1.2.1 系统设计.....................................................................................................................................................................1 1.2.2 旁路 ............................................................................................................................................................................1 1.2.3 系统控制原理.............................................................................................................................................................2 1.2.4 ECO 模式(只适用于 UPS 单机)............................................................................................................................3 1.2.5 UPS 电源开关配置 .....................................................................................................................................................3 1.2.6 电池开关.....................................................................................................................................................................3 1.2.7 电池温度补偿.............................................................................................................................................................3 1.2.8 系统扩容.....................................................................................................................................................................4 1.3 运行模式.................................................................................................................................................................................4 第二章 机械安装 ................................................................................................................................................................. 5

SWP201温度变送器

SWP201温度变送器

30~350Ω -1999~99999 d
02
S
0 ~1600 ℃
10
Cu50 -50.0~150.0 ℃ 18 特 殊 规 格 用 户 特 定
03
K
0 ~1300 ℃
11
Cu100 -50.0~150.0 ℃ 19 4~20 mA开方 -1999~99999 d
04
E
0 ~1000 ℃
12 4~20 mA -1999~99999 d 20 0~10mA开方 -1999~99999 d1Leabharlann 单路2双路
模块功能
TC
TR
热电偶 热电阻
输入信号
□□
参见“输入信号”
第一路 输出方式
1
1~5V
2
4~20mA
第二路 输出方式
0 无第二路输出(可省略) 1 第二路输出为 1~5V 输出 2 第二路输出为 4~20mA 3 第二路输出为报警触点控制 4 第二路输出 RS-232 通讯接口
供电方式
5
第二路输出 RS-485 通讯接口
一、仪表特点
1、内部采用微处理器进行数学运算,可对各种非线性输入信号进行处理。配用 SWP20SH 显示模块,可将输入信号所对应的 温度值以数字方式方便直观的显示出来。
1、可选交直流两种电源,变送输出与主机隔离,具有 1~5V DC 或 4~20mA DC 输出信号的选择功能和断偶保护功能。
二、仪表参数及接线图
苏州迅鹏仪器仪表有限公司
SWP 系列智能仪表
DP/DT 转速/线速度显示控制仪
SWP201(单路) SWP202(双路)
热电偶/热电阻温度变送器
SWP20 系列温度变送模块是一种小型化插装式结构的温度变送模块。它将来自热电偶的热电动势或热电阻的阻值变换成 为与温度成比例的隔离 1~5V DC 或 4~20mA DC 输出信号。

温特斯PCT200(普通)温度变送器使用说明书

温特斯PCT200(普通)温度变送器使用说明书

PCT200(普通)温度变送器特点■安装方便■高强度,抗高压■一体化结构■能长期稳定工作■响应快■结构可靠用途及行业■设备配套■泵及压缩机、天然气管网等自动化温度测控系统■石油、化工、电力、轻纺、环保等领域中对水或油的温度测量注意:1测温时,测温元件要与被测对象达到热平衡。

2插入深度要准确。

3安装前请仔细阅读产品使用说明书,并核对产品的相关信息。

4严格按照接线方式接线,否则会导致产品损坏和其他潜在故障。

5错误的使用,会导致危险和人身伤害。

产品概述PCT200(普通)活动接头温度变送器是为方便安装专门设计的一款变送器。

变送器采用了高性能、高可靠进口铂电阻,经过精密的温度和非线性补偿,采用性能良好的模块化信号处理工艺技术,对介质温度进行测量校准,输出工业控制标准信号。

产品外壳采用全不锈钢一体化加工,具有体积小、热响应快等特点;导线采用专用屏蔽导线,使用温度范围宽;该产品安装方便,具有极高的抗振和抗冲击性能。

注意:1文件不要误用。

2本选型中的信息仅供参考,不可用此文件作为产品安装指导。

3在产品说明书上提供了完整的安装、操作和维护资料。

4错误的使用,会导致危险和人身伤害。

性能参数量程范围-50℃~250℃供电输出4~20mA(16~36VDC)精度±0.5%FS敏感元件Pt100A级绝缘强度100MΩ/250VDC响应时间≤30s(10%-90%)长期稳定性≤0.2%FS/年置入直径Φ8mm储存温度-40℃~85℃电气连接大赫斯曼防护等级IP65材料304最大安装扭矩25Nm外形结构尺寸图单位:mm螺纹接口螺纹代码C1:M20×1.5-6g C2:G1/2C7:NPT1/2尺寸图单位:mm建议扭矩15~25Nm15~25Nm15~25Nm 注:扭矩取决于各种因素,例如垫片材料、配套材料、螺纹润滑及压力大小。

量程选择量程代码量程范围备注(-50~100)-50℃~100℃(-50~150)-50℃~150℃(-50~200)-50℃~200℃(-50~250)-50℃~250℃(0~100)0℃~100℃(0~150)0℃~150℃(0~200)0℃~200℃(0~250)0℃~250℃配件名称外形描述物料号赫斯曼插头OMAL100040301013带线赫斯曼插头OMAL 1.5m 100040301018液晶显示表LCD12100040100008选型PCT200(普通)--50~100)B1C1L050举例:PCT200(普通)-(-50~150)B1C1L050表示型号为PCT200(普通),量程为-50℃~150℃,供电电源为16~36VDC,输出信号为4~20mA,螺纹接口为M20×1.5-6g,插入深度50mm。

康斯特CST2002智能数字压力校验仪操作规程

康斯特CST2002智能数字压力校验仪操作规程

康斯特CST2002智能数字压力校验仪操作规程一、使用范围:检定差压变送器、压力变送器、各种压力(微压)表、压力开关二、生产厂家、规格型号、安装位置:1、生产厂家:北京康斯特2、规格型号:康斯特CST2002 产品编号:2221843、安装位置:压力检定室(轮南计量工作站)三、辅助设备:1、充电器2、专用测试线3、手压泵4、接头四、技术要求:技术指标1、压力范围及准确度:负压模块(0~-100Kpa), 正压模块(0~40Kpa),(0~250Kpa),(0~1Mpa),(0~2.5Mpa),(0~20Mpa)以上六个压力模块准确度均为±0.05%F.S 。

2、直流电输出:24DVC 直流测试:0~25mA3、常用压力单位转换环境条件1、室内环境条件在(20±5)℃下进行2、检定时应无影响计量性能的机械震动;3、室内的相对湿度45%~75%;4、工作介质:(0~-100Kpa)(0~40Kpa)(0~250Kpa)三个压力模块为空气(0~1Mpa),(0~2.5Mpa),(0~20Mpa)三个压力模块为变压器油。

五、工作原理康斯特CST2002智能数字压力校验仪以外接的压力模块为标准,以空气或变压器油作为传压介质,采用快速连接装置,可将各种被检表十分快速地连接到校验仪上,通过外接的手压泵或液体压力计给予压力。

被测压力经传压介质作用于压力模块上,压力传感器输出相应的电信号或数字信号,由信号处理单元处理后在显示器上直接显示出被测压力的量值。

由于本身精度较高通过比对法检定被检表。

六、仪器操作步骤1、开机,如发现电量不足,插上专用充电器;2、将被校仪表与压力计(手压泵或液体压力计)连接,确保被检表内部清洁。

根据被检表量程选择压力模块,如果要使用真空,选(0~-100Kpa)压力模块与手压泵连接,在把手压泵后面的承压管从正压端换到负压端。

压力模块与校验仪连接要用专用电线。

3、如果要给差压变送器供24V直流电测4-20mA输出,用一根专用测试线一端插入仪器的24V插孔,一端连接差压变送器的正极。

ecs-20温控器说明书

ecs-20温控器说明书

ecs-20温控器说明书一、产品简介ECS-20温控器是一款高性能的温度控制器,适用于各种工业、商业和家庭环境。

本产品采用先进的微处理器控制系统,具有高精度、高稳定性、易于操作等特点。

它可以广泛应用于制冷、加热、通风、空调等系统,实现对温度、湿度、风速等参数的精准控制。

二、产品特点1.高精度:ECS-20温控器具有±0.1℃的温度测量精度,满足各类场景对温度控制的需求。

2.高稳定性:本产品采用数字化校准技术,确保长时间运行过程中的稳定性。

3.操作简便:触摸屏设计,使操作更加便捷、直观。

4.多种输入方式:支持温度、湿度、压力等多种信号输入,满足多种控制需求。

5.具备通讯功能:支持RS485/RS232通讯接口,便于与上位机或其他设备连接。

三、产品功能1.温度控制:设置目标温度,实现对设备的自动开启、关闭和调节。

2.温湿度控制:集成湿度控制功能,实现对环境的温湿度调节。

3.定时功能:支持定时开关机,满足特定场景的使用需求。

4.报警功能:超温、欠温、故障等异常情况下,及时发出警报。

5.数据记录:实时记录温度、湿度等参数,便于后期分析和查看。

四、产品安装与使用方法1.安装:根据设备尺寸和接线要求,进行合理安装。

2.接线:连接电源线、信号线和控制线,注意接线正确无误。

3.调试:通过触摸屏进行参数设置,调整至所需控制模式。

4.使用:启动设备,观察温度控制效果,如有异常,及时调整。

五、产品维护与保养1.定期清洁:清除控制器表面灰尘,保持设备清洁。

2.检查线路:定期检查接线、电缆等,确保连接良好。

3.更换零部件:根据使用年限和磨损情况,更换零部件。

六、产品安全注意事项1.安装时,确保电源线完好无损,防止触电事故。

2.接线过程中,切勿带电操作,以免发生意外。

3.使用过程中,注意观察设备运行状况,发现异常立即停机检查。

七、产品故障处理1.故障排查:根据说明书,逐步排查故障原因。

2.故障处理:根据实际情况,采取相应措施解决问题。

中文操作手册 - CS-iTEC·S020 温度变送器说明书

中文操作手册 - CS-iTEC·S020 温度变送器说明书

中文操作手册S020温度变送器尊敬的客户,感谢您选择我们的产品。

用户须在启动设备前完整阅读该操作手册并认真遵守。

对于因未仔细查看或者未遵守此操作手册规定而造成的任何损失,制造商概不负责。

如果用户违反此操作手册所描述或规定的方式,擅自改动设备,仪器保修将自动失效并且制造商免除责任。

请按照此操作手册说明的专业用途使用该设备。

对于该设备在未描述用途上的适用性,希尔思公司不做任何保证。

由于运输、设备性能或使用造成的间接损失,希尔思公司不承担责任。

目录1 安全说明 (4)2 注册商标声明 (5)3 应用 (6)4 特点 (6)5 技术参数 (6)5.1 常规 (6)5.2 电气参数 (6)5.3 信号输出 (6)5.4 精度 (7)6 尺寸图 (7)7 确定安装点 (7)8 安装 (8)8.1 安装要求 (8)8.2 安装步骤 (8)8.3 电气连接 (9)9 信号输出 (10)10 可选配件 (10)10.1 压合配件 (10)11 校准 (10)12 维护 (10)13 废弃物处置 (10)1 安全说明1 安全说明请检查此操作手册和产品类型是否匹配。

请查看此手册中包含的所有备注和说明。

手册中包含了前期准备和安装、操作及维护各个阶段需要查看的重要信息。

因此技术人员以及设备负责人或授权人员必须仔细阅读此操作说明。

请将此操作手册放置在操作现场便于取阅的地方。

针对此操作手册或者产品有任何不明白或疑惑的地方,请联系制造商。

警告!压缩空气!任何与急速漏气或压缩空气系统带压部分的接触都有可能导致重大损伤甚至死亡!•不要超过允许的压力范围(请查看传感器标签)。

•只使用耐压的安装材料。

•避免人员接触急速的漏气或仪器带压的部分。

•进行维修维护作业时必须确保系统没有压力。

警告!电源电压!任何与产品通电部分的接触都有可能导致重大损伤甚至死亡!•考虑所有电气安装相关的规定。

•进行维修维护作业时必须断开任何电源连接。

•系统中任何电气工作只允许授权人员进行操作。

过程控制与自动化仪表(第3版) 第2章 思考题与习题

过程控制与自动化仪表(第3版) 第2章 思考题与习题

第2章 思考题与习题1.基本练习题(1)简述过程参数检测在过程控制中的重要意义以及传感器的基本构成。

答:1)过程控制通常是对生产过程中的温度、压力、流量、成分等工艺参数进行控制,使其保持为定值或按一定规律变化,以确保产品质量的生产安全,并使生产过程按最优化目标进行。

要想对过程参数实行有效的控制,首先要对他们进行有效的检测,而如何实现有效的检测,则是有检测仪表来完成。

检测仪表是过程控制系统的重要组成部分,系统的控制精度首先取决与检测仪表的精度。

检测仪表的基本特性和各项性能指标又是衡量检测精度的基本要素。

2)传感器的基本构成:通常是由敏感元件、转换元件、电源及信号调理/转换电路组成。

(2)真值是如何定义的?误差有哪些表现形式?各自的意义是什么?仪表的精度与哪种误差直接有关?答:1)真值指被测物理量的真实(或客观)取值。

2)误差的各表现形式和意义为:最大绝对误差:绝对误差是指仪表的实测示值x 与真值a x 的差值,记为Δ,如式(2‐1)所示:a Δx x =- (2-1)相对误差:相对误差一般用百分数给出,记为δ,如式(2‐2)所示:aΔδ100%x =⨯(2-2) 引用误差:引用误差是仪表中通用的一种误差表示方法。

它是相对仪表满量程的一种误差,一般也用百分数表示,记为γ,如式(2‐3)所示:max minΔγ100%x x =⨯- (2-3)式中,max x 仪表测量范围的上限值;min x 仪表测量范围的下限值。

基本误差:基本误差是指仪表在国家规定的标准条件下使用时所出现的误差。

附加误差 附加误差是指仪表的使用条件偏离了规定的标准条件所出现的误差。

3) 仪表的精度与最大引用误差直接有关。

(3)某台测温仪表测量的上下限为500℃~1000℃,它的最大绝对误差为±2℃,试确定该仪表的精度等级;答:根据题意可知:最大绝对误差为±2℃则精度等级%4.0%1005002±=⨯±=δ所以仪表精度等级为0.4级(4)某台测温仪表测量的上下限为100℃~1000℃,工艺要求该仪表指示值的误差不得超过±2℃,应选精度等级为多少的仪表才能满足工艺要求?答:由题可得:仪表精度等级至少为0.001级。

NHR-M22系列温度变送器

NHR-M22系列温度变送器

版本号:M22-160112
NHR-M22系列温度变送器
使用说明书
产品介绍
NHR-M22系列温度变送器将现场的热电阻或热电偶信号经过隔离放大处理,转换为与温度成线性的直流信号输出至控制系统,用作热电偶温度变送时,具有冷端温度自动补偿功能。

可用配套的上位机软件进行参数修改,可以与单元组合仪表及DCS、PLC等系统配套使用,给予现场仪表信号隔离、信号转换、信号分配、信号处理等,从而提高工业生产过程自动控制系统的抗干扰能力,保证系统的稳定性和可靠性。

本产品品种分为一进一出、一进二出、二进二出,且输入、输出磁隔离。

1 显示面板外观结构图
EVT:断线指示灯,信号存在断线、超上限、超下限时,指示灯红色;信号正常时灯不亮。

PWR:电源指示灯为绿色。

35mm导轨式安装,安装时请注意卡位稳定、牢固,请尽可能垂直安装,以利于仪表内部热量散发。

2 选型表
4 接线图。

X20(c)AT6402 温度传感器模块说明书

X20(c)AT6402 温度传感器模块说明书

X20(c)AT64021 General informationThe module is equipped with 6 inputs for J, K, N, S, B and R thermocouple sensors. The module has an integrated terminal temperature compensation.•6 inputs for thermocouples•For sensor types J, K, N, S, B, R•Additional direct raw value measurement•Integrated terminal temperature compensation•Configurable filter time2 Coated modulesCoated modules are X20 modules with a protective coating for the electronics component. This coating protects X20c modules from condensation and corrosive gases.The modules' electronics are fully compatible with the corresponding X20 modules.For simplification purposes, only images and module IDs of uncoated modules are used in this data sheet.The coating has been certified according to the following standards:•Condensation: BMW GS 95011-4, 2x 1 cycle•Corrosive gas: EN 60068-2-60, Method 4, Exposure 21 days3 Order dataTable 1: X20AT6402, X20cAT6402 - Order data4 Technical dataTable 2: X20AT6402, X20cAT6402 - Technical dataTable 2: X20AT6402, X20cAT6402 - Technical data 1)Ta min.: 0°CTa max.: See environmental conditions2)Based on the entire measurement range without consideration of the cold junction measurement error3)Based on the current measured value.4)Based on the entire measurement range.5 LED status indicatorsFor a description of the various operating modes, see the section "re LEDs" in chapter 2 "System characteristics"of the X20 system user's manual.6 Pinout1X 20 A T 640223456r e 7 Connection exampleAT8 Input circuit diagram9 Ceramic heating element with integrated thermo elementsWe recommend connecting the minus input of the thermo element to the minus input of the supply feed module. This prevents potential measurement errors caused by ripple voltage effects in the measurement signal.10 External cold junctionGeneral informationAn external cold junction temperature value can be predefined for the module for measurement value correction. This makes it possible to set up an external cold junction. The same external cold junction temperature is used for measurement value correction on all channels.An external cold junction makes sense in the following applications and situations:•Large distances between the controller and measurement point•To increase precisionTo bridge large distancesSetting up an external cold junction is recommended when there are large distances between the controller and the measurement point. The thermocouple voltage is routed from the external cold junction to the terminal on the X20AT6402 via copper wires. The temperature measured at the external cold junction (e.g. with PT100 -X20AT4222) is stored in the I/O area of the X20AT6402 module. The X20AT6402 uses the measured voltage andthe cold junction temperature to internally calculate the needed thermocouple temperature.Increased precisionSetting up an external cold junction is recommended to increase precision. The external cold junction is set up asdescribed above. The installation of an external cold junction is especially helpful in the following cases:•A module consuming more power than 1 W is connected in addition to the X20AT6402.•No modules but the X20AT6402 are connected•With strongly fluctuating ambient conditions (draft, temperature)11 Register description11.1 General data pointsIn addition to the registers listed in the register description, the module also has other more general data points. These registers are not specific to the module but contain general information such as serial number and hardware version.These general data points are listed in the "General data points" section of chapter 4 "X20 system modules" in the X20 system user's manual.11.2 Function model 0 - default11.3 Function model 1 - External cold junction temperature11.4 Function model 254 - Bus controller1)The offset specifies the position of the register within the CAN object.11.5 General information11.5.1 Raw value measurementIf a sensor type other than J, K, N, S, B or R is used, the terminal temperature must be measured on at least one input. Based on this value, the user must then implement terminal temperature compensation.11.5.2 TimingThe timing for acquiring measurement values is determined by the converter hardware. All enabled inputs are converted during each conversion cycle. In addition, the terminal temperature is measured (not in function model 1). Any inputs that are not needed can be switched off, which reduces the I/O update time. Inputs can also be only switched off temporarily. Measuring the terminal temperature is switched off in function model 1.11.5.3 Conversion timeThe conversion time depends on the number of channels and the function model. For the formulas listed in the table, "n" corresponds to the number of channels that are switched on.ExamplesInputs are filtered using a 50 Hz filter.11.6 Configuration11.6.1 Input filter and ambient conditionsName:ConfigOutput01This register configures input filters and ambient conditions.Input filterThe filter time for all analog inputs is defined using the input filter parameter.Environmental conditionsAmbient conditions are set in order to adjust the internal terminal temperature characteristic curve to the type and amount of generated heat dissipated to the module.This selection is based on the power consumption of the modules connected immediately to the left and right on the X2X Link. Power consumption values can also be found in the technical data for the corresponding module. The higher value is used for the configuration.Bit structure:11.6.2 Sensor typeName:ConfigOutput02This module is designed for a wide range of sensor types. The sensor type must be configured because of the different alignment values.11.6.3 Channel disablingName:ConfigOutput03By default, all channels are switched on. To save time, individual channels can be switched off (see "Conversion time" on page 8).Bit structure:X20(c)AT6402 11.7 Communication11.7.1 Analog inputsName:Temperature01 to Temperature06Analog input value depending on the configured sensor type:In order for the user to always be supplied with a defined output value, the following must be taken into consid-eration:•Up to the first conversion, 0x8000 is output.•After switching the sensor type, 0x8000 is output until the first conversion.•If the input is not switched on, 0x8000 is output.11.7.2 I/O cycle counterName:IOCycleCounterThe cyclic counter increases after all input data has been updated.11.7.3 Input statusThe module's inputs are monitored. A change in the monitoring status generates an error message.In addition to the status info, the error type also sets the analog value as follows:11.7.3.1 Status of inputs 1 to 4Name:StatusInput01Bit structure:X20(c)AT640211.7.3.2 Status of inputs 5 to 6Name:StatusInput02Bit structure:11.7.4 Reads the internal cold junction temperatureName:CompensationTemperatureThe internal cold junction temperature is stored in this register.11.7.5 Defines the external cold junction temperatureName:ExternalCompensationTemperatureThe external cold junction temperature is defined in this register.11.8 Minimum cycle timeThe minimum cycle time defines how far the bus cycle can be reduced without communication errors occurring. It should be noted that very fast cycles decrease the idle time available for handling monitoring, diagnostics and acyclic commands.11.9 Minimum I/O update timeThe minimum I/O update time defines how far the bus cycle can be reduced while still allowing an I/O update to take place in each cycle.For the formulas listed in the table, 'n' corresponds to the number of channels that are switched on.。

智能温度变送器一入一出24VDC供电

智能温度变送器一入一出24VDC供电

智能温度变送器(一入一出、24V DC供电)产品概述本智能温度变送器采用16位专用集成芯片设计,采集现场各种热电阻、热电偶等一次传感器的信号,经过放大、运算、隔离、抗干扰抑制等处理后,向控制系统或其它智能仪表输出直流电流或电压信号。

本智能配电器采用输入、输出、电源三端隔离技术,绝对电气隔离,断开过程环路中的直接电路(直流通路),使得检测和控制回路信号的稳定性和抗干扰能力大大增强,从而提高了整个系统的可靠性。

产品特点◆全智能、数字化、现场可编程◆ 16位高精度采集芯片设计◆测量分段线性化处理◆输入故障状态指示◆ 12.7mm超薄厚度,便于密集安装◆标准DIN35mm导轨安装技术参数◆传输精度:±0.2%F〃S (25℃±2℃)◆温度漂移:≤50ppm/℃(-20~+60℃)◆冷端补偿:±1℃(预热时间10分钟;热电偶有效)◆引线电阻:≤20Ω(热电阻有效)◆负载能力:电流≤500Ω;电压≥1MΩ◆响应时间:≤2 S◆介电强度:≥1500V AC(输入/输出/电源之间,漏电流1mA,测试时间1min)◆电磁兼容:符合IEC61000-4-4:1995中第三类工业现场对抗电磁干扰的要求◆供电电源: 20~30V DC◆功耗: 0.65W(24V供电,1路满载输出);◆工作温度: -20~+60℃输入信号○热电偶:K(0-1300℃); E(0-900℃); S(0-1600℃); B(300-1800℃);J(0-1200℃); R(0-1600℃); N(0-1300℃); T(0-400℃);Wre3-Wre25(0-2300℃); Wre5-Wre26(0-2300℃)○热电阻:Pt100(-199-600℃); Cu100(-50-150℃); Cu50(-50-150℃);BA1(-199-600℃); BA2(-199-600℃); Pt1000(-199-600℃);○其它输入、输出类型可特殊订制输出信号○ 4-20mA ○ 0-10mA ○ 0-20mA ○ 1-5V ○ 0-5V ○ 0-10V面板说明PWR :电源指示灯(绿色);工作时常亮。

ws905022温度变送器说明书

ws905022温度变送器说明书

ws905022温度变送器说明书
一体化温度变送器,是较为小巧的圆形的那种温度变送器,该产品是与铠装的温度变送器一体安装的,所以又称为一体化温度变送器。

该变送器是将前级有分度的热电阻或者热电偶等信号转换为标准的二线制4-20mA信号的产品,输出信号回路需要后级提供24V供电,信号的转换没有经过隔离,转换精度为0.5%。

热电阻温度变送器更换,如果温度变送器量程包含您热电阻的标定范围的话就不需要更换。

比如:现用热电阻:-200-450度,热电阻温度变送器温度范围是-200-850度,需要更换热电阻范围为:0-600度的,此时热电阻温度变送器的温度范围包含需要更换的热电阻的温度范围,就不需要更换温度变送器的,温度变送器一进二出,原有的后级仪表设置的温度范围也不需要更换的。

热电阻输入信号隔离模块,WS90501,PT1000-200度输入,4-20mA输出,供电DC24V,一进一出等同型号TSP-TR1P11/0-200,WS90502,PT1000-200度输入,4-20mA输出,供电DC24V,温度变送器WS9050,一进二出等同型号TSP-TR2P11/0-200,WS905022,PT1000-200度输入,温度变送器,4-20mA输出,供电DC24V,二进二出等同型号TSP-TR5P11/0-200。

热电阻信号转模拟量电流电压信号,三端隔离,滤除干扰。

温度变送器通用技术规范

温度变送器通用技术规范
4.3本产品面板字迹应清晰,各操作键接触良好,现场调节方便。
4.4产品标志:测试仪上应有铭牌,铭牌上应有下列标志:
厂名,厂址;
2)产品的名称,型号;
3)制造日期;
4)出厂编号;
5验收及技术培训
5.1 交货后供方须派技术人员指导用户进行安装使用,以验证产品性能。
5.2 卖方应负责对买方进行培训,并提供相应的培训资料。
1.1.6本采购标准规范将作为订货合同的附件,与合同具有同等的法律效力。本采购标准规范未尽事宜,由合同签约双方在合同谈判时协商确定。
1.1.7本采购标准规范中涉及有关商务方面的内容,如与招标文件的商务部分有矛盾时,以商务部分为准。
1.1.8本招标文件采购标准规范中通用部分各条款如与采购标准规范专用部分有冲突,以专用部分为准。
6、投标人应逐项响应技术规范专用部分中相应内容。填写投标人响应部分,应严格按技术规范专用部分的“招标人要求值”一栏填写相应的投标人响应部分的表格。投标人填写技术参数和性能要求响应表时,如有偏差除填写“投标人技术偏差表”外,必要时应提供相应试验报告。
7、货物需求一览表中数量各项目单位和设计院必须填写,如不能确定准确数量,可以填写估算数量。
1.6
1.6.1每个投标人应提供1.2中要求的技术资料和技术数据,投标人提供的技术数据应为产品的性能保证数据,这些数据将作为合同的一部分,任何与这些数据的偏差都应经过买方的同意。
1.6.2卖方提供温度变送器的特性参数和其他需要提供的信息。
1.6.3卖方提供温度变送器使用单位的使用报告。
2
2.1温度变送器体积小、重量轻,安装使用方便。
(5)投标人应提供生产计划进度表。
(6)投标人应提供同种产品的月生产能力。
(7)按附录B填写仪器配置表。

SCT2002 智能温度报警控制器操作手册

SCT2002 智能温度报警控制器操作手册

SCT2002 智能温度报警控制器操作手册概况SCT2002 采用最新式进口数字传感器,精度高,抗腐蚀,寿命长,范围宽,性能好,能在各种环境下长期稳定可靠工作。

自带RS232 方式接口,可与电脑或工控设备进行通讯。

技术参数显示分辨率0.1℃测温精度0.5℃测温范围-55-125℃继电带载能力5A 250V(阻性负载)波特率9600 (可订制其它波特率)通讯端口RS232(可选配CAN、RS485 或以太网)机械寿命最少3000,000 次工作电压AC 85-265V耗电2W重量210 克存储温度-20 ~80℃运行环境:-40℃~+85℃支持测温电缆长度小于140m(可定制长距离500m)外形尺寸72×72×111mm安装方式面板式面板尺寸72mm×72mm 开孔尺寸67.5×67.5特点采用进口高性能,高精度,抗腐蚀,长寿命,高可靠性的全数字温度传感器,范围宽,线性度好,能长期在各种环境下稳定可靠的工作. 实时数显温度,集多种功能于一体,方便用户不同场合使用。

传感器用3 根导线进行温度信号传输,标准仪表的传感器和仪表间长度小于140m,也可定制500m 长度,长距离布线建议用0.75 平方以上线缆。

用途适用于室内外温度检测、报警、控制,定做防水总线可长时间检测水下温度。

可以通过232 接口和电脑、PLC 等采集控制设备联机,传输温度数据。

广泛用于粮库、仓库、养殖、纺织业等需要温度检测报警的场合。

仪表安装方法仪表为嵌入式方形安装,安装时将仪表从正面推入开好孔的柜体面板上,开孔尺寸应为(67.5mmX67.5mm),然后把支架从仪表的后面把仪表用螺丝旋紧,顶至不活动。

按接线图将传感器对颜色接至仪表(仪表后面接线端必须与传感器路数输入相对应,与传感器接线端子1-4 脚按相应的次序连接)确认接线无误后,即可通电,通电后按照操作说明操作即刻显示测得的温度值。

建议使用前仔细阅读说明文档,熟练操作后安装。

配电自动化专业知识技能竞赛题库汇总(二)

配电自动化专业知识技能竞赛题库汇总(二)

配电自动化专业知识技能竞赛题库汇总(二)在配电自动化通信方式中,属于串口通信方式的为()。

A、配电载波B、GPRS C、GSM D、RS-232 答案:D 解析:《配电自动化专业技能题库》数据通信系统的传输方式,按照信息传输的方向和时间可分为()()A、单工通信B、半双工通信C、全双工通信D、以上三项都是答案:D 解析:配电自动化运维技术P126心跳测试过程中配电主站发送功能码“发送/确认()链路测试功能”,配电终端回复“认可确认”()。

A、FC=1;FC=0 B、FC=2;FC=1 C、FC=2;FC=0 D、FC=3;FC=0 答案:C 解析:运检三〔2017〕6号国网运检部关于做好“十三五”配电自动化建设应用工作的通知(1)正文150页下列传输介质中不受电磁干扰的是()A、双绞线B、同轴电缆C、光纤D、音频电缆答案:C 解析:配电自动化运维技术P149104规约采用()方式传输。

A、非平衡方式传输B、平衡方式传输C、都是D、都不是答案:B 解析:6-配电自动化系统应用DLT634.5104-2009实施细则(试行)104规约默认采用端口()A、2404 B、10001 C、10002 D、1024 答案:A 解析:6-配电自动化系统应用DLT634.5104-2009实施细则(试行)报文格式的控制域定义中,编号的监视功能格式简称()A、I-格式B、S-格式C、U-格式D、都不是答案:B 解析:6-配电自动化系统应用DLT634.5104-2009实施细则(试行)报文格式的控制域定义中,编号的信息传输格式简称()A、I-格式B、S-格式C、U-格式D、都不是答案:A 解析:6-配电自动化系统应用DLT634.5104-2009实施细则(试行)报文格式的控制域定义中,不编号的控制功能格式()简称A、I-格式B、S-格式C、U-格式D、都不是答案:C 解析:6-配电自动化系统应用DLT634.5104-2009实施细则(试行)当配电通信系统发生异常时,应通知()人员并按照缺陷处理要求时限及时处理。

SHT102-2023

SHT102-2023

SHT102-2023概述SHT102-2023是一种新型智能温湿度传感器,广泛应用于环境监测、气象观测、室内空调系统等领域。

该传感器具有高精度、快速响应、稳定性好等特点,能够提供准确的温湿度数据,为用户提供可靠的环境信息参考。

技术规格•工作电压:3.3V-5V•测量范围:–温度:-40°C至80°C–湿度:0%RH至100%RH•精度:–温度:±0.3°C–湿度:±2%RH•长期稳定性:温度<0.03°C/年,湿度<0.25%RH/年•响应时间:–温度:8秒–湿度:5秒•通信接口:I2C功能特点高精度测量SHT102-2023采用先进的温湿度传感器技术,具有高精度的测量能力。

温度测量精度可以达到±0.3°C,湿度测量精度可以达到±2%RH,能够满足各种应用场景的需求。

快速响应SHT102-2023具有快速响应的特点,能够在8秒内完成温度测量,5秒内完成湿度测量。

这种快速响应的特性使得该传感器可广泛应用于要求实时性较高的系统中,如气象监测、工业自动化等。

长期稳定性SHT102-2023具有优异的长期稳定性,温度长期稳定性小于0.03°C/年,湿度长期稳定性小于0.25%RH/年。

这意味着在长时间使用过程中,传感器能够保持较高的测量精度,不需要频繁的校准。

简易接口SHT102-2023采用标准的I2C通信接口,方便与主控设备进行连接。

通过简单的通信协议,用户可以轻松地获取传感器测量到的温湿度数据,并进行相应的处理与分析。

应用领域环境监测由于SHT102-2023具有高精度和快速响应的特点,广泛应用于环境监测领域。

比如空气质量监测、温湿度变化监测等。

通过对环境温湿度的实时监测,可以帮助用户及时发现异常情况,采取相应的措施。

气象观测SHT102-2023的高精度和长期稳定性使其成为理想的气象观测设备。

FST600-202 一体式温度变送器产品说明书

FST600-202 一体式温度变送器产品说明书

一体式温度变送器产品说明书(V1.0)湖南菲尔斯特传感器有限公司Hunan Firstrate Sensor Co.,Ltd●重要声明非常感谢您购买菲尔斯特传感器(变送器),我们为您真诚服务到永远。

菲尔斯特追求卓越不凡的品质,更注重良好的售后服务,如有问题,请拔打:400-607-8500(7×24h)。

操作错误会缩短产品的寿命,降低其性能,严重时可能引起意外事故。

请您在使用前务必仔细熟读本说明书。

将本说明书交到最终用户手中。

请妥善保管好说明书,以备需要时查阅。

说明书供参考所用,具体设计外形以实物为准。

●产品概述本公司生产的工业通用温度传感器是由热电阻(偶)与防护金属外壳组合而成,温度变送器是在传感器基础上增加变送转换功能,采用二、三线制信号输出方式,带有非线性校正电路,可直接测量工业过程中的液体、气体介质,安装简单,多种测温范围可选;●性能特点1、安装简单,多种测温范围可选;2、高效防雷击、强抗射频和电磁干扰保护;3、反应速度快、精确度度高;4、长期稳定性好、低能耗、体积小;5、气液两用,与316L兼容的任何介质;●技术指标●电气接口及接线方法●注意事项1、安装时请注意安装方式,安装是否匹配,扳手只可套接在六方接口处进行安装,严禁套在产品外管及尾接头处安装;2、使用时注意线路连接可靠,连线方式正确,产品电缆线请勿用力拉扯,以免损坏产品内部结构;3、严禁产品超量程使用,产品出现异常,请停机检查;4、传感(变送)器的运输、安装、使用过程中不可随意摔放,避免损坏;5、产品保修期为一年,非用户使用不当造成的损坏保修包换;6、传感(变送)器应存放在通风良好、无酸、无碱、无腐蚀性气体的库房,环境温度-20℃~+60℃,相对湿度小于95%RH。

湖南菲尔斯特传感器有限公司Hunan Firstrate Sensor Co.,LtdA:湖南省长沙市雨花经开区智能制造产业园振华路智庭园1栋T:+86-731-86905666W:F:+86-731-86205777E:*****************P:410000400-607-8500。

智能温度变送器中文版

智能温度变送器中文版

☞ 性能简介输入热电偶/热电阻信号,经隔离转换为电流/电压信号输出。

输入端、输出端及电源端三端隔离,具有在线故障自诊断等功能,是智能化的温度变送器产品。

可选配本公司专用的手持式编程器修改参数或校准(详见《编程器使用说明》)。

☞ 技术参数□ 输入信号类型:热电偶:K 、E 、S 、B 、J 、T 、R 、N 及WRe3-WRe25、WRe5-WRe26等;热电阻:二/三线制热电阻(Pt100、Cu50、Cu100、BA1、BA2等);输入信号类型及量程在订货时确定,也可自行编程。

□ 输出信号类型:直流电流:0(4)mA ~20mA ; 0mA ~10mA;直流电压:0(1)V ~5V ;0V ~10V;如需其它信号类型请订制,具体信号类型详见产品标签。

□ 输出纹波:<5mV rms (负载250Ω)□ 隔离传输准确度(25℃±2℃,不含冷端补偿): 输入信号类型量程范围 准确度 TCK/E/J/N 等< 300 ℃ ±0.3 ℃ ≥ 300 ℃ ±0.1% F∙S S/B/T/R/WRe-系列< 500 ℃ ±0.5 ℃ ≥ 500 ℃ ±0.1% F∙S RTDPt100/Cu100/Cu50/BA1/BA2等< 100 ℃ ±0.1 ℃ ≥ 100 ℃±0.1% F∙S□ 温度漂移:40ppm/℃□ 冷端温度补偿准确度:±1℃(预热时间10分钟) □ 冷端温度补偿范围:-20℃~+60℃ □ 测量热电阻允许的引线电阻:≤20Ω/线 □负载能力:0(4)mA ~20mA :≤550Ω;0mA ~10mA: ≤1.1k Ω 0(1)V ~5V :≥1M Ω; 0V ~10V :≥2M Ω; □ 满载功耗:24V DC 供电,单路满载输出时 0.7W24V DC 供电,双路满载输出时 1.3W□供电电压范围:18V DC ~32V DC (典型值:24V DC )□ 介电强度(漏电流1mA ,测试时间1分钟): ≥2500 V AC (输入/输出、输入/电源之间) ≥1500 V AC (输出/电源之间)□ 绝缘电阻:≥100M Ω(输入/输出/电源之间) □电磁兼容:EMC 符合IEC61326—3☞ 输出状态□ 跟随方式:在用户不特别指明的情况下,无论输入信号出现何种故障状态(断线除外,断线输出0 V/mA),在满量程范围内输出均跟随输入信号变化,但最大不超出输出量程上限的110% (如0mA ~20mA 输出时,最小输出可为0mA ,最大不超过22mA)。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

SC228、SC222、SC220、SC22L ,是在不改变具有优良互换性特征的热电阻、热电偶等测温
元件的前提下,对传统的智能化技术方法,进行了重大革新的新型超准测温仪器。

当配置 A 级
Pt100 时,包含互换误差在内,这些仪器可实现高达或的测温准确度。

这些测温仪器,经人机界面,同时向用户开放,由帅克 SUCCESS 科研小组原创,目前世界上的线性拟合校准软件;当仪器用户,采用恒温源校准标定仪器时,在全量程范围内,仅需恒温 
5~10 
个左右的校准点,软件就能将全域测温误差,校正到±0.04℃+恒温源准确

之内。

SC220 ,是一款无显示屏的微型化、全数字化、抗振动、防水型智能变送器,它有别于国内外其它品牌一体化智能温度变送器的独创性在于:
①、 校调校准,不需开盖,也不需要接入手操器等外部设备——防水外壳上有两个按键,可分别用来计量校准变送 器的零点和满度;当将温度探头,置于 0 ℃恒温水浴时,同时按下两 个键,可直接消除零位偏移 ②、卓越的状态自诊断,自校准能力
SC222 ,是一款带有高亮液晶显示屏的多功能智能变送器,它的独创性在于:
①、具有超强大的数字滤波能力,扫描宽深可根据需要自由定义,能轻松平滑压制住任意强度的干扰
②、支持从小到大,或者从大到小,任意跨度的量程无源迁移;例如,对于一台测量范围 -50~600℃ 的变送 器, 你可以将 4~20mA 信号的变送范围,设为 -50~600℃、300~-100℃ 、200~300℃,等等,也就是说,你不需 要添加任何的信号转换装置,就可以获得,信号方向和控制方向匹配,信号强度和驱动设备 强度匹配的信号, 直接实现正作用控制或者反作用控制;恰当地设置变送范围,既能采用低识别率的信号接受装置,完成高精度 控制任务,还能使设备运行于最佳状态,实现最大节能、最高效率等目标 ③、卓越的状态自诊断、自校准 能力
SC22L ,是在 SC222 基本测量功能基础上,扩展了输出信号的定格保持功能,当触键启动
该功能时,输出信号可根据需要,定格保持在某个“安全”值上,例如 4mA、5mA 、18mA等,而不再与过程温度,有对应关系;这样一些需要中断控温的工艺过程,例如高温蒸汽消毒过程等,由于变送器的输出信号保持不变,那么在不断电的情况下,便不会造成变送器的后级控制设备,误动作误报警;在工厂,过程中断往往需要繁杂的生产调度来协调后级的各个动力设备,稍有不甚就会出错;而启动 SC22L 
的输出信号定格保持功能后,则不再需要对变送器后级设备进行任何干预,这既能显著地提高系统运行的安全性,又能为工厂节省大量的生产管理成本。

SC228 ,是一款可对两路温度的差值,进行任意跨度、正反双向信号远传变送的智能变送器,即 
4~20mA 信号对应的温差范围,既可设置成
0.00℃~5.00℃,也可设置成 
5.00℃~0.00℃8.00℃~-3.00℃ ,等等,这一特点,使其成为空气调节等温差控制系统的理想元件。

上述产品的其它特点有:
① 提供一体化整体防水封装、感温探头可互换快插防水封装 、感温探头可互换带缆快插防水封装 、 分体盘装封装
多种结构温度探头供选,如:拧装式、 法兰式 、刺入式、 投入式、 手持式……
② 挑战极限的Φ75mm X 45mm 超微型铝合金屏蔽外壳 
匠心独具的防振、防爆、防湿气、防水淋、防过旋、双轴旋转外壳设计
0 0 360可旋转表盘 (X 轴),360可旋 转表壳(Y 轴),任意角度、任意方向安装,都不影响数据观测;并可直接 在汽车、飞行器等振动设备上安装使用
③ 卓越抗电磁干扰能力;5 位数值显示 ,灵敏稳定看得见;当不需要观测 5 位数值时,触键可直接减少显示位数; 支持单通道单显、双通道循显、三通道循显
典 型 应 用
±0.3℃±0.4% 
读数最先进、最高效通空调 烤漆
房 锅炉炉膛 供暖管道 精密仪器 航空航海试验装置
陕西帅克传感仪器制造有限公司 www.sc-sensor.com
概述
■SC228 数显多功能超准双路温差变送器SC222 数显多功能超准温度变送器SC22L 信号保持超准温度变送器SC220 超准智能温度变送器
( 量程:-200~50℃ 
・・・ 0~2300℃ )感仪器 制仪器
传 控
陕西帅克传感仪器制造有限公司 www.sc-sensor.com
性 能 参 数测温范围:-200~2300℃ [ 详见“标准量程范围选型表”] 
测温准确度等级:采用热电阻元件时,包括互换误差在内,≤±0.4%rdg 或者≤±0.3℃( 取两者中值大者 ) 采用热电偶元件时,≤±0.2%FS 关于准确度的说明:
1、rdg 表示测量读数值 ;FS 表示满量程值
2、准确度指仪器测量值与标准值的绝对误差,包括 非线性、迟滞、非重复性、零位漂移、灵敏度漂移
3、测试条件:无影响测量稳定性的振动和电磁干扰; 铝合金壳体内电路部分处于温度 20±2℃,温度波动≤1℃;气压 86~106 kPa; 湿度 45%RH~75%RH 的环境下
测温分辨率:五个有效位,对热电阻为 0.01℃或 0.02℃,对热电偶为0.1℃;测值和单位同屏显示 变送输出信号的准确度等级:≤±0.05%FS 采样速率:>6000 
次/秒信号刷新速率:2~5 
次/秒
电路部分使用温度:液晶显示屏为-20~65℃,其余部分为-40~85℃其它功能:详见“概述”部分
0℃的稳定性:①当温度探头工作于 -50℃~400℃之间连续 6000 小时后,回温至 0℃, 0℃漂移量≤0.3℃ ②当温度探头工作于 -50℃以下或者 400℃以上连续 6000小时后,回温至 0℃, 0℃漂移量≤0.6℃灵敏度的稳定性:≤0.2℃/年或≤0.05% 
最高工作温度/年 ,取大者
电 气 参 数
供电电源:24VDC(配置无背光液晶屏时为 10~30V,配置背光液晶屏时为 12~30V)电流负载:< 50×(U-10)Ω 【U:电源电压】 
输出信号:闪速 D/A 转换,两线 4~20mA 、三线 0~5V 等(详见“输出格式选型表”)
校准:通过直接触键或人机界面校准;重新标校时,通常仅需标校传感器的低点和高点 两个点(例如0℃和 200℃),就能恢复产品出厂时的准确度;当采用精密温度源校准时,可通过线性拟合校准软件,将 线性误差,修调到±0.04℃以内
防爆标志:本安防爆,防爆型产品 ExiaⅡCT6(详见“防爆要求选型表”)国家防爆电气产品认证编号:CNEx
绝缘电阻和绝缘强度:> 500MΩ;耐压 500V 无击穿电源电压变化对输出的影响:< 0.003%FS/V
电气接口与电缆线径要求:HSM 防水连接器( 线径Φ4.5~Φ6.5mm ); HK 防水快速连接器( 线径Φ4.5~Φ6.5mm )
物 理 参 数
适用介质:与结构材料(探头材料、密封材料)不发生化学反应的液体和气体
探头基座材料:不锈钢 [321、316L、316、304L、304 等 ]、蒙耐尔合金、哈氏合金、钛及钛合金、聚四氟 乙烯、钽、铂金、陶瓷、刚玉等以及 SUCC-X 无国标牌号帅克特研耐腐蚀材料 [ 材料由温度使用范围及介质性质等因素决定 ]
探头密封材料:丁晴橡胶 氟橡胶、四氟乙烯、胶粘剂等 [ 密封材料通常仅限投入式温度探头 ]电气壳体材料:铝合金 防护等级: IP65、IP64
按键与显示屏: SC220为双按键,无显示屏;其它为 3 
按键;段式液晶屏,带单位,可选背光屏安装接口:详见“过程接口选型表”
整体重量:约 1~10kg[ 因应用亚型不同而有差异 ]
技术指标

陕西帅克传感仪器制造有限公司 www.sc-sensor.com外型尺寸

仪器.com
常见外型示意图
三线制 0.5 ~ 4.5V、1~5V、0~5V、0~10V 、4~20mA、0~10mA 电气连接示意图
两线制 4~20mA 输出信号电气连接示意图


电气连接
接变送器端子 1接变送器端子 2 导线电阻
记录仪
万用表
显示控制仪
电源
产品选型
■仪器型号 耐压性能 探头材料 探头类型 探头安装接口 探头插入深度 探头电气封装 现场显示 量程范围 准确度等级 输出信号 供电电源 防爆要求 电气接口 外壳类型 。