IBM DS8000微码升级步骤

IBM DS8000微码升级步骤

DS8000微码升级步骤1系统情况检查 (1)1.1运行end of call. (1)1.2检查当前微码版本,确定微码升级方式 (2)2数据备份及应急方法 (2)3停DS8000 COPY SERVICE服务 (2)3.1升级灾备中心DS8000前PPRC操作 (2)3.2升级生产中心DS8000前PPRC操作 (2)4微码升级 (3)4.1当前版本与目标版本 (3)4.2 code升级时间需求 (3)4.3升级顺序 (3)4.4升级步骤 (3)5 COPY SERVICE的恢复 (5)5.1升级灾备中心DS8000后PPRC操作 (5)5.2升级生产中心DS8000后PPRC操作 (5)1系统情况检查1.1运行end of call.检查是否有open call。

如存在问题需先行解决,再进行微码升级。

Run end of callFrom WebSM,Select: Service Applications1) Select: Service Focal Point2) Select: Service UtilitiesHighlight the SF: (2107-9xx---)Choose: “Selected” from the tool bar3)Select: View Storage Facility StateAll sections should report with passed in the status column.Failed status can be viewed by highlighting the System Check Type and thenselect details.4)If this is a multiple SF machine return to step A. above and check that SF’sresources.1.2检查当前微码版本,确定微码升级方式。

StorageManager管理软件客户端

StorageManager管理软件客户端

如何安装Storage Manager 客户端并调试IBM DS系列存储一、安装 Storage Manager 管理软件客户端当前IBM提供的最新Storage Manager版本为09.15(其实已经有更新的了在LSI网上有下载)。

这个版本采用了新的打包分发模式,安装与先前的版本有所不同,这里对客户端软件的安装进行介绍。

1 准备工作:1)一台台式机或者笔记本电脑;注明:用作客户端,从这台电脑上面管理DS4000产品;2)以太网线(如果有交换机的话)或者直连线(如果没有交换机的话)注明:线缆用作连接客户端和DS4000上面的以太网口3)配置客户端的ip地址和DS4000的IP地址在同一个网段(DS4000的默认的IP地址是:控制器A:192.168.128.101,控制器B:192.168.128.102;DS4800的控制器A主机端口2:192. 168.129.101,DS4800的控制器B主机端口2:192. 168 .129.102)进行”ping”的测试,确保连通;4)下载storage manager(58MB)版本,下载网址:/pc/support/site.wss/document.do?lndocid=MIGR-605952 安装部分:1)下载Storage manager9.15版本以后,解压到客户端硬盘;2)进入解压的目录\W2KWS03_9P15_IA32\Windows,执行SMA-W32-09.15.35.03.EXE弹出的窗口中选择”运行”3)出现如下界面:注:后台开始出现下面DOS窗口,在后台运行,不要关闭。

4)选择”Next”5)选择”I accept the terms of the License Agreement”,点击”Next”6)选择安装路径或保持默认的路径不变:7)选择”Management Station”(如果选择另外两个选项,可以有机会安装SM agent和RDAC) 8)选择”Do not automatically Start the Monitor”(注:会占用较多的资源,也可以装)9)选择”Install”10)当选择”Done”,后台的DOS程序也会自动关闭,程序中应该已经多出一项”Storage Manage 9 Client”一项,打开即可以使用。

IBM System Storage 产品指南

IBM System Storage 产品指南

Systems and Technology GroupIBMIBM System Storage 产品指南为什么选择IBM信息基础架构IBM信息基础架构可以帮助组织管理数字信息数量和类型令人难以置信的爆炸性增长,即便在经济困难时期也不例外。

IBM信息基础架构可以帮助客户显著存储降低购置成本,同时提高数据弹性和安全性。

如今,IBM提供了采用重复数据删除、虚拟化、加密和固态存储等核心技术的成熟功能。

新的解决方案适用于使用大型机的大型组织及中型组织。

新的Smart Business Systems 可以简化用于归档和网络文件服务的私有云解决方案的部署。

IBM信息基础架构不只是有助于降低成本。

IBM信息基础架构还能为以信息为主导的转型提供重要支持,后者对于许多组织的发展都至关重要。

通过以信息为主导的转型这一过程,组织可以将信息转变为进行创新、业务优化和获得竞争优势的战略驱动力。

以信息为主导的转型可以帮助客户在组织内更深入地运用信息,通过分析预测业务,进行实时决策以及通过手头信息发现各种新的智能。

随着组织构建新的信息驱动或基于信息的产品与服务,吞吐量和可用性要求将会显著增高。

IBM凭借可以打破传统性能障碍的创新技术,以及帮助客户管理过渡的、基于最佳实践的服务来支持以信息为主导的转型。

固态存储的巧妙运用就是一个例子,其中,带有少量固态磁盘的IBM存储阵列和虚拟化控制器可使吞吐量实现显著提升。

可为您的信息基础架构带来强劲动力的IBM核心技术IBM解决方案针对中型组织、大型企业、云计算提供商以及其他组织的独特需求进行了优化。

客户可以获得正好满足其需求的产品,从而节省时间和资金。

选择IBM来帮助您实施下一信息基础架构项目的关键优势在于可以获得多种出色的产品与服务组合。

IBM提供了具有独特价值的顶级专利技术。

IBM的部分特色功能包括:●存储虚拟化- 通过显著提高利用率降低存储区域网络(SAN)磁盘成本。

●重复数据删除- 显著降低存储购置成本,同时降低能源、散热、占地空间和管理需求以及维护成本。

vg镜像的方法将数据转移到新存储设备

vg镜像的方法将数据转移到新存储设备

标题:在AIX中如何使用vg镜像的方法将数据转移到新存储设备产品:P-Server,DS4000,DS6000,DS8000主机平台:IBM eServer pSerise操作系统:AIX其他软件版本:N/A随着设备的更新,用户会经常遇到数据转移的问题。

如何将老的存储设备上的数据转移到新的存储设备上呢?我们下面将举例子,讲解如何使用AIX的vg镜像的方法实现。

mirrorvg功能可以将一个vg中的所有lv都进行mirror。

mirror的目的地盘必须在同一个vg中。

如果将一个vg中的所有逻辑卷进行mklvcopy ,效果等同于mirrorvg。

{smit法:s mit vg/Set Characteristics of a Volume Group/Add a Physical Volume to a Volume Group}现有的环境:我们有2、1)本地磁盘(需要转储的源盘):pv:hdisk1vg:vg-locallv:lv-localfs:/mnt/lv-local2、2)fastt上提供(与本实验无关):pv:hdisk2;hdisk3vg:vg-fastt600lv: lv-fastt600-1fs: /mnt/lv-fastt600-12、3)fastt上提供(需要转储的目的)提供了一个裸盘:pv:hdisk4我们下面的操作是将数据从原始位置pv:hdisk1,移动到fastt上提供(需要转储的目的)提供了一个盘pv:hdisk4上。

我们会利用IBM fastt 的管理软件观察目的盘hdisk4的流量。

还要验证在这个过程中数据的访问是否中断以及移动的效率如何。

先将hdisk4上面的数据毁掉p615:/>tar -cvf /dev/hdisk4 /etca /etc/test/b3 1 blocks.a /etc/test/b4 1 blocks.a /etc/test/b5 1 blocks.a /etc/inittab.tsm 8 blocks.……检验是否毁掉p615:/>tar –tvf /dev/hdisk4-rw-r--r-- 0 0 30 Oct 25 10:21:10 2004 /etc/test/b4-rw-r--r-- 0 0 31 Oct 25 10:21:29 2004 /etc/test/b5-rw------- 0 0 3608 Dec 30 11:17:07 2004 /etc/inittab.tsmdrwxr-xr-x 0 0 0 Jul 16 10:44:15 2004 /etc/tivready/……查看当前情况,建立模拟环境p615:/>lsvg -p vg-localvg-local:PV_NAME PV STATE TOTA L PPs FREE PPs FREE DISTRIBUTION hdisk1 active 8678 8672 1736..1730..1735..1735..1736p615:/>lspvhdisk0 005c39ff63baaa57 rootvg activehdisk1 005c39ffbf1771fc vg-local activehdisk4 none Nonehdisk2 0053f61fd0b7ca1e vg-fastt600 activehdisk3 0053f5ffd0efed59 vg-fastt600 active为了观察fastt上的I/O情况,我们用Storage Manager/Storage Subsystem/Monitor Performance 注:Logical Drive aix3是hdisk4为了测试操作对I/O的连续性的影响,我们在另外的telnet中建立一个脚本work:while [ "1" = "1" ]dotar -cvf /mnt/lv-fastt600-1/usrlib.tar /mnt/lv-local/usrlibsleep 1tar -xvf /mnt/lv-fastt600-1/usrlib.tar /mnt/lv-local/usrlibsleep 1done让/mnt/lv-local文件系统持续被读写。

StorageManager存储管理软件

StorageManager存储管理软件

DS4000StorageManager存储管理软件DS4000 StorageManager存储管理程序软件为管理IBM DS4000存储系统提供了一种基于Java的功能强大、操作简单、直观而易使用的图形用户界面(GUI)。

DS4000 StorageManager软件允许在不中断业务的情况下在线配置系统、在线微码升级、在线动态磁盘扩展以及其它维护操作。

它对所有的操作系统都提供一致的界面,该管理软件允许从网络中的任何位置对一个或多个IBM DS4000存储系统进行监控和管理。

DS4000 StorageManager软件的高级功能——存储器分区(Storage Partition)、卷快照(FlashCopy)、卷拷贝(Volume Copy)和远程卷镜像功能(MetroMirror/GeoCopy/GeoMirror )——是完全集成的,它为所有的存储器管理、分区和复制功能提供单一的控制操作。

DS StorageManager 基本功能∙集中式的管理——监控和管理来自任何网络位置的所有IBM DS4000存储器∙直观的GUI——DS4000 StorageManager软件的阵列管理窗口(AMW)以一种很容易理解的界面方式显示了这样一些信息:存储系统的逻辑组件(存储器卷和卷组)、物理组件(控制器和驱动器)、拓扑元素(主机组、主机、主机端口)以及卷到LUN之间的映射。

对于某个选定的存储系统或者选定的组件,所有存储管理操作都可以从对应的AMW菜单中运行,或者也可以通过右键点击对应的选项来运行。

∙配置的灵活性——所有卷的设置都是单独配置,保证能够满足某个特殊卷准确需要的特性。

卷配置的设置包括:容量、分段大小、修改优先级、允许/禁止读缓存、允许写缓存(回写式)、禁止写缓存(直写式)、允许/禁止写缓存镜像、预读乘法器、允许/禁止电池备份的写缓存,以及允许/禁止后台硬盘扫描(带冗余校验或不带冗余校验)。

IBMDS存储的配置步骤

IBMDS存储的配置步骤

DS3500或5020配置步骤(单控)1,物理连接管理端和盘柜的方法:先把管理端的IP 改为192.168.128.100(不能占用101,101为控制器默认链接IP)用一根网线把管理端的机器的网口和存储上的ENT1口连起来,然后在cmd里ping 192.168.128.101ping通就可以打开IBM DS SM管理软件2,找出随机的system storage DS3500或5020 support software 光盘双击后第一界面点OK 点NEXT继续NEXT然后点击NEXT继续NEXT点击OK继续NEXT弹出任何界面都OK然后点击INSTALL开始安装,安装完成,开始菜单里找到如下点DS storage manager client,打开管理软件如下图界面,右击小电脑图标,弹出三个选项选择Out-of-band management再第一个空白处输入A控制器的管理IP 如上,然后点击ADD ,当添加完成,会询问是否继续添加,点NO正常添加完成后如图系统会要求强制设置,密码复杂性要满足大小写加数字加特殊符号:如Abc!@#123<>设置成功就可以进入管理界面了如图单击Logical右击unconfigured capacity ,选择create arrayNEXTARRAY NAME 可以自定义,随便输入继续NEXT选择好之后finish 完成array创建点击yes,开始创建LUNNEXT选择好之后NEXT结束LUN的创建如需继续创建新的LUN 可以点击yes 如果不需要点击NO开始映射的步骤(mapping)选择DEFINE , HOST GROUP为创建主机组HOST 为单台主机定义一个主机NAME同样可以随意输入,然后NEXT识别完成后NEXT,选择主机的操作系统类型后,finish 完成选择DEFINE ADDITIONAL MAPPING,add完后close 关闭对话框映射完成后可以看到对应主机里的LUN现在可以重启服务器,打开磁盘管理,查看到映射过来的LUN,服务器里显示为磁盘N,如果服务器里多了个莫名其妙的几十M的小盘在SM的mapping里把Access remove掉右击Access 选择remove mapping输入yes 点击OK然后刷新下磁盘管理或重启服务器,几十M的小磁盘就消失了。

IBM DS8000主要硬件介绍

IBM DS8000主要硬件介绍

DS8000主要硬件部件介绍本文主要介绍了DS8000的处理器抽屉,处理器内存(Processor memory),RIO-G,I/O抽屉(I/O enclosures),设备卡(Device adapters)和磁盘抽屉(Disk enclosures)。

处理器抽屉(Processor complex)DS8000 基本机柜(base frame)中包含两个处理器抽屉. 9x1 型号包含双2-路处理器,9x2 型号包含双4-路处理器. (双2-路表示每个处理器抽屉包含 2 CPUs, 双4-路表示每个处理器抽屉包含4 CPUs.)下图是DS8000处理器抽屉的前面和后面视图。

图-1 处理器抽屉一个处理器抽屉主要包括:_ 5个hot-plug PCI-X slots with Enhanced Error Handling (EEH)_ 2个Ultra320 SCSI controllers_ 1个10/100/1000 Mbps integrated dual-port Ethernet controller_ 2个serial ports_ 2个USB 2.0 ports_ 2个HMC Ethernet ports_ 4个remote RIO-G ports_ 2个System Power Control Network (SPCN) ports处理器内存(Processor memory)DS8300处理器内存最多可达256 GB ,DS8100处理器内存最多可达128 GB 。

每个处理器抽屉各占一半内存。

处理器内存又分为volatile 内存和persistent 内存(又叫NVS(non-volatile storage))。

volatile 内存用来作为一般意义上的cache使用。

persistent 内存是用来保存DASD fast write (DFW) 数据,直到数据全部写到硬盘上为止。

各厂商磁盘阵列介绍

各厂商磁盘阵列介绍

磁盘阵列的基础知识
RAID 5(无独立校验盘的奇偶校验磁盘阵列 ):RAID 5不 单独指定的奇偶盘,而是在所有磁盘上交叉地存取数据 及奇偶校验信息。在RAID 5上,读/写指针可同时对阵列 设备进行操作,提供了更高的数据流量。RAID 5更适合 于小数据块和随机读写的数据。
磁盘阵列的基础知识
RAID 6:与RAID 5相比,RAID 6增加了第二个独立的奇偶校 验信息块。两个独立的奇偶系统使用不同的算法,数据 的可靠性非常高,即使两块磁盘同时失效也不会影响数 据的使用。但RAID 6需要分配给奇偶校验信息更大的磁 盘空间,相对于RAID 5有更大的“写损失” 。
企业级磁盘系统
Sun StorageTek 9990 Sun StorageTek 9985 Sun StorageTek 9980
IBM
DS300 DS400 DS4100(FAStT100)
DS6000 系列 DS8000 系列
HP
HP StorageWorks MSA20/30 HP StorageWorks MSA500 HP StorageWorks MSA1000 HP StorageWorks MSA1500
IBM、HP、SUN产品介绍设备SUN入门级磁盘系统
Sun StorageTek 3511 SATA Sun StorageTek 3510 FC Sun StorageTek 3320 SCSI
中端磁盘系统
Sun StorageTek 6130 Sun StorageTek 6140 Sun StorageTek 6540 DS4100(FAStT100) DS4300(FAStT600) DS4400(FAStT700) DS4500(FAStT900) DS4700 DS4800

IBM ds8000配置手册

IBM ds8000配置手册

目录目录1 文档版本.............................. 错误!未定义书签。

2 DS8000逻辑配置 (3)2.1 关于虚拟化存储的几个重要概念 (3)2.2 安装DSCLI (8)2.3 激活DS8000 license (10)2.4 DS8000逻辑配置 (11)2.4.1 列出arraysite (12)2.4.2 创建Array (12)2.4.3 创建RANK (15)2.4.4 创建Extend Pool (15)2.4.5 将rank加入到相应的extend pool (16)2.4.6 创建LUN (17)2.4.7 创建volume group (19)2.4.8 将LUN加入到需要的volume group中 (22)2.4.9 创建host connection (22)2.4.10 用脚本执行命令 (25)2.4.11 主机端安装SDD软件,识别vpath (26)1 DS8000逻辑配置1.1 关于虚拟化存储的几个重要概念Storage Hierarchy▪DiskIndividual DDMs▪Array SitesPre-determined grouping of DDMs of same speed and capacity (8 DDMs for DS8000; 4 DDMs forDS6000)▪ArraysOne 8-DDM Array Site used to construct one RAID array (DS8000)One or two 4-DDM Array Sites used to construct one RAID array (DS6000)▪RanksOne Array forms one CKD or FB Rank (4 or 8 DDMs)No fixed, pre-determined relation to LSS▪Extent PoolsAll Extents in a Pool are same storage type (CKD/FB); same RAID recommendedAssociated with Server0 or Server1 (DS8000)–Controller 1 or Controller 2 (DS6000)Extent Pools▪User-configured to be either CKD or FB▪Contain one or more ranks divided into fixed-sizeextentsCKD –3390 Mod1FB –1GBRecommend one rank per pool as inexample --▪Contain one or more LUNs/volumes made up ofextents2 volumes in the example (2310,7501)–xyzz(x=address group, xy=LSS, zz=volid)▪Extent pool is assigned to Server0 or Server1during configuration (‘server affinity’)By user during custom configurationBy algorithm during auto or expressconfigurationServer1 in the example–Indicated by odd-numbered LSSsExtent Pool 3▪Minimum of 2 pools to utilize subsystemServer0 and Server1▪Maximum of n pools where n is the number of ranks in subsystem8 pools/8 ranks in the example▪Extent pool can contain one or more ranksRecommend one rank per extent pool unless a volume size larger than one rank is requiredOne rank per pool means pool containsLUNs/volumes on one rank onlyOne rank per pool will not constrain addresses–Volumes on one rank in one pool can be in multiple LSSs–Volumes on different ranks in different pools can be in the same LSS (limited by odd/even server affinity)▪Rank can be added to extent pool at any time▪Rank can be removed from extent pool if no extents on rank are currently assigned to LUNs/volumesExt. Pool 5Rank 5Ext. Pool 1Rank 1Ext. Pool 3Rank 3Ext. Pool 7Rank 7 Ext. Pool 4Rank 4Ext. Pool 0Rank 0Ext. Pool 2Rank 2Ext. Pool 6Rank 6……LSSs/LCUs▪Logical grouping of volumesDetermines addressing, address group, and PAVs–Max of 256 addresses in LSS–16 LSSs in an address group (00-0F, 10-1F, 20-2F, etc.)– A given PAV can only be used within one LCUAlso used for copy services PPRC paths and consistency groupproperties/timeouts▪Maximum number of LSSsDS8000 –128 at GA (max 16 ESCON CKD, max 64 FICON CKD, max 64 FB)DS6000 –32 at GA (no ESCON, max 32 CKD if no FB, max 32 FB if no CKD, max 16CKD+16FB if mixed)▪Pre-determined association with Server0 or Server1Even LSSs associated with Server0Odd LSSs associated with Server1▪LSS configured to be either FB or CKDCKD –during LCU creationFB –during volume creation▪No pre-determined relation to physical ranks▪No pre-determined relation to extent pools other than server affinityOne LSS can contain volumes from different pools One pool can contain volumes that are in different LSSsOne LCU can contain CKD volumes of different types (3390 M3s & M9s)Many-many relationship▪LSS definitionCKD –during LCU creation FB –during volume creation ▪LSSs numbers are pre-grouped in groups of 16 LSSs to make up address groupsLSSs 00-0F --address group 0, LSSs 10-1F --address group 1, etc.LSS 23 in the example is in address address group 7Entire address group (all 16 LSSs) will be either FB or CKDDS8000 --8 address groups at GADS6000 –2 address groups at GAVolumes▪One logical volume is made up of extents from one extent pool Typically made up of extents from one rank unless LUN size is larger than one rank▪A specific volume is in one LSS▪Multiple volumes in one extent pool or on one rank can be in the same or different LSSs▪Multiple volumes in different extent pools and on different ranks can be in the same LSS▪Minimum volume/LUN size is one extentCKD –Mod1FB –1 GB▪Note –volume sizes are now given in binary (e.g. 1GB=1073741924 bytes) ESS volume sizes were given in decimal (e.g. 1GB=1000000000 bytes)▪Maximum volume/LUN sizeCKD 56GB–With appropriate zSeries software supportFB2TB–Or capacity of one rank when using one rank per extent pool▪Maximum number of volumes/LUNsDS8000 –32K at GA (16K max FB; 16K max CKD)DS6000 –8K (8K max CKD if no FB; 8K max FB if no CKD; 4K max CKD/4K max FB if mixed)▪Volumes can be deleted and extents reusedHosts▪Multiple server ports can be specified (in one or more groups) in one host definitionFour host attachments (one port each) are shown for pSeries1Server ports can be grouped for convenience–Two host attachments with 2 ports each are shown for pSeries2–One host attachment with 4 ports is shown for pSeries3▪A host attachment can accessSpecific disk subsystem I/O ports “All valid ”disk subsystem I/O ports ▪A specific host attachment can be inonly one volume group▪Host attachments are assigned to volume groups▪Specific host attachment (one port or set of grouped ports) can be in only one volume group▪Multiple hosts (even different open systems host types --with same blocksize and addressing mode) allowed in same volume groupSafest approach is one host per volume groupIf shared access to LUNs is required, shared LUNs may be placed in multiple volume groups (e.g. LUN1 below)Volume Group 2Volume Group 1Volume Groups▪FB LUN masking▪Contains one or more host attachments and one or more LUNs▪A specific host attachment can be in only one volume group▪Attachments from multiple hosts (even different open systemshost types) are allowed in the same volume groupRecommend one host per volume group with shared LUNs in multiple volume groups▪Specific LUN can be in more than one volume groupAllows LUN sharing (e.g. LUN1 in example below)Volume Group 1Volume Group 2▪Volumes from different LSSs and different Extent Poolscan be in one volume group (Volume Group 1 below)▪Volumes from same LSS and/or same Extent Pool can bein different volume groups (7512, 7515)1.2 安装DSCLI为提高配置的速度,建议大家划分DS8000采用DSCLI(DS Command Line Interface),在笔记本上安装DSCLI后(执行命令setupwin32.exe),修改其C:\Program Files\IBM\dscli\profile\ dscli.profile,如下:# Management Console/Node IP Address(es)# hmc1 and hmc2 are equivalent to -hmc1 and -hmc2 command# options.hmc1: 172.16.0.1#hmc2: 127.0.0.1## Default target Storage Image ID# "devid" and "remotedevid" are equivalent to# "-dev storage_image_ID" and "-remotedev storeage_image_ID"# command options, respectively.devid: IBM.2107-7523201# locale# Default locale is based on user environment.locale: en其中hmc1为DS8000的HMC地址,此处为HMC缺省IP172.16.0.1; devid 为DS8000的storage facility image ID,为IBM.2107-7523201。

ibm storage manager使用手册

ibm storage manager使用手册

ibm storage manager使用手册IBM Storage Manager是一款强大的存储管理工具,它可以帮助用户快速而方便地管理存储池、磁盘框、RAID控制器以及硬盘等存储资源。

对于首次使用IBM Storage Manager的用户来说,这里提供了一份详细的使用手册,帮助大家快速了解和掌握该软件的使用方法。

1. 软件安装首先,用户需要在官网下载并安装IBM Storage Manager软件,根据自己的操作系统版本选择安装包并按照提示完成安装。

2. 连接存储设备安装完成后,用户需要连接存储设备并将其添加到IBM Storage Manager中进行管理。

打开软件,点击“资源管理器”菜单进入资源管理器界面,点击“添加存储池”按钮,依次输入存储设备的IP地址、用户名、密码以及存储设备类型等相关信息,然后点击“连接”按钮。

3. 创建存储池连接成功后,用户就可以开始创建存储池了。

依次点击“存储管理”菜单的“存储池”选项,在右侧的窗口中选择相应的存储设备,然后点击“添加存储池”按钮,输入存储池的名称、RAID等级、容量等相关信息,最后点击“确定”按钮完成存储池的创建。

4. 添加磁盘框在存储池创建完成后,用户还需要添加磁盘框并初始化硬盘。

依次点击“存储管理”菜单的“磁盘框”选项,在右侧的窗口中选择相应的存储池,然后点击“添加磁盘框”按钮,按照提示完成磁盘框的添加和硬盘的初始化。

5. 创建虚拟磁盘磁盘框添加完成后,用户可以开始创建虚拟磁盘了。

依次点击“存储管理”菜单的“虚拟磁盘”选项,在右侧的窗口中选择相应的存储池,然后点击“添加虚拟磁盘”按钮,输入虚拟磁盘的名称、RAID等级、容量等相关信息,最后点击“确定”按钮完成虚拟磁盘的创建。

6. 创建主机最后,用户还需要创建主机并为其分配虚拟磁盘。

依次点击“主机管理”菜单的“主机”选项,在右侧的窗口中点击“添加主机”按钮,输入主机的名称和IP地址等相关信息,然后点击“确定”按钮完成主机的创建。

IBM 软件定义存储介绍

IBM 软件定义存储介绍

Emails
App dev
GRID
OLTP
Archive
2
传统和下一代的应用程序分别拥有各自独特的需求
传统的工作负载
交易事务系统 Email, 供应链, HR 虚拟服务器和虚拟桌面
全新的工作负载
社交媒体
综合办法
移动应用 大数据&分析
Systems of Record
得益于简化的基础架构 通过提升虚拟化和自动化获得更有效的 成本使用 驱动控制数据的增长
FlashSystem DS8000
XIV
SONAS
For Midrange and Entry Workloads
Tivoli Key Lifecycle Manager
DCS3700
Storwize V3700 & V5000
Storwize V7000
Storwize V7000 Unified
I/O Time
Network Time
CPU Time
I/O Time
Network Time
CPU Time
Time Recovered
• 消除等待时间 • 通过增加存储容量提升性能
1 毫秒 : 1 秒 :: 1 秒 : 11.5 日
10
Flashsystem 极致性能价值
极致性能
业务运作得以释放其性能,拓展宽度,提高响应从而驱动服务和产品更好 更快的投入和应对市场变化
企业级的可靠 性
• 全冗余架构& 支持热插拔 • 在线微码升级 • 基于AES 256, HW加密
7
FlashSystem 840 将取代您数据中心中的高性能硬盘
性能概览

如何安装Storage Manager管理软件客户端并调IBM DS系列存储

如何安装Storage Manager管理软件客户端并调IBM DS系列存储

如何安装Storage Manager管理软件客户端并调IBM DS系列存储如何安装Storage Manager 9.15客户端并调试IBM DS系列存储一、安装 Storage Manager 9.15 管理软件客户端当前IBM提供的最新Storage Manager版本为09.15(其实已经有更新的了在LSI网上有下载)。

这个版本采用了新的打包分发模式,安装与先前的版本有所不同,这里对客户端软件的安装进行介绍。

1 准备工作:1)一台台式机或者笔记本电脑;注明:用作客户端,从这台电脑上面管理DS4000产品;2)以太网线(如果有交换机的话)或者直连线(如果没有交换机的话)注明:线缆用作连接客户端和DS4000上面的以太网口3)配置客户端的ip地址和DS4000的IP地址在同一个网段(DS4000的默认的IP地址是:控制器A:192.168.128.101,控制器B:192.168.128.102;DS4800的控制器A主机端口2:192.168.129.101,DS4800的控制器B主机端口2:192. 168.129.102)进行”ping”的测试,确保连通;4)下载storage manager9.15(58MB)版本,下载网址:/pc/support/site.wss/doc ument.do?lndocid=MIGR-605952 安装部分:1)下载Storage manager9.15版本以后,解压到客户端硬盘;2)进入解压的目录\W2KWS03_9P15_IA32\Windows,执行SMA-W32-09.15.35.03.EXE弹出的窗口中选择”运行”3)出现如下界面:注:后台开始出现下面DOS窗口,在后台运行,不要关闭。

4)选择”Next”5)选择”I accept the terms of the License Agreement”,点击”Next”6)选择安装路径或保持默认的路径不变:7)选择”Management Station”(如果选择另外两个选项,可以有机会安装SM agent和RDAC)8)选择”Do not automatically Start the Monitor”(注:会占用较多的资源,也可以装)9)选择”Install”10)当选择”Done”,后台的DOS程序也会自动关闭,程序中应该已经多出一项”Storage Manage 9 Client”一项,打开即可以使用。

IBM DS8000系列巡检方法

IBM DS8000系列巡检方法

DS8000系列巡检方法一、查看Open Service Event1.登陆HMC,Web-based System Manager(WebSM)会自动打开。

用户名:CE密码:serv1cece (中间为数字1)2.选择Service Focal Point中的Manage Serviceable Events:3.默认选项是只查看“OPEN”的Service Event:4.正常情况下不应该有OPEN的Service Event:5.如果有OPEN的Service Event,可以看到Event的ID、SRC号码、首次发现时间和最后一次的发现时间。

可以选择“View Details”查看Event的Detail:6.可以看到Event所指向的备件号、描述和位置号Location Code:注意:并不是每一种Event都会使DS8000的故障灯亮起。

因此就算故障灯没有亮起,都要查看Open Service Event和运行End Of Call!!!如果Event的“Notification Type”是“Call Home and Customer Notify Required”,那么故障灯会马上亮起,机器也会Call Home(如果已配置Call Home);如果Event的“Notification Type”是“No Call Home and Customer Notify Required”,那么故障灯不会亮起,机器也不会Call Home(例如DDM故障状态是Deferred Service)二、运行“View Storage Facility State”检查DS8K状态1.打开Service Focal Point,选择Service Utilities2.在弹出的窗口中选中相应的Storage Facility3.在“Selected”菜单中选择“View Storage Facility State”4.系统检查会运行3至5分钟:5.结果如下。

IBM 低端存储介绍

IBM  低端存储介绍
TotalStorage Productivity Center Tivoli Provisioning Manager Tivoli Storage Process Manager IBM Systems Director
磁带系统
TS family Virtual Tape Server Peer-to-Peer
IBM System Storage DS 磁盘家族系列
部门级存储 中端系列 微缩版高端存储 企业级高端存储
DS3000
DS4000
DS6000
DS8000
IBM 创新的存储设计帮助实现 创新的存储设计帮助实现:
简化IT架构 简化 架构 保持业务持续运行 让数据实现业务价值
© 2008 IBM Corporation
Blade 刀片中心
首选 DS3000 对存储功能和存储服务多样性有要求可考虑N 系列网络存储
Unix 小型机 – IBM p 系列
推荐 DS4000 高端小型机推荐 DS8000 对存储功能和存储服务多样性有要求可考虑N 系列网络存储
IBM 主机系统 – DS8000
© 2008 IBM Corporation
Systems & Technology Group
磁盘系统-DS3000
v v
© 2008 IBM Corporation
IBM System Storage™
市场增长预测-中低端存储增长最迅速
低端存储增长速度远远高于高端,这与SMB市场的迅猛发展不无关联
5 4.5 4 3.5 3
48%
15%
IBM Systems
System StorageTM
存储接口的比较

如何安装Storage Manager管理软件客户端并调IBM DS系列存储

如何安装Storage Manager管理软件客户端并调IBM DS系列存储

如何安装客户端并调试系列存储
一、安装管理软件客户端
当前提供的最新版本为(其实已经有更新的了在网上有下载)。

这个版本采用了新的打包分发模式,安装与先前的版本有所不同,这里对客户端软件的安装进行介绍。

准备工作:
)一台台式机或者笔记本电脑;
注明:用作客户端,从这台电脑上面管理产品;
)以太网线(如果有交换机的话)或者
直连线(如果没有交换机的话)
注明:线缆用作连接客户端和上面的以太网口
)配置客户端的地址和的地址在同一个网段
(的默认的地址是:控制器:,控制器:;的控制器主机端口:.,的控制器主机端口:.)进行””的测试,确保连通;
)下载()版本,下载网址:
安装部分:
)下载版本以后,解压到客户端硬盘;
)进入解压的目录\\,执行09.15.35
弹出的窗口中选择”运行”
)出现如下界面:
注:后台开始出现下面窗口,在后台运行,不要关闭。

)选择””
)选择” ”,点击””。

ibmstoragemanager使用手册

ibmstoragemanager使用手册

ibmstoragemanager使用手册IBM Storage Manager 是 IBM 公司开发的一款高性能、可靠的存储管理软件。

它提供了一个集中式的管理界面,帮助企业管理和监控存储设备、存储资源的使用情况,以及进行存储资源的优化配置和故障排查等工作。

以下是 IBM Storage Manager 的使用手册,详细介绍了该软件的功能和使用方法。

第一章:介绍1.1 什么是 IBM Storage Manager1.2功能概述1.3系统需求第二章:安装和配置2.1 安装 IBM Storage Manager2.2配置存储设备2.3配置存储资源2.4配置存储策略第三章:存储设备管理3.1设备发现和识别3.2存储设备添加和删除3.3设备信息查看和修改3.4存储设备性能监控3.5存储设备故障排查和维护第四章:存储资源管理4.1存储资源发现和识别4.2存储资源添加和删除4.3存储资源配置和分配4.4存储资源性能监控4.5存储资源故障排查和优化第五章:存储策略管理5.1存储策略配置和管理5.2存储策略应用和调整5.3存储策略监控和报警5.4存储策略优化和维护第六章:备份和恢复6.1数据备份和恢复概述6.2数据备份配置和管理6.3数据恢复操作和策略6.4备份和恢复监控和报告第七章:性能优化和故障排查7.1性能优化策略7.2故障排查和维护工具7.3存储性能监控和报告7.4性能调优和容量规划第八章:安全管理和授权8.1安全管理概述8.2用户和角色管理8.3权限配置和审计8.4安全策略和防护第九章:升级和维护9.1软件升级功能9.2维护和运维工作9.3系统日志和错误处理9.4报表和数据分析第十章:常见问题解答10.1安装和配置问题解答10.2设备管理问题解答10.3资源管理问题解答10.4存储策略问题解答10.5性能优化和故障排查问题解答结论以上是 IBM Storage Manager 使用手册的大致内容。

IBM DS8000配置文档

IBM DS8000配置文档

DS8K逻辑配置文档 Step By Step目 录1.1 安装DSCLI (2)1.2 激活DS8000 license (3)1.3 DS8000逻辑配置 (5)1.3.1 列出arraysite (6)1.3.2 创建Array (6)1.3.3 创建RANK (9)1.3.4 创建Extend Pool (9)1.3.5 将rank加入到相应的extend pool (10)1.3.6 创建LUN (11)1.3.7 创建volume group (16)1.3.8 将LUN加入到需要的volume group中 (17)1.3.9 创建host connection (18)1.3.10 用脚本执行命令 (21)1.3.11 主机端安装SDD软件,识别vpath (22)1.1 安装DSCLI为提高配置的速度,建议大家划分DS8000采用DSCLI(DS Command Line Interface),在笔记本上安装DSCLI后(执行命令setupwin32.exe),修改其C:\Program Files\IBM\dscli\profile\ dscli.profile,如下:# Management Console/Node IP Address(es)# hmc1 and hmc2 are equivalent to -hmc1 and -hmc2 command# options.hmc1: 172.16.0.1#hmc2: 127.0.0.1## Default target Storage Image ID# "devid" and "remotedevid" are equivalent to# "-dev storage_image_ID" and "-remotedev storeage_image_ID"# command options, respectively.devid: IBM.2107-7523201# locale# Default locale is based on user environment.locale: en其中hmc1为DS8000的HMC地址,此处为HMC缺省IP172.16.0.1; devid为DS8000的storage facility image ID,为IBM.2107-7523201。

DS_Storage_manager使用文档

DS_Storage_manager使用文档

DS Storage Manager的使用(一)Storage PartitionStorage Partition 即LUN Masking技术,即采用LUN屏蔽方式实现不同主机之间的存储空间隔离。

该技术与光纤交换机的Zoning技术类似,都是对访问控制器进行限制。

Zoning是确定哪个主机可以访问哪个存储,Storage Partition是进一步限定这个主机只可以访问该存储的哪个/哪些LUN。

例如,一台Linux主机在使用的LUN如果不通过Storage Partition与一台Windows主机隔离,Windows操作系统就会在看见的磁盘上签名,这样就会损坏该LUN的数据。

再例如,多台主机同时看见某个LUN,同时往里面写数据,就会出现数据互相覆盖,破坏的问题。

采用Storage Partitions后,每个主机只能看到自己的LUN,就解决了上述的问题。

所以订购DS4000的时候应该订购Storage Partition的License。

(二)怎样使用Storage Partition每个Storage Partition 都可以对一台机器或者一组机器做LUN的限定。

有两种可选方案:1.为每台主机或者每两台安装了群集软件的主机设定一个Storage Partition。

也就是说一个Host Group里包含一个或两个Host, 两台主机共享的逻辑盘分配给Host Group,两台主机各自独占的逻辑盘分配给Host。

优点是共享和独占设定灵活,维护容易,逻辑清楚,是建议的方式。

值得注意的是,如果是一组机器在一个Storage Partition中,他们应该有群集软件或者类似于IBM的SAN File System,SANergy或者GPFS这样的软件来协调各个主机的共同访问。

如下图, p570_node1 和 p570_node2共享所有的逻辑盘,操作系统上安装了HACMP来解决争用。

2.一个Host Group里包含多个Host,分配逻辑盘的时候直接分配给每个Host。

DS8K逻辑配置

DS8K逻辑配置

目录1.1 安装DSCLI (2)1.2 激活DS8000 license (3)1.3 DS8000逻辑配置 (5)1.3.1 列出arraysite (6)1.3.2 创建Array (6)1.3.3 创建RANK (9)1.3.4 创建Extend Pool (9)1.3.5 将rank加入到相应的extend pool (10)1.3.6 创建LUN (11)1.3.7 创建volume group (16)1.3.8 将LUN加入到需要的volume group中 (17)1.3.9 创建host connection (18)1.3.10 用脚本执行命令 (21)1.3.11 主机端安装SDD软件,识别vpath (22)1.1 安装DSCLI为提高配置的速度,建议大家划分DS8000采用DSCLI(DS Command Line Interface),在笔记本上安装DSCLI后(执行命令setupwin32.exe),修改其C:\Program Files\IBM\dscli\profile\ dscli.profile,如下:# Management Console/Node IP Address(es)# hmc1 and hmc2 are equivalent to -hmc1 and -hmc2 command# options.hmc1: 172.16.0.1#hmc2: 127.0.0.1## Default target Storage Image ID# "devid" and "remotedevid" are equivalent to# "-dev storage_image_ID" and "-remotedev storeage_image_ID"# command options, respectively.devid: IBM.2107-7523201# locale# Default locale is based on user environment.locale: en其中hmc1为DS8000的HMC地址,此处为HMC缺省IP172.16.0.1; devid为DS8000的storage facility image ID,为IBM.2107-7523201。

DS8000的概念

DS8000的概念

本文介绍IBM DS8000存储中的Arrays,Ranks,Extent pools的概念。

DDM一个磁盘驱动器模块(Disk Drive Module (DDM))是一个可替换的单元,包含一块单独的磁盘和它相应的包装。

DDMs 订购是以16块盘为一组,又叫做一个a drive set. 一个 driv e set 是跨两个disk enclosures, 8个 DDMs 在前面的(front) disk enclosure ,8个DDM s 在后面的(rear) disk enclosure. 当订购disk enclosures 时,它们是成对出现的,每个可以插16块硬盘。

如果任何一个 disk enclosure 没有插满 DDMs, 则空的槽位必须被哑盘(dummy carriers )来填充,又叫做disk enclosure fillers. (磁盘盒填料)Disk enclosure f illers 可以以16为一组来订购。

Array sitesArray site 是用于定义arrays的building blocks。

一个 array site 是一组硬盘,由8块相同转速和容量的硬盘组成,这8块硬盘会从位于不同环路里的2个disk enclosures 里选择,例如:4块硬盘来自环路1,另外4块硬盘来自环路2。

通常都是4块磁盘来自一个后面的(rear )disk enclosure ,4块磁盘来自前面的(front) disk enclosure 。

Arrays一个 array 是在一个array site里创建,创建一个array意味着首先要定义一个特定的RAID 类型,DS8000支持的RAID 类型是RAID-5 和RAID-10 . 对于每一个array site ,你可以选择一个RAID 类型,为一个array选择RAID类型的过程也叫做定义一个 array。

对于DS8000 热备盘的算法(sparing algorithm),一个array site可以定义0到2个热备盘。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

IBM Storage Educationh
®
Session SDSK09
DS8000 Storage Manager Lab
Michael S Downie
Simulated Mode
Go, executes Selected Action
Clicking on the pull-down box as shown above to Select Action
Clicking on this icon you can Clear All Sorts.
Clicking on this icon you can Edit Sort.
Clicking on this icon you can Clear All Filters.
Clicking on this icon you can Show Filter Row
Clicking on this icon you can Deselect All.
Clicking on this icon you can Select All.
The caret is for a simple ascending/descending sort on a
single column.
Two methods - auto and custom Select number of arrays to configure
Select RAID type
Arrays distributed evenly across servers
Select the Array Sites and RAID type
Display Arrays
Display Ranks
Defining Volumes
Create an Extent Pool (custom)
Select the Storage and RAID type and Server
Select some Fixed Block Ranks for the Pool
Verify the Extent Pool parms
Success!
Passwords
Windows base - ???????
VMware Image - smartway
DS SM GUI - admin / passsw0rd
Create some Open Systems LUNs
Select a Fixed Block Extent pool
Select Standard DS sizes (binary GB)
Select Volume size and number and LSS
Verify Parms
Success!
Create Open Host Attachment
Add two HBAs for selected host
Define WWPNs of host ports
Add host to Storage Image
Apply Host Attachment
Verify Host Attachment
Create Windows Volume Group
Select Host Attachment defined earlier
Select Volumes defined earlier
Verify Volume Group parms
Done!。