ZHENGZHOU BAI-OTT NEW MATERIAL CO.,LTD中国. 郑州佰欧特新材料有限公司Tire regroover user manualPlease read this manual before power-onPacking listStructureFeature1. T his Machine is voltage-regulation for changing h eat temperature,the screen display for voltage value.2. T his machine is instantly heating,nearly no need wait f or warm-up.3. T his machine is overtemperature protection,just change a anew fuse to restart.4. T he inchingswitch buffer can keep good connection.refrain from Point-Point switch long time work will be poor connection.5.The pilot lamp just light when heating.6.The heat radiating window and one more electric fans can make sure machine have good heat radiating. Preparations before operation1. Please check if the power voltage is coincident with this machine .2. P lease put tire regroover at dry and flat floor.3. P lease choose only the powersocket with earthing4.conductor.Operation1. P lease select the right size blade and install onto the blade holder.2. P lease insert the power plug into the qualified p ower socket.3. P lease select the right size blade and install onto the blade holder.4. P lease insert the power plug into the qualified p ower socket.5. 5.If the pushing feels hard,please turn the voltage higher(C W), if the rubber fume quickly,please turn the voltage lower(A W).6. P lease do not let the blade heated ceaselessly,please let the blade off the tire for seconds after minutes working.7. I f operation finish or want to change other size blade,please let the blade free-cooling for 10 minute,then collecting or change blade.8. I f operation finish,please draw the power plug by hand,do not pluck the power cable, and turn the voltage knob to origin point.9.P lease keep the tire regroover into tool box or suitable p lace, make sure children can not catch it.。
尼普洛透析机故障报警一览表
故障报警一览表E01 停电后的启动E36 (A腔)vca密闭回路故障(负压)E02 T1温度计故障E37 (A腔)vca密闭回路故障(负压)E03 T2温度计故障E38 (B腔)vcb密闭回路故障(负压)E04 T3温度计故障E39 (B腔)vcb密闭回路故障(负压)E05 透析液温度上限报警E40 (A腔)vca密闭回路故障(正压)E06 透析液温度下限报警E41 (A腔)vca密闭回路故障(正压)E07 透析液压上限(+400mmHg以上)E42 (B腔) vcb密闭回路故障(正压)E08 透析液压下限(-400mmHg时)E43(B腔)vcb密闭回路故障(正压)E09 透析液压上限报警(超过设定值时)E44 除气槽故障E10 透析液压下限报警(超过下限值时)E45 检测到保险丝断线E11 静脉压上限(超过+400mmHg时)E46 自我检测系统故障E12 静脉压下限(低于-400mmHg时)E47 RAM故障E13 静脉压上限报警(超过上限设定值)E48 EEPROM故障E14 静脉压下限报警(超过下限设定值)E49 EOROM故障E15 动脉压上限(超过+400mmHg时)E50 ROM初始化E16 动脉压低于(-400mmHg)下限E51 EEPROM初始化E17 动脉压上限报警(超过上限设定值)E52 开关故障(电源开关)E18 动脉压下限报警(超过下限设定值)E53 I/0接口故障E19 TMP(静脉压值-液压值)超过报警设定值时E54 接头故障SBY0151-SBY0156E20 透析液电导率上限报警E55 血泵备用电源故障E21 透析液电导率下限报警E56 快速接头开关DN报警(透析)E22 漏血传感器故障E57 快速接头开关DN报警(准备)E23 漏血报警E58 快速接头开关OFF报警E24 检测到气泡E59 除水上限报警E25 加热器过热报警E60 注射泵注射完了E26 供水部足E61 注射泵注射时间到了E27 透析液流量不足E62 预充结束E28 透析液流量停止E63 到达目标除水量E29 单针开关时间报警E64 无水洗E30 血泵故障E65 透析液接头忘接E31 血泵停止报警E66 清洗接头忘接E32 夹钳位置故障E67 复位开关E33 硅油故障(vpa)E68 除水透析开关E34 硅油泵故障(vpb)E69 旁路开关E35 硅油泵容积上限。
氧化锆
氧含量在线分析系统使用说明书福州福光百特自动化设备有限公司FB-OSP01,FB-OSP02氧含量在线分析系统★ 概述:FB-OSP系统由FBP氧探头,XMOA系列氧含量分析变送仪组成。
氧探头和变送器可以一起安装在测量现场,通过4-20mA 将检测的氧含量值远传(FB-OSP01系统),也可以将氧探头和氧含量分析仪分别安装在现场和控制室(FB-OSP02系统)。
主要应用于:冶金行业的均热炉、热风炉、加热炉等;石化行业的加热炉,萃取炉,反应炉等工业加热装置中,以及电厂锅炉,热力锅炉,焚烧炉等工业锅炉中。
★ 综合技术参数:1、氧探头测量气氛温度:0-700℃(氧探头采用316材质采样管),0-900℃(氧探头采用310S材质采样管),2、变送器输出类型:0-10mA,4-20mA,0-5v,1-5v隔离变送输出3、变送器报警输出:两路报警输出4、变送器通讯:RS485隔离通讯5、系统量程范围:0.01-20.9 O2%6、系统响应时间:在探头测量端被测气氛变化时: 1-5秒,与样气流速有关。
在探头标定孔输入标气时:3秒内达到95%响应值7、系统安装环境:氧探头安装环境温度:-10—60℃(标准型)或-20—120℃(高温环境型);变送器及氧探头维护仪安装环境温度:-10—50℃; 湿度<90%8、结构:氧探头采用防爆接线盒,防水设计,可露天安装;变送器及维护仪均为壁挂形式,均为防水设计,可露天安装。
9、氧探头有效长度:1000mm,1500mm,2000mm,特殊定制长度。
10、氧探头采样管材料:SUS316,SUS310S★ 系统配置:FB-OSP01系统配置该系统为现场变送系统,包含FBP氧探头,XMOA5000现场氧含量变送器,以及吹扫及维护装置,系统配置图见图(1)。
★ 系统主要设备介绍:1、FBP氧探头:FBP氧探头采用成套进口的澳大利亚SIRO2(二氧化锆)氧传感器和陶瓷加热器,测量精度高,使用寿命长。
德国制造的LEUTERT型号50发动机压力监测仪说明书
Engine Indicator Type 50Cylinder Pressure MonitoringThe mechanical pressure indicator type 50 measures dynamicpressures. It is especially designed to analyze large two stroke Dieselengines.2Engine Indicator Type 50MADEINGERMANYSubject to change without notice. Issued 08/2023Features• Individually calibrated high accuracy heat treated springs• Rugged and proven design• Easy and simple operation by unskilled operator • Cheapest way to analyze your engine • Ready-to-use equipmentStandard accessories1 wooden box, 1 stand for instrument, 1 cord tightening hook, 1 hollow spanner, 1 operating instructions, 1 tube incl. 5 recording pencils,1 cylinder cleaner, 1 block indicator paper each 40 sheets, 1 spring, 1 measuring scaleDescriptionThe LEUTERT engine indicators are used to draw a single graph of the dynamic pressures in a combustion engine cylinder against the cylinder volume. This so called a P-V curve or indicator diagram can be used to diagnose problems such as leaking valves or incorrect timing. The LEUTERT indicators can be used for any reciprocating engine.To operate the indicator a sheet of paper is wrapped around the drum. The indicator is mounted to the cylinder head of the engine to be measured. The engine needs to be equipped with an indicator valve to do so. The indicator cord may be pulled manually to rotate the indicator drum. The drum is returned by an incorporated spring. Alternatively the cord may be connected to the cam shaft of the engine so that the drum rotates backwards and forwards with the motion of the piston. If connected to the cam shaft, the circumference of the graph indicates the power of the cylinder. A pen arm is linked to a spring bellow that is connected through a pipe to a valve in the cylinder head. The pressure in the cylinder head moves the pen along the axis of the drum to complete the pressure volume graph.The sectional drawing of the indicator shows that the bottom part is mounted in the drum support by means of a slotted nut. Depending on the expected maximum pressure, two types of bottom parts are available: One bottom part for the piston rod 1/5 and one for the piston rod 1/10. The upper part consists of the recording mechanism, the piston rod and the ring nut. The recording pencil of the indicator type 50 is interchangeable. To be able to measure higher pressure, the LEUTERT Indicators can be equipped with a smaller piston size. Corresponding to smaller piston size, higher pressure ranges can be indicated with the same spring.The spring is a double-coiled, easily interchangeable tension spring. All springs are precisely calibrated and marked with the spring number corresponding to the max. pressure rating. When selecting springs, note that the highest frequency of natural vibration can be obtained by using the largest piston possible with appropriately strong spring.Every single device is being tested and calibrated according to our ISO 9001 quality standards and will be supplied with a calibration certificate proving the accuracy of the device.Piston 1/10, Diameter 6.41 mmTechnical specificationsTable of Indicator Springs。
压力控制器使用说明
压力控制器以及压力开关产品使用手册目录第一章MD-S200 电池供电型数字压力表使用手册第二章MD-S500数字式远传型压力表使用手册第三章MD-S600高精度智能压力开关使用手册第四章MD-S700机械式压力开关使用手册第五章MD-S800低成本压力开关使用手册第六章MD-S910W/910C水泵压力控制器/空压机控制器使用手册第七章MD-S910F分体式压力控制器使用手册第八章MD-S系列产品的安装与电气连接第九章MD-S系列产品的日常养护第十章产品的运输与保存第十一章常见故障及解决办法第十二章 MD-S系列产品质量保证服务主要特点:※技术先进,质量控制体系严格,通过权威认证※设计时的第一原则是:实用及安全的原则※全系列通过权威认证注意:1.请留意手册中出现的带有※(!)(?)等提醒字样的语言!2.文中出现的“不得”“禁止”等明显禁止的语言时,请注意严格按照其要求操作。
第1章MD-S200电池供电型数字压力表MD-S200电池供电型智能压力表是是集压力测量、显示一体的高精度电子式压力表,具有抗震动、显示精度高、使用寿命长、可清零、自动待机等特点。
无需外接电源,电池供电时间长,具有自动待机与一键清零功能,使用方便,应用领域广泛。
一.外形图1.压力显示窗口2.设置键(SET)3.压力安装接口二.系统参数压力量程0-1.6MPA 或定制量程安装接口M20*1.5精度等级0.5%显示位数4位LCD显示背光蓝色背光尺寸直径100mm 厚度48m供电 4.5V 三节5号电池功耗0.001W电池更换通常每12个月更换一次电池(以实际使用耗电量为准)使用温度-20~60℃功能 1.实时显示压力 2.自动休眠 3.一键清零 4.单位切换三.按键定义说明设置键(SET)键:1.短按SET键一次,背光亮。
2.连续短按SET键,压力的显示单位在Mpa,Kg,PSI之间切换,默认单位为Mpa。
四.一键清零功能操作方法:长按SET键5秒,可以一键清零。
百特数显表操作方法(完整资料).doc
此文档下载后即可编辑百特智能数显表说明书工作状态下按SET显示LOCY→按SET输入密码18→按SET显示RAN9→按SET通过△▽选择分度号→按SET 显示Poin设置小数点→按SET显示r9.00设置量程下限→按SET显示r9.FS设置量程上限工作状态下按SET→通过△▽选择COrr按SET显示old.1→按SET通过△▽修正温度值参数设定说明:Locy:菜单上锁操作入口;按SET键确认;按△▽键退出;开锁密码为18Ran9.:分度号和量程设置入口;按SET键确认;按△▽键退出0-10/…/y:分度号设置;按△▽键设置;按SET确认PoIn:小数点位置设置;按△▽键设置;按SET确认R9.00:量程零点设置;按△▽键设置;按SET确认R9.FS:量程满度设置;按△▽键设置;按SET确认Corr:量程迁移和滤波时间设置菜单入口;按SET键确认;按△▽键取消Old.1:修正温度值;按△▽键设置;按SET确认按键说明:△:变更参数设定时,用于增加数值SET:参数设定确认键▽:变更参数设定时,用于减少数值常见故障处理:仪表通电不亮:供电电源未接入,正确接入仪表电源;接触不良,取出表芯确认弹片接触是否良好。
LED屏显示:broy分度号选择错,选择与输入信号相符的分度号;输入信号太大,调节与输入信号保证在仪表范围内;信号短线,正确接入信号线。
H.oFL.分度号选择错,选择与输入信号相符的分度号;输入信号太大,调节与输入信号保证在仪表范围内;仪表标定错误,选择正确标定信号重新标定。
L.Ofl.: 选择与输入信号相符的分度号;输入信号太小,调节与输入信号保证在仪表范围内;仪表标定错误,选择正确标定信号重新标定昌辉SWP系列智能仪表说明书控制方式:1、正确的接线仪表卡入表盘后,请参照仪表随机接线图接妥输入、输入及电源线,并请确认无误。
2、仪表的上电本仪表与电源开关,接入电源即进入工作状态。
3、仪表设备号及版本号的显示仪表在投入电源后,可立即确认仪表设备号及版本号。
百特血透机故障维修实例分析
百特血透机故障维修实例分析吴观友【摘要】百特血透机在使用过程中操作简单,维护方便.本人在维修百特1550型血透机经常见到的一些故障现象,以下就这些故障及排除方法等,做一些简单的分析.rn1故障一rn1.1故障现象rn正常开机,机器进行自检,在自检的过程中,当进出流量检测差异过大,流量检测不过,流量报警,窗口出现"FL01"代码,此种情况极为常见.rn1.2原理分析rn流量检测原理:在透析液通路中,所有液体通过射流环系统直接进入转子仓,射流环好比是一个液体"轴承",使转子能在其中悬浮转动.当转子旋转时,反射器在2个光纤束下移动.一个光纤把光从发射灯引导到转子仓中,当反射区在光纤束下移动时,光通过相邻的光束返回到光敏三极管产生一个电脉冲送到计算机内,然后被计数.【期刊名称】《医疗卫生装备》【年(卷),期】2011(032)011【总页数】1页(P149)【作者】吴观友【作者单位】510632 广州暨南大学附属第一医院设备工程科【正文语种】中文【中图分类】TH772.1百特血透机在使用过程中操作简单,维护方便。
本人在维修百特1550型血透机经常见到的一些故障现象,以下就这些故障及排除方法等,做一些简单的分析。
正常开机,机器进行自检,在自检的过程中,当进出流量检测差异过大,流量检测不过,流量报警,窗口出现“FL01”代码,此种情况极为常见。
流量检测原理:在透析液通路中,所有液体通过射流环系统直接进入转子仓,射流环好比是一个液体“轴承”,使转子能在其中悬浮转动。
当转子旋转时,反射器在2个光纤束下移动。
一个光纤把光从发射灯引导到转子仓中,当反射区在光纤束下移动时,光通过相邻的光束返回到光敏三极管产生一个电脉冲送到计算机内,然后被计数。
在2个反光区之间的旋转距离精确地代表37.88 μL的液体体积。
(1)机器长期使用酸洗不够,引起碳酸钙和氢氧化铁微粒卡在流量传感器的射流环上,使得光电计数行动受阻,在规定时间内未被检测到位[1],即会引起“FL01”报警。
Agilent 1100系列HPLC在线脱气机 说明书
带有Seal Wash的泵头结构图
3 2
}1
Agilent 四元/二元/单元泵日常维护
如何更换溶剂出口过滤芯
Agilent 四元/二元/单元泵日常维护
严重污染的溶剂出口过滤芯
如何更换活塞杆密封圈
Agilent 1100 系列泵使用须知
Agilent 1100 系列泵的使用须知
当泵头安装有冲洗附件时,由于该附件中也有密封垫,这样就
会增加活塞杆运动时的阻力。所以开泵前一定要用10%异丙醇,
并将其流速调至约20滴/分钟使这溶液流过冲洗装置。
10%异丙醇有助于降低水的表面张力,并有抑菌作用。不要用
其它溶剂代替。
当泵头安装有冲洗附件而不开启10%异丙醇,会使密封垫及活塞
Agilent 1100系列HPLC
Agilent 1100 在线脱气机-在线脱气机 (G1322A/G1379A)
工作原理
何时需要使用Agilent 1100在线脱气机
脱气机的操作
标准脱气机(G1322A)
标准脱气机每个通道体积为12ml,建议排液操作:5ml/min 排6min以上。
微脱气机(G1379A).
2.如何简单判断脱气机腔体或溶剂过滤头是否堵塞?
关闭泵,拧开脱气机出口或比例阀入口管线,此时溶剂会因为重力流出,脱气机或溶剂
。 过滤头堵塞时,溶剂会流出不畅或不流出
Agilent 1100 四元泵 (G1311A)
Agilent 1100 四元泵工作原理
Agilent 1100 泵
Agilent 1100 泵头(Pump Head)结构图
[例] 1 DRAW 5μL(抽取5μL样品) 2 NEEDLE WASH vial 7(洗针到7号瓶) 3 INJECT(进样)
百特仪表与VB6.0通讯(读瞬时值)
百特通讯协议主机发送:DC1 AAA CC ETXDC1(11H):读瞬时值AAA :从机地址码(=001~254)CC :通道号(=01-99)ETX(03H):主机结束符从机回送:STX AAA CC US MM US DDDDDDD US EEEE US SSSSS ETBSTX(02H):从机起始符AAA :从机地址码(=001~254)CC :通道号(=01-99)US(1FH):参数间隔符MM :表型字(=00~99)DDDDDDD :瞬时值(-32167~32767,32767=brok,16000=H.oFL,-2000=L.oFL,小数点在实际位置)EEEE :报警1~4报警状态(E=0:OFF E=1:ON)SSSSS :校验和5位十进制=00000~65535,从STX到最后一个US间每个字符ASC值的和,再除以65536的余数)ETB(17H):从机结束符Vb6.0指令代码Public GGdizhi As String '数显表地址(如:00101)Public Shuzhi As Single '采样数据的数值Public Sub RS485QuYang() 'RS485取样On Error Resume NextDim Quy As String '取样Dim i As IntegerDim ShuZhiF As SingleStatic ii As IntegerGGdizhi = "00101"Form1.MSComm1.InputLen = 0If Form1.MSComm1.PortOpen = True Then GoTo ddForm1.MSComm1.PortOpen = Truedd:'“00101”中的“001”代表地址号,“01”代表通道号Form1.MSComm1.Output = Chr$(18) + GGdizhi + Chr$(31) + "13" + Chr$(3)Form1.Timer1.Enabled = TrueDo '延时150msDoEventsLoop Until Form1.Timer1.Enabled = FalseShuZhiF = ShuzhiQuy = Form1.MSComm1.InputForm1.MSComm1.InBufferCount = 0Shuzhi = 0 '置零If Len(Quy) = 22 ThenShuzhi = Val(Trim(Str(Mid(Quy, 11, 5))))End IfIf Form1.MSComm1.PortOpen = False Then GoTo eeForm1.MSComm1.PortOpen = Falseee:End Sub。
百特机Baxter1550使用指引
百特机Baxter1550使用指引1、确定水处理已正常运行,开机:将机器右下角圆形按钮开至Normalize,将机器右侧A(红色)B(蓝色)液头接到A、B液捅,观察Arterial pressure和TMP pressure是否在0位。
如不是,需将压力调至0位进行测试。
2、测试时机面中间显示屏将显示由C99倒计数至0,再从U25倒数至0,如机器测试完成,显示屏将全部显示为0,显示电导率和机温上的灯为绿灯和黄灯,此时可进行循管或进行治疗。
3、接透析器和管路前,需将机器右下角的圆形按钮打至Dialyze处,开泵前,检查左下角空气检测夹是否开放状态,如弹出,需将其推入机器,此时血泵(Blood pump)才可开动。
4、治疗状态:引血完成后,静脉壶放入静脉壶位置,静脉回路管放入空气检测夹,并将左侧空气检测器打至(Focam Detector Armed(向上)检测状态,开放将买测压夹,开大血流量,调好治疗时间和超滤量,按下Hrs Remouiming start键(绿灯亮)按下Arterial pressure V enous pressure、TMP pressure open键,机器进入治疗状态,mute左侧绿灯亮,如有黄灯闪烁,应检查是否没弄好的地方。
右侧侧板显示屏可观察:(ondcms/cm)(电导率)Temp(℃) Blood 调节后要按Enter键确认,取消按skip键。
5、治疗结束:按压arterial pressur\ venous pressure \ TMP pressure open键(打开监测,调小血流至100ml/min,夹闭静脉测压夹,按下(向下)Foam Detector键,进行回血。
6、除钙:回血后检查透析时间是否为0,否将其调至0位,将管路放回原位,A、B液放接头放回A、B液孔,将机器右下角圆形按钮快速打至Disinfect键,同时轻轻顶住静脉壶夹杆(以防调出太快损耗机器)将除钙接头(黄色头)接上A、B液孔上孔,向机器前方旋45度角,机器即开始进行除钙。
百特Accure床边血液滤过系统常见故障维修及紧急处理
收稿日期:2009-04-13百特Accure 床边血液滤过系统常见故障维修及紧急处理徐靖宁,姚向峰,郑 骏(浙江大学医学院附属第一医院,浙江杭州310003)〔中图分类号〕TH789 〔文献标识码〕B 〔文章编号〕1002-2376(2009)08-0062-03 〔摘 要〕归纳了百特Accure 床边血液滤过系统常见的一些故障,分析以及处理这些故障的方法,并简单介绍了一些紧急处理的方法。
〔关键词〕床边血液滤过;百特Accure ;维修;紧急处理1 Accura 系统的基本功能Baxter 医疗用品有限公司的Accura 系统可以对患有急性肾功能衰竭症状或者是体液过多的病人进行治疗。
以连续治疗操作的方式实现病人体内毒素排除或排除多余体液的治疗目的。
同时Accura 系统也可以对病人进行血浆置换(TPC )治疗。
另外,Accura 系统可以应用于血液灌注治疗(系统默认不支持,需要另行打开此项功能)。
2 常规Accura 系统描述Accura 系统的管路系统分为三部分:体外管路系统(血液管路)、滤出管路系统和置换液/透析液管路系统。
系统通过利用一次性使用的滤过器,将体外血液管理系统内血液中的毒素排除出去之后,将经过血液滤过处理的干净的血液返还到病人体内。
Accura 系统通过使用两个称重计来精确地测量滤除液和置换液的数量,并且能够精确地平衡滤除液和置换液的质量。
Accura 系统自带抗凝剂注射泵,可在治疗过程中选择连续或者是间断注射抗凝剂。
为了预防在治疗过程中可能出现的各种危险情况,Accura 系统的控制单元都设计为双通道的工作模式(控制通道和安全保护通道)。
3 Accura 系统的常见故障维修以及紧急处理Accura 系统在抢救危重病人,特别是在IC U 等科室中的运用越来越广泛。
因多在急诊抢救中运用,所以对维修时效性要求比较高;又因为机器比较新,所以普遍维修经验不多。
下面对常见一些故障进行讨论并根据维修经验提出相应的解决办法以及一些应急维修处理的技巧。
百特aquarius机常见报警和处置培训课件
置换液袋内没有溶液,滤出 液袋已达到了可允许的最大 重量
Heater cooling down 加热器冷 当加热器面板温度超过43℃
却
3/9/2021
时,百平特衡aq系uari统us机工常作见报停警止和处置
处理
如果不需抗凝,则转至下一 个屏幕;如果需要抗凝,则 安装装有抗凝剂的注射器, 并在程序中设定抗凝率。
No fluid chamber detect
正确插入除气壶,小心安 装在低部的传感器,如果 此操作无效,则关闭加热 器,终止治疗。然后致电 技术服务部门
Pump door 泵的门 3/9/2021
泵的门之一处于打开状态 关闭一个或多个泵的门
百特aquarius机常见报警和处置
显示
原因
Anticoagulannt off 抗凝关闭 抗凝率在程序中被设为零
Heparin sysinge missing 抗凝 抗凝注射器没有放置在抗凝
注射器消失
泵上
Change syringe 更换注射器
安放在抗凝泵上的注射器已 空
Change substitution bag 更换 置换液袋
High access pressure动脉压力高 Low access pressure动脉压力低
• 动脉血液通路夹(包 括动脉和滤器前压力 传感器)关闭或打结
• 患者的血管通路堵塞
• 打开夹子或理顺管路 • 疏通或更换导管
• 血流量不足
• 调节血流量
• 血泵速度太慢或太快 • 提高或降低血泵流速
• 静脉管路断开
• 静脉压力传感器管路 没装好
• 打开夹子,理顺管路
• 疏通或更换导管 • 提高或降低血泵速度 • 连接静脉管路 • 重新装好静脉压力传
博世G5说明文档
第五章 功能详细说明 ..............................................................72
5.1 基本运行参数( B参数 ) .....................................................................72 5.2 中级运行参数( L 参数) .................................................................76 5.3 高级运行参数( H 参数) .................................................................99 5.4 应用扩展参数(E参数) .................................................................. 113
第四章 功能参数一览表 ..........................................................59
4.1 基本运行参数(B参数) ....................................................................59 4.2 中级运行参数(L参数) ....................................................................60 4.3 高级运行参数(H参数) ....................................................................63 4.4 应用扩展参数(E参数) ....................................................................66 4.5 状态监控参数一览表 ..........................................................................67 4.6 保护功能及对策..................................................................................69 4.7 故障记录查询......................................................................................70
XMA5000福光百特智能仪表aa
9 10 11 12 13 14 15 16
XMA5000系列小表端子图
报警 1
10 11 12 13 14 9
报警 1
+ + -
SCR1 fire pulse
4 5 6 7 8
+
+24VDC
SCR2 fire pulse
四线制 变送器
+
信号正
4 6 3 4 15 16
10 11
报警 2
-电源地
二线制 变送器
电阻 RTD
ON SH1
4 3 2 1
电偶 TC
ON SH1
4 3 2 1
跳线器位置示意图 XMA5000系列横竖表(80X160X80mm 160X80X80mm)输入板跳线器位置示意图
ON S1
4 3 2 1
输入信号 跳线器 示意图
电压 V
ON S1
4 3 2 1
电流 mA
ON S1
4 3 2 1
JP6 JP5 JP4
电阻 RTD
JP6 JP5 JP4
电偶 TC
JP6 JP5 JP4
跳线器位置示意图 XMA5000系列72x72小方表输入板跳线器位置示意图
-
4
-
、 96×48 和 48×96 小表输入板跳线设置图
输入信号 JP7
电偶 TC
电阻RTD
电流 mA
电压 V
JP6 1 JP5 JP7 跳线器
报警1 13 14 V or mA or PWM
6 7 3 6
二线 制变 送器
+24VDC
1 2
报警2
A B
输入信号接线图
百特工控数显表故障代码
百特工控数显表故障代码百特工控数显表性价比较高,广泛适用于温度、压力、液位、流量等各种工业参数的测控。
以下是多年来使用、检修仪表的几点经验。
1、一台XMT5020温度显示仪,台上电源,空气开关立即跳闸分析与检修:该仪表内部未设保险丝(见图1),开机后, 10A空气开关立即关断。
查电源输入端电阻为4k左右(正常输入电阻应大于200k),怀疑该仪表开关电源高压侧存在短路,断开TOP222Y,测漏极D(黑表笔)对源极S(红表笔)的电阻为1k左右,远低于正常值64k,更换TOP222Y后,故障排除。
提示:在无示波器和晶体管测试仪的情况下,采用电阻法检修是较好的方法,TOP222Y的正常值如附表(用MF500型万用表Rx 1k挡的测值)。
2、一台XMT51UO RS485温度显示仪,台上电源开关,数码管无显示分析与检修:测仪表输入电阻正常,合上电源开关,测12端电压分别为-5V、+6. 5V、+24V,均正常,但无+5V电压输出。
因+6. 5V电压正常,则D8整流输出+ 7V电压,故障原因显然在于U7(78L05),因为缺+5V电压,导致机内数模转换电路ICL7135CN和信号处理电路AT89C55WD无法工作而出现黑屏。
经更换78L05后,仪表恢复正常。
3、一台XMT5020温度显示仪,始终显示brot,无法正常工作分析与检修:输入信号为pt100,显示brot现象的常见故障为输入信号开路或仪表分度号选择错误。
经仔细检查,发现pt100输出电阻正常,仪表设置亦正常。
经查故障系稳压电源无-5V输出所致(该负压供给电子开关集成块CD40528,因无-5V,该电子开关截止,导致输入信号中断,显示brot),最后细查发现是J2排线中的第3根线根部折断所致。
重焊后,故障排除。
百特550血透机低电导故障的维修
百特550血透机低电导故障的维修
葛香谷
【期刊名称】《医疗装备》
【年(卷),期】2000(013)010
【摘要】@@ 故障现象:血透机在透析过程中经常出现间歇的低电导报警,造成血透机透析旁路,空气进入透析管路,导致透析效率降低.
【总页数】1页(P59)
【作者】葛香谷
【作者单位】东阳市人民医院,浙江东阳,322100
【正文语种】中文
【中图分类】TH789
【相关文献】
1.百特 SPS550血透机温控探头故障检修 [J], 李铭;罗旭华
2.百特SPS550血透机低电导报警4例 [J], 王飞
3.百特 sps-550血透机血泵停转故障速修 3例 [J], 游玉明;裴峰
4.百特SPS-550血透机多脱水故障维修 [J], 魏东
5.百特550血透机血泵故障维修两例 [J], 王伟芳
因版权原因,仅展示原文概要,查看原文内容请购买。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
S
未锁
S
上锁码设定 △ XXXX 开锁码设定 △ 开锁成功 △ 操作失败 工作态
△
已锁
XXXX 阀位上限幅
XXXX 阀位下限幅
XXXX 报警值设置
△
/ 高、低报警选择 △ △
XXXX 输出死区
2.4 z z
2.5
2.6
2.7 z z z z z z 2.8
以保证实际阀位不因前级调节器或 DCS 系统的故障而失控。 输入输出信号 阀位给定:0-10mA/4-20mA/0-5V/1-5V 输入通用。 实际阀位反馈信号输入:0-10mA/4-20mA/0-5V/1-5V 通用。 阀位反馈输出:0-10mA/4-20mA/0-5V/1-5V 可设定。 正转、反转输出信号:3A/600V 双向可控硅控制,容量大,寿命长可驱动各种规格的电动调节阀门。 4 个 DI 输入:只接受干触点信号。 手动状态继电器输出。 单片机智能化设计,全部参数按键可设定,双数显、双光柱显示(竖表) 。 可带 RS485/ RS232 隔离通讯接口。
版本号:V3.3
DFDA5000 智能型带伺服放大器的后备操作器 Reserve Manual Controller With Servo Amplifier
使 用 说 明 书
Operation Instruction
目 录
一、 适用范围…………………………………………………………………………………1 二、 功能特点…………………………………………………………………………………1 三、 技术参数…………………………………………………………………………………2 四、 订货选型…………………………………………………………………………………3 五、 安装接线…………………………………………………………………………………4 六、 面板显示信息说明………………………………………………………………………7 七、 操作总框图………………………………………………………………………………9 八、 参数设定操作详细说明…………………………………………………………………10 九、 常见故障处理……………………………………………………………………………15
三、 技术参数
z z z z z z z z z z z 电源:220VAC 或 24VDC。 阀位给定输入:0~10mA 或 4~20mA 或 0~5V 或 1~5V 通用。 阀位反馈输入:0~10mA 或 4~20mA 或 0~5V 或 1~5V 通用。 阀位控制正反转输出:220VAC/15A 阀位反馈输出:0~10mA 或 4~20mA 或 0~5V 或 1~5V 通用。 手自动状态输出:继电器触点 220VAC/3A 或 24VDC/3A。 报警状态输出:继电器触点 220VAC/3A 或 24VDC/3A。 通讯接口:RS485 或 RS232 输入输出光电隔离。 远程手/自动信号:干触点输入。 远程开阀门信号:干触点输入。 远程关阀门信号:干触点输入。 2
9 10
配电输出 输入接线图
RXD TXD DTR GND 21 22 23 24 17 18
输出接线图
A B
19 20
220VAC
19 20 24VDC
RS232通讯接线图
RS485通讯接线图
电源接线图
备注:1.Modem 和 PRN 接线图同 RS232; 2.以上接线图仅供参考。公司保留对产品升级的权利,如有更改恕不通知,以仪表后壳接线为准。 5
6 7
远程强制手动输入 输入信号接线图
手动状态信号输出
RXD TXD GND
15 16 17
13 14
220VAC
13 14
24VDC
15 16
A B
RS232通讯接线图
电源接线图
RS485通讯接线图
备注:以上接线图仅供参考。公司保留对产品升级的权利,如有更改恕不通知,以仪表后壳接线为准。 说明:DFDA5000 系列 72×72×110mm 输入板跳线器位置示意图
5 6
V OR mA
IN1给定输入
V OR mA
DFDA5000接线图 (96mm×96mm)
3 3 4 IN2阀位反馈输入 7 8 远程强制手动输入
P=+24V
23 24 25 26 27 28 29 30
阀位反馈输出
11 12 13 14 15 16
4 5 6 7 8 9
手动状态 信号输出
相线 正转输出 相线 反转输出
一、 适用范围
DFDA5000 是伺服放大器、手动操作器和后备功能一体化智能产品,接收 0-10mA/4-20mA/0-5V/1-5V 阀位给定信 号,输出正转、反转控制信号。适合于作为 DCS 系统回路调节控制输出和智能调节器控制输出的后备操作器使用。
二、 功能特点
2.1 2.2 2.3 DFDA5000 处在自动工作态时,其功能类似伺服放大器。按阀位给定信号和阀位反馈信号的误差进行调节控制,以确 保实际阀位及时跟踪阀位给定信号,实现自动控制。 DFDA5000 处于手动状态时,其功能类似一个操作器,可通过面板上的Δ键和∇键直接操作正转输出信号和反转输出 信号,即按住Δ键时,输出正转信号,按住∇键时输出反转信号,松开按键后不输出任何控制信号。 实际阀位反馈输出信号 实际阀位反馈输出信号是 DFDA5000 输出给前级的 DCS 系统或前级调节器的信号,其作用有二:一是使 DCS 系统随时监测实际阀位;二是实现 DFDA5000 手动转自动无扰切换使用。 手/自动无扰切换 DFDA5000 自动转手动时,以当时的实际阀位反馈值作为初始值,开始手动调节控制,因此自动转手动是无扰的。 DFDA5000 手动转自动操作 DFDA5000 手动时输出一个手动状态信号给前级的 DCS 系统或调节器, DCS 系统或调节器收到 DFDA5000 的手 动状态信号后即停止 PID 运算,并让其控制输出跟踪阀位反馈信号,DFDA5000 手动转自动后手动状态信号撤消, DCS 系统或前级调节器以当时的输出控制值为初始值恢复 PID 控制。这样 DFDA5000 手动转自动操作也是无扰的。 远程手/自动控制 DFDA5000 提供了远程手动, 远程阀门开和远程阀门关一组控制输入信号, 这组控制输入信号只接受干触点信号, 其功能和面板上的 A/M 键、Δ键和∇键的功能一样。 远程强制手动 DFDA5000 提供了远程强制手动输入信号,该信号只接受干触点信号,通常和前级 DCS 和智能调节器的故障状 态输入信号对接,用于在前级 DCS 和智能调节器发生故障时,DFDA5000 能自动转到手动状态,使阀位保持不变, 1
SV
%
MV
%
SV
%
MV
%
ALARM OPEN CLOSE MAN
外形尺寸(长×高×深) : 80×160×150mm 开孔尺寸(长×高) : 76+0.74×152+1.00mm 76+0.74×152+1.00mm 92+0.87×92+0.87mm 68+0.74×68+0.74 mm 80×160×150 mm 96×96×110mm 72×72×110 mm
XXXX 阀门行程时间 △ △
△
△ △
S
/…/ 给定输入量程设置
S
/…/ 阀位反馈输入量程设置 △
S
/…/ 阀位反馈输出量程设置
△ △
S
△ ~ 通讯地址码 △
S
△ /.../ /../ 通讯波特率
给定输入 反馈输入 输入信号 跳线器 示意图 跳线器位置示意图 给定输入 给定输入 反馈输入 反馈输入 电压V 电流mA 电压V 电流mA
6
六、面板显示信息说明
SV
% %
SV
% %
MV
MV
MAN CLOSE OPEN ALARM
MAN CLOSE OPEN ALARM
MAN CLOSE OPEN ALARM
IN1给定输入
V OR mA 3 4
阀位反馈输出
IN2阀位反馈输入
RS485通讯接线图
24 25 26 RXD TXD GND
DFDA5000接线图 (80mm×160mm)
远程强制手动输入
7 8
RS232通讯接线图
27 28
远程手/自动切换 信号输入
9 10
手动状态信号输出
远程手动增输入
11 12
容
显 示
屏
上 显 示 屏 SV 光 柱 下 显 示 屏 MV 光 柱
操
SET
作 键
A/M
指 示 灯
MAN CLOSE OPEN ALARM
开度减小时灯亮 开度增大时灯亮 报警时灯亮,表示阀位输入信号超限; 灯闪时表示阀位输入信号故障 8
七、操作总框图
A/M 手动工作态 A/M 自动工作态 S
// 上锁级别设定
四、订货选型
型 DFDA 设计序列 输入信号 类 型 输出信号 反馈输入 信号类型 5 5 6 7 8 0 1 5 6 7 8 5 6 7 8 V F SF GV P D 谱 说 明 带伺服放大器的智能后备操作器 开关电源 0-10mA 输入 4-20mA 输入 0-5V 输入 1-5V 输入 可控硅正反转驱动信号输出 继电器正反转驱动信号输出 0-10mA 输入 4-20mA 输入 0-5V 输入 1-5V 输入 0-10mA 输出 4-20mA 输出 0-5V 输出 1-5V 输出 80×160×150mm 双数显竖表 96×96×110mm 双数显方表 72×72×110mm 双数显小方表 80×160×150mm 双光柱双数显竖表 缺省为不带直流电源输出 带 24V 直流电源输出 供电电源 220VAC 供电电源 24VDC 不带通讯接口 RS232 RS232 隔离通讯接口 RS485 RS485 隔离通讯接口 Modbus RS485 隔离通讯接口(Modbus-RTU 协议)