NACEN2R2M504x5.5TR13F中文资料

合集下载

NETGEAR N450 WiFi 路由器 WNR2500 产品介绍说明书

NETGEAR N450 WiFi 路由器 WNR2500 产品介绍说明书

Performance & UseThe NETGEAR Difference - WNR2500OverviewN450 routers †® genie ® App—Home networking simplified• Power Boost antennas for better range • NETGEAR ® genie ®• Live Parental ControlsN450 Wireless RouterData Sheet WNR2500The NETGEAR N450 Wireless Router (WNR2500) offers WiFi speeds up to 3x faster than competing N450 routers. This router delivers high-performance wireless speeds for faster downloads, Internet gaming and HD streaming. The WNR2500 includesadvanced features such as Power Boost antennas for better range, Live Parental Controls for safer web surfing on connected devices, and NETGEAR genie ® home network manager for easy installation and home network management.• Home network manager• Turbo Transfer—share files within your home network between PC, Mac or Android• Makes any printer AirPrint ® compatible to print from an iPad ® or iPhone ®• MyMedia ™—Find & play media files in your network• EZ Mobile connect—Scan QR code to connect to your home network • For PC, Mac ®, iPhone ®, iPad ®, & Android ™ devicesNETGEAR genie ® Home Networking SimplifiedN450 Wireless RouterData Sheet WNR2500Get the speed you need and faster connections! With N450 WiFi you'll enjoy a better Internet experience on all your WiFi devices.Relive memories and share them with others. Enjoy photos, videos and music stored on a shared USB hard drive. If it's secure and shared storage access you want, NETGEAR has easy ways to do it.Stay connected—with your devices, your media, and your friends. The advanced QoS technology provides higher priority for media streamingapplication for smoother HD video streaming and low-latency online gaming.SpeedSharingReliable ConnectionsWiFi RangeN450 WIFI—Faster downloads, Internet gaming, & HD streamingWIRELESS-N —Email, chat, surf, music, videoRANGE—For medium to large homesADVANCED QoS—Optimized for smooth HD streaming & gamingBetter WiFi Speed Better WiFi Range Share & stream your movies, music, photos Enjoy better connectivity throughout your home Homes come in all shapes and sizes. The NETGEAR N450 Wireless Router provides better WiFi connectivity throughout your home for all your Internet-enabled devices.WIFI COVERAGE—Power Boost 5dBi omni-directional antennas forbetter Wifi coverageN450 Wireless RouterData Sheet WNR2500Start enjoying your new devices faster than ever. NETGEAR wants to make sure installation and network management is simple and easy, so you can connect quickly and stay that way!Maintain high security across your network to helpensure your privacy and family is safe while online. Whether it’s preventing phishing and spyware or just limiting access for kids and guests, NETGEAR has you covered.Access to the Internet is a crucial part of your day and you need to make sure your router can support all you do. With N450 WiFi you'll experience better connections for your needs.Ease Of UseSecurityApplicationsEASY INSTALL—Easy setup for iPad ®, tablets, smartphones & computersPARENTAL CONTROLS—Safer web surfing for all your connected devicesEMAIL, CHAT, SURF, MUSIC, VIDEO—Enjoy a fast, reliable and secure wireless connection to the InternetNETGEAR GENIE ® APP—Personal dashboard to monitor, control & repair your home networkGUEST NETWORK ACCESS—Separate & secure access for guestsO NLINE GAMING—Optimized for multi-player gaming with no lags PUSH ‘N’ CONNECT —Easy push button WiFi connections (WPS)WIFI & POWER ON/OFF —Convenient power savingsSECURE WIFI CONNECTIONS—High level wireless security with WPA/WPA2Simple network management Safeguard your network Ideal UsesN450 Wireless RouterData Sheet WNR2500Connection DiagramInternetFast EthernetThis product is packaged with a limited warranty, the acceptance of which is a condition of sale. This product has been tested for quality assurance and it or its components may have been recycled.*24/7 basic technical phone support provided for 90 days from purchase date.†Maximum wireless signal rate derived from IEEE standard 802.11 specifications. Actual data throughput and wireless coverage will vary. Network conditions and environmental factors, including volume of network traffic, interference, and building construction may lower actual data throughput and wireless coverage. NETGEAR makes no express or implied representations or warranties about this product’s compatibility with any future standards. 802.11n 450 Mbps is approximately 3x faster than 802.11n 150 Mbps.NETGEAR, the NETGEAR Logo, ReadySHARE, and NETGEAR genie, are trademarks and/or registered trademarks of NETGEAR, Inc. and/or subsidiaries in the United States and/or other countries. Other brand names mentioned herein are for identification purposes only and may be trademarks of their respective holder(s). Information is subject to change without notice. ©2016 NETGEAR, Inc. All rights reserved.NETGEAR,Inc.350E.PlumeriaDrive,SanJose,CA95134-1911USA,1-888-NETGEAR(638-4327),E-mail:****************,D-WNR2500-1N450 Wireless RouterData Sheet Package Contents• N450 Wireless Router (WNR2500)• Ethernet cable • Power adapter • Quick install guidePhysical Specifications• Dimensions: 8.57 x 5.81 x 1.37 in (217.74 x 147.73 x 34.92 mm)• Weight: 0.91 lb (0.41 kg)Warranty• Warranty localized to country of saleSupport• 24/7 basic technical phone support for 90 days from date of purchaseTechnical Specifications•W i-Fi transmitters/receivers (Tx/Rx)—3x3 (2.4 GHz) • External antenna—5dBi omni-directional • Supports Wireless Multimedia (WMM) based QoS • IPv6 Support (Internet Protocol Version 6)Standards• IEEE 802.11 b/g/n 2.4 GHz• F ive (5) 10/100 (1 WAN and 4 LAN) Fast Ethernet ports with auto-sensing technologySystem Requirements• B roadband (cable, DSL) Internet service and modem with Ethernet connection • 802.11 b/g/n 2.4 GHz wireless a dapter or Ethernet adapter and cable for each computer •M icrosoft ® Windows ® 7, 8, 8.1, Vista ®, XP, 2000, Mac ® OS, UNIX ®, or Linux ®•M icrosoft ® Internet Explorer ® 5.0, Firefox ® 2.0 or Safari ® 1.4 or higherSecurity• WiFi Protected Access ® (WPA/WPA2—PSK)• Double firewall protection (SPI and NAT firewall)• Denial-of-service (DoS) attack prevention • DMZ for secure gamingWNR2500。

工业级3G-4G无线路由器R50系列产品规格书

工业级3G-4G无线路由器R50系列产品规格书

R50 移动宽带 Router 技术规范
产品规格
无线参数 无线模块: 标准及频段: 工业级无线模块 FDD-LTE(Band1、2、4、5、7、8、12&17) TDD-LTE(Band38、Band39、Band40、Band41) HSPA(850/900/1900/2100MHz)/ GSM850/900/1800/1900MHz EV-DO(800MHz) 、TD-Scdma(Band34、Band39) HSUPA:5.76/7.2Mbps| HSPA+:5.76/21Mbps |FDD/TDD LTE:50/100Mbps <24dBm <-109dBm
标准版
● ● ○ ○ ● ○ ○ ○ ○ ● ○ ● ○ ○ R50-Wa2T
4G 版
● ● ● ● ○ ○ ● ○ ● ○ ○ R50-FA2T
单模双卡版
● ● ○ ○ ○ ● ○ ○ ○ ● ○ ● ○ R50-Wa2T-D
双模双卡版
● ● ○ ○ ● ○ ● ○ ○ ○ ○ ● ● ○ R50-WaE12T
R50 移动宽带 Router 技术规范
产品选型列表
R50
WAN LAN1-4 802.11n WIFI HSDPA HSUPA HSPA+ EV-DO TD-Scdma FDD-LTE TDD-LTE GPS RS232 RS485 Single Card Double Card 存储(2GB~32GB) 参考型号:
产品特点
工业级设计 采用高性能工业级无线模块 采用高性能工业级 32 位处理器 支持低功耗模式,包括休眠模式、定时上下线 模式和定时开关机模式 采用板金冷轧钢外壳 供电电源:+7.5V~32V DC(最大 36V) 防护等级:IP34(可处理到 IP51) 网络特性 端口流量检测 链路实时监控 多种 VPN 协议(PPTP、L2TP、IPSec、VPN) 串口 DTU 功能支持 支持按需拨号(语音、短信或者数据触发) 支持 UPnP 功能特性 向下兼容 GPRS 、 EDGE ;扩展支持 4G LTE 网络 支 持 1 WAN + 4 LAN , 提 供 标 准 RS-232 / RS-485 接口 支持 WIFI,支持 IEEE802.11b/g/n 支持有线网络和无线网络备份 支持硬件 WDT,提供防掉线机制,确保数据 终端永远在线 支持 PPTP、L2TP、GRE 多种 VPN 协议 支持 SNMP 管理协议 支持 WI-FI 强制广告推送功能 稳定可靠 采用软硬件看门狗及多级链路检测机制, 具备 故障自动检测、自动恢复能力,保证设备稳定 可靠运行 多重设备自检机制,确保链路畅通和告警 各接口 ESD 防护,防止静电冲击 具备无线网络信号指示灯, 分三级显示现场信 号强度 远程管理 远程参数配置 远程参数备份 远程重启和日志查询 远程设备升级 设备在线监控

NPort W2150A W2250A 系列无线串行设备服务器说明文档说明书

NPort W2150A W2250A 系列无线串行设备服务器说明文档说明书

NPort W2150A/W2250A系列1和2埠RS-232/422/485IEEE802.11a/b/g無線串列設備伺服器特色與優點•可將任何串列裝置連接至IEEE802.11a/b/g網路•透過內建乙太網路或WLAN執行Web-based設定•強化的區域網路、串列和電力突波保護•利用HTTPS和SSH強化遠端設定•透過WEP、WPA和WPA2保護存取資料的安全性•快速漫遊,可在存取點之間快速自動切換•具備離線埠緩衝和串列資料記錄功能•雙電源輸入(1螺旋式電源接頭、1端子台)認證簡介NPort®W2150A和W2250A是將串列和乙太網路裝置(例如PLC、儀表和感測器)連接到無線LAN的理想選擇。

您的通訊軟體將能夠透過無線LAN隨處存取串列裝置。

此外,無線裝置伺服器需要較少纜線,相當適合不便佈線的應用。

在基礎架構模式或Ad-Hoc模式中,NPort®W2150A和NPort®W2250A可以連接辦公室和工廠的Wi-Fi網路,以便使用者在多個AP(存取點)之間移動或漫遊,並且對於經常在不同的地點之間移動的裝置提供絕佳的解決方案。

規格Ethernet Interface10/100BaseT(X)Ports(RJ45connector)1Magnetic Isolation Protection 1.5kV(built-in)Standards IEEE802.3for10BaseTIEEE802.3u for100BaseT(X)Ethernet Software FeaturesConfiguration Options Web Console(HTTP/HTTPS),Windows UtilityManagement DHCP Option82,HTTP,IPv4,SMTP,SNMPv1/v2c/v3,Syslog,Telnet,Web Console Windows Real COM Drivers Windows95/98/ME/NT/2000,Windows XP/2003/Vista/2008/7/8/8.1/10(x86/x64),Windows2008R2/2012/2012R2/2016/2019(x64),Windows Embedded CE5.0/6.0,Windows XP EmbeddedLinux Real TTY Drivers Kernel versions:2.4.x,2.6.x,3.x,4.x,and5.xFixed TTY Drivers SCO UNIX,SCO OpenServer,UnixWare7,QNX4.25,QNX6,Solaris10,FreeBSD,AIX5.x,HP-UX11i,Mac OS XAndroid API Android3.1.x and laterMIB Device Settings MIB,RFC1213,RFC1317Security HTTPS/SSL,User Authentication Management:local database,RADIUS,SecureProtocols:HTTPS(TLSv1.2),SSH,SNMPv3,Cryptography:HMAC,SHA-1,SHA-256,SHA-384,RSA-1024,AES-128,AES-256Time Management NTP Client,SNTP ClientWLAN InterfaceWLAN Standards802.11a/b/g/nReceiver Sensitivity for802.11a(measured at5.680 GHz)Typ.-91@6Mbps Typ.-74@54MbpsReceiver Sensitivity for802.11b(measured at2.437 GHz)Typ.-92dBm@1Mbps Typ.-84dBm@11MbpsReceiver Sensitivity for802.11g(measured at2.437 GHz)Typ.-91dBm@6Mbps Typ.-73dBm@54MbpsReceiver Sensitivity for802.11n(2.4GHz;measured at2.437GHz)Typ.-89dBm@6.5Mbps(20MHz) Typ.-71dBm@72.2Mbps(20MHz)Receiver Sensitivity for802.11n(5GHz;measured at 5.680GHz)Typ.-89dBm@6.5Mbps(20MHz) Typ.-71dBm@72.2Mbps(20MHz) Typ.-85dBm@13.5Mbps(40MHz) Typ.-67dBm@150Mbps(40MHz)Modulation Type DSSSOFDMTransmission Distance Up to100meters(in open areas) Transmission Rate802.11a/g:54Mbps802.11b:11Mbps802.11n:6.5to150Mbps Transmitter Power for802.11b16±1.5dBm@1Mbps16±1.5dBm@11Mbps Transmitter Power for802.11g16±1.5dBm@6Mbps14±1.5dBm@54Mbps Transmitter Power for802.11a15±1.5dBm@6Mbps14±1.5dBm@54Mbps Transmitter Power for802.11n(2.4GHz)16dBm@1.5Mbps(6.5MHz)12dBm@1.5Mbps(72.2MHz) Transmitter Power for802.11n(5GHz)15dBm@1.5Mbps(6.5MHz)12dBm@1.5Mbps(150MHz) Frequency Band for CN(20MHz operating channels) 2.412to2.472GHz(13channels)5.180to5.240GHz(4channels)5.260to5.320GHz(4channels)15.745to5.825GHz(5channels) Frequency Band for EU(20MHz operating channels) 2.412to2.472GHz(13channels)5.180to5.240GHz(4channels)5.260to5.320GHz(4channels)15.500to5.700GHz(11channels)1 Frequency Band for JP(20MHz operating channels) 2.412to2.484GHz(14channels)5.180to5.240GHz(4channels)5.260to5.320GHz(4channels)15.500to5.700GHz(11channels)1 Frequency Band for US(20MHz operating channels) 2.412to2.462GHz(11channels)5.180to5.240GHz(4channels)5.260to5.320GHz(4channels)25.500to5.700GHz(11channels)25.745to5.825GHz(5channels)Wireless Security WEP encryption(64-bit and128-bit)WPA/WPA2-Enterprise(IEEE802.1X/RADIUS,TKIP,AES)WPA/WPA2-PersonalWLAN Modes Ad-hoc Mode,Infrastructure modeSerial InterfaceConnector DB9maleNo.of Ports NPort W2150A/W2150A-T:1NPort W2250A/W2250A-T:2Serial Standards RS-232,RS-422,RS-485Operation Modes Real COM mode,TCP Server mode,TCP Client mode,UDP mode,RFC2217mode,PairConnection mode,Ethernet Modem mode,DisabledBaudrate50bps to921.6kbpsData Bits5,6,7,8Stop Bits1,1.5,2Parity None,Even,Odd,Space,MarkFlow Control None,RTS/CTS,XON/XOFFRS-485Data Direction Control ADDC®(automatic data direction control)Pull High/Low Resistor for RS-4851kilo-ohm,150kilo-ohmsTerminator for RS-485120ohmsSurge1kVPhysical CharacteristicsHousing MetalInstallation Desktop,DIN-rail mounting(with optional kit),Wall mountingDimensions(with ears,without antenna)77x111x26mm(3.03x4.37x1.02in)Dimensions(without ears or antenna)100x111x26mm(3.94x4.37x1.02in)Weight NPort W2150A/W2150A-T:547g(1.21lb)NPort W2250A/W2250A-T:557g(1.23lb)Antenna Length109.79mm(4.32in)Environmental LimitsOperating Temperature Standard Models:0to55°C(32to131°F)Wide Temp.Models:-40to75°C(-40to167°F)Storage Temperature(package included)-40to75°C(-40to167°F)Ambient Relative Humidity5to95%(non-condensing)Power ParametersInput Current NPort W2150A/W2150A-T:179mA@12VDCNPort W2250A/W2250A-T:200mA@12VDCInput Voltage12to48VDCStandards and CertificationsEMC EN55032/24EMI CISPR32,FCC Part15B Class AEMS IEC61000-4-2ESD:Contact:4kV;Air:8kVIEC61000-4-3RS:80MHz to1GHz:3V/mIEC61000-4-4EFT:Power:2kV;Signal:2kVIEC61000-4-5Surge:Power:2kV;Signal:1kVIEC61000-4-6CS:150kHz to80MHz:3V/m;Signal:3V/mIEC61000-4-8PFMFIEC61000-4-11Radio Frequency CE(ETSI EN301893,ETSI EN300328,ETSI EN301489-17,ETSI EN301489-1),ARIBRCR STD-33,ARIB STD-66ReliabilityAlert Tools RTC(real-time clock)Automatic Reboot Trigger Built-in WDTMTBFTime NPort W2150A/W2150A-T:383,187hrsNPort W2250A/W2250A-T:363,327hrsStandards Telcordia(Bellcore)Standard TR/SRWarrantyWarranty Period5yearsDetails See /tw/warrantyPackage ContentsDevice1x NPort W2150A/W2250A Series device serverPower Supply1x power adapter,suitable for your region(standard temp.models only)Antenna1x2.4/5GHz antennaDocumentation1x quick installation guide1x warranty card尺寸訂購資訊Model Name No.of serial portsWLAN Channels Input Current Operating Temp.Power Adapter inBox Notes NPort W2150A-CN 1China bands 179mA @12VDC 0to 55°C Yes (CN plug)—NPort W2150A-EU 1Europe bands 179mA @12VDC 0to 55°C Yes (EU/UK/AUplug)—NPort W2150A-EU/KC 1Europe bands 179mA @12VDC 0to 55°C Yes (EU plug)KC certificateNPort W2150A-JP 1Japan bands 179mA @12VDC 0to 55°C Yes (JP plug)—NPort W2150A-US 1US bands 179mA @12VDC 0to 55°C Yes (US plug)—NPort W2150A-T-CN 1China bands 179mA @12VDC -40to 75°C No —NPort W2150A-T-EU 1Europe bands 179mA @12VDC -40to 75°C No —NPort W2150A-T-JP 1Japan bands 179mA @12VDC -40to 75°C No —NPort W2150A-T-US 1US bands 179mA @12VDC -40to 75°C No —NPort W2250A-CN 2China bands 200mA @12VDC 0to 55°C Yes (CN plug)—NPort W2250A-EU 2Europe bands 200mA @12VDC 0to 55°C Yes (EU/UK/AUplug)—NPort W2250A-EU/KC 2Europe bands 200mA @12VDC 0to 55°C Yes (EU plug)KC certificateNPort W2250A-JP 2Japan bands 200mA @12VDC 0to 55°C Yes (JP plug)—NPort W2250A-US 2US bands 200mA @12VDC 0to 55°C Yes (US plug)—NPort W2250A-T-CN 2China bands 200mA @12VDC -40to 75°C No —NPort W2250A-T-EU 2Europe bands 200mA @12VDC -40to 75°C No —NPort W2250A-T-JP 2Japan bands 200mA @12VDC -40to 75°C No —NPort W2250A-T-US2US bands200mA @12VDC-40to 75°CNo—配件(選購)AntennasANT-WDB-ARM-02 2.4/5GHz,omni-directional rubber duck antenna,2dBi,RP-SMA(male)CablesCBL-F9M9-150DB9female to DB9male serial cable,1.5mCBL-F9M9-20DB9female to DB9male serial cable,20cmConnectorsADP-RJ458P-DB9F DB9female to RJ45connectorMini DB9F-to-TB DB9female to terminal block connectorDIN-Rail Mounting KitsDK35A DIN-rail mounting kit,35mmPower AdaptersPWR-12050-WPAU-S1Locking barrel plug,12VDC,0.5A,100-240VAC,Australia(AU)plug,0to40°C operating temperature PWR-12050-WPCN-S1Locking barrel plug,12VDC,0.5A,100to240VAC,China(CN)plug,0to40°C operating temperature PWR-12050-WPEU-S1Locking barrel plug,12VDC,0.5A,100-240VAC,Continental Europe(EU)plug,0to40°C operatingtemperaturePWR-12050-WPUK-S1Locking barrel plug,12VDC,0.5A,100-240VAC,United Kingdom(UK)plug,0to40°C operatingtemperaturePWR-12050-WPUSJP-S1Locking barrel plug,12VDC,0.5A,100-240VAC,United States/Japan(US/JP)plug,0to40°C operatingtemperaturePWR-12150-AU-SA-T Locking barrel plug,12VDC,1.5A,100-240VAC,Australia(AU)plug,-40to75°C operating temperatureApplicable Models:NPort W2150A-TNPort W2250A-TPWR-12150-CN-SA-T Wide-temperature(-40to75°C)locking barrel plug,12VDC,1.5A,100to240VAC,China(CN)plugApplicable Models:NPort W2150A-TNPort W2250A-TPWR-12150-EU-SA-T Locking barrel plug,12VDC,1.5A,100-240VAC,Continental Europe(EU)plug,-40to75°C operatingtemperatureApplicable Models:NPort W2150A-TNPort W2250A-TPWR-12150-UK-SA-T Locking barrel plug,12VDC,1.5A,100-240VAC,United Kingdom(UK)plug,-40to75°C operatingtemperatureApplicable Models:NPort W2150A-TNPort W2250A-TPWR-12150-USJP-SA-T Locking barrel plug,12VDC1.5A,100-240VAC,United States/Japan(US/JP)plug,-40to75°Coperating temperatureApplicable Models:NPort W2150A-TNPort W2250A-TPower CordsCBL-PJ21NOPEN-BK-30Locking barrel plug to bare-wire cable©Moxa Inc.版權所有.2021年1月25日更新。

Phoenix Contact 产品说明书:UT 2,5 YE 线路通透电阻块 3045059

Phoenix Contact 产品说明书:UT 2,5 YE 线路通透电阻块 3045059

21/01/2016 Page 1 / 19Feed-through terminal block - UT 2,5 YE - 3045059Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (/download)Feed-through terminal block, Connection method: Screw connection, Cross section: 0.14 mm² - 4 mm²,AWG: 26 - 12, Width: 5.2 mm, Color: yellow, Mounting type: NS 35/7,5, NS 35/15The illustration shows the color versionKey Commercial DataTechnical dataGeneralFeed-through terminal block - UT 2,5 YE - 3045059Technical dataGeneralDimensionsConnection data21/01/2016 Page 2 / 19Feed-through terminal block - UT 2,5 YE - 3045059Technical dataConnection dataStandards and RegulationsClassificationseCl@ssETIMUNSPSCApprovalsApprovals21/01/2016 Page 3 / 19Feed-through terminal block - UT 2,5 YE - 3045059ApprovalsApprovalsCSA / UL Recognized / VDE Gutachten mit Fertigungsüberwachung / cUL Recognized / DNV / IECEE CB Scheme / EAC / RS / cULus RecognizedEx ApprovalsIECEx / ATEX / UL Recognized / cUL Recognized / EAC Ex / cULus RecognizedApprovals submittedApproval detailsUL RecognizedcUL Recognized21/01/2016 Page 4 / 1921/01/2016 Page 5 / 19Feed-through terminal block - UT 2,5 YE - 3045059ApprovalsDNVIECEE CB SchemeEACRScULus RecognizedAccessoriesAccessories DIN railDIN rail perforated - NS 35/ 7,5 PERF 2000MM - 0801733DIN rail, material: steel galvanized and passivated with a thick layer, perforated, height 7.5 mm, width 35 mm, length:2000 mmDIN rail, unperforated - NS 35/ 7,5 UNPERF 2000MM - 0801681DIN rail, material: Steel, unperforated, height 7.5 mm, width 35 mm, length: 2 m21/01/2016 Page 6 / 19Feed-through terminal block - UT 2,5 YE - 3045059AccessoriesDIN rail perforated - NS 35/ 7,5 WH PERF 2000MM - 1204119DIN rail 35 mm (NS 35)DIN rail - NS 35/ 7,5 WH UNPERF 2000MM - 1204122DIN rail 35 mm (NS 35)DIN rail, unperforated - NS 35/ 7,5 AL UNPERF 2000MM - 0801704DIN rail, unperforated, Width: 35 mm, Height: 7.5 mm, Length: 2000 mm, Color: silverDIN rail perforated - NS 35/ 7,5 ZN PERF 2000MM - 1206421DIN rail, material: Galvanized, perforated, height 7.5 mm, width 35 mm, length: 2 mDIN rail, unperforated - NS 35/ 7,5 ZN UNPERF 2000MM - 1206434DIN rail, material: Galvanized, unperforated, height 7.5 mm, width 35 mm, length: 2 m21/01/2016 Page 7 / 19Feed-through terminal block - UT 2,5 YE - 3045059AccessoriesDIN rail, unperforated - NS 35/ 7,5 CU UNPERF 2000MM - 0801762DIN rail, material: Copper, unperforated, height 7.5 mm, width 35 mm, length: 2 mEnd cap - NS 35/ 7,5 CAP - 1206560DIN rail end piece, for DIN rail NS 35/7.5DIN rail perforated - NS 35/15 PERF 2000MM - 1201730DIN rail, material: steel galvanized and passivated with a thick layer, perforated, height 15 mm, width 35 mm, length:2000 mmDIN rail, unperforated - NS 35/15 UNPERF 2000MM - 1201714DIN rail, material: Steel, unperforated, height 15 mm, width 35 mm, length: 2 mDIN rail perforated - NS 35/15 WH PERF 2000MM - 0806602DIN rail 35 mm (NS 35)21/01/2016 Page 8 / 19Feed-through terminal block - UT 2,5 YE - 3045059AccessoriesDIN rail - NS 35/15 WH UNPERF 2000MM - 1204135DIN rail 35 mm (NS 35)DIN rail, unperforated - NS 35/15 AL UNPERF 2000MM - 1201756DIN rail, deep drawn, high profile, unperforated, 1.5 mm thick, material: aluminum, height 15 mm, width 35 mm,length 2000 mmDIN rail perforated - NS 35/15 ZN PERF 2000MM - 1206599DIN rail, material: Galvanized, perforated, height 15 mm, width 35 mm, length: 2 mDIN rail, unperforated - NS 35/15 ZN UNPERF 2000MM - 1206586DIN rail, material: Galvanized, unperforated, height 15 mm, width 35 mm, length: 2 mDIN rail, unperforated - NS 35/15 CU UNPERF 2000MM - 1201895DIN rail, material: Copper, unperforated, 1.5 mm thick, height 15 mm, width 35 mm, length: 2 m21/01/2016 Page 9 / 19Feed-through terminal block - UT 2,5 YE - 3045059AccessoriesEnd cap - NS 35/15 CAP - 1206573DIN rail end piece, for DIN rail NS 35/15DIN rail, unperforated - NS 35/15-2,3 UNPERF 2000MM - 1201798DIN rail, material: Steel, unperforated, 2.3 mm thick, height 15 mm, width 35 mm, length: 2 mEnd blockEnd clamp - CLIPFIX 35 - 3022218Quick mounting end clamp for NS 35/7,5 DIN rail or NS 35/15 DIN rail, with marking option, width: 9.5 mm, color:grayEnd clamp - CLIPFIX 35-5 - 3022276Quick mounting end clamp for NS 35/7,5 DIN rail or NS 35/15 DIN rail, with marking option, with parking option for FBS...5, FBS...6, KSS 5, KSS 6, width: 5.15 mm, color: grayEnd clamp - E/NS 35 N - 0800886End clamp, width: 9.5 mm, color: grayEnd cover21/01/2016 Page 10 / 19Feed-through terminal block - UT 2,5 YE - 3045059AccessoriesEnd cover - D-UT 2,5/10 - 3047028End cover, Length: 47.7 mm, Width: 2.2 mm, Height: 48.4 mm, Color: grayEnd cover - D-UT 2,5/10 YE - 3047248End cover, Length: 48 mm, Width: 2.2 mm, Height: 48.4 mm, Color: yellowInsulating sleeveInsulating sleeve - MPS-IH WH - 0201663Insulating sleeve, Color: whiteInsulating sleeve - MPS-IH RD - 0201676Insulating sleeve, Color: redInsulating sleeve - MPS-IH BU - 0201689Insulating sleeve, Color: blue21/01/2016 Page 11 / 19Feed-through terminal block - UT 2,5 YE - 3045059AccessoriesInsulating sleeve - MPS-IH YE - 0201692Insulating sleeve, Color: yellowInsulating sleeve - MPS-IH GN - 0201702Insulating sleeve, Color: greenInsulating sleeve - MPS-IH GY - 0201728Insulating sleeve, Color: grayInsulating sleeve - MPS-IH BK - 0201731Insulating sleeve, Color: blackJumperPlug-in bridge - FBS 2-5 - 3030161Plug-in bridge, Length: 22.7 mm, Width: 9 mm, Number of positions: 2, Color: red21/01/2016 Page 12 / 19Feed-through terminal block - UT 2,5 YE - 3045059AccessoriesPlug-in bridge - FBS 3-5 - 3030174Plug-in bridge, Length: 22.7 mm, Width: 14.2 mm, Number of positions: 3, Color: redPlug-in bridge - FBS 4-5 - 3030187Plug-in bridge, Length: 22.7 mm, Width: 19.4 mm, Number of positions: 4, Color: redPlug-in bridge - FBS 5-5 - 3030190Plug-in bridge, Length: 22.7 mm, Width: 24.6 mm, Number of positions: 5, Color: redPlug-in bridge - FBS 10-5 - 3030213Plug-in bridge, Length: 22.7 mm, Width: 50.6 mm, Number of positions: 10, Color: redPlug-in bridge - FBS 20-5 - 3030226Plug-in bridge, Number of positions: 20, Color: red21/01/2016 Page 13 / 19Feed-through terminal block - UT 2,5 YE - 3045059AccessoriesPlug-in bridge - FBS 50-5 - 3038930Plug-in bridge, Number of positions: 50, Color: redPlug-in bridge - FBSR 2-5 - 3033702Plug-in bridge, Number of positions: 2, Color: redPlug-in bridge - FBSR 3-5 - 3001591Plug-in bridge, Number of positions: 3, Color: redPlug-in bridge - FBSR 4-5 - 3001592Plug-in bridge, Number of positions: 4, Color: redPlug-in bridge - FBSR 5-5 - 3001593Plug-in bridge, Number of positions: 5, Color: red21/01/2016 Page 14 / 19Feed-through terminal block - UT 2,5 YE - 3045059AccessoriesPlug-in bridge - FBSR 10-5 - 3033710Plug-in bridge, Number of positions: 10, Color: redLabeled terminal markerZack marker strip - ZB 5 CUS - 0824962Zack marker strip, can be ordered: Strip, white, labeled according to customer specifications, Mounting type: Snap into tall marker groove, for terminal block width: 5.2 mm, Lettering field: 5.15 x 10.5 mmZack marker strip - ZB 5,LGS:FORTL.ZAHLEN - 1050017Zack marker strip, Strip, white, labeled, Printed horizontally: Consecutive numbers 1 - 10, 11 - 20, etc. up to 491 -500, Mounting type: Snap into tall marker groove, for terminal block width: 5.2 mm, Lettering field: 5.15 x 10.5 mmZack marker strip - ZB 5,QR:FORTL.ZAHLEN - 1050020Zack marker strip, Strip, white, labeled, can be labeled with: Plotter, Printed vertically: Consecutive numbers 1 - 10,11 - 20, etc. up to 491 - 500, Mounting type: Snap into tall marker groove, for terminal block width: 5.2 mm, Lettering field: 5.15 x 10.5 mmZack marker strip - ZB 5,LGS:GLEICHE ZAHLEN - 1050033Zack marker strip, Strip, white, labeled, can be labeled with: Plotter, Printed horizontally: Identical numbers 1 or 2,etc. up to 100, Mounting type: Snap into tall marker groove, for terminal block width: 5.2 mm, Lettering field: 5.15 x 10.5 mm21/01/2016 Page 15 / 19Feed-through terminal block - UT 2,5 YE - 3045059AccessoriesMarker for terminal blocks - ZB 5,LGS:L1-N,PE - 1050415Marker for terminal blocks, Strip, white, labeled, Horizontal: L1, L2, L3, N, PE, L1, L2, L3, N, PE, Mounting type: Snap into tall marker groove, for terminal block width: 5.2 mm, Lettering field: 5.15 x 10.5 mmMarker for terminal blocks - UC-TM 5 CUS - 0824581Marker for terminal blocks, can be ordered: by sheet, white, labeled according to customer specifications, Mounting type: Snap into tall marker groove, for terminal block width: 5.2 mm, Lettering field: 10.5 x 4.6 mmMarker for terminal blocks - UCT-TM 5 CUS - 0829595Marker for terminal blocks, can be ordered: by sheet, white, labeled according to customer specifications, Mounting type: Snap into tall marker groove, Lettering field: 4.6 x 10.5 mmMarker penMarker pen - X-PEN 0,35 - 0811228Marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line thickness 0.35mmPartition platePartition plate - ATP-UT - 3047167Partition plate, Length: 50 mm, Width: 2.2 mm, Height: 48 mm, Color: gray21/01/2016 Page 16 / 19Feed-through terminal block - UT 2,5 YE - 3045059AccessoriesSpacer plate - DP PS-5 - 3036725Spacer plate, Length: 22.4 mm, Width: 5.2 mm, Height: 29 mm, Number of positions: 1, Color: redScrewdriver toolsScrewdriver - SZS 0,6X3,5 - 1205053Actuation tool, for ST terminal blocks, insulated, also suitable for use as a bladed screwdriver, size: 0.6 x 3.5 x 100mm, 2-component grip, with non-slip gripTerminal markingZack marker strip - ZB 5 :UNBEDRUCKT - 1050004Zack marker strip, Strip, white, unlabeled, can be labeled with: Plotter, Mounting type: Snap into tall marker groove,for terminal block width: 5.2 mm, Lettering field: 5.1 x 10.5 mmMarker for terminal blocks - UC-TM 5 - 0818108Marker for terminal blocks, Sheet, white, unlabeled, can be labeled with: BLUEMARK CLED, BLUEMARK LED,Mounting type: Snap into tall marker groove, for terminal block width: 5.2 mm, Lettering field: 10.5 x 4.6 mmMarker for terminal blocks - UCT-TM 5 - 0828734Marker for terminal blocks, Sheet, white, unlabeled, can be labeled with: THERMOMARK CARD, BLUEMARK CLED,BLUEMARK LED, TOPMARK LASER, Mounting type: Snap into tall marker groove, for terminal block width: 5.2 mm,Lettering field: 4.6 x 10.5 mmTest plug terminal block21/01/2016 Page 17 / 19Feed-through terminal block - UT 2,5 YE - 3045059AccessoriesTest plugs - MPS-MT - 0201744Test plugs, Color: silverTest plugs - PS-5 - 3030983Test plugs, Color: redTest plugs - PS-5/2,3MM RD - 3038723Test plugs, Color: redTest socketTest adapter - PAI-4-FIX-5/6 BU - 30359754 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitchTest adapter - PAI-4-FIX-5/6 OG - 30359744 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitch21/01/2016 Page 18 / 19Feed-through terminal block - UT 2,5 YE - 3045059AccessoriesTest adapter - PAI-4-FIX-5/6 YE - 30359774 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitchTest adapter - PAI-4-FIX-5/6 RD - 30359764 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitchTest adapter - PAI-4-FIX-5/6 GN - 30359784 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitchTest adapter - PAI-4-FIX-5/6 BK - 30359804 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitchTest adapter - PAI-4-FIX-5/6 GY - 30359824 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitch21/01/2016 Page 19 / 19Feed-through terminal block - UT 2,5 YE - 3045059AccessoriesTest adapter - PAI-4-FIX-5/6 VT - 30359794 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitchTest adapter - PAI-4-FIX-5/6 BN - 30359814 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitchTest adapter - PAI-4-FIX-5/6 WH - 30359834 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitchTest adapter - PAI-4-N GY - 30328714 mm test adapter, for terminal blocks with 5.2 mm, 6.2 mm and 8.2 mm pitchDrawingsCircuit diagramPhoenix Contact 2016 © - all rights reserved 。

NACEN220K354x5.5TR13F中文资料

NACEN220K354x5.5TR13F中文资料

9®NIC COMPONENTS CORP. ww www www www Surface Mount Aluminum Electrolytic Capacitors NACEN Series FEATURES•CYLINDRICAL V-CHIP CONSTRUCTION FOR SURFACE MOUNTI •NON-POLARIZED, 2000 HOURS A T 85O C •5.5mm HEIGHT•ANTI-SOLVENT (2 MINUTES)•DESIGNED FOR REFLOW SOLDERING CHARACTERISTICS MAXIMUM PERMISSIBLE RIPPLE CURRENT (mA rms AT 120Hz AND 85O C)STANDARD PRODUCT AND CASE SIZE TABLE DXL (mm)*Denotes values available in optional 10% toleranceUNTINGRoHSCompliantincludes all homogeneous materials*See Part Number System for DetailsNACEN 100 M 16V 5x5.5 TR 13 F RoHS Compliant 97% Sn (min.), 3% Bi (max.) 330mm (13”) Reel Tape & Reel Size in mm Working Voltage T olerance Code M=20%, K=10% Capacitance Code in µF , fi rst 2 digits are signifi cant Third digit is no. of zeros, “R” indicates decimal for values under 10µF Series PART NUMBER SYSTEM 0.3mm max.D φLI I WPABDIMENSIONS (mm)Case Size D φ±0.5L max.A/B±0.2I ± 0.2W P±0.24x5.5 4.0 5.5 4.3 1.80.5 ~ 0.8 1.05x5.5 5.0 5.5 5.3 2.10.5 ~ 0.8 1.46.3x5.5 6.3 5.5 6.6 2.50.5 ~ 0.8 2.2PRECAUTIONS Please review the notes on correct use, safety and precautions found on pages T10 & T11 of NIC’s Electrolytic Capacitor catalog .Also found at /precautionsIf in doubt or uncertainty, please review your specifi c application - process details withNIC’s technical support personnel: tpmg@Rated Voltage Rating 6.3 ~ 50VdcRated Capacitance Range 0.1 ~ 47µFOperating Temperature Range -40° ~ +85°CCapacitance Tolerance ±20%(M), ±10%(K)*Max. Leakage Current After 1 Minutes at 20°C 0.03CV +6µA maximumMax. Tan δ @ 120Hz/20°C W.V . (Vdc) 6.31016253550Tan δ @ 120Hz/20°C 0.240.200.170.170.150.15Low Temperature Stability (Impedance Ratio @ 120Hz)W.V . (Vdc) 6.31016253550Z-40°C/Z +20°C 432222Z-40°C/Z +20°C 884433Load Life T est at Rated W.V .85°C 2,000 Hours (Reverse polarity every 500 hours)Capacitance Change Within ±25% of initial measured valueTan δLess than 200% of specifi ed value Leakage Current Less than specifi ed valueCap.(µF)Code Working Voltage (Vdc)6.310162535500.1R10-----4x5.50.22R22-----4x5.50.33R33-----4x5.5*0.47R47-----4x5.51.01R0-----4x5.5*2.22R2----4x5.5*5x5.5*3.33R3---4x5.5*5x5.5*5x5.5*4.74R7--4x5.55x5.5*5x5.5*6.3x5.510100-4x5.5*5x5.5* 6.3x5.5* 6.3x5.5* 6.3x5.5*222205x5.5* 6.3x5.5* 6.3x5.5*---33330 6.3x5.5* 6.3x5.5* 6.3x5.5*---47470 6.3x5.5*-----Cap. (µF)Working Voltage (Vdc)6.310162535500.1----- 1.00.22----- 2.30.33----- 3.50.47----- 5.01.0-----102.2----8.4153.3---1017184.7--1219202310-172528302322313539---33394357---4747-----元器件交易网。

CN05, CN10 SERIES非弹簧返回直连辅助调节器产品数据说明书

CN05, CN10 SERIES非弹簧返回直连辅助调节器产品数据说明书

CN05, CN10 SERIESNON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND TWO-POSITION CONTROLPRODUCT DATAGENERALThis non-spring return direct-coupled damper actuatorprovides floating and two-position control for:• air dampers,• VAV units,• air handlers,• ventilation flaps,• louvers, and• reliable control for air damper applications with up to 10sq ft / 44 lb-in. (5 Nm) and 20 sq ft / 88 lb-in. (10 Nm)(seal- less damper blades; air friction-dependent).FEATURES• Declutch for manual adjustment• Adjustable mechanical end limits• Removable access cover for direct wiring• Mountable in any orientation• Rotation direction and service/OFF switchSPECIFICATIONSSupply voltageCN6105/CN6110 24 Vac/dc -15%/+20%, 50/60 HzCN4605/CN4610 230 Vac -15%/+20%, 50/60 HzNominal voltageCN6105/CN6110 24 Vac/dc, 50/60 HzCN4605/CN4610 230Vac, 50/60 HzAll values stated hereinafter apply to operation undernominal voltage conditions.Power consumptionCN6105/CN6110 5 VA / 2 WCN4605 22 VA / 2 W at 50 HzCN4610 25 VA / 2 W at 60 HzAmbient limitsAmbient operating limits -5...+140 °F (20...+60 °C)Ambient storage limits -22...+176 °F (-30...+80 °C)Relative humidity 5...95%, non-condensingSafetyProtection standard IP54Protection class II as per EN 60730-1Overvoltage category IILifetimeFull strokes 60000Repositions 1.5millionMountingRound damper shaft 3/8 in…5/8 in.Square damper shaft 1/4 in…1/2 in.; 45° stepsShaft length min. 1-5/8 in.End switches (when included)Rating ClassIITriggering points 5° / 85°Torque rating44 lb-in. (5Nm) / 88 lb-in. (10 Nm)Runtime for 90°CN6105 90 sec (dc / 60 Hz ac)CN6110 90 sec (dc / 50 Hz ac)CN4605 65…110 s (60/50 Hz)CN4610 65…140 s (60/50 Hz)Rotation stroke 95°+ 3°Dimensions see “Dimensions” on page 6Weight (without cables) 1 lbs.Noise rating 35 dB(A) max. at 1 m40 dB(A) for 230 Vac at65 sec runtimeCertificationCN6105/CN6110 CE & ULCN4605/CN4610 CECN0B-0544CH33 R0805B12PRODUCT IDENTIFICATION SYSTEMC N 75 10 A 2 0 XXBASIC FEATURESFig. 1. Setting units and control elementsLegend for Fig. 1:1) Universal shaft adapter2) Mechanical end limits (manually adjustable) 3) Declutch button4) Function selection switch 5) Removable access cover 6) Anti-rotation bracketContents of PackageThe delivery package includes the actuator, parts 1 through 6 (see Fig. 1), plus two cable grommets and a spare cable grommet.RUN MODESThe function selection switch (see Fig. 2) can be used to place the actuator into any one of two different modes: • Service/Off; or• the floating/2-position run mode (“Dir” for CCW-closing dampers or “Rev” for CW-closing dampers).Fig. 2. Function selection switchPower-Off BehaviorIf power is removed, the shaft adapter remains in position.Service/OffIf the function selection switch is set to the “Service/Off” position, then all rotary movement is cancelled, and all control signals are ignored, thus allowing the actuator to be manually operated safely.Model Description CN6105A1011 5Nm, 24Vac/Vdc, floating control, non-spring return, no feedback and without aux. Switch CN4605A10015Nm, 230Vac, floating control, non-springreturn, no feedback and without aux. Switch CN6110A100310Nm, 24Vac/Vdc, floating control, non-springreturn, no feedback and without aux. Switch CN6110A1201 10Nm, 24Vac/Vdc, floating control, non-spring return, no feedback and with aux. Switch CN4610A1001 10Nm, 230Vac, floating control, non-spring return, no feedback and without aux. SwitchCN05,CN10 SERIES DAMPER ACTUATORS FOR FLOATING/2-POSITON CONTROL CN0B-0544CH33 R0805B3Floating/2-Position Run ModeIf the function selection switch has been set to one of the two floating/2-position control settings—and if the actuator is wired correspondingly (see Fig. 7, Fig. 8, and Fig. 9)—then as soon as operating power is applied, the shaft adapter will run according to the control signals applied.Table 1 describes the behavior (“stops,” rotates “CCW,” or rotates “CW”) of the CN6105/CN6110 in dependence upon the control signals (switch “open” or “24 Vac/dc”) applied to terminals 3 and 4, the function selection switch setting, and the manner in which the actuator is wired (either for floating mode: see Fig. 7; or for 2-position mode: see Fig. 8).Table 1. Behavior of CN6105/CN6110wiring control signal at switch settingterm 3term 4Dir Service/ OffRevfloat. open open stops stops stops open 24Vac/dc CCW stops CW24Vac/dc open CW stops CCW2-pos. 24Vac/dc open CWstops CCW24Vac/dc 24Vac/dcCCW stopsCWTable 2 describes the behavior (“stops,” rotates “CCW,” or rotates “CW”) of the CN4605/CN4610 in dependence upon the control signals (switch “open” or “230 Vac”) applied to terminals 1 and 3 and the function selection switch setting: only one manner of wiring is permitted (see Fig. 9). Table 2. Behavior of CN4605/CN4610control signal at switch setting term 1term 3DirService/ OffRevopen open stops stops stops open 230 Vac stops stops stops 230 Vac open CW stops CCW 230 Vac 230 VacCCWstopsCWMANUAL ADJUSTMENTIMPORTANTTo prevent equipment damage, before manualadjustment, you must remove power or set the func-tion selection switch to the “Service/Off” position. After removing power or setting the function selection switch to the “Service/Off” position, the gear train can be disengaged using the declutch button, permitting the shaft adapter to be manually rotated to any position.Limitation of Rotation StrokeTwo adjustable mechanical end limits are provided to limit the angle of rotation as desired (see Fig. 3). The mechanical end limits must be securely fastened in place.Fig.3. Mechanical end limitsTo ensure tight closing of the dampers, the shaft adapter has atotal rotation stroke of 95°.INTERNAL END SWITCHESThe internal end switches “A” and “B” are changeover switches which are activated when the shaft adapter moves past a position of 5° and 85°, respectively (see also Table 5).Fig.4. Internal end switch triggering pointsCN0B-0544CH33 R0805BCN05,CN10 SERIES DAMPER ACTUATORS FOR FLOATING/2-POSITON CONTROLINSTALLATIONTo avoid personal injury (electrical shock) and toprevent equipment damage, before installation, youmust remove power.These actuators are designed for single-point mounting. Mounting InstructionsAll information and steps are included in the Installation Instructions supplied with each actuator.Mounting PositionThe actuators can be mounted in any position (IP54 is dependent upon orientation; see Fig. 5). Choose a mounting pKosition permitting easy access to cables and controls.Fig. 5. Mounting for IP54NOTE: Further, in order to guarantee IP54, only originalHoneywell grommets may be used.Anti-Rotation Bracket and ScrewsIf the actuator is to be mounted directly on a damper shaft, use the anti-rotation bracket and screws included in the delivery package. The min. distance between the center of the damper shaft and the middle of the anti-rotation bracket is 3.35 in.; a max. of 4.25 in. is allowed (see also Fig 11).Depending upon the specifics of your mounting site, the actuator may shift in position slightly while tightening the screws at the top of the shaft adapter. The anti-rotation bracket features a T-piece with a 5-mm-long shank to accommodate for this movement. It is important to ensure that this play is not impeded. Universal Shaft AdapterThe universal shaft adapter can be used for shafts of various diameters and shapes (round: 3/8...5/8 in. and square:1/4...1/2 in.).WIRINGTo avoid personal injury (electrical shock) and toprevent equipment damage, before wiring, youmust remove power.Access CoverIMPORTANTOnce the access cover has been removed, pleasetake care to avoid damaging any of the parts nowaccessible.The access cover can be unscrewed and removed in order to gain access to the terminal block(s) and perform wiring.Fig. 6. Access CoverWiring DiagramsFig. 7. CN6105/CN6110 (floating mode)CN0B-0544CH33 R0805BCN05,CN10 SERIES DAMPER ACTUATORS FOR FLOATING/2-POSITON CONTROL45Fig. 8. CN6105/CN6110 (2-position mode)Fig. 9. CN4605/CN4610 (2-position mode)Fig. 10. End switchesNOTE: Both internal end switches must be connected to thesame power source.Tables 3,4 and 5 summarize the information presented in the preceding wiring diagrams.Table 3. Signals at terminals for CN6105/CN6110 ter- minal signal in floatingsignal in 2-pos. mode2common ~/- common ~/- 324 V ~/+ (control signal) 24 V ~/+ (control/ power signal) 424 V ~/+ (control signal) 24 V ~/+ (control signal/power)NOTE: All cables connected to these terminals must beequipped with spark suppression.Table 4. Signals at terminals for CN4605/CN4610 terminalsignal 1L (230 V ~) 2N (230 V ~)3 control signalNOTE: All cables connected to these terminals must beequipped with spark suppression.Table 5. Internal end switches (SSW2)terminaltype of switchS1 common lead for switches A and BS2 / S3change-over switch A (S1/S2 opens and S1/S3 closes when shaft adapter moves CW past 5°; reverts to original state when shaft adapter moves CCW past 5°).S5 / S6change-over switch B (S1/S5 opens and S1/S6 closes when shaft adapter moves CW past 85°; reverts to original state when shaft adapter moves CCW past 85°).CN0B-0544CH33 R0805BCN05,CN10 SERIES DAMPER ACTUATORS FOR FLOATING/2-POSITON CONTROL6DIMENSIONSFig. 11. Dimensions (in in.)Automation and Control SolutionsHoneywell International Inc. Honeywell (Tianjin) Limited 1985 Douglas Drive North 66, BaiHe Road, TEDAGolden Valley, MN 55422 Tianjin, 300457,P.R.C.Printed in China. on recycled paper containing at least 10% post-consumer paper fibers.CN05,CN10 SERIES DAMPER ACTUATORS FOR FLOATING/2-POSITON CONTROLCN0B-0544CH33 R0805B。

赛斯纳152手册(中文版)

赛斯纳152手册(中文版)

赛斯纳152第一节总论简介本手册有九节内容,包括民航规章/条例第三部分中要求提供给飞行员的材料和赛斯纳公司提供的补充资料。

第一节提供了一些基本数据和使用者广泛关注的信息,同时还包括一些符号、缩写和常用术语的定义或解释。

描述性资料发动机发动机数:1发动机生产厂家:Avco Lycoming发动机型号:O-235-L2C发动机种类:正常进气、直接驱动、气冷式、水平队列式、配备化油器、233.3立方英寸排量的四气缸发动机。

马力等级和发动机速度:2550转每分下110额定制动马力.螺旋桨螺旋桨生产厂家:McCauley 零件公司螺旋桨模型数:1A103/TCM6958桨叶数:2螺旋桨直径:最大直径:69英寸最小直径:67.5英寸螺旋桨类型:固定桨距燃油认可的燃油等级(及颜色):100低铅航空燃油(蓝色)100(以前100/130)等级航空燃油(绿色)燃油容量:标准油箱总容量:26加仑每箱总容量:13加仑总可用燃油:24.5加仑远程油箱总容量:39加仑每箱总容量:19.5加仑总可用燃油:37.5加仑注:由于在油箱间可以交叉输油,每次注油后应重新灌满油箱以保证最大容量。

滑油滑油等级(规格):MIL-L-6082 航空等级中的纯矿物滑油用于最初25小时和首次飞行25小时换油时的补充供给。

飞机飞行50小时或消耗稳定前可继续使用。

注意飞机出厂交付使用时配有发动机防腐滑油,应在首次操作25小时后消耗完毕。

MIL-L-22851 无烟稀释滑油应在飞机飞行50小时后或消耗稳定后使用。

温度范围内的建议黏度:MIL-L-6082航空等级中的纯矿物滑油16℃(60℉)以上 SAE:50-1℃--32℃之间(30℉--90℉) SAE:40-18℃--21℃之间(0℉--70℉) SAE:30-12℃(10℉)以下 SAE:20MIL-L—22851无烟稀释滑油16℃(60℉)以上 SAE:40或50-1℃--32℃之间(30℉--90℉) SAE:40-18℃--21℃之间(0℉--70℉) SAE:30-12℃(10℉)以下 SAE:30滑油容量:集油槽:6夸脱总量:7夸脱(如果滑油过滤器已安装)最大允许重量:停机重量:1675磅起飞重量:1670磅降落重量:1670磅行李间重量:第一行李区(或在儿童座席)站位为50至76,120磅。

埃尔克斯电子产品的五种型号功能规范说明书

埃尔克斯电子产品的五种型号功能规范说明书

SPECIFICATIONS13Models 7520DT, 7530DT, 7540DT, 7550DT and 7564SAFunctional SpecificationsINPUTVoltage 115/230 VAC 15, Single Phase, User selection Frequency 50/60 Hz 5Fuse6.3 Amp 250V Slo-Blo for 7550DT and 7564SA 5 Amp 250V Slo-Blo for 75/20/30/40DTDIELECTRIC WITHSTAND TEST MODEOutput Rating5 KV @ 40 mA for 7550DT and 7564SA, 5 KV @ 20mA for 75/20/30/40DT6 KV @ 10 mA DC for 75/30/40/50DT and 7564SAOutput AdjustmentRange:0 - 5 KV AC 0 - 6 KV DCResolution: 1 volt/step Accuracy:(2 of setting 5 volts) Ramp-HI 12mA peak maximum, ON/OFF selectableCharge-LORange:0.0 - 350.0A DC or Auto setHI-Limit AC Range:0.00 - 40.00 mA for 7550DT and 7564SA, 0.00 - 20.00 mA for 75/20/30/40DT Resolution: 0.01 mA/step Accuracy: (2 of setting 2 counts) DC Range:0 - 9999AResolution: 1A/stepAccuracy:(2 of setting 2 counts) LO-Limit AC Range:0.000 - 9.999 mA Resolution: 0.001 mA/stepAccuracy: (2 of setting 2 counts) DC Range:0.0 - 999.9 AResolution: 0.1A/stepAccuracy:(2 of setting 2 counts) Arc Detection Range:1 - 9Failure DetectorAudible and VisualRecycledEquipment(410)email:***************************1981SPECIFICATIONS14Voltage Display Range: 0.00 - 6.00 KV Full Scale0.00 - 5.00 KV Full Scale for 7520DT onlyResolution: 10 volt/stepAccuracy: (2 of reading 2 counts)Current Display Auto RangeAC Range 1: 0.000mA - 3.500mAResolution: 0.001mA/stepRange 2: 3.00 - 40.00 mA for 7550DT and 7564SA,3.00 - 20.00 mA for 75/20/30/40DTResolution: 0.01 mA/stepDC Range 1: 0.0 A - 350.0 AResolution: 0.1A/stepRange 2: 300 A - 3500 AResolution: 1A/stepRange 3: 3000 A - 9990 AResolution: 10A/stepAccuracy: All Ranges (2 of reading 2 counts)DC Output Ripple 4**********************,ResistiveLoad Discharge Time 200 msMaximum CapacitiveLoad DC Mode1uF < 1KV0.75uF < 2KV0.5uF < 3KV0.08uF < 4KV0.04uF < 5KV0.01uF < 6KVAC Output Wave Form Sine Wave, Crest Factor = 1.3 - 1.5Output Frequency Range: 60 or 50 Hz, User SelectionAccuracy: 1%Output Regulation (1 of setting 5 volts) from no load to full load Dwell Timer Range: 0, 0.3 - 999.9 sec (0 = Constant)Resolution: 0.1 sec incrementsAccuracy: (0.1% + 0.05 sec)Ramp Timer Range: AC 0.1 - 999.9 secDC 0.4 - 999.9 secResolution: 0.1 sec incrementsAccuracy: (0.1% + 0.05 sec)RecycledEquipment(410)email:***************************SPECIFICATIONS15Ground Continuity For 75/20/30/40/50DT Current : DC 0.1 A 0.01A, fixedMax. ground resistance : 1 0.1, fixed Ground Fault Interrupt GFI Trip Current: HV Shut Down Speed: 450 A max (AC or DC)< 1msINSULATION RESISTANCE TEST MODE Model 75/30/40/50DT, 7564SAOutput VoltageRange:100 - 1000 Volts DC Resolution: 1 volt/step Accuracy:(2 of reading 2 volts) Short Circuit Current Maximum: 12mA peak Voltage DisplayRange: 0 - 1000 VResolution: 1 volt/stepAccuracy:(2 of reading 2 counts) Resistance DisplayRange: 1 - 9999 M (4 Digit, Auto Ranging)Resolution:500VDC 1000VDC M M M 0.001 1.000 - 5.388 1.000 - 9.999 0.01 1.40 - 53.88 2.80 - 99.99 0.1 14.0 - 538.8 28.0 - 999.9 1104 - 9999280 - 9999Accuracy:(2 of reading 2 counts) at test voltage 500 - 1000V and 1 - 1000 M(8 of reading 2 counts) at test voltage 500 - 1000V and 1000 - 9999 M(8 of reading 2 counts) at test voltage 100 - 500V and 0 - 1000 MCharge-LO Range: 0.000 - 3.500A or Auto Set HI-Limit Range: 0 - 9999 M (0 = Off) LO-Limit Range: 1 - 9999 MDelay TimerRange: 0, 0.5 - 999.9 sec (0 = Constant) Resolution: 0.1 sec/stepAccuracy:(0.1% + 0.05 sec)Ground Fault InterruptGFI Trip Current:HV Shut Down Speed:450 A max (AC or DC) < 1msRecycledEquipment(410)email:***************************SPECIFICATIONS16GROUND BOND TEST MODE Model 7564SA onlyOutput Voltage Range: 3.00 - 8.00 Volts AC (Open Circuit Limit) Resolution: 0.01 volt/stepAccuracy: (2 % of Setting + 0.03V ) O.C. Condition Output Frequency Range: 60 or 50 Hz, User Selection Accuracy: 1%Output CurrentRange: 3.00 - 30.00 Amps AC Resolution: 0.01 Amp/stepAccuracy :(2 % of Setting + 0.02 A) Current DisplayRange: 0.00 - 30.00 Amps Resolution: 0.01 Amp/stepAccuracy:(3 % of Reading + 0.03 A) Resistance DisplayRange: 0 - 600 m Resolution: 1 m /stepAccuracy:(2 % of Reading + 2 m ) HI-LimitRange: 0 - 600 m for 3 - 10 A 0 - 150 m for 3 - 30 A Resolution: 1 m /stepAccuracy:(2 % of Setting + 2 m ) LO-LimitRange: 0 - 600 m for 3 - 10 A 0 - 150 m for 3 - 30 A Resolution: 1 m /stepAccuracy:(2 % of Setting + 2 m ) Dwell TimerRange: 0, 0.5 - 999.9 sec (0 = Constant) Resolution: 0.1 sec/step Accuracy:(0.1% + 0.05 sec)Milliohm OffsetMax. Offset Capability: 200 mResolution: 1 m / stepAccuracy:(2 % of Setting + 2 m )RecycledEquipment(410)email:***************************SPECIFICATIONS17GENERAL SPECIFICATIONSPLC Remote Control Input - Test, Reset, Recall memory 1, 2 and 3Output - Pass, Fail, Test-in-ProcessMemory Allows storage of up to 50 groups different test programsand 8 step/each memory. Step is not available on 7520DT SecurityProgrammable password lockout capability to avoid unauthorized access to test set-up program. LCD Contrast Setting 9 ranges set by the numeric keys on the front panel. Buzzer Volume Setting 10 ranges set by the numeric key on the front panel.Calibration Software and adjustments are made through front panel. Mechanical Bench or rack mount with tilt up front feet. Dimension7540DT, 7550DT and 7564SA:(W x H x D) 17 x 5.8 x 20.3 in. (432 x 147 x 515 mm) 7520DT and 7530DT:(W x H x D) 17 x 5.8 x 12 in. (432 x 147 x 305 mm)Weight7564SA without scanner 52.5 lbs (24 Kgs) 7564SA with built-in scanner 57.0 lbs (26 Kgs) 7550DT without scanner 50.5 lbs (23 Kgs) 7550DT with built-in scanner 55.0 lbs(25 Kgs) 7540DT with 4 port scanner 39.6 lbs (18 Kgs) 7540DT with 8 port scanner41.8 lbs(19 Kgs) 7530DT scanner not available 24.8 lbs (11.27 Kgs) 7520DT scanner not available 24.8 lbs(11.27 Kgs)Scanner Port Two Port Maximum including the built-in scanner. Not available on 7520DT, 7530DT and 7540DT.Scanner Built-in OptionHigh Voltage x 4 Ports (7540DT only)High Voltage x 8 Ports (75/40/50DT and 7564SA) Ground Bond x 8 Ports (7564SA only)RecycledEquipment(410)email:***************************。

飞瑞公司产品说明书:FESX型号电子管动量阀

飞瑞公司产品说明书:FESX型号电子管动量阀

1/18Proportional cartridge throttle valve, with inductive position transducer, pilot operatedType FESXNominal size 16, 25, 32, 40, 50Unit series 1XMaximum working pressure A, B, X 315 bar, Y 100 bar Nominal flow rate Q nom 980 l/minRE 29215/09.05Overview of ContentsContents PageFeatures 1Ordering data 2Preferred types2Symbol 2Function, sectional diagram 3T echnical data4 and 5External trigger electronics 6 to 8Characteristic curves 9 and 10Unit dimensions 11 to 15Installation dimensions16 and 17Features– P ilot operated throttle valves with inductive position transducer – D esign: cartridge type DIN 24342, ISO/DIS 7368Control oil external X and Y– A djustable via the position-controlled main stage by means of the position transducer and the external valve electronics – H ysteresis < 0.2 %, positioning accuracy > 0.5 %, see T echnical Data– P lug-in connector to DIN 43650-AM2 for the solenoidand plug-in connector for the position transducer, included in scope of delivery– D ata for the external trigger electronics • U B = 24 V nom DC• Adjustment of valve curve Np and gain, with and without ramp generator• Europe card format, setpoint 0...+10 V (order separately)o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mOrdering dataProportional throttle valve with inductive position transducer (pilot operated)Nominal size= 16Mounting hole configuration = 25DIN 24342, ISO/DIS 7368 = 32 = 40= 50Connection type = C(cartridge)Direction of flow A Ǟ B= A(customer may implement B Ǟ A) Unit series 10 to 19= 1X(10 to 19: installation and connection dimensions unchanged)Further informationin plain textM =NBR seals, suitablefor mineral oils(HL, HLP) to DIN 51524 Z4 =Electrical connection Unit plug to DIN 43650-AM2Plug-in connector includedin scope of deliveryL = Flow characteristicLinear 125 = Nominal flow rate210 = Q nom in l/min 320 = ∆p = 5 bar500 = 980 =FESXC A 1X L Z4M *Preferred typesTypeMaterial Number FESX16CA–1X/125LZ4M 0 811 402 452FESX25CA–1X/210LZ4M 0 811 402 515FESX32CA–1X/320LZ4M 0 811 402 614FESX40CA–1X/500LZ4M 0 811 402 620FESX50CA–1X/980LZ4M0 811 402 633SymbolFor external trigger electronicso u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mFunction, sectional diagramTesting and service equipmentT est box type VT-PE-TB2, see RE 30064Europe card Plug-in connectors4P2P+PEo u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mTechnical data1) T he purity classes stated for the components must be complied with in hydraulic systems. Effective filtration prevents problemsand also extends the service life of components.For a selection of filters, see catalog sheets RE 50070, RE 50076 and RE 50081.o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mStatic/Dynamic 1)NG16NG25NG32NG40NG50Spool stroke/characteristic curve + mm 4571012.5Overlap on shutdown– mm 33333Control oil volume of main stage cm 3100 %1.022.66 6.3612.5724.54Required control oil 0...100 %, l/min x = 100 bar 35799Hysteresis%< 0.2< 0.2< 0.2< 0.2< 0.2Positioning accuracy %< 0.5< 0.5< 0.5< 0.5< 0.5Manufacturing tolerance See flow curves, adjustable via external trigger electronicsResponse time (x = 100 bar) ms Signal change 0...100 % “open”< 70< 70< 90< 90< 110Signal change 100... 0 % “close”< 70< 70< 90< 130< 300Signal change 0... 10 % “open”< 50< 50< 70< 70< 80Signal change 10... 0 % “close”< 40< 40< 50< 70< 100Switch-off behavior, enable “OFF”After electrical shutdown (pilot valve opens “X” to the main stage),main stage moves to closed end position Thermal drift< 1 % at ∆T = 40 °CElectricalCyclic duration factor %100Degree of protection IP 65 to DIN 40050 and IEC 14434/5Solenoid connectionUnit plug DIN 43650/ISO 4400, M16x 1.5 (2P+PE)Position transducer connection Special plug (4P/Pg7)Max. solenoid current I max 2.7 A Coil resistance R 20Ω 2.5Max. power consumption at 100 % VA load and operating temperature 40Position transducer DC/DC technologySupply: +15 V/35 mA Supply: –15 V/25 mASignal: 0...±10 V (R L Ն10 k Ω)1) A ll characteristic values ascertained using amplifier 0 811 405 076 (without ramp).Technical datao u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mValve with external trigger electronics (europe card without ramp, RE 30055)Circuit diagram/pin assignmento u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mValve with external trigger electronics (europe card without ramp, RE 30053)Circuit diagram/pin assignmentS e e f u n c t i o n a l d i a g r a m o f r a m p c o n t r o l o n p a g e 8o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mValve with external trigger electronics (europe card with ramp, RE 30053)Functional diagram of ramp controlo u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mCharacteristic curves (measured with HLP 46,oil = 40 °C ±5 °C)∆p = 5 bar υ = 36 mm 2/sNG16NG25NG32Enable OFFEnable OFFEnable OFFo u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mCharacteristic curves (measured with HLP 46,oil = 40 °C ±5 °C)∆p = 5 bar υ = 36 mm 2/sNG40NG50Enable OFFEnable OFF* Amplifiero u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mUnit dimensions NG16 (nominal dimensions in mm)See installation dimensions on page 16o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mUnit dimensions NG25 (nominal dimensions in mm)See installation dimensions on page 16o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mUnit dimensions NG32 (nominal dimensions in mm)See installation dimensions on page 16o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mUnit dimensions NG40 (nominal dimensions in mm)See installation dimensions on page 17o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mUnit dimensions NG50 (nominal dimensions in mm)See installation dimensions on page 17o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mInstallation dimensions DIN 24342, ISO/DIS 7368 (nominal dimensions in mm)NG16NG25NG32o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mInstallation dimensions DIN 24342, ISO/DIS 7368 (nominal dimensions in mm)NG40NG50o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mBosch Rexroth AG HydraulicsZum Eisengießer 197816 Lohr am Main, Germany T elefon +49 (0) 93 52 / 18-0T elefax +49 (0) 93 52 / 18-23 58*****************************www.boschrexroth.de© This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent.The data specified above only serve to describe the product. No state-ments concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgement and verification. It must be remembered that our products are subject to a natural process of wear and aging.Noteso u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mBosch Rexroth AG HydraulicsZum Eisengießer 197816 Lohr am Main, Germany T elefon +49 (0) 93 52 / 18-0T elefax +49 (0) 93 52 / 18-23 58*****************************www.boschrexroth.de© This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent.The data specified above only serve to describe the product. No state-ments concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgement and verification. It must be remembered that our products are subject to a natural process of wear and aging.Noteso u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mBosch Rexroth AG HydraulicsZum Eisengießer 197816 Lohr am Main, Germany T elefon +49 (0) 93 52 / 18-0T elefax +49 (0) 93 52 / 18-23 58*****************************www.boschrexroth.de© This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent.The data specified above only serve to describe the product. No state-ments concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgement and verification. It must be remembered that our products are subject to a natural process of wear and aging.Noteso u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o m。

光纤传感器产品说明书

光纤传感器产品说明书

'DWD $FTXLVLWLRQ
Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485, Ehernet and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers
Emissivity: 0.05 to 0.99, adjustable in 0.01 steps
with Spot Sizes Down
(±3°F), whichever is greater
Ambient Temperature:
to 0.004" Available
Spectral Response:
Comes with probe assembly, fiber optic cable, mounting bracket, and operator’s manual. Ordering Example: OS1553-L1-R1, fiber optic sensor with 816 to 1370°C (1500 to 2500°F) range, 0.02" spot size at 6" target distance, and PSS-D15B power supply, $2475 + 114 = $2589.
OS1553 SENSOR
FLEXIBLE FIBER CABLE
L1 PROBE

Narda-STS 5G FR2 天线数据手册说明书

Narda-STS 5G FR2 天线数据手册说明书

Datasheet 5G FR2 AntennasMeasurement of 5G NR FR2 Electromagnetic FieldsDownconverter-Antennas for omnidirectional and directional measurement of fields and their sources in the frequency range from 24.25 GHz to 29.5 GHzWith the downconverter antennas, the user gets the pos-sibility to extend the frequency range of the SRM-3006 to frequencies from 24.25 GHz to 29.5 GHz. One of the main applications is to demonstrate compliance with the EMF limits in frequency range FR2 of the 5G NR mo-bile radio service. Of course all other applications in this frequency range can also be measured. The two anten-nas differ in their reception characteristics: The Model 3591/01 features a directional characteristic, while the Model 3591/02 offers an omnidirectional characteristic.›Extends SRM-3006 to cover 24.25 GHz to 29.5 GHz.›Calibrated antennas for reliable measurements ›Measurements are displayed in field strength or in percent of limit values, e.g. ICNIRP , FCC...›Omnidirectional antenna design for environmental measurements›Directional antenna design for weak signals ›Easy to setup ›Simple operation›Fast and reliable measurement resultsTwo different antenna models are available. A directional anten -na with high sensitivity and an omnidirectional antenna. Both antennas include a downconverter that converts the millimeter wave between 24.25 GHz to 29.5 GHz into the SRM-3006’s receive band. This means that the RF cable between antenna and basic unit only transmits frequencies up to a maximum of 6 GHz, which greatly reduces the cable loss compared with a 20 GHz cable. In addition, the downconverter in the antenna avoids the need to modify the base unit, so the antenna can be used on all SRM-3006 devices without hardware modifications. Only a firmware update is required, which can be done by the user.The antennas have their own batteries, independent from the basic unit. So the runtime of the SRM is not affected by the op -eration of the downconverter antenna. The battery integrated in the antenna can be charged via an USB-C socket. Connected to a USB power bank, long-term measurements can also be performed.Narda recommends to operate the antennas only via an exten-sion cable with the SRM.Measurement of weak signals (e.g. indoors):For measurements inside buildings, the field strengths are often very low. For example, a modern, coated glass window can at-tenuate a signal at 24 GHz by about 30 dB. To be able to detect such a field strength, a high gain antenna is needed. However, such antennas have a high directivity due to their principle. The antenna model 3591/01 has such a characteristic.In addition, the directional characteristic can be used to detect the field strength of geographically separated base stations..Outdoor environmental measurements:For EMF measurements, national as well as international standards recommend an isotropic measurement. Such anten-nas are not available for the FR2 frequency range. The antenna 3591/02 offers an omnidirectional reception characteristic that roughly corresponds to that of a donut. Ideal reception results are therefore obtained from an X-Y spatial plane. To cover all three spatial axes for isotropic measurements, the antenna must be connected to the basic unit via an RF cable and moved accordingly during the measurement.Available Antenna ModelsFig. 1.3591/01 Directional Antenna (Horn antenna)Fig. 2. 3591/02 OmnidirectionalConditionsUnless otherwise noted, specifications apply after 30 minutes warm-up time within the specified environmental conditions. The product is within the recommended calibration cycle.Specifications with limitsThese describe product performance for the given parameter cov-ered by warranty. Specifications with limits (shown as <, ≤, >, ≥, ±, max., min.) apply under the given conditions for the product and are tested during production, considering measurement uncertainty. Specifications without limitsThese describe product performance for the given parameter cov-ered by warranty. Specifications without limits represent values with negligible deviations, which are ensured by design (e.g. dimensions or resolution of a setting parameter).Typical values (typ.)These characterize product performance for the given parameter that is not covered by warranty. When stated as a range or as a limit (shown as <, ≤, >, ≥, ±, max., min.), they represent the performance met by approximately 80% of the instruments. Otherwise, they rep-resent the mean value. The measurement uncertainty is not taken into account.Nominal values (nom.)These characterize expected product performance for the given pa-rameter that is not covered by warranty. Nominal values are verified during product development but are not tested during production. UncertaintiesThese characterize the dispersion of the values attributed to the measurands with an estimated confidence level of approximately 95%. Uncertainty is stated as the standard uncertainty multiplied by the coverage factor k=2 based on the normal distribution. The evaluation has been carried out in accordance with the rules of the “Guide to the Expression of Uncertainty in Measurement” (GUM).Specifications3591/01 LNB Antenna, 24.25 GHz to 29.5 GHz, directional3591/02 LNB Antenna, 24.25 GHz to 29.5 GHz, omnidirectionalGeneralOrdering informationYour local Narda representative will inform you of all possible options as well as the current ordering information and will be pleased to provide you with advice.Narda Safety Test Solutions GmbH Sandwiesenstrasse 772793 Pfullingen, GermanyPhone +49 7121 97 32 0****************** Narda Safety Test SolutionsNorth America Representative Office435 Moreland RoadHauppauge, NY11788, USAPhone +1 631 231 1700******************Narda Safety Test Solutions S.r.l.Via Rimini, 2220142 Milano, ItalyPhone +39 0258188 1****************************Narda Safety Test Solutions GmbHBeijing Representative OfficeXiyuan Hotel, No. 1 Sanlihe Road,Haidian100044 Beijing, ChinaPhone +86 10 6830 5870********************® Names and Logo are registered trademarks of Narda Safety Test Solutions GmbH – Trade names are trademarks of the owners.。

爱森摩尔Z5型号超压保护器说明说明书

爱森摩尔Z5型号超压保护器说明说明书

Eaton 210075Eaton Moeller® series Z5 Overload relay, Ir= 200 - 250 A, 1 N/O, 1 N/C, For use with: DILM250, DILM300AGeneral specificationsEaton Moeller® series Z5 Thermal overload relay2100754015082100759Z5-250/FF250146 mm 167 mm 128 mm 1.727 kgIEC/EN 60947UL Category Control No.: NKCR VDE 0660 CECSA Class No.: 3211-03 ULCSA-C22.2 No. 60947-4-1-14 CSA File No.: 012528 UL 60947-4-1 UL File No.: E29184 IEC/EN 60947-4-1 CSAProduct NameCatalog Number EANModel Code Product Length/Depth Product Height Product Width Product Weight CertificationsReset pushbutton manual/autoTrip-free releaseTest/off buttonPhase-failure sensitivity (according to IEC/EN 60947, VDE 0660 Part 102)-25 °C60 °C25 °C40 °CCLASS 10 ADamp heat, constant, to IEC 60068-2-78Damp heat, cyclic, to IEC 60068-2-30IP00Separate mountingDirect mountingDirect attachment/single positioning200 A250 AIII3Overload relay Z5With terminal cover, Protection against direct contact when actuated from front (EN 50274)4000 V (auxiliary and control circuits)8000 V ACFeatures Ambient operating temperature - minAmbient operating temperature - maxAmbient operating temperature (enclosed) - minAmbient operating temperature (enclosed) - maxClassClimatic proofingDegree of protectionMounting methodOverload release current setting - minOverload release current setting - maxOvervoltage categoryPollution degreeProduct categoryProtectionRated impulse withstand voltage (Uimp)Shock resistance10 g, Mechanical, Sinusoidal, Shock duration 10 ms Branch circuits, (UL/CSA)≤ 0.25 %/K, residual error for T > 40° Continuous 25 mm width, Main connection185 mm²2 x (0.75 - 2.5) mm², Control circuit cables1 x (0.75 - 2.5) mm², Control circuit cables1 x (0.75 - 4) mm², Control circuit cables2 x (0.75 - 4) mm², Control circuit cables2/0 - 500 MCM, Main cables2 x (18 - 14), Control circuit cables185 mm²16 mm (Hexagon head spanner SW)8 mmM10 x 35, Terminal screw, Main connectionsM3.5, Terminal screw, Control circuit cables1 x 6 mm, Terminal screw, Control circuit cables, Standard screwdriver2, Terminal screw, Control circuit cables, Pozidriv screwdriver18 Nm, Main cable connection screw/bolt1.2 Nm, Screw terminals, Control circuit cables6 A 1.5 A 1200 A Class L, max. Fuse, SCCR (UL/CSA) 18 kA, SCCR (UL/CSA)1200 A, max. CB, SCCR (UL/CSA)500 A gG/gL, Fuse, Type “1” coordinationSuitable forTemperature compensationTerminal capacity (busbar)Terminal capacity (flexible with cable lug)Terminal capacity (flexible with ferrule)Terminal capacity (solid)Terminal capacity (solid/stranded AWG)Terminal capacity (stranded with cable lug)Width across flatsStripping length (control circuit cable)Screw sizeScrewdriver sizeTightening torqueConventional thermal current ith of auxiliary contacts (1-pole,open)Rated operational current (Ie) at AC-15, 120 VShort-circuit current rating (basic rating)Short-circuit protection rating1.5 A0.9 A0.4 A0.2 A0.9 A0.75 A1000 V440 V, Between auxiliary contacts and main contacts, According to EN 61140240 V AC, Between auxiliary contacts, According to EN 61140 500 V AC, Between main circuits, According to EN 61140R300, DC operated (UL/CSA)B300 at opposite polarity, AC operated (UL/CSA)B600 at opposite polarity, AC operated (UL/CSA)600 VAC600 VAC 500 A gG/gL, Fuse, Type “2” coordinationMax. 6 A gG/gL, fuse, Without welding, Auxiliary and control circuits111143.5 W0 W14.5 W250 A0 WMeets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V Rated operational current (Ie) at DC-13, 110 VRated operational current (Ie) at DC-13, 220 V, 230 V Rated operational current (Ie) at DC-13, 24 VRated operational current (Ie) at DC-13, 60 VRated operational voltage (Ue) - maxSafe isolationSwitching capacity (auxiliary contacts, pilot duty) Voltage rating - maxVoltage rating - max Number of auxiliary contacts (change-over contacts)Number of auxiliary contacts (normally closed contacts) Number of auxiliary contacts (normally open contacts) Number of contacts (normally closed contacts)Number of contacts (normally open contacts)Equipment heat dissipation, current-dependent PvidHeat dissipation capacity PdissHeat dissipation per pole, current-dependent PvidRated operational current for specified heat dissipation (In) Static heat dissipation, non-current-dependent Pvs10.2.2 Corrosion resistance10.2.3.1 Verification of thermal stability of enclosures10.2.3.2 Verification of resistance of insulating materials to normal heat10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.Is the panel builder's responsibility. The specifications for the switchgear must be observed.Product Range Catalog Switching and protecting motorseaton-tripping-devices-z5-overload-relay-characteristic-curve-003.eps eaton-tripping-z5-overload-relay-characteristic-curve.epsDA-DC-00004856.pdfDA-DC-00004846.pdfeaton-tripping-devices-overload-relay-z5-overload-relay-dimensions-002.epseaton-tripping-devices-overload-relay-z5-overload-relay-3d-drawing.epsDA-CE-ETN.Z5-250_FF250IL03407006ZIL026005ZUIL03407081ZDA-MN-h1476dgbDA-CS-z5_ff250DA-CD-z5_ff250eaton-general-release-zeb-overload-relay-wiring-diagram.epseaton-tripping-devices-overload-relay-zeb-overload-relay-wiring-diagram.eps10.2.4 Resistance to ultra-violet (UV) radiation10.2.5 Lifting10.2.6 Mechanical impact10.2.7 Inscriptions10.3 Degree of protection of assemblies10.4 Clearances and creepage distances10.5 Protection against electric shock10.6 Incorporation of switching devices and components 10.7 Internal electrical circuits and connections10.8 Connections for external conductors10.9.2 Power-frequency electric strength10.9.3 Impulse withstand voltage10.9.4 Testing of enclosures made of insulating material 10.10 Temperature rise10.11 Short-circuit rating10.12 Electromagnetic compatibility CatalogsCharacteristic curve Declarations of conformity DrawingseCAD modelInstallation instructionsManuals and user guides mCAD modelWiring diagramsEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaIs the panel builder's responsibility. The specifications for the switchgear must be observed.The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.10.13 Mechanical function。

Belden FiberExpress 12核 OM3 OFNR 纤维光缆说明书

Belden FiberExpress 12核 OM3 OFNR 纤维光缆说明书

Page 1 of 3
04-18-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
B9C042T Fiber - Indoor/Outdoor Distribution Cable - Riser
24* LSZH In/ Outdoor B9B107 B9A107 B9C107
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
B9C042T Fiber - Indoor/Outdoor Distribution Cable - Riser
For more Information please call
Strength Member Material:
Black Aramidcteristics (Overall)
Storage Temperature Range: Installation Temperature Range: Operating Temperature Range: Bulk Cable Weight: Min. Bend Radius/Minor Axis: Min. Bend Radius for Long Term Application: Max. Load for Installation: Max. Load for Long Term Application:
B9B602 B9A602 B9C602 B9E602 .
24
Indoor / Outdoor B9B602T B9A602T B9C602T B9E602T .

NACV330M250V10x10.8TR13F中文资料

NACV330M250V10x10.8TR13F中文资料

16®NIC COMPONENTS CORP. www www www www .SMTmagnetics.comSurface Mount Aluminum Electrolytic CapacitorsNACV SeriesFEATURES•CYLINDRICAL V-CHIP CONSTRUCTION FOR SURFACE MOUNT •HIGH VOLT AGE (160VDC AND 400VDC)•8 x10.8mm ~ 16 x17mm CASE SIZES •LONG LIFE (2000 HOURS A T +105O C)•DESIGNED FOR REFLOW SOLDERING CHARACTERISTICSDIMENSIONS (mm)CE MOUNT RoHSCompliantincludes all homogeneous materials *See Part Number System for DetailsNACV 100 M 200V 10x10.8 TR 13 FRoHS Compliant97% Sn (min.), 3% Bi (max.) 330mm (13”) Reel Tape & Reel Size in mm Working VoltageT olerance Code M=20%, K=10% Capacitance Code in µF , fi rst 2 digits are signifi cant Third digit is no. of zeros, “R” indicates decimal for values under 10mF SeriesPART NUMBER SYSTEM0.3mm max.D φL+ -IIWPABSTANDARD PRODUCTS AND CASE SIZES (mm)MAXIMUM RIPPLE CURRENT(mA rms AT 120Hz AND 105°C)MAXIMUM ESR (Ω AT 120Hz AND 20°C)Rated Voltage Range 160200250400Rated Capacitance Range 10 ~ 8210 ~ 68 3.3 ~ 47 2.2 ~ 22Operating Temperature Range-40 ~ +105°C Capacitance Tolerance ±20% (M)Max. Leakage Current After 2 Minutes0.03CV + 15µA 0.02CV + 25µAMax. Tan δ @ 120Hz0.200.200.200.25Low Temperature Stability(Impedance Ratio @ 120Hz)Z-25°C/Z+20°C 3336Z-40°C/Z+20°C66610High Temperature Load Life at 105°C2,000 hrs φD > 10mm 1,000 hrs φD = 8mm Capacitance Change Within ±25% of initial measured value Tan δLess than 200% of specifi ed value Leakage CurrentLess than the specifi ed valueCap. (µF)Working Voltage 1602002504002.2---253.3--31364.7--37386.8--444710576464572211211211211533137137150-47180180180-68215215--82235---Cap. (µF)Working Voltage 1602002504002.2---188.53.3--100.5125.74.7--70.688.26.8--48.861.01033.233.233.241.52215.115.115.118.83310.110.110.1-477.17.17.1-68 4.9 4.9--824.0---Cap. (µF)Code Working Voltage1602002504002.22R2---8x10.83.33R3--8x10.810x10.84.74R7--8x10.810x10.86.86R8--8x10.812.5x14101008x10.810x10.810x10.812.5x142222012.5x1412.5x1412.5x1416x173333012.5x1412.5x1416x17-4747016x1716x1716x17-6868016x1716x17--8282016x17---Case Size D φ±0.5L max.A±0.2B±0.2I±0.2W P±0.28x10.88.010.88.38.3 2.90.7~1.0 3.210x10.810.010.810.310.3 3.2 1.1~1.4 4.612.5x1412.514.012.812.8 4.5 1.1~1.4 4.616x1716.017.016.316.35.01.8~2.17.0PRECAUTIONSPlease review the notes on correct use, safety and precautions found on pages T10 & T11of NIC’s Electrolytic Capacitor catalog . Also found at /precautionsIf in doubt or uncertainty, please review your specifi c application - process details withNIC’s technical support personnel: tpmg@元器件交易网。

RCU 501 远程控制单元产品说明书

RCU 501 远程控制单元产品说明书

RCU501 is a high performance, general purpose, real-time process control computer for use in a wide variety of system applications in both on- and offshore installations. The processor core is an embedded Power PC™ architecture and the module is approved for Ex Zone 2 applications.Application types• Dynamic Positioning Systems• Thruster Control / Steering Systems • Navigation Sensor Integrator• Integrated Process Control Systems • Alarm and monitoring Systems • Safety SystemsFunction• Dual ethernet LAN process networks • Dual RedundancyNet interface for redundant RCU con fi guration• Dual Remote IO process BUS (RBUS) • 4 general purpose Digital Input channels • 4 general purpose Digital Output channels• 32 serial lines for 3rd party interface • 2 PROFIBUS channels for 3rd party interface• 2 CANBUS channels for 3rd party interfaceFeature• Single unit topology: SIL 1 compliant • Dual unit topology: SIL 2 and SIL 3compliant• Triple unit topology • Ex Zone 2 approved• Compliant to the following protocols:1. Modbus (Serial and TCP)2. NMEA 01833. PROFIBUS/PROFIsafe4. CAN/DeviceNet • 3rd party vendor speci fi c protocols are available upon request • Power:1. Redundant power input with power alarm monitoring2. Inrush current and over-voltage protection• Enhanced watchdog with fail-safe function and system status outputBene fi tsThe following built-in functions minimize system downtime:• Extended Built-in Self- Test (BIST) for computer diagnostics and fault identi fi cation during start-up and runtime • Prepared for online remote diagnostics • Prepared for online fi rmware upgrade • Bootable from fi le server or local fl ash memory• Easy installation and replacement 1. DIN Rail mounting2. All connections are pluggable3. 3 digit address switches• Hot swap in redundant applications,dual and triple Hot-Standby redundancy, 1oo2 redundancy• Status LED indication (Normal/Error)• RoHS compliantComputer performance• RCU501 performance is application dependant and governed by process complexity, updating frequency and number of interfaced I/O. Maximum updating frequency is 50 Hz.• Con fi guration guidelines:1. ESD/PSD: max. 800 I/O,F&G: max. 700 I/O both at scan rate: 1 Hz 2. Process/ Automation:max. 2000 I/O,design advice: 1280 I/O both at scan rate: 1 Hz3. Anti-surge: 3 loops, Scan rate: 50 Hz4. Dynamic Positioning: Tripleredundant DP system combined with Position Mooring. (Scan rate is adapted to signal processing and varies from 1 to 10 Hz).312729 Rev. B / September 2010KM article numberRCU501: 603439StandardsRCU501 complies with the following:• IACS E10• IEC 60533• IEC 60945• IEC 61508• IEC 62061Type approvalRCU501 is type approved by:• Det Norske Veritas (DNV)• The American Bureau of Shipping(ABS) • TÜV Rheinland• Wurldtech™; Achilles level 1certi fi edCE markingCE mark compliant, con fi rm to:• 2004/108/EC (EMC directive)• 94/9/EC (Atex directive)Ex certi fi cationEx nA II T4 (Zone 2)Environmental speci fi cationsAmbient temperatures and humidity:• Temp. Operation: -15˚C to 70˚C • Temp. Storage: -25˚C to 70˚C• Humidity Operation: Up to 98% RH • Humidity Storage: Up to 98% RH Protection Standards: IP 20DimensionsHeight: 355 mm Width: 158 mm Depth: 87 mm Weight: 1.35 kgCross point screw lock on DIN Rail T35 7.5/15 according to EN 50022ElectricalInput supply voltage: 24 VDC (+30%, -25%)Nominal current consumption: ≈ 0.8 A Start-up current: Max. 2.7 A Power consumption: Max. 20 W Heat dissipation: Max. 20 W Power connectors:• Screw terminals (slotted) • Cable cross section: 2.5 mm²Processor and memory Processor:• Type: Power PC TM host processorMPC8245• Clock frequency: 400 MHzMemory:• RAM size and speed: 64 MB @ 133MHz• PROM: 16 MB application fl ash-fi leSerial lineChannels: 32 insulated serial lines, distributed on 8 RJ45 connectors Physical layer: RS232, RS422 and RS485 Multidrop via RSER200Bit rate: Max. 115 kb/sGeneral purpose I/O channelsDigital Output (DO):• 4 x opto-isolated outputs• 1 x opto-isolated watchdog (forexternal interface)Digital Input (DI): 4 x opto-isolated inputsI/O connectors: • Cage clamps• Cable cross section: 1 mm²LAN interfaceProcess network & RedundancyNet: 2 x RJ45 Ethernet IEEE 802.3 type 10BASE-T/100BASE-TXRBUS interfaceConnector: 2 x RJ45Bit-rate: 2 Mb/sSignal code: Manchester encoded (Self-clocked)Copper wire topology:• Insulation: 500 V (Optocoupler)• Physical layer: RS485 Multidrop • Cable attenuation: < 6.5 db/100m @10 MHz (CAT 5)• Cable length: Max. 200 m betweenrepeaters. Max. 3 repeatersFibre optical topology (w/ additional fi bre media converter):• Fibre cable: 62.5/125 μm. Multimodus • Connector: ST • Cable length: Max. 1000 m (point to point). 500 m if used in patch-panel topology Field interfaceCAN interface:• 2 x CANopen/DeviceNet @ 5 polecage clamp terminals. 2.5 mm² cable • Bit rate: Max. 1 Mb/s. (DeviceNet notde fi ned above 500 kb/s)PROFIBUS interface:• 2 x opto-isolated 9 Pin femaleD-Sub connectors • Bit rate: Max. 12 Mb/sLife cycle predictionPredicted failure rate @ GB 25˚C (60% con fi dent, based on chip suppliers data): 24.2 YearsPredicted failure rate @ NS 35˚C(Environmental de-rating based on RomeLaboratory toolkit): 6.5 Years* KM reserves the right to make changes to the material or product described, at any time without notice.。

阿西康加力N型信号传递器说明书

阿西康加力N型信号传递器说明书

4-1393806-0Axicom Cradle Relay N, Signal Relays, 250VAC Contact Voltage Rating, 250VDCContact Voltage Rating, 747mW Signal Relay Coil Power Rating (DC)10/05/2020 01:10PM | Page 1 For support call+1 800 522 6752Relays, Contactors & Switches>Relays>Signal Relays>Signal Relays: 5 amp, Monostable DCSignal Relay Terminal Type:Plug-In, SolderSignal Relay Mounting Type:Printed Circuit BoardSignal Relay Coil Power Rating (DC):747 mWContact Voltage Rating:250 VDCAll Signal Relays: 5 amp, Monostable DC (138)FeaturesProduct Type FeaturesRelay Type Cradle N Relay V23154/V23162Relay Style Cradle N RelayProduct Type RelayElectrical CharacteristicsCoil Power Rating Class600 – 800 mWActuating System AC/DCInput Voltage250 VDCInsulation Initial Dielectric Between Open Contacts1000 VrmsContact Limiting Short-Time Current 5 AInsulation Initial Dielectric Between Contacts and Coil1500 VrmsInsulation Initial Dielectric Between Coil/Contact Class1000 V – 1500 VAInsulation Initial Dielectric Between Adjacent Contacts1000 VrmsPower Consumption800 mWInsulation Initial Resistance1000000 MΩContact Limiting Making Current 5 ACoil Resistance20900 ΩContact Limiting Continuous Current 5 ACoil Type MonostableContact Limiting Breaking Current 5 A4-1393806-0 ACTIVEAxicomTE Internal #:4-1393806-0Axicom Cradle Relay N, Signal Relays, 250VAC Contact VoltageRating, 250VDC Contact Voltage Rating, 747mW Signal Relay CoilPower Rating (DC)View on >Axicom Cradle Relay N|Coil Type MonostableContact Limiting Breaking Current 5 AContact Voltage Rating250 VDCSignal Relay Coil Power Rating (DC)747 mWSignal Relay Coil Voltage Rating125 VDCSignal Relay Contact Switching Voltage (Max)250 VDCSignal Relay Coil Magnetic System Monostable, DCBody FeaturesWeight20 g[.706 oz]Contact FeaturesContact Plating Material GoldContact Current Class 2 – 5 AContact Special Features Single ContactSignal Relay Terminal Type Plug-In, SolderSignal Relay Contact Current Rating 2 ASignal Relay Contact Arrangement 2 Form C (CO)Contact Material Gold FContact Number of Poles2Termination FeaturesTermination Type Plug-In/SolderMechanical AttachmentSignal Relay Mounting Type Printed Circuit BoardDimensionsWidth Class (Mechanical)12 – 16 mmWidth13 mm[.512 in]Height30 mm[1.181 in]Length Class (Mechanical)20 – 25 mmHeight Class (Mechanical)25 – 30 mmLength24 mm[.945 in]Dimensions (L x W x H) (Approximate)19 x 24 x 30 mm[.748 x .945 x 1.181 in]Usage ConditionsEnvironmental Ambient Temperature (Max)70 °C[158 °F]Environmental Ambient Temperature Class50 – 70°CEnvironmental Category of Protection RTI10/05/2020 01:10PM | Page 2 For support call+1 800 522 6752Environmental Category of Protection RTIOperating Temperature Range-40 – 70 °COperation/ApplicationPerformance Type StandardPackaging FeaturesPackaging Method Box & CartonOtherAdditional Features Earth Terminal, Silver-Plated TerminalsProduct ComplianceFor compliance documentation, visit the product page on >EU RoHS Directive 2011/65/EU CompliantEU ELV Directive 2000/53/EC CompliantChina RoHS 2 Directive MIIT Order No 32, 2016No Restricted Materials Above ThresholdEU REACH Regulation (EC) No. 1907/2006Current ECHA Candidate List: JUN 2020(209)Candidate List Declared Against: JAN 2019(197)Does not contain REACH SVHCHalogen Content Low Halogen - Br, Cl, F, I < 900 ppm perhomogenous material. Also BFR/CFR/PVCFreeSolder Process Capability Wave solder capable to 265°CProduct Compliance DisclaimerThis information is provided based on reasonable inquiry of our suppliers and represents our current actual knowledgebased on the information they provided. This information is subject to change. The part numbers that TE has identified asEU RoHS compliant have a maximum concentration of 0.1% by weight in homogenous materials for lead, hexavalentchromium, mercury, PBB, PBDE, DBP, BBP, DEHP, DIBP, and 0.01% for cadmium, or qualify for an exemption to theselimits as defined in the Annexes of Directive 2011/65/EU (RoHS2). Finished electrical and electronic equipment productswill be CE marked as required by Directive 2011/65/EU. Components may not be CE marked. Additionally, the partnumbers that TE has identified as EU ELV compliant have a maximum concentration of 0.1% by weight in homogenousmaterials for lead, hexavalent chromium, and mercury, and 0.01% for cadmium, or qualify for an exemption to these limitsas defined in the Annexes of Directive 2000/53/EC (ELV). Regarding the REACH Regulation, the information TE provideson SVHC in articles for this part number is based on the latest European Chemicals Agency (ECHA) ‘Guidance onrequirements for substances in articles’ posted at this URL: https://echa.europa.eu/guidance-documents/guidance-on-reachCompatible Parts10/05/2020 01:10PM | Page 3 For support call+1 800 522 675210/05/2020 01:10PM | Page 4For support call+1 800 522 6752TE Model / Part #169424-1HD20 R.F.HANDTOOLTE Model / Part #6-1393813-6CRADLE S RELAY V23054TE Model / Part #1393760-1CRADLE RELAY ACCESSORYTE Model / Part #827468-1LOW & MEDIUM POWER HEADERTE Model / Part #7-1393091-2MT321060TE Model / Part #1-1393092-6MT3330C4TE Model / Part #796500-1CPC POSTED RCPT,13-7,R/ATE Model / Part #1454509-2TNB HAND TOOL:3800088-02TE Model / Part #1-796406-1CPC SERIES 1 POSTEDSignal Relays(209)TE Model / Part #1393827-1V23154Z1021TE Model / Part #CAT-AX41-C8422CRADLE RELAY ACCESSORYAlso in the Series Axicom Cradle Relay NCustomers Also BoughtDocumentsDocumentsCAD Files3D PDF3DCustomer View ModelENG_CVM_CVM_4-1393806-0_A.2d_dxf.zipEnglishCustomer View ModelENG_CVM_CVM_4-1393806-0_A.3d_igs.zipEnglishCustomer View ModelENG_CVM_CVM_4-1393806-0_A.3d_stp.zipEnglishTerms and ConditionsBy downloading the CAD file I accept and agree to the of use.Datasheets & Catalog PagesIndustrial Relays Quick Reference GuideEnglishProduct SpecificationsProduct SpecificationEnglishDefinitions RelaysEnglish10/05/2020 01:10PM | Page 5 For support call+1 800 522 6752。

奥克斯科普OX5042英文快速引导说明书

奥克斯科普OX5042英文快速引导说明书

OscilloscopeModel OX 5042Quick Start GuideENGLISH(1) U.S. Wall Plug 18W, 100-240V, 50/60Hz Cat. #5000.51USB DRIVE CONTENTS: The SX-METRO software and the Handscope’s complete userAlso Included:(1) Test Report(1) Battery Information Sheet(6) 1.2V NiMH rechargeable batteries 2700mA/h Handscope OscilloscopeModel OX5042(2) Probe 10:1 600V/BNC-MCat. #5000.50PRODUCT PACKAGING 2150.21Shipping Contents:(1) Black Tool BagCat. #2133.72(1) USB Drive(software and manual)(1) Set of two,color-coded leads and clipsCat. #2140.63(1) BNC AdapterCat. #2118.46(1) USB Cable + DriverCat. #2135.41(1) Set of two, color-coded probes Cat. #2152.23(1) U.S. Wall Plug 18W, 100-240V , 50/60Hz Cat. #5000.51USB DRIVE CONTENTS: The SX-METRO software and the Handscope’s complete user Also Included:(1) Test Report(1) Battery Information Sheet(6) 1.2V NiMH rechargeable batteries 2700mA/h(1) Current Probe MN251TCat. #2132.59(1) USB Drive (software and manual)(1) Set of two,color-coded leads and clipsCat. #2140.63(1) BNC AdapterCat. #2118.46(1) Probe 10:1 600V/BNC-M Cat. #5000.50(1) USB Cable + DriverCat. #2135.41Shipping Contents:(1) Set of two, color-coded probes Cat. #2152.23(1) Current Probe MF3000-24-1-1Cat. #2132.63(1) Carrying CaseCat. #2155.77Handscope OscilloscopeModel OX5042(1) U.S. Wall Plug 18W, 100-240V , 50/60Hz Cat. #5000.51USB DRIVE CONTENTS: The SX-METRO software and the Handscope’s complete user Also Included:(1) Test Report(1) Battery Information Sheet(6) 1.2V NiMH rechargeable batteries 2700mA/h(1) Current Probe MN379TCat. #2153.02(1) USB Drive (software and manual)(1) Set of two,color-coded leads and clipsCat. #2140.63(1) BNC AdapterCat. #2118.46(1) Probe 10:1 600V/BNC-M Cat. #5000.50(1) USB Cable + DriverCat. #2135.41Shipping Contents:(1) Set of two, color-coded probes Cat. #2152.23(1) Current Probe MF3000-24-1-1Cat. #2132.63(1) Carrying CaseCat. #2155.77Handscope OscilloscopeModel OX5042Precautions Before UseThe operator and/or the responsible authority must carefully read and completely understand the precautions before use. If you use this instrument in an unspecified manner, the protection it ensures can be compromised, thus putting you in danger.• This instrument is designed for use:-indoors-in a level 2 pollution environment-at an altitude below 2000 m-at a temperature between 0° C and 40° C-with a relative humidity of less than 80% up to 35° C.• The safety of all systems, including the instrument, is the responsibility of the operator.• It can be used for measurements on 600V CAT III circuits, relative to the ground/ earth.• Before each use, check the condition of the insulation on the cables, boxes, sensors and accessories. Any element on which the insulation is damaged(even partially) must be taken out of service for repair or disposal.• Respect the environmental and storage conditions.• The external power supply must be connected to the instrument and to the network (98 to 264 V AC).• The power supply to the instrument is fitted with an automatically resettable electrical protection after disappearance of the fault.• As a safety measure, only use factory supplied parts and accessories.• It is advised to use individual safety protection whenever the environmental situations in which the instrument is used require it.• When handling the sensors or test probes, do not place your fingers beyond the physical guard.• If the battery housing cover is absent, damaged or incorrectly positioned, the instrument must not be used other than to adjust the sensors.Definition of Measurement Categories (CAT)CAT IV Measurement category IV corresponds to measurements taken at the source of low-voltage installations.Example: power feeders, counters and protection devices.CAT III Measurement category III corresponds to measurements on building installa-tions.Example: distribution panel, circuit-breakers, machines or fixed industrialdevices.CAT II Measurement category II corresponds to measurements taken on circuits directly connected to low-voltage installations.Example: power supply to domestic electrical appliances and portable tools.Symbols UsedCAUTION! Risk of electric shock. The voltage at theparts marked with this symbol may be dangerous.Warning: Risk of danger. Refer to the operating manual to find out the nature ofthe potential hazards and the action necessary to avoid such hazards.Earth/GroundDual insulationThe trash can with a line through it means that in the European Union, the prod-uct must undergo selective disposal for the recycling of electric and electronicmaterial, in compliance with Directive WEEE 2002/96/EC.The CE marking guarantees conformity with European directives and with regu-lations covering EMC.Application or withdrawal not authorized for non-insulated conductors carryingdangerous voltage levelsPower SupplyThe oscilloscope is supplied with one external power supply and set of 6 x 1.2V NiMH rechargeable batteries 2700mA/h.When the supplied wall plug is connected from the instrument to an external power source, battery power is not needed. The batteries are only used when there is no external power supply available.Before the first use, start by fully charging the battery.When the batteries are recharging, the Battery Charge LED on the front panel will turn on steady.The LED will blink in the following situations:• pre-charge of very low batteries• temperature is too low or too high• batteries are damagedWhen the charge is complete, the LED will turn off.If the batteries need to be replaced, they must be replaced with NiMH rechargeable batteries. Battery charge life is guaranteed for same-capacity batteries (in mAh) as those shipped with the oscilloscope.To remove the battery cover, use a coin to turn the slot on the back of the unit counter-clockwise.DescriptionThe Handscope Oscilloscope Model OX5042-CK combines three instruments into one:• 40MHz oscilloscope• Independent 8000-count multimeter with power measurements• Built-in harmonic analyzer out to the 31st harmonic (fundamental between 40 and 450Hz)The instrument operates at a constant acquisition depth of 2500 points.An LCD TF T screen is used to view the applied signals along with all the setting parameters.The main command functions are accessible using the buttons on the front panel.A graphic interface is used to:-adjust the parameters related to the selected button-navigate using a horizontal main menu showing the current settings andvertical sub-menusChannel IsolationThe two oscilloscope input channels are isolated from each other and from the ground/ earth and the main power supply block. This isolation is provided by double or rein-forced insulation, in compliance with the safety standards IEC 61010-1 and IEC 61010-2-030.This makes it possible to make measurements on installations or systems connected to the electricity supply network for voltages of up to 600V in CAT III. The common mode authorized between the two channels is 600V in CAT III. Thus the operator, the test systems and the environment are completely protected at all times.Any voltage (even dangerous) on one channel will not be present on the other channel. The low points of the inputs are completely insulated, so there is no possibility of the low points looping (which can be dangerous and highly destructive).The oscilloscope is rated 600V CAT III; at least 600V CAT III accessories must be used.Control FeaturesMeasurement Terminals12345109876InputChannel “A”InputChannel “B”External powersupplyUse of the 10:1 ProbesDistribution of stray capacitors:Considering the stray capacitances, it is imperative to correctly connect the reference conductors for each probe The conductors should preferably be connected to the cold points to avoid the transmission of noise by the stray capacitance between modes.The noise of the digital ground (earth) is sent to the analog input by the stray capaci-tance.10:1 Probe CalibrationTo obtain optimum response, the probe’s low frequency compensation must be adjusted.NOTE: T o carry out this adjustment, the two channels of your oscilloscope must be disconnected from the measured circuits before opening the battery housing cover.The calibration output (3Vpp, 1kHz) for the probe is underneath the battery cover.To remove the battery cover, use a coin to turn the slot on the back of the unit counter-clockwise.Connect the probe to be adjustedto the calibration output under thebattery housing cover, as shown.• Select the DC coupling for the channel to which the probe is connected and run an Autosetto carry out pre-setting. • Adjust the sensitivity and the vertical offset of the channel so that the signal fills the screen, and adjust the time base to 200µs to view a signal period on the screen.•Turn the BNC base of the probe in order to access the probe adjustment screw:In this example, the probe is over-compesated:an overshoot occurs.Turn the screw in either direction until thesignal is horizontal and looks like the screenshown opposite. Your probe is now calibrated.Turn the BNC base again to close access tothe adjustment screw and replace the batterycover.Remote ProgrammingThe oscilloscope can be programmed remotely from a computer by using the SX-METRO software, which is located on the CD-ROM supplied with your instrument. This software is used to:• Configure the instrument• Perform measurements and retrieve the results• Transfer files (traces, configuration, screenshots, etc.)To communicate between the instrument and the computer:• Connect the USB end of the cable to one of the PC’s USB ports (if necessary install the driver shipped with the cable).• Connect the optical connector to the oscilloscope, after first powering it up.• Open SX-METRO; select USB communications and wait for communication to be established (in the event of a problem, refer to the SX-METRO instructions).Repair and CalibrationTo ensure that your instrument meets factory specifications, we recommend that it be scheduled back to our factory Service Center at one-year intervals for recalibration, or as required by other standards or internal procedures.For instrument repair and calibration:You must contact our Service Center for a Customer Service Authorization Number (CSA#). This will ensure that when your instrument arrives, it will be tracked and pro-cessed promptly. Please write the CSA# on the outside of the shipping container. If the instrument is returned for calibration, we need to know if you want a standard calibra-tion, or a calibration traceable to N.I.S.T. (Includes calibration certificate plus recorded calibration data).Ship To: Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments15 Faraday DriveDover, NH 03820 USAPhone: (800) 945-2362 (Ext. 360)(603) 749-6434 (Ext. 360)Fax: (603) 742-2346 or (603) 749-6309E-mail:***************(Or contact your authorized distributor)Costs for repair, standard calibration, and calibration traceable to N.I.S.T. are available.NOTE: You must obtain a CSA# before returning any instrument.Technical and Sales AssistanceIf you are experiencing any technical problems, or require any assistance with the proper operation or application of your instrument, please call, mail, fax or e-mail our technical support team:Chauvin Arnoux®, Inc. d.b.a. AEMC® InstrumentsPhone: (800) 945-2362 (Ext. 351) • (603) 749-6434 (Ext. 351) Fax: (603) 742-2346E-mail:********************Limited WarrantyThe Model OX5042 are warranted to the owner for a period of two years from the date of original purchase against defects in manufacture. This limited warranty is given by AEMC® Instruments, not by the distributor from whom it was purchased. This warranty is void if the unit has been tampered with, abused or if the defect is related to service not performed by AEMC® Instruments.Full warranty coverage and registration is available on our website:Please print the online Warranty Coverage Information for your records.What AEMC® Instruments will do:If a malfunction occurs within the warranty period, you may return the instrument to us for repair, provided we have your warranty registration information on file or a proof of purchase. AEMC® Instruments will, at its option, repair or replace the faulty mate-rial.Warranty RepairsWhat you must do to return an Instrument for Warranty Repair:First, request a Customer Service Authorization Number (CSA#) by phone or by fax from our Service Department (see address below), then return the instrument along with the signed CSA Form. Please write the CSA# on the outside of the shipping con-tainer. Return the instrument, postage or shipment pre-paid to:Ship To:Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments15 Faraday DriveDover, NH 03820 USAPhone: (800) 945-2362 (Ext. 360)(603) 749-6434 (Ext. 360)Fax: (603) 742-2346 or (603) 749-6309E-mail:***************Caution: To protect yourself against in-transit loss, we recommend you insure your returned material.You must obtain a CSA# before returning any instrument.12/1899-MAN 100462 v4Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments15 Faraday Drive • Dover, NH 03820 USA • Phone: (603) 749-6434 • Fax: (603) 742-2346。

卡特305.5E2 CR型号的小型氧气挖掘机说明书

卡特305.5E2 CR型号的小型氧气挖掘机说明书

3 3 Triple Flange
Lift Capacities at Ground Level*
10.5 L 9.5 L 63 L 68.3 L 78 L
2.8 gal 2.5 gal 16.6 gal 18 gal 20.6 gal
Hydraulic Sraulics with Variable Displacement Piston Pump
Pump Flow at 2,400 rpm
The Site Reference System included in the COMPASS monitor provides output from pitch and roll sensors to aid in grading and level trenching. This impacts accuracy and productivity for job site finishing.
78.0 in 14.8 in 21.9 in 15.9 in
Cab
Dynamic Operator Sound Pressure Level (ISO 6396:2008)
Exterior Sound Power Level (ISO 6395:2008)*
*European Union Directive “2000/14/EC”
flow sharing capability leading to operational precision, efficient performance and greater controllability. Power on Demand provides optimal efficiency and performance the moment you need it. This automatic system ensures fuel efficiency through appropriate engine rating to meet all operational needs as required.

Thermo Scientific 精密小型重力炉辅助热风炉产品说明书

Thermo Scientific 精密小型重力炉辅助热风炉产品说明书

Precision Compact GravityConvection OvensModel No.PR305215G,PR305210G,PR305210GCNPR305225G,PR305220G,PR305220GCNLTM1879X1•8/4/09T able of Contents Introduction (3)Product Overview (3)Safety Information (4)Alert Signals (4)Specifications (5)Power Requirements (5)Overall Dimensions (5)Chamber Dimensions (5)Volume (5)Shipping Weight (5)Performance Characteristics (5)Environmental Operating Conditions (5)Unpacking and Installation (6)Shipping Carton (6)Location (6)Electrical Requirements (6)Installation (7)Operation (8)Start-Up (8)Maintenance (9)Replacement Parts (10)Wiring Diagrams (11)Ordering Procedures (14)Warranty (16)2Introduction4These instructions contain important operating and safety information.The user must carefully read and understand these instructions before using the oven.Y our unit has been designed to optimize function,reliability,safety and ease of use.It is the user’s responsibility to install the oven in conformance with local electrical codes.SafetyInformationWarningWarnings alert you to a possibility of personal injury.CautionCautions alert you to a possibility of damage to the equipment.NoteNotes alert you to pertinent facts and conditions.Hot SurfaceHot surfaces alert you to a possibility of personal injury if you come in contact with a surface during use or for a period of time after use.Alert SignalsSpecificationsUnpacking and InstallationNoteLeave unit disconnected when not in use.6U NPACKING AND I NSTALLATION7NoteIf the equipment is used in specified by the tion provided by the impared.OperationWarningDo not use in the mable or combustible materials or explosive gases.Do not use in the presence of pressurized or sealed containers –fire or explosion may result,causing death or severe injury.WarningDo not heat any substance above a temperature that will cause it to emit toxic fumes;death or severe injury may result.CautionIt is the user’s responsibility to mon-itor oven action when setting and maintaining operating temperature;oven failure may occur with possi-ble property damage and/or injury to personnel.Status LampCon t rol P o w er S wi t c hControl PanelWarningT o avoid electrical short or shock,do not allow any metal object to pro-trude into the space beneath the shelf that serves as the heater shield inside the oven.In addition,do not operate oven with the shield removed.Hot SurfaceAt the higher temperatures,the exte-rior of the oven and particularly the thermometer vent ring on the top become uncomfortably warm to the touch.To avoid burns,do not touch these surfaces.8MaintenanceBecause of their rugged,simple construction,these ovens require very little maintenance.Ordinary cleaning will suf-fice.The bottom shelf that covers the heater can be removed for easy access to the heater area.Clean up any spills as soon as possible to prevent materi-als being baked on surfaces.When the oven is cool,use a mild soap and water to clean surfaces.Rinse thorough-ly and dry.It is best to avoid highly abrasive cleaners that can damage the finish of the interior surfaces and shelves.If the oven fails to heat,there may be several possible causes:•Oven is not receiving electrical power.•Heater is burned out.•Thermostat is malfunctioning.Have a qualified electrical technician determine the cause of the problem and make the necessary repairs.Y our local Thermo Scientific products dealer can provide the service and replacement partsneeded.WarningDisconnect from the power supply prior to maintenance and servicing.NoteMake no attempt to service or repair a Thermo Scientific product under warranty before consulting your Thermo Scientific dealer.After the warranty period,such consultation is still advised,especially when the repair may be technically sophisticat-ed or difficult.If assistance is needed beyond what the distributor can pro-vide,please call Customer Service at 800-553-0039.No merchandiseshould be returned directly to the fac-tory without obtaining a ReturnMaterials Authorization (RMA)num-ber from CustomerService.9Replacement Parts DESCRIPTION PART NUMBER Tension Catch:600-124-00 Handle:560-248-00 Feet:790-225-00 Status Lamp Base:360-233-01 Status Lamp Lens(amber):360-235-00 Power Switch(120V):SWX143 Power Switch(240V):440-292-00 Thermometer Grommet:790-247-00 Thermometer Holder:910-039-00 Control Thermostat:920-412-00 Thermostat Knob:560-265-00Hi-Limit Thermostat:920-413-00 Heaters:PR305215G:340-212-00PR305225G:340-213-00PR305210G,PR305210GCN:340-214-00PR305220G,PR305220GCN:340-215-00 Shelves Kit:PR305215G,PR305210G,PR305210GCN:3510-8QPR305225G,PR305220G,PR305220GCN:3511-8Q10Wiring DiagramsOrdering ProceduresPlease refer to the Specification Plate for the completemodel number,serial number,and series number whenrequesting service,replacement parts or in any corre-spondence concerning this unit.All parts listed herein may be ordered from the ThermoScientific dealer from whom you purchased this unit orcan be obtained promptly from the factory.When serviceor replacement parts are needed we ask that you checkfirst with your dealer.If the dealer cannot handle yourrequest,then contact our Customer Service Departmentat563-556-2241or800-553-0039.Prior to returning any materials,please contact ourCustomer Service Department for a“Return MaterialsAuthorization”number(RMA).Material returned withoutan RMA number will be refused.12One Y ear Limited Warranty This Thermo Scientific product is warranted to be free of defects in materials and workmanship for one(1) year from the first to occur of(i)the date the product is sold by the manufacturer or(ii)the date the product is purchased by the original retail customer(the“Commencement Date”).Except as expressly stated above,the MANUFACTURER MAKES NO OTHER WARRANTY,EXPRESSED OR IMPLIED,WITH RESPECT TO THE PRODUCTS AND EXPRESSL Y DISCLAIMS ANY AND ALL WARRANTIES,INCLUDING BUT NOT LIMITED TO,WARRANTIES OF DESIGN,MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE.An authorized representative of the manufacturer must perform all warranty inspections.In the event of a defect covered by the warranty,we shall,as our sole obligation and exclusive remedy,provide free replace-ment parts to remedy the defective product.In addition,for products sold within the continental United States or Canada,the manufacturer shall provide free labor to repair the products with the replacement parts,but only for a period of ninety(90)days from the Commencement Date.The warranty provided hereunder shall be null and void and without further force or effect if there is any(i) repair made to the product by a party other than the manufacturer or its duly authorized service representa-tive,(ii)misuse(including use inconsistent with written operating instructions for the product),mishandling, contamination,overheating,modification or alteration of the product by any customer or third party or(iii)use of replacement parts that are obtained from a party who is not an authorized dealer of Thermo Scientific prod-ucts.Heating elements,because of their susceptibility to overheating and contamination,must be returned to the factory and if,upon inspection,it is concluded that failure is due to factors other than excessive high tempera-ture or contamination,the manufacturer will provide warranty replacement.As a condition to the return of any product,or any constituent part thereof,to the factory,it shall be sent prepaid and a prior written authorization from the manufacturer assigning a Return Materials Number to the product or part shall be obtained.IN NO EVENT SHALL THE MANUFACTURER BE LIABLE TO ANY P ARTY FOR ANY DIRECT,INDIRECT, SPECIAL,INCIDENTAL,OR CONSEQUENTIAL DAMAGES,OR FOR ANY DAMAGES RESULTING FROM LOSS OF USE OR PROFITS,ANTICIPATED OR OTHERWISE,ARISING OUT OF OR IN CONNECTION WITH THE SALE,USE OR PERFORMANCE OF ANY PRODUCTS,WHETHER SUCH CLAIM IS BASED ON CONTRACT,TORT(INCLUDING NEGLIGENCE),ANY THEORY OF STRICT LIABILITY OR REGULATORY ACTION.For the name of the authorized Thermo Scientific product dealer nearest you or any additional information,contact us:2555Kerper Blvd.,Dubuque,Iowa,52004-0797Phone:563-556-2241or1-800-553-0039Fax:563-589-0516Web:13。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

9
®NIC COMPONENTS CORP. ww www www www Surface Mount Aluminum Electrolytic Capacitors NACEN Series FEATURES
•CYLINDRICAL V-CHIP CONSTRUCTION FOR SURFACE MOUNTI •NON-POLARIZED, 2000 HOURS A T 85O C •5.5mm HEIGHT
•ANTI-SOLVENT (2 MINUTES)•DESIGNED FOR REFLOW SOLDERING CHARACTERISTICS MAXIMUM PERMISSIBLE RIPPLE CURRENT (mA rms AT 120Hz AND 85O C)STANDARD PRODUCT AND CASE SIZE TABLE DXL (mm)*Denotes values available in optional 10% tolerance
UNTING
RoHS
Compliant
includes all homogeneous materials
*See Part Number System for Details
NACEN 100 M 16V 5x5.5 TR 13 F RoHS Compliant 97% Sn (min.), 3% Bi (max.) 330mm (13”) Reel Tape & Reel Size in mm Working Voltage T olerance Code M=20%, K=10% Capacitance Code in µF , fi rst 2 digits are signifi cant Third digit is no. of zeros, “R” indicates decimal for values under 10µF Series PART NUMBER SYSTEM 0.3mm max.D φL
I I W
P
A
B
DIMENSIONS (mm)
Case Size D φ±0.5L max.A/B±0.2I ± 0.2W P±0.24x5.5 4.0 5.5 4.3 1.80.5 ~ 0.8 1.05x5.5 5.0 5.5 5.3 2.10.5 ~ 0.8 1.46.3x5.5 6.3 5.5 6.6 2.50.5 ~ 0.8 2.2PRECAUTIONS Please review the notes on correct use, safety and precautions found on pages T10 & T11 of NIC’s Electrolytic Capacitor catalog .
Also found at /precautions
If in doubt or uncertainty, please review your specifi c application - process details with
NIC’s technical support personnel: tpmg@
Rated Voltage Rating 6.3 ~ 50Vdc
Rated Capacitance Range 0.1 ~ 47µF
Operating Temperature Range -40° ~ +85°C
Capacitance Tolerance ±20%(M), ±10%(K)*
Max. Leakage Current After 1 Minutes at 20°C 0.03CV +6µA maximum
Max. Tan δ @ 120Hz/20°C W.V . (Vdc) 6.31016253550
Tan δ @ 120Hz/20°C 0.240.200.170.170.150.15
Low Temperature Stability (Impedance Ratio @ 120Hz)W.V . (Vdc) 6.31016253550
Z-40°C/Z +20°C 432222Z-40°C/Z +20°C 884433
Load Life T est at Rated W.V .85°C 2,000 Hours (Reverse polarity every 500 hours)Capacitance Change Within ±25% of initial measured value
Tan δLess than 200% of specifi ed value Leakage Current Less than specifi ed value
Cap.
(µF)Code Working Voltage (Vdc)
6.31016253550
0.1R10-----4x5.5
0.22R22-----4x5.5
0.33R33-----4x5.5*
0.47R47-----4x5.5
1.01R0-----4x5.5*
2.22R2----4x5.5*5x5.5*
3.33R3---4x5.5*5x5.5*5x5.5*
4.74R7--4x
5.55x5.5*5x5.5*
6.3x5.5
10100-4x5.5*5x5.5* 6.3x5.5* 6.3x5.5* 6.3x5.5*
222205x5.5* 6.3x5.5* 6.3x5.5*---
33330 6.3x5.5* 6.3x5.5* 6.3x5.5*---
47470 6.3x5.5*-----
Cap. (µF)Working Voltage (Vdc)6.310162535500.1----- 1.00.22----- 2.30.33----- 3.50.47----- 5.01.0-----102.2----8.4153.3---1017184.7--1219202310-172528302322313539---33394357---4747-----元器件交易网。

相关文档
最新文档