万立方米日城市污水处理厂设计污水处理设计说明

合集下载

推荐-12万立方米每天的城市污水处理厂工艺设计 精品

推荐-12万立方米每天的城市污水处理厂工艺设计 精品

课程设计说明书设计题目:120000m3/d的城市污水处理厂工艺设计学院:环境与生物工程学院专业:环境工程班级:设计者姓名:设计时间: 20XX.10 -20XX.11目录污水处理工程课程设计任务书一、课程设计的内容和深度污水处理课程设计的目的在于加深理解所学专业知识,培养运用所学专业知识的能力,在设计、计算、绘图方面等得到锻炼。

针对一座二级处理的城市污水处理厂,要求对主要污水处理构筑物的工艺尺寸进行设计计算,确定污水厂的平面布置和高程布置。

最后完成设计计算说明书和设计图(污水处理厂平面布置图和污水处理厂高程图)。

设计深度为初步设计的深度。

最大日处理量为12万立方米每天1、设计题目某城市污水处理厂12万m3/工艺计算2、基本资料(1)城市污水处理厂设计水量及水质:(2污水拟采用传统活性污泥法工艺处理,具体流程如下:污水→分流闸井→格栅间→污水泵房→出水井→计量槽→沉砂池→初沉池→曝气池→二沉池→消毒池→出水(3)气象与水文资料风向:多年主导风向为西南风;气温:年平均气温4.6℃;最热月平均为26.5℃;极端气温,最高为33℃,最低为-40℃,最大冻土深度为1.9米水文:降水量多年平均为639.9mm;蒸发量平均为1210mm,地下水位,地面下5-6米。

(4)厂区选型污水厂选址在185-192m之间,平均地面标高为187.5m。

平均地面坡度为0.3﹪-0.5﹪,地势为西北高,东南低。

厂区征地面积为东西长380米,南北长280米。

3、设计内容①对工艺构筑物选型作说明;②主要处理设施(格栅、沉砂池、初沉池、曝气池、二沉池)的工艺计算;③污水处理厂平面和高程布置图4、设计成果①设计计算说明书一份②设计图纸:污水厂平面图和污水厂处理高程图各一张1.水质水量及深度处理要求1.1进水水质进水水质的各个指标见表1-1表1-1 进水水质进水BOD5180mg/L,出水要求BOD520mg/L,去除率为(180-20)/180 100% =88.89%,其他的指标均和BOD5计算相同。

污水处理厂初步设计说明手册

污水处理厂初步设计说明手册

设计任务书一、设计项目某污水厂初步设计二、设计资料1.基本资料⑴设计流量:Q=30000+n×1000m3/d(n学号,1~30号)⑵污水水质:COD=380mg/L,BOD5=250mg/L,SS=200mg/LpH=6~9。

夏季水温25℃,冬季水温15℃,常年平均水温20℃。

⑶纳污河流:位于城市的东侧自南向北,20年一遇洪水水位标高,常水位标高。

⑷根据城市总体规划,污水厂拟建于该城市下游河流岸边,地势平坦,拟建处的地面标高。

该城市污水主干管终点(污水厂进水口)的管内底标高。

⑸气象资料:该地区全年主导风向为西南风。

地势平坦,地质情况良好,满足工程地质要求,平均气温13℃,冬季最低气温-12℃,最大冰冻深度,夏季最高气温37℃,年平均降雨量1010mm,蒸发量1524mm。

⑹处理要求:处理水水质满足:BOD5≤20mg/L;COD≤60mg/L;SS≤20mg/L。

处理后的污水纳入河流,对污泥进行稳定化处理、脱水后泥饼外运填埋或作农肥。

⑺其他资料:厂区附近无大片农田,各种建筑材料均能供应,电力供应充足。

三、设计内容:1、根据给定的原始资料,确定污水厂的规模和污水设计水量。

2、按照原始资料数据进行处理方案的确定,拟定处理工艺流程,选择污水、污泥的处理构筑物,并用方框图表示。

进行工艺流程中各处理单元的处理原理说明。

3、进行各构筑物的尺寸计算,各构筑物的设计参数应根据同类型污水的实际运行参数或参考有关手册选用。

4.设备选型计算。

5.平面和高程布置根据构筑物的尺寸,合理进行平面布置;高程布置应在完成各构筑物计算及平面布置草图后进行。

各处理构筑物应尽力采用重力流,各处理构筑物的水头损失可直接查相关资料,但各构筑物之间的连接管的水头损失则需计算确定。

6.编写设计说明书、计算书四、设计成果1.污水处理厂总平面布置图1张2.高程布置图1张3.设计说明书、计算书一份1.《水质工程学》教材2.《排水工程》下册,张自杰等主编,中国建筑工程出版社。

污水处理厂设计计算说明书

污水处理厂设计计算说明书

目录摘要 (1)Abstract (1)设计说明书1. 工程概况 (2)1.1. 自然条件 (2)1.2. 进厂污水 (3)1.3. 出水水质要求 (3)2. 主工艺比选 (3)2.1. 污水水质分析 (4)2.2. 可选工艺 (5)2.2.1. 传统A2/O工艺 (5)2.3. 主工艺确定 (5)3. 工艺流程设计说明 (6)3.1. 一级处理设计说明 (6)3.1.1. 中隔栅 (6)3.1.2. 细格栅 (6)3.1.3. 沉砂池 (7)3.1.4. 污水提升泵房 (7)3.3. 污泥处理系统设计说明 (8)3.3.1. 储泥、搅拌、提升 (8)3.3.2. 污泥浓缩脱水车间 (8)3.4. 加药系统设计说明 (9)3.4.1. 加药(碱度补充)系统 (9)4. 污水厂布置说明 (9)4.1. 整体布局 (10)4.2. 办公生活区 (10)4.3. 污水处理区、动力区 (10)4.4. 污泥区、加药区 (10)摘要本工程为城市污水处理厂工艺设计(7万m3/d),地处,日处理城市污水7万方。

进厂污水氮含量较高,磷含量正常,污水处理重在脱氮,兼顾除磷。

本工程采用不设初沉池的三沟不等体积A2O工艺,采用新型的8阶段同步脱氮除磷运行模式,较传统的6阶段模式强化了除磷功能,减小了边沟体积从而减少了厌氧释磷量,具有良好的脱氮除磷效果。

三沟交替运行,构筑物集中个数少,无需初沉池二沉池;抗冲击负荷能力强,出水水质稳定,污泥稳定无需消化。

本工程采用水下推流器和薄膜微孔曝气器组合的复合曝气模式,突破了氧化沟的深度限制,达到6m,提高了氧利用效率,节能省地。

污水经过中细格栅、沉砂池等一级处理和A2O二级处理后达到排放标准,直接排放或回用。

本工程处理效果好,能耗低,厂构筑物集约,自动化程度高,管理方便。

AbstractThis projiect is "Jinan wastewater treatment factory technological design (70000m3/d) ". This project locates at Jinan in Shanxi province . Entering factory sewage nitrogen content is higher, the phosphor content is normal, the wastewater treatment is heavy to be taking off nitrogen, gives attention to both in phosphor.This project adoption doesn't establish three ditches that the beginning sinks pond not to wait the physical volume A2O type to oxidize a ditch craft and adopt new of 8 stages synchronously take off nitrogen the phosphor circulates mode, besides which, more traditional of 6 stage modes enhanced in addition to phosphor function, let up the side ditch physical volume to reduce to be disgusted with oxygen to release amount of Lin thus, had to goodly take off nitrogen in addition to phosphor effect. the water fluid matter stabilizes, dirty mire's stabilizing don't need digest.This engineering adoption underwater pushes to flow a tiny bore Pu spirit machine of machine and thin film to combine of compound Pu spirit mode, broke the depth restriction of oxidizing the ditch, raised oxygen to make use of an efficiency, economize on energy ground in the province.Sewage through medium thin space grid, sink sand pond etc. an attain exhaustion standard after oxidizing the second class processing of ditch, directly emissions or time is used.This engineering handles effective, can consume low, construct a thing inside the factory intensive, automate degree Gao, manage convenience.设计计算说明书1.工程概况1.1.自然条件本工为“城市污水处理厂工艺设计”,工程所在地为地区,工程所在地的人口、自然、气象、地址条件如下:1、设计人口(近期)46万人。

污水处理厂设计说明书

污水处理厂设计说明书

贵州大学课程设计任务书课题名称污水处理工程学院土木工程学院专业给水排水工程班级 101学号 1008070030姓名程威污水处理工程课程设计任务书一、目的与任务1.目的本设计是污水处理工程教学中一个重要的实践环节,要求综合运用所学的有关知识,在设计中掌握解决实际工程问题的能力,并进一步巩固和提高理论知识。

2.任务根据已知资料,进行城市污水处理厂的工艺设计。

要求确定污水处理流程,计算各处理构筑物的尺寸,布置污水处理厂总平面图和高程图。

二、设计内容和要求1.设计说明书说明城市概况、设计任务、工程规模、水质水量、工艺流程、设计参数、主要构筑物的尺寸和个数、主要设备的型号和数量等;有关内容可参考如下所列。

第一章总论第一节设计任务和内容第二节基本资料第二章污水处理工艺流程说明污水处理工艺流程比较、论证(提出2种以上的工艺方案进行比较),污水处理工艺流程选定。

第三章污水处理构筑物设计按照选定的工艺流程,分节设计每个污水处理单元,简要论证比较,列出各构筑物的计算过程、主要设备(如水泵、鼓风机等)的选取。

第四章污泥处理构筑物的设计。

按照选定的污泥处理工艺流程,分节设计每个污泥处理单元,说明每个处理单元内的主要设备配置情况。

第五章污水厂总体布置第一节主要构(建)筑物与附属建筑物第二节污水厂平面布置第三节污水厂高程布置污水处理厂的高程计算(各构筑物内部的水头损失查阅教材或手册,构筑物之间的水头损失按管道长度计算)2设计图纸污水处理厂总平面布置图和高程布置图各一张,均为A2图幅的CAD 制图。

污水厂总平面图应按初步设计要求去完成,图上应绘出主要处理构筑物、处理建筑物、辅助构(建)筑物、附属建筑物、道路、绿化地带及厂区界限等,并用坐标表示其外形尺寸和相互距离,应有坐标轴线或坐标网格。

总平面图上绘出各种连接管渠,管道以单线条表示,并标明管径。

图中应附构(建)筑物一览表,说明各构(建)筑物的名称、数量及主要外形尺寸。

图中应附图例及必要的文字说明。

日处理量10万吨城市污水处理厂初步设计

日处理量10万吨城市污水处理厂初步设计

日处理量10万吨城市污水处理厂初步设计城市污水处理厂是一种重要的环保设施,用于处理城市中产生的大量污水。

在初步设计中,需要考虑到日处理量、污水处理工艺、设备选型以及配套设施等方面。

以下是一个大致的1200字以上的初步设计方案。

一、项目背景城市污水处理厂的建设是为了解决城市中大量产生的污水的处理问题。

经过初步测算,该城市的日处理量为10万吨,因此需要建设一座符合该规模的污水处理厂。

二、污水处理工艺根据日处理量为10万吨的需求,本设计方案选用了A2/O(缺氧-好氧-沉淀)工艺。

该工艺具有以下优点:1)占地面积小,适合中小型城市;2)处理效果好,能够达到国家排放标准;3)投资、运营成本较低。

三、工程布置1.总体布置:2.进水系统:设计选用人工攬并法进水,在进水口设置格栅除杂。

并设置一个小型污泥浓缩池,用于污泥的初步浓缩。

3.初沉池:初沉池设置在进水口之后,通过重力沉淀对污水进行预处理。

初沉池的出流口通过集水管将污水送入调节池。

4.调节池:调节池的作用是对来水进行平稳调节,控制进水水质的波动。

调节池设有多个反硝化区和缺氧区,通过不同的区域设置,使得进入A2/O系统的水质能够平稳保持。

5.A2/O处理系统:A2/O处理系统包括好氧区、缺氧区和曝气区,用于去除污水中的有机物、氨氮和无机磷。

系统选择了高效、节能的生物填料,用于增加曝气效果。

根据日处理量为10万吨的要求,设计了多个处理单元,确保系统的稳定运行。

6.沉淀池:A2/O系统出流的污水首先进入沉淀池进行沉淀处理。

沉淀池通过重力作用,将污水中的悬浮固体物质沉淀到池底,形成污泥。

7.除磷除氮系统:沉淀池出流的水进入除磷除氮系统,该系统采用生物除磷除氮的方法。

生物除磷除氮是一种高效、环保的脱氮脱磷工艺,能够有效去除污水中的氮、磷等有害物质。

8.出水系统:经过沉淀和除磷除氮处理后的污水达到了国家排放标准。

出水系统通过多级过滤和消毒,最后将处理后的水排入附近的河流或者进行再利用。

12万m3每天的城市污水处理厂工艺设计

12万m3每天的城市污水处理厂工艺设计

课程设计说明书设计题目:120000m3/d的城市污水处理厂工艺设计学院:环境与生物工程学院专业:环境工程班级:设计者姓名:设计时间: 2008.10 -2008.11目录1.水质水量及深度处理要求 (4)1.1进水水质 (4)1.2出水水质 (5)2.方案论证 (5)2.1方案确定依据 (5)2.1.1生化处理方案确定依据 (5)2.1.2污泥处理工艺路线确定依据 (6)2.2方案比较 (6)2.2.1生化处理方案比较 (6)2.2.2污泥处理方案比较 (8)2.3方案确定 (8)2.3.1生化处理方案确定 (8)2.3.2污泥处理方案的确定 (9)3.设计计算 (10)3.1水质平衡计算 (10)3.2主体构筑物设备计算 (10)3.2.1格栅设计计 (10)3.2.2沉砂池设计计算 (11)3.2.3初沉池设计计算 (11)3.2.4曝气池设计计算 (12)3.2.5曝气池辅助设备选择 (16)3.2.5二沉池设计计算 (19)3.3.6污泥处理过程的设计计算 (19)3.4设备选型 (23)3.4.1配水井前泵的选择 (23)3.4.2加药泵的选择 (23)4.设计结论 (26)4.1设计方案特点 (26)4.2工艺流程图 (26)4.3构筑物设备一览表 (27)结束语 (29)参考文献 (30)污水处理工程课程设计任务书一、课程设计的内容和深度污水处理课程设计的目的在于加深理解所学专业知识,培养运用所学专业知识的能力,在设计、计算、绘图方面等得到锻炼。

针对一座二级处理的城市污水处理厂,要求对主要污水处理构筑物的工艺尺寸进行设计计算,确定污水厂的平面布置和高程布置。

最后完成设计计算说明书和设计图(污水处理厂平面布置图和污水处理厂高程图)。

设计深度为初步设计的深度。

最大日处理量为12万立方米每天1、设计题目某城市污水处理厂12万m3/工艺计算2、基本资料(1)城市污水处理厂设计水量及水质:(2污水拟采用传统活性污泥法工艺处理,具体流程如下:污水→分流闸井→格栅间→污水泵房→出水井→计量槽→沉砂池→初沉池→曝气池→二沉池→消毒池→出水(3)气象与水文资料风向:多年主导风向为西南风;气温:年平均气温4.6℃;最热月平均为26.5℃;极端气温,最高为33℃,最低为-40℃,最大冻土深度为1.9米水文:降水量多年平均为639.9mm;蒸发量平均为1210mm,地下水位,地面下5-6米。

万吨天城市生活污水处理厂工艺毕业设计毕业设计说明书

万吨天城市生活污水处理厂工艺毕业设计毕业设计说明书

万吨天城市生活污水处理厂工艺毕业设计说明书1. 引言生活污水处理是现代城市建设中的重要环保工作之一。

随着城市化进程的不断加快,城市生活污水的排放量也不断增加,给环境带来严重污染和健康隐患。

本文档将对万吨天城市生活污水处理厂的工艺进行毕业设计说明,旨在设计出一个高效、经济、可持续的生活污水处理工艺方案。

2. 目标与要求设计一个万吨天城市生活污水处理厂的工艺,要求满足以下目标和要求:1.处理能力:按照设计要求,达到每天处理万吨的城市生活污水。

2.出水标准:出水达到国家、地方和环保部门规定的合格标准,保证排放水质稳定。

3.设备选型:选择适用于大规模城市生活污水处理厂的成熟、可靠的设备。

4.工艺效益:考虑投资、运行成本,力求经济、高效、节能的工艺方案。

5.后处理:设计适当的处理方案,对剩余污泥、氨氮、废气等进行处理。

3. 工艺选择与设计根据前期调研和分析,本设计方案的工艺选择如下:1.预处理:采用格栅除污器、砂沉池和调节池等工艺进行初步固液分离和调节水质。

2.活性污泥法:采用常温常压下的活性污泥法进行生物处理。

3.二沉池:采用二沉池对污水进行二次固液分离,将活性污泥与水体分离。

4.除磷除氮工艺:引入除磷和除氮工艺,提高出水水质达标率。

5.深度处理:通过混凝、沉淀和过滤等工艺进一步提高水质,确保出水水质稳定。

6.污泥处理:污泥采取浓缩、脱水、干化等处理手段,减少污泥体积,提高处理效率。

4. 设备选型与优化根据设计要求和选用工艺,对各个处理单元进行设备选型和优化。

主要设备包括:1.格栅除污器:选择适合处理大规模污水的自动化格栅除污器,提高初次固液分离效果。

2.活性污泥池:选择适宜的活性污泥曝气设备和搅拌器,保证微生物的正常生长。

3.二沉池:选用结构简单、操作稳定的二沉池设备,实现二次固液分离。

4.混凝剂添加系统:根据实际情况,选择合适的混凝剂添加系统,提高混凝效果。

5.过滤器:选用高效过滤器,去除微小颗粒物和胶体颗粒,提高水质处理效果。

某城市日处理水量3万3m污水处理厂工艺设计课程设计

某城市日处理水量3万3m污水处理厂工艺设计课程设计

第1章课程设计任务书1.1设计题目某城市日处理水量3万污水处理厂工艺设计1.2设计资料1.处理流量:5万2.进出水要求1.3设计要求1.方案确定按照原始资料数据进行处理方案的确定,拟定处理工艺流程,选择各处理构筑物。

2.设计计算各构筑物的设计参数应根据同类型污水的实际运行参数或参考有关手册选用;各构筑物的尺寸计算。

3.平面和高程布置根据构筑物的尺寸合理进行平面布置和高程布置。

4.编写设计说明,计算书第2章污水处理工艺流程说明2.1工艺方案分析工艺工艺自被开发以来,就因为某特有的经济技术化优势和环境效益,愈来愈受到人们的广泛重视。

在一个处理系统中同时具有厌氧区、缺氧区、和好氧区,能够同时做到脱氧、除磷和有机物的降解。

3m 3m /d 2A /O 2A /O污水经过第一个厌氧反应器以后进入缺氧反应器,本反应器的首要功能是进行脱氧。

硝态氮通过混合液内循环由好氧反应器传输过来,通常内回流为倍原污水流量,部分有机物在反硝化菌的作用下利用硝酸盐作为电子受体而得到降解去除。

混合液从缺氧反应区进入好氧反应区,混合液中的浓度已基本接近排放标准,在好氧反应区出进一步降解有机物外,主要进行氧氮的硝化和磷的吸收,混合液中硝态氮回流至缺氧反应区,污泥中华过量吸收的磷通过剩余污泥排除。

该工艺流程简单,污泥在厌氧、缺氧和好氧环境中交替运行,丝状菌不能大量繁殖,污泥沉降性能好。

在同时脱氧除磷的工艺中,该工艺流程最为简单,总的水力停留时间也少于同类其他工艺。

该法需要注意的问题。

进入沉淀池的混合液通常需要保持一定的溶解氧浓度,以防沉淀池中反硝化和污泥厌氧释磷,但这会导致回流污泥和回流混合液中存在一定的溶解氧,回流污泥中存在的硝酸盐对厌氧释磷过程也存在一定影响。

同时,系统所排放的剩余污泥中,仅有一部分污泥经历了完整的厌氧和好氧的过程,影响了污泥的充分吸磷,系统污泥龄因为兼顾硝化菌的生长而不可能太短,导致除磷效果难于进一步提高。

综上,充分考虑工艺的特点及进出水质的要求,最终确定选择工艺为本厂的污水处理工艺。

城镇污水处理设计说明书

城镇污水处理设计说明书

第一章前言1.1 城镇污水来源及危害城镇污水由城镇污水排水系统收集的生活污水和工业废水组成,是一种综合性污水。

生活污水主要来自家庭、商业、机关、学校、城镇公共设施及工厂的餐饮、卫生间、浴室、洗衣房等。

包括厕所冲洗水,厨房的洗涤水,洗衣排水,沐浴排水及其他排水等。

工业废水主要是在工业生产中被生产原料、中间产品或成品等物料所污染的水。

工业废水由于种类繁多,污染物成分及性质随生产过程而异,变化复杂。

往往含有有毒物质,有的含有易燃、易爆、腐蚀性强的污染物,需局部处理达标后才能排放。

1.2 城镇污水处理工艺简介分析该污水处理厂进水水质,进水BOD5 浓度最高位500mg/L,最低位191mg/L,进水的BOD5浓度在100~200 mg/L之间的频率为33.3%,进水的BOD5浓度在200~300 mg/L之间的频率为33.3%,进水的BOD5浓度大于300 mg/L的频率为33.3%,平均进水BOD5 浓度为645.74mg/L。

进水SS的浓度在120~240 mg/L之间的频率为60%,进水SS的浓度大于240 mg/L的频率为40%,平均SS的进水浓度为222.7mg/L。

最高进水COD的浓度为1000mg/L,最低进水COD的浓度为400mg/L,,平均进水COD浓度大于380mg/L,进水中COD和BOD5的含量均较小,所以选择好氧活性污泥法作为该城镇污水处理工艺,说行污泥法自发明以来,根据反映时间,进水方式,曝气设备,氧的来源,反应池型等的不同,已经发展出多种变型,。

传统活性污泥法作为最原始的处理方法,由于其耗氧速率高,易受冲击负荷的影响,需氧量不均等因素,在其基础上出现了渐减曝气法和阶段曝气法。

高负荷曝气法处理效果低,BOD5去除效果不超过70%~75%。

为了保证稳定运行,必须保证充分的搅拌和曝气,延时曝气法不易受冲击负荷的影响,但受费用的影响适用于小型污水处理系统,新型的曝气法还有吸附再生法、完全混合法、深层曝气法纯氧曝气法、克劳斯法、吸附降解工艺(AB法)、序批式活性污泥法(SBR法)、氧化沟等方法。

设计说明书污水处理厂

设计说明书污水处理厂

污水处理厂设计说明书目录第一章污水处理工程设计计算说明书1.1设计任务1.2设计内容1.3基本资料1.4设计水质水量计算第二章污水的一级处理2.1格栅设计计算2.2沉砂池设计计算2.3初次沉淀池设计计算第三章AA/O生物脱氮除磷工艺计算3.1设计参数3.2平面尺寸计算3.3进出水系统3.4其他管道设计3.5剩余污泥量第四章生物处理后处理4.1二次沉淀池设计计算4.2消毒设施计算4.3计量设备设计计算第五章污泥处理构筑物计算5.1污泥量计算5.2污泥浓缩池设计计算5.3贮泥池设计计算5.4污泥消化池设计计算5.5污泥脱水第六章污水处理厂布置6.1污水处理厂平面布置6.2污水处理厂高程布置第一章设计计算说明书1.1设计任务某城镇污水处理厂1.2设计内容1 •根据给定的原始资料,确定污水厂的规模和污水设计水量。

2 .按照原始资料数据进行处理方案的确定,拟定处理工艺流程,选择污水、污泥的处理构筑物,并用方框图表示。

进行工艺流程中各处理单元的处理原理说明。

3. 进行各构筑物的尺寸计算,各构筑物的设计参数应根据同类型污水的实际运行参数或参考有关手册选用。

4. 设备选型计算。

5. 平面和高程布置。

根据构筑物的尺寸,合理进行平面布置;高程布置应在完成各构筑物计算及平面布置草图后进行。

各处理构筑物应尽力采用重力流,各处理构筑物的水头损失可直接查相关资料,但各构筑物之间的连接管的水头损失则需计算确定。

6. 编写设计说明书、计算书。

1.3基本资料1、设计流量:Q 平=30000+ 28 X1000 m 3/d (No 学号,1 〜33 号)总变化系数:K Z= 1.42、污水水质:C0D=200-300mg/LBOD5=100-150 mg/LSS=200mg/LNH3-N=35 mg/LpH=6 〜93、受纳水体:位于城市的东侧自南向北,20年一遇洪水水位标高322.5m ,常水位标高320.3m。

4、选址:根据城市总体规划,污水厂拟建于该城市下游河流岸边,地势平坦,拟建处的地面标高326.30m。

10000立方米d城市污水处理厂综合设计综合设计说明书

10000立方米d城市污水处理厂综合设计综合设计说明书

综合实验与设计题目:10000m3/d城市污水处理厂综合设计专业: 环境工程年级: 2011级学号: 3211007605姓名: 廖燧娟指导教师: 谢光炎广东工业大学环境科学与工程学院2015年03月摘要我国水体污染主要来自两方面,一是工业发展超标排放工业废水,二是城市化中由于城市污水排放和集中处理设施严重缺乏,大量生活污水未经处理直接进入水体造成环境污染。

工业废水近年来经过治理虽有所减少,但城市生活污水有增无减,占水质污染的51%以上。

我国水体污染主要来自两方面,一是工业发展超标排放工业废水,二是城市化中由于城市污水排放和集中处理设施严重缺乏,大量生活污水未经处理直接进入水体造成环境污染。

工业废水近年来经过治理虽有所减少,但城市生活污水有增无减,占水质污染的51%以上。

本设计要求处理水量为10000m3/d的城市生活污水,设计方案针对已运行稳定有效的A2/O活性污泥法工艺处理城市生活污水。

A2O工艺由于不同环境条件,不同功能的微)能生物群落的有机配合,加之厌氧、缺氧条件下,部分不可生物降解的有机物(CODNB被开环或断链,使得N、P、有机碳被同时去除,并提高对COD的去除效果。

它可以同NB--时完成有机物的去除,硝化脱氮、磷的过量摄取而被去除等功能,脱氮的前提是NH3N应完全硝化,好氧池能完成这一功能,缺氧池则完成脱氮功能。

厌氧池和好氧池联合完成除磷功能。

关键词:城市生活污水,活性污泥,A2/O目录摘要 (II)目录 (III)第一章设计概述 ······································································- 1 -1设计任务 ······································································- 1 - 2设计原则 ······································································- 1 - 3设计依据 ······································································- 2 - 第二章工艺流程及说明 ·····························································- 2 -1工艺方案分析 ································································- 2 - 2工艺流程 ······································································- 3 - 3流程各结构介绍 ·····························································- 3 -3.1格栅······························································································· - 3 -3.2沉砂池··························································································· - 4 -3.3初沉池··························································································· - 4 -3.4生物化反应池··············································································· - 4 -3.5二沉池··························································································· - 6 -3.6浓缩池··························································································· - 6 - 第三章构筑物设计计算 ·····························································- 6 -1格栅 ············································································- 6 -1.1设计说明······················································································· - 6 -1.2设计计算······················································································· - 7 -2沉砂池 ······································································· - 10 -2.1设计说明······················································································- 10 - 3初沉池 ······································································· - 11 -3.1设计说明······················································································- 11 -3.2设计计算······················································································- 11 - 4生化池 ······································································· - 12 -4.1设计说明······················································································- 12 -4.2设计计算······················································································- 13 - 5二沉池 ······································································· - 20 -5.1设计说明······················································································- 20 -5.2设计计算······················································································- 20 - 6液氯消毒 ···································································· - 23 -6.1设计说明······················································································- 23 -6.2设计计算······················································································- 23 - 7污泥浓缩池 ································································· - 24 -7.1设计说明······················································································- 24 -7.2设计计算······················································································- 24 -8 污泥消化池 ································································· - 25 -8.1设计说明······················································································- 25 -8.2设计计算······················································································- 26 - 9浓缩污泥提升泵房 ························································ - 32 -9.1设计选型······················································································- 32 -9.2提升泵房······················································································- 32 -9.3污泥回流泵站··············································································- 32 -10污泥脱水间 ······························································· - 33 -10.1设计说明······················································································- 33 -11鼓风机房 ·································································· - 33 - 12恶臭处理系统 ···························································· - 33 -12.1设计说明······················································································- 33 -12.2设计计算······················································································- 33 -12.3风机选型······················································································- 34 - 第四章污水处理厂总体布置 ····················································· - 35 -1总平面布置 ································································· - 35 -1.1总平面布置原则··········································································- 35 -1.2总平面布置结果··········································································- 35 -2高程布置 ·································································································- 36 -2.1高程布置原则··············································································- 36 - 第五章参考文献 ···································································· - 36 -第一章设计概述1设计任务本次课程设计的主要任务是完成某城市污水厂的A2/O工艺设计处理生活污水,处理水量为10000m3/d,按近期规划人口10万人计算(自定)。

(完整版)污水处理厂工艺设计说明计算书:城市生活污水,2.0万吨每天,AO活性污泥法

(完整版)污水处理厂工艺设计说明计算书:城市生活污水,2.0万吨每天,AO活性污泥法

第一章 污水处理构筑物设计计算一、粗格栅1.设计流量Q=20000m 3/d ,选取流量系数K z =1.5则: 最大流量Q max =1.5×20000m 3/d=30000m 3/d =0.347m 3/s2.栅条的间隙数(n )设:栅前水深h=0.4m,过栅流速v=0.9m/s,格栅条间隙宽度b=0.02m,格栅倾角α=60° 则:栅条间隙数85.449.04.002.060sin 347.0sin 21=⨯⨯︒==bhv Q n α(取n=45)3.栅槽宽度(B)设:栅条宽度s=0.01m则:B=s (n-1)+bn=0.01×(45-1)+0.02×45=1.34m 4.进水渠道渐宽部分长度设:进水渠宽B 1=0.90m,其渐宽部分展开角α1=20°(进水渠道前的流速为0.6m/s ) 则:m B B L 60.020tan 290.034.1tan 2111=︒-=-=α5.栅槽与出水渠道连接处的渐窄部分长度(L 2)m L L 30.0260.0212===6.过格栅的水头损失(h 1)设:栅条断面为矩形断面,所以k 取3则:m g v k kh h 102.060sin 81.929.0)02.001.0(4.23sin 2234201=︒⨯⨯⨯⨯===αε其中ε=β(s/b )4/3k —格栅受污物堵塞时水头损失增大倍数,一般为3 h 0--计算水头损失,mε--阻力系数,与栅条断面形状有关,当为矩形断面时形状系数β=2.4将β值代入β与ε关系式即可得到阻力系数ε的值7.栅后槽总高度(H)设:栅前渠道超高h 2=0.3m则:栅前槽总高度H 1=h+h 2=0.4+0.3=0.7m栅后槽总高度H=h+h 1+h 2=0.4+0.102+0.3=0.802m 8.格栅总长度(L)L=L 1+L 2+0.5+1.0+ H 1/tan α=0.6+0.3+0.5+1.0+0.7/tan60°=2.8 9. 每日栅渣量(W)设:单位栅渣量W 1=0.05m 3栅渣/103m 3污水则:W=Q W 1=05.0105.130000100031max ⨯⨯=⨯⨯-Z K W Q =1.0m 3/d 因为W>0.2 m 3/d,所以宜采用机械格栅清渣 10.计算草图:图1-1 粗格栅计算草图二、集水池设计集水池的有效水深为6m,根据设计规范,集水池的容积应大于污水泵5min 的出水量,即:V >0.347m 3/s ×5×60=104.1m 3,可将其设计为矩形,其尺寸为3m ×5m ,池高为7m ,则池容为105m 3。

污水处理厂设计

污水处理厂设计

污水处理厂设计随着城市化进程的加快,污水处理成为了城市发展中重要的环境问题之一。

为了确保城市污水的排放符合环保标准,提高水资源的可持续利用率,设计一座高效的污水处理厂显得尤为重要。

本文将从设计理念、污水处理工艺和设备选型以及运营管理等方面,细致论述如何进行污水处理厂的设计。

一、设计理念设计一座污水处理厂的首要任务是确保污水能够达到国家及地方的排放标准,同时降低对环境的污染。

在设计理念上,应该坚持“节能、环保、可持续发展”的原则。

污水处理厂的建设应该采用尽可能少的能源,并且减少二氧化碳等温室气体的排放。

此外,采用先进的污水处理工艺和设备,确保出水质量达标,以保护水资源的可持续利用。

二、污水处理工艺和设备选型根据不同的污水水质和处理要求,我们可以选择不同的污水处理工艺和设备。

常用的污水处理工艺包括物理处理、化学处理和生物处理。

物理处理主要是通过混凝和沉淀等方法,去除污水中的悬浮物和固体颗粒。

化学处理则通过投加化学药剂,去除污水中的有机物和重金属等。

而生物处理则利用微生物的活性,降解污水中的有机物和氮、磷等有害物质。

在设备选型方面,应根据污水处理厂的规模和实际需求选用适合的设备。

常见的设备包括格栅、沉砂池、曝气池、二沉池、除磷除氮设备等。

格栅用于拦截污水中的大颗粒杂物,沉砂池用于去除污水中的泥沙颗粒,曝气池提供氧气供给生物降解有机物,二沉池用于污泥和污水的分离,除磷除氮设备则用于去除污水中的磷和氮等有害物质。

三、运营管理污水处理厂的建设完成后,运营管理的质量将直接影响污水处理的效果。

为了保证污水处理厂的正常运行,需采取一系列的管理措施。

首先,建立科学的排污制度,严格执行污水排放标准。

其次,进行定期的设备检查和维护,确保设备正常运行。

此外,加强对操作人员的培训,提高其技能水平,提升污水处理效果。

结语污水处理厂的设计是为了保护水资源,保障环境质量,提高城市的可持续发展能力。

在设计过程中,我们应坚持节能、环保、可持续发展的理念,选用适合的污水处理工艺和设备,并加强运营管理,确保污水处理厂的正常运行。

(完整版)污水处理厂工艺设计说明计算书:城市生活污水,4.4万吨每天,A2O活性污泥法

(完整版)污水处理厂工艺设计说明计算书:城市生活污水,4.4万吨每天,A2O活性污泥法

污水处理厂工艺设计一、污水处理厂的设计规模(一)污水处理厂的设计规模污水处理厂以处理水量的平均日平均时流量计,该市污水厂的处理规模定为:近期4.4万m3/d,远期6.6万m3/d,见表:污水处理厂的设计规模(二)污水处理厂处理构筑物规模污水处理厂的主要构筑拟分成三组,每组处理规模为2.2万m3/d,近期建2组,处理规模为4.4万m3/d,远期再建1组,处理规模扩至6.6万m3/d,污水厂占地约5.9ha,用地指标为0.89 m2/(m3污水/d)(三)设计流量当污水厂分建时,以相应的各期流量作为设计流量。

各设计流量的具体数据见表。

污水处理厂的设计流量二、污水处理程度的确定(一)进水水质根据原始资料,污水处理厂实测污水水质及设计水质见表:污水的实测水质,设计进水水质、出水水质标准(二)设计出水水质出水水质要求符合GB8978-96《防水综合排放标准》根据出水水质要求,污水处理厂既要求有效地去除BOD 5,又要求对污水中的氮,磷进行适当处理,防止A 江的富营养化。

(三)处理程度计算 1.溶解性BOD 5去除率活性污泥处理系统处理水中的BOD 5值是由残存的溶解性BOD 5(Se )和非溶解性BOD 5二者组成,而非溶解性BOD 5主要以生物污泥的残屑为主体。

活性污泥的净化功能,是去除溶解性BOD 5,故从活性污泥的净化功能考虑,应将非溶解性BOD 5从处理水的总BOD 5值中减去。

处理水中非溶解性BOD 5值: BOD 5=7.1·b ·Xa ·Ce式中 Ce ——处理水中悬浮固体浓度,取25mg/Lb ——微生物自身氯化率,一般介于0.05~0.1,之间,取0.09 Xa ——活性微生物在处理水中所占比例,取0.4 故 BOD 5=7.1×0.09×0.4×25≈6.4 处理水中溶解性BOD 5值为: 25-6.4=18.6mg/L 去除率:%1.97%1002204.6220=⨯-=η 2.CODcr 的去除率: %35.82%10034060340=⨯-=η 3.SS 的去除率%75.93%10032020320=⨯-=η 4.总氮的去除率出水标准中的总氮为15mg/L ,故去除率为: %70%100501550=⨯-=η 5.磷酸盐的去除率进水中磷酸盐浓度为6.8~9.4mg/L ,按9.4 mg/L 计,如磷酸盐以最大可能成分Na 3PO 4计,则磷的含量为1.7 mg/L 。

城市污水处理厂设计说明书

城市污水处理厂设计说明书

污水厂设计说明书一、污水厂的设计规模设计规模:污水厂的处理水量按最高日最高时流量,污水厂的日处理量为:该厂按远期2010年一期2。

6万吨/天建设完成,污水厂主要处理构筑物拟分为二组,每组处理规模为1。

3万吨/天.这样既可满足近期处理水量要求,有留有空地以三期扩建之用.远期2。

6万吨,一期建设,计算主要按远期计算,由于没有工业废水的变化系数,所以按生活污水量来取其时变化系数。

二、进出水水质该水经处理以后,水质应符合国家《污水综合排放标准》(GB8978-1996)中的一级标准,由于进水不但含有BOD5,还含有大量的N,P所以不仅要求去BOD5除还应去除不中的N,P达到排放标准。

三、处理程度的计算1。

溶解性BOD5的去除率活泩污泥处理系统处理水中的BOD5值是由残存的溶解性BOD5和非溶解性BOD5二者组成,而后者主要是以生物污泥的残屑为主体。

活性污泥的净化功能,是去除溶解性BOD5。

因此从活性污泥的净化功能来考虑,应将非溶解性的BOD5从处理水的总BOD5值中减去。

处理水中非溶解性BOD5值可用下列公式求得:(此公式仅适用于氧化沟)处理水中溶解性BOD5为20-13。

6=6.4mg/L溶解性BOD5的去除率为:2 .CODcr的去除率3.SS的去除率4。

总氮的去除率出水标准中的总氮为15mg/L,处理水中的总氮设计值取15mg/L,总氮的去除率为:5.磷酸盐的去除率进水中磷酸盐的浓度为4.9mg/L计.如磷酸盐以最大可能成Na3PO4计,则磷的含量为4.9×0。

189=0.93mg/L.注意:Na3PO4中P的含量在可能存在的磷酸盐(溶解性)中是含量最大的,这样计算出来的进水水质中的磷含量偏大,对整个设计来说是偏安全的。

磷的去除率为四、城市污水处理设计1、工艺流程的比较城市污水处理厂的方案,既要考虑有效去除BOD5又要适当去除N,P故可采用SBR或氧化沟法,或A/A/O法,以及一体化反应池即三沟式氧化沟得改良设计.A SBR法工艺流程:污水→一级处理→曝气池→处理水工作原理:1)流入工序:废水注入,注满后进行反应,方式有单纯注水,曝气,缓速搅拌三种,2)曝气反应工序:当污水注满后即开始曝气操作,这是最重要的工序,根据污水处理的目的,除P脱N应进行相应的处理工作。

某城市日处理水量3万立方米污水处理厂工艺设计

某城市日处理水量3万立方米污水处理厂工艺设计

第1章总论1.1给水处理课程设计任务及要求1.1.1设计题目某城市日处理水量3万m3污水处理厂工艺设计1.1.2 基本资料1、污水水量、水质(1)设计规模设计日平均污水流量Q=30000m3/d;=1500m3/h设计最大小时流量Qmax(2)进水水质污水水质:COD Cr450mg/L,BOD5200mg/L,SS250mg/L,氨氮15mg/L。

2、污水处理要求污水经一级处理后应符合以下具体要求:COD Cr≤260mg/L,BOD5≤150mg/L,SS≤125mg/L,氨氮不变污水经二级处理后应符合以下具体要求:COD Cr≤70mg/L,BOD5≤20mg/L,SS≤30mg/L,氨氮≤5mg/L。

3、处理工艺流程污水拟采用传统活性污泥法工艺处理,具体流程如下:污水格栅间污水泵房沉沙池配水井初沉池二沉池混合池配水井回流泵辐流接触池出水4、气象资料风向:多年主导风向为东北风;气温:最冷月平均为-3.5℃;最热月平均为32..5℃;极端气温,最高为41.9℃,最低为-17.6℃,最大冻土深度为0.18m;水文:降水量多年平均为每年728mm;蒸发量多年平均为每年1210mm;地下水水位,地面下5~6m。

5、污水排水接纳河流资料:污水厂选址区域海拔标高在64~66m之间,平均地面标高为64.5m。

平均地面坡度0.3‰~0.5‰,地势为西北高,东南低。

厂区征地面积为东西长380m,南北长280m。

场地坐标: X 0.00 380.00 0.00 380.00Y 0.00 0.00 280.00 280.00来水方位:X:100.00 Y: 50.00管内底标高:57.21米;管径D=180mm;充满度h/D=0.7接纳水体:位于厂区西边,最高水位:56.08m1.1.3 设计任务1、总体要求(1)在设计过程中,要发挥独立思考独立工作的能力;(2)本课程设计的重点训练,是污水处理主要构筑物的设计计算和总体布置。

日处理2.5万立方米污水处理厂的工艺流程设计.doc

日处理2.5万立方米污水处理厂的工艺流程设计.doc

日处理2.5万立方米污水处理厂的工艺流程设计设计任务书1 设计任务某化工区2.5万m3/d污水处理厂设计2 任务的提出及目的,要求2.1 任务的提出及目的:随着经济飞速发展,人民生活水平的提高,对生态环境的要求日益提高,要求越来越多的污水处理后达标排放。

在全国乃至世界范围内,正在兴建及待建的污水厂也日益增多。

有学者曾根据日处理污水量将污水处理厂分为大、中、小三种规模:日处理量大于10万m3为大型处理厂,1-10m3万为中型污水处理厂,小于1万m3的为小型污水处理厂。

近年来,大型污水处理厂建设数量相对减少,而中小型污水厂则越来越多。

如何搞好中、小型污水处理厂,特别是小型污水厂,是近几年许多专家和工程技术人员比较关注的问题。

根据所确定的工艺和计算结果,绘制污水处理厂总平面布置图,高程图,工艺流程图。

2.2 要求:2.2.1 方案选择合理,确保污水经处理后的排放水质达到国家排放标准2.2.2 所选厂址必须符合当地的规划要求,参数选取与计算准确 2.2.3 全图布置分区合理,功能明确;厂前区,污水处理区污泥处理区条块分割清楚。

延流程方向依次布置处理构筑物,水流创通。

厂前区布置在上风向并用绿化隔离带与生产区隔离,以尽量减少对厂前区的影响,改善厂前区的工作环境。

2.2.4 构筑物的布置应给厂区工艺管线和其他管线设有余地,一般情况下,构筑物外墙距道路边不小于6米。

2.2.5 厂区设置地坪标高尽量考虑土方平衡,减少工程造价,同时满足防洪排涝要求。

2.2.6 水力高程设计一般考虑一次提升,利用重力依次流经各个构筑物,配水管的设计需优化,以尽量减少水头损失,节约运行费用。

2.2.7 设计中应该避免磷的再次产生,一般不主张采用重力浓缩池,而是采用机械浓缩脱水的方式,随时将排出的污泥进行处理。

2.2.8 所选设备质优、可靠、易于操作。

并且设计必须考虑到方便以后厂区的改造。

2.2.7 附有平面图,高程图各一份。

详情请下载附件:日处理2.5万立方米污水处理厂的工艺流程设计。

30000m3d处理规模城市污水处理厂(课程)设计

30000m3d处理规模城市污水处理厂(课程)设计

课程设计题目:30000m3/d处理规模城市污水处理厂(课程)设计学生学院环境科学与工程学院专业班级学号学生姓名指导教师2013 年 6 月目录一污水处理厂设计任务书 (4)设计题目 (4)设计目的 (4)设计进出水水质 (4)设计依据 (4)二污水处理工艺选择及说明 (5)工艺选择 (5)工艺方案分析 (6)三工艺流程设计计算 (6)设计流量的确定 (6)格栅 (7)设计说明 (7)中格栅计算 (8)栅渣量计算 (9)污水提升泵站 (10)设计说明 (10)泵的选型 (10)泵后细格栅设计计算 (11)细格栅设计说明 (11)栅渣量计算 (12)平流式沉砂池 (13)设计说明 (13)池体设计计算 (13)厌氧池 (15)设计计算 (15)氧化沟的设计计算 (16)设计参数 (16)设计计算 (17)二沉池 (21)设计参数 (21)池体设计计算 (21)接触消毒池与加氯时间的设计计算 (23)设计参数 (23)设计计算 (23)回流污泥泵房 (25)设计说明 (25)回流泵设计选型 (25)剩余污泥泵房 (26)设计说明 (26)设计选型 (26)污泥浓缩池 (27)设计参数 (27)设计计算 (27)贮泥池及污泥泵 (29)设计参数 (29)设计计算 (29)四污水处理厂总体布置 (30)平面布置 (30)管路布线 (30)五设计心得 (31)六参考文献 (32)一污水处理厂设计任务书设计题目30000m³/d处理规模城市污水处理厂生物处理工艺设计设计目的建设污水处理厂是控制水污染的有效手段,也是城市基础建设的一个重要环节,这一目标的实现与否,不仅直接影响该市各项功能的发挥,也标志着城市基础建设的完善程度,成为衡量城市现代化的标准之一,污水处理厂的建设,不仅反映城市的经济实力、人口素质和社会文明水平,也可以通过污水的集中处理,降低企业和社区污水处理的费用,减少企业的生产成本,从而增加对内资和外资的吸引力。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

第 1 章概述1.1 基本设计资料课程设计名称某市11万吨/天城市污水处理厂初步设计基本资料:1.设计规模K污水设计流量:Q=11立方米/天,流量变化系数: 1.2Z2.原污水水质指标BOD=280mg/L COD=380mg/L SS=200mg/L NH3-N=42mg/L pH=6--93.出水水质指标BOD=20mg/L COD=60mg/L SS=20mg/L NH3-N=15mg/L pH=6--94.气象资料区域主导风向西南风。

污水干管管底埋深为地面以下7.3米。

在季节分配上,夏季降水量最多,占全年总降水量的75%以上,冬季最少,仅占2%。

由于降水量年内分配不均和年际变化大,造成某在历史上经常出现春旱秋涝现象。

5.厂址及场地状况原污水将通过管网输送到污水厂,来水管管底标高为 7.3米(于地面下7.3米)。

最大冻土层1.5米。

充满度0.5。

河道的最高洪水水位标高140.00米。

常水位标高为131.00米。

枯水位标高为119.00米。

1.2 设计内容、原则1.2.1 设计内容污水处理厂工艺设计流程设计说明一般包括以下内容:(1)据城市或企业的总体规划或现状与设计方案选择处理厂厂址;(2)处理厂工艺流程设计说明;(3)处理构筑物型式选型说明;(4)处理构筑物或设施的设计计算;(5)主要辅助构筑物设计计算;(6)主要设备设计计算选择;(7)污水厂总体布置(平面或竖向)及厂区道路、绿化和管线综合布置;(8)处理构筑物、主要辅助构筑物、非标设备设计图绘制;(9)编制主要设备材料表。

1.2.2 设计的原则考虑城市经济发展及当地现有条件,确定方案时考虑以下原则:(1)要符合适用的要求。

首先确保污水厂处理后达到排放标准。

考虑现实的技术和经济条件,以及当地的具体情况(如施工条件),在可能的基础上,选择的处理工艺流程、构(建)筑物型式、主要设备、设计标准和数据等,应最大限度地满足污水厂功能的实现,使处理后污水符合水质要求。

(2)污水厂设计采用的各项设计参数必须可靠。

(3)污水处理厂设计必须符合经济的要求。

设计完成后,总体布置、单体设计及药剂选用等要尽可能采取合理措施降低工程造价和运行管理费用。

(4)污水处理厂设计应当力求技术合理。

在经济合理的原则下,必须根据需要,尽可能采用先进的工艺、机械和自控技术,但要确保安全可靠。

(5)污水厂设计必须注意近远期的结合,不宜分期建设的部分,如配水井、泵房及加药间等,其土建部分应一次建成;在无远期规划的情况下,设计时应为以后的发展留有挖潜和扩建的条件。

(6)污水厂设计必须考虑安全运行的条件,如适当设置分流设施、超越管线等。

第 2 章工艺方案的选择2.1 水质分析本项目污水处理的特点:污水以有机污染物为主,BOD/COD=0.74,可生化性较好,采用生化处理最为经济。

BOD/TN>3.8,COD/TN>6.0,满足反硝化需求;若BOD/TN>5,氮去除率大于60%。

2.2 工艺选择按《城市污水处理和污染防治技术政策》要求推荐,20万t/d规模大型污水厂一般采用常规活性污泥法工艺,10-20万t/d 污水厂可以采用常规活性污泥法、氧化沟、SBR、AB 法等工艺,小型污水厂还可以采用生物滤池、水解好氧法工艺等。

对脱磷或脱氮有要求的城市,应采用二级强化处理,如2/A O工艺,A/O工艺,SBR 及其改良工艺,氧化沟工艺,以及水解好氧工艺,生物滤池工艺等。

2.2.1 方案对比工艺类型氧化沟SBR法A/O法技术比较经济比较使用范围稳定性1.污水在氧化沟内的停留时间长,污水的混合效果好2.污泥的BOD负荷低,对水质的变动有较强的适应性可不单独设二沉池,使氧化沟二沉池合建,节省了二沉池和污泥回流系统中小流量的生活污水和工业废水一般1.处理流程短,控制灵活2系统处理构筑物少,紧凑,节省占地投资省,运行费用低,比传统活性污泥法建费用低30%中小型处理厂居多一般1.低成本,高效能,能有效去除有机物2.能迅速准确地检测污水处理厂进出水质的变化。

能耗低,运营费用较低,规模越大优势越明显大中型污水处理厂稳定考虑该设计是中型污水处理厂,A/O工艺比较普遍,稳定,且出水水质要求不是很高,本设计选择A/O工艺。

2.2.2 工艺流程污水处理流程图污泥处理流程图第 3 章 污水处理构筑物的设计计算3.1中格栅及泵房格栅是由一组平行的金属栅条或筛网制成,安装在污水渠道上、泵房集水井的进口处或污水处理厂的端部,用以截留较大的悬浮物或漂浮物。

本设计采用中细两道格栅。

3.1.1 中格栅设计计算1.设计参数: 最大流量:s m Kz Q ax /5.12436002.111000Qm 3=⨯⨯=•=栅前水深:0.4h m =,栅前流速: 10.9/v m s =(0.4/~0.9/m s m s )过栅流速20.9/v m s =(0.6/~1.0m s /m s )栅条宽度0.01S m =,格栅间隙宽度0.04b m =格栅倾角060α=2.设计计算:(1)栅条间隙数:979.04.004.060sin 5.1bhv sin60Qmax n =⨯⨯⨯=•=根 设四座中格栅:2541001==n 根 (2)栅槽宽度:设栅条宽度0.01S m =1.24m 2504.0)125(01.0)1S(n B 11=⨯+-⨯=+-=bn(3)进水渠道渐宽部分长度:设进水渠道宽 1.04m B 1=,渐宽部分展开角度20α=o m B B l 28.020tan 204.124.120tan 211=-=-=οο 根据最优水力断面公式m vh Q B 04.14.09.045.14max 1=⨯⨯== (4)栅槽与出水渠道连接处的渐宽部分长度:m l l 14.0228.0212===(5)通过格栅的水头损失:02h K h ⨯=220sin 2v h g ξα=,43s b ξβ⎛⎫=⨯ ⎪⎝⎭ h 0 ───── 计算水头损失;g ───── 重力加速度;K ───── 格栅受污物堵塞使水头损失增大的倍数,一般取3;ξ───── 阻力系数,其数值与格栅栅条的断面几何形状有关,对于锐边矩形断面,形状系数β = 2.42;4220.010.93 2.42sin 600.0410.0429.81h ⎛⎫=⨯⨯⨯⨯≈ ⎪⨯⎝⎭o m (6)栅槽总高度:设栅前渠道超高20.3h m =120.40.0410.30.741H h h h m =++=++=(7)栅槽总长度: 1120.5 1.0tan H L L L α=++++ο60tan 0.30.41.00.50.140.28+++++= =2.4m (8)每日栅渣量:格栅间隙40mm 情况下,每31000m 污水产30.03m 。

3.241.210000.031.586400100086400Q W Z 1max =⨯⨯⨯==K W 3/d m 30.2/m d > 所以宜采用机械清渣。

(9)格栅选择选择XHG-1400回转格栅除污机,共4台。

其技术参数见下表。

表3-1-1 GH-1800链式旋转除污机技术参数型号 电机功 率/kw 设备宽度/mm 设备总宽度/mm 栅条间隙/mm 安装角度HG-1800 1.5 1800 2090 40 60°3.1.2 污水提升泵房泵房形式取决于泵站性质,建设规模、选用的泵型与台数、进出水管渠的深度与方位、出水压力与接纳泵站出水的条件、施工方法、管理水平,以及地形、水文地质情况等诸多因素。

泵房形式选择的条件:(1)由于污水泵站一般为常年运转,大型泵站多为连续开泵,故选用自灌式泵房。

(2)流量小于32/m s 时,常选用下圆上方形泵房。

(3)大流量的永久性污水泵站,选用矩形泵房。

(4)一般自灌启动时应采用合建式泵房。

综上本设计采用半地下自灌式合建泵房。

自灌式泵房的优点是不需要设置引水的辅助设备,操作简便,启动及时,便于自控。

自灌式泵房在排水泵站应用广泛,特别是在要求开启频繁的污水泵站、要求及时启动的立交泵站,应尽量采用自灌式泵房,并按集水池的液位变化自动控制运行。

集水池:集水池与进水闸井、格栅井合建时,宜采用半封闭式。

闸门及格栅处敞开,其余部分尽量加顶板封闭,以减少污染,敞开部分设栏杆及活盖板,确保安全。

1选泵(1)进水管管底高程为7.3m ,管径500DN ,充满度0.5。

(2)出水管提升后的水面高程为12.80m 。

(3)泵房选定位置不受附近河道洪水淹没和冲刷,原地面高程为10.0m 。

2.设计计算(1)污水平均秒流量:13510000001562.5/86400Q L s ⨯== (2)污水最大秒流量:11562.5 1.21875/Z Q K Q L s ==⨯=g选择集水池与机器间合建式泵站,考虑4台水泵(1台备用)每台水泵的容量为1875625/3L s =。

(3)集水池容积:采用相当于一台泵6min 的容量。

36256062251000W m ⨯⨯== 有效水深采用2H m =,则集水池面积为2112.5F m =(4)选泵前扬程估算:经过格栅的水头损失取0.1m集水池正常工作水位与所需提升经常高水位之间的高差:()12.850.50.750.118.53m -+⨯--=(集水池有效水深2m ,正常按1m 计)(5)水泵总扬程:总水力损失为2.80m ,考虑安全水头0.5m2.88.530.511.83H m =++=一台水泵的流量为31150000 1.22500/324324Z Q K Q m h ⨯===⨯⨯g 根据总扬程和水量选用500270016185WQ --型潜污泵表3-1-2 500WQ2700-16-185型潜污泵参数型号 流量 3/m h 转速 /min r扬程 m 功率 kW 效率 % 出水口 直径mm 500270016185WQ -- 2700 725 16 185 82 5003.2 细格栅3.2.1 细格栅设计计算1.设计参数: 最大流量:3max 120000 1.2 1.67/360024Z Q Q K m s ⨯===⨯g 栅前水深:0.4h m =,栅前流速:10.9/v m s =(0.4/~0.9/m s m s )过栅流速:20.9/v m s =(0.6/~1.0m s /m s )栅条宽度:0.01S m =,格栅间隙宽度0.01b m =格栅倾角:α=60o2.设计计算(1)栅条间隙数:432n ===根 设四座细格栅:14321443n ==根 (2)栅槽宽度:设栅条宽度0.01S m =()()1110.0114410.01144 2.87B S n bn m =-+=⨯-+⨯=(3)进水渠道渐宽部分长度:设进水渠道宽1 1.55B m =,渐宽部分展开角度20α=o 111 2.87 1.55 1.832tan 2tan 20B B l m α--===o 根据最优水力断面公式max 1 1.67 1.55330.90.4Q B m vh ===⨯⨯ (4)栅槽与出水渠道连接处的渐宽部分长度:12 1.830.91522l l m === (5)通过格栅的水头损失:02h K h ⨯=220sin 2v h g ξα=,43s b ξβ⎛⎫=⨯ ⎪⎝⎭ h 0 ——计算水头损失;g ——重力加速度;K ——格栅受污物堵塞使水头损失增大的倍数,一般取3;ξ——阻力系数,其数值与格栅栅条的断面几何形状有关,对于锐边矩形断面,形状系数β = 2.42;43220.010.93 2.42sin 600.260.0129.81h ⎛⎫=⨯⨯⨯⨯= ⎪⨯⎝⎭o m (6)栅槽总高度:设栅前渠道超高20.3h m =120.40.260.30.96H h h h m =++=++=(7)栅槽总长度: 1120.5 1.0tan H L L L α=++++0.40.31.830.9150.5 1.0tan 60+=++++o 4.6m = (8)每日栅渣量:格栅间隙10mm 情况下,每31000m 污水产30.1m 。