先计算出电流单相:电流I=负载功率(W)/(电压(V)X功率因数)=负载功率(W)/(220X0.7)---0.7or0.8 三相:电流I=负载功率(W)/(电压(V)X1.732X功率因数))=负载功率(W)/(380X1.732X0.7)0.7or0.8然后查电工手册,根据导线的安全载流量得到所选择导线的截面积。

备一本电工手册,会方便得很,会查得清清楚楚。

型号BV额定电压(KV)0.45/0.75导体工作温度(°C)70环境温度(°C)303540303540导线排列O-S-O-S-O导线根数2~45~89~1212 以上2~45~89~1212 以上2~45~89~1212 以上标称截面(mm 2)明敷载流量(A)导线穿管敷设载流量(A)1.52322201398712976118762.53129271713111016121091511984413936241815132217141221151311653504631231917292118162020161510746964443328254131262338292421169993866045383457423532523932292513212411583625247775748437053443935161151140103776458967260548866554950201189175127957971117887366108816760702592432251651231039215211495851401058778953162972752071551291161921441201081761321109912037435132524518415313822617014112720815613011715042640037028821618016226519916614924418315213718549546443033525120918830923219317428421317715924059255651539629724722236627522926336252210189注:明敷载流量值系根据S>2De(De-电线外径)计算给个实用口诀你:单相电功率P=电压*电流三相电功率P=1.732*线电压*线电流*功率因数000W = 1.732*380*00A*0.800A=(000W/1.732*380*0.8)/5-2.5=0M2导线截面积与载流量的计算一、一般铜导线载流量导线的安全载流量是根据所允许的线芯最高温度、冷却条件、敷设条件来确定的。

简单实用!电动机对应开关和电线电缆配合表

简单实用!电动机对应开关和电线电缆配合表

简单实用!电动机对应开关和电线电缆配合表
展开全文
我们平时会用到很多很多的电动机,很多人遇到要怎么算就头大,现在我给大家整理一下,具体的搭配就简单了。

说明:1.22kW以上考虑软启动,软启动后启动电流按正常电流的4倍考虑(无软启动时,启动电流按正常电流的7倍考虑)。

即:无软启动时瞬时整定电流:Iqd=1.2×1.8×7×Ie=15.2Ie或Iqd=2.16×I起
有软启动时瞬时整定电流:Iqd=1.2×1.8×4×Ie=8.7Ie
2. VV电缆考虑在空气中敷设,YJV22电缆考虑直埋敷设(土壤热阻系数按2K.m/W考虑),BV线导体工作温度按70度、环境温度按35度(4根导线)考虑。

3. 电缆穿管按1个弯曲考虑。

第一张
第二张
第三张
第四章
第五章
怎么样,简单的很吧,懂了就简单的。

135张电工必备接线图!包含开关、电机、断路器、电热偶、电表接线!

135张电工必备接线图!包含开关、电机、断路器、电热偶、电表接线!

135张电工必备接线图!包含开关、电机、断路器、电热偶、电表接线!这是非常齐全的一篇电工接线图的文章,包含开关接线图断路器、接触器控制回路接线图,电机逆转、正转原理接线图,电表进出接线图,电路开关接线图,电热偶接线图,希望能帮到想学这些专业的朋友,不是专业的也可以看一下懂得这些原理,以免家里电路有问题的时候出现手忙脚乱的现象,但是前提必须在安全的情况下动手去做,毕竟比较危险,电不能开玩笑的。

一、开关接线图一开单控开关接线图二三开连体单控开关接线图四开连体单控开关接线图一开五孔单控插座接线图二开五孔单控插座接线图一开双控开关接线图二三开单控开关接线图四开单控开关接线图一开五孔单控插座接线图二三开双控开关接线图一开多控开关接线图两开多控开关接线图三开多控开关接线图二、断路器、接触器控制回路:三:热电偶:四、电能表:三相四线电度表互感器接线电源线从互感器P1进的接线方式电源线从互感器P2进的接线方式三相四线电度表互感器接线电源线从互感器P1进的接线方式三相三线电度表接互感器电路单相电能表的接线电源从P1进电源线从P2穿过(逆穿)接线图汇总3个单相电度表互感器接线电源线从P1面穿过互感器二次线端接电流表不分彼此五、其他:单相电机顺逆转控制控制顺逆转电葫芦吊机六、电动机:延时七、日光灯类:双联开关的2种双控电路(如图)两种控制方式(如图)桥式全波整流滤波电路(如图)通电延时亮灯(如图)延时断电(如图)延时通断不断循环且达到设置循环数断电(如图)灯延时熄灭(如图)传统镇流器和电子镇流器(如图)延时通断不断循环且达到设置循环数断电(如图)2灯循环点亮(如图)循环流水灯(如图)时间断电器断电延时控制(如图)通电延时断电(如图)通电延时亮灯(如图)桥式全波整流滤波电路(如图)延时通、断循环运行(如图)2灯循环亮、熄(如图)时间继电器断电延时控制(如图)。

电能表接法

电能表接法

电能表接法
需要注意的是,电能表的接线应该符合国家和地方的电气安全规范和标准。在进行接线前 ,应该确保电源和负载的电压、频率和相数等参数与电能表相匹配。同时,接线时应注意正 确连接相线、零线和地线,避免接反或者短路等错误操作。
如果不具备相关电气知识和经验,建议请专业电工进行电能表的接线工作,以确保安全和 正确性。
电能表接法
电能表的接法主要包括电源接线和负载接线两部分。 1. 电源接线:
- 将电源的相线(L)连接到电能表的输入端的相线(L1)上。 - 将电源的零线(N)连接到电能表的输入端的零线(N)上。 - 将电源的地线(PE)连接到电能表的输入端的地线(PE)上。
2. 负载接线: - 将负载的相线(L)连接到电能表的输出端的相线(L2)上。 - 将负载的零线(N)连接到电能表的输出端的零线(N)上。 - 上。

家用入户电源总控制盒接线图

家用入户电源总控制盒接线图

家用入户电源总控制盒接线图
客厅插座卧室插座后三间插座备用电源
(漏保)(漏保)(漏保)(漏保)
16A 20A 20A 25A 20A 25A 16A 20A
说明:1×2.76线1×2.24线1×1.76线
1×1.37线火线零线接地总开关为PVC双极空开空调总开关为PVC双极漏保
在家里装照明用电线路,您可以按这个取材来选用:1,照明线路可以用1x1.37mm(2平方毫米)的铜芯塑料线,每个控制回路的使用功率不要超过2KW(实际上每个控制回路上灯的总功率一般不回超过2KW的);2,家中的
小功率插座(电冰箱、洗衣机、台灯、电视、音响等等)的线路可以采用1x1.76mm(2.5平方毫米)的铜
芯塑料线,并且家中的各个“功能区”,比如像各个房间之间可以两个房间共用一路控制,客厅和餐厅可以
共用一路控制,厨房和卫生间可以共用一路控制;3,各个房间的空调等(还有象卫生间的蒸汽淋浴房等)
使用16A“大插座”的线路,可以使用1x2.24mm(4平方毫米)的铜芯塑料线,并且每个插座为一单独回路
控制。

4,所有线路必须至少要用阻燃的PVC塑料穿线管穿线布设,不允许直接埋入墙内或者是“裸线”(指
不穿管)放置在吊顶上面。

4.3~4.4_开关与BV电线、电缆配合表1

4.3~4.4_开关与BV电线、电缆配合表1

25A 32A 40A 50A 63A 80A 100A 125A 160A
BV-5x10mm² BV-5x10mm² BV-5x16mm² BV-4x25+1x16mm² BV-4x35+1x16mm² BV-4x50+1x25mm² BV-4x70+1x35mm² BV-4x95+1x50mm² BV-4x150+1x95mm²
~380V配电回路-微型断路器(MCB)与BV绝缘电线配合表
BV绝缘电线(0.45/0.75kV,导体工作温度70℃, 环境温度30℃,暗敷在导管内) WDZ-BYJ(F)绝缘电线(0.45/0.75kV,导体工作温 度90℃,环境温度30℃,明敷在空气中)
穿管规格 φ SC15/JDG16 SC15/JDG16 SC15/JDG20 SC20/JDG25 SC20/JDG25 SC25/JDG32 SC25/JDG32 SC32/JDG32 SC40/JDG40 SC40
YJV电力电缆(0.6/1kV,导体工作温度90℃,环境 WDZ-YJ(F)电力电缆(0.6/1kV,导体工作温度90 温度35℃,铜芯,线槽敷设方式) ℃,环境温度35℃,线槽敷设,三芯) YJV-5x4mm² YJV-5x6mm² YJV-5x10mm² YJV-5x16mm² YJV-4x25+1x16mm² YJV-4x25+1x16mm² YJV-4x35+1x16mm² YJV-4x50+1x25mm² YJV-4x70+1x35mm² YJV-4x95+1x50mm² YJV-4x120+1x70mm² YJV-4x150+1x70mm² YJV-4x240+1x120mm² 2(YJV-4x95+1x50mm² ) 2(YJV-4x150+1x70mm² ) 2(YJV-4x185+1x95mm² ) 2(YJV-4x240+1x120mm² ) 3(YJV-4x185+1x95mm² ) 3(YJV-4x240+1x120mm² ) 4(YJV-4x240+1x1+120mm² ) WDZ-YJ(F)-5x4mm² WDZ-YJ(F)-5x6mm² WDZ-YJ(F)-5x10mm² WDZ-YJ(F)-5x16mm² WDZ-YJ(F)-4x25+1x16mm² WDZ-YJ(F)-4x25+1x16mm² WDZ-YJ(F)-4x35+1x16mm² WDZ-YJ(F)-4x50+1x25mm² WDZ-YJ(F)-4x70+1x35mm² WDZ-YJ(F)-4x95+1x50mm² WDZ-YJ(F)-4x120+1x70mm² WDZ-YJ(F)-4x150+1x70mm² WDZ-YJ(F)-4x240+1x120mm² 2(WDZ-YJ(F)-4x95+1x50mm² ) 2(WDZ-YJ(F)-4x150+1x70mm² ) 2(WDZ-YJ(F)-4x185+1x95mm² ) 2(WDZ-YJ(F)-4x240+1x120mm² ) 3(WDZ-YJ(F)-4x185+1x95mm² ) 3(WDZ-YJ(F)-4x240+1x120mm² ) 4(WDZ-YJ(F)-4x240+1x120mm² )

老电工分享25张电能表接线图,你懂多少?快来看看吧!

老电工分享25张电能表接线图,你懂多少?快来看看吧!

老电工分享25张电能表接线图,你懂多少?快来看看吧!
电能表是用来测量电能的仪表,又称电度表,火表,千瓦小时表,指测量各种电学量的仪表。

使用电能表时要注意,在低电压(不超过500伏)和小电流(几十安)的情况下,电能表可直接接入电路进行测量。

在高电压或大电流的情况下,电能表不能直接接入线路,需配合电压互感器或电流互感器使用。

相信大家在家里也见过吧,本期国内最大的电气产品销售与服务平台——电老虎网将整理好的25张常用电能表接线图分享给大家,欢迎转发收藏!
单相有功电度表(简称:单相电度表)由接线端子、电流线圈、电压线圈、计量转盘、计数器构成,只要电流线圈通过电流,同时电压线圈加有电压,转盘就受到电磁力而转动。

单相电度表共有5个接线端子,其中有两个端子在表的内部用连片短接,所以,单相电度表的外接端子只有4个,即1、2、3、4号端子。

由于电度表的型号不同,各类型的表在铅封盖内都有4各端子的接线图。

电线连接一览表

电线连接一览表

ɹɹ ʢ 50ʗ60Hzʣ 16 17 18 19 20
DC 12Vʢ1.8Wʣ DC 24Vʢ1.8Wʣ
21 22 23 24 25 26 ˞1 28 29 30
标准
˞1 1 2 3 4 5
AC100Vʢ1.8ʗ1.4Wʣ
AC200Vʢ1.8ʗ1.4Wʣ 6 7 8 9 10
ɹ ʢ 50ʗ60Hzʣ DC 24Vʢ1.8Wʣ
12345 6 7 8 9 10
直接导线
1 回路图 a
直接导线
24 回路图 b
导线管导线
3 回路图 a
小型端子箱(G1/4)
4 回路图 a
小型端子箱
5 13 回路图 c
注 意 事
选择项目
11 12 13 14 15

DC 12Vʢ0.6Wʣ
16 17 18 19 20
DC 6Vʢ0.9Wʣ DC 5Vʢ0.9Wʣ
21 22 23 24 25 26 27 28 29 30
导线300mm
90˃
微型底板系列
PŋMŋB51
2 3
956
2 · ˞1ɿA型接插件仅对应于集成的场合。
3 通
3P系列
930

˞1ɿ3P系列的一部分有不同的机种。
12345
标准
6 7 8 9 10
AC100Vʢ1.8ʗ1.4Wʣ
AC200Vʢ1.8ʗ1.4Wʣ 11 12 13 14 15
端子箱
10 1 4 回路图 c
4S1系列 ʢ3SA1ʣ
ɹ
4K系列 ʢ3KA1ʣ
ɹ
微型底板系列
单体阀
WPŋ2BP55114˞2
个别配线集成
BN˞˞55114422

家庭电路的进户线示意图

家庭电路的进户线示意图

熔 断 器
2、熔断器 (1)作用:当电路中的电流过大时, 保险丝会自动熔断,切断电路 (2)保险丝的材料: 由电阻率大、熔点低的合金制成 (3)规格:用保险丝的额定电流来表示 (4)选用原则:选用保险丝时,应 使它的额定电流等于或稍大于电路中 的最大正常工作电流 (为什么?)
管 式 保 险 丝
3、家用电器用的插座与电灯之间 是并联
家用电器使用时如何计算电?
220v 。 。

.. 插座
电灯
安装它 起什么 作用?
(二)电能表 电能表示用来测 量用户在一定时 间内消耗多少电 能的装置 电能表要装在家 庭电路的干路上.
它装在什么位 置上?
电能表的连接
进 户 线 电 能 表
闸刀开关
火线 零线 开 关
熔断器
.. 插座
电灯
能用铜丝或铁丝代替保险丝吗?
铜丝或铁丝的熔点高,一般不会熔断,容易发 生事故。
家里有三只灯标有:“220V 5A”, 应选用额定电流是多大的保险丝?
熔断器应装在火线上还是零线上? 为什么?
断路器工作原理
正常情况下,双金属片是平直的,电路的接 触点闭合,电流正常通过;当电流过大时, 双金属片被过度加热,发生弯曲,使接触 点在弹簧拉力作用下被断开,电路切断, 从而起到电路过载或短路时保护作用。
请你露一手: 晚上你在家做作业,突然, 保险丝熔断了,你首先要做什么?
(5)电路中的电流过大的原因 ①电路中用电器总功率过大 ②发生短路: 即两根电源线(火线和零线)直接连通
[创新题] 你家要更换保险盒上的保险丝, 要求保险丝的额定电流是5安。 可你手边只有额定电流为1安、2安 和3安三种规格的保险丝,怎么办呢?
家庭电路的进户线示意图 其中接地的那根电线是零线,它与 地之间没有电压(0伏);另一根 是火线,它与地(和零线)之间有 220V的电压。

再也不用算了,电线电缆穿管配合表!

再也不用算了,电线电缆穿管配合表!

再也不用算了,电线电缆穿管配合表!
在水电施工的时候,很多电工都被要求电线穿管时,电线总的横截面积不能超过管的横截面积的40%,反过来说,管道的横截面积要是穿过该管道所有电线横截面的2.5倍以上。

这是为什么呢?很多人很纳闷,也很不明白,觉得这个浪费了!
在《GB50303-2002建筑电气工程施工质量验收规范》,《电气装置安装工程施工及GB50258-96验收规范》,《GB50327 住宅装饰装修工程规范》中,同一回路电线应穿入同一根管内,管内总根数不应超过8根。

施工规范
很明显,不论是在施工规范,还是在验收规范,对这个穿管的规定,还是非常严格和明显的,规范作为大多数人的结晶,肯定有着它的合理之处。

验收规范
那具体怎么算呢?
一根线管最多穿几根电线?
在一般的家庭装修中,我们都会使用外直径为16毫米的穿线管,管壁厚度为1毫米,我们来做个计算:
16线管半径为7毫米;那么线管的内横截面积约为154平方毫米;40%就是61.6平方毫米;
平常用到的2.5方的电线,包含绝缘层的横截面直径为3.5毫米,也就是说,2.5方电线的空间面面积为9.6平方毫米;
那么可以计算出,一根16线管中,最多也就能穿6根线,同样换算出,4方的电线,最多也就穿3根。

管道直角弯,不允许
线管内线缠绕,不合理
总之,穿管内的电线截面不能大于管径的40%,是由于安全用电的需要,绝对不是浪费,这点大家注意了,还有,如果你真的不会算,那就记住下面那张表去套吧。

是不是又很简单了?比如,3*10的BV线,用的套管应该是25的。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档
最新文档