铂钴标准比色法检测水中色度.
铂钴比色法测定水色度.
4.样品采集、保存及预处理
(1)将样品采集在容积至少为1L的玻璃瓶内,在采样后要 尽早进行测定。 (2)如果必须贮存,则将样品贮于暗处。要避免样品与空 气接触,避免温度显著变化。 (3)将样品倒入250 mL(或更大)量筒中,静置15min,倾取 上层液体备测定用。
7
国家职业教育水环境监测与治理专业教学资源库
•将溶液放在密封的玻璃瓶中,存放在温度不能超过30℃的暗处。
•溶液至少可稳定6个月。
4
国家职业教育水环境监测与治理专业教学资源库
铂钴比色法测定水色度
(3)色度标准溶液配置: •①在一组250 mL的容量瓶中,用移液管分别加入2.50,5.00, 7.50,10.00,12.50,15.00,17.50,20.00,30.00及35.00 mL储备 液,用纯水稀释至标线;则溶液色度分别为5,10,15,20,25 ,30,35,40,50,60和70度。 •②溶液放在严密益好的玻璃瓶中,存放于暗处。温度不能超过 30℃。 •③标准溶液至少可稳定1个月。
国家职业教育水环境监测与治理专业教学资源库
水环境监测
铂钴比色法测定水色度
王虎 副教授
国家职业教育水环境监测与治理专业教学资源库
铂钴比色法测定水色度
1.铂钴比色法原理
(1)色度的标准单位为“度”,规定在每升溶
液中含有2mg六水合氯化钴(IV)和1 mg铂(以
六氯铂(IV)酸)时产生的颜色为1度。
(2)用氯铂酸钾和氧化钴配制色标溶液,与被
3
国家职业教育水环境监测与治理专业教学资源库
铂钴比色法测定水色度
(2)色度标准储备液(相当于500度):
•将1.245±0.001g六氯铂(Ⅳ)酸钾(K2PtC16)和1.000±0.001g六水氯 化钴(Ⅳ)(CoCl2· 6H2O)溶于约500mL光学纯水中,加100±1mL盐
水样色度的测定
色管置于自瓷板或白纸 上,使光线从管底部向上透过 液柱,目光自管口垂直向下观察,记下与水样色度 相 同的铂钴标准色列的色度。
(二)计算 色度(度)=A*50 / B 式中: A一一-稀释后水样相当于铂钴标准色
列的色度: B一一水样的体积,mL。
实验建议:
可用重铬酸钾代替氯铀酸钾配制标准色列。方法是: 称取0.0437g重铬酸钾和1. 000g硫酸钴
(CoS04 • 7HzO) ,溶于少量水中,加入
0.50mL硫酸,用水稀释至 500mL。此溶液的 色度为500度。不宜久存。 如果水样品中有泥土或其他分散很细的悬浮物,虽 经预处理而得不到透明水样时,则只测其表色。
如水样浑浊,则放置澄清,亦可用离心法或用孔径 0.45微米滤膜过滤以去除悬浮物,但不能用滤纸过滤, 因滤纸可吸附部分溶解于水的颜色。
实验用品
仪器:50mL具塞比色管,刻度线高度应一致 试剂:铂钴标准溶液 称取1. 246g氯铂酸钾(K2PtCl6) (相当于500mg
铂)及1. 000g氯化钴 (CoClz • 6HzO) (相当于 250mg钴) ,溶于100mL水中,加100mL盐酸, 用水定容至 1000mL。此溶液色度为500度,保存 在密塞玻璃瓶中,存放暗处
方法2 稀释倍数法
一、实验目的: 掌握铂钴比色法和稀释倍数法测定水和废水
色度方法 二、实验原理: 将有色工业废水用无色水稀释到接近无色时,
记录稀释倍数,以此表示该水样的色度,并 辅以用文字描述颜色性质,如深蓝色、棕黄 色等。
三、实验用品
仪器:50mL具塞比色管,刻度线高度应一 致
四、实验操作
工业分析技术专业《色度的测定》
水中色度的测定纯洁的水是无色透明的,天然水经常呈现出一定的颜色,主要是因为植物的叶、皮、根腐殖质以及可溶性无机矿物质和泥沙造成的,地表水受工业废水污染后可使水色变得极为复杂。
“真色〞和“表色〞,可根据实际监测需要测定“真色〞和“表色〞。
测定水样色度的方法有铂钴标准比色法〔GB11903-1989〕和稀释倍数法〔GB11903-1989〕。
一、铂钴比色法测色度水是无色透明的,当水中存在某些物质时,会表现出一定的颜色。
溶解性的有机物,局部无机离子和有色悬浮微粒均可使水着色。
g铂和钴时所具有的颜色,称为1度,作为标准色度单位。
如水样浑浊,那么放置澄清,亦可用离心法或用孔径为μm滤膜过滤以去除悬浮物,但不能用滤纸过滤,因滤纸可吸附局部溶解于水的颜色。
仪器和试剂:具塞比色管,其刻线高度应一致。
2铂钴标准溶液:称取1.246g氯铂酸钾〔K2g铂〕及1.000g氯化钴〔COCl2·6H2O〕〔相当于250mg钴〕,溶于100mL水中,加100mL盐酸,用水定容至1000mL。
此溶液色度为500度,保存在密塞玻璃瓶中,存放暗处。
测定步骤:1标准色列的配制:向50mL比色管中参加0、、、、、、、、、、、及铂钴标准溶液,用水稀释至标线,混匀。
各管的色度依次为0、5、10、15、20215、30、35、40、45、50、60和70度。
密塞保存。
2水样的测定〔1〕分取澄清透明水样于比色管中,如水样色度较大,可酌情少取水样,用水稀释至。
〔2〕将水样与标准色列进行目视比拟。
观察时,可将比色管置于白瓷板或白纸上,使光线从管底部向上透过液柱,目光自管口垂直向下观察,记下与水样色度相同的铂钴标准色列的色度。
计算:式中:A——稀释后水样相当于铂钴标准色列的色度;B——水样的体积〔mL〕。
考前须知:1可用重铬酸钾代替氯铂酸钾配制标准色列。
方法是:称取0.0437g重铬酸钾和1.000g硫酸钴〔CoSO4·7H2O〕,溶于少量水中,参加硫酸,用水稀释至500mL。
铂钴比色法实验报告
铂钴比色法实验报告一、铂钴比色法原理用氯铂酸钾和氯化钴配制颜色标准溶液,与水样进行比色,与被测样品进行目视比较,以测定样品的颜色强度。
每升水中含有1mg铂和0.5mg钴时所具有的颜色,称为1度,作为标准色度单位,即色度。
样品的色度以与之相当的色度标准溶液的度值表示。
注,此标准单位导出的标准度有时称为"Hazen际"或"Pt,Co标"[GB3143 《液体化学产品颜色测定法。
Hazcn单位,铂,钴色号》]或毫克铂,升。
二、色度的意义水的色度往往会影响造纸、纺织等工业产品的质量、水的色度是对天然水或处水的色度往往会影响造纸、纺织等工业产品的质量、水的色度是对天然水或处理后的各种水进行颜色定量测定时的指标、各种用途的水对于色度都有-定的要求,如生活用水的色度要求小于15度,造纸工业用水的色度要求小于15度,30度、纺织工业的用水色度要求小于10度。
12度、染色用水的色度要求小于5度。
三、符合标准色度测定标准溶液,符合GB/T 605-2006《化学试剂色度测定通用方法》四、保存条件。
色度标准溶液存放在密封性较好的塑料/玻璃瓶中。
避光存放在暗处。
温度不能超过30C。
五、稀释、各色号铂-钴标准溶液的制备。
配制100ml所需黑曾单位的铂-钴标准溶液,应量取500黑曾单位铂钴标准溶液的体积、V、。
数值以"mL"表示,按公式计算,Nx100mI=Vx 500(Hazen)式中欲配制的铂-钴标准溶液的黑曾单位数用“N”表示。
例如:取12个容量为100mL的容量瓶,分别加入如上表中所示的标准比色母液的体积数、用蒸馏水稀释到刻度混合均匀。
即得到各个色度号的铂钴标准溶液。
稀铂-钴标准溶液应在使用前配制。
水体色度测定的实训报告
一、实训目的1. 掌握水体色度测定的原理和方法。
2. 学会使用铂钴比色法和稀释倍数法测定水体色度。
3. 培养实验操作能力和分析问题的能力。
二、实训内容1. 实验原理水体色度是指水溶液的颜色强度,通常用铂钴比色法和稀释倍数法进行测定。
铂钴比色法是将待测水样与已知浓度的铂钴标准溶液进行目视比较,以确定水样的色度。
稀释倍数法是将水样用光学纯水稀释至与光学纯水相比刚好看不见颜色的稀释倍数,以确定水样的色度。
2. 实验仪器与试剂仪器:铂钴比色计、稀释倍数比色计、烧杯、移液管、容量瓶、光学纯水、铂钴标准溶液、待测水样。
试剂:分析纯试剂。
3. 实验步骤(1)铂钴比色法①准备铂钴标准溶液:将铂钴标准溶液稀释至0、10、20、30、40、50、60、70、80、90、100倍,分别倒入比色管中。
②测定水样色度:将待测水样倒入比色管中,与标准溶液进行目视比较,记录下与水样颜色最接近的标准溶液倍数,即为水样的色度。
(2)稀释倍数法①测定水样色度:将待测水样用光学纯水稀释,逐级稀释至与光学纯水相比刚好看不见颜色的稀释倍数,记录下该稀释倍数,即为水样的色度。
4. 实验结果与分析(1)铂钴比色法通过铂钴比色法测定水样色度,记录下水样色度值。
(2)稀释倍数法通过稀释倍数法测定水样色度,记录下水样色度值。
将两种方法的测定结果进行对比分析,探讨两种方法的优缺点。
三、实训总结1. 通过本次实训,掌握了水体色度测定的原理和方法,学会了使用铂钴比色法和稀释倍数法测定水体色度。
2. 在实验过程中,培养了实验操作能力和分析问题的能力,提高了自己的动手能力。
3. 认识到实验过程中需要注意的事项,如试剂的配制、仪器的使用、数据的记录等。
4. 通过对比分析两种测定方法,了解到铂钴比色法和稀释倍数法的优缺点,为实际工作中选择合适的测定方法提供了参考。
四、实训体会1. 实验过程中,要严格按照实验步骤进行操作,确保实验结果的准确性。
2. 注意实验仪器的使用和维护,提高实验效率。
铂钴比色法测定水色度.
铂钴比色法测定水色度
5.测定步骤
(1)将一组具塞比色管用色度标准溶液充至标线,将另一组具 塞比色管用试样充至标线。 (2)将具塞比色管放在白色表面上,比色管与该表面应呈合适 的角度,使光线被反射自具塞比色管底部向上通过液柱。 (3)垂直向下观察液柱,找出与试样色度最接近的标准溶液。
8
国家职业教育水环境监测与治理专业教学资源库
5
国家职业教育水环境监测与治理专业教学资源库
铂钴比色法测定水色度
3.仪器与设备的准备
(1)具塞比色管:50mL:规格一 致,光 学透明玻璃底部无阴影; (2)pH计:精度±0.1pH单位; (3)容量瓶:规格250 mL; (4)实验室常用仪器。
6
国家职业教育水环境监测与治理专业教学资源库
铂钴比色法测定水色度
3
国家职业教育水环境监测与治理专业教学资源库
铂钴比色法测定水色度
(2)色度标准储备液(相当于500度):
•将1.245±0.001g六氯铂(Ⅳ)酸钾(K2PtC16)和1.000±0.001g六水氯 化钴(Ⅳ)(CoCl2· 6H2O)溶于约500mL光学纯水中,加100±1mL盐
酸(ρ=1.18g/mL)并在1000mL的容量瓶内用水稀释下标线。
10
国家职业教育水环境监测与治理专业教学资源库
铂钴比色法测定水色度
6.结果计算
6.2稀释水样结果表征
(1) 稀释样品色度(A0,以度计)用下式计算:
A0=A1*V1/V0
式中:V1——样品稀释后的体积,mL;
V0——样品稀释前的体积,mL;
A1——稀释样品色度的观察值,度。
(2)在报告样品色度的同时报告pH值。
4.样品采集、保存及预处理
水中色度检测法 - 铂钴视觉比色法.
水中色度檢測法 - 鉑鈷視覺比色法NIEA W201.51B 一、方法概要以視覺比色法將水樣和一系列不同色度之鉑鈷標準溶液進行比對,測定出水樣之色度,比對方式亦可以使用附有校正證明之玻璃製標準色盤進行。
一個色度單位,係指 1 mg鉑以氯鉑酸根離子(Chloroplatinate ion)態存在於1 L水溶液中時所產生之色度。
在某些特殊情況下,可改變鉑和鈷之比例,以接近水樣之色調。
一般而言,本方法所述鉑和鈷之比例,可符合自然水之色調。
本方法所測得之色度為外觀色度(Apparent color),水樣不必除去濁度。
二、適用範圍本方法適用於飲用水、地面水及地下水,但不適用於含高色度之工業廢水。
三、干擾因水樣色度常因pH值變化而改變,檢驗水樣色度時須同時測定pH 值,並於檢驗報告中註明。
四、設備(一)納式管(Nessler tubes):長型、容量可裝50 mL且有等高刻度。
(二)pH計(三)玻璃製標準色盤:附有與鉑鈷標準溶液進行校正比對之原廠證明文件。
五、試劑(一)試劑水:不含色度之蒸餾水或去離子水,以其配製試劑、清洗或稀釋樣品,使用前製備,必要時可藉由空白分析來查核試劑水,是否含有色度。
(二)標準儲備溶液1、溶解1.246 g氯鉑酸鉀(K2PtCl6)和1.00g晶狀的氯化亞鈷(CoCl2.6H2O)於含100 mL 12N濃鹽酸之試劑水(以濃鹽酸徐徐加入適量蒸餾水中)中,再以試劑水定容至1,000mL。
此標準儲備溶液之色度為500單位。
2、若無法購得可靠來源之氯鉑酸鉀時,可溶解0.500 g純鉑之金屬於王水,一面加熱以幫助溶解,然後重複加入濃鹽酸並蒸發以除去硝酸。
加入 1.00 g晶狀的氯化亞鈷,依上述方法配成色度為500單位之標準儲備溶液。
(三)標準溶液取標準儲備溶液 0.5 、 1.0 、 1.5 、 2.0 、 2.5 、 3.0 、3.5 、4.0 、 4.5 和5.0 mL,分別置於納式管中,以試劑水定容至50 mL,配成一系列色度分別為5 、10 、15 、20 、25 、 30 、 35 、 40 、 45 和50 單位之標準溶液。
新方法验证报告(水质 色度的测定 (铂钴比色法 稀释倍数法) GBT 11903-1989)
XXXX有限公司新项目方法验证能力确认报告铂钴比色法稀释倍数法项目名称:《水质色度的测定》(GB/T 11903-1989)负责人:审核人:日期:铂钴比色法稀释倍数法《水质色度的测定》(GB/T 11903-1989)方法验证能力确认报告1、方法依据及适用范围本方法依据是《水质色度的测定》(GB/T 11903-1989),本方法能力验证应随标准更新而更新。
铂钴比色法:适用于清洁水、轻度污染并略带黄色调的水,比较清洁的地面水、地下水和饮用水等。
稀释倍数法:适用于污染较严重的地面水和工业废水。
2、方法原理铂钴比色法:用氯铂酸钾和氯化钴配置颜色标准溶液,与被测样品进行目视比较,以测定样品的颜色强度,即色度。
样品的色度以与之相比较的色度标准溶液的度值表示。
稀释倍数法:将样品用光学纯水稀释至用目视比较与光学纯水相比刚好看不见颜色的稀释倍数作为表达颜色的强度,单位为倍。
3、主要仪器、设备及试剂除非另有说明,测定中仅适用光学纯水及分析纯试剂。
3.1试剂和材料3.1.1光化学纯水:将0.2μm滤膜(细菌学研究中所采用的)在100mL 蒸馏水或去离子水中浸泡1h,用它过滤250mL蒸馏水或去离子水,弃去最初的250mL,以后用这种水配制全部标准溶液并作为稀释水。
3.1.2色度标准溶液:500度,标准证书编号:XXXXXXXX,有效期限:XXXX年XX月XX日。
3.1.3色度标准使用液:在一组250mL容量瓶中,用移液管分别加入2.50,5.00,7.50,10.00,12.50,15.00,17.50,20.00,30.00及35.00mL色度标准溶液,并用光学纯水稀释至刻度。
溶液色度分别为:5,10,15,20,25,30,35,40,50,60,70度。
3.1.4标准溶液的保存:溶液放在严密盖好的玻璃瓶中,存放于暗处,温度不能超过30℃。
这些溶液至少可稳定1个月。
3.2仪器3.2.1具塞比色管,50mL。
规格一致,光学透明玻璃底部无阴影。
色度检测操作细则(铂钴标准比色法)
色度(铂钴标准比色法)方法原理用氯铂酸钾与氯化钴配成标准系列,与水样进行目视比色。
干扰及消除如水样浑浊,则放置澄清,也可用离心法或用孔径为0.45滤膜过滤以去掉悬浮物。
但不能用滤纸过滤,因滤纸可吸附部分溶解于水的颜色。
仪器50ML具塞闭塞管,其刻线高度应一致。
试剂铂钴标准溶液:称取1.246g氯铂酸钾K2PCL6(相当于500铂)及1.000氯化钴步骤标准色列的配置:向50ML比色管中加入0、0.5、1.00、1.50、2.00、2.50、3.00、3.50、4.00、4.50、5.00、6.00及7.000铂钴标准溶液,用水稀释至标线,混匀。
各管的色度依次为5、10、15、20、25、30、35、40、45、50、60和70度。
密封保存。
德信诚精品培训课程(部分)内审员系列培训课程查看详情TS16949五大工具与QC/QA/QE品质管理类查看详情 JIT>>>德信诚深圳培训中心 E-mail:55top@ 报名表下载>>> 公开课计划表水样的测定:1、分取50.0ML澄清透明水样于比色管中,如水样色度较大,可酌情少取水样,用水稀释至50.0ML。
2、将水样与标准色列进行目视比较。
观测时,可将比色管至于白瓷板或白板上,使光线从关底部向上透过液柱,目光自管口垂直向下观察。
记下与水样色度相同的铂钴标准色列的色度。
计算色度=A×50/B式中: A------稀释后水样相当于铂钴标准比色法的色度B------水样得体积(ML)注意事项可用重铬酸钾代替氯铂酸钾配置标准色列。
方法是:称取0.0437g重铬酸钾和1.000g硫酸钴(CoSo4.7H2O)溶于少量水中,加入0.50ml硫酸,用水稀释至500ml。
此溶液的色度为500度。
不宜久存,如果样品中有泥土或其它分散很散狠细的悬浮物,虽经处理而得不到透明水样时,则只测“表面颜色”。
水质色度的测定
水质色度的测定水质色度的测定GB 11903-89--------------------------------------------------------------------------------Water quality-Determination of colority1 主题内容与适用范围本标准规定了两种测定颜色的方法。
本标准测定经15min澄清后样品的颜色。
pH值对颜色有较大影响,在测定颜色时应同时测定pH值。
1.1 铂钴比色法参照采用国际标准ISO 7887—1985《水质颜色的检验和测定》。
铂钴比色法适用于清洁水、轻度污染并略带黄色调的水,比较清洁的地面水、地下水和饮用水等。
1.2 稀释倍数法适用于污染较严重的地面水和工业废水。
两种方法应独立使用,一般没有可比性。
样品和标准溶液的颜色色调不一致时,本标准不适用。
2 定义本标准定义取自国际照明委员会第17号出版物(CIE publication No.17),采用下述几条。
2.1 水的颜色改变透射可见光光谱组成的光学性质。
2.2 水的表观颜色由溶解物质及不溶解性悬浮物产生的颜色,用未经过滤或离心分离的原始样品测定。
2.3 水的真实颜色仅由溶解物质产生的颜色。
用经0.45?m滤膜过滤器过滤的样品测定。
2.4 色度的标准单位,度:在每升溶液中含有2mg六水合氯化钴(?)和1mg铂[以六氯铂(?)酸的形式]时产生的颜色为1度。
3 铂钴比色法3.1 原理用氯铂酸钾和氯化钴配制颜色标准溶液,与被测样品进行日视比较,以测定样品的颜色强度,即色度。
fast boat. "Moon Pro Power pole and offshore to quickly open bow. See trailing people around the Lake called "shake up, us a liftboat!......" Shen Yuezhen stood in the bow, holding a small pistol, briskly humming "Bella Ciao". Person she wanted to send guns to the Jiangsu Taihu anti-Japanese volunteer station, look for a long time never met comrade ... ... (13) Qian Guibao intensive care wounded soldiers during the war, Zhu Xi Yao bang Tao Yuan San Min, based in this village, where good mass base. In May 1939, Zhu Xi transfer 9 wounded guerrilla, Yao bang due to injury. Qian Guibao, consciously take on the task of caring for the wounded villagers, they are wounded daily diet, taken care of. A few days later, 3 injured from wounds, medical treatment failed, died. Qian Guibao, arranged to buy the coffin, washing the bodies, buried on the spot. After 10 days, the remaining number of wounded was ordered to transfer to other places. Qian Guibao, villagers ' enthusiasm to take care of the wounded, reflect the people's support of anti-Japanese patriotism. (14) mountain Bao Dai Xiuchang, eager to help the underground resistance movement in May 1939, the party memberZhuang Shaozhen according to instructions, came to the Tomb area car dam the resistance movement. He organized the Wujiang administrative team, run evening classes, to introduce youth to turn, the army's case against Japan, revolutionary Outlook on life education; by teaching the Feng Yang, the nation, said song, the sword marches such as songs andorganize cultural tours and other activities, mobilize the masses, unite against Japan. Scope of activities in the joy Temple works, Miao and Hui 样品的色度以与之相当的色度标准溶液(3.2.3)的度值表示。
水样中色度的测定
水样中色度的测定一、实验目的和原理目的:(1)、了解铂-钴比色法测定水样色度的基本原理;(2)、掌握水样色度测定仪器的使用及操作程序。
原理:用氯铂酸钾与氯化钴配成标准色列,与水样进行目视比色法。
每升水中含有1mg 铂和0.5mg钴时所具有的颜色,称为1度,作为标准色度单位。
二、仪器和试剂仪器:具塞比色管(25ml)试剂:铂钴标准溶液(500度)此溶液老师统一提供,配制方法:称取1.246 g 氯铂酸钾(K2PtCl6)(相当于500mg铂)及1.000g 六水合氯化钴(CoCl2 •6H2O)(相当于250mg 钴),溶于100mL水中,加100mL浓硫酸,用水定容至1000mL。
此溶液色度为500度,保存在密塞玻璃瓶中,暗处存放。
)三、实验注意事项(1)、如测定水样的真色,应放置澄清,取上清液,或用离心法去除悬浮物后测定;(2)如测定水样的表色,待水样中的打颗粒悬浮物沉降后,取上清液测定四、实验步骤(2)水样的测定:吸取25.0 mL 澄清透明水样于具塞比色管中,(由于实验器材缺少,水样浑浊,除去水样中的悬浮物只能用滤纸过滤,因滤纸可吸附部分溶解于水的有色物质,可能会使结果有点偏差)将水样与标准色列进行目视比较。
观察时可将具塞比色管置于白纸上,使光线从管底部向上透过液柱,目光自关口垂直向下观察,记录与水样色度相同的标准色列的色度。
通过比较,水样色度低于10度,再配制5度的铂钴标准溶液进行比较,通过比较水样颜色深于5度标准色列,可估计水样色度在5至10度之间。
再配制7度的标准色列,通过比较水样于标准色列色度几乎一样,可记下水样的度数大约为7度。
五、计算色度(度)=(A×25)/ V式中;A为稀释后水样相当于标准色列的色度,度;V为水样的体积,mL;25为水样稀释后的体积,即具塞比色管的容积,mL。
带入上面公式得色度(度)=(7×25)/ 25 = 7 (度)。
水质 色度的测定方法
水质色度的测定方法1含义本方法测定经15min澄清后样品的颜色,pH值对颜色有较大影响,在测定颜色时应同时测定pH值。
1.1 铂钴比色法参照采用国际标准ISO7887-1985《水质颜色的检验和测定》。
铂钴比色法适用于清洁水、轻度污染并略带黄色调的水,比较清洁的地面水、地下水和饮用水等。
1.2 稀释倍数法适用于污染较严重的地面水和工业废水。
样品和标准溶液的颜色色调不一致时,本标准不适用。
2 定义本标准定义取自国际照明委员会第17号出版物(CIE publication No.17)。
2.1 水的颜色改变透射可见光光谱组成的光学性质。
2.2 水的表观颜色由溶解物质及不溶解性悬浮物产生的颜色,用未经过滤或离心分离的原始样品测定。
2.3 水的真实颜色仅有溶解物质产生的颜色,用经0.45um滤膜过滤器过滤的样品测定。
2.4 色度的标准单位,度;在每升溶液中含有2mg六水合氯化钴(Ⅱ)和1mg铂(以六氯铂(Ⅳ)酸的形式)时产生的颜色为1度。
3 铂钴比色法3.1 原理用氯铂酸钾和氯化钴配制颜色标准溶液,与被测样品进行目视比较,以测定样品的颜色强度,即色度。
样品的色度以与之相当的色度标准溶液(3.2.3)的度值表示。
注:此标准单位到处的标准度有时称为“Hazen标”或“Pt-Co标”[GB3143《液体化学产品颜色测定法(Hazen单位——铂钴色号)》]、或毫克铂/升。
3.2 试剂除另有说明外,测定中仅使用光学纯水(3.2.1)及分析纯试剂。
3.2.1 光学纯水:将0.2um滤膜(细菌学研究中所采用的)在100mL蒸馏水或去离子水中浸泡1H,用它过滤250mL蒸馏水或去离子水,弃去最初的250mL,以后用这种水配制全部标准溶液并作为稀释水。
3.2.2 色度标准储备液,相当于500度,将1.245±0.001g六氯铂(Ⅳ)酸钾(K2PtCl6)及1.000±0.001g六水氯化钴(Ⅱ)(CoCl2.6H2O)溶于约500mL水(4.1)中,加100±1mL盐酸(ρ=1.18g/mL)并在1.000mL的容量瓶内用水稀释至标线。
水质色度的测定GB11903-89
水质色度的测定GB11903-89水质色度的测定GB 11903-89批准日期1989-09-01实施日期1989-09-01水质色度的测定GB 11903-89Water quality-Determination of colority1 主题内容与适用范围本标准规定了两种测定颜色的方法。
本标准测定经15min澄清后样品的颜色。
pH值对颜色有较大影响,在测定颜色时应同时测定pH 值。
1.1 铂钴比色法参照采用国际标准ISO 7887—1985《水质颜色的检验和测定》。
铂钴比色法适用于清洁水、轻度污染并略带黄色调的水,比较清洁的地面水、地下水和饮用水等。
1.2 稀释倍数法适用于污染较严重的地面水和工业废水。
两种方法应独立使用,一般没有可比性。
样品和标准溶液的颜色色调不一致时,本标准不适用。
2 定义本标准定义取自国际照明委员会第17号出版物(CIE publication No.17),采用下述几条。
2.1 水的颜色改变透射可见光光谱组成的光学性质。
2.2 水的表观颜色由溶解物质及不溶解性悬浮物产生的颜色,用未经过滤或离心分离的原始样品测定。
2.3 水的真实颜色仅由溶解物质产生的颜色。
用经0.45μm滤膜过滤器过滤的样品测定。
2.4 色度的标准单位,度:在每升溶液中含有2mg六水合氯化钴(Ⅳ)和1mg铂[以六氯铂(Ⅳ)酸的形式]时产生的颜色为1度。
3 铂钴比色法用氯铂酸钾和氯化钴配制颜色标准溶液,与被测样品进行日视比较,以测定样品的颜色强度,即色度。
样品的色度以与之相当的色度标准溶液(3.2.3)的度值表示。
注:此标准单位导出的标准度有时称为“Hazen际”或“Pt-Co 标”[GB 3143《液体化学产品颜色测定法(Hazcn单位——铂-钴色号)》]、或毫克铂/升。
3.2 试剂除另有说明外,测定中仅使用光学纯水(3.2.1)及分析纯试剂。
3.2.1 光学纯水:将0.2μm。
滤膜(细菌学研究中所采用的)在100mL蒸馏水或去离子水中浸泡1h,用它过滤250mL蒸馏水或去离子水,弃去最初的250mL,以后用这种水配制全部际准溶液并作为稀释水。
色度检测操作细则(铂钴标准比色法)
色度(铂钴标准比色法)方法原理用氯铂酸钾与氯化钴配成标准系列,与水样进行目视比色。
干扰及消除如水样浑浊,则放置澄清,也可用离心法或用孔径为0.45滤膜过滤以去掉悬浮物。
但不能用滤纸过滤,因滤纸可吸附部分溶解于水的颜色。
仪器50ML具塞闭塞管,其刻线高度应一致。
试剂铂钴标准溶液:称取1.246g氯铂酸钾K2PCL6(相当于500铂)及1.000氯化钴步骤标准色列的配置:向50ML比色管中加入0、0.5、1.00、1.50、2.00、2.50、3.00、3.50、4.00、4.50、5.00、6.00及7.000铂钴标准溶液,用水稀释至标线,混匀。
各管的色度依次为5、10、15、20、25、30、35、40、45、50、60和70度。
密封保存。
德信诚精品培训课程(部分)内审员系列培训课程查看详情TS16949五大工具与QC/QA/QE品质管理类查看详情 JIT>>>德信诚深圳培训中心 E-mail:55top@ 报名表下载>>> 公开课计划表水样的测定:1、分取50.0ML澄清透明水样于比色管中,如水样色度较大,可酌情少取水样,用水稀释至50.0ML。
2、将水样与标准色列进行目视比较。
观测时,可将比色管至于白瓷板或白板上,使光线从关底部向上透过液柱,目光自管口垂直向下观察。
记下与水样色度相同的铂钴标准色列的色度。
计算色度=A×50/B式中: A------稀释后水样相当于铂钴标准比色法的色度B------水样得体积(ML)注意事项可用重铬酸钾代替氯铂酸钾配置标准色列。
方法是:称取0.0437g重铬酸钾和1.000g硫酸钴(CoSo4.7H2O)溶于少量水中,加入0.50ml硫酸,用水稀释至500ml。
此溶液的色度为500度。
不宜久存,如果样品中有泥土或其它分散很散狠细的悬浮物,虽经处理而得不到透明水样时,则只测“表面颜色”。
水质中常规项目的检测方法
——铂—钴标准比色法1、取50ml透明的水样于比色管中(如水样色度过高,可少取水样,加纯水稀释后比色)。
2、另量比色管11支,分别加入铂—钴标准溶液0,,,,,,,,,及,加纯水至刻度,摇匀,即配制成色度为0,5,10,15,20,25,30,35,40,45及50度的标准色列,可长期使用。
3、将水样与铂—钴标准色列比较。
4、计算:C=M/V×500C—水样的色度M—相当于铂—钴标准溶液用量,mlV—水样体积,ml浑浊度——目视比浊法1、吸取浑浊度为400NTU的标准混悬液0ml,,,,,,,和分别置于成套的50ml比色管内,加纯水至刻度,摇匀后即得浑浊度为0NTU,2NTU,4NTU,8NTU,10NTU,20NTU,30NTU,及40NTU的标准混悬液。
2、取50ml摇匀的水样,置于同样规格的比色管内,与浑浊度标准混悬液系列同时振摇均匀后,由管的侧面观察,进行比较,水样的浑浊度超过40NTU时,可用纯水稀释后测定。
水中PH值测定——玻璃电极法1、玻璃电极在使用前应放入纯水中浸泡24小时以上。
2、用PH标准缓冲溶液(PH=)检查仪器和电极必须正常。
3、测定时用接近于水样PH的标准缓冲溶液校准仪器刻度。
4、用洗瓶以纯水缓缓淋洗两电极数次,再以水样淋洗6~8次,然后插入水样中,1分钟后直接从仪器上读出PH值。
水中总硬度的测定——乙二胺四乙酸二钠滴定法1、吸取50ml水样置150ml三角瓶中。
2、加2ml缓冲溶液再加一小勺铬黑T指示剂。
3、立即用EDTA-2N a L)标液滴定,当溶液由紫红色刚变为纯兰色时即为滴定终点。
同时做空白对照。
4、计算C(CaCO3)—水样总硬度mg/LV0—空白消耗EDTA-2N a 标准溶液的量mlV1—样品消耗EDTA-2N a标准溶液的量mlC—EDTA-2N a 标准溶液的浓度mol/LV—水样体积ml水中氨氮的测定——纳氏试剂分光光度法1、吸取澄清水样于50ml比色管中,向水样管中加C(CaCO3)=(V1-V0)×C××1000V入1ml酒石酸钾钠溶液(500g/L),混匀。
铂钴标准比色法检测水中色度.
色度(铂钴标准比色法方法原理用氯铂酸钾与氯化钴配成标准系列,与水样进行目视比色。
如水样浑浊,则放置澄清,也可用离心法或用孔径为0.45 滤膜过滤以去掉悬浮物。
但不能用滤纸过滤,因滤纸可吸附部分溶解于水的颜色。
仪器50ML 具塞闭塞管,其刻线高度应一致。
试剂铂钻标准溶液:称取1.246g氯铂酸钾K2PCL6(相当于500铂及1.000六水合氯化钻(相当于250mg钻,溶于水中,加100ml浓盐酸,用水定容至1000ml。
此溶液色度为500度,保存在密塞玻璃瓶中,暗处存放。
步骤标准色列的配置:向50mL 比色管中加入0mL、0.5mL、1.00mL、1.50mL、2.00mL、2.50mL、3.00mL、3.50mL、4.00mL、4.50mL、5.00mL、6.00mL 及7.000mL 铂钻标准溶液, 用水稀释至标线,混匀。
各管的色度依次为5、10、15、20、25、30、35、40、45、50、60和70度。
密封保存。
水样的测定:1、分取50.0ML 澄清透明水样于比色管中,如水样色度较大,可酌情少取水样,用水稀释至50.0ML 。
2、将水样与标准色列进行目视比较。
观测时,可将比色管至于白瓷板或白板上使光线从关底部向上透过液柱,目光自管口垂直向下观察。
记下与水样色度相同的铂钴标准色列的色度。
计算色度=A X50/V式中: A --- 稀释后水样相当于铂钴标准比色法的色度V --- 水样得体积(ML注意事项可用重铬酸钾代替氯铂酸钾配置标准色列。
方法是:称取0.0437g 重铬酸钾和1.000g七水合硫酸钻(CoSo4.7H20溶于少量水中,加入0.50ml硫酸用水稀释至500ml。
此溶液的色度为500度。
不宜久存,如果样品中有泥土或其它分散很散狠细的悬浮物,虽经处理而得不到透明水样时,则只测“表面颜色”。
实验二水样色度的测定-实验一水样悬浮物和浊度的测定
实验二水样色度的测定1 实验目的(1)明确水体物理指标对水质评价的意义;(2)掌握色度指标的测定方法。
2 测定方法天然和轻度污染水可用铂钴比色法测定色度,对工业有色废水常用稀释倍数法辅以文字描述。
2.1 铂钴标准比色法2.1.1原理用氯铂酸钾与氯化钴配成标准色列,与水样进行目视比色。
每升水中含有1mg铂和0.5mg钴时所具有的颜色,称为1度,作为标准色度单位。
如水样浑浊,则放置澄清,亦可用离心法或用孔径为0.45μm滤膜过滤以去除悬浮物,但不能用滤纸过滤,因滤纸可吸附部分溶解于水的颜色。
2.1.2 仪器和试剂(1)50mL具塞比色管,其刻线高度应一致。
(2)铂钴标准溶液:称取1.246g氯铂酸钾(K2PtC16)(相当于500mg铂)及1.000g 氯化钴(COCl2·6H2O)(相当于250mg钴),溶于100mL水中,加100mL盐酸,用水定容至1000mL。
此溶液色度为500度,保存在密塞玻璃瓶中,存放暗处。
2.1.3 测定步骤(1)标准色列的配制:向50mL比色管中加入0、0.50、1.00、1.50、2.00、2.50、3.00、3.50、4.00、4.50、5.00、6.00及7.00mL铂钴标准溶液,用水稀释至标线,混匀。
各管的色度依次为0、5、10、15、20、25、30、35、40、45、50、60和70度。
密塞保存。
(2)水样的测定a. 分取50.0mL澄清透明水样于比色管中,如水样色度较大,可酌情少取水样,用水稀释至50.0mL。
b. 将水样与标准色列进行目视比较。
观察时,可将比色管置于白瓷板或白纸上,使光线从管底部向上透过液柱,目光自管口垂直向下观察,记下与水样色度相同的铂钴标准色列的色度。
2.1.4 计算式中:A——稀释后水样相当于铂钴标准色列的色度;B——水样的体积(mL)。
2.1.5 注意事项(1)可用重铬酸钾代替氯铂酸钾配制标准色列。
方法是:称取0.0437g重铬酸钾和1.000g 硫酸钴(COSO4·7H2O),溶于少量水中,加入0.50mL硫酸,用水稀释至500mL。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
注意事项
可用重铬酸钾代替氯铂酸钾配置标准色列。方法是:称取0.0437g重铬酸钾
和1.000g七水合硫酸钴(CoSo4.7H2O溶于少量水中,加入0.50ml硫酸,用水稀释至500ml。此溶液的色度为500度。不宜久存,
如果样品中有泥土或其它分散很Fra bibliotek狠细的悬浮物,虽经处理而得不到透明水
样时,则只测“表面颜色”。
色度
(铂钴标准比色法
方法原理
用氯铂酸钾与氯化钴配成标准系列,与水样进行目视比色。
如水样浑浊,则放置澄清,也可用离心法或用孔径为0.45滤膜过滤以去掉悬
浮物。但不能用滤纸过滤,因滤纸可吸附部分溶解于水的颜色。
仪器
50ML具塞闭塞管,其刻线高度应一致。
试剂
铂钴标准溶液:称取1.246g氯铂酸钾K2PCL6(相当于500铂及1.000六水合氯化钴(相当于250mg钴,溶于水中,加100ml浓盐酸,用水定容至1000ml。
此溶液色度为500度,保存在密塞玻璃瓶中,暗处存放。
步骤
标准色列的配置:
向50mL比色管中加入0mL、0.5mL、1.00mL、1.50mL、2.00mL、2.50mL、3.00mL、3.50mL、4.00mL、4.50mL、5.00mL、6.00mL及7.000mL铂钴标准溶液,用水稀释至标线,混匀。各管的色度依次为5、10、15、20、25、30、35、40、45、50、60和70度。密封保存。
水样的测定:
1、分取50.0ML澄清透明水样于比色管中,如水样色度较大,可酌情少取水样,用水稀释至50.0ML。
2、将水样与标准色列进行目视比较。观测时,可将比色管至于白瓷板或白板上,使光线从关底部向上透过液柱,目光自管口垂直向下观察。记下与水样色度相同的铂钴标准色列的色度。
计算
色度=A×50/V
式中: A------稀释后水样相当于铂钴标准比色法的色度