伟肯变频器参数
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
伟肯变频器参数
伟肯变频器参数VACON 45KW 500V
1 Basic Parameters
1.1 Min Frequency 0Hz
1.2 Max Frequency 50Hz
1.3 Accel Time 1 3.0s
1.4 Decel Time 2 3.0s
1.5 Multi Step1 10.0Hz
1.6 Multi Step2 50.0Hz
1.7 Current Limit 60.0A
1.8 U/f Ratio Select 2 / Programmable
/ None 1.9 U/f Optimization 0
1.10 Output Max Volta 500V
1.11 Motor Nom Freq 50Hz
1.12 Motor Nom Speed 1470 rpm 1.13 Motor Nom Currnt 77.0A 1.14 Supply Voltage 17 / 500 1.15 Param Conceal 0 / All Visible 1.16 Parameter Lock 0 / ChangeEnable 1.17 Basic Ref Select 2 / Panel
2 Input Signals
2.1 Start / Stop Logic 3 / StartP – StopP
2.2 Dia3 Function 6 / P/Pi Selection 2.3 Curr Ref Offset 0 / 0-20 mA 2.4 Ref Scal Min Val 0Hz
2.5 Ref Scal Max Val 0Hz
2.6 Ref Invert 0 / No Inversion 2.7 Ref Filter Time 0.10s 2.8 PI P Gain 0
2.9 PI P Time 0.00s
2.10 PI High Lim 0V
2.11 PI Low Lim 0V
2.12 PI Scale 0%
3 Output Signals
3.1 Iout Content 1 / Motor Freq 3.2 Iout Filter Time 1.00s 3.3 Iout Invert 0 / No Inversion 3.4 Iout Minimum 0 / 0 mA 3.5 Iout Scale 100%
3.6 DO1 Content 1 / Ready 3.7 RO1 Content 2 / Run
3.8 RO2 Content 3 / Fault 3.9 Freq Supv Lim 1 0 / Not Used 3.10 Freq Supv Val 1 0.0Hz
3.11 Opt Aout Invert 3 / MotorCurrent 3.12 Opt Aout Scale 100%
4 Drive Control
4.1 Ramp 1 Shape 0.0s
4.2 Ramp 2 Shape 0.0s
4.3 Accel Time 2 10.0s
4.4 Decel Time 2 10.0s
4.5 Brake Chopper 0 / No 4.6 Start Function 0 / Ramping 4.7 Stop Function 0 / Coasting 4.8 DC-Brake Current 38.5A 4.9 Stop DC-Brake t 0.00s
5 Prohibit Freq
5.1 Range 1 Low Lim 0.0Hz 5.2 Range 1 High Lim 0.0Hz
6 Motor Control
6.1 Control Mode 0 / Freq Control 6.2 Switching Freq 3.6Hz 6.3 Field Weakn Pnt 50Hz 6.4 Voltage at FWP 100%
6.5 U/f Mid Freq 3.0Hz
6.6 U/f Mid Voltg 0.00%
6.7 Zero Freq Voltg 0.00% 6.8 Overvolt Vontr 1 / On 6.9 Undervolt Vontr 1 / On
7 Protections
7.1 Reference Fault 0 / No Action 7.2 External Fault 0 / No Action 7.3 Phase Supervisn 2 / Fault 7.4 Earth Fault 2 / Fault 7.5 Motor Therm Prot 2 / Fault 7.6 MTP Fnom Current 100% 7.7 MTP F0 Current 45%
7.8 MTP Motor T 45.0min
7.9 MTP Fnom 35Hz
7.10 Stall Protection 1 / Warning 7.11 Stall Current 130%
7.12 Stall Time Lim 15.0s 7.13 Stall Freq Lim 25Hz 7.14 Underload Protect 0 / No Action 7.15 Up fnom Torque 50.0%
7.16 Up f0 Torque 10.0%
7.17 Up Time Limit 20.0%
8 Auto Restart
8.1 Number of Trials 0
8.2 Trial Time 30s
8.3 Start Function 0 / Ramping
9 UnderVoltage Con
9.1 UV Normal 1111
9.2 UV Delta Normal -1000 9.3 UV Expected Limi 8400。