HP ILO配置手册
HP ilo 100i使用手册
HP ProLiant Lights-Out 100 Remote Management User Guidefor HP ProLiant ML110 G4, ProLiant ML115 G1, ProLiant ML150 G3, ProLiant DL140 G3, and ProLiant DL145 G3 ServersPart Number 419106-004March 2007 (Fourth Edition)© Copyright 2006, 2007 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license.Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation. Windows Server 2003 is a U.S. trademark of Microsoft Corporation. Java is a U.S. trademark of Sun Microsystems, Inc.Audience assumptionsThis document is for the person who installs, administers, and troubleshoots servers and storage systems.HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.ContentsOperational overview (5)User guide overview (5)Server management (5)Server management features (5)LO100 standard features (6)LO100 optional features (6)Installation (7)Remote management card kit contents (7)Pre-installation procedures (7)Installing the remote management card (8)Post-installation procedures (8)Configuration (9)Configuring network access (9)Establishing user accounts (9)Using the serial port (10)Enabling serial access to the LO100 (10)LO100 serial port configuration (11)Using TCP/IP over Ethernet management port (11)Selecting an Ethernet management port (11)Obtaining a DHCP IP address from the BIOS Setup Utility (12)Setting up a static IP address from the BIOS Setup Utility (12)Enabling telnet and HTTP services (13)Updating the firmware (13)Updating the firmware remotely (14)Flashing previous firmware versions on a ProLiant ML150 G3 or ML110 G4 server (15)Using LO100 (16)New features (16)Using SSL (16)Using SSH (17)Using CLP (18)CLP syntax (18)Base commands (19)Specific commands (23)IPMI 2.0 support (23)Logging in to LO100 (24)Logging in through a web browser (24)Logging in through the CLP (24)Browser main menu options (25)Controlling server power remotely (26)Controlling server power from a browser (26)Controlling server power through the CLP (27)Monitoring sensors (27)Viewing sensors data from a web browser (27)Viewing sensor data from the BIOS Setup Utility (28)Platform event filtering configuration (28)Using the system event log (29)Accessing the system event log from a web browser (30)Accessing the system event log from the CLP (30)Accessing the system event log from the BIOS Setup Utility (31)Using Virtual KVM (31)Using the remote graphic console (32)System buttons (35)Using Virtual Media (36)Adding a virtual media device (37)Shared virtual media devices (37)Accessing the remote console through telnet (38)BIOS console text redirection through telnet (38)Linux console redirection (39)Microsoft Windows EMS management (41)Hardware Inventory page (42)User administration (42)Changing user settings through a web browser (43)Changing user settings through the CLP (43)Network settings (44)Configuring network settings using a web browser (44)Configuring network settings using the CLP (44)Configuring network settings using the BIOS Setup Utility (45)Platform event trap configuration (47)Installing a license key (47)Importing a certificate (48)Creating a certificate (48)Installing a certificate or private key through a web browser (49)Installing a certificate or private key through the CLP (50)HP SIM support (50)Acronyms and abbreviations (51)Index (54)Operational overviewIn this sectionUser guide overview (5)Server management (5)Server management features (5)User guide overviewThis guide discusses the standard and optional operational features of the LO100 used in HP ProLiantML110 G4, ProLiant ML115 G1, ProLiant DL140 G3, ProLiant DL145 G3, and ProLiant ML150 G3servers.Server managementHP ProLiant Lights-Out 100 delivers basic remote control of vital server resources, supports IPMI 2.0, and provides system administrators with access to the server at any time, even before an operating system is installed on the server.HP ProLiant Lights-Out 100 provides text mode console redirection, DMTF SMASH compliant commandline interface, and browser access to many of the same system management functions. You can accessLO100 through a dedicated Ethernet port or through the server serial port.Server management featuresWith HP ProLiant Lights-Out 100, you can perform the following tasks:•Access a remote graphic console (Virtual KVM)•Access the serial console of the host operating system over the network using standards-based client utilities•Switch between serial console redirection or the LO100 command line interface•Communicate securely using SSL and SSH•Remotely control the power button of the server (power on and off the server), or perform warm or cold server reboots•Remotely monitor fan speed and system power state (S0 or S5)•Access the system event log•Access virtual media•Configure TCP/IP settings for the LO100 NIC•Control user access•Discover, identify, and launch LO100 from HP SIM•Access LO100 and server controls using a standard browser or new industry-standard SMASH CLP command line interface•Access command line help•Manage the server with IPMI 2.0 compliant applications•Access telnetNot all of the features displayed and described in the guide are available on all systems. To verify which features are supported on your system, see "LO100 standard features (on page 6)" and "LO100 optional features (on page 6)" for more information.LO100 standard featuresIn-band IPMI 2.0 elements available through the operating system are a standard feature of HP ProLiantML115 G1, ProLiant ML110 G4, and ProLiant ML150 G3 servers.The standard features of HP ProLiant DL140 G3 and ProLiant DL145 G3 servers include the following:•In-band IPMI 2.0 elements available through the operating system•Web browser access (HTTP) to power control, system event log, hardware status, and license key activation of optional features•SMASH CLP interface access to remote power control, system event log, hardware status, and operatingsystem serial consoleLO100 optional featuresHP ProLiant ML115 G1, ProLiant ML110 G4, and ProLiant ML150 G3 server optional features areactivated with installation of the HP Lights-Out 100c Remote Management Card and include the following: •Support for SSL, SSH, and IPMI 2.0 security with factory-default self-signed certificates and keys•Support for imported certificates•Virtual media access•Remote graphic console (Virtual KVM) acessHP ProLiant DL140 G3 and ProLiant DL145 G3 server optional features are activated with the purchase of an optional features package. Two feature packages are available:•The Lights-Out 100i Select Pack includes the following features:o Support for SSL, SSH, and IPMI 2.0 security with factory-default self-signed certificates and keyso Support for imported certificateso Virtual media access•The Lights-Out 100i Advanced Pack includes the following features:o All features in the Lights-Out 100i Select Packo Virtual KVMInstallationIn this sectionRemote management card kit contents (7)Pre-installation procedures (7)Installing the remote management card (8)Post-installation procedures (8)Remote management card kit contentsInstallation of the HP Lights-Out 100c Remote Management Card is required to activate the optionalfeatures of the HP ProLiant ML115 G1, ProLiant ML110 G3, and ProLiant ML150 G3 servers. See"LO100 optional features (on page 6)" for more information.The HP ProLiant Lights-Out 100c Remote Management Card Kit includes the following components:•HP Lights-Out 100c Remote Management Card•Spacer support•Remote management card installation instructionsPre-installation proceduresThe installation procedures in this document are intended for individuals who are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.WARNING: Failure to properly turn off the server before you open the server may causeserious damage to the equipment as well as bodily harm.CAUTION: Follow the ESD precautions listed in your server guide when handling the remotemanagement card.IMPORTANT: Observe the pre- and post-configuration procedures described in later sectionswhen installing the remote management card.NOTE: The procedures described in this section assume that the server is positioned on a flat, stable surface.1.Back up the server data.2.Shut down the operating system as outlined in the operation system instructions.3.Power off the server and all the peripherals connected to it.4.Unplug all cables from the power outlets to avoid exposure to high energy levels that can causeburns when parts are short-circuited by metal objects such as tools or jewelry.bel each cable, if not already labeled, to expedite reassembly.6.Disconnect telecommunication cables to avoid exposure to shock hazard from ringing voltages.7.Open the server according to the instructions described in your server manual. Installing the remote management card1.Remove the access panel.2.Carefully lay the server on its unexposed side to gain access to the system board.3.Locate the remote management card connectors on the system board.4.Install the remote management card in the connectors on the system board.Post-installation procedures1.Be sure all components are installed according to the "Pre-installation procedures (on page 7)."2.Be sure you have not left any loose tools or parts inside the server.3.Reinstall any expansion boards, peripherals, board covers, and system cables previously removed.4.Reinstall the system covers.5.Connect all external cables and the AC power cord to the system.6.Press the power button on the front panel to turn on the server.ConfigurationIn this sectionConfiguring network access (9)Establishing user accounts (9)Using the serial port (10)Using TCP/IP over Ethernet management port (11)Updating the firmware (13)Configuring network accessThe server is connected to the network using a standard Ethernet cable. Through this connection, you can access the remote management CLP, verify POST remotely, and access the BIOS Setup Utility remotely.To configure network access:1.Connect a standard Ethernet cable from the LO100 to a network jack.o On HP ProLiant ML150 G3 and ProLiant ML110 G4 servers, connect the NIC port on the remote management card.o On HP ProLiant DL140 G3 and ProLiant DL145 G3 servers, connect the onboard LO100 NIC.2.Obtain the DHCP IP address by using one of the following methods:o Look at the DHCP clients table.o Press the F10 key during POST, and read the IP address from BIOS Setup Utility underAdvanced/IPMI/LAN Setting. See "Obtaining a DHCP IP address from the BIOS Setup Utility (onpage 12)" for more information.By default, LO100 has DHCP enabled and automatically negotiates an IP address.ing the DHCP IP address, use telnet to log in to the remote management CLP, or use a webbrowser to access the HTML interface.To set up a static IP address, see "Setting up a static IP address from the BIOS Setup Utility (on page 12)"for more information.Establishing user accountsLO100 supports four accounts types, with varying levels of permissions to view and control features. Formore information on user accounts, see the "User administration (on page 42)" section. Two accounts are available by default, one of type administrator and one of type operator.The administrator account enables the user to execute the full set of CLP commands and changemanagement processor configuration. The default administrator account user name is admin, and thedefault password is admin.The operator account enables the user to execute common commands and functions but restricts access to specific functions, such as adding and changing user account information and changing the configurationof the management processor. HP recommends logging in with the operator account to perform common functions. The default user name is Operator, and the default password is Operator.For more information on how to log in to LO100, see the "Logging in to LO100 (on page 24)" section. Using the serial portThe server serial port provides basic serial port functionality and serves as an interface to LO100. Youcan configure the system serial port for exclusive use with LO100.CAUTION: After enabling the serial port for use with LO100, legacy serial devices might notfunction correctly if attached to the serial port.You must configure the LO100 serial port hardware parameters to work with your respective serial portcommunications software. LO100 serial port configuration is controlled through the BIOS Setup Utility. Enabling serial access to the LO1001.Power up the server.2.When POST displays the message, ROM-Based Setup, press the F10 key. If the server has anadministrator password configured, the system prompts you to enter the password. If the server doesnot have a password configured, the main screen of the BIOS Setup Utility appears.3.Press the right arrow (→) key to navigate to the Advanced menu.o On HP ProLiant ML110 G4 and ProLiant ML150 G3 servers:a.Press the down arrow (↓) key to scroll to IPMI. Press the Enter key.b.Press the down arrow (↓) key to scroll to Serial Port Assignment. Press the Enter key to togglebetween System and BMC. Select System.c.Press the down arrow (↓) key to scroll to Serial Port Switching. Select Enabled.d.Press the down arrow (↓) key to scroll to Serial Port Connection Mode. Select Direct.e.Press the Esc key to return to the Advanced menu.f.Press the down arrow (↓) key to scroll to IO Device Configuration. Press the Enter key.g.Select Serial Port A, and press the Enter key to toggle between Enabled and Disabled. SelectEnabled.o On HP ProLiant ML115 G1 servers:a.Press the down arrow (↓) key to scroll to the Serial Port Configuration menu. Press the Enter key.b.Press the down arrow (↓) key to scroll to Serial Port Assignment. Press the Enter key to togglebetween System and BMC. Select System.c.Press the down arrow (↓) key to scroll to Serial Port Switching. Select Enabled.d.Press the down arrow (↓) key to scroll to Serial Port Connection Mode. Select Direct.e.Press the Esc key to return to the Advanced menu.f.Press the down arrow (↓) key to scroll to IO Device Configuration. Press the Enter key.g.Select Serial Port 1 and press the Enter key to toggle between Enabled and Disabled. SelectEnabled.o On HP ProLiant DL140 G3 servers:a.Press the down arrow (↓) key to scroll to IO Device Configuration. Press the Enter key.b.Press the down arrow key (↓) to scroll to the Serial Port menu. Press the Enter key to togglebetween Serial, Shared, and BMC. Select Shared.c.Press the down arrow (↓) key to scroll to Serial Port A. Select Enabled.d.Press the Esc key to return to the Advanced menu.e.Press the down arrow (↓) key to scroll to IPMI. Press the Enter key.f.Confirm the following settings:—BMC Telnet Service: [Enabled]—BMC Ping Response: [Enabled]—BMC HTTP Server: [Enabled]o On HP ProLiant DL145 G3 servers:a.Press the down arrow (↓) key to scroll to IO Device Configuration. Press the Enter key.b.Press the down arrow key (↓) to scroll to the Serial Port menu. Press the Enter key to togglebetween Serial, Shared, and BMC. Select Shared.c.Press the down arrow (↓) key to scroll to Serial Port A. Select Enabled.d.Press the Esc key to return to the Advanced menu.4.Press the F10 key to save and exit.LO100 serial port configuration1.Power on the server by pressing the Power On/Off button on the front panel.2.When POST displays the message, ROM-Based Setup, press the F10 key. If the server has anadministrator password configured, the system prompts you to enter the password. If the server doesnot have a password configured, the main screen of the BIOS Setup Utility appears.3.Press the right arrow (→) key to navigate to the Advanced menu.4.Press the down arrow (↓) key to scroll to the Console Redirection menu.5.Press the Enter key to toggle between Enabled and Disabled. Select Enabled for the consoleredirection option.6.Review the serial port settings, and be sure the settings match the serial port communicationssoftware settings used to connect to LO100.7.Press the Esc key to return to the previous screen, or press the F10 key to save the changes and exitSetup.Using TCP/IP over Ethernet management portThe LO100 LAN port can be accessed from two different Ethernet ports: the dedicated 10/100 LO100management port or through a side-band connection with the second LOM (NIC2). Selecting an Ethernet management portTo select either the LO100 or side-band connection:1.Power on the server by pressing the Power On/Off button on the front panel.2.When POST displays the message, ROM-Based Setup, press the F10 key. If the server has anadministrator password configured, the system prompts you to enter the password. If the server doesnot have a password configured, the main screen of the BIOS Setup Utility appears.3.Press the right arrow (→) key to navigate to the Advanced menu.4.Press the down arrow (↓) key to scroll to NIC Option. Press the Enter key to select between thededicated or side-band connection.5.Press the Esc key to return to the previous screen, or press the F10 key to save the changes and exitSetup.The dedicated TCP/IP over Ethernet management port, whether dedicated or shared, is a standardEthernet 10/100Mb interface that is connected to the network using a standard Ethernet cable. Beforeusing the dedicated management port, you must determine the DHCP IP address, set a static IP address,or use the default static IP address.Obtaining a DHCP IP address from the BIOS Setup UtilityBy default, LO100 has DHCP enabled and automatically negotiates an IP address. To view the DHCP IP address, run the BIOS Setup Utility or retrieve the DHCP IP address using CLP through the serial portconnection. To view the DHCP IP address using the BIOS Setup Utility:1.Power on the server by pressing the Power On/Off button on the front panel.2.When POST displays the message, ROM-Based Setup, press the F10 key. If the server has anadministrator password configured, the system prompts you to enter the password. If the server doesnot have a password configured, the main screen of the BIOS Setup Utility appears.3.Press the right arrow (→) key to navigate to the Advanced menu.4.Press the down arrow (↓) key to scroll to IPMI. Press the Enter key.5.To obtain the DCHP IP address:o On HP ProLiant ML110 G4 and ProLiant ML150 G3 servers, press the down arrow (↓) key to scroll to the end of the menu to display the DHCP IP address.o On HP ProLiant ML115 G1 servers:a.Press the down arrow (↓) key to scroll the BMC LAN Configuration menu. Press the Enter key.b.Press the down arrow (↓) key to scroll to the end of the menu to display the DHCP IP address.o On HP ProLiant DL140 G3 and DL145 G3 servers:a.Press the down arrow (↓) key to scroll to the LAN Settings submenu. Press the Enter key.b.Note the DHCP assigned IP address for future reference.c.Press the Esc key to return to the previous screen, or press the F10 key to save the changes andexit Setup.To configure or change your network settings, see "Network settings (on page 44)" for more information. Setting up a static IP address from the BIOS Setup UtilityBy default, LO100 has DHCP enabled and automatically negotiates an IP address. To disable DHCP and enable a static IP address:1.Press the F10 key during POST to enter the BIOS Setup Utility.2.Press the right arrow (→) key to navigate to the Advanced menu.3.Press the down arrow (↓) key to scroll to IPMI. Press the Enter key.4.To set your network BIOS settings:o On ProLiant ML110 G4 and ML150 G3 servers:a.Press the down arrow (↓) key to scroll to the end, and select DHCP IP Source.b.Set DHCP IP Source to Disabled.c.Press the down arrow (↓) key to scroll down and enter a valid IP address, subnet mask, andgateway address (press the Tab key to move between address fields).o On ProLiant ML115 G1 servers:a.Press the down arrow (↓) key to scroll to the BMC LAN Configuration menu. Press the Enter key.b.Press the down arrow (↓) key to scroll to the end, and select DHCP IP Source.c.Set DHCP IP Source to Disabled.o On ProLiant DL140 G3 and ProLiant DL145 G3 servers:a.Press the down arrow (↓) key to scroll to the LAN Settings submenu. Press the Enter key.b.Set the IP Address Assignment to Static. This setting enables you to modify a static IP addressthrough the BIOS Setup menu.c.Press the down arrow (↓) key to scroll down and enter a valid IP address, subnet mask, andgateway address (press the Tab or period (.) key to move between address fields).5.Press the F10 key to save and exit.To restore DHCP, see "Configuring network settings using the BIOS Setup Utility (on page 45)." Enabling telnet and HTTP servicesOn ProLiant ML110 G4, ProLiant ML115 G1, and ProLiant ML150 G3 servers, HTTP and telnet areautomatically enabled after installing the HP ProLiant Lights-Out 100c Remote Management Card. OnProLiant DL145 G3 servers, HTTP and telnet are automatically enabled.On ProLiant DL140 G3 servers:1.Press the F10 key during POST to enter the BIOS Setup Utility.2.Press the right arrow (→) key to navigate to the Advanced menu.3.Press the down arrow (↓) key to scroll to IPMI. Press the Enter key.4.Press the down arrow (↓) key to scroll to the following settings, and set the parameters as needed(the following example shows configuring for LO100 access using telnet and a web page):o BMC Telnet Service: [Enabled]o BMC Ping Response: [Enabled]o BMC HTTP Server: [Enabled]Updating the firmwareTo update the LO100 firmware, use the ROMPaq utility. Downloads for the ROMPaq utility are available on the HP website (/support). For more information about using the ROMPaq utility, refer to the HP website (/servers/manage).NOTE: LO100 does not support ROMPAQ flashing from a virtual floppy.After the ROMPaq utility flashes the selected device, cycle power manually to reboot the operatingsystem.Updating the firmware remotelyIf you want to update the LO100 firmware remotely, you can use the load command. The firmware filemust be an uncompressed firmware image file created using the DOS ROMPAQ utility found on the Lights-Out 100 Firmware Upgrade Diskette Utility, which is available for download from the HP website(/servers/lights-out).To create an uncompressed image file, enter the following command at the DOS prompt:ROMPAQ /D <infile> <outfile>where <infile> is the ROMPAQ firmware image file and <outfile> is the file name for theuncompressed binary image file. For example:ROMPAQ /D cpqq0801.D14 ldrImage.binROMPAQ Firmware Upgrade Utility, Version 5.02 (R)Copyright (c) Hewlett-Packard Corporation, 1994-2006Input file: CPQQ0801.D14Output file: LDRIMAGE.BINThe load command is used to take a binary image from a specific source location (specified as a URL)and place it at the specified target address.The load command can download and flash an ldr firmware image file using TFTP from the specifiedlocation.Flashing the firmware using TFTP settings on Windows®:1.Copy the BMC firmware into a directory on the server.2.Run TFTP by launching the executable file tftpd32.exe.3.Navigate to TFTP configuration>Settings and set Timeout to 30 seconds and Max Retransmit to 6.4.Enter File Name and TFTP Server IP Address. File Name is the path where the BMC firmware isresiding. TFTP Server IP Address is the IP address of the TFTP server (for example, 10.141.38.157).Flashing the firmware using TFTP settings on Linux:1.Navigate to Applications>Systems Settings>Server Settings>Services and make sure that TFTP andxinetd are running.2.Open the file /etc/xinetd.d/tftp and modify the parameter server_args to include -T15000000. For example, server_args = -c -s /tftpboot -T 15000000.3.If a firewall is enabled, disable it or modify the settings to allow the firewall to connect to the TFTPport. To change the firewall settings, navigate to Applications>System Settings>Security Level andenter 69:udp in other ports.To update the firmware, log in to LO100 as administrator through the CLP interface and issue the loadcommand to upload and install the firmware from the map1/firmware directory.1.Start a CLP session. To access CLP:a.Navigate to Start>All Programs>Accessories>Command Prompt.b.At the command prompt, enter telnet <IP address>.2.At the CLP prompt, enter /map1/firmware.3.At the CLP prompt, enter load -source <URI> -oemhpfiletype csrwhere:o<URI> is the //tftp server IP/filename to be downloaded.o tftp server IP is the URL or IP address of the TFTP server containing the firmware.o filename is the file name of the image file (LdrImage.bin in this example).For Example, on ProLiant ML150 G3 and ProLiant ML110 G4 servers, enter load -source//10.141.38.157/LdrImage.bn1 - oemhpfiletype csr.For Example, enter load -source //10.141.38.157/LdrImage.bin - oemhpfiletypecsr.The TFTP application might report an error during the early part of the firmware upload processduring the firmware image validation process. An error does not necessarily indicate failure of thefirmware upload and will not prevent successful firmware uploads. A successful firmware uploadtypically takes several minutes. After the firmware upgrade process is complete, verify that the newversion of the firmware is active.If you think the firmware upgrade process failed after allowing sufficient time to complete (at least 5minutes), reboot the server, and verify that the previous version of the firmware is still active. Alwaysreboot the server before retrying the firmware upgrade process.After installing the firmware, the IP address of the server might reset to the default value. You mustlocally reset the IP address to the desired address.NOTE: After using the load command LO100 will reset ending your CLP interface session.You must reconnect to the CLP interface.NOTE: When you use the CLP load command with TFTPD32, HP recommends using a 30-second timeout and 6 retries.Flashing previous firmware versions on a ProLiant ML150 G3 or ML110 G4 serverWhen an HP Lights-Out 100c Remote Management Card is installed in a ProLiant ML150 G3 server orProLiant ML110 G4 server and you want to flash the LO100 back to an earlier version, you must enter the CLP command oemhp i 20 20 c0 18 00 04 04 e0 in the map1 directory to ensure that theprevious version is reactivated.。
Hp服务器配置ilo方法
Hp服务器配置ilo方法Hp服务器配置ilo方法1·确认ilo级别1·1 登录服务器操作系统1·2 打开浏览器,并输入ilo管理地质1·3 输入ilo用户名和密码,登录ilo界面 1·4 在ilo管理界面查看ilo级别,记录下来2·更新ilo固件2·1 最新的ilo固件升级包2·2 解压缩升级包2·3 在ilo管理界面选择“固件升级”2·4 “浏览”,选择解压缩后的固件文件2·5 “”按钮,开始升级2·6 确认升级成功后,重启服务器3·配置Ilo网络设置3·1 在ilo管理界面选择“网络”3·2 “配置”按钮,进入网络配置页面3·3 根据实际情况填写相关网络信息,如IP地质、子网掩码、默认网关和DNS服务器3·4 “保存”按钮,保存配置信息4·配置ilo用户和权限4·1 在ilo管理界面选择“用户”4·2 “添加”按钮,进入添加用户页面4·3 填写用户信息,包括用户名、密码和权限级别4·4 “保存”按钮,保存用户配置5·配置ilo警报通知5·1 在ilo管理界面选择“警报通知”5·2 “添加”按钮,进入添加警报通知页面5·3 填写警报通知信息,包括接收警报的邮箱地质5·4 “保存”按钮,保存警报通知配置6·配置ilo电源管理6·1 在ilo管理界面选择“电源管理”6·2 根据需求,设置服务器开机自启动、关机和重启选项6·3 “保存”按钮,保存电源管理配置7·配置ilo远程控制7·1 在ilo管理界面选择“远程控制”7·2 根据需求,配置远程控制功能,如启用虚拟媒体、虚拟控制台和KVM功能7·3 “保存”按钮,保存远程控制配置8·配置ilo事件日志8·1 在ilo管理界面选择“事件日志”8·2 根据需求,设置事件日志记录级别和事件日志保存周期8·3 “保存”按钮,保存事件日志配置9·配置ilo时间和日期9·1 在ilo管理界面选择“日期和时间”9·2 根据需求,设置时区和时间同步方式9·3 “保存”按钮,保存时间和日期配置10·保存配置并重启10·1 在ilo管理界面“保存配置”,保存所有配置更改10·2 确认所有配置生效后,重启服务器本文档涉及附件:无本文所涉及的法律名词及注释:无。
HP服务器远程管理软件iLO使用介绍
HP服务器远程管理软件iLO使用介绍iLO 是一组芯片,内部是vxworks的嵌入操作系统,在服务器的背后有一个标准RJ45口对外连接生产用交换机或者带外管理的交换机. iLO自己有处理器,存储和网卡,默认网卡配置是DHCP,可以在服务器启动的时候进入iLO 的ROM based configuration utility 修改. 服务器的面板左侧,会有一个白色的纸吊牌,上面写着iLO 网卡上的DNS name和Password. 请勿随便更改,更改了不要遗失.iLO的使用很简单. 用网线把iLO口和你的LAN switch或者专门的OB switch 相连. 如果你准备让iLO 默认方式工作,你需要有一个LAN内的DHCP和DNS 服务器存在. 如果你在服务器启动的时候修改dhcp 到static ip,就无所谓了. 在你的笔记本或者pc上,开一个IE(支持java),然后地址那里书写 iLO DNS name(写在纸吊牌上的,你需要DHCP DNS 服务器在局域网内). 就可以看到iLO界面了. 或者直接填写iLO的ip地址也可以.iLO界面除了报告一些硬件信息之外,主要提供了三大类控制:第一类是Virtual console,就是类似pc anywhere 的远程控制了,但是和软件的控制不一样,它是完全硬件级的,哪怕你的服务器没有操作系统,或者硬盘损坏,或者重新启动,都可以完整的进行控制,所以除非更换被管理服务器的硬件,正常的操作都可以用iLO来做,根本不用进入机房.(当然得保证网络通畅).第二类是 Virtual power,虚拟电源,模拟所有的电源开关动作,比如按住不放,按住就放等等...第三类是Virtual media,虚拟介质,你可以将pc或者笔记本上的光驱软驱,通过LAN虚拟给被管理的服务器。
这个主要是用来安装操作系统,或者传输数据,打补丁之类的。
比如那个被管理服务器是新的,没有操作系统,硬盘也没有作阵列,我怎么结合上面的三类控制手段来操作呢?1. 用virtual power重启动服务器2. 用virtual console 远程操作服务器,在服务器启动的POST时候,进入服务器的Smart array 6i Rom based utility 进行阵列配置3. 用virtual console 远程操作服务器,在服务器POST完毕的结束阶段,F9进入系统的BIOS,我们行话叫RBSU 进行配置4. 用virtual media 将我本地笔记本或者pc的光驱虚拟出去,然后在我本地的光驱中,放windows/linux等的安装盘5. 远端的被管理服务器认为自己插了一个usb 光驱,或者软驱,然后按照大家熟悉的正常方式从光盘软盘启动,不过却是用的我本地的盘.6. 你在virtual console 里面进行和平时一样的安装操作.有一点要注意,默认的服务器买来,iLO 是不支持图形界面的,也就是说,当你virtual console 里面的远程服务器开始进入windows或X-windows的时候,你本地pc笔记本的IE 就看不出远端的画面了,需要向hp购买iLO advanced pack,一个iLO serial number,把这个iLO serial number输入到iLO的一个专门输入注册号的地方,就可以突破这个限制了,不过远端如果是linux并且是字符界面,就无所谓买不买了. 这个输入注册号的地方,在你IE访问iLO 后出现的管理界面的菜单上有的,最后一个.就这些,HP的iLO目前是x86服务器系统中最理想的技术了,我们比较了好几种同类产品,在标配不加卡的情况下,HP 的管理应该是最好的.服务器集成 iLO 端口的配置iLO 全名是 Integrated Lights-out,它是惠普某些型号的服务器上集成的远程管理端口,它能够允许用户基于不同的操作系统从远端管理服务器,实现了虚拟存在和控制,从而进行智能型基础构架和管理.开机自检时,按F8键进入 iLO 的设置界面:1. 进入 iLO 的设置:在 File 下的“Set Defaults”是将所有的设置恢复为出厂值。
HP iLO使用指南
</>hpiLO->
</>hpiLO-> show -l all /map1/firmware1
status=0
status_tag=COMMAND COMPLETED
/map1/firmware1
Targets
Properties
version=1.82
date=03/31/2010
HP系列iLO的特点有:
1. 不支持串口,命令行操作不方便。这点比Sun差不少,Sun设备每款SP都支持串口。
2. WEB管理比较丰富,从IE升级Firmware很方便,对WEB客户端IE比较依赖。
3. 支持Web Console以及程虚拟光驱软驱。这些功能有当然好,但不是必需的。
4. iLO的串口与物理机器串口混用,对外屏蔽了不少iLO技术细节。
iLO缺省终端设置是9600,8,n,1,-)
建议使用iLO终端设置是115200,8,n,1,-)
原因是iLO卡引导时候使用了115200的波特率
iLO上相关的逸出键(escape key,两个相邻逸出键最大间隔为1秒)的含义
ESC ( invokes the serial CLI connection.
status=0
status_tag=COMMAND COMPLETED
Resetting iLO.
CLI session stopped
</>hpiLO-> reset /system1
status=0
status_tag=COMMAND COMPLETED
Resetting server.
Hp服务器配置ilo方法
Hp服务器配置ilo方法本文档涉及附件:附件1: HP服务器配置iLO方法图示附件2: 使用iLO远程管理HP服务器的常见问题解答附件3: HP服务器iLO配置检查清单附件4: iLO常用命令参考手册附件5: 相关法律文件及注释1. HP服务器配置iLO方法1.1 iLO(Integrated Lights-Out)简介iLO是一种基于硬件的远程管理技术,允许您远程管理和监控HP服务器。
它为服务器提供了一种独立的管理通道,可以在服务器关机甚至操作系统故障的情况下进行管理。
1.1.1 iLO的主要功能包括:- 远程服务器开机与关机- 监控服务器硬件状态- 远程安装操作系统- 远程控制台访问- 通知和警报功能等1.2 iLO配置前的准备工作在配置iLO之前,需要确保以下准备工作已经完成:1.2.1 获取iLO访问地址和初始用户名密码- 前往HP服务器网络管理端口找到iLO的IP地址或者域名。
- 获取初始的iLO用户名和密码。
1.2.2 确定网络环境- 确保服务器所处的网络环境正常工作,可以从管理节点访问HP服务器。
- 确保服务器与管理节点之间的网络连接正常。
1.3 配置iLO步骤下面是配置HP服务器iLO的详细步骤:1.3.1 进入iLO配置界面- 打开Web浏览器,输入iLO的IP地址或域名。
- 输入初始的iLO用户名和密码,登录到iLO配置界面。
1.3.2 iLO网络设置- 在iLO配置界面中,找到网络设置菜单。
- 根据实际需求,配置iLO所需的网络设置,如IP地址、子网掩码、网关等。
1.3.3 安全设置- 在iLO配置界面中,找到安全设置菜单。
- 配置iLO的安全设置,包括访问权限、SSL证书、SNMP设置等。
1.3.4 服务器电源控制- 在iLO配置界面中,找到电源控制菜单。
- 配置服务器的电源控制方式,如电源开启延迟、电源故障恢复等。
1.3.5 配置远程访问- 在iLO配置界面中,找到远程访问菜单。
Hp服务器配置ilo方法
Hp服务器配置ilo方法HP服务器配置iLO方法1、确认服务器和iLO需求1.1 检查服务器型号和操作系统版本1.2 确认服务器上是否已安装iLO卡1.3 确认当前iLO卡的固件版本2、连接到服务器的iLO接口2.1 打开支持iLO的浏览器2.2 在地质栏中输入服务器的iLO IP地质2.3 输入用户名和密码登录iLO界面3、配置网络设置3.1 “Network”选项卡3.2 在“Network”页面中配置IPv4和IPv6网络设置 3.3 设置主机名和域名3.4 配置DNS服务器设置3.5 保存并应用更改4、配置用户和安全设置4.1 “Administration”选项卡4.2 在“User Administration”页面上,添加、修改或删除用户4.3 配置用户权限和访问控制4.4 “Security”选项卡,配置安全设置4.5 保存并应用更改5、配置远程控制和虚拟媒体功能5.1 “Remote Console”选项卡5.2 在“Remote Console”页面中配置远程控制设置5.3 “Virtual Media”选项卡,配置虚拟媒体设置5.4 保存并应用更改6、配置报警和事件通知6.1 “Administration”选项卡6.2 在“SNMP Settings”页面中配置SNMP设置6.3 在“Eml Settings”页面中配置电子邮件通知设置6.4 保存并应用更改7、配置日志和诊断7.1 “Administration”选项卡7.2 在“Logs”页面中查看和管理日志7.3 在“Diagnostics”页面中运行系统诊断7.4 根据需要保存日志和诊断结果8、更新 iLO 固件8.1 在“Administration”选项卡下,“Firmware Update”子选项8.2 选择适当的固件版本并固件文件8.3 等待固件更新完成并重新启动服务器9、附件- 本文档不需要涉及附件。
10、法律名词及注释- iLO:Integrated Lights-Out,一种HP服务器管理技术,允许远程管理服务器。
Hp服务器配置ilo方法
Hp服务器配置ilo方法标题:HP服务器配置ILO方法HP服务器是许多企业和组织的重要IT基础设施,而ILO(Integrated Lights-Out)则是HP服务器上的一种远程管理技术。
通过配置ILO,用户可以实现对服务器的远程管理、监控和维护,提高管理效率并降低成本。
本文将介绍HP服务器配置ILO的方法。
一、了解ILOILO是HP服务器上的一种远程管理技术,它提供了一种简单、高效的方式来监控和控制远程服务器。
ILO通过将服务器的键盘、鼠标和显示器集成到一起,使得用户可以在远程对服务器进行操作和管理。
ILO还提供了告警通知、电源管理、虚拟媒体等功能,使得用户可以更加方便地管理服务器。
二、配置ILO1、硬件配置要配置ILO,首先需要确保服务器上已经安装了支持ILO的网卡和显示卡。
对于HP服务器,通常需要使用HP指定的网卡和显示卡。
还需要确保服务器的BIOS已经更新到最新版本,以保证支持ILO功能。
2、软件配置在软件方面,需要安装HP的ILO软件和Web浏览器。
HP提供了一个名为“HP iLO”的软件包,其中包括了ILO的驱动程序和Web界面。
安装完成后,可以通过浏览器访问ILO界面,对服务器进行远程管理。
3、配置步骤(1)登录到ILO界面在浏览器中输入服务器的IP,即可登录到ILO界面。
默认情况下,ILO使用HTTP协议,使用默认端口80进行通信。
如果需要使用HTTPS 协议进行加密通信,可以在“HTTPS”选项卡中进行设置。
(2)设置用户名和密码在ILO界面中,可以设置用户名和密码来保护远程访问的安全性。
在“System”选项卡中,找到“Login Information”选项,输入用户名和密码即可。
建议设置一个强密码,并定期更换密码以保证安全性。
(3)配置远程管理选项在“Advanced”选项卡中,可以配置远程管理选项,包括远程重启、关机、监控等功能。
可以根据需要进行设置,例如设置定时重启、自动监控等。
HP服务器ilo配置
HP服务器ilo配置本文档旨在提供有关HP服务器iLO配置的详细步骤和说明。
请按照以下章节逐步操作。
⒈准备工作:⑴确保您有足够的权限访问HP服务器iLO管理界面。
⑵确保您拥有服务器的IP地址和访问凭据。
⒉连接服务器:⑴在Web浏览器中输入服务器的IP地址,并按下Enter键。
⑵输入登录凭据来访问iLO管理界面。
⒊更新服务器固件:⑴在iLO管理界面中,找到“Firmware”或“固件”选项。
⑵单击“Firmware Update”或“固件更新”。
⑶根据提示选择服务器固件文件,并开始更新固件。
⒋配置网络设置:⑴在iLO管理界面中,找到“Network”或“网络”选项。
⑵单击“Network Settings”或“网络设置”。
⑶根据需求配置服务器的IP地址、子网掩码、默认网关等网络设置。
⒌配置访问控制:⑴在iLO管理界面中,找到“Administration”或“管理”选项。
⑵单击“Access Settings”或“访问设置”。
⑶根据需求设置访问控制,例如设置密码策略、启用或禁用特定用户的访问。
⒍配置电源管理:⑴在iLO管理界面中,找到“Power Management”或“电源管理”选项。
⑵根据需求配置电源管理设置,例如电源调度、重启策略等。
⒎配置事件通知:⑴在iLO管理界面中,找到“Event Notification”或“事件通知”选项。
⑵根据需求配置事件通知方式和目标,例如通过电子邮件或SNMP发送通知。
⒏配置安全设置:⑴在iLO管理界面中,找到“Security”或“安全”选项。
⑵根据需求配置安全设置,例如启用或禁用SSL、设置登录超时等。
⒐配置日志功能:⑴在iLO管理界面中,找到“Logs”或“日志”选项。
⑵设置日志功能,例如启用或禁用日志、配置日志级别等。
附件:本文档无涉及附件。
法律名词及注释:⒈ iLO:Integrated Lights-Out,惠普公司生产的远程服务器管理器,使用基于Web界面的服务处理器来监控和管理HP服务器。
HP服务器ilo配置
引言概述:正文内容:一、网络设置1. IP地址设置:管理员可以通过iLO的Web界面或通过服务器的本地控制台来设置iLO的IP地址。
在网络设置页面中,管理员可以设置iLO的IP地址、子网掩码、网关和DNS等参数。
2. DHCP设置:如果希望iLO自动从网络中获取IP地址,管理员可以在网络设置页面启用DHCP功能,并确保服务器所连接的网络有可用的DHCP服务器。
3. SSL/TLS设置:为了保护数据传输的安全性,管理员可以在网络设置页面中启用SSL/TLS功能,配置证书和加密算法等参数。
二、用户管理1. 管理员帐户设置:管理员可以在iLO的用户管理页面创建和管理iLO的管理员帐户。
在创建管理员帐户时,需要设置帐户名称、密码和权限等参数。
管理员帐户具有最高的权限,可以对服务器进行全面的管理和监控。
2. 用户帐户设置:除了管理员帐户外,管理员还可以创建其他用户帐户,以授予不同的权限给不同的用户。
在用户管理页面中,管理员可以创建用户帐户、设置用户名和密码,并指定用户的权限。
3. 目录服务集成:如果服务器管理员正在使用目录服务(如Microsoft Active Directory),可以在用户管理页面中配置iLO 与目录服务的集成,实现统一的身份认证和授权管理。
三、日志记录1. 日志记录设置:iLO提供了详细的日志记录功能,管理员可以在日志记录页面中设置日志的类型和级别,并控制日志的滚动和自动清除等行为。
2. 查看日志:管理员可以通过iLO的Web界面或通过命令行界面来查看和分析服务器的日志记录。
通过查看日志,管理员可以及时发现并诊断服务器的故障和问题。
四、事件通知1. 事件设置:iLO可以根据服务器的状态和事件生成相应的通知消息,管理员可以在事件页面中设置哪些事件触发通知,并指定通知的方式(如电子邮件、SNMP等)。
2. 通知管理:在通知管理页面中,管理员可以查看、配置和测试通知的设置。
管理员还可以查看通知的历史记录,以便追踪和分析服务器的事件发生情况。
HP服务器集成iLO端口的配置和应用
服务器集成iLO端口的配置和应用开机自检时,按F8键进入iLO的设置界面:1.进入iLO的设置:这项是将所有的设置恢复为出厂值。
2.配置网络:分别设置IP 地址和DNS。
IP应在同一个网段中,注意子网掩码的一致。
(只有在DHCP被设为Disable时,才能设置IP address/Subnet Mask/Gateway IP address)DNS的名字在服务器前面带的卡片上,还包括管理员的账号和密码。
IP必须是静态的,所以DHCP需设置为OFF。
3.在这里可以添加、删除、更改远程访问User的密码,权限等。
Add userRemoveEdit4.Settings 的选项设置Keyboard的属性等,一般都为默认值。
5.About中为iLO的firmware version等一些信息。
iLO使用的方法:由于集成的iLO是一个简板的设备,很多的功能不能实现,需要另行购买选件号是263825-B21的产品,叫做Integrated Lights-Out Advanced Pack.在客户端使用IE浏览器在地址栏输入设定的IP地址,在前面要加Https:// 即可登陆需要管理的服务器。
需要注意的:IE必须5.5以上,密码校验128-bit.输入设定的user和Password登录。
1.System StatusStatus Summary在System Status这一页的菜单如下:对应的界面如下:iLO Status:iLO的状况Server Status:服务器的状态iLO Event Log:iLO的日志Integrated Management Log:Server and iLO Diagnostics:2.Remote Console这页的菜单如下:Remote Console和Remote Console(dual cursor)可以远程控制服务器,但是在集成的iLO上只能看到字符界面,不能看到图形界面(需要加选件)。
ilog配置
1.Ilo的配置重新配置Ilo前请务必备份Ilo license key开机自检到lights-out 2(Gen8为Ilo4)时按F8(如果无法确认时机,开机自检后多次按F8即能进入Ilo配置界面)选择DNS/DHCP。
选择Network-DHCP,将DHCP Enable改为OFF如果网络中有DHCP服务并且想使用DHCP请不要关闭此选项,并且无需手动设置下方的IP。
选择NIC and TCP/IP,配置ip地址,用于网页登陆。
设置IP地址,网关及子网掩码。
(spare键用于切换,F10用于保存)添加新的用户名及密码,F10保存。
在主流浏览器上输入刚刚配好的IP地址,进入Ilo登录界面,输入用户名、密码登录管理界面。
登录到管理界面可以通过左侧选项对机器硬件进行监控。
若想远程操纵服务器,需要输入license key,并在Remote Console选项进行登录。
2.Ilo配置界面的基本设置恢复出厂设置(设置此项目后,机器会自动重启并且Ilo的相关用户名,密码,IP 地址,Ilo license都会被清空,所以在set defaults前请务必备份相关信息)用户的删除及编辑。
dedicated网口设置。
Network Interface Adapter有三个选项,分别为shared network port-low,on,off。
对于拥有Dedicated Ilo port功能的机器默认选项为shared,要想使用添加的Ilo management port module,需要手动改为on。
其他设置①此设置可以启用到Ilo4的连接。
如果被禁用,将阻止所有到Ilo4的链接。
默认开启状态。
②此设置可以启用或禁用基于Ilo ROM的设置实用程序。
通常,Ilo4选件ROM会提示您按F8进入RBSU,但是如果Ilo4或Ilo4 RBSU已禁用,则将绕过RBSU提示。
默认开启状态。
③通过此设置,可以在提供或不提供用户信用凭证的情况下进行RBSU 访问。
HP服务器集成iLO端口的配置
服务器集成iLO端口的配置iLO全名是Integrated Lights-out ,它是惠普某些型号的服务器上集成的远程管理端口,它能够允许用户基于不同的操作系统从远端管理服务器,实现了虚拟存在和控制,从而进行智能型基础构架和管理开机自检时,按F8键进入iLO的设置界面:10Z4 HE DetectedCOMPAQ Syfitaik BIOS - P2? (0?/30/Z002>Capyright 193Z 2002 Compaq Computer Corporacti on. Al 1 rights reserved..Processor 1 Initialised 岂t 1.4 GHz <286 KE KB L31Advanced Ketaory Prot-ecticn Mode: Advanced BCC SupportRedundwt KOH Dstscted - This rant al ns & valid backup systeui ROH.Campaq Int egratsd Lights-Out press (F8 ] tu coni igrire1.进入iLO的设置:在File下的“ Set Defaults是将所有的设置恢复为出厂值。
FileCbmpaq Integrrsted Lights一Otit IJetiifOjrk Use r Settings AbouttRestore i LO to f stctoiry de £axi丄匕吕.Online2.配置网络:分别设置IP地址和DNS o IP应在同一个网段中,注意子网掩码的一致。
(只有在 DHCP被设为Disable 时,才能设置 IP address/Subnet Mask/Gateway IP address)3.在这里可以添加、删除、更改远程访问 User 的密码,权限等。
0口 一沖一 M —bQ —dS —" ON 12@,S3,31.114255,255,255.0128.88,31. i DNS 的名字在服务器前面带的卡片上,还包括管理员的账号和密码 Compaq intregrated Lights-Out FiIe (Jet-TjorhlUser Settin.gs About Mstwork Conf 1 gpirationMAC AddressNefwo rk Inter f aca Ad apK er Trfizisceiver SpeedAutoselectIP Address Subnet Mask Gateway IP Address[F10j=SavsHit [SPACE1 to change t-his setting.]OnlineCompaq Integrated Lights-Out7110 ffet-tjorklUser Settings About Hit [ SPACE ] to change 七his setting,[onlineIP 必须是静态的,所以 DHCP 需设置为OFFNet wo rk Au ■& □ c on 11 gur at i onAdd user Remove3.在这里可以添加、删除、更改远程访问User的密码,权限等。
Hp服务器配置ilo方法
Hp服务器配置ilo方法HP服务器配置iLO方法1.概述iLO(Integrated Lights-Out)是惠普(HP)服务器的远程管理功能。
通过iLO,管理员可以在远程处于服务器关闭状态时进行服务器的管理和控制。
本文档详细介绍了如何配置HP服务器的iLO 功能。
2.确认服务器型号和iLO版本在开始配置iLO之前,请先确认服务器型号和iLO版本。
这些信息通常可以在服务器的外壳或启动界面上找到。
3.连接iLO端口3.1 检查服务器背板,找到iLO端口。
通常,iLO端口是一个独立的以太网端口。
3.2 将一根网线连接到iLO端口。
4.配置iLO网络设置4.1 在本地计算机上打开网页浏览器。
4.2 输入服务器的iLO IP地质(通常是192.16①)。
4.3 输入管理员账户名和密码进行登录。
4.4 在iLO管理界面中,找到网络设置选项,并进行配置。
这包括设置iLO的IP地质、子网掩码、网关和DNS服务器等。
5.配置iLO高级设置5.1 在iLO管理界面中,找到高级设置选项。
5.2 配置iLO的高级功能,如SSL证书、SNMP、LDAP和Active Directory集成等。
6.配置远程访问权限6.1 在iLO管理界面中,找到用户管理选项。
6.2 创建或编辑用户,并设置其权限。
可以根据需要配置用户的访问级别和权限。
7.完成iLO配置完成上述配置后,将保存更改并退出iLO管理界面。
8.安全防护措施为了确保iLO的安全性,建议采取以下措施:●定期更改iLO管理员密码。
●禁用不必要的服务和功能。
●启用iLO的防火墙功能。
●及时升级iLO固件以获取最新的安全补丁。
9.附件本文档没有附件。
10.法律名词及注释●iLO:Integrated Lights-Out,是惠普公司开发的远程管理功能。
●IP地质:Internet Protocol Address,用于标识设备在网络中的唯一地质。
●子网掩码:Subnet Mask,用于划分子网的掩码。
HPILO远程管理口及帐号密码设置
HPILO远程管理口及帐号密码设置1.HP ILO远程管理口设置1.1.服务器通电开机自检后,当屏幕出现“Intergrated Light-Out 2 AdvancedPress [F8] to Configure”(ilo4提示为:iLO4 Advanced press [F8] toconfigure)提示的时候按“F8”,进入iLO的高级设置。
(图1.1.1 ILO远程管理口设置图1)1.2.如在开机时未发现F8提示,可在自检界面出现”Press any key to viewOption ROM messages”时直接按“F8”进入到ILO的设置界面。
(图1.1.2 ILO远程管理口设置图2)1.3.部分ILO默认情况下是设置为通过DHCP获取IP地址,故设置静态IP前需关闭ILO的DHCP功能。
在“Network”菜单中选择“DNS/DHCP”,使用空格键将DHCP Enable状态改为“OFF”,然后按“F10”保存。
(图1.1.3 ILO远程管理口设置图1)(图1.1.3 ILO远程管理口设置图2)1.4.关闭DHCP功能后选择“Network”菜单中的“NIC and TCP/IP”,进入网络配置界面,设置ILO接口的IP地址、子网掩码和网关。
设置完毕按“F10”保存。
(如果未关闭ILO的DHCP功能此处是无法配置的)(图1.1.4 ILO远程管理口设置图1)(图1.1.4 ILO远程管理口设置图2)1.5.添加或者修改用户名及密码,按“F10”保存。
(图1.1.5 ILO远程管理口设置图1)(图1.1.5 ILO远程管理口设置图2)2.HP只读账户的添加2.1.iLO创建远程管理模块帐号和密码:打开iLO,选择“Administration” ——“User Administration” ——新建选择“New”;(图1.2.1 ILO配置只读权限用户图1)(图1.2.1 ILO配置只读权限用户图2)(图1.2.1 ILO配置只读权限用户图3)3.HP iLO配置超时设置1.1.1打开iLO,选择“Administration” ——“Ac cess Settings” ,在“idle connection timeout (minutes)” 处设置为“infinite” 则永不超时。
HP服务器远程管理软件iLO使用介绍
HP服务器远程管理软件iLO使用介绍iLO 是一组芯片,内部是vxworks的嵌入操作系统,在服务器的背后有一个标准RJ45口对外连接生产用交换机或者带外管理的交换机. iLO自己有处理器,存储和网卡,默认网卡配置是DHCP,可以在服务器启动的时候进入iLO 的ROM based configuration utility 修改. 服务器的面板左侧,会有一个白色的纸吊牌,上面写着iLO 网卡上的DNS name和Password. 请勿随便更改,更改了不要遗失. iLO的使用很简单. 用网线把iLO口和你的LAN switch或者专门的OB switch 相连. 如果你准备让iLO 默认方式工作,你需要有一个LAN内的DHCP和DNS 服务器存在. 如果你在服务器启动的时候修改dhcp 到static ip,就无所谓了. 在你的笔记本或者pc上,开一个IE(支持java),然后地址那里书写 iLO DNS name(写在纸吊牌上的,你需要DHCP DNS 服务器在局域网内). 就可以看到iLO 界面了. 或者直接填写iLO的ip地址也可以.iLO界面除了报告一些硬件信息之外,主要提供了三大类控制:第一类是Virtual console,就是类似pc anywhere 的远程控制了,但是和软件的控制不一样,它是完全硬件级的,哪怕你的服务器没有操作系统,或者硬盘损坏,或者重新启动,都可以完整的进行控制,所以除非更换被管理服务器的硬件,正常的操作都可以用iLO来做,根本不用进入机房.(当然得保证网络通畅).第二类是 Virtual power,虚拟电源,模拟所有的电源开关动作,比如按住不放,按住就放等等...第三类是Virtual media,虚拟介质,你可以将pc或者笔记本上的光驱软驱,通过LAN虚拟给被管理的服务器。
这个主要是用来安装操作系统,或者传输数据,打补丁之类的。
比如那个被管理服务器是新的,没有操作系统,硬盘也没有作阵列,我怎么结合上面的三类控制手段来操作呢?1. 用virtual power重启动服务器2. 用virtual console 远程操作服务器,在服务器启动的POST时候,进入服务器的Smart array 6i Rom based utility 进行阵列配置3. 用virtual console 远程操作服务器,在服务器POST完毕的结束阶段,F9进入系统的BIOS,我们行话叫RBSU 进行配置4. 用virtual media 将我本地笔记本或者pc的光驱虚拟出去,然后在我本地的光驱中,放windows/linux等的安装盘5. 远端的被管理服务器认为自己插了一个usb 光驱,或者软驱,然后按照大家熟悉的正常方式从光盘软盘启动,不过却是用的我本地的盘.6. 你在virtual console 里面进行和平时一样的安装操作.有一点要注意,默认的服务器买来,iLO 是不支持图形界面的,也就是说,当你virtual console 里面的远程服务器开始进入windows或X-windows的时候,你本地pc笔记本的IE 就看不出远端的画面了,需要向hp购买iLO advanced pack,一个iLO serial number,把这个iLO serial number输入到iLO的一个专门输入注册号的地方,就可以突破这个限制了,不过远端如果是linux并且是字符界面,就无所谓买不买了. 这个输入注册号的地方,在你IE访问iLO 后出现的管理界面的菜单上有的,最后一个.就这些,HP的iLO目前是x86服务器系统中最理想的技术了,我们比较了好几种同类产品,在标配不加卡的情况下,HP 的管理应该是最好的.服务器集成 iLO 端口的配置iLO 全名是 Integrated Lights-out,它是惠普某些型号的服务器上集成的远程管理端口,它能够允许用户基于不同的操作系统从远端管理服务器,实现了虚拟存在和控制,从而进行智能型基础构架和管理.开机自检时,按F8键进入 iLO 的设置界面:1.进入 iLO 的设置:在 File 下的“Set Defaults”是将所有的设置恢复为出厂值。
HP iLO Management Engine设置
HP iLO Management EngineHP iLO Management Engine简介 (1)1、HP iLO基本功能及配置 (2)1.1 HP iLO 具有的功能 (2)1.2 HP ILO的基本配置及使用界面 (2)2、Active Health System (10)2.1HP Active Health System 功能 (10)2.2HP Active Health System log收集 (10)3、HP Agentless Management (13)4、Intelligent Provisioning (14)4.1Intelligent Provisioning的功能 (14)4.2配置Intelligent Provisioning Preferences (15)5、HP Insight Remote Support 7.0 (18)5.1HP Insight Remote Support 7.0功能 (19)5.2HP Insight Remote Support 7.0配置 (19)6、Iphone手机远程登陆管理HP ILO (21)7、不同ILO比较 (26)HP iLO Management Engine简介HP iLO Management Engine 是一组嵌入式管理功能,支持服务器从初始部署直到后续管理的整个生命周期。
1、HP iLO基本功能及配置HP iLO 子系统是某些HP ProLiant 服务器的标准组件,它可简化初始服务器设置、服务器运行状况监视、电源和散热优化以及远程服务器管理。
HP iLO 子系统包括智能微处理器、安全内存和专用网络接口。
这种设计使HP iLO 能够独立于主机服务器及其操作系统。
HP iLO 启用和管理Active Health System,并还具有Agentless Management。
所有关键的内部子系统均由HP iLO 监视。
HP ILO配置手册
iLO是Intergrated Light-Out的缩写,是惠普特有的远程管理功能,目前最新的版本是iLO2。
通过iLO2可以实现硬件级别的服务器远程管理,包括开关机、重启、服务器状态的监控、虚拟KVM等。
目前在惠普3、5、7系列服务器以及刀片服务器上一般都集成了iLO2控制芯片,管理员可以通过Web方式远程进行管理,配置过程和管理过程都非常简便,管理员可以从环境恶劣的机房中解放出来,管理过程轻松简洁,也降低了企业TCO成本。
主板上集成的iLO2控制芯片一、iLO2的配置iLO2的配置过程非常简便,分为服务器端和客户端的配置。
首先我们需要为服务器的iLO2端口设置一个IP地址,可以手动设置或者通过DHCP服务器分配。
通过DHCP获取IP地址的方法很简单,只需通过网线将服务器后端的iLO2接口和DHCP服务器连通即可。
惠普服务器后端的iLO2接口为iLO2接口设置静态IP我们需要以下的步骤:1、服务器加电后,当屏幕出现“Intergrated Light-Out 2 Advanced Press [F8] to?Con figure”提示的时候按F8键,进入iLO2的高级设置。
iLO2配置界面因为iLO2默认情况下是设置为通过DHCP获取IP地址,所以如果我们要设置静态IP的话首先要关闭iLO2的DHCP功能。
在“Network”菜单中选择“DNS/DHCP”,使用空格键将DHCP Enable状态改为“OFF”,然后按F10键保存。
关闭DHCP功能关闭DHCP功能之后选择“Network”菜单中的“NIC and TCP/IP”,进入网络配置界面,在这里我们可以设置iLO2接口的IP地址、子网掩码和网关。
设置完毕后还是按F10来保存,需要注意的是如果不在开始关闭iLO2的DHCP功能这里是不能设置的。
在这里我们将IP地址设置为。
设置IP地址在“Setting”菜单中可以进行一些其他的iLO2设置,这些设置保持默认配置即可。
惠普HP-ILO配置3
通过iLO安装系统――――――――――个人总结以下文章以iLO1为基准,如果是iLO2。
界面可能会不同。
但操作顺序是一样的。
原理:就是通过iLO端口。
远程把台式机的光软驱虚拟到服务器端,这样就相当于服务器也有了光驱和软驱了。
这样就可以象平时一样来安装系统了。
一、首先您要到服务器旁边。
连接一个电源线、显示器、键盘,网线要接在iLO的端口上,网线的另一端接在交换机上。
开服务器,当看到有iLO字样时会有F8的提示。
按一下F8。
在iLO的配置中设定用户名,密码。
IP地址等网络设置,这些参数要和台式机配在同一个网段中。
台式机也要接在同一个交换机上。
要重启服务器,再到pc端ping一下看看网络是否通了。
配置iLO参考《F8配置ilo》的图片。
二、回到台式机旁边,打开IE浏览器。
对浏览器要求是6.0以上。
把IE安全特性降低,要求安装JA V A虚拟机。
JA V A虚拟机可以到网上找。
三、在ie中输入服务器iLO的IP地址,输入用户名和密码。
1、先输入iLO的试用版license key:32Q8W-GKHTR-NPDKY-5CD79-T525H见下图2、之后要做的就是虚拟光驱了。
参看《ilo中虚拟光软驱》。
成功之后,把系统光盘或者SmartStart CD放入光驱里。
在Virtual Devices中用虚拟的电源管理界面(见下图)打开服务器的电源或重新启动服务器。
在Remote console 里选择Integrated remote console就会看到服务器的启动画面。
这样在台式机上就会看到服务器的启动信息。
现在就可以象平时一样来安装系统了。
启动服务器看到的画面注意事项:1、请先备份数据;2、以上是个人总结,不代表任何组织。
仅供参考。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
iLO是Intergrated Light-Out的缩写,是惠普特有的远程管理功能,目前最新的版本是iLO2。
通过iLO2可以实现硬件级别的服务器远程管理,包括开关机、重启、服务器状态的监控、虚拟KVM等。
目前在惠普3、5、7系列服务器以及刀片服务器上一般都集成了iLO2控制芯片,管理员可以通过Web方式远程进行管理,配置过程和管理过程都非常简便,管理员可以从环境恶劣的机房中解放出来,管理过程轻松简洁,也降低了企业TCO成本。
主板上集成的iLO2控制芯片
一、iLO2的配置
iLO2的配置过程非常简便,分为服务器端和客户端的配置。
首先我们需要为服务器的iLO2端口设置一个IP地址,可以手动设置或者通过DHCP服务器分配。
通过DHCP获取IP地址的方法很简单,只需通过网线将服务器后端的iLO2接口和DHCP服务器连通即可。
惠普服务器后端的iLO2接口
为iLO2接口设置静态IP我们需要以下的步骤:
1、服务器加电后,当屏幕出现“Intergrated Light-Out 2 Advanced Press [F8] to Configure”提示的时候按F8键,进入iLO2的高级设置。
iLO2配置界面
因为iLO2默认情况下是设置为通过DHCP获取IP地址,所以如果我们要设置静态IP的话首先要关闭iLO2的DHCP功能。
在“Network”菜单中选择“DNS/DHCP”,使用空格键将DHCP Enable状态改为“OFF”,然后按F10键保存。
关闭DHCP功能
关闭DHCP功能之后选择“Network”菜单中的“NIC and TCP/IP”,进入网络配置界面,在这里我们可以设置iLO2接口的IP地址、子网掩码和网关。
设置完毕后还是按F10来保存,需要注意的是如果不在开始关闭iLO2的DHCP功能这里是不能设置的。
在这里我们将IP地址设置为192.168.1.2/24。
设置IP地址
在“Setting”菜单中可以进行一些其他的iLO2设置,这些设置保持默认配置即可。
至此服务器端的配置就完成了,设置非常简单。
通过iLO2的配置界面我们还可以进行添加管理帐户、恢复出厂配置等操作。
可以添加管理帐户
当客户端通过Web方式连接到iLO2端口时,需要输入管理帐户的用户名和密码,默认情况下用户名为“Administrator”,密码在服务器顶盖的标签上也会提供,注意大小写是敏感的。
在配置界面的“User”菜单中我们还可以添加删除管理帐户。