中、 低 3种 浓度 的 平均 加 样 回收 率 为
9 9 . 4 %( R S D=0 . 5 8 %, n=9 ) 。 结论 该 法 结果 准确 可靠 、 重现性 好 , 有 利 于 延长 泵及 色谱 柱 的使 用 寿命 , 可作 为

HPLC法测定氯雷他定片含量

HPLC法测定氯雷他定片含量

·药品鉴定·中国医药导报CHINA MEDICAL HERALD 2011年2月第8卷第4期氯雷他定片用于缓解过敏性鼻炎的有关症状,如喷嚏、流涕和鼻痒以及眼部瘙痒和烧灼感;也用于缓解慢性荨麻疹及其他过敏性皮肤病的症状。

其质量标准不同厂家使用的含量检测方法不一致,本文采用高效液相色谱法测定氯雷他定片中氯雷他定的含量,该方法准确、可靠、专属性强,可用于该药品的质量控制。

1仪器与试药1.1仪器高效液相色谱仪(日本岛津公司),包括LC-10AT vp输液泵、SPD10Avp输液泵、SPD10Avp可变波长紫外检测器、TA-130柱温箱和ANASTAR色谱数据处理系统;兰博牌超声波清洗器HS-3120型;赛多利斯电子天平BP211-D;电子天平ES120J-4H。

1.2试药氯雷他定片(成都永康制药有限公司091101-1、河南九势制药股份有限公司090802、北京星昊医药股份有限公司091001),氯雷他定对照品(中国生物制品检定所,批号为100615-200602,按C22H23ClN2O2计,本品含量为99.8%),乙腈为色谱纯,磷酸二氢钠、磷酸氢二钠和磷酸为分析纯。

2方法与结果2.1色谱条件与系统适应性试验[1-7]色谱柱为Diamonsil C18(200mm×4.6mm,5μm);流动相为乙腈-磷酸盐缓冲液(用磷酸调节pH值至3.0)(70∶30),流速为1.0ml/min,检测波长为247nm,柱温为25℃,进样量为20μl,理论板数不低于2000。

2.2溶液的制备2.2.1对照品溶液的制备精密称取氯雷他定对照品20mg,置于50ml容量瓶中,加流动相溶解并稀释至刻度,摇匀,滤过,精密量取续滤液1ml,置10ml量瓶中,用流动相稀释至刻度,摇匀,作为对照品溶液。

2.2.2供试品溶液的制备取本品20片,精密称定,研细,精密称取适量(约相当于氯雷他定20mg),置于50ml容量瓶中,加流动相溶解并稀释至刻度,摇匀,滤过,制成对照品储备液。

不同厂家氯雷他定片的溶出度考查

不同厂家氯雷他定片的溶出度考查

不同⼚家氯雷他定⽚的溶出度考查
不同⼚家氯雷他定⽚的溶出度考查
崔飙;杨新建;王雷;王桂英
【摘要】⽬的:⽐较4个⼚家⽣产的氯雷他定⽚的体外溶出度.⽅法:采⽤紫外分光光度法测定氯雷他定⽚的含量,依照《中国药典》溶出度测定法第⼆法测定体外溶出度,并进⾏溶出度参数⽅差分析.结果:4个药⼚产品的含量和均匀度,均符合国家药品监督管理局颁发的质量标准,但4个药⼚产品的溶出参数⽐较有显著性差异(P<0.01或P<0.05).结论:各⼚家产品的体外溶出度差异具有统计学意义.
【期刊名称】《天津药学》
【年(卷),期】2007(019)005
【总页数】3页(P24-25,41)
【关键词】氯雷他定⽚;溶出度;紫外分光光度法
【作者】崔飙;杨新建;王雷;王桂英
【作者单位】天津市长征医院,天津,300120;天津市长征医院,天津,300120;天津市长征医院,天津,300120;天津市长征医院,天津,300120
【正⽂语种】中⽂
【中图分类】医药卫⽣
天津药学TianjinPharmacy2007 年 10 ⽉第 J9 卷第 5 期不同⼚家氯雷他定⽚的溶出度考查+崔飙,杨新建,王雷,王桂英 (天津市长征医院,天津300120)摘要⽬的:⽐较 4 个⼚家⽣产的氯雷他定⽚的体外溶出度。

⽅法:采⽤紫外分光光度法测定氯霄他定⽚的含量,依照《中国药典》溶出度测定法第⼆。

氯雷他定片含量测定方法的改进

氯雷他定片含量测定方法的改进

氯雷他定片含量测定方法的改进目的改进氯雷他定片的含量测定方法。

方法采用Kromasil C18色谱柱(4.6 mm×150 mm,5 μm),柱温为室温,流动相为磷酸盐缓冲液(取磷酸氢二钾0.57 g,加水800 mL使溶解,用磷酸调节pH值为6.0,加水至1 000 mL)-甲醇(20∶80),检测波长247 nm,流速为1.0 mL/min,进样体积为10 μL,进样浓度为16 μg/mL。

结果降低进样浓度及流动相中盐的比例后,氯雷他定色谱峰型对称,符合系统适应性要求,进样量在0.031 96~0.639 20 μg范围内与峰面积有良好的线性关系(r = 0.999 99,n = 6),高、中、低3种浓度的平均加样回收率为99.4%(RSD = 0.58%,n = 9)。

结论该法结果准确可靠、重现性好,有利于延长泵及色谱柱的使用寿命,可作为氯雷他定片的含量测定方法。

标签:氯雷他定片;进样浓度;含量测定;回收率氯雷他定片是抗组胺药,用于缓解过敏性鼻炎有关的症状,亦适用于缓解慢性荨麻疹及其他过敏性皮肤病的症状[1-3]。

现行标准用高效液相色谱法测定含量,笔者在检验工作中发现,现行标准的进样浓度偏高,其后果易造成色谱柱超载,且流动相中磷酸盐的浓度偏高[4-5],易损伤仪器和色谱柱,据此本文对现行方法进行了改进:降低进样浓度为原浓度的1/15,降低磷酸盐浓度为原浓度的1/4,实验证明此法可行,可作为氯雷他定片的含量测定方法。

1 仪器与试药Waters 2695-2489高效液相色谱仪;Empower 2工作站;氯雷他定对照品(批号:100615-200602,中国药品生物制品检定所);氯雷他定片(上海先灵葆雅制药有限公司,批号10ERXF1020;山东罗欣药业股份有限公司,批号:110927;海南新世通制药有限公司,批号:110502);甲醇为色谱纯;磷酸氢二钾、磷酸均为分析纯;水为超纯水。

氯雷他定泡腾片的含量和含量均匀度测定

氯雷他定泡腾片的含量和含量均匀度测定

氯雷他定泡腾片的含量和含量均匀度测定目的:建立HPLC法测定氯雷他定泡腾片含量和含量均匀度。

方法:采用HPLC法,色谱柱:Thermo BDS HYPERSIL C18(250 mm×4.6 mm,5 μm);流动相:甲醇-0.02 mol/L磷酸二氢钾溶液(83∶17);检测波长:247 nm;流速:1.0 ml/min。

结果:定量限为0.6 ng,10.0~100.0 μg/ml的范围内线性关系良好(r=0.999 9),平均回收率为99.4%(RSD=0.84%,n=9)。

结论:经方法学试验,该方法灵敏、可靠、简便,可用于该制剂的含量和含量均匀度的测定。

[Abstract] Objective: To establish the HPLC method for the determination on content and content uniformity in Loratadine Effervescent Tablets. Methods: The column of Thermo BDS HYPERSIL C18 (250 mm×4.6 mm, 5 μm) was used; mob ile phase was CH3OH-0.02 mol/L KH2PO4 (83∶17); flow rate was 1.0 ml/min; detection wavelength was 247 nm. Results: The limit of quantification was estimated to be 0.6 ng. The regression equation showed that the sample had a good linear relationship in the range of 10.0-100.0 μg/ml (r=0.999 9). The average recovery was 99.4% (RSD=0.84%, n=9). Conclusion: The method is sensitive, reliable and simple. It is applicable to the determination on the content and content uniformity in Loratadine Effervescent Tablets.[Key words] Loratadine Effervescent Tablets; Content uniformity; HPLC氯雷他定为长效三环类抗组胺药,可通过选择性地拮抗外周H1受体,抑制组胺所引起的过敏性症状,临床主要用于缓解过敏性鼻炎的鼻部或非鼻部症状,如喷嚏、流涕、鼻痒、鼻塞、眼痒及眼部烧灼感,亦适用于缓解慢性荨麻疹、瘙痒性皮肤病及其他过敏性皮肤病的症状及体征[1-2]。

氯雷他定片生产质量控制研究

氯雷他定片生产质量控制研究

氯雷他定片生产质量控制研究路宁;林慧彬;周惠春【摘要】为提高氯雷他定片的质量,从制粒方法、水份、压力等方面进行实验取得良好的效果,总结出最佳的生产工艺.【期刊名称】《黑龙江医药》【年(卷),期】2011(024)006【总页数】2页(P912-913)【关键词】氯雷他定片;脆碎度;制粒;水份;压力【作者】路宁;林慧彬;周惠春【作者单位】青岛双鲸药业,山东青岛266108;山东省中医药研究院,山东济南250014;中国海洋大学,山东青岛266003【正文语种】中文【中图分类】R943片剂脆碎度指标是该剂型最基本的检测指标。

虽然国家药品监督检查部门加大了药品质量的监督检查力度,但作为固体制剂最基本的质量点,往往被企业和质量监督部门忽视。

氯雷他定片为耳鼻喉科及皮肤用药类非处方药药品,主要用于缓解过敏性鼻炎有关的症状,亦适用于缓解慢性荨麻疹、瘙痒性皮肤病及其他过敏性皮肤病的症状及体征。

氯雷他定片在生产过程中经常出现破片、毛片、碎片现象,在铝塑过程中,粉末多,泡罩内发白,影响了美观和质量。

主要质量问题就是氯雷他定片硬度较小,影响脆碎度,出现不合格问题。

为此,我们对该产品的各个质量点进行分析,主要从颗粒、水份、压力等方面考虑,制定出最佳的工艺参数。

1 仪器与材料1.1 仪器:HLSG220A型湿法混合颗粒机、YK160型摇摆式颗粒机、XL250型旋转式颗粒机、GFGQ-100型高效沸腾干燥机、FZ-120B型高速粉碎整粒机、GZPL-32C型全自动高速压片机、YD-2片剂硬度测试仪、CS-1脆碎度测试仪。

1.2 材料:氯雷他定、乳糖、药用淀粉、糊精、50%乙醇溶液等2 方法与结果2.1 实验过程制粒方法有许多种,制粒方法不同,同样的处方不仅所得到颗粒的形状、大小、强度不同,而且硬度、脆碎度、崩解性、溶出度也不同。

目前生产设备有三种不同制粒方法:湿法颗粒机制粒、摇摆式颗粒机制粒、旋转式颗粒机制粒。

对该产品进行了三种制粒的试验,根据生产指令和生产工艺将氯雷他定、乳糖、药用淀粉、糊精等原辅料用湿法混合颗粒机混合三次,每次2.5分钟,用50%乙醇溶液制备软材,用三种不同的制粒设备制粒:混合颗粒机、摇摆式颗粒机、旋转式颗粒机,用高效沸腾干燥机50℃干燥12分钟后,称重;用高速粉碎整粒机18目,频率10HZ整粒,置三维混合机总混25分钟,称重后全自动高速压片机压片,用硬度仪、脆碎度仪检测各项指标。

基于乙二胺四乙酸滴定法测定氯雷他定中氯含量

基于乙二胺四乙酸滴定法测定氯雷他定中氯含量

基于乙二胺四乙酸滴定法测定氯雷他定中氯含量赵慧彬;陈彦文【摘要】目的使用乙二胺四乙酸二钠滴定法测定氯雷他定中的氯含量.方法在1.0 mol/L HNO3溶液中用Ag+离子沉淀Cl-离子,可将大部分金属阳离子分离;然后将AgCl发生反应[2AgCl + Ni(CN)2-4=2Ag (CN)-2+Ni2+ +2Cl-],用乙二胺四乙酸二钠标准溶液置换出Ni2+离子.结果本法测定结果的平均值和相对标准偏差来看,其重现性好,且颜色变化敏锐,收到了良好的实验效果.结论乙二胺四乙酸二钠滴定法可作为氯雷他定中氯含量的测定方法 .【期刊名称】《中国实用医药》【年(卷),期】2010(005)010【总页数】2页(P127-128)【作者】赵慧彬;陈彦文【作者单位】519000,中山大学附属第五医院药剂科;519000,中山大学附属第五医院药剂科【正文语种】中文氯雷他定(Loratadine)为白色结晶性粉末,无臭无味。

用于缓解过敏性鼻炎的有关症状,以及眼部眼痒及烧灼感。

针对氯雷他定中氯含量的测定,目前国内主要采用传统氯含量测定中的莫尔法。

莫尔法是用铬酸钾为指示剂在中性或弱碱性溶液中用AgNO3溶液直接滴定。

测定时若铬酸钾浓度过高,终点将出现过早,且溶液颜色过深,影响终点的观察。

而若铬酸钾浓度过低,终点出现过迟,也影响滴定的准确度,从而造成较大的误差。

为了提高分析结果的准确度,笔者采用了乙二胺四乙酸二钠滴定法的测氯方法。

在 1.0 mol/L HNO3溶液中用 Ag+离子沉淀 Cl-离子,可将大部分金属阳离子分离;然后将 AgCl发生反应(2AgCl+Ni(C=2Ag(C++2Cl-),用乙二胺四乙酸二钠标准溶液置换出离子。

从本法测定结果的平均值和相对标准偏差来看,其重现性好,且颜色变化敏锐,收到了良好的实验效果。

1 实验部分1.1 主要试剂乙二胺四乙酸二钠标准溶液:0.02mol/L,称取 4.0 g乙二胺四乙酸二钠盐于 400m l烧杯中,加入 200 ml乙醇溶液,使其完全溶解,并稀释至 500 ml,摇匀后在pH≈9.5的氨性缓冲溶液中,以紫脲酸铵为指示剂,用基准试剂Ni(NO3)2· 6H2 O标定其浓度;AgNO3溶液:85 g/L;HNO3溶液(1∶5);紫脲酸铵指示剂:0.1 g紫脲酸铵与 10 g纯 NaCl研细混匀。

紫外分光光度法测定去羧氯雷他定片的含量

紫外分光光度法测定去羧氯雷他定片的含量

紫外分光光度法测定去羧氯雷他定片的含量蔡春阳(安徽双鹤药业有限公司,芜湖 241200)摘要 目的 研究去羧氯雷他定的含量测定方法,为去羧氯雷他定制剂的质量控制提供依据和参考。

方法 将去羧氯雷他定样品于200~400nm进行扫描,并进行稳定性、加样回收、重现性实验。

结果 最大吸收波长为282nm,样品在8h内稳定, RSD为0131%,回收率为99167%,RSD为0132%,重现性良好。

结论 本法用于去羧氯雷他定含量测定,简捷、快速、可靠,较适用于生产过程中的质量控制。

关键词 去羧氯雷他定;紫外分光光度法Determination of desloratadine tablets by UVCA I Chun2Yang(A nhui S huanghe Pharm aceutical L ,W uhu 241200)ABSTRACT AIM To study a method for the content of desloratadine in desloratadine tablets in order to offer reference for the con2 trol of quality in preparation.METH ODS To scan the sample solution in the wavelength200~400nm and determinate the recovery of standard addition,reproducty and stability.RESU LTS The large absorbability wavelength was at282nm.The sample solution was stability in8h.(RSD:0131%)The average recovery rate was99167%with relative standard deviation of0132%.CONC L U2 SION The method was reproducible,rapid,simple and accurate,and it can be used to control the quality of the preparation.KEY WORDS desloratadine;UV 去羧氯雷他定(Desloratadine)为非镇静剂型抗过敏药物[1],是第二代组胺H1受体拮抗剂,对慢性季节性鼻炎、常年性鼻炎、慢性荨麻疹,接触性皮炎及皮肤瘙痒有显著治疗及缓解作用,且心脏毒性低[2,3]。

高效液相色谱法测定氯雷他定颗粒剂的含量

高效液相色谱法测定氯雷他定颗粒剂的含量

高效液相色谱法测定氯雷他定颗粒剂的含量
柏学东;崔志红;王兆钦
【期刊名称】《中国药业》
【年(卷),期】2008(017)009
【摘要】目的用高效液相色谱(HPLC)法测定氯雷他定颗粒剂的含量.方法采用Agilent XDB-C18色谱柱,以磷酸调节pH=2.5的0.05mol/L磷酸二氢铵溶液-乙腈(1:1)为流动相,检测波长245 nm.结果氯雷他定质量浓度在0.01~0.1 mg/mL 范围内与峰面积线性关系良好,平均回收率为100.08%,RSD=0.30%(n=5).结论HPLC法简便、准确,可用于氯雷他定颗粒剂的质量控制.
【总页数】2页(P27-28)
【作者】柏学东;崔志红;王兆钦
【作者单位】鲁南制药集团股份有限公司,山东,临沂,276006;鲁南制药集团股份有限公司,山东,临沂,276006;鲁南制药集团股份有限公司,山东,临沂,276006
【正文语种】中文
【中图分类】R927.2;R976
【相关文献】
1.高效液相色谱法测定复方锌布颗粒剂中马来酸氯苯那敏的含量及含量均匀度 [J], 冯璐
2.高效液相色谱法测定氯雷他定胶囊的含量 [J], 孙大赢;张传霞
3.高效液相色谱法测定参斛颗粒剂中丹参酮ⅡA与丹酚酸B的含量 [J], 褚克丹;季国路;施红;李煌;张玉琴
4.高效液相色谱法测定消炎利胆颗粒剂中大黄素的含量 [J], 何静;高军;安晔
5.高效液相色谱法测定罗纽霉素颗粒剂的含量 [J], 李艳秋;江志强
因版权原因,仅展示原文概要,查看原文内容请购买。

HPLC法检查氯雷他定及其制剂的有关物质

HPLC法检查氯雷他定及其制剂的有关物质

HPLC法检查氯雷他定及其制剂的有关物质
赵亚萍
【期刊名称】《中国药品标准》
【年(卷),期】2003(4)3
【摘要】目的:采用HPLC法检查氯雷他定及其制剂(片剂、胶囊、颗粒剂)的有
关物质.方法:采用Diamonsil C_(18)(5μm,200mm×4.6mm)色谱拄,流动相:乙腈—0.05moL.L~(-1)磷酸二氢铵(用磷酸调pH为2.5)(50:50),检测波长
245nm,柱温:40℃,流速:1.0mL.min~(-1)。

结果:在0.125mg·mL~(-1)~1.25mg·mL~(-1)浓度范围内呈良好的线性关系,回归方程Y=1751C+50,
相关系数,=0.99998,最低检测浓度80μg·m~(-1),最低检测量1.6ng。

结论:方法简便,快速,准确;可同时分离和测定氯霄定原料及其制剂的有关物质。

【总页数】4页(P56-59)
【作者】赵亚萍
【作者单位】湖北省药品检验所,武汉,430064
【正文语种】中文
【中图分类】R9
【相关文献】
1.HPLC法测定地氯雷他定有关物质 [J], 张羽强
2.HPLC法测定福多司坦原料药及其制剂中有关物质的含量 [J], 郭志渊;赵欣庆;朱恒怡;袁军
3.HPLC法测定氯雷他定口崩片的有关物质及含量 [J], 刘晶晶;梁爱仙;李筱玲;钟丹敏;刘敏;李玉兰;王铁杰
4.HPLC法测定地氯雷他定中的有关物质 [J], 李龙;郭伟;于秀丽;解春文
5.HPLC法测定复方制剂厄贝沙坦氢氯噻嗪片有关物质 [J], 赵翠;徐宝燕;兰公剑因版权原因,仅展示原文概要,查看原文内容请购买。

改良HPLC法测定人体血浆氯雷他定水平

改良HPLC法测定人体血浆氯雷他定水平

改良HPLC法测定人体血浆氯雷他定水平
丁永娟
【期刊名称】《山东医药》
【年(卷),期】2011(51)3
【摘要】@@ 氯雷他定为新一代抗组织胺药物,在治疗剂量范围内几乎无明显神经系统毒副作用.目前关于氯雷他定水平的测定方法有放射免疫法、化学发光法、气相色谱法、高效液相色谱法(HPLC)等,但均存在不足之处.2010年1月,我们采用改良HPLC法对人体血浆中氯雷他定质量浓度进行测定,效果满意.现报告如下.
【总页数】1页(P108)
【作者】丁永娟
【作者单位】苏州大学附属第四医院,江苏无锡,214062
【正文语种】中文
【相关文献】
1.HPLC法测定人体血浆中异环磷酰胺及环磷酰胺的浓度 [J], 黎远冬;张炜炜;梁宁生
2.HPLC法测定人体血浆中哌拉西林的浓度 [J], 邓国彬;朱健春;戎清清;董伟林
3.RP-HPLC法测定人体血浆中罗红霉素的浓度 [J], 刘志勇
4.HPLC-MS/MS法测定人体血浆中格列美脲及其活性代谢物 [J], 李婷;南峰;陈枳潓;余勤;向谨;秦永平;谢琨;梁茂植;晁若冰
5.HPLC/MS法测定人血浆中氯雷他定的浓度及人体生物等效性 [J], 李丹毅;陈晓辉;毕开顺
因版权原因,仅展示原文概要,查看原文内容请购买。

2种氯雷他定片剂的人体相对生物利用度试验

2种氯雷他定片剂的人体相对生物利用度试验

2种氯雷他定片剂的人体相对生物利用度试验刘玲;姜宁【期刊名称】《中国药房》【年(卷),期】2006(17)7【摘要】目的:比较2种氯雷他定片(LORAX和LORAS)在人体的相对生物利用度.方法:22名健康男性志愿者交叉单剂量(20mg)口服LORAX片或LORAS片,高效液相色谱法测定其血浆中氯雷他定浓度,3p97程序计算药动学参数.结果:LORAX片和LORAS片的t1/2 Ke分别为(3.03±0.98)h、(2.65±0.81)h;Cmax为(8.59±6.70)、(9.59±8.22)ng/ml;tmax为(1.08±0.41)h、(1.21±0.28)h;AUC(0~t)为(27.29±24.54)、(27.92±20.64)(ng·h)/ml;LORAX的相对生物利用度为(100.63±14.27)%.结论:2种氯雷他定片具有生物等效性.【总页数】2页(P518-519)【作者】刘玲;姜宁【作者单位】重庆市急救医疗中心药剂科,重庆市,400014;重庆市急救医疗中心药剂科,重庆市,400014【正文语种】中文【中图分类】R976;R97【相关文献】1.氯雷他定胶囊和片剂的药动学及相对生物利用度 [J], 杨永革;姜楠;王玉荣;王虎军;徐娟;梅巍2.孟鲁司特钠药动学及其国产片剂/咀嚼片剂人体相对生物利用度研究 [J], 张相林;李凯鹏;丁庆明;刘晓;王辉3.复方氯雷他定缓释片中硫酸伪麻黄碱的人体相对生物利用度和药动学研究 [J], 卢荐生4.马来酸氯苯那敏片剂在健康人体内的相对生物利用度探讨 [J], 刘秀玉5.氯雷他定的片剂及胶囊在人体内的相对生物利用度 [J], 邹远高;苗佳;秦永平;梁德荣;梁茂植因版权原因,仅展示原文概要,查看原文内容请购买。

氯雷他定血药浓度的HPLC荧光检测法及生物等效性研究(英文)

氯雷他定血药浓度的HPLC荧光检测法及生物等效性研究(英文)

氯雷他定血药浓度的HPLC荧光检测法及生物等效性研究(英文)徐晓杰;尚尔鑫;裘福荣;冒国光;相秉仁【期刊名称】《药学学报》【年(卷),期】2004(39)2【摘要】目的建立高效液相色谱法荧光检测血浆中氯雷他定 (loratadine)含量的方法 ,以评价氯雷他定的相对生物利用度。

方法色谱柱为AlltechC18,46mm× 150mm ;流动相为乙腈水冰醋酸三乙胺(90∶10 0∶6∶0 15) ;流速为1mL·min- 1;荧光检测器测定波长 ,Ex=2 74nm ,Em=450nm。

结果HPLC测定线性范围为 0 2~3 0 μg·L- 1,最低定量限0 2 μg·L- 1,方法回收率为 96%~ 98%。

人体生物利用度结果表明 ,实验片、胶囊与对照片间的AUC ,Tmax,Cmax和T1 2 β均无显著性差异 (P >0 0 5) ,两者的相对生物利用度分别为10 7%± 17%和 100 %± 14 %。

AUC和Cmax经可信区间法检验生物等效。

结论【总页数】4页(P123-126)【关键词】氯雷他定;抗变态反应药;血药浓度;高效液相色谱法;荧光检测;生物等效性【作者】徐晓杰;尚尔鑫;裘福荣;冒国光;相秉仁【作者单位】中国药科大学分析测试中心;皖南医学院弋矶山医院国家药品临床研究基地【正文语种】中文【中图分类】R976;R969.1【相关文献】1.HPLC-荧光法测定坎地沙坦血药浓度及坎地沙坦酯制剂的生物等效性研究 [J], 张乐;周世文;徐颖;应懿;黄永平;汤建林因版权原因,仅展示原文概要,查看原文内容请购买。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

氯雷他定片含量测定方法的改进
[摘要] 目的改进氯雷他定片的含量测定方法。

方法采用kromasil c18色谱柱(4.6 mm×150 mm,5 μm),柱温为室温,流动相为磷酸盐缓冲液(取磷酸氢二钾0.57 g,加水800 ml使溶解,用磷酸调节ph值为6.0,加水至1 000 ml)-甲醇(20∶80),检测波长247 nm,流速为1.0 ml/min,进样体积为10 μl,进样浓度为16 μg/ml。

结果降低进样浓度及流动相中盐的比例后,氯雷他定色谱峰型对称,符合系统适应性要求,进样量在0.031 96~0.639 20 μg范围内与峰面积有良好的线性关系(r = 0.999 99,n = 6),高、中、低3种浓度的平均加样回收率为99.4%(rsd = 0.58%,n = 9)。

结论该法结果准确可靠、重现性好,有利于延长泵及色谱柱的使用寿命,可作为氯雷他定片的含量测定方法。

[关键词] 氯雷他定片;进样浓度;含量测定;回收率
[中图分类号] r927.2 [文献标识码] a [文章编号] 1674-4721(2013)02(c)-0076-03
氯雷他定片是抗组胺药,用于缓解过敏性鼻炎有关的症状,亦适用于缓解慢性荨麻疹及其他过敏性皮肤病的症状[1-3]。

现行标准用高效液相色谱法测定含量,笔者在检验工作中发现,现行标准的进样浓度偏高,其后果易造成色谱柱超载,且流动相中磷酸盐的浓度偏高[4-5],易损伤仪器和色谱柱,据此本文对现行方法进行了改进:降低进样浓度为原浓度的1/15,降低磷酸盐浓度为原浓度的1/4,实验证明此法可行,可作为氯雷他定片的含量测定方法。

1 仪器与试药
waters 2695-2489高效液相色谱仪;empower 2工作站;氯雷他定对照品(批号:100615-200602,中国药品生物制品检定所);氯雷他定片(上海先灵葆雅制药有限公司,批号10erxf1020;山东罗欣药业股份有限公司,批号:110927;海南新世通制药有限公司,批号:110502);甲醇为色谱纯;磷酸氢二钾、磷酸均为分析纯;水为超纯水。

2 方法与结果
2.1 色谱条件
色谱柱:kromasil c18(4.6 mm×150 mm,5 μm);流动相:磷酸盐缓冲液(取磷酸氢二钾0.57 g,加水800 ml使溶解,用磷酸调节ph值为6.0,加水至1 000 ml)-甲醇(20∶80);流速:1.0 ml/min;柱温:室温;检测波长:247 nm;进样体积为10 μl;理论塔板数以氯雷他定峰计算不低于2 000;拖尾因子:1.02;氯雷他定与相邻杂质峰之间的分离度均大于1.5。

2.2 溶液的制备
2.2.1 对照品贮备溶液精密称取氯雷他定对照品6
3.92 mg,置100 ml容量瓶中,加流动相溶解并稀释至刻度,摇匀,即得。

2.2.2 对照品溶液精密量取对照品储备溶液25 ml,置100 ml 容量瓶中,加流动相稀释至刻度,摇匀,精密量取5 ml,置50 ml 容量瓶中,加流动相稀释至刻度,摇匀,即得。

2.2.3 供试品溶液取供试品20片,精密称定,研细,取细粉适
量(约相当于氯雷他定10 mg),精密称定,置50 ml量瓶中,加流动相适量,振摇溶解,加流动相稀释至刻度,摇匀,滤过,精密量取续滤液2 ml,置25 ml容量瓶中,加流动相稀释至刻度,摇匀,即得[6-8]。

2.3 专属性试验
取氯雷他定片细粉4份(每份约相当于氯雷他定10 mg),分别经以下条件处理:(1)加入1.0 mol/l的盐酸溶液5 ml破坏后,再加入1.0 mol/l的氢氧化钠溶液5 ml中和至中性;(2)加入1.0 mol/l的氢氧化钠溶液5 ml破坏后,再加入1.0 mol/l的盐酸溶液5 ml中和至中性;(3)在电炉上直火加热至片粉显微棕色;(4)经4 000 lx光照24 h。

取上述经酸、碱、强热及光照破坏的产物,照“2.2.3”项下制备供试品溶液,记录色谱图。

结果表明:氯雷他定与各降解产物分离良好,分离度均大于1.5。

见图1、2、3、4、5。

2.4 线性关系考察
精密量取对照品储备液25 ml,置100 ml容量瓶中,加流动相稀释至刻度,摇匀,分别精密量取1.0、2.0、5.0、10.0、15.0和20.0 ml,分别置于50 ml容量瓶中,加流动相稀释至刻度,摇匀。

进样10 μl,测定峰面积。

以进样量(μg)为横坐标x、峰面积为纵坐标y绘制标准曲线,得回归方程为y = 2 296 747.35x - 715.40,r = 0.999 99(n = 6)。

表明氯雷他定进样量在0.031 96~0.639 20 μg范围内与峰面积有良好的线性关系。

2.5 精密度试验
取对照品溶液,按“2.1项下方法”连续重复进样5次,考察峰面积变化,结果rsd值为0.20%,表明仪器的精密度良好,能满足测定要求。

2.6 稳定性试验
取同一批供试品溶液,在室温条件下放置,分别在0、4、8、12、24 h测定,平均峰面积为365 430,rsd值为0.31%(n = 5)。

表明供试品溶液至少在24 h内稳定。

2.7 重复性试验
取同一批号的氯雷他定片(批号:10erxf1020),按“2.2.3”项下制备供试品溶液5份,依法测定,rsd值为0.45%(n = 5),表明该方法重复性良好。

2.8 回收率试验
精密称取已知含量的氯雷他定片(批号:10erxf1020)细粉适量(相当于氯雷他定5 mg)9份,分为3组,每组分别精密加入对照品贮备液6、8、10 ml,配成低、中、高3个浓度,按“2.2.3”项下制备供试品溶液,测定回收率。

见表1。

2.9 样品测定
取对照品溶液、供试品溶液各10 μl,进样测定,记录色谱图,按外标法计算含量。

本法与现行方法测定结果进行比较,结果显示,两法的测定结果基本一致。

见表2。

3 讨论
3.1 进样浓度的选择
高效液相色谱分析中,进样量不宜过大,以免色谱柱超载或检测器超限,本法选用“2.4”项下标准曲线的中间浓度为进样浓度,响应值的重现性良好。

本法的浓度用岛津uv-2550紫外分光光度计测定,吸收度约为0.6,而现行标准测定浓度的吸收值因检测器超限而无法显示数据。

3.2 流动相的选择
《中华人民共和国药典》2010年版二部新增关于流动相的选择原则是:应尽可能少用含有缓冲液的流动相,必须使用时,应尽可能选用含较低浓度缓冲液的流动相[9]。

笔者曾选用不加盐的流动相甲醇∶水(80∶20)、乙腈∶水(80∶20)进行考察,结果显示主峰不为分离峰;分别用现行方法及本法的高、低两种磷酸盐浓度进行比较,色谱峰除保留时间有差异外,分离效果均良好,故选用低浓度的缓冲盐溶液作为流动相,将缓冲盐溶液给仪器和色谱柱带来的损害降至最低;本研究还曾选用乙腈代替本法流动相中的甲醇进行试验,柱效及峰高虽提高至原来的2倍,但考虑到本法已经达到系统适用性的要求,且乙腈的毒性和成本较大,所以不建议使用。

3.3 专属性
经破坏试验验证,本法的氯雷他定主峰与降解产物达到良好的分离,能够排除降解产物的干扰,专属性强且峰型良好,拖尾因子为1.02,可以有效地控制氯雷他定片的质量。

本法测定氯雷他定片的含量,具有较宽的线性范围和较高的回收
率,结果可靠、准确、重现性好,色谱条件符合系统适用性要求,有利于延长泵及色谱柱的使用寿命,与现行方法测定结果比较,两法的测定结果基本一致,可以作为氯雷他定片的含量测定方法。

[参考文献]
[1] 方克忠. hplc法测定氯雷他定片的含量[j]. 齐鲁药事,2012,31(2):88-89.
[2] 崔京,黄健,霍立茹,等. 氯雷他定片含量及有关物质的hplc 测定[j]. 中国医药工业杂志,2002,33(6):294-295.
[3] 康军,张鹤. hplc法测定氯雷他定片含量[j]. 中国医药导报,2011,8(4):56-58.
[4] 张德强,柯东华,莫祝容. 氯雷他定糖浆含量及有关物质的hplc测定[j]. 今日药学,2011,21(3):167-169.
[5] 张带荣,周利娟. 高效液相色谱法测定氯雷他定糖浆中氯雷他定含量[j]. 中国医院药学杂志,2007,27(9):1316-1317.
[6] 刘东权,王晓文,陈鑫,等. 氯雷他定泡腾片的含量和含量均匀度测定[j]. 中国医药导报,2011,8(32):55-57.
[7] 孙大赢,张传霞. 高效液相色谱法测定氯雷他定胶囊的含量[j]. 中国药业,2009,18(14):33-33.
[8] 柏学东,崔志红,王兆钦,等. 高效液相色谱法测定氯雷他定颗粒剂的含量[j]. 中国药业,2008,17(9):27-28.
[9] 国家药典委员会. 中华人民共和国药典[s]. 二部. 北京:中国医药科技出版社,2010:29-30.
(收稿日期:2012-12-03 本文编辑:袁成)。