开关电源测试报告
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Pass / Fail: According to specification 4 hours storage at 0℃, and operating at 40℃
. : Not Specified Test Equipment: TOPNOTCH OTC-2B-N Open Chamber
. : Not Tested CHROMA Series AC Source / DC Load
A. INPUT CHARACTERIZATION
INPUT CURRENT/POWER/EFFICIENCY/POWER FACTOR
Test conditions:
The unit is set at maximum load and the input voltage is varied from the minimum to the
maximum value. Efficiency is computed and Power Factor is either computed or measured after
10 minutes warm up at least.
Test equipment:
Chroma Model 8000 Power Supply Auto Test System
Chroma Model # 6590 9KVA Low Impedance AC Source
Chroma Model # 630X0 DC Load
Chroma Model # 6630 Power Analyzer
Pass/Fail criteria:
The unit test shall meet the specification requirements.
Test result: PASS
@25C
Vin(Vac)Freq(Hz)Iin(A)Pin(W)Vout(V)Pout(W)Pd(W)PF Eff(%) Vin(Vac)Freq(Hz)Iin(A)Pin(W)Vout(V)Pout(W)Pd(W)PF Eff(%)
@40C
Vin(Vac)Freq(Hz)Iin(A)Pin(W)Vout(V)Pout(W)Pd(W)PF Eff(%)
ACTIVE MODE EFFICIENCY & NO LOAD INPUT POWER
Test conditions:
The unit is set at no load and the rated input voltage for at least 15 minutes.
The ambient temperature is set between 15 Deg C to 35 Deg C
Test equipment:
Chroma Model 8000 Power Supply Auto Test System
Chroma Model # 65909KVA Low Impedance AC Source
Chroma Model # 630X0 DC Load
Chroma Model # 6630 Power Analyzer
Pass/Fail criteria:
The unit test shall meet the specification requirements.
ACOUSTIC NOISE
Test conditions:
Measurements to determine the AC adapter sound pressure are made using a 1/2” low noise free-field microphone in a inner size with 45(W)×45(D)×65(H) cm^3 Anechoic chamber. Test equipment:
Anechoic Chamber: Free-Field Acoustics Corp. Lower than 10dB(A) background noise.
B & K Portable Pulse – Type 3560C, Microphone: 4190, Preamplifier: 2669L
Pass/Fail criteria:
The AC Adapter shall produce no human perceivable audible noise (less then 25dB).
The above diagram depicts the microphone of the frontal plane of the microphone to the
Adapter and the height of the centerline of the microphone to the Adapter.
Acoustic Noise Test Set-Up
INRUSH CURRENT
Test condition:
For cold start test at room ambient, the adapter should be off for at least one hour at the test temperature to ensure it is at a uniform temperature before the test is started. Turn on the
UUT
at 90 degrees at positive cycle or 270 degrees at negative cycle. Between each test, the UUT
shall be cooled down for at least 3 minutes and the Bulk Cap’s Energy is discharged.
For hot start test at max. Operating ambient, the adapter should be on and running for at least one hour at the test temperature to ensure it is at a uniform temperature before the test is
Repetitive ON/OFF (1Sec. ON/1Sec. OFF for 10 times) cycling of the UUT and turn on at 90
degrees at positive cycle or 270 degrees at negative cycle. Between each test, the Bulk Cap’s
Energy shall be discharged.
Test equipment:
Chroma Model 8000 Power Supply Auto Test System
Chroma Model # 6590 9KVA Low Impedance AC Source
Chroma Model # 630X0 DC Load
Tektronix AM503 Current Probe Amplifier
Tektronix A6303 Current Probe
Tektronix TDS-5054 Oscilloscope
Pass/Fail criteria:
The inrush current shall meet the specification requirements.
AC line inrush current shall not damage any components, nor cause the AC line fuse to blow,
under any DC load conditions, any ambient temperature, and with any ac line input voltage
and frequency.
Test result: PASS
Extended Name = Cold start 25 deg. ambient; after Extended Name = Cold start 25 deg. ambient; after