GDS-2000A+Quick+Start+Guide快速入门手册
A2000A便携式合金光谱仪操作指南
便携式合金光谱仪操作指南A2000A一、 各项功能键详解1、FILE(文件):STANDARDIZE(标准化—不用点击);LOAD LIBRARIES(调入数据库—不用点击设定)EXIT (关机退出文档--需要点击此键一步步退出关机)2、EDIT(编辑):EDIT TEST INFORMATION(编辑测试信息—不用点击设定);EDIT GRADE LIBRARIES(编辑等级库—不用设定);MODIFY TESTINFO TEMPLATE(信息模板—不用点击设定)3、VIEW(视图):LIVE UPDATES(动态更新---要点击打勾);RESULT(测定结果—点击此键可查看测试数据的表格)Chemistry(测定完显示结果--要点击打勾,不然测定结束会出现其他画面)4、OPTIONS(功能设定):AL MODE (铝模式—不用点击设定);REPEAT TEST(重复测试-不用点击设定);SET TESTING TIMES(设置测试时间—点击可改变测定时间);EXACT MATCH (精确匹配—不用点击设定)GRADE LIBRARY SETTINGS(等级库设置—不用点击设定)5、Help(帮助—不用点击)二、仪器操作标准程序1、掌上电脑确认A、确认掌上电脑(即PDA)电池电力至少在75%以上;B、确认PDA在有电的情况下,一般PDA可以持续维持电力的时间约4—5天,因此建议每隔4—5天将PDA充电,否则掌上电脑会自动回到原始的出厂时间,此时必须重新设定时间方可正常使用;2、主机开机前确认A、在装入电池前,首先要确认电池在开机时的电量一定要大于两格电量以上,才能保证整机的正常启动;按一下,电池上白点可以看到电池电量;B、确认好电池电量后,将主机打开握柄底座橡胶盖,将电池装入电池槽中,将底座橡胶盖盖紧即可;C、将PDA前端以45度角顶住INNOV-X主机上端介面控制座,将前端往前推;D、将PDA后端平放后,往后推,使PDA上的连接端头与INNOV—X主机介面控制座上的连接端头确实紧密接合,务必要没有间隙完全卡住(重要);(此步骤时敬请小心动作放慢,以免损坏连接头)如下图所示:E 、按住主机后端电源开关3秒钟,绿色电源指示灯亮电源即完成主F 、开启PDA 屏幕上会出现Windows CE的操作界面,如此则完成PDA 的开机动作; 二、 合金检测仪2000型INNOV—X 软件启动步骤详解操作图示操作图示步骤操作说明操作图示步骤操作说明操作图示操作图示三、关机顺序:先一步一步点击File里的Exit(退出)退到最原始的开始页面为止。
Gd2000使用说明
前言GD2000 档案管理系统 V3.0 版是把立卷改革后的归档文件管理与传统的卷内文件管理相结合,既有文书管理,归档管理,又有企事业管理和收发文管理等,使许多尚未完全摆脱传统手工管理的档案工作人员能够使用计算机来进行科学的管理,同时还实现了全文图像管理和批量数据修改,对我区的档案现代化管理进程具有很大的推动作用。
它基于 WINDOWS 操作系统平台,集日常的文书管理、收发文管理、企事业管理、归档文件管理为一体,具有速度快、操作简便、数据安全性强、目录编制灵活、检索功能强大、通用性、适用性强等特点,是一套综合性较强的档案信息现代化管理系统。
为使用户尽快掌握本系统的操作方法和使用技巧,编写了GD2000档案管理系统的使用方法说明书,以最大限度给用户提供方便。
第一章安装之前1、检查包装在您得到GD2000档案管理软件之后,请您仔细地检查包装内容是否完整,如果您发现项目缺少时,请您及时与广西档案服务中心取得联系,以便得到妥善处理。
GD2000 档案管理软件包装盒中包括以下项目:(1)软件使用手册一本(2)软件加密狗一个(3)软件安装光盘一张2、系统运行环境( 1 )硬件环境:机型:PⅢ以上;硬盘:剩余空间不少于1G;内存: 526M 以上( 2 )软件环境:本系统运行在中文 WINDOWS9X/2000/XP/VISTA/7 操作系统下,屏幕分辨率大小为:800*600以上,增强色(16位)以上。
3、技术支持与服务为了向您提供快捷、有效的技术支持与服务,我们准备了热线电话和专门的技术服务人员随时为您提供咨询服务。
技术咨询电话:(0771)588574158523945852503广西档案服务中心电话:(0771)5852557地址:广西南宁市星湖路北一里3号(广西壮族自治区档案局大院内)第二章系统安装1、如果是USB加密狗请在安装完加密狗驱动程序后再插入。
请执行光盘中加密狗目录下的驱动程序:SoftDogInstdrv.exe,安装加密狗驱动程序,选择并口(或USB)驱动(根据屏幕提示安装即可),方能正确使用该软件。
2000系列电流变压器电源测量仪用户快速启动指南说明书
Observe Proper Phase Wiring Phase A CT & Line 1 Voltage Match Phase B CT & Line 2 Voltage Match Phase C CT & Line 3 Voltage Match
C B A
0RA4851000001 REV 1
© 2012 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.
Installation of Voltage Lines Check to make sure service is disconnected before any connections are made.
*Visit /meters for the complete installation manual.
• Turn off all power supplying the equipment before performing any wiring operations. Use a properly rated voltage sensing device to confirm power is off.
Phase Placement 3- Proper Polarity of Conductors at CT Input Terminals
ISOLATED
OUTPUT RS485 10 COM 1K A B
X1 X2 X1 X2 X1 X2 CT3 CT2 CT1
CT INPUTs
Neutral Bus
GDS-2000中文说明书
Declaration of Conformity1目录页数使用前注意事项.......................................................错误!未定义书签。
安全术语与符号 ..................................................错误!未定义书签。
特定注意事项 ......................................................错误!未定义书签。
产品介绍 ..................................................................错误!未定义书签。
包装物品..............................................................错误!未定义书签。
开机......................................................................错误!未定义书签。
功能确认..............................................................错误!未定义书签。
面板介绍 ..................................................................错误!未定义书签。
前面板..................................................................错误!未定义书签。
后面板..................................................................错误!未定义书签。
显示器..................................................................错误!未定义书签。
QuickGuide_ZH_TW说明书
BT-Q1000XT 簡易使用指南繁體中文……………………………………………………………………………………………………………………………………………………………………………………….A. 盒裝標準配備(1) GPS 本體BT-Q1000XT (2) 可充電式鋰電池(3) 車用點煙器式充電器(4) mini USB 連接線+ 保證卡注意: 車用點煙器式充電器為BT-Q1000XT量身訂做的特別規格,所以請勿將其用來與其它設備搭配使用。
1. 2. 3.4.B. 外觀1. 電源插座(mini USB)2. 模式選擇(OFF/NAV/LOG)3. 電源狀態指示燈(紅/綠)4. 藍牙連線狀態指示燈(藍)5. GPS連線狀態指示燈(橙)6. 內建天線7. 景點座標記錄按鈕(POI)Beyond Navigation繁體中文……………………………………………………………………………………………………………………………………………………………………………………….C. 硬體功能模式選擇(OFF) 模式選擇(NAV) 模式選擇(LOG)D. 電池安裝D-1 將電池放入主體:打開主體下方的電池蓋,將電池放入主體後再把電池蓋蓋回原處固定D-2 將電池取出:打開主體下方的電池蓋,然後把電池從主體中取出繁體中文……………………………………………………………………………………………………………………………………………………………………………………….E. 為您的電池進行充電如果您是第一次使用BT-Q1000XT,請將電池完全充電。
將電源線連接電源插座並藉由mini USB線、旅行充電器或車用充電器進行充電。
充電時間約為3小時-當電源指示燈為紅色閃爍,電池將耗盡電源,請進行充電-當電源指示燈為綠色恆亮,電池正在進行充電-當電源指示燈為熄滅,電池電源已充電完畢.F. 設定BT-Q1000XTF-1 安裝USB驅動程式和QTravel PC軟體(支援Microsoft Windows XP / Vista/Win7/8/10)請至Qstarz網站/download.php或https:///Web/DownloadIndex_BTQ.php選擇GPS Travel Recorder> BT-Q1000XT,並下載最新的USB驅動程式和QTravel軟體。
Samsung SPS-2000 SAM4s SPS 2000 Quick Start 引导书说明书
Samsung SPS-2000 quick start ManualSAM4s SPS 2000Quick Start GuideQS-SPS-2000 Manual Revsion 1.4CRS, Inc.Limited Warranty and Disclaimers of WarrantyThis manual has been developed by CRS, Inc. It is intended for the use of its customers and service personnel and should be read in its entirety before attempting to install, use or program the product(s).Nothing contained in this manual shall be deemed to be, and this manual does not constitute, a warranty of, or representation with respect to, the product or any of the products to which this manual applies. This manual is subject to change without notice and CRS, Inc. has no obligation to provide any updates or corrections to this manual. Further, CRS, Inc. also reserves the right, without prior notice, to make changes in equipment design or components as it deems appropriate. No representation is made that this manual is complete or accurate in all respects and CRS, Inc. shall not be liable for any errors or omissions contained in this manual. In no event shall CRS, Inc. be liable for any incidental or consequential damages relating to or arising out of the use of this manual. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied or reproduced without prior written consent of CRS, Inc.NOTICEIF ANY WARRANTY IS EXTENDED TO YOU WITH REGARD TO THE PRODUCT(S) TO WHICH THIS MANUAL APPLIES, IT IS A WARRANTY FROM THE ENTITY OR INDIVIDUAL FROM WHOM YOU DIRECTLY PURCHASED THE PRODUCT(S). SUBJECT TO THE FOREGOING, UNLESS YOU ARE A DIRECT END USER CUSTOMER OF CRS, INC., CRS, INC. DOES NOT EXTEND TO YOU ANY EXPRESS WARRANTY OR ANY IMPLIED WARRANTY AND EXPRESSLY DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR USE, OR FITNESS FOR ANY PARTICULAR PURPOSE, OR ANY WARRANTY OF NON-INFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS IN CONNECTION WITH THE PRODUCT(S) OR ANY SOFTWARE, DRIVERS, OR PROGRAMMING PRODUCT, WHETHER EMBEDDED IN PRODUCT(S) OR PROVIDED AS A SEPARATE PROGRAM, OR USED IN CONJUNCTION WITH THIS/THESE PRODUCT(S). CRS, INC. SPECIFICALLY DOES NOT WARRANT THAT THE OPERATION OF ANY DRIVERS, SOFTWARE, OR PROGRAMMING PRODUCTS LICENSED HEREUNDER, WHETHER EMBEDDED IN PRODUCTS OR PROVIDED AS SEPARATE PROGRAMS, SHALL BE UNINTERRUPTED OR ERROR FREE OR THAT FUNCTIONS CONTAINED IN SUCH DRIVERS, SOFTWARE OR PROGRAMMING PRODUCTS SHALL OPERATE IN COMBINATION(S) WHICH MAY BE SELECTED FOR USE BY YOU OR OTHERWISE MEET YOUR REQUIREMENTS.CRS, Inc. is not responsible for any damages or loss, either direct, indirect, special, incidental or consequential, which you may experience as a result of your purchase or use of the product(s). Your sole remedy in the event that you encounter any difficulties with the product(s) is against the entity or individual from whom you purchased the product(s).Revision 2.0 - April 1, 2005WARNING - U.S.THIS EQUIPMENT GENERATES, USES AND CAN RADIATE RADIO FREQUENCY ENERGY, AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTIONS MANUAL, MAY CAUSE INTERFERENCE TO RADIO COMMUNICATIONS. IT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A COMPUTING DEVICE PURSUANT TO SUBPART J OFPART 15 OF FCC RULES WHICH ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST SUCH INTERFERENCEWHEN OPERATED IN A COMMERCIAL ENVIRONMENT. OPERATIONS OF THE EQUIPMENT IN A RESIDENTIAL AREA IS LIKELYTO CAUSE INTERFERENCE IN WHICH CASE THE USER, AT HIS OWN EXPENSE, WILL BE REQUIRED TO TAKE WHATEVER MEASURES MAY BE REQUIRED TO CORRECT THE INTERFERENCE.NOTICE - CANADATHIS APPARATUS COMPLIES WITH THE CLASS “A” LIMITS FOR RADIO INTERFERENCE AS SPECIFIED IN THE CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO INTERFERENCE REGULATIONS.CET APPAREIL EST CONFORME AUX NORMES CLASS “A” D’INTERFERENCE RADIO TEL QUE SPECIFIER PAR MINISTRE CANADIEN DES COMMUNICATIONS DANS LES REGLEMENTS D’INTERFERENCE RADIO.ATTENTIONThe product that you have purchased may contain a battery that may be recyclable. At the end of its useful life, under various state andlocal laws, it may be illegal to dispose of the battery into the municipal waste system.Check with your local solid waste officials for details concerning recycling options or proper disposal.ContentsIntroduction 5 SAM4s SPS-2000 Overview (5)Hardware (5)Software (5)Options (5)Unbox & Install MCR (6)Power Requirements (6)Terminal Controls & Connections (7)Front Panel Angle Adjustment (7)Rear Display (8)SD Memory Card Slot (8)Connection Panel (9)Default Screen Layout (10)Screen Saver (10)Keylinks (11)Passwords (12)Password Notes (12)Initialize (12)Memory All Clear (13)Software Installation & SD Memory Utilities 15 Overview (15)Required Support Resources (16)SPS-2000 Program Components (17)Installing Software Using the TFTP Server Method (18)A. Download SPS-2000 Software Files (18)B. Set TCP/IP Protocol Options (19)C. Install and Start the TFTP Server (21)D. Install the Updated Software (23)E. Verify Software Version (25)Application Upgrade from SD Card (27)Bootloader Upgrade from SD Card (28)O/S Upgrade from SD Card (29)Capturing SPS-2000 Screens (30)Equipment Required (30)Screen Capture Procedure (30)Image Downloads (31)Tips for Getting Images Ready (31)Image Download Using SD Memory Card (31)Screen Saver Logo (33)Save/Load End User Program Using SD Memory Card (34)Save End User Program (34)Restore End User Program (34)SAM4s SPS-2000 Quick Start Guide v1.4 Contents 3Save Reports (35)Restore Reports (35)Demonstration Program 37 Overview (37)Demo Program Main Screen (37)Operation Information (38)Application Notes (39)Convenience Store (39)Beverage/Coffee/Bakery (39)Ice Cream (39)Chicken (40)Sandwich (40)Salad And Sides (41)Chinese (41)Mexican (41)Pizza (41)Bar And Grill (42)PLU File Structure: (42)Connecting a Demo Printer (43)Hardware Required (43)Program Settings (43)Downloading NV Images to the Demo Printer (46)Manual Revision Record 49 4 Contents SAM4s SPS-2000 Quick Start Guide v1.4。
电能公司电力表2000系列 Quick Start 指南说明书
ContentsDescription PageMechanical Installation . . . . . . . . . . . . . . . . . . . . .1Electrical Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . .2Network Planning . . . . . . . . . . . . . . . . . . . . . . . . .4Locating the Gateway Card . . . . . . . . . . . . . . . . . .5Configuring the Meter’s Gateway Card for Network Accessibility . . . . . . . . . . . . . . . . . . . . . .6Configuring a Fixed IP Address for the Gateway Card using a local PC . . . . . . . . . . . . .6Verify the IP address . . . . . . . . . . . . . . . . . . . . .9Network Access . . . . . . . . . . . . . . . . . . . . . . . . . .9Restarting and Factory Defaults . . . . . . . . . . . . . .9Restart the Gateway Card . . . . . . . . . . . . . . . . .9Additional Information . . . . . . . . . . . . . . . . . . . . .10Power Xpert Meter 2000 SeriesCopyright © 2011 by Eaton Corporation . All rights reserved .Specifications contained herein are subject to change without notice .Power Xpert is a registered trademarks of Eaton Corporation .EATON CORPORATION - CONFIDENTIAL AND PROPRIETARY NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATIONTHIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE PROPERTY OF EATON CORPORATION, AND IS MEREL YON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME . BY TAKING POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOTBE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF EATON, AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON . IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT .DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITYThe information, recommendations, descriptions and safety notations in this document are based on Eaton Electrical Inc . and/or Eaton Corporation’s (“Eaton”) experience and judgment and may not cover all contingencies . If further information is required, an Eaton sales office should be consulted .Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser .THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALL Y SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES . ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON . THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES . In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental or consequential damage or loss whatso-ever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein .PXM 2000 Quick Start GuideMechanical InstallationIM02601002E 1Mechanical Installation 4” Diameter round mounting 92 mm Square Form ANSI Studs 4” Round Form Caution: Do not overtightennuts as this can damage the me-ter. The maximum installationtorque is 0.4 Newton-Meter.92 mm square formUnscrew ANSI studs for DIN InstallationPXM 2000 Quick Start GuideElectrical Wiring2 IM02601002EElectrical WiringNote: Other wiring configurations are available . See the Power Expert Meter 2000 Userand Installation Guide for additional informationWYE Direct 3 Phase, 4-wireWYE with PTs 3 Phase, 4-wirePXM 2000 Quick Start GuideElectrical Wiring IM02601002E 3DELTA Direct 3 Phase, 3-wireDELTA with PTs 3 Phase, 3-wirePXM 2000 Quick Start GuideNetwork Planning4 IM02601002ENetwork PlanningThe hardware for the Power Xpert Meter 2000 family is similar to other EATON IQ 250 and 260 meters except that these meters include an integrated, multi-function Ethernet network gateway card . The Power Xpert Meter 2000 Gateway Card provides many of the features found in the rest of the Power Xpert line of meters, including:• Local web server • Modbus/TCP communitations • SNMP communications • Power Xpert Software (PXS) communications • BACnet/IP communications The Network PC requires a web browser (Internet Explorer versions 7 or 8 are sup-ported) and an installed version 6 or later of the JAVA J2SE JRE (Java Runtime Environ-ment) . If Java is not already installed, you or the network administrator may download it from www .java .com and install it per Sun’s instructions . See the Power Expert Meter 2000 User and Installation Guide for additional information .An Ethernet connection is used for configuring the meter’s gateway card communica-tion settings via a web browser . Y ou may need to contact your network administrator for some network and configuration information . In preparation, you will need to decide if the meter will be manually assigned a fixed (static) IP address or will be automatically assigned a fixed IP address by a DHCP server somewhere on the network . With either method the assigned network address must not change once the meter has been de-ployed . Changing the IP address will cause loss of communication until the associated client PCs change the corresponding meter’s IP addresses .Discuss with your network administrator whether you should manually configure the meter with an assigned IP address or whether the DHCP server will assign one . For the DHCP server to provide a fixed IP address, your network administrator will need to know the MAC address assigned to the meter .H C aution Eaton strongly recommends using a fixed IP address if an Eaton PXS system will be ac-cessing the meter . Otherwise, should the IP address change (after a power outage, for example), PXS will no longer be able to access data from the meter .The MAC address is found on a small label that consists of 14 letters and numbers . It looks something like: 002080850047EF Locate the MAC address on your meter and record it here . MAC Address : ______________________________________________________________Is DHCP going to be used to assign the IP address to your meter? ___ Y es ___ No If Yes : Provide the MAC address to the network administrator and record the fixed IP address the network administrator will assign to your meter in the DHCP server here:IP Address: __________________________________________________________________PXM 2000 Quick Start GuideLocating the Gateway CardIM02601002E 5The card will be configured remotely . Skip to the section entitled Verify the IP addressIf No :Record the following information provided by the network administrator here:IP Address: _________________________________________________________________Subnet Mask: _______________________________________________________________Default Gateway: ____________________________________________________________Primary DNS Server IP Address _______________________________________________Secondary DNS Server IP Address _____________________________________________Locating the Gateway CardFirst, ensure power is applied to the meter .The Power Expert Meter 2000 Gateway Card is the blue card installed in the right-most option slot (slot 2) on the rear of the meter . The card is labeled: Power Xpert GatewayPXM Series 2000 .PXM 2000 Quick Start GuideConfiguring the Meter’s Gateway Card for Network Accessibility6 IM02601002ELocation of Gateway CardThere are four indicator LEDs on the Gateway Card labeled: Status , DHCP , Ident , andPower . When power is first applied all the lights should be off for a few seconds and then the Power light will illuminate . This indicates the card has power and is running .Configuring the Meter’s Gateway Card for Network Accessibility Configuring a Fixed IP Address for the Gateway Card using a local PCY our network administrator provided an IP address, a subnet mask, and a default gate-way (which you entered in the previous section) . This information must be entered into the Gateway Card using a local PC, such as a laptop .This method requires a PC with the following:• an Ethernet port• an Ethernet cable (either straight-through or cross-over)• A web browser such as Internet Explorer 7 or 8• an installed version 6 or later JAVA J2SE JRE (Java Runtime Environment) . If not already installed you may download it from www .java .com and install it . (If Java isn’t installed, you’ll be prompted to install it .)To configure the Gateway Card:1 . On the PC, launch the Java Control Panel screen (available through the WindowsPXM 2000 Quick Start Guide Configuring the Meter’s Gateway Card for Network Accessibility IM02601002E 7Control Panel ) .2 . On the General tab, click the Settings button under Temporary Internet Files .3 . Ensure the Keep T emporary Files on My Computer check box is cleared . 4 . Connect the PC to the Gateway Card through an Ethernet cable (either a straight though or cross-over CAT 5 cable) .There are two green lights (LEDs) located on the gateway card’s Ethernet port . If the Ethernet cable is connected to an active Ethernet port on the PC both lights should be illuminated (the light labeled Act may be flickering reflecting network activity) . 5 . The card’s default Ethernet IP address is 192 .168 .1 .1 . Set the PC’s address to an address on the same subnet, such as 192 .168 .1 .100 . To do this, use the following steps:a . Click Window’s Start . b . Choose either Settings > Control Panel (Windows 2000) or Control Panel (Windows XP) .c . In the Control Panel , click Network Connections and right-click Local Area Connection . Select Properties from the shortcut menu .d . Click the Properties button .e . In the Properties dialog box, select Internet Protocol (TCP/IP) and click the Properties button .f . In the Internet Protocol (TCP/IP) Properties dialog box, select Use the follow-ing IP address and enter the following in the IP address field: 192.168.1.100g . Click OK throughout the various dialog boxes .6 . Launch a web browser and navigate to the following IP address: 192.168.1.1If an information screen appears stating the certificate cannot be verified and asking if you want to run anyway, select run.Loading Page Java will load and then the meter’s Home page will appear .PXM 2000 Quick Start GuideConfiguring the Meter’s Gateway Card for Network Accessibility8 IM02601002EMeter Home Page 7 . Click the Setup button . The Setup page will appear . (Y ou can also click the Setup Meter link at the bottom of the page to go directly to the Quick Setup folder .)8 . Locate and click the open icon to the left of the Quick Setup folder . The folder opens to show two subfolders: Meter and Network .Opening the Quick Setup Folder 9 . Click the Network folder . 10 . Click the Edit button .Edit Button (on the right of the page)A Login dialog box appears .11 . The default Username is admin and the default Password is admin . Log in using these credentials .PXM 2000 Quick Start GuideNetwork AccessIM02601002E 9Login dialog12 . I f you successfully logged in as admin you may now configure the card for the set-tings specified by your network administrator . Refer to the previously recorded net-work settings . Y ou can also enter such optional information as the meter’s location, who to contact in case of problems, etc .13 . W hen you’ve completed configuration, click the OK button .The new IP address will take effect shortly after clicking OK . The Gateway Card will redirect you to the new IP address and reload the Java applet . Y ou can continue to configure the meter after it is connected to your LAN .Refer to the PXM 2000 Meter User’s Guide (IM02601001E) for additional configura-tion details .14 . D isconnect the Ethernet cable to the PC and connect the meter to the LAN .Note: Remember to reconfigure the PC’s network settings for your LAN .This concludes network configuration . Y ou can now proceed to verify the IP address .Verify the IP addressTo check the IP address from the meter’s front panel:1 . If the meter has power, the display should be showing normal data, such as voltage, current, etc .2 . Push the menu button on the face of the meter . The main menu screen appears .3 . Push down repeatedly until IP blinks .4 . Push enter and the meter’s IP address appears, which should appear something like the following:010.222.051.066In this example the IP address is 010.222.051.066 . This should match the ad-dress the network administrator provided for this meter .5 . Push menu to return to the main menu .Network AccessOnce the network IP address is known, most meter functions and configuration can be done via the network . Use a networked client PC running version 6 or later of the JAVA J2SE JRE and a web browser such as Internet Explorer 7 or 8 to navigate to the meter’s IP address . See the meter’s complete user’s manual for additional information .PXM 2000 Quick Start GuideRestarting and Factory Defaults10 IM02601002E Restarting and Factory DefaultsThe gateway card provides the ability to restart and to reset itself to the factory defaults . There is a momentary push-button switch accessed through a small hole in the face plate of the gateway card . Although it is not used in normal operations, this switch al-lows you to restart the gateway card in the meter .Restart the Gateway CardThe gateway card restart push-button switch is located behind the hole in the card face plate closest to the LED labelled DHCP . This switch is used to restart just the gateway card (not the meter) should it be necessary to recover from some abnormal condition .Momentarily press the switch by pushing a small device into the hole to activate the switch .Detailed information on applications and options can be found in the PXM 2000 Meter User’s Guide (IM02601001E) on the CD shipped with the meter . The guide can also be found at http://www .eaton .com/powerxpert .Eaton Corporation Electrical Group 1000 Cherrington Parkway Moon Township, PA 15108United States 877-ETN-CARE (877-386-2273)Eaton .com© 2011 Eaton Corporation All Rights Reserved Printed in USA Publication No . IM02601002E October 2011PowerChain Management is a registered trademark of Eaton Corporation . All other trademarks are property of their respective owners .。
入门指南1AgilentInfi...
AgilentInfiniiVision 2000X 系列示波器用户指南s1声明© Agilent Technologies, Inc. 2005-2012根据美国和国际版权法,未经 Agilent Technologies, Inc. 事先同意和书面允许,不得以任何形式或通过任何方式(包括电子存储和检索或翻译为其他国家或地区的语言)复制本手册中的任何内容。
手册部件号75015-97025版本第三 版, 2012 年 3 月Malaysia 印刷Agilent Technologies, Inc.1900 Garden of the Gods Road Colorado Springs, CO 80907 USA 担保本文档中包含的材料“按现状”提供,在将来版本中如有更改,恕不另行通知。
此外,在适用法律允许的最大范围内,Agilent 不对本手册及其包含的任何信息提供任何明示或暗示的保证,包括但不仅限于对适销性和用于特定用途时的适用性的暗示担保。
对于因提供、使用或运用本文档或其包含的任何信息所导致的错误或者意外或必然损害,Agilent 概不负责。
如果Agilent 和用户之间已达成的单独书面协议包含涉及本文档内容的担保条款,但担保条款与这些条款有冲突,则应以单独协议中的担保条款为准。
技术许可对于本文档中描述的硬件和/或软件,仅在得到许可的情况下才会提供,并且只能根据许可进行使用或复制。
限制性权限声明美国政府限制性权限。
授予联绑政府的软件和技术数据权限仅包括通常会提供给最终用户的那些权限。
Agilent针对软件和技术数据提供这种惯例性的商业许可时遵循 FAR 12.211(技术数据)和 12.212(计算机软件)以及国防部的 DFARS 252.227-7015(技术数据 - 商品)和 DFARS 227.7202-3(商业计算机软件或计算机软件文档权限)。
安全声明小心标记表示危险。
A2000多功能电量表操作手册
500 V
源点
限值
继电器 1
11
5A
继电器 2
U1
240V
源点
输出
模拟输出 1
PΣ
4 … 20mA
模拟输出 2
QΣ
4 … 20mA
模拟输出 3
12
4 … 20mA
模拟输出 4
U2
4 … 20mA
源点
能量类型
S01
E PΣ
有功能量
S02
E PΣ
有功能量
显示
亮度, 5
R S 2 3 2, RS
485
波特率 9600
4
2.2 输入 、输出和接口 电流输入
所有电流输 入互相隔离。 如果用外部互 感器进行测量 ,为了能够直 接显示电流值 ,它们的 初级和次级电流值必须输入。两个测量范围(1A和 5A) 之 间 的转换通过软件完成。
在 3或 4线系统 中与3个 电流互感器连 接
在 3 线 系 统中与2个 电 流互感器连接
变比可输入仪表,也就是说所有基本测量数据可在A2000上 直 接 显 示。每个测量值或计算 量的最大值 保存在存储器 中,如果超过 限值,通过继 电器输出可触 发正确的动作 。能量仪 表,记录仪,数据记录器和控制环 路连接至数据和模拟输出,该仪表可用通讯接口集成进 现场总线系统或LON网络中,它的参数可用一台PC设 定 。
来源
1) 4) 5)
输出
0 — 20m A 4 — 20m A
- 2 0 — 20mA
脉冲输出 SO 1 ,SO2
来源
能量类型
U1,U2,U3,U∑ 有功 ,无功能量
显示 接口
RS232,RS4
亮度 0—7 地址
GDS-2000系列数字存储示波器 说明书
数字存储示波器GDS-2000 系列使用手册固纬料号: 82DSB22040MA1ISO-9001 CERTIFIED MANUFACTURER本手册所含资料受到版权保护,未经固纬电子实业股份有限公司预先授权,不得将手册内任何章节影印,复制或翻译成其它语言。
本手册所含资料在印制之前已经过校正,但因固纬电子实业股份有限公司不断改善产品,所以保留未来修改产品规格,特性以及保养维修程序的权利,不必事前通知。
固纬电子实业股份有限公司 台北县土城市中兴路7-1号目录目录安全说明 (5)产品介绍 (9)GDS-2000 系列简介 (10)产品外观 (13)设定 (21)快速操作 (25)树状菜单/快捷操作方式 (26)默认设定 (44)内置帮助功能 (46)测量 (47)基础测量 (49)自动测量 (56)游标测量 (61)数学运算操作 (65)Go-NoGo 测试 (70)编程 (79)设置 (84)采样 (86)显示器 (92)水平检视 (96)垂直检视 (通道) (103)触发 (107)系统信息/语言 / 时间 (117)存储/调取 (120)GDS-2000系列使用手册文档格式 /Utility (121)快速存储 (硬拷贝) (128)存储 (130)调取 (139)打印 (148)远程控制 (151)接口设置 (152)电池操作 (158)保养与维护 (160)垂直分辨率校正 (160)探棒补偿 (161)常见问题解决方案 (163)附录 (166)更换保险丝 (166)GPIB 模块安装 (167)GDS-2000 规格 (168)探棒规格 (171)Declaration of Conformity (172)索引 (173)安全说明本章包含操作以及储存示波器时所必须遵照的重要安全指示。
操作前请先详细阅读以下指示,以确保安全并使仪器保持在最佳状态。
安全符号以下安全符号可能会出现在本手册或仪器上。
2000系列设备初学者指南说明书
Table of Contents1Introduction (2)2Configuring your Unit via the Serial Port (3)Step 1 - Identify the Components (3)Step 2 - Connect the Leads (3)Step 3 - Power up & check the Unit (4)Step 4A - Install Drivers (Windows 95 / 98) (4)Step 4B - Install Drivers (Windows 2000) (5)Step 5A - Configure Dial Up Networking (Windows 95 / 98) (9)Step 5B - Configure Dial Up Networking (Windows 2000) (13)Step 6 - Connect to the Web Server (16)3Hints (17)4Support (17)Sarian and Routerplexer are trademarks of Sarian Systems Lt d. Microsoft, Windows 95, Windows 98 & Windows 2000 are registered trademarks of Microsoft Corporation. All other trademarks are acknowledged.Changes are periodically made to the information herein; these changes will be incorporated into later editions of this publication.Comments on the content or style of this document are gratefully received, please e-mail*****************.ukPleasenotethatthise-mailaddresscannotbeusedforsupportquerieswhich should be made via the contact details on the support section of our website at © 2002 Sarian Systems Ltd. All rights reserved, including those to reproduce any or all parts of this publication in any form without permission in writing from Sarian Systems Ltd.1 IntroductionThank you for purchasing a Sarian Systems 2000 Series Communications device.This “Getting Started” guide will help you to make initial contact with your unit in order to set the configurable options. The vast majority of applications, however, will need very little configuration to operate correctly.Your unit has a wide range of advanced features ranging from remote management, protocol conversion and diagnostics to in-built protocol analyzers.To understand how to use these features, you should carefully read the attached documentation which is supplied either on CD-ROM or paper. The CD-ROM contains a full User Guide in Adobe™ Acrobat™ format and we recommend that you read this thoroughly in order to get the best out of your unit.IMPORTANT : Throughout this guide we will use the IR2140 Router as an example, however the instructions apply equally to any Terminal Adaptor, Multiplexer or other specialist device in the Sarian 2000 series.There are four ways you can send configuration commands to your unit :• Using a Web Browser to access pages on the built in Web Server• Command line sessions via Telnet• Sending a specific configuration file using FTP• By sending ‘AT’ type commands to the serial portUsing a web browser such as Netscape Navigator™ or Internet Explorer™ is simplest and easiest to understand method and is the one explained in this booklet. The other methods are described in full in the User Guide on the CD-ROM.To configure your unit via the built in web server, you will first need to establish a PPP serial connection between your unit and a local computer via the supplied serial cable, then use a web browser to access the configuration pages where you can make the necessary configuration changes.Note that steps 4 and 5 are different depending on your operating system.2 Configuring your unitStep 1 - Identify the ComponentsIn the packaging you should find the following items :• One System Unit• Serial Modem cable for configuration• One ISDN patch lead (ISDN capable units only)• One Plug Top Power supply• Serial adapter leads (RJ45 to 9 or 25 Way D Type) (optional)• One CD-ROM containing full documentation• This “Getting Started Guide”Step 2 - Connect the LeadsUsing the supplied serial cable connect a PC or laptop to the 25 way socket marked ‘PORT 0’. Next, connect one end of the ISDN patch lead into the Router socket marked ISDN BRI and the other end into the ISDN network socket installed by your network provider. Be careful not to accidentally plug the ISDN circuit into a serial port !Finally, plug the connector of the power supply into the socket marked 12V DC and plug the adapter into a convenient mains power outlet.The above picture is the rear panel of an IR2140 Router. Other types of unit, such as theIR2110 and GR2130 routers may have slightly different back panel layouts, however, ISDN BRI, 12V DC and PORT 0 will still be clearly marked as above.The serial ports equipped with an RJ45 socket (PORT 2 & 3 in the photo above) require adaptor leads to connect them to your serial devices. These may optionally be supplied with your unit or you can make them up yourself according to the wiring diagram shown in the full User Guide on the CD-ROM.Step 3 - Power up & check the UnitWhen power is applied, the red ‘ON’ indicator will light on the front panel and the unit will self-test.All green lights on the front panel will flash rapidly and then go out. The ‘B2’ light will then flash alternately red and green to indicate self test in progress, then ex tinguish.If you have connected the unit to an ISDN line in Step 2, it will then try to establish a connection to the local exchange via the D Channel. If it succeeds, the ‘D’ indicator will come on and remain lit.If any other lights except the ‘ON’ and ‘D’ indicators remain on, the unit has a detected a fault and you should consult the full documentation for further guidance. DO NOT TRY TO ACCESS THE UNIT UNTIL THE SELF TEST IS COMPLETE.Now proceed to Step 4A for Windows 95/98 or Step 4B for Windows 2000.Step 4A - Install Drivers (Windows 95 / 98)Switch on your PC and from the Start Menu select START > SETTINGS > CONTROL PANEL> MODEMS and click on the Add button.Windows will advise that it will try to detect your modem. Since we are making a manual installation, ensure that the ‘Don’t detect my modem, I will select it from a list’ is checked and click Next >.You will be presented with a list of devices. Ignore these and click on Have Disk…You will now need to place the supplied CD-ROM in the drive. Browse to it until you locate the .inf file for your unit as below which is located in the /drivers/win95-98/ folder, then click on OK and then OK again. You will then be presented with a list of available drivers and you should select the appropriate Sarian 2000 Series variant to match your unit.You will then be asked to confirm which communications port you have connected the serial lead to as below :You should click Next > and the driver should install. You will then see a confirmation that the configuration is complete and you can click Finish.Now proceed to Step 5A – Configure Dial up Networking (Windows 95/ 98).Step 4B - Install Drivers (Windows 2000)From the Windows Start menu, select Settings > Control Panel then click on the Phone And Modem Options icon. Click on Modem Tab. The following dialogue will appear :Click Add.. then check “Don't detect my modem; I will select it from a list” as shown below, then click Next>You will see the following dialogue asking you to select the appropriate device. Click Have Disk…You will now need to insert the CD-ROM which came with your unit and browse to the folder /drivers/win2000 then select Sarian .inf file there. The following dialogue will appear :Select the appropriate modem (e.g. Sarian Systems IR2140 ISDN Router), then click Next>. Either select the individual communications port you wish to connect your Sarian unit to or select All PortsClick Next>.Answer Yes to the “digital signature not found” dialog box and then click Finish.Now proceed to Step 5B – Configure Dial up Networking (Windows 2000).Step 5A - Configure Dial Up Networking (Windows 95 / 98)From the windows desktop, double click on the ‘My Computer’ icon.. Click on ‘Dial-Up Networking then ‘M ake New Connection’.Type in ‘M y Sarian’or some other meaningful phrase and select‘Sarian Systems Series 2000’ so that the screen looks like the one below :Next, click on CONFIGURE… and ensure that the correct COM port (i.e. the one c onnected to PORT 0 of your unit) for your PC is selected on the General tab and that the maximum speed is selected as 115200. You screen will look as below :Now selec t the Connections tab and set the data format to 8 data bits, NO Parity and 1 stop bits like this :Click on OK to return to the Make New Connection dialogue and press Next>. Now type in 123 as the Telephone number and ensure the Area Code is blank, like this :When you have done this, click Next>.The next dialogue screen will confirm the completed connection. Press Finish to complete the configuration.Before attempting to connect, check the Dial-Up networking properties by right clicking the newly created connection and selecting Properties. On the General tab, make sure that‘Use area code and Dialing Properties’ is not checked.Now select the ‘Server Types’ tab and ensure that that all the boxes are unticked EXCEPT for TCP/IP as below :Finally, click OK to close the dialogue box. You have now configured the Dial Up Networking and now will use the connection you just made to dial up the unit through the serial cable. Click on the Dial Up Networking Connection you have just created and enter the User Name as ‘username’ and the Password as ‘password’ as shown belowClick the Connect button. You will see a series of status dialogues from Dialing … through Verifying User Name and Password … to Logging on to Network … then you should see the modem lights in the system tray (next to the clock):You now have a connection between your PC and the Sarian unit, you now need to connect to the web based user interface to configure the unit.Now proceed to Step 6– Connect to the Web Server.Step 5B - Configure Dial Up Networking (Windows 2000)From the Windows menu, select Settings then click on the Network and Dial-up Connections icon, then on Make New Connection. Click Next> to start the Network Connection Wizard.Select "Dial-up to private network" and click Next>. Then select ‘Modem - Sarian Systems (your com port)’ and click Next>. You will see the following dialogue :E nter 123 as the phone number and ensure that "Use dialing rules" is NOT checked. Click Next>.Decide whether to create this connection for all users of your PC or just yourself and click Next>.Give the connection a suitable name (e.g. “Sarian IR2140”) and then click Finish to create the new connection.Next, click on properties, and select the networking tab. You should have a dialogue like this:Ensure that the only component checked in the list is Internet Protocol (TCP/IP). Click the settings button and ensure that all of the PPP settings are un-checked. Now click the General tab. Select the “Sarian Multiplexer” and click Configure.Ensure the “Maximum speed (bps)” is set to 115200, ensure that the only check box on this page ticked is that for the “Enable Hardware flow control”. Click OK and click OK again. You will now be asked to dial the connection you just made. Enter "username" in the user name field. Enter "password" in the password field (case sensitive !). Check the “Save Password” box and click Dial.Your PC should now connect to the Sarian router and you should see the modem lights icon appear in the system tray, like this :Now proceed to Step 6 – Connect to the Web Server.Step 6 - Connect to the Web ServerStart a web browser on your PC (Netscape Navigator or Internet Explorer 5.0 or greater). Point your web browser at http://1.2.3.4. You will see a login prompt from the unit’s built in web server.Type in the default username which is ‘username’ and the default password which is‘password’, then click on Login.If everything is connected up properly, you will see the following configuration page :You can now go on to set the individual settings for your Sarian unit using the web based interface. Most of the settings are straightforward, but if you are in any doubt, check the full documentation which came with your unit or contact Sarian Systems at the address below.3 HintsThe above instructions assume that you already have Dial-Up Networking and TCP/IP installed on your computer. If you do not you should consult your Windows documentation on how to do this.If your unit has a LAN port, you can bypass the instructions in Section 2 about installing drivers and connect directly to the web server on the default IP address 192.168.0.99. Make sure that your PC is on the same sub-net.If you do not yet have a network installed, you can use a 10BaseT CROSSOVER cable to effect a one to one connection between your PC and the unit. Note that 2000 series units with a hub can use either a crossover cable or a standard LAN patch lead and the unit will autodetect the type.Remote connection. If you wish to connect to a remote Sarian 2000 unit, follow the installation guidelines given above, but substitute your own local ISDN Terminal Adaptor details. When asked for the number to dial, instead of ‘123’ type the full ISDN telephone number including the area code.4 SupportTips and guidance on the installation and use of your unit can be found on the Sarian Systems website at under the support section. New versions of the firmware for you unit may also be available for download from the website.If, despite reading the user documentation you still cannot get your unit to operate either :Call Sarian Systems Support Helpline on 01943 605055orSubmit an e-support request via orContact Sarian Systems atSarian Systems Ltd.Beacon HouseRiverside Business ParkLeeds RoadIlkleyW. YorksLS29 8JZFax : 01943 605056。
ICP DAS USB-2000系列 USB I O 模块使用指南说明书
USB I/OQuick Start1Module OverviewFigure 1-1 USB-2000 Module OverviewFigure 1-2 USB-20XX-XX Module OverviewThe package includes the following items:●One ICP DAS USB I/O module●One Quick Start●One USB cable with lockable kitIt is highly recommended to read the Quick Start first before using ICP DAS USB I/O modules. There is some useful information in the Quick Start:●How to install hardware and use utility3LED Indicators3.1Normal Mode3.2Firmware Update ModeFigure 4-1 Connection diagram4.1Connect to ICP DAS USB I/O series module1.Turning on the PC you are preparing to configure ICP DAS USB I/O modules.2.Connecting the ICP DAS USB series I/O modules to USB 2.0 port or higher on the PC by using cablein the box.3.Once you first time connect the USB I/O module to PC. There will be few messages in system bar inbottom right side to inform new hardware is detected and installed successfully. After the message is shown as figure 3-2, then the ICP DAS USB series I/O modules are ready to use.Figure 4-2 The system detects the ICPDAS USB series I/O modules has plugged inFigure 4-3 The ICPDAS USB series I/O modules are ready to use5Software InstallationThe software installer includes libraries, samples and Utility, and can be found in web site. You can install the package by double clicking the file “ICPDAS USB IO X.X.X.exe”. Then follow the instruction during installation.Figure 5-1 The welcome message of the ICP DAS USB series I/O installerAfter the installation, the window will indicate the installation has completed as the figure below. Users can check the patch note to see the change or ignore.Figure 5-2 The installation has complete5.1.1UtilityThe USB I/O Utility provides a simple way to test and acquire data easily and instantly for all ICP DAS USB series I/O modules without programming. You will find this program in“Start\Programs\ICPDAS\USB IO\USB IO Utility” or the path “C:\ICPDAS\USB IO\USB IO Utility\USB IO Utility.exe”. The detail of how to use USB-2K Utility can be referred to user’s manual in section 3.2.1.5.1.2ICP DAS USB I/O SDKThe USB I/O libraries are the way to access ICP DAS USB series I/O modules. It supports various IDE like C#//VB/VC/BCB. Users can choose any IDE you familiar with. Before starting up project, you need to do some configuration to integrate the SDK into your IDE. For more details, please refer to Section 3.2.2 in user manual.5.1.3SamplesThere are several samples to help user to develop project smoothly. The samples can be found in “Start\Programs\ICPDAS\USB IO\Samples” or the path “C:\ICPDAS\USB IO\Samples“6Software Development DiagramClassInitialization OpenDeviceAccess I/ODI_...DO_...AI_...AO_...PI_...PO_...CloseDevice1.Cannot install ICP DAS USB I/O package with the message like the following figure.Because the ICP DAS USB I/O requires .NET Framework v2.0, the package will automatically detect the .NET Framework v2.0 installed as well or not. Users can click “Yes” to download and install the .NET Framework v2.0 via internet. If users can not access internet, the other way is install .NET Framework v2.0 in the folder “net_framework “ in the root path of the CD.2.Returning timeout error code (65792) after calling set methods or read value.There are some possible reasons as follow:●USB modules connected to USB hub not local USB port on computer, and communicationtimeout is too low to communicate.(Note: We strong recommended connecting USB modules to local USB port on computer to prevent unexpected problem.)●Module is failure caused by unknown reason. You can refer to LED indicators section.●The main page of the USB I/O/root/product/solutions/remote_io/usb_io/usb_io_introduction.html ●The product selection guide of the USB I/O/root/product/solutions/remote_io/usb_io/usb_io_selection.html。
EASTMAN KODAK COMPANY KCPS快速引导说明书
Quick Start GuideNOTE: The Kodak Creative Production Software (KCPS) configures itself based on your country and license level. Not all sections are applicable.Installation1. Insert the CD into your CD-ROM drive. WINDOWS detects the KODAK CreativeProduction Software (KCPS) automatically and starts the installation process.2. Follow the on-screen instructions to complete the install.Setup1. Select a type of installation. Typical is recommended. Quick is recommended fortrying the software before using it in a production environment.2. Choose a workstation setup. If you are not sure what option to select:• A stand-alone install runs the software on a single computer using only local paths. No other computers are connected to it, nor does thecomputer share files with a computer running the KCPS software.• A server-install runs the software on a central computer over a network and has multiple computers running the KCPS software. The centralcomputer is set up to share files that the computers will be able toaccess.Client/Server Setup: WINDOWS FirewallWhen setting up KCPS as a workstation/server configuration, your KCPS workstation may not communicate with your server due to the WINDOWS firewall. To allow the workstation to communicate with the server through the WINDOWS firewall:1. On the server machine go to Settings > Control Panel > WINDOWS Firewall.2. Click the Exceptions Tab and then click Add Program.3. From the Add Program window click Browse. Navigate to the following location:C:\ProgramFiles\MicrosoftSQLServer\MSSQL$KEXDSSSERVERF\Binn\sqlservr.exe and click OK.Client/Server Setup: Sharing FoldersWhen setting up KCPS as a workstation/server configuration, the KCPS folder needs to be shared so other KCPS workstations can access files. To share the KCPS installation folder:1.On the server computer, browse to the KCPS folder (where you have your softwareinstalled)and right-click the folder.2.From the KCPS Properties window click the Sharing Tab.3.The Allow network users to change my files check box is selected by default, click todeselect the option and click again to re-select it.4.Click Apply.Network Printer Configuration• For most printers you will need to know your printers network IP address and resolution so that you can configure the KCPS software properly. When you havethis information write it down until you are ready to enter it into the necessary fields.If you do not know where to find this information ask your KODAK ServiceRepresentative.• Many printers communicate with a Hotfolder Application. You should know which type of Hotfolder applications can interface to your printer. Make sure the application is installed in the correct location and installed on the workstation that is sendingfiles to the printer running the KCPS software.• When you setup your printer you will need to save your image files to a shared folder. The printer needs to be able to access the shared folder so be sure the pathis a Universal Naming Convention (UNC) path. For example:(\\servername\sharedfoldername).APEX PrintersIf you are sending work to an APEX printer, your product sizes must be supported by APEX. The following sizes are supported:• 4x6• 5x7• 6x8• 8x10• 8x12WINDOWS Printers ConfigurationYou will need to create a WINDOWS printer configuration file when setting up a new WINDOWS printer. To do this:1. Select WINDOWS printer from the list of printers.2. Enter a name for your printer.3. Enter a name for your new configuration file then click Page Setup.4. From the Page Setup window click the Printers button.5. Make sure Portrait is selected for all WINDOWS printers.6. Choose the correct printer from the list and click OK.7. Enter a name for your printer queue.8. Click the button and select an output profile for your printer.9. Click Save to finish.Noritsu QSS31 Pro Printer ConfigurationThe Noritsu QSS 31 Pro printers communicate through a HotFolder application. TheQss31Pro Image Print Server (IPS) is a hot folder application that allows the KCPSsoftware to print to the Qss31Pro printer. This application needs to be setup on thecomputer, which is sending files to your printer.1. To open the IPS application, browse to Program Files\Kodak\KCPS\QSS31Profolder and click the KODAKPROFESSIONALQss31ProImagePrintServer3.0.8.exeto run it. Follow the on-screen instructions to install the application.2. Open the IPS application, from the Edit Menu select Application Parameters.3. Enter your printer IP address and click OK.FTP SetupFile Transfer Protocol (FTP) is an optional feature used to upload jobs to a central printing location. An FTP Username and Password are required. If you do not have this information contact your KODAK Service Representative.Print/Collage Sizes and PricesYou will have to define your print sizes and prices. The software sets the following default print sizes:• 4x6• 5x7• 8x10• 11x14You can modify these sizes as necessary. You must assign a printer queue to each print.Poster/Photo ID Sizes and Prices and Image Mastering PricesIf you are offering Posters/Photo IDs, you need to define the sizes and prices for each. You must assign a printer queue to each print. Assign prices for CD/DVD products.Book Sizes and PricesIf you are offering photo books you need to define the sizes and prices. You must assign a printer queue to each print.Click the button to open the next window for defining your book layout.Enter the margins for the pages and the cover page..License ManagementThe software communicates with a license server and requires Internet access. If you do NOT have Internet access, you can upload your license_request.xml file manually. Find the file by browsing to the KCPS folder where you installed the software.1.Find a workstation that is connected to the Internet and open a web browser.2.To upload the file go to: /kex/UploadLicenseRequest.3.The link is also available in the software by opening Help. From the Licensey openingthen click the link to upload the file.Management screen,click the Advice iconBluetooth™ TechnologyNote: To import images into the software your Bluetooth USB device must be Bluetooth Certified. Microsoft Windows XP Professional Only.Install the USB device then follow the screens from the Found New Hardware Wizard.1. Select the option to Install the software automatically (Recommended).2. Select the Bluetooth HCI USB Driver.3. After the installation is complete restart the software.Getting StartedAfter you set up the software the welcome screen for KODAK Creative Production Software will open.The NavigatorTo access the Navigator window follow the steps below. You can use the Navigator to manage different areas of the software.1.Click the Administration button to open the Navigator.2.The password for the Navigator is blank. Click OK.3.To set your own password, click Change Password.Keep a record of yourpassword in a safe place.To get back to the Welcome Screen, click the KCPS Welcome button at the bottom of the Navigator.Getting HelpHelp is available inside the software. Here are a few ways you can get assistance from any screen:1.Click Helpto open the manual. The manual can also be opened from the Navigator.2.Click Advice to o to open help for the current screen.Render EngineThe render engine sends your work to a specific printer and is automatically started when you start the software. 1.From the Navigator window, select Printing >Render Engine .2.From the Render Engine Controls screen, select a printer and then click Shutdown .Note:After clicking the shutdown button, wait for the checkbox to clear before choosing another render engine.Installation (China)1.Insert the CD into your CD-ROM drive. WINDOWS will detect the KODAK Creative Production Software (KCPS) automatically and start the installation process.2.Follow the on-screen instructions to complete the install.3.The Routing Exporter screen will automatically open.Enter your password. To get apassword contact your KODAK Service Representative.。
四川快速2000系统调试手册
本表是表示不遵守说明书上要求的程序的场合会发生电击危险 的部分。
第1页
四川快速电梯有限公司 Sichuan Express Elevator Co., Ltd.
SEEC
电梯串行控制系统调试手册
序言
INTL’2000 电梯控制系统是我公司推出的智能化更高、功能更强、调试与维护更方 便的高技术产品。它除了具有一般电梯控制系统的基本功能外,在系统参数设置、电梯 功能选择、电梯调试与维护、现场适应能力等各方面有独到之处。
本系统的基本控制方式为串行通讯(CAN 总线)与变频调速;可满足电梯楼层 64 层以下,电梯速度小于 4 米/秒,包括永磁同步电机在内的各种电梯电机的控制要求。
INTL’2000 型电梯电脑控制器的主板、操纵盘板、呼梯板的核心芯片是国际著名工 业用单片机制造商 FUJITSU 的内部具有 32 位处理器的高端产品,集成度、可靠性堪称 世界一流;软件设计充分体现了功能齐备,参数设置界面层次分明,调试及故障诊断信 息充分,抗干扰能力强及干扰强度评价独具匠心的技术特点。对电梯控制系统以外的电 气元件设计了诊断与检测界面。使电梯故障判断有的放矢,真正使该电梯控制系统做到 了高性能与可靠性的完美统一,高水平与实用性的完美统一,高科技与应用简便的完美 统一。
1.2.3 防捣乱
当电梯运行至最远端楼层换速时,清除所有的内选登记。若电梯有负载检测装置,当轻载时, 内选最多可登记3个,多选无效。
1.2.4 呼梯按钮嵌入自诊断
若某一呼梯按钮按下时间超过 20s 而未断开,则系统认为该按钮嵌入。以后对该层呼梯不予登 记,且该按钮对应的呼梯应答不断闪烁报警。当该按钮断开时,退出上述状态。
SEEC
第一章
电梯串行控制系统调试手册
ICP DAS ZT-2000 DIO 系列快速入门指南说明书
ZT‐2000 DIO SERIESQuick Start 1What’s in the Shipping Package?The shipping package contains the following items:2Preparing the Device1.Refer the chapter 3. to configure the DIP switch of ZT-2000 I/O device.2.Install the ZT Configuration Utility to configure the ZT-2000 coordinator.CD: \Napdos\ZigBee\ZT_Series\Utility/pub/cd/usbcd/napdos/zigbee/zt_series/utility3.Power Supply: +10 ~ +30 V DCANT‐124‐05 Quick StartZT‐2000 DIO Device+Vs GNDIf any of these items are missing or damaged, please contact your local distributorfor more information. Save the shipping materials and cartons in case you need toship the module in the future.3 Setting up the ZT ‐2000 DIO Device3.1 Introduction to the Configuration ParametersA. “Pan ID” parameter is the group identity for a ZigBee network, and mustthe same for all devices in the same ZigBee network.“Node ID” parameter is the individed identity of a specific the ZigBee module, and must be unique for each device connected the same ZigBee network.B. “RF Channel” parameter indicates the radio frequency channel, and mustbe set to the same value as other modules on the same ZigBee network.Channel0x000x01 …… 0x0F Frequency(MHz) 24052410……2480※ RF channels 0x04, 0x09, 0x0E or 0x0F are recommended because they do not overlap with the Wi-Fi frequencies based.C. Protocol/Application Mode:When implementing custom programs based on different protocols, the following application modes are recommended in order to ensure communicatibleUser Program Protocol ZT-2000 I/OZT-2550 ZT-2570 DCON DCON Transparent Transparent Modbus RTU Modbus RTU TransparentModbus Gateway Transparent Modbus GatewayModbus TCPModbus RTU------Modbus Gateway802.11b/g Channel 802.11b/g Channel 802.11b/g Channel4 Rotation Switch and DIP SwitchThe configuration of ZT-2000 series can be adjusted by using the external rotary switch and the DIP switches. The ZT-2000 device should only be rebooted once the configuration is complete.DIP Switch to the ZT‐2042/ZT‐2043/ZT‐2053DIP Switch to the ZT‐2052/ZT‐2060123456789101112 Address LSB(Node ID)Address MSB(Node ID)ProtocolChecksumPan IDONRF Channel Reserved (Node ID) (Node ID)ProtocolChecksumPan IDRF ChannelRotation Switch0 1 2 3…… FNoteAddress SW 01 02 03 …… 0F Node ID SW 0x0001 0x0002 0x003…… 0x000F MSB = 00 1 2 3…… FAddress 10 11 12 13…… 1F Node ID 0x0010 0x0011 0x0012 0x013 ……0x001FMSB = 1※ Once the address of hardware switch is set to 0x00, it mens the address is using software configurations. Refer the more detailed information at Sec. 6.6 of user manual.DIP SwitchNumberItemStatus Explain OFF Valid address(Node ID) from 0x00 to 0x0F1 Address MSBON Valid address(Node ID) from 0x10 to 0x1F OFF DCON Protocol2 ProtocolON Modbus RTUProtocol OFF Disabled3 ChecksumON Enabled OFF Pan ID = 0x00004 ZigBee Pan IDON Pan ID = 0x0001 OFF ------5ON 0x08 OFF ------6ON 0x04 OFF ------7ON 0x02 OFF ------8ZigBeeRF Channel ON 0x015 Start‐up ZT‐2000 I/O DeviceAs the ZigBee network is controlled by the ZigBee coordinator, the ZT-2550/ZT-2570 (ZigBee coordinator) must be configured first. Please refert to documents shown below for full details of how to configure these devices.Once configuration of the ZigBee coordinator has been completed. Set the ”Pan ID” and the “RF Channel” values for the ZT-2000 I/O device to the same values as the network, and then reboot the device. The module will automatically start to function on the ZigBee network using the default protocol.※ Documents/pub/cd/usbcd/napdos/zigbee/zt_series/document/zt-255x/ /pub/cd/usbcd/napdos/zigbee/zt_series/document/zt-257x/※ Configuration Utility(Used to configure ZT-2000 I/O device Coordinator) /pub/cd/usbcd/napdos/zigbee/zt_series/utility/6 ExamplesConfigurations of ZT‐2550/ZT‐2570Configurations of ZT-2000 I/O Device12345678910111212345678 ONNumber Item Status Explain1 Address MSB OFF Address/Node ID is 01(Rotation Switch=1)2 Protocol ON Use Modbus RTU Protocol3 Checksum OFF Disabled4 ZigBee Pan ID OFF Pan ID=0x00005 ON 0x086 ON 0x047 ON 0x028ZigBeeRF ChannelOFF ------ZigBee RF Channel = 0x0E7 Communication TestOnce the ZT-2000 I/O device has joined the ZigBee network, the signal quality can be comfirmed by monitoring the status of the ZigBee Net LED indicators. If the LED indicator shows a steady light, communication with the ZT-2000 I/O device has been successfully established for data acquisition and control.ICP DAS also provides the “DCON Utility”, which can be used to simulate DCON/Modbus communication. This software can also be used to verify the device settings and ZigBee I/O functions.※ The DCON Utility can be dowmload from:/pub/cd/8000cd/napdos/driver/dcon_utility/Simulate I/O channel operating via using DCON Utilityunch DCON Utility and select the correct COM Port settings to connect theZigBee Coordinator (ZT-2550/ZT-2570).2.Clicking “Search” button will start searching which ZT-2000 I/O device is in thesame ZigBee network.3.If there is any ZT-2000 I/O devices displayed, double clicking the “modulename” will start the I/O channels operated platform.8 Troubleshooting(1)Technical Support.If you have any difficulties using your ZT-2000 series I/O device, pleasesend a description of the problem to ******************Include the following items in your email:● A description or diagram of the current DIP switch positions.● A copy of the configuration file for the ZT-2000 coordinator. This file can beobtained using the procedure outlined below and should be attached to youremail.a.Set the DIP switch of the ZT-255x device to the [ZBSET] position thenreboot the device. Launch the ZT Configuration Utility and select [Save Log] icon to save the configuration of the ZT-255x as a file.b.After clicking the [Save Log] icon, enter the “File Name” and the “File Path”in the Windows “Save” dialog box. Once the configuration has beensuccessfully saved, the following message will be displayed.(2)LED Indicator Status:LED Indicator Status IntroductionZigBee Router (Slave)Steady Lit The Signal is StrongBlinking (500 ms) The Signal is AvailableBlinking (1s) The Signal is WeakBlinking (2s) The Signal is Unstable or There is no AvailableThe status of module boardSteady Lit The Power is ON and the Module Initialization is CorrectBlinking (200ms) Module Initialization FailureBlinking (1s) Watchdog is Enabled and the status of the I/O channel has been changed to the Safe Value. Reset the module via the power switch or configuration commands.ZigBee PWR(Red LED)Steady Unlit The Power is OFFThe status of DI/DO channelsSteady Lit The DI/DO channel is Enabled ZigBee DI/DOSteady Unlit The DI/DO channel is Disabled。
快速指南
产品认证
RIGOL 认证本产品符合中国国家产品标准和行业产品标准及 ISO9001:2008 标准和 ISO14001:2004 标准, 并进一步认证本产品符 合其它国际标准组织成员的相关标准。
联系我们
如您在使用此产品的过程中有任何问题或需求,可与 RIGOL 联系: 服务与支持热线:800 810 0002 或 400 620 0002 网址:
注:附件示意图仅供参考,请以实物为准。 DG1000 快速指南 3
RIGOL
调整手柄
参照下图调整 DG1000 的手柄,确保仪器平稳放置于工作台上,且处 于最佳观察位置。 调整方法:握住仪器两侧的手柄,沿箭头方向用力,同时旋转手柄至 所需位置。
图 2 调整手柄的方法
图 3 平放位置和移动位置
4
DG1000 快速指南
6
DG1000 快速指南
RIGOL
用户界面
DG1000 提供 3 种界面显示模式,并可以通过前面板的 键切换。
单通道常规显示模式
输出配置 状态区 波形图标区 操作菜单区 当前活动通道 参 数 显 示 区
单通道图形显示模式
当前活动通道 状态区 参数显示区 显示菜单按键 参数显示区 波 形 显 示 区
DG1000 快速指南
V
RIGOL
初步检查
一般性检查
1. 检查是否存在因运输造成的损坏。 请保留被损坏的货运包装或防震材料, 直到货物经过完全检查且 仪器通过电气和机械测试。 因运输造成的仪器损坏,由发货方和承运方联系赔偿事宜。 RIGOL 公司恕不进行免费维修或更换。 2. 检查整机。 参考下面的前、后面板示意图进行整机检查,若有机械损坏或缺 失,或者仪器未通过电气和机械测试,请联系 RIGOL 经销商。 3. 检查附件。 关于随机提供的附件明细,请参照下面的“标准附件示意图” 。 若包装中内容有缺失或损坏,请联系 RIGOL 经销商。
ICP DAS CAN-Logger 系列快速入门指南说明书
Quick Start for CAN ‐Logger seriesDec 2015, Version 1.0.2Congratulations on purchasing CAN ‐Logger series ‐ the most popular automation solution for CAN Bus data logging. This Quick Start will provide information needed to get started with CAN ‐Logger series. Please also consult the User Manual for detailed information on the setup and use of CAN ‐Logger series.C A N ‐L o g g e r s e r i e s Q u i c k S t a r tIn addition to this guide, the package includes the following items:CAN ‐Logger100 or CAN ‐Logger200Software Utility CDUSB cable (CA ‐USB15)Screw Driver (1C016)microSD ( 3LMSD ‐4000‐1)M12A ‐5P ‐IP68 connector(4PIO1K0000003) Core(4SIO1K0000014)y CAN ‐Logger series User ManualCD:\fieldbus_cd\can\can ‐logger\manual\ftp:///pub/cd/fieldbus_cd/can/can ‐logger/manual/y CAN ‐Logger series Website/root/product/solutions/industrial_communication/fieldbus/can_bu s/specific_device/can ‐logger.html y ICP DAS Website1 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Hardware InstallationBefore using CAN ‐Logger device, some things must be done.Step 1: Prepare one CAN ‐Logger deviceStep 2: Set the CAN baud rate of CAN ‐Logger device by using rotaryswitchC A N ‐L o g g e r s e r i e s Q u i c k S t a r t0 Set baud rate to 10 kbps 1 Set baud rate to 20 kbps 2 Set baud rate to 50 kbps 3 Set baud rate to 100 kbps 4 Set baud rate to 125 kbps 5 Set baud rate to 250 kbps 6 Set baud rate to 500 kbps 7 Set baud rate to 800 kbps 8 Set baud rate to 1 Mbps9 Set baud rate to user ‐defined baud rate which is configured by CAN ‐Logger utility. A~E N/AF Set CAN ‐Logger device into firmware update mode. The firmware update tool is needed.Step 3: Determine if theterminator resistor is needed or notCheck the applicationstructure, and determine if the terminator resistor is needed or not. You can find it at theposition as follows.C A N ‐L o g g e r s e r i e s Q u i c k S t a r tGenerally, if your application is as follows, we recommend you to enable the terminator resistor.If your application is like the structure as follows, the terminator resistor is not needed.Step 4: Connect the CAN port, power line, frame ground or USB port ofthe CAN‐Logger device.The pin assignment and wire connection are as follows. When finished, run your application with the CAN‐Logger device.CAN‐LoggerseriesQuickStartMeaning1 F.G. Frame Ground.2 +Vs Voltage Source Input. +10VDC ~ +30VDC.3 GND Power Ground.4 CAN_H CAN_High, signal line of CAN port.5 CAN_L CAN_Low, signal line of CAN port.2 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Utility toolWhen users want to use user ‐defined CAN baud rate, CAN message filter and diagnostic function on the CAN ‐Logger series, the CAN ‐Logger Utility tool may be needed.Step 1: Install the CAN ‐Logger UtilityThe software is located at:Fieldbus_CD:\CAN\Converter\CAN ‐Logger\Software\Utility/products/Remote_IO/can_bus/can ‐logger.htmC A N ‐L o g g e r s e r i e s Q u i c k S t a r tStep 2: Setting up the CAN ‐Logger module1. Connect the PC available USB port with the USB port of the CAN ‐Logger device. Users canfind the communication cable (CA ‐USB15) in the product box.2. Execute the CAN ‐Logger Utility tool.Step 3: Configure the CAN ‐Logger seriesWhen executing the Utility, the tool will try to scan all the necessary CAN ‐Logger modules and list all scanned module information on the left ‐bottom of the Utility main frame. User can press the “Refresh” buttom to re ‐scan the newer inserted CAN ‐Logger module.C A N ‐L o g g e r s e r i e s Q u i c k S t a r tVia the CAN ‐Logger Utility, user can set the CAN port operation mode and filter parameter of the module. Please refer to the following steps to configure the CAN ‐Logger series.1. Select the necessary CAN ‐Logger module and then press the “Configurate” buttom.Then the “Device Configuration” window will be popped up.C A N ‐L o g g e r s e r i e s Q u i c k S t a r t2. On the “Device Configuration” windows, user can set the CAN Bus parameter, and otherprarameters. The detail functions of these parameters are list below.[CAN Bus Parameters] “Port Enable” : Enable/Disable the CAN1/CAN2 port.“Silent Mode” : Set the CAN port into silent mode. When setting the CAN port into silentmode, the CAN port will just receive CAN messages, no CAN Ack command be sent to the CAN Bus.“Baud Rate”: CAN Bus baud rate in used. Via setting the ratary switch from ‘0’ ~ ‘8’, user canchange the CAN Bus baud rate from ‘10kbps’ to ‘1Mbps’. If you want to useuser ‐defined CAN baud rate, user can set the ratary switch to ‘9’, and then set the “Defined Baud Rate” parameter to the CAN baud rate that you need.“Defined Baud Rate”: CAN Bus baudrate used for user ‐defined. After set the CAN rotary switchto ‘9’, you can set this parameter to the baud rate you need.“Sample Point”: Sample point of CAN baud rate bit timing.“CAN ID Filter”: CAN message ID filter.[Mode]: Mode of CAN ID, can be set to 2.0A (11‐bit CAN ID) and 2.0B (29‐bit CAN ID). [Mask]: Mask CAN ID bits. Be use with [Arbitration] parameter. Bit value of 0 mean doesnot care the bit of corresponding “Arbitration CAN ID” and bit value of 1 means this bit need be matched with the corresponding bit of “Arbitration CAN ID”.[Arbitration]: Arbitration CAN ID bit. The CAN ID that you want to use for the CAN ID filter. [Example]1. All CAN ID passed.[Mode] = “2.0A” [Mask] = “000”[Arbitration] = “000”2. Filter all messages except ID of 0x123.[Mode] = “2.0A” [Mask] = “7FF”[Arbitration] = “123”3. Filter all messages except ID from 0x100 ~ 0x10F.[Mode] = “2.0A” [Mask] = “7F0”[Arbitration] = “100”[Other Parameters]“Device Real ‐time clock”: RTC time of the CAN ‐Logger device. This parameter is used forCAN ‐Logger device to log the received CAN messages into SD card.“RTC Battery Voltage”: Crrent battery voltage that RTC used. The battery valtage must bethe value between 2.2V DC to 3.6V DC .Step 4: Transmit, receive CAN messages and check CAN Bus stateBy using the CAN ‐Logger Utiltiy tool, user can transmit, receive CAN messages and check the CAN Bus state of the CAN ‐Logger devices.1. Connect with the selected CAN ‐Logger device.2. Transmit CAN messages, check received CAN messages and CAN Bus state.C A N ‐L o g g e r s e r i e s Q u i c k S t a r t3 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Core’s application and wiringCore(Ferrite) is useful to reduce ElectroMagnetic Interference(EMI) and anti ‐noise, it mainly uses forcommunication interface like CAN Bus and DC power supply line.。
Quick Start Guide for Data Logger说明书
INSTALL THE SOFTW AREInsert the datalogger software CD then the installation program should start automatically.Run the installation program Visit our websiteBrowse the CD-ROM through Windows.Detail operation procedure in PDF format Driver for USB type interface Exit the installation Install Software Website Browse CD-ROM ManualUSB DriverExitATT ACH THE INTERFACE & LOGGERonto interface and make the metal pointsof the interface & datalogger contacted well. While the datalogger contacts well with interface, the ID information of the datalogger will appear on main screen.If not, message will appear on screen.<< WARNING: Data Logger is notplug in interface module!>> COM. PORT SETUPFit the cable (RS232 port or USB port) to your computer by connecting USB port interface, be sure to install USB driver first.::::::A.B.C.D.E. F.8818P/8828P/8829PINTERFACE 8818PSelect icon for "Com. Port Setting"Data bits, Parity and Stop bits. Usually, it's COM1 for most PC. Select up to COM 8 for special systems. Select OK to accept setting changes, Cancel to abort and to exit com. port setting.Note:Always remember to select 9600baud rate.Click on icon to retrieve and to load a data file into this program.This program is designed to log up to 4K, 8K or 16K Sample readings.RETRIEVE FILE1324RS232ORLOGGER SETTINGSelect "Logger Set" button from main screen to set logger samplingparameters.The needed parameters are sample points, sample rate, start mode,unit and ID. If "Schedule" is selected as start mode, then start date and time need to be set as well. High/Low alarm setting are optional. To make sure the time of datalogger is correct, always remember to press "OK " at Clock Setting to make the time frame of logger is same as your local time. NOTE: The time of your PC must be correct.Please refer to below table for the available start mode of each type dataloggers.88335/88345/88355Need external temp.probe calibration 88375Need external RH probe calibrationTo select "Sleep" mode could make the logger LCD automatically turn off after sampling is finished. The selectable time frame is from 1 sec.to 12 hours.For few models, the external probe calibration data need to be keyed into logger through computer before start recording. The calibration data will be printed in a small note enclosed with goods. Please keep the note well. Please enter the values printed on the note into PC ( see right photo) and then press "SET" to save the values.Display ControlCommandsSettingT e m p e r a t u r e C h a r tH u m i d i t yC h a r tCursor StatusMessageRecord Number Time Set Data TableStatisticsPrint GraphGroupFiles LogoHelpCursor 1(red)Cursor 2(green)eg:88375Calibration ?Modeleg:88358835-1Air Temp.P Print out the data table to either a printer or a fax /internet application depending on available facilities.ress icon to view detailed data table which includes 1000 sample readings. DAT A TABLEClick on the right mouse button anywhere over the table control to activate a menu which contains Goto and Find menu items.Find You can search all numeric and text cells in the entire table, or in a selection range.Goto You can specify a target cell to go to, using its row and column indices.STA TISTICSPress icon to view histograms of data based on "Whole Range " basis or "Cursor Range " basis.Whole Range - S ample readings which have been logged.Cursor Range - S ample readings between two cursors.The right part indicates Maximum, Minimum, Mean and StandardDeviation (Std.Dev) values from the selected range.Maximum Minmium Mean Std.Dev85.141.472.011.6Mean :Average value of the logged records from selected range.DISPLAY CONTROLOffset - To set up from which sample reading you would like to start. Full range of 0000 to 7500 are selectable.Range - To set up the range of sample reading you would like to cover in the chart. There are 50, 250, 500, 1K, 2K, 4K, 8K for selection.0000250050007500502505001K2K 4K 8KAuthorization must be obtained from the supplier before returning. Returned with good packing against possible damage.The meter warrants to be free from defects in material andworkmanship for one year from the date of purchase. This warranty covers normal operation and does not cover batteries, misuse, abuse, alteration, tampering, neglect, improper maintenance, or damage resulting from leaking batteries. Proof of purchase is required for warranty repairs.RETURN AUTHORIZATIONWARRANTYTo select a folder and name to save the data. The windows " Save File " dialog box allows you to specify the file format to save the data,the file name to be called and where the file to be saved to.SAVE FILEStd. Dev.:Calculate each deviation between each value and Mean value; then, get an average figure from totalism deviation. GROUP FILESClick on its icon to view "Multi-Logger Monitor", which is designed to view and to compare different data files. Y ou may select and change the color of curve to refer to the file you retrieve by clicking the color block. You can print the screen data by clicking the printer icon at the right top corner.567The software also offers data selection function so you could set the conditions first and then press "GO " key to highlight the database.The selectable conditions are :Channel : select the data type you could like to analysis.Data Selection: AND/OR, select to decide the range selected below is AND or OR.Data Value : tick off and set the needed value range.Error: if Error code appear in data table, when tick off this item, the error code will be highlighted as well.Alarm color: pick up a color to highlight the selected data.Usage(Records): The software could help to count how many records is within the range you set.Counter ( Times): Help to count how many runs the data out of the selected range and then come back again.Besides the data table will be highlighted, below two information willbe counted automatically to help user doing detail analysis.82008/08/rev。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
无源探棒; 150 MHz,
用于 GDS-2102A/GDS-2104A
无源探棒; 250 MHz,
用于 GDS-2202A/GDS-2204A
无源探棒; 350 MHz,
用于 GDS-2302A/GDS-2304A
电源线 x1
选配
项目 以太网& SVGA 输出 GPIB 接口 DDS 信号发生器 8-通道逻辑分析仪
GTL-242
显示屏 5. 右侧菜单 7. 触发设置 9. 底部菜单 11. 通道/总线/
参考值/运算指示器
2. 触发状态 4. 日期和时间 6. 波形频率 8. 水平状态 10. 通道状态 12. 水平位置
前面板
描述
1. Hardcopy 键
产品介绍
本章节介绍了示波器的主要特点、外观和设置步骤。
主要特点
型号 GDS-2072A GDS-2102A GDS-2202A GDS-2302A GDS-2074A GDS-2104A GDS-2204A GDS-2304A 特点
带宽
输入通道
70MHz
2
100MHz
2
200MHz
2
300MHz
2
包括 8-通道逻辑分析仪卡(GLA-08) 和 8-通道逻辑分析仪探棒(GTL-08LA)
16-通道逻辑分析仪
包括 16-通道逻辑分析仪卡(GLA-16) 和 16-通道逻辑分析仪探棒(GTL-16LA)
选配
项目 8-通道逻辑分析仪卡 16-通道逻辑分析仪卡 8-通道逻辑分析仪测试探棒 16-通道逻辑分析仪测试探棒
2. 可调旋钮和选择键
3. 功能键
4. 自动设置, 运行/停止, 单次&默认键
5. 水平和搜索控制
6. 触发控制
7. 垂直控制
8. EXT 触发输入
9. 模拟通道输入
10. 运算, 参考值&总线键
11. USB Host, Demo 和接 12. 逻辑分析仪输入 地端子
13. 信号发生器输出 1 & 2 14. 开机键
8/16 通道数字输入、串行总线 (I2C, SPI, UART)和并行总线触发 • DDS 信号发生器模块(选配) • 分段存储: 优化内存,仅捕获重要
接口
的信号细节。高达 2048 个连续的 波形分段,捕获率 8ns。分段存储 可用于模拟和信号通道 • 强大的搜索功能: 可搜索不同的信 号事件
料号 82DS-2304AE01 82DS-2304AM01 GTP-070A-4 GTP-150A-2 GTP-250A-2 GTP-350A-2
依区域不同
料号 DS2-LAN DS2-GPIB DS2-FGN DS2-8LA
DS2-16LA
料号 GLA-08 GLA-16 GTL-08LA GTL-16LA
正常 & 反相 300V (DC+AC Peak), CAT I 1mV/div ~ 20mV/div : ±0.5V 50mV/div ~ 200mV/div : ±5V 500mV/div ~ 2V/div : ±25V 5V/div ~ 10V/div : ±250V
20MHz 20MHz 20MHz, 100MHz 20MHz, 100MHz, 200MHz +, -, ×, ÷, FFT, FFTrms, d/dt, ∫dt, √ FFT: 频谱幅度。可将 FFT 垂直 档位设为线性 RMS 或 dBV RMS FFT 窗函数:Rectangular, Hamming, Hanning, Blackman-Harris
70MHz
4
100MHz
4
200MHz
4
300MHz
4
• 8’’ TFT SVGA 显示屏 • 提供 MSO 和 DSO 机型,
70MHz~300MHz • 全系列 2GSa/s 实时采样率和
100GSa/s 等效采样率 • 深存储: 2M 点记录长度 • 80,000 次/秒波形捕获率
• 垂直灵敏度: 1mV/div~10V/div. • 逻辑分析仪模块(选配):
后置触发 精确度 实时采样率 等效采样率 记录长度 捕获模式 峰值侦测 平均次数 X-Y 模式 X-轴输入 Y-轴输入 相位移 光标和测量 光标 自动测量
光标测量 自动计数
控制面板功能 Autoset
最大 1000 div 时间间隔≥ 1ms 时±20 ppm 最大 2GSa/s 100GSa/s 2Mpts 正常, 平均, 峰值侦测, 单次 2ns (典型值) 2~256 可选
特殊规格
GDS-2072A & GDS-2074A 带宽(–3dB)
通道
DC 耦合: DC ~ 70MHz
AC 耦合: 10Hz ~ 70MHz 2 + EXT (GDS-2072A) 4 + EXT (GDS-2074A)
GDS-2102A & GDS-2104A 带宽(–3dB)
通道
DC 耦合: DC ~ 100MHz
3. 设置探棒衰减电压 x10 档
4. 按
键
5. 方波显示在屏幕中心
6. 按 类型
键,从底部菜单选择 Vector 波形
7. 旋转探棒调节点,尽可能平滑方波边沿
Over Compensation
Normal
Under Compensation
8. 完成示波器设置。可以开始使用示波器
规格
此规格适用条件:+20˚C~+30˚C,示波器热机至少 30 分 钟。
绿色/黄色: 蓝色: 棕色:
地线 零线 火线(相线)
导线颜色可能与插头/仪器中所标识的略有差异,请遵循如下操作:
颜色为黄绿色的线需与标有字母 E,或接地标志 ,或颜色为绿色/ 黄绿色的接地端子相连。 颜色为蓝色的线需与标有字母 N,或颜色为蓝色或黑色的端子相连。 颜色为棕色的线需与标有字母 L 或 P,或者颜色为棕色或红色的端子 相连。 若有疑问,请参照本仪器提供的用法说明或与经销商联系。 电缆/仪器需有符和额定值和规格的 HBC 保险丝保护:保险丝额定值 请参照仪器说明或使用手册。如: 0.75mm2 的电缆需要 3A 或 5A 的保 险丝。保险丝型号与连接方法有关,大的导体通常应使用 13A 保险 丝。 将带有裸线的电缆、插头或其它连接器与火线插座相连非常危险。若 已确认电缆或插座存在危险,必须关闭电源,拔下电缆、保险丝和保 险丝座,并且根据以上标准立即更换电线和保险丝。
• 在线帮助 • 64 MB 内部闪存
• USB host: 前面板和后面板, 用于存 储装置
• USB device: 后面板, 用于远程控制 或打印
• Demo 输出 • GPIB (选配) • RS232 • 校准输出 • SVGA 输出和以太网接口(选配)
包装明细
标配
项目 使用手册 CD 快速入门手册(本手册) 无源探棒; 70 MHz,
注意
注意: 产品在某一特定情况下或实际应 用中可能对产品本身或其它产品造成损
坏
高压危险
请参考使用手册
保护导体端子
大地(接地)端子
勿将电子设备作为未分类的废弃物处 理。请单独收集处理或联系设备供应商
英制电源线
在英国使用该仪器时,确保电源线符合以下安全说明。 注意: 导线/设备连接必须由专业人员操作
警告: 此装置必须接地: 导线颜色应与下述规则保持 一致:
GDS-2302A & GDS-2304A 带宽(–3dB)
通道
DC 耦合: DC ~ 300MHz
AC 耦合: 10Hz ~ 300MHz 2 + EXT (GDS-2302A) 4 + EXT (GDS-2304A)
常规
垂直 分辨率
输入耦合 输入阻抗 DC 增益精度*
极性 最大输入电压 偏移范围
带宽限制(-3dB) GDS-207XA GDS-210XA GDS-220XA GDS-230XA
波形信号处理
8位 1mV*~10V *:当垂直档位设为 1mV/div 时, 带宽自动限制在 20MHz AC, DC, GND 1MΩ// 16pF 选择 1mV/div 时, ± (5% ×|读值|+0.1div +1mV) 选择≥2mV/div 时, ± (3% ×|Readout|+0.1div +1mV) *:在零垂直位置,至少测量 16 个平均波形
触发 触发源
触发模式 触发类型
触发释抑范围 耦合 灵敏度
外部触发 范围 灵敏度 输入阻抗 水平 时基范围 前置触发
双通道机种: CH1 ,CH2, Line, EXT 四通道机种: CH1 ,CH2, CH3, CH4, Line, EXT MSO 机种: D0-D15 自动 (支持小于 100ms/div 的滚 动模式), 正常, 单次 边沿、脉冲宽度、视频、脉冲 矮波(Runt)、上升&下降、交 替、事件延迟(1~65,535 events) 、时间延迟 (10ns~10s)、逻辑*、总线*、*选 配逻辑分析仪 10ns~10s AC, DC, LF rej. , Hf rej. , Noise rej DC ~ 100MHz 约 1div 或 1.0mV 100MHz ~ 200MHz 约 1.5div 或 15mV 200MHz ~ 300MHz 约 2div 或 20mV
设置示波器
本章节介绍如何正确设置示波器,包括设置站立、安装 选配模块和探棒补偿。
倾斜站立
GDS-2000A 有两个可调橡胶支脚,可以将仪器调整到两 个预设位置。 1. 向前搬动支脚,仪器倾斜站
立
2. 向里收拢支脚,仪器直立