WBR100-16A中文资料
Spears SUPER SOURCEBOOK - 一本塑料管道配件、阀门、管道和水泥类产品的完整目
R O D U C T S M A D E B YS P E A R S®M A N U F A C T U R I N G C O M P A N Y I N T H E U.S.A.F O R A L L Y O U R P L A S T I C P I P I NG N E E D SSSB-1-1011PA L LVisit our web site:T A B L O C A T O RC o n v e n i e n t “T a b L o c a t o r ” p a g e l e t s y o u q u i c k l y t h u m b t o e a c h c a t e g o r y m a t c h i n g s h a d e d t a b s i n t h e o u t e r m a r g i n o f e a c h p a g e .Understanding Column Header & Con À guration InformationA variety of Column Header layouts are used to list product part numbers, options, discount codes, and list price. The following are the mosttypical used:Typical Fitting Column Header label identi ¿ es the following product particulars:Part Number The number used to order the part.Size N ominal diameter of pipe with which the ¿ tting is to be used. NOTE: Fittings may be same size (only one sizedesignation) or reducing (multiple sizes designated).Standard Pack (Std Pk) The quantity of parts packaged in an individual box or bag.Master Carton (Mstr Ctn) The total quantity of parts contained in individual boxes or bags which are packaged together.Discount Code (Disc Code) I denti ¿ cation code for applicable discount to the list price of the product. NOTE: This is a Product Group code andis not a calculation of discount. Discount codes are not the same for all products contained in this price schedule.Price Each The designated list price of the product.Fitting Con À guration Drawings are accompanied by the product’s name and an abbreviated con ¿ guration description of the ¿ tting outlet connec-tions. Line drawing illustrations are general representations of the ¿ ttings in the group, but may not be an exact depiction of all con ¿ gurations listed. Line drawings are correlated to the con ¿ guration description. The drawing is read left to right for Elbow and Adapter con ¿ gurations. Tees have an additional outlet branch and are read left to right (run) then top (branch). Drawings for Wyes and Crosses are read top to bottom then left to right and bushings drawings are read as outside x inside con ¿ guration. The con ¿ guration description also correlates to the size designation. As with the nominal size designations, only one description is given when all outlets are the same. Reducing sizes list run con ¿ guration x branch con ¿ guration.Typical Valve Column Header label identi ¿ es the following product particulars. Headers are generally preceded by identi ¿ cation of material type and con ¿ guration descriptions. Again, variations exist according to product type and con ¿ gurations.Size The nominal diameter of the pipe with which the valve is to be used.Seal Type Designated elastomer seal (O-ring, Seat, Diaphragm, etc.)(i.e., EPDM, Viton ®) NOTE: Part Number and List Price are typically speci ¿ ed under the seal type columns.C ertain products may have other column header designations under which part number and pricing are speci-¿ ed in a similar manner.Standard Pack (Std Pk) The quantity of parts packaged in an individual box or bag.Master Pack (Mstr Pk) The total quantity of parts contained in a single packaging of multiple Standard Packs.Discount Code (Disc Code) I denti ¿ cation code for applicable discount to the list price of the product. NOTE: This is a Product Group code andis not a calculation of discount. Discount codes are not the same for all products contained in this price schedule.Valve Illustrations may be as photos or line drawings. Illustrations are general representations of the valve or product speci ¿ ed, but may not depict all con ¿ gurations listed.Page IIIPart NumberSizeStdPkMstr CtnDisc CodePrice Each402-0033/850200040.97402-0051/250300040 1.01402-0073/4500401.58ExampleProduct Name ------------------- TeeAbbreviated ----------------------- Soc x Fipt Configuration DescriptionIn this example, outletdescription is “Soc x Fipt”which indicates:1. Socket x 2. Socket x3. Female Iron Pipe Thread123Product Type(Page Heading)Typical Presentation PhotoSocket StylePressure Rating @ 73°F (23°C) Water 1/2" - 4"6" - 8"Flanged235 psi 150 psi 150 psiMaximum Service TemperaturePVC=140°F (60°C)CPVC=200°F (93°C)Temperature/Pressure De-ratings ApplyTechnical DataExampleSize EPDMViton ®Std PkMstr PkDisc CodePVC Industrial1/21829-005XX.XX1829-005XX.XX118101Socket EndsPricePart NumberMaterialEnd ConnectorSpears ® Super SourcebookViton ® is a Registered Trademark of DuPont Dow ElastomersSpears ® Super SourcebookTABLE OF CONTENTS1Low VOC Solvent Cements & Primers1Spears® Low VOC Solvent Cements & Primers 1PVC Low VOC Cements2Low VOC Solvent Primers & Cleaners4PVC Schedule 40 Fittings5Tees 590° Ells7Non 90° Ells 9Wyes 11Crosses 12Couplings 13Adapters15Riser Extension 17Reducer Bushings 17Caps 18Plugs 19Unions19Glue-on Saddles20Clamp-On & Hot-Tap Saddles22Mechanical Clamp-On Transition Saddles 29Schedule 40 Tank Adapters30PVC White Schedule 40 - Hard to Find Configurations -Pool & Spa Specialties31Pool & Spa Fittings31True Union 2000 Standard Ball Valve - PVC White 32PVC Pool Butterfly Valves33UVR Schedule 40 Fittings34UVR Sch 40 Fittings34PVC Gray Schedule 40 Fittings36PVC Gray Sch 40 Fittings36PVC Black Schedule 40 Fittings40PVC Black Schedule 40 Fittings40PVC Clear Schedule 40 Pipe & Fittings42PVC Clear Sch 40 Pipe & Fittings42Compression & Repair Fittings44Schedule 40 Repair Fittings 44Repair Couplings45Short Repair Couplings 46Compression Couplings47Compression Male Adapters49Irrigation & Hose Filters50Filters50Reverse Flow Filters51In-line Tee Style Filters and Reverse In -line Tee Style Filters 53Hose Filters55PVC Irrigation Specialty Products57• Hose Fittings • Solvent Weld For Flexible PVC Hose 57• Hose Fittings • For 1/2" Polyethylene (.580 I.D.) Hose 57Hose Adapters58Irrigation Accessories 59Sprinkler Accessories59Dri-Splice Wire Connectors61PVC Irrigation Manifold Systems62High Strength 1" Manifold Systems63Turf Swivel Joints64Turf Swivel Kits 65Turf Swivel Joints66Made in the U.S.A.Page IVProgressive Products from Spears ®Innovation and TechnologySpears®Super SourcebookTABLE OF CONTENTSCompact Turf Swivel Joints66 Pressure Regulated Swivel Joints68 Turf Swivel Joint Replacement Parts68 Pipe Flanges70 Pipe Flanges70 Flange Bolt Kits72 Full-Faced Flange Gaskets73 Ball Valves75 True Union 2000 Standard Ball Valve - PVC White75 True Union 2000 Standard Ball Valves75 CWV Ball Valves77 Utility Ball Valves77 Single Entry Ball Valves78 Electro Actuated True Union 2000 Standard Ball Valve79 Electro Actuated Compact 2000 Ball Valve79 Check Valves80 Utility Swing Check Valves80 True Union Utility Swing Check Valves80 Compression Utility Swing Check Valves81 Utility Spring Check Valves81 True Union Utility Spring Check Valves82 PVC In-line Adjustable Spring Check Valves8283 EverTUFF® TURF™ Fittings For Golf Course & Turf Applications83 EverTUFF® TURF™ PVC Tees83 EverTUFF® TURF™ PVC Elbows83 EverTUFF® TURF™ PVC Couplings83 EverTUFF® TURF™ PVC Special Reinforced Female Adapters83 EverTUFF® TURF™ PVC Male Adapters83 EverTUFF® TURF™ PVC Reducer Bushings84 EverTUFF® TURF™ CPVC Tees84 EverTUFF® TURF™ CPVC Elbows84 EverTUFF® TURF™ CPVC Couplings84 EverTUFF® TURF™ CPVC Special Reinforced Female Adapters84 EverTUFF® TURF™ CPVC Male Adapters84 EverTUFF® TURF™ CPVC Reducer Bushings84 EverTUFF® TURF™ Mechanical Clamp-on Transition Saddles85 EverTUFF® TURF™ Mechanical Clamp-on Transition Saddles85 EverTUFF® TURF™ Swing Joint Riser Assemblies86 EverTUFF® TURF™ Swing Joint Riser Assemblies88 Turf Swivel Joints94 Turf Swivel Kits95 Turf Swivel Joints96 Compact Turf Swivel Joints96 Pressure Regulated Swivel Joints98 Turf Swivel Joint Replacement Parts98 PVC Irrigation Manifold Systems100 High Strength 1" Manifold Systems101 Four-In-One • Cut-Off Nipples102 Four-In-One • Cut-Off Nipples102 PVC Irrigation Specialty Products103• Hose Fittings • Solvent Weld For Flexible PVC Hose103• Hose Fittings • For 1/2" Polyethylene (.580 I.D.) Hose103 Irrigation Accessories104 Hose Adapters105 Sprinkler Accessories106 Dri-Splice Wire Connectors107 Page V Spears® Manufacturing CompanyProgressive Products from Spears®Innovation and TechnologySpears ® Super SourcebookTABLE OF CONTENTSFilters108Reverse Flow Filters109In-line Tee Style Filters and Reverse In -line Tee Style Filters 111Hose Filters 113PVC Low Head PIP Fabricated Fittings, Risers & Accessories115Couplings 115Non 90° Ells 11590° Ells115Reducer Bushings 115Adapters115Glue-on Saddles 116Caps 117Tees 117Crosses118Riser Extension 118Wyes119DISTRIBUTING GATE RISER 120RITE FLO RISER120DISTRIBUTING GATE REPAIR UNIT 120RITE FLO RISER REPAIR UNIT120PVC 80, 100 & 125 PSI PIP Fabricated Fittings126Tees 12690° Ells129Non 90° Ells 130Couplings132Reducer Couplings 133Crosses 135Wyes137Surface Reducers138Stub Surface Reducers 138Caps139Glue-on Saddles 139Pipe Flanges140PVC Class 63, 100, 125, 160 & 200 IPS Fabricated Fittings & Molded Class 125141Tees 14190° Ells145Non 90° Ells 145Couplings148Reducer Couplings 149Crosses150Surface Reducers 151Caps152Glue-on Saddles152Class 125 Molded Fittings154155Barbed Insert Fittings155Insert Fittings156160PVC, CPVC & PE Nipples160PVC, CPVC & PE Nipples160Four-In-One • Cut-Off Nipples164Four-In-One • Cut-Off Nipples164Made in the U.S.A.Page VIProgressive Products from Spears ®Innovation and TechnologySpears®Super SourcebookTABLE OF CONTENTS165 Industrial Pipe165 Schedule 80 PVC Industrial Pipe165 Low VOC Solvent Cements & Primers166 Spears® Low VOC Solvent Cements & Primers166 PVC Low VOC Cements167 CPVC Low VOC Cements168 Low VOC Solvent Primers & Cleaners169 PVC Schedule 80 Fittings170 Tees170 90° Ells172 Non 90° Ells173 Wyes175 Crosses177 Couplings177 Adapters180 Reducer Bushings181 Caps183 Plugs183 Unions184 Clamp-On & Hot-Tap Saddles188 Mechanical Clamp-On Transition Saddles196 Tank Adapters197 Expansion Joints200 Pipe Flanges201 Van Stone Style Flange Replacement Split Rings204 Flange Insulating Joints205 Flange Bolt Kits205 Full-Faced Flange Gaskets206 PVC Compression & Repair Fittings207 Schedule 80 Repair Fittings207 Compression Couplings207 Gauge & Instrument Fittings, Schedule 80 Specialty Fittings for Sensor Probes209 Gauge Guards209 Gauge & Instrument Fittings Schedule 80 Specialty Fittings for Sensor Probes210 Ball Valves211 True Union 2000 Industrial Ball Valves211 True Union 2000 Industrial Vented/Bleach Ball Valves212 True Union 2000 Industrial 3-Way Ball Valves213 Tee-Style "Zero Dead-Leg" Ball Valves215 True Union 2000 Standard Ball Valves216 True Union 2000 Industrial Retrofit Ball Valves -Replaces Other Brand Valves217 True Union 2000 Industrial Retrofit Ball Valves -Replaces Spears® ''Regular Style'' Valves218 True Union 2000 Standard Retrofit Ball Valves -Replaces Other Brand Valves219 True Union 2000 Standard Retrofit Ball Valves -Replaces Spears® ''Regular Style'' Valves219 True Union Ball Valves (Regular Style)220 Single Entry Ball Valves221 Compact 2000 Ball Valves221 Compact Ball Valves (Regular Style)222 Utility Ball Valves223 Lab Ball Valves223 Check Valves224 True Union 2000 Industrial Ball Check Valves224 True Union Ball Check Valves (Regular Style)225 Foot Valve Screens226 Y-Check Valves226 Butterfly Check Valves228 Industrial Swing Check Valves229 Page VII Spears® Manufacturing CompanyProgressive Products from Spears®Innovation and TechnologySpears ® Super SourcebookTABLE OF CONTENTSIndustrial Swing Check Valve Accessory and Repair Kits 230Diaphragm Check Valves231PVC In-line Adjustable Spring Check Valves 231Gate Valves232Gate Valves232Plug Gate Valves233Butterfly Valves234Butterfly Valves234Lug Insert Butterfly Valves 235True Lug Butterfly Valves236Large Diameter Butterfly Valves 237Wafer Butterfly Valves237Globe and Needle Valves238Globe Valves 238Needle Valves238Diaphragm Valves239Diaphragm Valves239Y-Pattern Valves241Y-Pattern Valves241Industrial Strainers & Filters243In-line Tee-Style Filters 243Y-Strainers245True Union Y-Strainers 247Basket Strainers 250Suction Strainers252253Industrial Pipe253CPVC Industrial Pipe253Low VOC Solvent Cement & Primer254CPVC Low VOC Cements254Low VOC Solvent Primers & Cleaners255CPVC Schedule 80 Fittings256Tees 25690° Ells258Non 90° Ells 259Wyes 261Crosses 262Couplings 263Adapters265Reducer Bushings 266Caps 267Plugs 268Unions268Clamp-On & Hot-Tap Saddles 272Tank Adapters 280Expansion Joints 283Pipe Flanges284Van Stone Style Flange Replacement Split Rings 285Flange Insulating Joints 286Flange Bolt Kits286Full-Faced Flange Gaskets287Gauge & Instrument Fittings, Schedule 80 Specialty Fittings for Sensor Probes288Gauge Guards288Gauge & Instrument Fittings Schedule 80 Specialty Fittings for Sensor Probes289Ball Valves290True Union 2000 Industrial Ball Valves290True Union 2000 Industrial Vented/Bleach Ball Valves291Made in the U.S.A.Page VIIIProgressive Products from Spears ®Innovation and TechnologySpears®Super SourcebookTABLE OF CONTENTSTrue Union 2000 Industrial 3-Way Ball Valves292 Tee-Style "Zero Dead-Leg" Ball Valves294 True Union 2000 Standard Ball Valves295 True Union 2000 Industrial Retrofit Ball Valves -Replaces Other Brand Valves296 True Union 2000 Industrial Retrofit Ball Valves -Replaces Spears® ''Regular Style'' Valves297 True Union 2000 Standard Retrofit Ball Valves -Replaces Other Brand Valves298 True Union 2000 Standard Retrofit Ball Valves -Replaces Spears® ''Regular Style'' Valves298 True Union Ball Valves (Regular Style)299 Compact 2000 Ball Valves300 Compact Ball Valves (Regular Style)301 Utility Ball Valves302 Lab Ball Valves302 Check Valves303 True Union 2000 Industrial Ball Check Valves303 True Union Ball Check Valves (Regular Style)304 Foot Valve Screens304 Y-Check Valves305 Butterfly Check Valves306 Industrial Swing Check Valves307 Diaphragm Check Valves308 Gate Valves309 Gate Valves309 Plug Gate Valves310 Butterfly Valves311 Butterfly Valves311 Lug Insert Butterfly Valves312 True Lug Butterfly Valves313 Large Diameter Butterfly Valves314 Wafer Butterfly Valves314 Globe and Needle Valves315 Globe Valves315 Needle Valves315 Diaphragm Valves316 Diaphragm Valves316 Y-Pattern Valves318 Y-Pattern Valves318 Industrial Strainers & Filters319 In-line Tee-Style Filters319 Y-Strainers321 True Union Y-Strainers322 Basket Strainers324326 Special Reinforced (SR) & Metal Thread Transition Fittings & Adapters326 PVC White Special Reinforced (SR) Fittings327 PVC White Brass Thread Fittings328 PVC Gray Special Reinforced (SR) Fittings329 PVC Gray Brass Thread Fittings333 CPVC Gray Special Reinforced (SR) Fittings334 CPVC Gray Brass Thread Fittings338 CPVC Orange Special Reinforced (SR) Fittings339 CPVC Orange Brass Thread Fittings340 CPVC Orange Brass Grooved Coupling Adapter341 CTS CPVC Tan Special Reinforced (SR) Fittings342 CTS CPVC Tan Brass Thread Fittings342 CTS CPVC Tan Gasket Sealed Thread Fittings343 Blue 75™ Thread Sealant343 Page IX Spears® Manufacturing CompanyProgressive Products from Spears®Innovation and TechnologySpears ® Super SourcebookTABLE OF CONTENTS344Polypropylene Schedule 80 Natural & Black SR Threaded Fittings344Polypropylene Schedule 80 Natural SR Threaded Fittings 345Polypropylene Schedule 80 Black SR Threaded Fittings345Gauge & Instrument Fittings, Schedule 80 Specialty Fittings for Sensor Probes347Gauge Guards347Needle Valves348Needle Valves348Check Valves349Industrial Swing Check Valves349Butterfly Valves350Polypropylene Butterfly Valves350Large Diameter Butterfly and Diaphragm Valves351Large Diameter Butterfly Valves 351Diaphragm Valves352353Ball Valves353True Union 2000 Industrial Ball Valves353True Union 2000 Industrial Vented/Bleach Ball Valves 355True Union 2000 Industrial 3-Way Ball Valves 357Tee-Style "Zero Dead-Leg" Ball Valves 361True Union 2000 Standard Ball Valves362True Union 2000 Industrial Retrofit Ball Valves -Replaces Other Brand Valves364True Union 2000 Industrial Retrofit Ball Valves -Replaces Spears® ''Regular Style'' Valves 365True Union 2000 Standard Retrofit Ball Valves -Replaces Other Brand Valves366True Union 2000 Standard Retrofit Ball Valves -Replaces Spears® ''Regular Style'' Valves 367True Union Ball Valves (Regular Style)367Single Entry Ball Valves 369Compact 2000 Ball Valves370Compact Ball Valves (Regular Style)371Lab Ball Valves 372Utility Ball Valves 373CWV Ball Valves374Swing Check Ball Valve 374CTS Valves375Ball Valve Accessories & Repair Kits376Check Valves386True Union 2000 Industrial Ball Check Valves 386True Union Ball Check Valves (Regular Style)388Foot Valve Screens 389Y-Check Valves389Y-Check Valve Repair Kits 392Butterfly Check Valves393Butterfly Check Valve Repair Kits 395Industrial Swing Check Valves395Industrial Swing Check Valve Accessory and Repair Kits 397Utility Swing Check Valves398True Union Utility Swing Check Valves 398Compression Utility Swing Check Valves 399Utility Spring Check Valves400True Union Utility Spring Check Valves 401Diaphragm Check Valves401PVC In-line Adjustable Spring Check Valves 402Industrial PVC Backwater Valves403Made in the U.S.A.Page XProgressive Products from Spears ®Innovation and TechnologySpears®Super SourcebookTABLE OF CONTENTSSump Pump Swing Check Valve407 Quiet Check Valve407 Swing Check Ball Valve408 Gate Valves409 Gate Valves409 Plug Gate Valves410 Gate Valve Accessories & Repair Kits411 Butterfly Valves413 PVC Pool Butterfly Valves413 Butterfly Valves413 Lug Insert Butterfly Valves414 True Lug Butterfly Valves -Zinc Plated Lugs416 True Lug Butterfly Valves -SS Lugs417 Polypropylene Butterfly Valves419 Large Diameter Butterfly Valves419 Wafer Butterfly Valves420 High Purity TFM-Lined Butterfly Valves421 Butterfly Valve Accessories & Repair Kits422 Globe Valves430 Globe Valves430 Needle Valves431 Needle Valves431 Diaphragm Valves432 Diaphragm Valves432 Diaphragm Valve Repair Kits436 Y-Pattern Valves437 Y-Pattern Valves437 Y-Pattern Valve Repair Kits440 Backwater, Sewage & Sump Pump Specialty Valves441 Sewer Disconnect441 Industrial PVC Backwater Valves442 Sump Pump Swing Check Valve446 Quiet Check Valve446 Swing Check Ball Valve447448 Actuated Valve Information448 Electro Actuated Compact 2000 Ball Valve451 Electro Actuated True Union 2000 Standard Ball Valve452 Electro Actuated True Union 2000 Industrial Ball Valve453 Premium Actuated True Union 2000 Industrial Ball Valve -Electric454 Premium Actuated True Union 2000 Industrial Ball Valve -Pneumatic455 Premium Actuated Standard Butterfly Valve -Electric457 Premium Actuated Standard Butterfly Valve -Pneumatic458 Premium Actuated Lug Insert Butterfly Valve -Electric460 Premium Actuated Lug Insert Butterfly Valve -Pneumatic461 Premium Actuated True Lug Butterfly Valve -Electric463 Premium Actuated True Lug Butterfly Valve -Pneumatic464 Premium Actuated Diaphragm Valve - Electric466 Unitized Actuated Diaphragm Valve - Pneumatic with Plastic Housing469 Premium Actuated Diaphragm Valve - Pneumatic475489 Irrigation & Hose Filters489 Filters489 Hose Filters490Page XI Spears® Manufacturing CompanyProgressive Products from Spears®Innovation and TechnologySpears ® Super SourcebookTABLE OF CONTENTSIn-line Tee Style Filters and Reverse In -line Tee Style Filters 491Reverse Flow Filters 493Industrial Strainers & Filters496In-line Tee-Style Filters 496Y-Strainers498True Union Y-Strainers 500Basket Strainers 504Suction Strainers507508Expansion Joints508Fabricated Expansion Joints 508Elastomer Expansion Joints 510Repair Couplings512Short Repair Couplings514515PVC DWV Drain Waste Vent Fittings515PVC DWV Drain Waste Vent Fittings 515Sewer Disconnect525Industrial PVC Backwater Valves526PVC Schedule 40 & 80 DWV Fabricated Fittings529Tees 52990° Ells529Non 90° Ells 530Couplings531Reducer Couplings 531Crosses 532Wyes533Sanitary Tees 536Adapters 537Caps 537Plugs 537Cleanouts537538EverTUFF® CPVC CTS Fittings, Valves & Pipe538EverTUFF® CPVC CTS Fittings, Valves & Pipe538543Low-Extractable Piping For Ultra-Pure Water Systems543Low-Extractable Piping For Ultra-Pure Water Systems544551LabWaste™ CPVC Corrosive Waste Drainage Systems551LabWaste™ CPVC Corrosive Waste Drainage Systems551LabWaste™ Standard CPVC & HDPE Neutralization Tanks559LabWaste™ Standard HDPE Round Neutralization Tanks 561LabWaste™ Standard CPVC Round Neutralization Tanks 5621-Gallon CPVC Dilution Tanks563Made in the U.S.A.Page XIIProgressive Products from Spears ®Innovation and TechnologySpears®Super SourcebookTABLE OF CONTENTS1-Gallon CPVC Dilution Traps564 Pedestrian Traffic Covers565 Heavy-Duty Pedestrian Traffic Covers565 Vehicular Traffic Covers565 Optional Inspection Manhole Ports & Tank Extensions566 Tank Extensions566 Limestone Chips for Acid Neutralization Tanks566567Lab Specialty Products567 Lab Ball Valves567 Needle Valves567 Gauge Guards569 Lab Fixtures571575PVC & CPVC Duct & Fabricated Duct Fittings575 PVC & CPVC Round Seamless Duct576 PVC & CPVC Cold Rolled Fabricated Duct576 PVC & CPVC Duct Fittings577584Double Containment584 Tees585 90° Ells587 45° Ells589 Couplings591 Access Tees593 Closure Fittings595 Isolation Couplers596 Termination Fittings598 Centralizers600 Ball Valve Box With Valve601 Ball Check Valve Box With Valve603 Diaphragm Valve Box With Valve605 Clamp-on Saddles for Leak Detection Sensors607608PVC Low Head PIP Fabricated Fittings, Risers & Accessories608 Tees608 90° Ells608 Non 90° Ells608 Couplings608 Reducer Bushings609 Adapters609 Crosses609 Riser Extension610 Wyes611 Caps611 Glue-on Saddles612 DISTRIBUTING GATE RISER613 RITE FLO RISER613 DISTRIBUTING GATE REPAIR UNIT613 Page XIII Spears® Manufacturing CompanyProgressive Products from Spears®Innovation and TechnologySpears ® Super SourcebookTABLE OF CONTENTSRITE FLO RISER REPAIR UNIT 613PVC 80, 100 & 125 PSI PIP Fabricated Fittings619Tees 61990° Ells622Non 90° Ells 623Couplings625Reducer Couplings 626Crosses 628Wyes630Surface Reducers631Stub Surface Reducers 631Caps632Glue-on Saddles 632Pipe Flanges633PVC Class 63, 100, 125, 160 & 200 IPS Fabricated Fittings & Molded Class 125634Tees 63490° Ells638Non 90° Ells 638Couplings641Reducer Couplings 642Crosses643Surface Reducers 644Caps645Glue-on Saddles645Class 125 Molded Fittings647PVC Schedule 40 & 80 DWV Fabricated Fittings648Tees 64890° Ells648Non 90° Ells 649Couplings650Reducer Couplings 650Crosses 651Wyes652Sanitary Tees 655Adapters 656Caps 656Plugs 656Cleanouts656PVC Schedule 40 & 80 Low Pressure Fabricated Fittings657Tees 65790° Ells657Non 90° Ells 658Couplings659Reducer Couplings 659Crosses 660Caps 661Plugs661662PVC & CPVC Metric Fittings, Unions & Valves662PN16 PVC Metric Fittings 666PN16 CPVC Metric Fittings666Class 10/12 PVC & CPVC Metric Fittings & Class 150 Flanges667PVC ASTM Schedule 40 Socket x BSP Adapter Fittings (White & Gray)668PVC Transition Unions669True Union Ball Valves (Regular Style)670PVC & CPVC True Union 2000 Industrial Ball Valves 671PVC & CPVC True Union 2000 Standard Ball Valves672PVC & CPVC True Union 2000 Industrial 3-Way Horizontal Diverter Ball Valves673Made in the U.S.A.Page XIVProgressive Products from Spears ®Innovation and TechnologySpears ®Super SourcebookTABLE OF CONTENTS676s e v l a V l l a B l a c i t r e V y a W -3 l a i r t s u d n I 0002 n o i n U e u r T C V P C & C V P 186s e v l a V k c e h C l l a B l a i r t s u d n I 0002 n o i n U e u r T C V P C & C V P PVC & CPVC Gate Valves682PVC & CPVC Diaphragm Valves 683PVC Irrigation Manifold Systems684Pipe686Industrial Pipe686CPVC Industrial Pipe686786e p i P n o i t u b i r t s i D r e t a W d l o C & t o H S T C C V P C Schedule 80 PVC Industrial Pipe 688Schedule 40 Clear Pipe 688Low Extractable PVC Pipe689986e p i P m e t s y S e g a n i a r D e t s a W e v i s o r r o C C V P C ™e t s a W b a L 096e p i P r e l k n i r p S e r i F C V P C ®d r a u G e m a l F PVC & CPVC Round Seamless Duct690196tc u Dde t a c i r b a F d e l l o R d l o C C V P C & C V P Solvent Cements & Thread Sealants692Blue 75™ Thread Sealant692Blue 75™ Thread Sealant692Low VOC Solvent Cements, Primers & Accessories693396s r e m i r P & s t n e m e C t n e v l o S C O V w o L ®s r a e p S PVC Low VOC Cements 694CPVC Low VOC Cements 696ABS Low VOC Cements697ABS to PVC Transition & Mult 896s t n e m e C C O V w o L e s o p r u P i Low Extractable Low VOC Cement 699007s r e n a e l C & s r e m i r P t n e v l o S C O V w o L Applicators & Accessories701FlameGuard® CPVC Fire Sprinkler Products706FlameGuard® CPVC Fire Sprinkler Piping Products706707s t c u d o r P g n i p i P r e l k n i r p S e r i F C V P C ®d r a u G e m a l F FlameGuard® CPVC Fire Sprinkler Piping 217st c u d o r P Page XVSpears ® Manufacturing CompanyProgressive Products from Spears ®Innovation and TechnologyPart Number Index 714AppendicesAppendix A - Basic Abbreviations Used in this CatalogAppendix B - Applicable Industry Standards & Test Methods Appendix C - Product Approvals & CertificatesAppendix D - Recommendations for Installers & Users Appendix E - Special Information on Fabricated FittingsAppendix F - Sustainable Solutions for Total Piping System Needs Appendix G - Discount CodesSchedule 40 Fittings & AccessoriesSpears® Low VOC Solvent Cements & Primersz User Friendly with reduced fumes and odor for well-being of pipe installers.z NSF ® Certified & Listed for use in piping applications such as potable water, turf, irrigation, pool & spa, industrial, plumbing, DWV, and/or sewer,plus special applications including fire protection, chemical waste, and ultra-pure water.z Meets ASTM Standards for solvent cements and primers used for plastic pipe installation.z Environmentally friendly. LEED ® Compliant (Leadership in Energy and Environmental Design). Credit can be gained through the use of Spears ®Low VOC products. This program, developed by the US Green Building Council, uses SCAQMD Rule 1168 as a benchmark to qualify one credit toward LEED ® certification for green building.z Low VOC emissions comply with SCAQMD Rule 1168/316A z 3-Year Shelf LifeEssential solvent cements developed for contractors' essential needs in joining PVC, CPVC and ABS pipe and fittings.Low VOC PVC CementsRegular, Medium, heavy and extra heavy bodied cements are specifically formulated for PVC pipe in virtually every schedule and in sizes with interference fit to 30" diameter.PVC-00 CLEAR: Regular bodied, fast setting PVC cement for all classes and schedules (except Schedule 80) with interference fit through 4". Excellent for plumbing, DWV, irrigation, electrical conduit, pool &spa and PVC foam core pipe. Listings: ASTM D2564,NSF ®-PW, DWV, SW, U.P. Code.PVC-00 Clear Regular Body PVC CementPart Number Size Std Pk Mstr Ctn Disc Code PriceEach PVC00C-0051/4 Pint 240705 5.85PVC00C-0101/2 Pint 2407058.50PVC00C-020Pint 12070513.10PVC00C-030Quart 12070522.10PVC00C-040Gallon6070571.75PVC-02 CLEAR: Regular bodied, fast setting PVC cement for all classes and schedules (except Schedule 80) with interference fit through 4" diameter. Goes on clear, dries clearest and is slightly thicker than PVC-00. Excellent for plumbing, DWV, irrigation, electrical conduit, pool & spa and PVC foam core pipe. Listings:ASTM D2564, NSF ®-PW, DWV, SW, U.P. Code.PVC-02 Clear Regular Body PVC CementPart Number Size Std Pk Mstr Ctn Disc Code Price Each PVC02C-0051/4 Pint 240705 6.50PVC02C-0101/2 Pint 2407059.45PVC02C-020Pint 12070514.55PVC02C-030Quart 12070524.55PVC02C-040Gallon6070579.65PVC-05 CLEAR:Medium bodied, fast setting, PVC cement for all classes and schedules with interference fit through 6" diameter and Schedule 80 through 4"diameter in industrial, plumbing, DWV, irrigation,electrical conduit, pool & spa and PVC foam core pipe.Can be used without primer on non-pressure systems if local code permits. Listings: ASTM D2564, NSF ®-PW, DWV, SW, U.P. Code.PVC-05 Clear Medium Body PVC CementPart Number Size Std Pk Mstr Ctn Disc Code PriceEach PVC05C-0051/4 Pint 240705 6.60PVC05C-0101/2 Pint 2407059.55PVC05C-020Pint 12070516.75PVC05C-030Quart 12070526.65PVC05C-040Gallon6070590.80PVC-21 BLUE:Medium bodied, fast setting, highstrength PVC cement. It is suitable for use on rigid PVC with interference fit Schedule 40 thru 6" and Schedule 80 thru 4". Can be used without primer on PVC Schedule 40 and SDR pressure water piping systems through 4" if local code permits. Do not use PVC-21 without primer in any other application,schedule, or size such as Schedule 80 industrial applications. Listings: ASTM D2564, NSF ®-PW, DWV,SW, U.P. Code.PVC-21 Blue Medium Body PVC CementPart Number Size Std Pk Mstr Ctn Disc Code PriceEach PVC21B-0051/4 Pint 2407057.05PVC21B-0101/2 Pint 24070511.60PVC21B-020Pint 12070519.85PVC21B-030Quart 12070533.35PVC21B-040Gallon60705114.65Made in the U.S.A.NOT FOR DISTRIBUTION OF COMPRESSED AIR OR GAS Page 1Progressive Products from Spears ®Innovation and Technology。
biopower 中文使用说明书
BIOPOWER 中文使用说明书.经销商制造商仅限 RxREF 1601147-001REF 1303393-001REF 1601008-001REF 1600692-001REF 1601009-001REF 1600631-001REF 1500984-005REF 1301575-001REF 1502329-002REF 1307727-010选配件REF 1601008-001REF 1600692-001REF 1600598-001REF 1600785-001REF 1600786-001 REF 1600052-001REF 1303393-001 REF 1601009-001REF 1600631-001REF 1301575-001REF 1502329-010REF 1307727-010REF 1307312-010REF 1500984-010REF 1501738-010REF 1501635-010REF 1501621-010 REF 1307031-001Bien-Air Dental 参考目录1符号 (2)1.1BIOPOWER主机符号释义 (2)1.2BIOPOWER配件符号释义 (2)2产品简介、用途与表示法 (3)2.1产品简介 (3)2.2预期用途 (3)2.3预期患者人群 (3)2.4预期用户 (3)2.5预期医疗条件 (3)2.6患者禁忌症与警告 (3)2.7事故情形 (3)2.8表示法和章节链接 (3)3警告与使用预防措施 (4)3.1基本信息 (4)3.2警告 (4)4描述 (5)4.1BIOPOWER 系统概览 (5)4.2提供的套装 (6)4.3选配件 (6)4.4技术参数 (6)4.5性能 (7)4.6环境保护和处置信息 (7)4.7电磁兼容性 (技术描述) (7)4.7.1使用预防措施 (7)4.7.2电磁兼容性警告 (7)4.7.3电磁兼容性 – 辐射和抗干扰能力 (8)5安装 (10)5.1 安装 BIOPOWER 系统 (11)5.2开/关过程 (11)6界面总览 (12)6.1BIOPOWER模式 (12)6.2旋钮功能概览 (12)6.3声音警告 (13)7治疗 (14)7.1治疗画面描述 (14)7.2执行治疗:步骤P1和P2 (14)7.3执行治疗:步骤P3、P4和P5 (15)8设置 (16)8.1MX-i LED第3代微型电动马达速度 (16)8.2MX-i LED第3代微型电动马达扭矩 (16)8.3MX-i LED第3代微型电动马达旋转方向 (16)8.4灌注流量 (17)8.5弯手机转速比 (17)9特殊模式 (18)10 错误和故障处理列表 (20)10.1安全警告 (运行中) (20)10.2设备运行错误 (21)11 维护 (22)11.1维修 (22)11.2清洁与灭菌 (22)11.3重要信息 (23)11.4更换保险丝 (23)12 保修条款 (24)1.1BIOPOWER 主机符号释义1.2BIOPOWER 配件符号释义保险丝。
界面剂配方
界面剂配方标题:界面剂配方1. 简介界面剂是一种常见的化学品,用于改善液体和固体之间的黏附性能。
它们被广泛应用于各个行业,包括医药、农业、化妆品和食品等领域。
本文将介绍界面剂的配方和制备方法。
2. 界面剂的分类界面剂可分为阳离子界面剂、阴离子界面剂、非离子界面剂和两性界面剂四种类型。
不同类型的界面剂适用于不同的应用领域。
3. 阳离子界面剂配方阳离子界面剂主要用于表面活性剂、洗涤剂和消毒剂等产品中。
以下是一种常见的阳离子界面剂配方示例:材料:- 十六烷基三甲基氯化铵- 水制备方法:1. 在容器中加入适量的水,加热至80°C。
2. 将十六烷基三甲基氯化铵逐渐加入到水中,并充分搅拌,直到溶解。
3. 将溶液冷却至室温,过滤去除杂质,得到阳离子界面剂。
4. 阴离子界面剂配方阴离子界面剂常用于洗涤剂、柔软剂和乳化剂等产品中。
以下是一种常见的阴离子界面剂配方示例:材料:- 十二烷基硫酸钠- 水制备方法:1. 在容器中加入适量的水,加热至50°C。
2. 将十二烷基硫酸钠逐渐加入到水中,并充分搅拌,直到溶解。
3. 将溶液冷却至室温,过滤去除杂质,得到阴离子界面剂。
5. 非离子界面剂配方非离子界面剂常用于乳化剂、稳定剂和润滑剂等产品中。
以下是一种常见的非离子界面剂配方示例:材料:- 辛基苯聚氧乙烯醚- 水制备方法:1. 在容器中加入适量的水,加热至60°C。
2. 将辛基苯聚氧乙烯醚逐渐加入到水中,并充分搅拌,直到溶解。
3. 将溶液冷却至室温,过滤去除杂质,得到非离子界面剂。
6. 两性界面剂配方两性界面剂具有阳离子界面剂和阴离子界面剂的特点,常用于乳化剂、表面活性剂和润滑剂等产品中。
以下是一种常见的两性界面剂配方示例:材料:- 辛酸盐和三甲基胺羟基乙基- 水制备方法:1. 在容器中加入适量的水,加热至75°C。
2. 将辛酸盐和三甲基胺羟基乙基逐渐加入到水中,并充分搅拌,直到溶解。
铝塑板洗涤剂参数
铝塑板洗涤剂参数
铝塑板洗涤剂的参数因具体产品而异,但一般会包括以下几个方面:
1. 主要成分:通常由表面活性剂、助剂、缓蚀剂等组成,能够有效地去除铝塑板表面的污渍和油渍。
2. 适用范围:适用于各种类型的铝塑板表面,如吊顶、墙面、门头招牌等。
3. 使用方法:将适量的铝塑板洗涤剂涂在干净的抹布上,均匀地擦拭铝塑板表面,然后用清水冲洗干净。
4. 注意事项:使用时应避免与眼睛、皮肤接触,存放于阴凉干燥处,远离火源。
5. 性能特点:具有快速去污、防锈、除味、保养等功能,能够保持铝塑板表面的光亮和美观。
6. 包装规格:一般为瓶装或桶装,容量有25公斤、150克等不同规格。
7. 保质期:一般为1-3年。
具体参数可能会因品牌和型号而有所不同,建议查看具体产品的说明书或咨询生产商。
派克液压中文样本
液压注意 – 用户方责任 错误或不当地选择或使用本样本或有关资料阐述的产品,可能会导致人生伤亡及财产损失! 本样本以及其它由派克汉尼汾公司及其子公司、销售公司与授权分销商所提供的资料,仅供用户专业技术人员在对产品和系统的选型进行深入调查考证时参考。
用户应全面分析自身设备的运行工况、适用的工业标准,并仔细查阅现行的样本,以详细地了解产品及系统的相关信息,通过自己的分析和试验,对产品及系统的独立的最终选择负责,确保能满足自身设备的所有性能、耐用性、维修型、安全性以及预警功能等要求。
对于派克或其子公司或授权分销商而言,应负责按用户提供的技术资料和规范,选择和提供适当的元件或系统,而用户则应负责确定这些技术资料和规范对其设备的所有运行工况和能合理预见的使用工况是否充分和准确。
目录目录页次概述 1 订货代号 2 技术参数 4 变量控制器 5 控制选项 “C”, 压力限定(恒压)变量控制器 5 控制选项 “L”, 负载传感及压力限定变量控制器 6 控制选项 “AM”, 带遥控口的标准型先导式压力限定变量控制器 7 控制选项 “AN”, 带ISO 4401 NG06先导阀安装界面的先导式压力限定变量控制器 8 控制选项 “AE”及“AF”, 带电磁比例调节的先导式压力限定变量控制器 9 控制选项 “AMT”, “ALT”及“LOT”, 带最高压力限定的扭矩限定(恒功率)变量控制器 10 P1性能特性 11典型流量特性 11 典型总效率特性 13 典型轴输入功率特性 15 典型噪声特性 18 典型轴承寿命 20 PD性能特性 22典型流量特性 22 典型总效率特性 24 典型轴输入功率特性 26 典型噪声特性 29 典型轴承寿命 31 安装尺寸 33 P1/PD 018 33 P1/PD 028 36 P1/PD 045 40 P1/PD 060 44 P1/PD 075 49 P1/PD 100 54 P1/PD 140 59 变量控制器安装尺寸 65 可提供的扩展的液压产品 75派克汉尼汾备记派克汉尼汾概述简介, 优点派克汉尼汾简介 • 开式回路用轴向柱塞式变量液压泵 • 中压,连续工作压力280 bar • 高驱动转速型,适用于行走机械; 低噪声型,适用于工业应用 • 静音及高效的控制效能 优点 • 总结构尺寸紧凑 • 低噪声• 流量脉动小,进一步降低噪声• 采用弹性密封,不使用密封垫,从而避免外泄漏的产生• 总效率高,功耗小,减小发热• 采用带无泄漏调节装的简单变量控制器 • 符合SAE 及ISO 标准的安装法兰及油口 • 采用圆锥滚柱轴承,使用寿命长 • 全功率后驱动能力• 后部或侧面油口配置可选• 泄油口的配置对水平安装及驱动轴向上垂直安装均适用• 带有最大及最小排量调节选项 • 具有壳体至吸口单向阀选项,可延长轴封寿命 • 使用、维修方便 脉动容腔技术下列图表所示为侧向油口配置P1/PD 18, 28及45泵采用 “脉动容腔” 技术的效果,脉动容腔可降低泵出口处的压力脉动幅值40-60%,这样,无需增加成本来加装噪声缓冲元件,便可大大降低液压系统的整体噪声,P1系列 PD 系列出口压力p / bar平均压力脉动 / b a rP1 045出口压力脉动2600 rpm 无脉动容腔2600 rpm 带脉动容腔订货代号18 ml, 28 ml, 45ml派克汉尼汾P 类型 01 驱动轴 转向R 5密封材料E 油口配置0 壳体-吸口 单向阀 0 排量调节 018 排量 S 安装法兰 及油口 S 轴封 M 应用范围A 设计系列0 通轴驱动选项 C0控制选项0附加控制选项 00油漆 00修改代号系列 P D * 仅适用于045排量, “S”型安装法兰及油口00 标准型, 无修改M2 按要求修改 代号修改代号 * 适用于028及045排量 ** 仅适用于045排量 代号设计系列 A 现行设计系列5 氟碳橡胶 (FPM) 代号密封材料 A 82-2 SAE A M33x2 M27x2 BSPP 1/4”, 3/8” 101-2 SAE B M42x2 M27x2 BSPP 1/4”, 1/2” 101-2SAE B M48x2M33x2Ø38/25DN51/25BSPP 1/4”, 1/2”B ISO M33x2 M27x2 BSPP 1/4”,3/8”ISO M42x2 M27x2 BSPP 1/4”, 1/2” ISO M48x2M33x2Ø38/25DN51/25BSPP 1/4”, 1/2”代号 018排量 028排量 045排量 安装法兰及油口 安装 法兰 螺纹 油口 辅助 油口 安装 法兰 螺纹 油口 辅助 油口 安装法兰螺纹油口法兰 油口辅助 油口 S 82-2 SAE A SAE 16/12 SAE 4/6 101-2 SAE B SAE 20/12 SAE 4/8 101-2SAE B SAE 24/16Ø38/2561系列SAE 4/10M ISO M33x2 M27x2 M12x1.5 M16x1.5 ISO M42x2 M27x2 M12x1.5 M22x1.5 ISO M48x2M33x2Ø38/25DN51/25M12x1.5M22x1.5代号 018驱动轴 028驱动轴 045驱动轴 01 SAE A 11T 花键SAE B-B 15T 花键 SAE B-B 15T 花键02 SAE 19-1平键Ø0.75” SAE B-B 平键Ø1” SAE B-B 平键Ø1” 08— SAE B 13T 花键 SAE B 13T 花键 04 ISO/DIN 平键, Ø20ISO/DIN 平键, Ø25ISO/DIN 平键, Ø25 06 SAE A 9T 花键— — PD 工业液压用 代号 系列P1 行走机械用 代号 排量 018 18 ml/rev (1.10 in 3/rev) 028 28 ml/rev (1.71 in 3/rev) 045 45 ml/rev (2.75 in 3/rev) 代号 类型 P 开式回路用变量柱塞泵 U*通用 代号应用范围 S 工业液压 (PD) M 行走机械 (P1) R 顺时针 (右转)L 逆时针 (左转)代号 转向 代号 轴封 S 单唇轴封 * 并不具有控制功能,仅在运输时予以防护,详情见第7页的控制说明。
好马滕制造公司 L.P. 用户信息手册 - 包装气电热水器说明书
Goodman Manufacturing Company, L.P .5151 San Felipe, Suite 500, Houston, TX 77056© 2004, 2007, 2009 - 2011, 2014 - 2015 Goodman Manufacturing Company, L.P.USER’S INFORMATION MANUALP ACKAGE G AS -E LECTRICInstaller -Affix this manual, Installation Guide, and Warranty adjacent to the appliance.Owner -Read and keep all product literature in a safe place for future reference.RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.HI-116E 7/152S IGNAL W ORDSDear Homeowner, please recognize the following safety infor-mation. This information will alert you to the potential for per-sonal injury.- Indicate hazards or unsafe practices which result in severe personal injury or death.Before using this manual, check the serial plate for propermodel identification.The installation and servicing of this equipment must be performed by qualified, experienced technicians only.G ENERAL I NFORMATIONU NIT L OCATIONThis unit is approved only for an outdoor installation. See the installation instructions for the required clearances to the unit. It is important that safety measures are taken in the surrounding area of the unit.Gutters or deflectors must be installed on the roof to prevent water from shedding on the unit.1.An area must be available to reach the unit in a clear and unobstructed path.2.The unit area and the vicinity of any other gas appliances must be kept clear and free of combustible materials, gaso-line, and other flammable vapors and liquids. Also, do not store or use flammable items such as paint, varnish, or lac-quer in the area.3.The combustion air supply must not be contaminated by prod-ucts containing chlorine or fluorine, as they could corrode the heat exchanger. If you need further information on this sub-ject, contact your installing dealer or another qualified ser-vicer.4.Familiarize yourself with the controls that turn off the gas and electrical power to the unit.5.Establish a regular service and maintenance schedule to ensure efficient and safe operation of the unit.6.The unit must be placed where no runoff water from higher ground can collect in the unit.U NIT I NSTALLATIONExamine the unit installation to determine the following:1.The flue hood connector is in place and is physically sound without holes or excessive corrosion.2.The mounting pad support of the unit is sound.3.There are no obvious signs of deterioration of the unit.4.The burner flames are stable, soft and blue, (dust may cause orange tips but must not be yellow). The flames should ex-tend directly outward from the burner without curling, floating,or lifting off. To examine, turn on the electrical power and gas.Set the room temperature to the maximum setting.BurnerNOTE: If a strong wind is blowing, it may not be possible to perform the flame inspection.A IR REQUIREMENTSSince the gas/electric unit is installed completely in the outdoors, the depletion of combustion air is highly improbable. To ensure an adequate supply of combustion air, do not allow the combus-tion air inlet or the flue hood outlet to become blocked by leaves, snow, rubbish, or insect (wasps) nests. Never block the con-densing unit section in the winter with covers. Blocking of this section would prevent an adequate amount of combustion air from reaching the furnace section.Great care has been taken in the design and manufacture of your unit to provide for your comfort and safety. Be aware of the possibility that some problems with your unit or other gas-fired appliances could cause flue gases to be present in your building. These flue gases could include carbon monoxide.3T HERMOSTA TThis unit will not operate properly without a good quality, correctly installed thermostat. It is very important that the thermostat be located where it can best “sense” the average room temperature. Be sure the thermostat is not exposed to hot or cold drafts or to hot or cold spots on the wall, such as those received from outside walls, walls with pipes inside, or from openings into the attic. No matter the type or style, thermostat operation is basically the same. The most widely used types will control both heating and cooling functions and will have a Fan Switch with Auto and ON settings. On Auto, the Circulating Air Blower will cycle on/off, but if switched to ON it will run constantly.For Dual Fuel units (GPD/APD), a Dual Fuel thermostat with an outdoor temperature sensor is recommended for optimal opera-tion.IMPORTANT NOTE: To avoid the possibility of damage to the unit heat exchanger, do not set the thermostat fan switch to ON (constant fan operation) during the heating season without first consulting the installer of the unit or another qualified servicer. There are thermostats that automatically switch from Heating to Cooling, or with night setbacks. The night setback, or multiple setback type, will lower the temperature at night or during the day when the building is unoccupied.Propane (LP) Gas Installations OnlyFor units operating on propane gas, please review the following warnings before use.O PERATING INSTRUCTIONSH EATING S TART U PTo put your unit into operation, follow the steps listed below.1.Close the external manual gas shutoff valve.2.Turn off the electrical power to the unit.3.Set the room thermostat to the lowest possible setting.4.Remove the heat exchanger door on the side of the unit byremoving screws.5.This unit is equipped with an ignition device which automati-cally lights the burner. Do not try to light the burner by hand.6.Move the gas control switch to the OFF position. Do not useexcessive force.7.Wait five minutes to clear out any gas. Then smell for gas,including near the floor as some types of gas are heavier than air.8.If you smell gas following the five minute waiting period instep 7, immediately follow the instructions on the cover of this manual. If you do not smell gas after five minutes, move or rotate the gas control switch to the ON position. The switch should turn easily. Do not use excessive force.9.Reinstall the burner compartment door.10.Open the external manual gas shutoff valve.11.Turn on the electrical power to the unit.12.Adjust the thermostat to a setting above room temperature.13.After the burners are lit, set the thermostat to desired tem-perature.H EATING S HUT D OWNTo shut down operation, follow the steps listed below.1.Set the thermostat to the lowest setting.2.Turn OFF electrical power to the unit.3.Remove the heat exchanger door on the side of the unit byremoving screws.4.Move the gas control switch to the OFF position. Do not useexcessive force.5.Close the external manual gas shutoff valve.6.Reinstall the heat exchanger door.7.If cooling and/or air circulation is desired, turn ON the electri-cal power.C OOLING O PERATIONCooling operation may be obtained as follows:1.Place the room thermostat selector switch in the COOL po-sition (or AUTO, if available, and if automatic changeover from cooling to heating is desired).2.Set the room thermostat to the desired temperature.3.If cooling system does not energize, wait five minutes. Thesystem startup may be delayed by the short-cycle protector feature of the ignition control board. Check the manual reset devices on the rollout limit, as described in this manual.OUTLET Gas ValveOn/OffSelectorSwitchWhite-Rodgers Model 36F224SelectorSwitchINLET OUTLETWhite-Rodgers Model 36G22High RegulatorWhite-Rodgers Model 36G54Honeywell Model VR8215 (Single-Stage)S AFETY C IRCUITSA number of safety circuits are employed to ensure safe and proper unit operation. These circuits serve to control any poten-tial safety hazards and, as inputs in the monitoring and diagnosis of abnormal operation.S ECONDARY L IMITThe secondary limit control is located on the blower housing and monitors blower compartment temperatures. It is a normally closed (electrically), automatic reset, temperature activated sensor. This limit guards against overheating as a result of insufficient conditioned air passing over the heat exchanger. It deenergizes the gas valve if the blower fails.NOTE: If the power to the unit is interrupted during the heating cycle, it may cause the secondary limit to trip. Once the blower compartment temperature drops below the limit reset temperature, the limit will automatically reset.Secondary Limit ControlR OLLOUT L IMITThe rollout limit is a normally-closed (electrically), manual-reset, temperature-activated sensor. It is mounted on the burnerbracket and monitors the burner flame. If there is an improper draw of burner flames into the heat exchanger, the rollout limit will detect it and shut off gas flowing to the burners. Contact a qualified servicer to check the unit before resetting this device.Rollout Protection on Burner Bracket56C OMPRESSOR P ROTECTIOND EVICESThis gas/electric package unit includes components which are designed to protect the compressor against abnormal operat-ing conditions.NOTE: The operation of the indoor blower will not be affected by any compressor protection devices.If, during a call for cooling, the indoor fan runs and circulates room temperature air while the compressor and outdoor fan do not operate:1.Wait five minutes, as a protection device may be holding the compressor off.2.Check the room thermostat to see if it is correctly set.3.If the room thermostat is correctly set, call a qualified servicer to determine if one of the compressor protection devices has opened.S HORT -C YCLE P ROTECTORA short-cycle protector is built into the ignition control. Each time the compressor is off for less than 3 minutes, the short-cycle protector will delay compressor startup for up to 3 minutes. This protects the compressor from improper operation.On Dual Fuel units (GPD/APD), the short-cycle protector will delay the compressor 5 minutes.NOTE: These units are not designed to provide mechanical cooling at outdoor temperatures below 50°F. If low ambient cooling is needed, consult a qualified servicer.I GNITERThe unit has an electronic ignition device which lights the burners automatically. Never try to light the burners by hand. It also has an induced draft blower to exhaust combustion prod-ucts.I NDOOR A IR C IRCULATOR B LOWERKeep the blower access door panel in place except for inspec-tion and maintenance.R OUTINE M AINTENANCEIf you perform maintenance on the unit yourself, remember that certain mechanical and electrical knowledge, skills and tools are required to perform unit maintenance. Personal injury or death may result If you are not properly trained. You should call your installing dealer or place of purchase if you are uncertainabout your ability to perform maintenance.A NNUAL I NSPECTIONYour package unit should be inspected by a qualified installer,or service agency at least twice every year. This check should be performed before the heating and cooling seasons begin. This will ensure that adequate combustion air is being drawn and the vent system is working properly. Particular attention should be paid to the following items. Repair as necessary.•Check physical support of the unit. Ensure it is sound with-out any sagging, cracks, or gaps, around the base.•Check for obvious signs of deterioration of the unit.•Flue Hood and Combustion Air Inlet. Check for blockage (wasp nest, etc.) and corrosion.Flue Hood•Return Air Connection. Check for physical soundness and ensure that the connection is firmly sealed to the package unit casing.•Heat exchanger. Check for corrosion and/or obstructions within the heat exchanger passageways.•Burners. Check for proper ignition, burner flame, and flame sense.•Wiring. Check electrical connections for tightness and/or corrosion. Check wires for damage.•Filters. Check that filters are clean and in the proper place-ment in the unit or duct system.•Louvers. Inspect air inlet louvers inside the heat exchanger compartments. Ensure the area is clean and free of dirt and debris.R EPLACING OR C LEANING F ILTERIMPORTANT NOTE: Never operate unit without a filter installed as dust and lint will build up on internal parts resulting in loss of efficiency, equipment damage and possible fire.A return air filter is not supplied with this unit; however, there must be a means of filtering the return air. The filter(s) may be located in the return air duct(s). Consult with your installing dealer for the actual location of the return air filter(s) in your unit.A dirty filter is the most common cause of inadequate heating or cooling performance. Filter inspection should be made at least every two months; more often if necessary because of local conditions and usage.Dirty throwaway filters should be discarded and replaced with a new, clean filter. Dirty permanent filters should be washed with water, thoroughly dried and sprayed with a filter adhesive before being reinstalled. (Filter adhesives may be found at many hard-ware stores.) Permanent filters should last several years. How-ever, should one become worn or uncleanable, it should be replaced.When installing a new filter or reinstalling an old one, always make certain the air flow arrows on the filter point in the proper direction.C LEAN O UTSIDE C OIL (Q UALIFIED S ERVICER O NLY)The coil with the outside air flowing over it should be inspected annually and cleaned as frequently as necessary to keep the finned areas free of leaves, grass, seeds, and debris.C ONDENSER, E VAPORATOR, AND I NDUCED D RAFT M OTORS Bearings on the air circulating blower motor, condenser motor and the combustion fan motor are permanently lubricated. No additional oiling is required.C OMPRESSORThe compressor motor is hermetically sealed and does not require additional oiling.S AFETY L ABELSNOTE: If safety labels are missing or illegible, contact the installing dealer.To obtain the proper safety labels, the Model and Serial Number of the unit must be supplied. These numbers are recorded on the nameplate of the unit. For convenience, record this information here:MODEL NUMBER:_____________________________________SERIAL NUMBER:_____________________________________78S AFETY L ABELSF OR A DDITIONAL I NFORMATIONMost questions can be answered by your local dealer. If you have other matters that cannot be resolved locally,or you need additional information regarding other heating and cooling products offered by us - please call:CONSUMER INFORMA TION LINE:TOLL FREE1-877-254-4729 (U.S. only)emailusat:******************************fax us at: (731) 856-1821(Not a technical assistance line for dealers.)________________Outside the U.S., call 1-713-861-2500.(Not a technical assistance line for dealers.)Your telephone company will bill you for the call.SAFETY LABELS9SAFETY LABELS10SAFETY LABELS11Goodman Manufacturing Company, L.P. 5151 San Felipe, Suite 500, Houston, TX 77056 12。
Crouse-Hinds Arktite Heavy Duty WBR插孔接收器说明说明书
MATING PLUG:The WBR accepts standard Crouse-Hinds ®Arktite Heavy Duty plugs:AMPS DESCRIPTION CAT ALOG #3W4P, Aluminum AP J3485303W4P, Krydon NP J34853W4P, Aluminum AP J6485603W4P, Krydon NP J64853W4P, Aluminum AP J104871003W4P, Krydon NP J10487APPLICATIONWBR Series interlock receptacles are designed to mount to an enclosure and interface with a safety switch or breaker that is installed inside the enclosure.The WBR Interlock Receptacle interfaces with the switch or breaker mechanism to prevent pluginsertion or withdrawal under load.The WBR Receptacle provides connection and distribution ofsecondary electrical power (600V or less) between a power source and portable or stationary electrical equipment.IF 1404 • 11/99Copyright ©1999, Cooper Industries, Inc.Page 1ARKTITE ®HEAVY DUTY INTERLOCK RECEPTACLE WBR SERIES, MODEL M4Installation & Maintenance InformationIF 1404DESCRIPTIONThe WBR is shipped ready to install, including mounting hardware.The WBR6442is shown below (Figure 1) with spring door.TheWBR6442 S752 series is epoxy coated with screw cap and bead chain for NEMA 4X hose down requirements.Receptacle screw cap for NEMA 4ConductorGround Interlock Rear ViewNEMA 3R NEMA 4X EPOXY COATEDAMPS DESCRIPTIONCAT ALOG #CAT ALOG #30A 3W4P, Aluminum, 600VAC WBR3442WBR3442 S75260A 3W4P, Aluminum, 600VAC WBR6442WBR6442 S752100A3W4P, Aluminum, 600VACWBR10442WBR10442 S752Figure 1CAUTION The WBR Series Receptacle should be installed,inspected,operatedand maintained by qualified and competent personnel.WARNINGElectrical power must be turned OFF before and during installation and maintenance.INSTALLATIONThe WBR is designed to mount to the bottom of a sheet metal,stainless steel or cast enclosure.1.Attach WBR to enclosure using four (4) mounting screws provided.2.Check alignment of interlock rod and receptacle interlock arm.Interlock rod end should be flush to flat surface of receptacle interlock arm, preventing movement of enclosure main switch handle.3.Attach greenground wire to ground lug inside enclosure (Figure 2).WARNINGBefore assembling a WBR Series Receptacle, a wiring pattern must be established for your system.Locations having different voltages, frequencies or types of current (AC or DC) MUST NOT have interchangeable attachment plugs per section 210-7F of National Electrical Code and/or per Rule 26-700 (4) of Canadian Electrical Code.* For each system the same colored wire must be put into the same numbered contact on all plugs and receptacles in that system.This will assure correct system polarity and eliminate the possibility of equipment damage and/or personal injury due to misphasing or shorts.4.Attach black conductors to switch, fuse block or breaker inside enclosure (Figure 3).Tighten terminal lugs to manufacturers recommended torque value.5.Test for proper operation by inserting plug.Receptacle handle should release and cause plug to be locked in place.Main power handle can now be turned “ON”.Plug should not be able to be withdrawn.WARNINGReceptacle handle must not be able to travel towards “release”position with main switch “on”.Risk of defeating interlock feature if receptacle handle travels too far towards “release”position.MAINTENANCEWARNINGAlways disconnect primary power source before opening the enclosure for inspection or service.1.Frequent inspection should be made.A schedule for maintenance checks should be determined by the environment and frequency of use.It is recommended that it should be at least once a year.2.Perform visual, electrical and mechanical checks on all components, on a regular basis.Visually check for undue heating evidenced by discoloration of wires or other components, damaged or worn parts or leakage evidenced by water or corrosion in the interior.Electrically check to make sure that all connections are clean and tight, and that contacts in the components make or break as required.Mechanically check that all parts are properly assembled,and that operating mechanisms move freely.WARNINGIf any part of these plugs and/or receptacles appears to be broken or shows signs of any damage DISCONTINUE USE IMMEDIATELY.Replace, or properly repair, the item(s)BEFORE continuing service.!!!Figure 2Figure 3!!All statements, technical information and recommendations contained herein are based on information and tests we believe to be reliable.The accuracy or completeness thereof are not guaranteed.In accordance with Crouse-Hinds "Terms and Conditions of Sale", and since conditions of use are outside our control,the purchaser should determine the suitability of the product for his intended use and assumes all risk and liability whatsoever in connection therewith.Cooper Industries Inc.IF1404Crouse-Hinds DivisionRevision 2PO Box 4999, Syracuse, New Y ork 13221 • U.S.A.Revised 11/99Copyright©1999, Cooper Industries, Inc.Supercedes 9/98!。
WBR1-450A中文资料
Type WBR 85 ºC, Industrial Grade, Axial Leaded, Aluminum85 ºC, Industrial GradeType WBR capacitors are the preferred choice for many varied industrial applications because they have high capacitance and extended life characteristics. The rugged construction delivers the high vibration resis-tance required in industrial applicationsHigh capacitance Extended lifeRugged construction High vibration resistance••••HighlightsSpecificationsCapacitance Range:Voltage Range:Capacitance Tolerance:Operating Temperature Range:Leakage Current: Ripple Current Multipliers: 1.0 to 5,000 µF16 to 450 Vdc16 to 50 Vdc -10 + 150%, 75 to 350 Vdc–10 + 100%, 450 Vdc –10 + 50%–40 ºC +85ºC16-75 Vdc ≤ 0.01CV + 10 µA150-450 Vdc ≤ 0.03CV + 20 µA45 ºC 55 ºC 65 ºC 75 ºC 85 ºC 95 ºC 105 ºC 1.50 1.46 1.321.171.000.790.50Ambient TemperatureFrequency 60 Hz 120 Hz 400 Hz 1000 Hz 10 kHz 50 kHz 100 kHz 0-60 Vdc 0.85 1.00 1.10 1.15 1.15 1.15 1.1561-200 Vdc 0.83 1.00 1.15 1.20 1.20 1.20 1.20201-450 Vdc0.801.001.151.301.301.301.30Load Life:Shelf Life:Vibration: 2,000 h @ +85 ºC∆ Capacitance ±20% ∆ ESR 150% of limit ∆ DCL 100% of limit500 h @ 85 ºC∆ Capacitance ±20% ∆ ESR 150% of limit ∆ DCL 100% of limit10 to 55 Hz; 0.06” and 10 g max, 2 h in each planeOutline DrawingComplies with the EU Directive 2002/95/EC requirement restricting the use of Lead (Pb), Mercury (Hg), Cadmium (Cd), Hexavalent chromium (Cr(VI)), PolyBrominated Biphenyls (PBB) and PolyBrominated Diphenyl Ethers (PBDE).Type WBR 85 ºC, Industrial Grade, Axial Leaded, AluminumPart Numbering SystemRatingsWBR 500—16A EType Capacitance Voltage Lead Epoxy Endseal WBR500 = 500 µF16 = 16 VdcA = 1.5" 20 AWG E = Epoxy Blank = See tableBlank = No epoxyRippleMax Case Catalog Max ESR @ 85 ºC Size Cap Part Number 120 Hz 120 HzD x L (µF)(Ω)(A)(Inches)16 Vdc ( 20 Vdc Surge )100WBR100-16A 5.300.0570.340.76250WBR250-16A 2.100.1180.340.88500WBR500-16A 1.100.2700.40 1.001000WBR1000-16A 0.530.4200.40 1.322000WBR2000-16A 0.270.6600.47 1.573000WBR3000-16A 0.180.8200.52 1.834000WBR4000-16A 0.13 1.0000.65 1.835000WBR5000-16A 0.11 1.2000.65 1.8325 Vdc ( 30 Vdc Surge )10WBR10-25A 48.000.0180.280.5725WBR25-25A 19.000.0310.280.5750WBR50-25A 9.500.0440.340.76100WBR100-25A 4.800.0740.340.76250WBR250-25A 1.800.1550.40 1.00500WBR500-25A 0.950.2800.40 1.321000WBR1000-25A 0.480.4500.47 1.572000WBR2000-25A 0.230.7200.65 1.8335 Vdc ( 40 Vdc Surge )100WBR100-35A 4.400.0860.400.88150WBR150-35A 2.950.1140.40 1.00300WBR300-35A 1.450.1950.47 1.32500WBR500-35A 0.870.2850.52 1.671000WBR1000-35A 0.440.4500.54 1.672000WBR2000-35A 0.220.9100.65 1.833000WBR3000-35A 0.15 1.1500.74 1.6950 Vdc ( 65 Vdc Surge )1WBR1-50A 390.000.0100.280.572WBR2-50A 195.000.0120.280.575WBR5-50A 77.000.0140.280.5710WBR10-50A 39.000.0200.280.5725WBR25-50A 15.500.0350.340.7650WBR50-50A 7.700.0600.40 1.88100WBR100-50A 3.900.1400.40 1.00150WBR150-50A 2.500.1600.40 1.00250WBR250-50A 1.500.2200.40 1.32500WBR500-50A 0.770.3400.52 1.571000WBR1000-50A 0.390.5300.65 1.831500WBR1500-50A 0.250.7400.65 1.8375 Vdc ( 95 Vdc Surge )150WBR150-75A 2.500.1800.47 1.32275WBR275-75A 1.300.2800.52 1.57500WBR500-75A 0.720.4000.651.83RippleMax Case Catalog Max ESR @ 85 ºC Size Cap Part Number120 Hz 120 Hz D x L (µF)(Ω)(A)(Inches)150 Vdc ( 175 Vdc Surge )4WBR4-150A 78.000.0180.340.88 5WBR5-150A 62.000.0200.340.88 8WBR8-150A 39.000.0300.400.88 10WBR10-150A 31.000.0340.400.88 16WBR16-150A 19.500.0450.40 1.00 20WBR20-150A 15.500.0500.40 1.32 30WBR30-150A 10.500.0850.40 1.57 40WBR40-150A 7.800.0960.47 1.32 50WBR50-150A 6.200.1050.47 1.57 60WBR60-150A 5.200.1300.65 1.57 80WBR80-150A 3.900.1550.65 1.83 100WBR100-150A 3.100.1900.65 1.83 150WBR150-150A2.050.2300.74 1.69180 Vdc ( 250 Vdc Surge )125WBR125-180A 2.300.3000.74 1.69 250 Vdc ( 300 Vdc Surge )4WBR4-250A 64.000.0350.40 1.008WBR8-250A 32.000.0560.40 1.32 12WBR12-250A 21.500.0620.40 1.32 16WBR16-250A 16.000.0650.47 1.57 20WBR20-250A 12.500.0750.47 1.57 30WBR30-250A 8.400.1050.52 1.57 40WBR40-250A 6.300.1250.52 1.83 50WBR50-250A 5.000.1400.65 1.83 60WBR60-250A 4.200.1800.65 1.83 80WBR80-250A3.100.2000.74 1.69 350 Vdc ( 400 Vdc Surge )4WBR4-350A 51.000.0360.40 1.00 8WBR8-350A 26.000.0500.47 1.32 20WBR20-350A 10.000.0900.52 1.57 40WBR40-350A 5.100.1350.65 1.83 450 Vdc ( 525 Vdc Surge )1WBR1-450A 205.000.0230.40 1.00 2WBR2-450A 102.000.0300.40 1.00 4WBR4-450A 51.000.0380.47 1.57 5WBR5-450A 40.000.0420.47 1.57 8WBR8-450A 26.000.0530.47 1.57 10WBR10-450A 20.000.0580.52 1.57 12WBR12-450A 17.000.0620.65 1.83 16WBR16-450A 12.500.0840.65 1.83 20WBR20-450A 10.000.1050.65 1.83 30WBR30-450A6.700.1300.741.69。
卫泉系列产品简介说明A
基本配置:无电系列
1)世韩50g低压膜 2)豪华双水龙头 3)3.2塑胶压力桶 4)自动冲洗 适用于:家庭厨房做饭 及饮用水
使用条件:原水压力达 到2.5公斤方可使用
规格参数:
出水量:16L/h 规格:320×420×100 无电式
卫泉RO纯水系列产品及说明
WQ-RO1
基本配置:
卫泉RO商用系列产品及说明
WQ-RO200G
基本配置: 1)自动冲洗 2)外置11G压力桶 3)适合100-150人左右 饮水使用。
规格参数: 出水量:31L/h 规格:400×220×850
卫泉RO商用系列产品及说明
WQ-RO600G
基本配置: 1)自动冲洗 2)外置11G压力桶 3)适合300人左右饮水 使用。
基本配置: 七道九级
1)高品质精滤PP棉 2)纯正椰壳活性炭 3)KDF复合装置 4)离子交换装置 5)纳米级能量球 6)矿化球 7)纳米银布 8)UF超滤装置 适用于:家庭厨房用水
规格参数:
出水量:200L/h 规格:400×200×480 1箱4台
卫泉活化直饮系列产品及说明
WQ-970C基本配置: 七道九级来自卫泉RO商用系列产品及说明
WQ-RO100G
基本配置:
1)自动冲洗 2)外置11G压力桶 3)适合50人左右饮水
规格参数:
出水量:15.8L/h 规格:400×220×850
卫泉RO商用系列产品及说明
WQ-RO150G 基本配置: 1)自动冲洗 2)外置11G压力桶 3)适合100人左右饮水
规格参数: 出水量:23L/h 规格:400×220×850
WQ-1500
卫泉中央机系列产品及说明
中空纤维超滤膜产品技术手册英文
中空纤维超滤膜产品技术手册英文Hollow Fiber Ultrafiltration Membrane Product Technical Manual1. IntroductionHollow fiber ultrafiltration membranes are advanced filtration solutions widely used in various industries for liquid separation processes. This technical manual aims to provide a comprehensive guide to understanding the technology behind hollow fiber ultrafiltration membranes and their applications.2. Technology Overview2.1 Membrane StructureHollow fiber ultrafiltration membranes consist of a porous membrane material in a tube-like shape. The membrane material allows only the passage of particles within a specific size range, retaining larger particles and molecules while allowing smaller ones to pass through.2.2 Membrane Pore SizeThe pore size of the hollow fiber ultrafiltration membranes ranges from 0.01 to 0.1 micrometers, enabling the separation of macromolecules, suspended solids, colloids, and microorganisms from liquids.2.3 Membrane MaterialHollow fiber ultrafiltration membranes are typically made from polymer materials such as polysulfone, polyethersulfone, or polyvinylidene fluoride(PVDF). These materials offer excellent durability, chemical resistance, and high permeability.3. Advantages of Hollow Fiber Ultrafiltration Membranes3.1 High Filtration EfficiencyThe uniform and dense membrane structure of hollow fiber ultrafiltration membranes ensures efficient separation and filtration performance, achieving a high level of purity in the filtrate.3.2 Wide Range of ApplicationsHollow fiber ultrafiltration membranes are used in various industries, including water treatment, pharmaceuticals, food and beverage, biotechnology, and wastewater treatment. They are suitable for the recovery of valuable components, removal of pollutants, and purification of liquids.3.3 Cost-EffectivenessThe modular design of hollow fiber ultrafiltration membrane systems allows easy scale-up and flexibility. The compact size and high productivity of these systems result in reduced operational and maintenance costs.4. Applications4.1 Water TreatmentHollow fiber ultrafiltration membranes are widely applied in the treatment of surface water, groundwater, and wastewater. They effectively remove suspended solids, turbidity, bacteria, and viruses, ensuring safe and clean drinking water.4.2 Food and Beverage ProcessingIn the food and beverage industry, hollow fiber ultrafiltration membranes are utilized for clarification, concentration, and separation processes. They remove undesirable particles, improve product quality, and extend shelf life.4.3 Biotechnology and PharmaceuticalsHollow fiber ultrafiltration membranes are essential in biotechnology and pharmaceutical industries for the purification and concentration of bioactive substances, separation of proteins, and removal of endotoxins and viruses.4.4 Industrial ProcessesIndustrial processes such as recovery of valuable compounds, solvent exchange, and purification of chemicals can benefit from the use of hollow fiber ultrafiltration membranes. These membranes provide high selectivity, efficiency, and cost savings.5. Maintenance and TroubleshootingProper maintenance is crucial for ensuring the long-term performance and longevity of hollow fiber ultrafiltration membranes. Regular cleaning, monitoring, and periodic integrity testing are recommended practices. In case of any issues, refer to the manufacturer's guidelines or seek technical support.6. ConclusionThis technical manual provides a comprehensive overview of hollow fiber ultrafiltration membranes, their applications, advantages, andmaintenance requirements. By understanding the technology behind these membranes, users can effectively utilize them for various liquid separation processes in different industries.Note: This article has been written in the format of a technical manual, as requested.。
格拜卢普公司316不锈钢浸湿泵数据手册说明书
A GORMAN-RUPP COMPANY316 Stainless Steel Submersible Pumps⏹Flows from 300 to 5,200 GPM⏹Heads to 1,400 FT⏹Horsepowers: 10 to 500 HP⏹6” – 12” motor brackets, 2 and 4 pole⏹Temperatures to 158° F (70° C)EX Series8” – 16” Curves andTechnical Manual50010001500U.S. GALLONS PER MINUTEHeadtoFeetComposite Performance CurveA GORMAN-RUPP COMPANYEX Series 8” – 16” Curves and Technical ManualA GORMAN-RUPP COMPANY| Identificación bombaMinimum well diameter in inchesDiámetro interior mínimo del pozo en pulgadasPump type (mixed-flow) Bomba tipo (semiaxial)Stainless steel executionFabricación inoxidableHydraulic size Dimensión hidráulicaNumber of stages Número de etapas Impeller size Tamaño rodetesMotor external diameter in inches Diámetro exterior de motor en pulgadasNominal power in HP Potencia nominal en CVFrequency 60Hz Frecuencia de 60HzList of parts and materials | Detalle partes y materialesCampos de utilización8EXMax. water temperatureTemperatura máx. agua bombeada2A GORMAN-RUPP COMPANY8EX1Performances at 60Hz, 2 poles | Prestaciones a 60Hz, 2 polos60HzSubmersible PumpsQ=H e a d - A l t u r aH =A GORMAN-RUPP COMPANYPerformances at 60Hz, 2 poles | Prestaciones a 60Hz, 2 polos60Hz8EX2Submersible Pumps4A GORMAN-RUPP COMPANYPerformances at 60Hz, 2 poles | Prestaciones a 60Hz, 2 polos60HzQ=H e a d - A l t u r aH =8EX3Submersible PumpsA GORMAN-RUPP COMPANYPerformances at 60Hz, 2 poles | Prestaciones a 60Hz, 2 polos60HzQ=H e a d - A l t u r aH =8EX4Submersible PumpsA GORMAN-RUPP COMPANY| Identificación bombaMinimum well diameter in inchesDiámetro interior mínimo del pozo en pulgadasPump type (mixed-flow)Bomba tipo (semiaxial)Stainless steel executionFabricación inoxidable. max. capacityCaudal máxima al B.E.P.Number of stagesNúmero de etapasImpeller sizeTamaño rodetesMotor external diameter in inchesDiámetro exterior de motor en pulgadasNominal power in HPPotencia nominal en CVFrequency 60HzFrecuencia de 60HzCampos de utilizaciónMax. water temperatureTemperatura máx. agua bombeada8EX-110-8EX-1406A GORMAN-RUPP COMPANY7Performances at 60Hz, 2 poles | Prestaciones a 60Hz, 2 polos60HzQ=H e a d - A l t u r aH =8EX-110Submersible Pumps8A GORMAN-RUPP COMPANYPerformances at 60Hz, 2 poles | Prestaciones a 60Hz, 2 polos60HzQ=H e a d - A l t u r aH =Submersible Pumps8EX-140A GORMAN-RUPP COMPANY9| Identificación bombaMinimum well diameter in inches Diámetro interior mínimo del pozo en pulgadasPump type (mixed-flow)Bomba tipo (semiaxial)Stainless steel executionFabricación inoxidableHydraulic size Dimensión hidráulicaNumber of stages Número de etapas Impeller size Tamaño rodetesMotor external diameter in inches Diámetro exterior de motor en pulgadasNominal power in HP Potencia nominal en CVFrequency 60Hz Frecuencia de 60HzList of parts and materials | Detalle partes y materialesCampos de utilización10EXMax. water temperature Temperatura máx. agua bombeada10A GORMAN-RUPP COMPANYPerformances at 60Hz, 2 poles | Prestaciones a 60Hz, 2 polos60HzEff %m H mQ=Capacity CaudalH e a d - A l t u r aH =H ftSubmersible Pumps10EX1Pump supplied with NPTF companion flange, boltsand gasketLa bomba se suministra con contrabrida, pernos y juntaA GORMAN-RUPP COMPANYPerformances at 60Hz, 2 poles | Prestaciones a 60Hz, 2 polos60HzQ=H e a d - A l t u r aH =Submersible Pumps10EX212A GORMAN-RUPP COMPANYPerformances at 60Hz, 2 poles | Prestaciones a 60Hz, 2 polos60HzQ=H e a d - A l t u r aH =Submersible Pumps10EX3A GORMAN-RUPP COMPANY| Identificación bombaMinimum well diameter in inchesDiámetro interior mínimo del pozo en pulgadasPump type (mixed-flow) Bomba tipo (semiaxial)Stainless steel executionFabricación inoxidable . max. capacity Caudal máxima al B.E.P .Number of stages Número de etapas Impeller size Tamaño rodetesMotor external diameter in inches Diámetro exterior de motor en pulgadasNominal power in HP Potencia nominal en CVFrequency 60Hz Frecuencia de 60HzCampos de utilizaciónMax. water temperatureTemperatura máx. agua bombeada10EX-30014A GORMAN-RUPP COMPANYPerformances at 60Hz, 2 poles | Prestaciones a 60Hz, 2 polos60HzQ=H e a d - A l t u r aH =10EX-300Submersible PumpsA GORMAN-RUPP COMPANYPerformance range | Campos de utilización 12”12EX16A GORMAN-RUPP COMPANYPerformances at 60Hz, 2 poles | Prestaciones a 60Hz, 2 polos60HzQ=H e a d - A l t u r aH =12EX3Submersible PumpsA GORMAN-RUPP COMPANYPerformances at 60Hz, 2 poles | Prestaciones a 60Hz, 2 polos60HzQ=H e a d - A l t u r aH =12EX4Submersible Pumps18A GORMAN-RUPP COMPANY14”Performance range | Campos de utilización14EXA GORMAN-RUPP COMPANYPerformances at 60Hz, 2 poles | Prestaciones a 60Hz, 2 polos60HzQ=H e a d - A l t u r aH =14EX-650Submersible Pumps20A GORMAN-RUPP COMPANY16”Performance range | Campos de utilización16EXPerformances at 50Hz, 2 poles | Prestaciones a 50Hz, 2 polos50HzQ=H e a d - A l t u r aH =16EX-1000Submersible PumpsA GORMAN-RUPP COMPANYARIZONA (Main Office)7706 N. 71st Ave., Glendale, AZ 85303-1703 (623) 979-3560 • Fax (623) 979-2177 (800) 966-5240FLORIDA195 E. 3rd Street, Zolfo Springs, FL 33890(863) 735-8222 • Fax (863) 735-8202(800) 994-3045MISSISSIPPI11176 Green Valley Dr., Olive Branch, MS 38654(662) 895-1110 • Fax (662) 895-5083(866) 668-4914A GORMAN-RUPP COMPANYProud member of American Petroleum Institute and these organizations:Creating Quality Pump Systems and Satisfied Customers。
《EcoTech Toilet Wipes安全用料单》说明书
as amended by EC 453/2010Product: Toilet WipesVersion: Version 3Date: 28/04/2015 Supersedes: Version 2: dated 01/01/2015 Page: 1 of 11SECTION 1: IDENTIFICATION OF THE SUBST ANCE / PREPARATION AND OF THE COMPANY / UNDERTAKING1.1 Product identifier Toilet WipesOther means of identification ETTS1001.2 Relevant identified uses of the substance or mixture and uses advised againstUses: A wet wipe with biocidal activity for cleaning and disinfecting surfaces etc.Effective against MRSA, C-Diff & H1N1.Not to be used for:1.3 Details of the supplier of the Safety Data SheetCompany Name: EcoTech (Europe) LimitedAddress: EcoTech HouseFalkland CloseCharter Avenue Industrial EstateCoventryWest MidlandsCV4 8AUUnited KingdomTelephone: +44 (0)24 7647 1894Fax: +44 (0)24 7647 4743E-mail:Web Site www.ecotec 1.4 Emergency telephonenumberTelephone: National Poisons Information Service (UK) +44 (0)844 8920111 SECTION 2: HAZARDS IDENTIFICATION2.1 Classification of the substance or mixture- 67/548/EECMain hazards.as amended by EC 453/2010Product: Toilet WipesVersion: Version 3Date: 28/04/2015 Supersedes: Version 2: dated 01/01/2015 Page: 2 of 11- EC 1272/2008 Skin Irrit. 2: H315; Eye Irrit. 2: H319; Skin Sens. 1: H317:2.2 Label elementsSignal Word WarningHazard StatementEye Irrit. 2: H319 - Causes serious eye irritation.Skin Sens. 1: H317 - May cause an allergic skin reaction.Precautionary Statement: Prevention P102 - Keep out of reach of children. P103 - Read label before use.Precautionary Statement:ResponseP101 - If medical advice is needed, have product container or label at hand.P301+P312 - IF SWALLOWED: Call a POISON CENTER or doctor / physician ifyou feel unwell.P305+P351+P338 - IF IN EYES: Rinse cautiously with water for several minutes.Remove contact lenses, if present and easy to do. Continue rinsing.P321 - Specific treatment (see on this label).P332+P313 - If skin irritation occurs: Get medical advice/attention.P337+P313 - If eye irritation persists: Get medical advice/attention.2.3 Other hazards This product does not contain any PBT or VPvB substances.SECTION 3: COMPOSITION / INFORMATION ON INGREDIENTS3.1 Substances67/548/EEC / 1999/45/ECChemical Name Index No.CAS No.EC No.REACHRegistration Conc.(%w/w)Classificationas amended by EC 453/2010Product: Toilet WipesVersion: Version 3Date: 28/04/2015 Supersedes: Version 2: dated 01/01/2015 Page: 3 of 11Quaternary ammonium compounds, C12-14-alkyl[(ethylphenyl)meth yl]dimethyl, chlorides 85409-23-0 287-090-7 0 – 0.5% C; R34 Xn; R22N; R50Quaternary ammonium compounds, benzyl-C12-18-alkyldimethyl, chlorides 68391-01-5 269-919-4 0 – 0.5% C; R34 Xn; R22N; R50D-Limonene 601-029-00-7 5989-27-5 227-813-5 0 – 0.05% R10 Xi; R38R43 N; R50/533,7-dimethylocta-2,6-dienal (Citral)5392-40-5 226-394-6 0 – 0.05% Xi ; R38-R433,7-dimethyloct-6-en- 1-ol (Citronellol) 106-22-9 203-375-0 0 – 0.01% Xi-N ; R38-R43-R51/53linalool 78-70-6 201-134-4 0 – 0.001% H315, H3193,7-Dimethylocta-2,6-dien-1-ol (Geraniol) 106-24-1 203-377-1 0 – 0.001% H315, H317,H318EC 1272/2008Chemical Name Index No.CAS No.EC No.REACHRegistrationNumber Conc.(%w/w)ClassificationQuaternary ammonium compounds, C12-14-alkyl[(ethylphenyl)meth yl]dimethyl, chlorides 85409-23-0 287-090-7 0 – 0.5% Acute Tox. 4:H302; SkinCorr. 1B: H314;Aquatic Acute1: H400;Aquatic Chronic1: H410;Quaternary ammonium compounds, benzyl-C12-18-alkyldimethyl, chlorides 68391-01-5 269-919-4 0 – 0.5% Acute Tox. 4:H302; SkinCorr. 1B: H314;Aquatic Acute1: H400;Aquatic Chronic1: H410;D-Limonene 601-029-00-7 5989-27-5 227-813-5 0 – 0.05% Flam. Liq. 3:H226; Skin Irrit.2: H315; SkinSens. 1: H317;as amended by EC 453/2010Product: Toilet WipesVersion: Version 3Date: 28/04/2015 Supersedes: Version 2: dated 01/01/2015 Page: 4 of 11Aquatic Acute 1: H400;Aquatic Chronic 1: H410; 3,7-dimethylocta-2,6-dienal (Citral) 5392-40-5 226-394-6 0 – 0.05% SCI 2-SS1;H315, H317, H411 3,7-dimethyloct-6-en-1-ol (Citronellol) 106-22-9 203-375-0 0 – 0.01% SCI 2-SS 1;H315 H317 linalool78-70-6 201-134-4 0 – 0.001% H315, H319 3,7-Dimethylocta-2,6-dien-1-ol (Geraniol) 106-24-1 203-377-1 0 – 0.001% H315, H317, H3183.2 Mixtures See section 3.1 for further information.Further information For full text of H-statements and R-phrases: see SECTION 16.SECTION 4: FIRST AID MEASURES4.1 Description of first aid measures Inhalation Inhalation is highly unlikely due to liquid impregnated on a fabric substrate.Considered to be not hazardous by inhalation. Seek medical attention if irritation or symptoms persist.Eye contact Eye contact is unlikely due to liquid impregnated on a fabric substrate. IF INEYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention.Skin contact Seek medical attention ifirritation or symptoms persist.Ingestion Ingestion is highly unlikely due to liquid impregnated on a fabric substrate. Rinsemouth thoroughly. DO NOT INDUCE VOMITING. Seek medical attention if irritation or symptoms persist.4.2 Most important symptoms and effects, both acute and delayed Inhalation No specific symptoms noted. Eye contact May c ause eye irritation.as amended by EC 453/2010Product: Toilet WipesVersion: Version 3Date: 28/04/2015 Supersedes: Version 2: dated 01/01/2015 Page: 5 of 11Skin contact May cause allergic reactions in susceptible people.Repeated exposure may cause skin dryness or cracking.Ingestion No specific symptoms noted.4.3 Indication of any immediatemedical attention andspecial treatment needed If you feel unwell, seek medical advice (show the label where possible). No specific first aid measures noted.SECTION 5: FIREFIGHTING MEASURES5.1 Extinguishing media This product is not flammable. Use extinguishing media appropriate to thesurrounding fire conditions.5.2 Special hazards arising fromthe substance or mixture In the event of a large fire toxic fumes containing oxides of carbon may be formed, which would necessitate the use of a self-contained breathing apparatus.5.3 Advice for firefighters Standard protective equipment should be worn by fire fighters, in particular eye / faceprotection.SECTION 6: ACCIDENTAL RELEASE MEASURES6.1 Personal precautions,protective equipment andemergency procedures Avoid contact of the impregnating fluid with the eyes.6.2 Environmental precautions Large spillages are highly unlikely due to liquid impregnated on a fabric substrate.Advise local authorities if large spills cannot be contained. Do not allow product toenter drains. Do not flush into surface water. Prevent further spillage if safe.6.3 Methods and material forcontainment and cleaning up Large spillages are highly unlikely due to liquid impregnated on a fabric substrate Absorb with inert, absorbent material. Transfer to suitable, labelled containers for disposal. Clean spillage area thoroughly with plenty of water.6.4 Reference to other sections For recommended personal protective equipment see Section 8. For disposal seeSection 13.SECTION 7: HANDELING AND STORAGE7.1 Precautions for safehandling Avoid contact with eyes.Adopt best Manual Handlingconsiderations when handling, carrying and dispensing.as amended by EC 453/2010Product: Toilet WipesVersion: Version 3Date: 28/04/2015 Supersedes: Version 2: dated 01/01/2015 Page: 6 of 117.2 Conditions for safe storage,including anyincompatibilities Keep out of the reach of children. Keep in a cool, dry, well ventilated area. Keep containers tightly closed. Store in correctly labelled containers. Do NOT allow to freeze.7.3 Specific end use No relevant information availableSECTION 8: EXPOSURE CONTROLS / PERSONAL PROTECTION8.1 Control parameters The product is impregnated onto a fabric substrate so free liquid will not be availableand exposure significantly mitigated.8.1.1 Exposure Limit Values-8.2 Exposure controls8.2.1 Appropriate engineeringControlsKeep in a cool, dry, well ventilated area.8.2.2 Individual protectionmeasuresNone8.2.3 Environmentalexposure controls Do not empty into drains. Do not flush into surface water. Prevent further spillage if safe.8.2.3. Further information Information valid at the time of review of safety data sheet.SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES9.1 Information on basic physical and chemical propertiesa Appearance: White nonwoven fabric impregnated with a colourless solution.b Odour: Characteristic Lemon odour.c Odour threshold: Not available.as amended by EC 453/2010Product: Toilet WipesVersion: Version 3Date: 28/04/2015 Supersedes: Version 2: dated 01/01/2015 Page: 7 of 11d pH: 6.0 – 7.0e Melting point / freezing point: Not available.Not available.f Initial boiling point andboiling range:g Flash point: Not determined.h Evaporation rate: Not available.i Flammability (solid, gas): Not applicable.j Upper / lower flammability orNot available.explosive limits:k Vapour pressure: Not available.l Vapour density: Not available.m Relative density: 0.99 – 1.00n Solubility(ies): Impregnating fluid immiscible with water.Completely immiscible with water.o Partition coefficient: n-octanol/ water:p Auto-ignition temperature: Not available.q Decomposition temperature: Not available.r Viscosity: Water thin.s Explosive properties: Not available.t Oxidising properties: Not available.9.2 Other information None available.SECTION 10: STABILITY AND REACTIVITY10.1 Reactivity This preparation is stable under normal conditions of storage / use and no chemicalincompatibility is known.10.2 Chemical Stability Stable under recommended storage and handling conditions. The product is notflammable.as amended by EC 453/2010Product: Toilet WipesVersion: Version 3Date: 28/04/2015 Supersedes: Version 2: dated 01/01/2015 Page: 8 of 1110.3 Possibility of hazardousreactionsStrong acids and Strong bases. Strong oxidising agents.10.4 Conditions to avoid Avoid excessive heat. Do Not allow to freeze.10.5 Incompatible materials Strong acids and Strong bases. Strong oxidising agents.10.6 Hazardous decompositionproducts Combustion of the product will generate toxic fumes containing oxides of carbon may be formed.SECTION 11: TOXICOLOGICAL INFORMATION11.1 Information on toxicological effectsAcute toxicity Based on available data the classification criteria are not met.Skin corrosion / irritation May c ause skin irritation..Serious eye damage / irritation May c ause eye irritation.Respiratory or skinsensitisationMay cause allergic reactions in susceptible people.Germ cell mutagenicity No mutagenic effects reported.Carcinogenicity No carcinogenic effects reported.Reproductive toxicity No teratogenic effects reported.STOT-single exposure Not classified as a specific target organ toxicant after a single exposure.STOT-repeated exposure Not classified as a specific target organ toxicant after repeated exposure.Aspiration hazard Based on available data the classification criteria are not met.11.1.4 Toxicological InformationQuaternary ammoniumcompounds, benzyl-C12-18-alkyldimethyl, chloridesOral Rat LD50: 301 - 2000 mg/kgQuaternary ammoniumcompounds, C12-14-alkyl[(ethylphenyl)methyl]dimethyl, chloridesOral Rat LD50: 301 - 2000 mg/kgas amended by EC 453/2010Product: Toilet WipesVersion: Version 3Date: 28/04/2015 Supersedes: Version 2: dated 01/01/2015 Page: 9 of 11SECTION 12: ECOLOGICAL INFORMATION12.1 ToxicityQuaternary ammoniumcompounds, benzyl-C12-18-alkyldimethyl, chloridesDaphnia EC50/48h: 0.016 mg/lQuaternary ammoniumcompounds, C12-14-alkyl[(ethylphenyl)methyl]dimethyl, chloridesDaphnia EC50/48h: 0.016 mg/lD-Limonene Daphnia EC50/48h: 0.400000 mg/l Algae IC50/72h: 4.000000 mg/lFathead minnows LC50/96h: 0.71 mg/l12.2 Persistence anddegradability The surfactant(s) contained in this preparation complies (comply) with the biodegradability criteria as laid down in the Regulation (EC) No. 648/2004 on detergents. Data to support this assertion are held at the disposal of the competent authorities of the Member States and will be made available to them, at their direct request or at the request of a detergent manufacturer.12.3 Bio accumulative potential No data available.12.4 Mobility in soil No data available.12.5 Results of P BT and vPvBassessmentThe product does not contain any PBT or vPvB substances.12.6 Other adverse effects Not known.SECTION 13: DISPOSAL CONSIDERATION13.1 Waste treatment methods Contact a licensed waste disposal company. Dispose of as special waste incompliance with local and national regulations. For disposal within the EC, theappropriate code according to the European Waste Catalogue (EWC) should beused. Empty containers can be sent to landfill after cleaning, if in compliance withlocal and national regulations.SECTION 14: TRANSPORT INFORMATION14.1 UN number -14.2 UN proper shipping name -14.3 Transport hazard class(es) This preparation is not classified as “Hazardous” for transport purposes.as amended by EC 453/2010Product: Toilet WipesVersion: Version 3Date: 28/04/2015 Supersedes: Version 2: dated 01/01/2015 Page: 10 of 1114.4 Packing group14.5 Environmental hazards14.6 Special precautions for user Not applicable.14.7 Transport in bulk accordingto Annex II of MARPOL 73/ 78 and the IBC CodeNot applicable.SECTION 15: REGULATORY INFORMATION15.1 Safety, health andenvironmental regulations /legislation specific for thesubstance or mixture Commission Directive 2000/39/EC of 8 June 2000 established a first list of indicative occupational exposure limit values in implementation of Council Directive 98/24/EC on the protection of the health and safety of workers from the risks related to chemical agents at work. Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006 concerning the Regulation, Evaluation, Authorisation and Restriction of Chemicals (REACH), establishing a European Chemicals Agency, amending Directive 1999/45/EC and repealing Council Regulation (EEC) No 793/93 and Commission Regulation (EC) No. 1488/94 as well as Council Directive 76/769/EEC and Commission Directives 91/155/EEC, 93/67/EEC, 93/105/EC and 2000/21/EC, including amendments. Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006 with amendments. Commission Directive 91/322/EEC of 29 May 1991 on establishing indicative limit values by implementing Council Directive 80/1107/EEC on the protection of workers from the risks related to exposure to chemical, physical and biological agents at work.15.2 Chemical safety assessment No assessment has been carried out. SECTION 16: OTHER INFORMATIONR34 Causes burnsHarmful if swallowedSAFETY DATA SHEETIn accordance with REACH Regulation EC No. 1907/2006as amended by EC 453/2010Product: Toilet WipesVersion: Version 3Date: 28/04/2015 Supersedes: Version 2: dated 01/01/2015 Page: 11 of 11Text of risk phrases in Section 3 R10 - FlammableR22 - Harmful if swallowedR24 - Causes burnsR38 - Irritating to skin.R41 - Risk of serious damage to eyesR43 - May cause sensitisation by skin contact.R50 - Very toxic to aquatic organismsR50/53 - Very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment.R51/53 - Toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environmentText of Hazard Statements in Section 3 Flam. Liq. 3: H226 - Flammable liquid and vapour.Acute Tox. 4: H302 - Harmful if swallowed.Skin Corr. 1B: H314 - Causes severe skin burns and eye damage.Skin Irrit. 2: H315 - Causes skin irritation.H318: Causes serious eye damageSkin Sens. 1: H317 - May cause an allergic skin reaction.H319: Causes serious eye irritationAquatic Acute 1: H400 - Very toxic to aquatic life.Aquatic Chronic 1: H410 - Very toxic to aquatic life with long lasting effects. Aquatic Chronic 2: H411 - Toxic to aquatic life with long lasting effectsGlossary ADR European Agreement concerning the International Carriage of DangerousGoods by RoadIATA International Air Transport AssociationIMDG International Maritime Dangerous GoodsPBT Persistent, bio accumulative, toxicRID Convention concerning International Carriage by RailvPvB very persistent, very bio accumulativeSTOT Specific Target Organ ToxicityWEL Workplace Exposure Limit.General Information No relevant information availableFurther Information The information supplied in this Safety Data Sheet is designed only as guidance forthe safe use, storage and handling of the product. This information is correct to thebest of our knowledge and belief at the date of publication however no guarantee ismade to its accuracy, reliability or completeness. This information relates only tothe specific material designated and may not be valid for such material used incombination with any other materials or in any other process. It is the user'sresponsibility to satisfy him/herself as to the suitability of such information for his /her own particular use.。
Liquid Filter Containing 100% Isopropyl Alcohol 产品
化学品安全技术说明书物品名称: Liquid Filter Containing 100% Isopropyl Alcohol; 含100%异丙醇的液体过滤器修正日期: 2022-07-01符合GB/T 16483和GB/T 17519标准SDS ID: 0248 (CHINA)版本 1.1物品名称Liquid Filter Containing 100% Isopropyl Alcohol; 含100%异丙醇的液体过滤器 产品说明产品充满100%异丙醇,在运输过程中加盖并装袋密封。
过滤器本身被认为是一个物品。
供应商的详细情况当地信息 (Local information):艾微美科材国际贸易(上海)有限公司 ATMI International Trading Co,LTD上海市科苑路88号德国中心二号楼523-533室Unit 523-533, Tower 2, German Center, No.88 Keyuan Road, Shanghai 201203, China邮政编码: 201203 Zip Code: 201203电话:86-21-80236500 Telephone: 86-21-80236500应急电话: Emergency Call:86-532-83889090 (中国24小时化学事故应急咨询服务热线) 4001-204937 (ChemTrec 中国)1-703-527-3887 (ChemTrec 国际) 86-21-80236500 (上海)电子邮箱:********************************产品用途在设备级别使用,用于关键清洁程序的单晶圆喷雾过程时,除去异丙醇中的金属和颗粒。
使用限制不明。
GHS 易燃液体 - 类别 2急性毒性 - 经口 - 类别 4物品名称: Liquid Filter Containing 100% Isopropyl Alcohol; 含100%异丙醇的液体过滤器修正日期: 2022-07-01急性毒性 - 经皮 - 类别 5严重眼损伤/眼刺激 - 类别 2A特异性靶器官毒性 — 一次接触 - 类别 3 ( 中枢神经系统 ) 标签要素 象形图信号词 危险危险性说明高度易燃液体和蒸气。
表面活性剂专业缩写词及国内代号
净洗剂AN脂肪醇聚氧乙烯醚
匀染剂AN脂肪胺聚氧乙烯醚(尼凡丁)
AOS α-烯基磺酸盐
AP烷基磷酸酯
APE千基酚聚氧乙烯醚
APG烷基多糖苷
AR617精炼剂油酸钠、碳酸钠和三聚磷酸钠为主的混合物
AS脂肪醇硫酸钠
AS-33含33%脂肪醇硫酸钠的水溶液
ASEA烷基硫酸酯单乙醇胺盐
ASTM美国标准试验方法
AV酸值
十二烷基二甲基甜菜碱.BS-12
十六烷基三甲基溴化铵(1631)
[供应]十二烷基三甲基氯化铵(1231)
[供应]十八烷基三甲基氯化铵(1831)
[供应]十六/十八烷基二甲基叔胺
可伯拉瓦纳公司产品说明:动力化学应用限定版洁净厕所洗涤剂说明书
7. Handling and Storage
Precautions for Safe Handling: Do not use on any surface that can be damaged by acid materials. Do not breathe mist/vapors. Wash hands, face and any skin contact thoroughly after handling. Do not eat, drink or smoke when using this product. Wear protective gloves, protective clothing, eye protection, face protection. Use product only according to label directions. If unsure about safe use, contact your supervisor. Conditions for Safe Storage: Keep out of reach of children. Do not contaminate water, food or feed by storage and disposal. Store locked up in tightly closed, original, corrosive resistant container in a cool (10Û-Û& -vGenUtil\ated areZa. HOO Incompatibility: Chlorine bleach, alkali.
Label Elements:
Symbol:
Signal word:
高速纤维束过滤器技术规格书
金牛化工40万吨/年PVC工程公用工程部份循环水场高效纤维过滤器技术规格书天津辰鑫石化工程设计有限公司目录1 总则 (1)2 设备运行环境条件 (1)3 设备名称及数量 (3)4 设备名称及技术规范 (3)5 设备参数表 (4)6 高效纤维过滤器设备供货范围 (5)7 制造标准及规范 (6)8 卖方提供设计资料要求 (7)1 总则本技术规格书用于金牛化工40万吨/年PVC工程公用工程部份循环水场高效纤维过滤器。
它包括该设备的功能设计、结构、性能、安装和实验等方面的技术要求。
本技术规格书提出的是最低限度的技术要求,并未对一切技术要求做出详细的规定,也未充分引述有关标准及规范的条文。
卖方应提供符合本技术规格书和相关的国际、国内工业标准的优质产品和相应服务。
如卖方没有对本技术规格书提出书面异议,买方及买方代表则能够为卖方提供的产品完全知足本技术规格书的要求。
如卖方有除本规范之外的其他要求,应以书面形式提出,经供、需两边讨论确认后,附于本技术规格书。
本技术规格书所引用的标准若与卖方所执行的标准发生矛盾时,按较严格的标准执行。
并以此为依据进行验收。
如有异议,买方及买方代表按照情形进行决定。
卖方对高效纤维过滤器的成套系统设备的质量负有全责,包括分包(或外购)的产品,其分包(或外购)的产品制造商应事前征得买方及买方代表的确认。
在合同签定后,买方及买方代表有权因规范、标准、规程及外部条件发生转变而提出一些补充和修改要求,具体项目和内容由供、需两边协商肯定。
卖方应依照国标、部标、行标、买方代表的设计图纸和本技术规格书的要求进行设计制造、查验和实验。
2 设备运行环境条件安装地址沧州临港经济技术开发区东区40万吨/年PVC项目界区内。
气象资料2.2.1 气温年平均气温℃最热月(7月)平均气温℃最冷月(1月)平均气温 -8℃极端最高气温℃极端最低气温 -20℃2.2.2 湿度年平均相对湿度 %月平均最高相对湿度 85%月平均最低相对湿度 35% 2.2.3 大气压最高压力最低压力年平均压力月平均最高压力月平均最低压力2.2.4 降雨量年平均降雨量 643mm月最大降雨量时最大降雨量10分钟最大降雨量2.2.5 降雪量最大积雪厚度 300mm雪荷载 20kg/m2 2.2.6 风主导风向年: SW冬:(12月~2月) NW夏:(6月~8月) SW年平均风速 s刹时最大风速(地上10米) 29m/s平均风压(地上10米)40kg/m2 2.2.7 地质条件地震烈度 7度(麦里卡)冻土深度-350mm 其它房间采暖期 4个月雷暴天/年最大雷暴日数 24天 暴雨强度计算公式 I=)819.4(lg 099.8227.10671.0++t TE(mm/min ) 供电条件380V/220V ±5%,三相四线系统,中性点接地; 频率:50(+Hz 。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Type WBR 85 ºC, Industrial Grade, Axial Leaded, Aluminum85 ºC, Industrial GradeType WBR capacitors are the preferred choice for many varied industrial applications because they have high capacitance and extended life characteristics. The rugged construction delivers the high vibration resis-tance required in industrial applicationsHigh capacitance Extended lifeRugged construction High vibration resistance••••HighlightsSpecificationsCapacitance Range:Voltage Range:Capacitance Tolerance:Operating Temperature Range:Leakage Current: Ripple Current Multipliers: 1.0 to 5,000 µF16 to 450 Vdc16 to 50 Vdc -10 + 150%, 75 to 350 Vdc–10 + 100%, 450 Vdc –10 + 50%–40 ºC +85ºC16-75 Vdc ≤ 0.01CV + 10 µA150-450 Vdc ≤ 0.03CV + 20 µA45 ºC 55 ºC 65 ºC 75 ºC 85 ºC 95 ºC 105 ºC 1.50 1.46 1.321.171.000.790.50Ambient TemperatureFrequency 60 Hz 120 Hz 400 Hz 1000 Hz 10 kHz 50 kHz 100 kHz 0-60 Vdc 0.85 1.00 1.10 1.15 1.15 1.15 1.1561-200 Vdc 0.83 1.00 1.15 1.20 1.20 1.20 1.20201-450 Vdc0.801.001.151.301.301.301.30Load Life:Shelf Life:Vibration: 2,000 h @ +85 ºC∆ Capacitance ±20% ∆ ESR 150% of limit ∆ DCL 100% of limit500 h @ 85 ºC∆ Capacitance ±20% ∆ ESR 150% of limit ∆ DCL 100% of limit10 to 55 Hz; 0.06” and 10 g max, 2 h in each planeOutline DrawingComplies with the EU Directive 2002/95/EC requirement restricting the use of Lead (Pb), Mercury (Hg), Cadmium (Cd), Hexavalent chromium (Cr(VI)), PolyBrominated Biphenyls (PBB) and PolyBrominated Diphenyl Ethers (PBDE).元器件交易网Type WBR 85 ºC, Industrial Grade, Axial Leaded, AluminumPart Numbering SystemRatingsWBR 500—16A EType Capacitance Voltage Lead Epoxy Endseal WBR500 = 500 µF16 = 16 VdcA = 1.5" 20 AWG E = Epoxy Blank = See tableBlank = No epoxyRippleMax Case Catalog Max ESR @ 85 ºC Size Cap Part Number 120 Hz 120 HzD x L (µF)(Ω)(A)(Inches)16 Vdc ( 20 Vdc Surge )100WBR100-16A 5.300.0570.340.76250WBR250-16A 2.100.1180.340.88500WBR500-16A 1.100.2700.40 1.001000WBR1000-16A 0.530.4200.40 1.322000WBR2000-16A 0.270.6600.47 1.573000WBR3000-16A 0.180.8200.52 1.834000WBR4000-16A 0.13 1.0000.65 1.835000WBR5000-16A 0.11 1.2000.65 1.8325 Vdc ( 30 Vdc Surge )10WBR10-25A 48.000.0180.280.5725WBR25-25A 19.000.0310.280.5750WBR50-25A 9.500.0440.340.76100WBR100-25A 4.800.0740.340.76250WBR250-25A 1.800.1550.40 1.00500WBR500-25A 0.950.2800.40 1.321000WBR1000-25A 0.480.4500.47 1.572000WBR2000-25A 0.230.7200.65 1.8335 Vdc ( 40 Vdc Surge )100WBR100-35A 4.400.0860.400.88150WBR150-35A 2.950.1140.40 1.00300WBR300-35A 1.450.1950.47 1.32500WBR500-35A 0.870.2850.52 1.671000WBR1000-35A 0.440.4500.54 1.672000WBR2000-35A 0.220.9100.65 1.833000WBR3000-35A 0.15 1.1500.74 1.6950 Vdc ( 65 Vdc Surge )1WBR1-50A 390.000.0100.280.572WBR2-50A 195.000.0120.280.575WBR5-50A 77.000.0140.280.5710WBR10-50A 39.000.0200.280.5725WBR25-50A 15.500.0350.340.7650WBR50-50A 7.700.0600.40 1.88100WBR100-50A 3.900.1400.40 1.00150WBR150-50A 2.500.1600.40 1.00250WBR250-50A 1.500.2200.40 1.32500WBR500-50A 0.770.3400.52 1.571000WBR1000-50A 0.390.5300.65 1.831500WBR1500-50A 0.250.7400.65 1.8375 Vdc ( 95 Vdc Surge )150WBR150-75A 2.500.1800.47 1.32275WBR275-75A 1.300.2800.52 1.57500WBR500-75A 0.720.4000.651.83RippleMax Case Catalog Max ESR @ 85 ºC Size Cap Part Number120 Hz 120 Hz D x L (µF)(Ω)(A)(Inches)150 Vdc ( 175 Vdc Surge )4WBR4-150A 78.000.0180.340.88 5WBR5-150A 62.000.0200.340.88 8WBR8-150A 39.000.0300.400.88 10WBR10-150A 31.000.0340.400.88 16WBR16-150A 19.500.0450.40 1.00 20WBR20-150A 15.500.0500.40 1.32 30WBR30-150A 10.500.0850.40 1.57 40WBR40-150A 7.800.0960.47 1.32 50WBR50-150A 6.200.1050.47 1.57 60WBR60-150A 5.200.1300.65 1.57 80WBR80-150A 3.900.1550.65 1.83 100WBR100-150A 3.100.1900.65 1.83 150WBR150-150A2.050.2300.74 1.69180 Vdc ( 250 Vdc Surge )125WBR125-180A 2.300.3000.74 1.69 250 Vdc ( 300 Vdc Surge )4WBR4-250A 64.000.0350.40 1.008WBR8-250A 32.000.0560.40 1.32 12WBR12-250A 21.500.0620.40 1.32 16WBR16-250A 16.000.0650.47 1.57 20WBR20-250A 12.500.0750.47 1.57 30WBR30-250A 8.400.1050.52 1.57 40WBR40-250A 6.300.1250.52 1.83 50WBR50-250A 5.000.1400.65 1.83 60WBR60-250A 4.200.1800.65 1.83 80WBR80-250A3.100.2000.74 1.69 350 Vdc ( 400 Vdc Surge )4WBR4-350A 51.000.0360.40 1.00 8WBR8-350A 26.000.0500.47 1.32 20WBR20-350A 10.000.0900.52 1.57 40WBR40-350A 5.100.1350.65 1.83 450 Vdc ( 525 Vdc Surge )1WBR1-450A 205.000.0230.40 1.00 2WBR2-450A 102.000.0300.40 1.00 4WBR4-450A 51.000.0380.47 1.57 5WBR5-450A 40.000.0420.47 1.57 8WBR8-450A 26.000.0530.47 1.57 10WBR10-450A 20.000.0580.52 1.57 12WBR12-450A 17.000.0620.65 1.83 16WBR16-450A 12.500.0840.65 1.83 20WBR20-450A 10.000.1050.65 1.83 30WBR30-450A6.700.1300.741.69元器件交易网。