三维立体图集16G101-03第四章梁平法识图
16G101三维图集学习教程(全本)
16建筑三维平法结构识图教程目录第一章:钢筋锚固长度及其相关规范1.1受拉钢筋基本锚固长度L ab ,L abE受拉钢筋锚固长度修正系数·····························1.2混凝土结构的环境类别混凝土保护层的最小厚度(mm )纵向受力钢筋搭接区箍筋构造 ·····························1.3纵向钢筋弯钩与机械锚固形式纵向受拉钢筋綁扎搭接长度L L 、L LE ··························1.4封闭箍筋及拉筋弯钩构造梁并筋等效直径、最小净距梁柱纵筋间距要求螺旋箍筋构造 ·································1.5封闭箍筋及拉筋弯钩构造基础梁箍筋复合方式非接触纵向钢筋搭接构造·····························································第二章:柱平法标准构造详图及三维示意图2.1·······························2.2抗震KZ 纵向钢筋连接构造······························2.3地下室抗震KZ 的纵向钢筋连接构造、地下室抗震KZ 的箍筋加密区范围 ··························2.4抗震框架柱和角柱柱顶纵向钢筋构造·························2.5抗震KZ 中柱顶纵向钢筋构造······························2.6抗震KZ 柱变截面位置纵向钢筋构造···························2.7抗震KZ 、QZ 、LZ 箍筋加密区范围抗震QZ 、LZ 纵向钢筋构造 ······························2.8抗震框架柱和小墙肢箍筋加密区高度选用表·······················2.9非抗震KZ 纵向钢筋连接构造·····························2.10非抗震KZ 边柱和角柱柱顶纵向钢筋构造························2.11非抗震KZ 中柱顶纵向钢筋构造····························2.12非抗震KZ 柱变截面位置纵向钢筋构造·························2.13非抗震KZ 箍筋构造非抗震QZ 、LZ 纵向钢筋构造······························第三章:剪力墙平法标准构造详图及三维示意图3.1剪力墙身水平钢筋构造................................27.. (31)3.3剪力墙身竖向钢筋构造 (32)3.4约束边缘构件YBZ 构造 (35)3.5剪力墙水平钢筋计入约束边缘构件体积配箍率构造做法 (37)3.6构造边缘构件GBZ 、扶壁柱FBZ 、非边缘暗柱AZ 构造剪力墙边缘构件纵向钢筋连接构造剪力墙约束边缘构件纵筋构造 (38)3.8剪力墙 LL /AL BKL 配筋构造 (39)3.9剪力墙BKL 或AL 与LL 重叠时配筋构造··························403.10连梁交叉斜筋配筋LL (JX )连梁集中对角斜筋配筋LL (DX )连梁对角暗撑配筋LL (JC )构造 (42)3.11地下室外墙DWQ 钢筋构造...............................433.12剪力墙洞口补强构造 .. (45)第四章:梁平法标准构造详图及三维示意图 (47)4.2抗震屋面框架梁WKL 纵向钢筋构造 (48)4.3非抗震楼层框架梁KL 纵向钢筋构造 (49)4.4非抗震屋面框架梁WKL 纵向钢筋构造 .........................504.5框架梁水平、竖向加腋构造.. (51)ζa 1.6芯柱XZ 配筋构造矩形箍筋复合方式柱插筋在基础中的锚固3.2墙插筋在基础中的锚固4.1抗震楼层框架梁WKL 纵向钢筋构造4.6KL 、WKL中间支座纵向钢筋构造 (53)4.7抗震框架梁KL、WKL箍筋加密区构造抗震框架梁KL、WKL箍筋加密区构造 (54)4.8梁与方柱斜交或与圆柱相交时箍筋起始位置 (55)4.9非框架梁L配筋构造主次梁斜交箍筋构造 (56)4.10不伸入支座的梁下部纵向钢筋断点位置附加箍筋范围、附加吊筋构造梁侧面纵向构造筋和拉筋 (57)4.11非框架梁L中间支座纵向钢筋构造水平折梁、竖向折梁钢筋构造 (58)4.12纯悬挑梁XL及各类梁的悬挑端配筋构造 (59)4.13KZZ/KZL配筋构造 (51)4.14井字梁JZL配筋构造 (65)第五章:板平法标准构造详图及三维示意图5.1有梁楼盖楼(屋)面板配筋构造 (67)5.2有梁楼盖不等跨板上部贯通纵筋连接构造 (69)5.3单(双)向板配筋示意纵向钢筋非接触搭接构造 (70)5.4悬挑板XB钢筋构造 (71)5.5无支撑板端部封边构造折板配筋构造 (72)5.6无梁楼盖柱上板带ZSB与跨中板带KZB纵向钢筋构造 (73)5.7板带端支座纵向钢筋构造板带悬挑端纵向钢筋构造 (74)5.8柱上板带暗梁钢筋构造 (75)5.9板后浇带HJD钢筋构造墙后浇带HJD钢筋构造梁后浇带HJD钢筋构造 (76)5.10板加腋JY构造局部升降板SJB构造(一) (77)5.11板加腋JY构造局部升降板SJB构造(二) (78)5.12板开洞BD与洞边加强钢筋构造一(洞边无集中荷载) (79)5.13板开洞BD与洞边加强钢筋构造二(洞边无集中荷载) (80)5.14悬挑板阳角放射筋Ces构造 (81)5.15板内纵筋加强带JQD构造板翻边FB构造悬挑板阴角构造 (82)5.16柱帽ZMa、ZMb,ZMc、ZMab构造 (83)5.17抗冲切箍筋Rh构造抗冲切弯起筋Rb构造 (84)第六章:楼梯平法识图规则与标准构造详图及三维示意图6.1AT型楼梯平面注写方式与适用条件 (86)6.2AT型楼梯板配筋构造 (88)6.3BT型楼梯平面注写方式与适用条件 (89)6.4BT型楼梯板配筋构造 (91)6.5CT型楼梯平面注写方式与适用条件 (92)6.6CT型楼梯板配筋构造 (94)6.7DT型楼梯平面注写方式与适用条件 (95)6.8DT型楼梯板配筋构造 (97)6.9ET型楼梯平面注写方式与适用条件 (98)6.10ET型楼梯板配筋构造 (99)6.11FT型楼梯平面注写方式与适用条件 (100)6.12FT型楼梯板配筋构造(A-A) (101)6.13FT型楼梯板配筋构造(B-B) (102)6.14GT型楼梯平面注写方式与适用条件 (103)6.15GT型楼梯板配筋构造(A-A) (104)6.16GT型楼梯板配筋抅造(B-B) (105)6.17HT型楼梯平面注写方式与适用条件. (106)6.18HT型楼梯板配筋构造(A-A) (107)6.19HT型楼梯板配筋构造(B-B) (108)6.20C-C,D-D剖面楼梯平板配筋构造 (109)6.21ATa型楼梯平面注写方式与适用条件 (110)6.22ATa型楼梯板配筋构造 (111)6.23ATb型楼梯平面注写方式与适用条件 (112)6.24ATb型楼梯板配筋构造 (113)6.25ATc型楼梯平面注写方式与适用条件 (114)6.26ATc型楼梯板配筋构造 (116)6.27不同踏步位度推高与高度减小构造 (117)6.28各型楼梯第一跑与基础连接构造 (118)6.29楼梯施工图剖面注写示例(平面图) (119)6.30楼梯施工图剖面注写示例(剖面图) (120)6.31Ata型楼梯施工图剖面注写示例(平面图) (121)6.32Ata型楼梯施工图剖面注写示例(剖面图) (122)6.33Atb型楼梯施工图剖面注写示例(平面图) (123)6.34Atb型楼梯施工图剖面注写示例(剖面围) (124)6.35ATc型楼梯施工图剖面注写示例1(平面图) (125)6.36ATc型楼梯施工图剖面注写示例1(剖面图) (126)6.37ATc型楼梯施工图剖面注写示例2(平面图) (127)6.38ATc型楼梯施工图剖面注写示例2(剖面图) (128)第七章:基础平法标准构造详图及三维示意图任务一:独立基础平法标准构造详图及三维示意图7.1独立基础DJ J、DJ P、BJ J、BJ P底板配筋构造 (130)7.2双柱普通独立基础底部与顶部配筋构造 (131)7.3设置基础梁的双柱普通独立基础配筋构造 (132)7.4独立基础底板配筋长度减短10%构造 (133)7.5单杯口和双杯口独立基础构造 (134)7.6高杯口独立基础杯壁和基础短柱配筋构造 (135)7.7双高杯口独立基础杯壁和基础短柱配筋构造 (136)7.8单柱普通独立深基础短柱配筋构造 (137)7.9双柱普通独立深基础短柱配筋构造 (138)任务二:条形基础平法标准构造详图及三维示意图7.10条形基础底板 TJB J 和 TJB P配筋构造 (139)7.11条形基础底板配筋长度减短10%构造条形基础板底不平构造条形基础无交接底板端部构造 (140)7.12基础梁 JL 纵向钢筋与箍筋构造附加箍筋构造附加(反扣)吊筋构造 (141)7.13基础梁 JL 配置两种箍筋构造 (142)7.14基础梁 JL 竖向加腋钢筋构造 (143)7.15基础梁 JL 端部与外伸部位钢筋构造 (144)7.16基础梁 JL 侧面构造纵筋和拉筋 (145)7.17基础梁 JL 梁底不平和变截面部位钢筋构造 (146)7.18基础梁 JL 与柱结合部侧腋构造 (147)7.19基础次梁 JCL 纵向钢筋与箍筋构造基础次梁 XL 端部外伸部位钢筋构造 (148)7.20基础次梁 JCL 竖向加腋钢筋构造基础次梁 JCL 配置两种箍筋构造 (149)7.21基础次梁 JCL 梁底不平和变截面部位钢筋构造 (150)任务三:筏形基础平法标准构造详图及三维示意图7.22梁板式筏形基础平板 LPB 钢筋构造 (151)7.23梁板式筏形基础平板LPB下部柱向区域与跨中区域钢筋构造 (152)7.24梁板式筏形基础平板 LPB 端部与外伸部位钢筋构造梁板式筏形基础平板 LPB 变截面部位钢筋构造 . (153)7.25平板式筏基柱下板带ZXB与跨中板带 KZB 纵向钢筋构造 (154)7.26平板式筏形基础平板BPB钢筋构造 (156)7.27平板式筏形基础平板(ZXB、KZB、BPB)变截面部位钢筋构造 (158)7.28平板式筏形基础平板(ZXB、KZB、BPB)端部与外伸部位钢筋构造 (159)任务四:桩基础承台平法标准构造详图及三维示意图7.29矩形承台CT J和CT P配筋构造桩顶纵筋在承台内的锚固构造 (160)7.30等边三桩承台CT J配筋构造 (161)7.31等腰三桩承台CT J配筋构造 (162)7.32六边形承台CT J筋构造 ......... (163)7.33墙下单排桩承台梁C TL配筋构造 (165)7.34墙下双排桩承台梁CTL配筋构造` (166)任务五基础相关构造的平法标准构造详图及三维示意图7.35基础联系梁JLL配筋构造 (167)7.36基础底板后浇带HJD构造基础梁后浇带HJD构造 (168)7.37后浇带HJD下抗水压垫层构造后浇带HJD超前止水构造基坑JK构造 (169)7.38上柱墩SZD构造(棱台与棱柱形) (170)7.39下柱墩X ZD构造(倒棱台与倒棱柱形) (171)7.40防水底板JB与各类基础的连接构造 (173)7.41窗井墙CJQ配筋构造 (174)审核校对设计页图集号16G101-1-56-7-混凝土结构的环境类别混凝土保护层的最小厚度审核校对设计页图集号16G101-1-57-8-受拉钢筋基本锚固长度Lab抗震设计时受拉钢筋基本锚固长度labE 钢筋弯折时的弯弧D审核校对设计页图集号16G101-1-58-8-受拉钢筋基本锚固长度La 受拉钢筋基本锚固长度La E审核校对设计页图集号16G101-1-59-8-纵向钢筋弯钩与机械锚固形式纵向受力钢筋搭接区箍筋构造纵向钢筋的连接审核校对设计页图集号16G101-1-60-8-纵向受拉钢筋搭接长度 ll纵向受拉钢筋搭接长度 LL E图集号16G101-1-61封闭箍筋及拉筋构造梁并筋等效直径、最小净距离图集号16G101-1-62梁柱纵筋及间距要求拉筋构造螺旋箍筋构造第二章:柱平法标准构造详图及三维示意图图集号16G101-1-63KZ 纵向钢筋连接构造柱纵向钢筋焊接连接三维示意图非连接区域≥Hn/3搭接长度为非连接区域非连接区域嵌固体部位≥Hn/6≥搭接接头要错开≥0搭接长度为≥Hn/6≥搭接长度为搭接接头要错开≥0.搭接长度为≥Hn/6≥≥Hn/6≥连接区域采用焊接方式两批接头之间错开连接区域采用焊接方式两批接头之间错开≥Hn/6≥Hn/6≥≥Hn/6上柱比下柱多出钢筋伸长锚固到下柱中锚2La E1.2La E非连接区域Hn/6≥500≥hc 搭接长度为L LE 搭接接头要错.3L LE搭接长度为L LE 下柱较大直径钢筋伸入上柱超过上柱非连接区域与上柱较小径钢筋按百分之搭接长度为上柱较大直径钢筋伸入下柱超过下柱非连接区域与下柱较小径钢筋按百分之率搭接长度为非连接区域≥500≥500搭接接头要错L LE L LE下上柱比伸长锚固到固长度为1伸入长度1.2La E嵌固体部位非连接区域非连接区域连接区域采用焊接方式两批接头之间错开非连接区域连接区域采用焊接方式两批接头之间错开Hn/3≥Hn/6≥Hn/6≥Hn/6≥Hn/6楼面楼面柱纵向钢筋机械连接三维示意图柱纵向钢筋绑扎连接三维示意图嵌固体部位非连接区域≥Hn/3非连接区域楼面非连接区域楼面当某层连接区的高度小于纵筋分两批搭接所需要的高度时,应改用机械连接或焊接连接。
16G101第四章梁、板平法识图
第四章:梁平法标准构造详图及三维示意图页图集号16G101-1-841.跨度值 L n 为左跨 L ni 和右跨 L ni+1之较大值,其中i =1,2,3..2.图中h c 为柱截面沿框架方向的高度。
3.梁上部通长钢筋与非贯通钢筋直径相同时,链接位置宜位于跨中L ni /3范围内;梁下部钢筋连接位置宜位于支座L /3范内;且在同一连接区段内钢筋接头面积百分率不宜大于50% 。
4.一级框架梁宜采用机械连接,二、三、四级可采用绑扎搭接或焊接连接。
....ni 楼层框架梁KL 纵向钢筋构造≥L aE 且≥0.5h c +5d搭接长度≥非搭接区≥梁上部第二排钢筋 梁上部第一排钢筋梁下部钢筋注:抗震楼层框架梁 KL 纵向三维钢筋构造示意傅华夏hc梁下部钢筋不能在柱内锚固时,可在节点外搭接。
相邻跨钢筋直径不同时,搭接位梁下部筋在节点外搭接中间层中间节点设计页图集号16G101-1-85纵向钢筋构造abE锚固长度伸入柱内长度5d ,搭接长度≥L LE非搭接区≥1.5h 0梁上部通长筋梁下部纵筋梁上部纵筋1.跨度值 L n 为左跨 L ni 和右跨 L ni+1之较大值,其中i =1,2,3..2.图中h c 为柱截面沿框架方向的高度。
3.梁上部通长钢筋与非贯通钢筋直径相同时,链接位置宜位于跨中L ni /3范围内;梁下部钢筋连接位置宜位于支座L /3内;且在同一连接区段内钢筋接头面积百分率不宜大于50% 。
4.一级框架梁宜采用机械连接,二、三、四级可采用绑扎搭接或焊接连接。
....ni 注:傅华夏廖宜香hc≥1.5h0≥llE 顶层中间节点梁下部筋在节点外搭接(梁下部钢筋不能在柱内锚固时可在节点外搭接。
相邻跨钢筋直径不同时搭接位置位于较小直径一跨)审核校对设计页图集号16G101-1-86框架梁水平、竖向加腋构造1.括号内为非抗震梁纵筋锚固长度2.当梁结构平法施工图中,水平加腋部位的配筋设计未给出时,其梁腋上下部斜纵筋 (仅设置第一排)直径分别同梁内上下纵筋,水平间距不宜大于200;水平加腋部位侧 面纵向构造筋的设置及构造要求同梁内侧纵向构造筋。
零基础学钢筋计算-16G系列钢筋平法工程图文详解
钢筋工程计量----结构各构件的支座关系
梁是板的支座 柱是梁的支座 基础梁是柱的支座
钢筋工程计量----框架梁钢筋设置及构造
梁加腋(边、中支座处)
钢筋工程计量----梁加腋
钢筋工程计量----主次梁交接处吊筋
11G101-3P53柱插筋构造
图2
基础插筋的计算
框架柱钢筋构造图示
-基础插筋
图一
插筋保护层度>5d;hj>laE(la)
插筋保护层度>5d;hj≤laE(la)
图三
柱外侧插筋保护层度≤d;hj>laE(la)
柱外侧插筋保护层度≤d;hj>laE(la)
柱外侧插筋保护层度≤5d;hj≤laE(la)
注: 1.当不同直径的钢筋搭接时,Ll、LlE按直径较小的钢筋计算。 2.在任何情况下Ll不得小于300mm。 3.式中ξl为纵向受拉钢筋搭接长度修正系数,当纵向钢筋搭接接头百分率为表的中间值时,可按内插取值。
抗震
非抗震
LlE=ξlLaE
Ll=ξlLa
纵向受拉钢筋搭接长度修正系数ξl
纵向钢筋搭接接头面积百分率(%)
16G101-2 混凝土结构施工图平面整体表示方法制图规则和构造详图 (现浇混凝土板式楼梯)
16G101-3 混凝土结构施工图平面整体表示方法制图规则和构造详图 (独立基础、条型基础、筏型基础及桩基承台)
三a
严寒和寒冷地区冬季水位变动区环境; 受除冰盐影响环境 ; 海风环境。
三b
盐渍土环境 ; 受除冰盐作用环境 ; 海岸环境。
四
海水环境。
五
受人为或自然的侵蚀性物质影响的环境。
16G101图集承台梁的平法识图
承台梁的平法识图
承台梁的平法识图
承台梁的平法识图
集中标注
承台梁 平面注写
原位标注
16G101-3 P49-50
承台梁编写:CTL
必注内容
截面尺寸:b x h
配筋:箍筋及纵筋
承台梁底面标高
选注内容 必要文字注解
附加箍筋或(反扣)吊筋
修正内容
承台梁的平法识图
二、承台梁的识图
承台梁的平法识图
承台梁的平法识图
目录
CONTENTS
承台梁的平面注写方式 承台梁的识图
承台梁的平法识图
集中标注
承台梁 平面注写
原位标注
Hale Waihona Puke 16G101-3 P49-50承台梁编写:CTL
必注内容
截面尺寸:b x h
配筋
承台梁底面标高
选注内容 必要文字注解
附加箍筋或(反扣)吊筋
修正内容
承台梁的平法识图
16G101-3 P46
4章、梁识图(16G101)
通长筋(小直径)
llE
llE
llE
llE
(用于梁上部贯通钢筋由不同直径钢筋搭接时)
架立筋
架立筋
150
150
150
150
(用于梁上有架立筋时,架立筋与非贯通钢筋搭接)
ln/3
ln/3
ln/3
ln/4筋弯钩段内侧 且≥0.4labE
≥labE且≥0.5hc+5d ≥labE且≥0.5hc+5d
50 加密区
50 加密区
50 加密区
加密区:抗震等级为一级:≥2.0hb且≥500 抗震等级为二-四级:≥1.5hb且≥500
框架梁KL,WKL箍筋加密区范围(一) (弧形梁洽梁中心线展开,箍筋间距 沿凸面线量度。hb为梁截面高度)
箍筋加密区
梁上部非 梁上部贯 梁下部纵筋 贯通纵筋 通纵筋
箍筋加密区
锚 固 长 度 ≥0 . 4 L abE
15d
50
Δh Δh
50
梁上部纵筋
Δh/(hc-50)≤1/6 hc 时,纵筋可连续布置
梁下部纵筋
5
KL 中间支座纵向钢筋构造 (节点④~⑥)
laE
hc
2
WKL中间支座纵向钢筋构造 (节点①~③)
弯 折 长 度L aE
锚 固 长 度L aE 梁上部纵筋 梁下部纵筋
通长筋 搭接
≥L aE且
(小 直 径) 长 度1 5 0 ≥0 . 5 h c+ 5 d
≥0.5hc+5d ≥labE hc
顶层端支座梁下部钢筋直锚
梁上部通长筋 锚固长度伸 入柱内长度 ≥0 . 5 h c+ 5 d , ≥L aE
梁下部纵筋
16G101-03第四章梁平法识图
审核 郭仁俊 校对 廖宜香 设计 傅华夏 页
-55-
15d 15d
设计按铰接时:ln1/5
充分利用钢筋抗拉强度时:ln1/3
设计按铰接时:≥0.35lab
ln/3 (通长筋)
充分利用钢筋抗拉强度时:≥0.6lab 150 架立筋 150 50
50
ln/3
ln/3
(通长筋)
50
150 架立筋 150
注: 1.括 号 内 为 非 抗 震 梁 纵 筋 锚 固 长 度。 2.当 梁 结 构 平 法 施 工 图 中 , 水 平 加 腋 部 位 的 配 筋 设 计 未 给 出 时 , 其 梁 腋 上 下 部 斜 纵 筋 ( 仅 设 置 第 一 排 ) 直 径 分 别 同 梁 内 上 下 纵 筋 , 水 平 间 距 不 宜 大 于2 0 0;水 平 加 腋 部 位 侧 面 纵向构造筋的设置及构造要求同梁内侧纵向构造筋。 3 .本 图 中 框 架 梁 竖 向 加 腋 构 造 适 用 于 加 腋 部 分 参 与 框 架 梁 计 算 。
弯 折 长 度L aE
锚 固 长 度L aE 梁上部纵筋 梁下部纵筋
Δh 15d Δh
laE ≥0.4labE (可直锚)
hc
锚 固 长 度 ≥0 . 4 L abE
(可直锚)
弯 锚 长度15 d 锚 固 长 度L aE
Δh/(hc-50)>1/6时
4
当支座两边梁宽不同或错开布置时,将无法 直通的纵筋弯锚入柱内;或当支座两边纵筋 梁上部纵筋 根数不同时,可将多出的纵筋弯锚入柱内
顶层端支座梁下部钢筋直锚
梁上部通长筋 锚固长度伸 入柱内长度 ≥0 . 5 h c+ 5 d , ≥L aE
梁下部纵筋
16G101钢筋教程讲义-筏型基础平法识图及钢筋计算
梁板式筏形基础的平法表示
梁板式筏形基础的平法表示
梁板式筏形基础的平法表示
配筋
一种箍筋间距时,级别、直径、间距、肢数 基础梁箍筋
两种箍筋间距时,/分隔,第一种根数及间距
基础梁的底部、顶部 及侧面纵向钢筋
底部(B) 顶部(T) 侧面(G/N)
16G101-3 P31
梁板式筏形基础的平法表示
集中标注
基础主梁的钢筋构造
定额钢筋混凝土工程钢筋工程量计算规则
基础主梁的钢筋构造
1、1、底部、顶部贯通纵筋的搭接和端头支座锚固
16G101-3 P81
基础主梁的钢筋构造
第九节 基础主梁的钢筋构造(二)
目录
一、基础主梁的纵向钢筋构造 二、基础主梁的箍筋构造 三、基础主梁的特殊构造 四、基础主梁侧腋构造
16G101平法钢筋识图算量 详细教程
第四章 筏形基础平法识图及钢筋计算
第一节 筏形基础的分类
目录
一、筏形基础的分类 二、梁板式筏形基础的组成构件 三、平板式筏形基础的组成构件
筏形基础的分类
一、筏形基础的分类
梁板式筏形基础
筏形基础
平板式筏形基础
柱下和跨中板带进行表达 基础平板进行表达
16G101-3 P30、38
筏形基础的分类
二、梁板式筏形基础的组成构件
梁板式 筏形基础
基础主梁(柱下) 基础次梁 梁板筏基础平板
16G101-3 P30
筏形基础的分类
基础平板 基础次梁
8跨有外伸
基础主梁(柱下) 2跨有外伸
筏形基础的分类
三、平板式筏形基础的组成构件
平板式 筏形基础
板带式
柱下板带 跨中板带
平板式筏基础平板
16G101(三维立体)梁平法图集
第四章:梁平法标准构造详图及三维示意图页图集号16G101-1-841.跨度值 L n 为左跨 L ni 和右跨 L ni+1之较大值,其中i =1,2,3..2.图中h c 为柱截面沿框架方向的高度。
3.梁上部通长钢筋与非贯通钢筋直径相同时,链接位置宜位于跨中L ni /3范围内;梁下部钢筋连接位置宜位于支座L /3范内;且在同一连接区段内钢筋接头面积百分率不宜大于50% 。
4.一级框架梁宜采用机械连接,二、三、四级可采用绑扎搭接或焊接连接。
....ni 楼层框架梁KL 纵向钢筋构造≥L aE 且≥0.5h c +5d搭接长度≥非搭接区≥梁上部第二排钢筋 梁上部第一排钢筋梁下部钢筋注:抗震楼层框架梁 KL 纵向三维钢筋构造示意hc梁下部钢筋不能在柱内锚固时,可在节点外搭接。
相邻跨钢筋直径不同时,搭接位梁下部筋在节点外搭接中间层中间节点设计页图集号16G101-1-85纵向钢筋构造abE锚固长度伸入柱内长度5d ,搭接长度≥L LE非搭接区≥1.5h 0梁上部通长筋梁下部纵筋梁上部纵筋1.跨度值 L n 为左跨 L ni 和右跨 L ni+1之较大值,其中i =1,2,3..2.图中h c 为柱截面沿框架方向的高度。
3.梁上部通长钢筋与非贯通钢筋直径相同时,链接位置宜位于跨中L ni /3范围内;梁下部钢筋连接位置宜位于支座L /3内;且在同一连接区段内钢筋接头面积百分率不宜大于50% 。
4.一级框架梁宜采用机械连接,二、三、四级可采用绑扎搭接或焊接连接。
....ni 注:hc≥1.5h0≥llE 顶层中间节点梁下部筋在节点外搭接(梁下部钢筋不能在柱内锚固时可在节点外搭接。
相邻跨钢筋直径不同时搭接位置位于较小直径一跨)箍筋加密区5050箍筋加密区箍筋加密区c1c3c1c3c1c3c 2h bc 2c 2≥la E ≥l aE 11≥l aE≥l aE≥l a E图中c3取值:抗震等级为一级:≥2.0hb 且≥500抗震等级为二~四级:≥1.5hb 且≥500柱框架梁水平加腋构造审核校对设计页图集号16G101-1-86柱锚固长度≥L aE箍筋箍筋加密区梁上部纵筋加腋筋伸入梁内≥L aE中部构造筋梁下部纵筋框架梁水平、竖向加腋构造注:1.括号内为非抗震梁纵筋锚固长度 2.当梁结构平法施工图中,水平加腋部位的配筋设计未给出时,其梁腋上下部斜纵筋 (仅设置第一排)直径分别同梁内上下纵筋,水平间距不宜大于200;水平加腋部位侧 面纵向构造筋的设置及构造要求同梁内侧纵向构造筋。
16G101三维图集第四章梁平法识图
弯锚长 度 15d
伸至梁上部纵筋 弯钩段内侧或柱 外侧纵筋内侧, 且≥ 0. 4L abE
架力筋
通长筋
搭接长度 ≥ LaE 且
≥ 0. 5h c +5d
搭接 长度 L LE
通长筋
搭接
( 小直径) 长度 150
梁箍筋
≥0.5hc+5d ≥labE
≥0.5hc+5d ≥labE hc
端支座直锚
锚固长度伸入柱内长 度≥ 0 . 5h c + 5d , ≥ LaE 锚固长度伸入柱内长 度≥ 0 . 5h c + 5d , ≥ LaE
ln/4
通长筋
ln/4
通长筋
4
15d 5d 1
伸至梁上部纵筋弯钩段内侧 且≥0.4labE
≥labE且≥0.5hc+5d ≥labE且≥0.5hc+5d
≥labE且≥0.5hc+5d ≥labE且≥0.5hc+5d
hc
ln1
hc
ln2
hc
抗震屋面框架梁 WK纵L 向钢筋构造
弯锚长 度 15d
伸至梁上部纵筋 弯钩段内侧或柱 外侧纵筋内侧, 且≥ 0 . 4L abE
梁上 部纵筋
搭接长 度≥ L LE 非搭接区≥ 1 . 5h 0
注:1. 跨度值 Ln 为左跨 L ni 和右跨 Lni+1 之较大值,其中 i = 1,2,3.. .... 2. 图中 hc为柱截面沿框架方向的高度。
3. 梁上部通 长钢筋与非贯通钢筋直径相同时,链接位置宜位于跨中
L ni /3 范 围内;梁下部钢筋连接位置宜位于支座
ln/3
通长筋
ln/4
ln/3
16G101三维图集学习教程(全本)_1-50
16建筑三维平法结构识图教程序各位尊敬的读者朋友们,感谢大家选择《16建筑三维平法结构识图教程》,建筑工程中建筑结构识图和建筑钢筋工程算量是重要的专业能力。
无论是在施工、造价,还是工程管理,我们都离不开对目录第一章:钢筋锚固长度及其相关规范1.1受拉钢筋基本锚固长度L ab ,L abE受拉钢筋锚固长度修正系数·····························1.2混凝土结构的环境类别混凝土保护层的最小厚度(mm )纵向受力钢筋搭接区箍筋构造 ·····························1.3纵向钢筋弯钩与机械锚固形式纵向受拉钢筋綁扎搭接长度L L 、L LE ··························1.4封闭箍筋及拉筋弯钩构造梁并筋等效直径、最小净距梁柱纵筋间距要求螺旋箍筋构造 ·································1.5封闭箍筋及拉筋弯钩构造基础梁箍筋复合方式非接触纵向钢筋搭接构造·····························································第二章:柱平法标准构造详图及三维示意图2.1·······························2.2抗震KZ 纵向钢筋连接构造······························2.3地下室抗震KZ 的纵向钢筋连接构造、地下室抗震KZ 的箍筋加密区范围 ··························2.4抗震框架柱和角柱柱顶纵向钢筋构造·························2.5抗震KZ 中柱顶纵向钢筋构造······························2.6抗震KZ 柱变截面位置纵向钢筋构造···························2.7抗震KZ 、QZ 、LZ 箍筋加密区范围抗震QZ 、LZ 纵向钢筋构造 ······························2.8抗震框架柱和小墙肢箍筋加密区高度选用表·······················2.9非抗震KZ 纵向钢筋连接构造·····························2.10非抗震KZ 边柱和角柱柱顶纵向钢筋构造························2.11非抗震KZ 中柱顶纵向钢筋构造····························2.12非抗震KZ 柱变截面位置纵向钢筋构造·························2.13非抗震KZ 箍筋构造非抗震QZ 、LZ 纵向钢筋构造······························第三章:剪力墙平法标准构造详图及三维示意图3.1剪力墙身水平钢筋构造................................27.. (31)3.3剪力墙身竖向钢筋构造 (32)3.4约束边缘构件YBZ 构造 (35)3.5剪力墙水平钢筋计入约束边缘构件体积配箍率构造做法 (37)3.6构造边缘构件GBZ 、扶壁柱FBZ 、非边缘暗柱AZ 构造剪力墙边缘构件纵向钢筋连接构造剪力墙约束边缘构件纵筋构造 (38)3.8剪力墙 LL /AL BKL 配筋构造 (39)3.9剪力墙BKL 或AL 与LL 重叠时配筋构造··························403.10连梁交叉斜筋配筋LL (JX )连梁集中对角斜筋配筋LL (DX )连梁对角暗撑配筋LL (JC )构造 (42)3.11地下室外墙DWQ 钢筋构造...............................433.12剪力墙洞口补强构造 .. (45)第四章:梁平法标准构造详图及三维示意图 (47)4.2抗震屋面框架梁WKL 纵向钢筋构造 (48)4.3非抗震楼层框架梁KL 纵向钢筋构造 (49)4.4非抗震屋面框架梁WKL 纵向钢筋构造 .........................504.5框架梁水平、竖向加腋构造.. (51)ζa 1.6芯柱XZ 配筋构造矩形箍筋复合方式柱插筋在基础中的锚固3.2墙插筋在基础中的锚固4.1抗震楼层框架梁WKL纵向钢筋构造4.6KL 、WKL中间支座纵向钢筋构造 (53)4.7抗震框架梁KL、WKL箍筋加密区构造抗震框架梁KL、WKL箍筋加密区构造 (54)4.8梁与方柱斜交或与圆柱相交时箍筋起始位置 (55)4.9非框架梁L配筋构造主次梁斜交箍筋构造 (56)4.10不伸入支座的梁下部纵向钢筋断点位置附加箍筋范围、附加吊筋构造梁侧面纵向构造筋和拉筋 (57)4.11非框架梁L中间支座纵向钢筋构造水平折梁、竖向折梁钢筋构造 (58)4.12纯悬挑梁XL及各类梁的悬挑端配筋构造 (59)4.13KZZ/KZL配筋构造 (51)4.14井字梁JZL配筋构造 (65)第五章:板平法标准构造详图及三维示意图5.1有梁楼盖楼(屋)面板配筋构造 (67)5.2有梁楼盖不等跨板上部贯通纵筋连接构造 (69)5.3单(双)向板配筋示意纵向钢筋非接触搭接构造 (70)5.4悬挑板XB钢筋构造 (71)5.5无支撑板端部封边构造折板配筋构造 (72)5.6无梁楼盖柱上板带ZSB与跨中板带KZB纵向钢筋构造 (73)5.7板带端支座纵向钢筋构造板带悬挑端纵向钢筋构造 (74)5.8柱上板带暗梁钢筋构造 (75)5.9板后浇带HJD钢筋构造墙后浇带HJD钢筋构造梁后浇带HJD钢筋构造 (76)5.10板加腋JY构造局部升降板SJB构造(一) (77)5.11板加腋JY构造局部升降板SJB构造(二) (78)5.12板开洞BD与洞边加强钢筋构造一(洞边无集中荷载) (79)5.13板开洞BD与洞边加强钢筋构造二(洞边无集中荷载) (80)5.14悬挑板阳角放射筋Ces构造 (81)5.15板内纵筋加强带JQD构造板翻边FB构造悬挑板阴角构造 (82)5.16柱帽ZMa、ZMb,ZMc、ZMab构造 (83)5.17抗冲切箍筋Rh构造抗冲切弯起筋Rb构造 (84)第六章:楼梯平法识图规则与标准构造详图及三维示意图6.1AT型楼梯平面注写方式与适用条件 (86)6.2AT型楼梯板配筋构造 (88)6.3BT型楼梯平面注写方式与适用条件 (89)6.4BT型楼梯板配筋构造 (91)6.5CT型楼梯平面注写方式与适用条件 (92)6.6CT型楼梯板配筋构造 (94)6.7DT型楼梯平面注写方式与适用条件 (95)6.8DT型楼梯板配筋构造 (97)6.9ET型楼梯平面注写方式与适用条件 (98)6.10ET型楼梯板配筋构造 (99)6.11FT型楼梯平面注写方式与适用条件 (100)6.12FT型楼梯板配筋构造(A-A) (101)6.13FT型楼梯板配筋构造(B-B) (102)6.14GT型楼梯平面注写方式与适用条件 (103)6.15GT型楼梯板配筋构造(A-A) (104)6.16GT型楼梯板配筋抅造(B-B) (105)6.17HT型楼梯平面注写方式与适用条件. (106)6.18HT型楼梯板配筋构造(A-A) (107)6.19HT型楼梯板配筋构造(B-B) (108)6.20C-C,D-D剖面楼梯平板配筋构造 (109)6.21ATa型楼梯平面注写方式与适用条件 (110)6.22ATa型楼梯板配筋构造 (111)6.23ATb 型楼梯平面注写方式与适用条件 (112)6.24ATb 型楼梯板配筋构造...............................1136.25ATc 型楼梯平面注写方式与适用条件. (114)6.26ATc 型楼梯板配筋构造 (116)6.27不同踏步位度推高与高度减小构造 (117)6.28各型楼梯第一跑与基础连接构造 (118)6.29楼梯施工图剖面注写示例(平面图) (119)6.30楼梯施工图剖面注写示例(剖面图) (120)6.31 Ata 型楼梯施工图剖面注写示例(平面图) (121)6.32 Ata 型楼梯施工图剖面注写示例(剖面图) (122)6.33 Atb 型楼梯施工图剖面注写示例(平面图) (123)6.34 Atb 型楼梯施工图剖面注写示例(剖面围) (124)6.35 ATc 型楼梯施工图剖面注写示例1(平面图) (125)6.36 ATc 型楼梯施工图剖面注写示例1(剖面图) (126)6.37 ATc 型楼梯施工图剖面注写示例2(平面图) (127)6.38 ATc 型楼梯施工图剖面注写示例2(剖面图) (128)第七章:基础平法标准构造详图及三维示意图任务一:独立基础平法标准构造详图及三维示意图7.1独立基础DJ J 、DJ P 、BJ J 、BJ P 底板配筋构造 (130)7.2双柱普通独立基础底部与顶部配筋构造 (131)7.3设置基础梁的双柱普通独立基础配筋构造.......................1327.4独立基础底板配筋长度减短10%构造.........................1337.5单杯口和双杯口独立基础构造. (134)7.6高杯口独立基础杯壁和基础短柱配筋构造 (135)7.7双高杯口独立基础杯壁和基础短柱配筋构造......................136独立深基础短柱配筋构造.. (137)7.9双柱普通独立深基础短柱配筋构造··························138任务二:条形基础平法标准构造详图及三维示意图7.10条形基础底板 TJB J 和 TJB P 配筋构造························1397.11条形基础底板配筋长度减短10%构造条形基础板底不平构造条形基础无交接底板端部构造 (140)7.12基础梁 JL 纵向钢筋与箍筋构造附加箍筋构造附加(反扣)吊筋构造 (141)7.13基础梁 JL 配置两种箍筋构造 (142)7.14基础梁 JL 竖向加腋钢筋构造 (143)7.15基础梁 JL 端部与外伸部位钢筋构造 (144)7.16基础梁 JL 侧面构造纵筋和拉筋 (145)7.17基础梁 JL 梁底不平和变截面部位钢筋构造 (146)7.18基础梁 JL 与柱结合部侧腋构造 (147)7.19基础次梁 JCL 纵向钢筋与箍筋构造基础次梁 XL 端部外伸部位钢筋构造 (148)7.20基础次梁 JCL 竖向加腋钢筋构造基础次梁 JCL 配置两种箍筋构造 (149)7.21基础次梁 JCL 梁底不平和变截面部位钢筋构造····················150任务三:筏形基础平法标准构造详图及三维示意图7.22梁板式筏形基础平板 LPB 钢筋构造 (151)7.23梁板式筏形基础平板LPB 下部柱向区域与跨中区域钢筋构造 (152)7.24梁板式筏形基础平板 LPB 端部与外伸部位钢筋构造梁板式筏形基础平板 LPB 变截面部位钢筋构造 . (153)7.25平板式筏基柱下板带ZXB 与跨中板带 KZB 纵向钢筋构造 (154)7.26平板式筏形基础平板BPB 钢筋构造 (156)7.27平板式筏形基础平板(ZXB 、KZB 、BPB )变截面部位钢筋构造 (158)7.28平板式筏形基础平板(ZXB 、KZB 、BPB )端部与外伸部位钢筋构造 (159)7.8单柱普通任务四:桩基础承台平法标准构造详图及三维示意图7.29矩形承台CT J和CT P配筋构造桩顶纵筋在承台内的锚固构造 (160)7.30等边三桩承台CT J配筋构造 (161)7.31等腰三桩承台CT J配筋构造 (162)7.32六边形承台CT J筋构造 ......... (163)7.33墙下单排桩承台梁C TL配筋构造 (165)7.34墙下双排桩承台梁CTL配筋构造` (166)任务五基础相关构造的平法标准构造详图及三维示意图7.35基础联系梁JLL配筋构造 (167)7.36基础底板后浇带HJD构造基础梁后浇带HJD构造 (168)7.37后浇带HJD下抗水压垫层构造后浇带HJD超前止水构造基坑JK构造 (169)7.38上柱墩SZD构造(棱台与棱柱形) (170)7.39下柱墩X ZD构造(倒棱台与倒棱柱形) (171)7.40防水底板JB与各类基础的连接构造 (173)7.41窗井墙CJQ配筋构造 (174)第一章:钢筋锚固长度及其相关规范审核校对设计页图集号16G101-1-56-7-混凝土结构的环境类别混凝土保护层的最小厚度审核校对设计页图集号16G101-1-57-8-受拉钢筋基本锚固长度Lab抗震设计时受拉钢筋基本锚固长度labE 钢筋弯折时的弯弧D图集号16G101-1-58受拉钢筋基本锚固长度La受拉钢筋基本锚固长度La E图集号16G101-1-59纵向钢筋弯钩与机械锚固形式纵向受力钢筋搭接区箍筋构造纵向钢筋的连接纵向受拉钢筋搭接长度 ll图集号16G101-1-60纵向受拉钢筋搭接长度 LL E图集号16G101-1-61图集号16G101-1-62封闭箍筋及拉筋构造梁并筋等效直径、最小净距离梁柱纵筋及间距要求拉筋构造螺旋箍筋构造第二章:柱平法标准构造详图及三维示意图图集号16G101-1-63KZ 纵向钢筋连接构造柱纵向钢筋焊接连接三维示意图非连接区域≥Hn/3搭接长度为非连接区域非连接区域嵌固体部位≥Hn/6≥搭接接头要错开≥0搭接长度为≥Hn/6≥搭接长度为搭接接头要错开≥0.搭接长度为≥Hn/6≥≥Hn/6≥连接区域采用焊接方式两批接头之间错开连接区域采用焊接方式两批接头之间错开≥Hn/6≥Hn/6≥≥Hn/6上柱比下柱多出钢筋伸长锚固到下柱中锚2La E1.2La E非连接区域Hn/6≥500≥hc 搭接长度为L LE 搭接接头要错.3L LE搭接长度为L LE 下柱较大直径钢筋伸入上柱超过上柱非连接区域与上柱较小径钢筋按百分之搭接长度为上柱较大直径钢筋伸入下柱超过下柱非连接区域与下柱较小径钢筋按百分之率搭接长度为非连接区域≥500≥500搭接接头要错L LE L LE下上柱比伸长锚固到固长度为1伸入长度1.2La E嵌固体部位非连接区域非连接区域连接区域采用焊接方式两批接头之间错开非连接区域连接区域采用焊接方式两批接头之间错开Hn/3≥Hn/6≥Hn/6≥Hn/6≥Hn/6楼面楼面柱纵向钢筋机械连接三维示意图柱纵向钢筋绑扎连接三维示意图嵌固体部位非连接区域≥Hn/3非连接区域楼面非连接区域楼面当某层连接区的高度小于纵筋分两批搭接所需要的高度时,应改用机械连接或焊接连接。
16G101图集承台梁的平法识图PPT
目录
CONTENTS
承台梁的平面注写方式 承台梁的识图
承台梁的平法识图
集中标注
承台梁 平面注写
原位标注
16G101-3 P49-50
承台梁编写:CTL
必注内容
截面尺寸:b x h
配筋
承台梁底面标高
选注内容 必要文字注解
附加箍筋或(反扣)吊筋
修正内容
承台梁的平法识图
16G101-3 P46
承台梁的平法识图
承台梁的平法识图
承台梁的平法识图
集中标注
承台梁 平面注写
原位标注
16G101-3 P49-50
承台梁编写:CTL
必注内容
截面尺寸:b x h
配筋:箍筋及纵筋
承台梁底面标高
选注内容 必要文字注解
附加箍二、承台梁的识图
承台梁的平法识图
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
第四章:梁平法标准构造详图及三维示意图页图集号16G101-1-841.跨度值 L n 为左跨 L ni 和右跨 L ni+1之较大值,其中i =1,2,3..2.图中h c 为柱截面沿框架方向的高度。
3.梁上部通长钢筋与非贯通钢筋直径相同时,链接位置宜位于跨中L ni /3范围内;梁下部钢筋连接位置宜位于支座L /3范内;且在同一连接区段内钢筋接头面积百分率不宜大于50% 。
4.一级框架梁宜采用机械连接,二、三、四级可采用绑扎搭接或焊接连接。
....ni 楼层框架梁KL 纵向钢筋构造≥L aE 且≥0.5h c +5d搭接长度≥非搭接区≥梁上部第二排钢筋 梁上部第一排钢筋梁下部钢筋注:抗震楼层框架梁 KL 纵向三维钢筋构造示意hc梁下部钢筋不能在柱内锚固时,可在节点外搭接。
相邻跨钢筋直径不同时,搭接位梁下部筋在节点外搭接中间层中间节点BIM)、装配式建造、智慧建造、精益建造设计页图集号16G101-1-85纵向钢筋构造abE锚固长度伸入柱内长度5d ,搭接长度≥L LE非搭接区≥1.5h 0梁上部通长筋梁下部纵筋梁上部纵筋1.跨度值 L n 为左跨 L ni 和右跨 L ni+1之较大值,其中i =1,2,3..2.图中h c 为柱截面沿框架方向的高度。
3.梁上部通长钢筋与非贯通钢筋直径相同时,链接位置宜位于跨中L ni /3范围内;梁下部钢筋连接位置宜位于支座L /3内;且在同一连接区段内钢筋接头面积百分率不宜大于50% 。
4.一级框架梁宜采用机械连接,二、三、四级可采用绑扎搭接或焊接连接。
....ni 注:hc≥1.5h0≥llE 顶层中间节点梁下部筋在节点外搭接(梁下部钢筋不能在柱内锚固时可在节点外搭接。
相邻跨钢筋直径不同时搭接位置位于较小直径一跨) 数字建造(BIM)、装配式建造、智慧建造、精益建造审核校对设计页图集号16G101-1-86框架梁水平、竖向加腋构造1.括号内为非抗震梁纵筋锚固长度2.当梁结构平法施工图中,水平加腋部位的配筋设计未给出时,其梁腋上下部斜纵筋 (仅设置第一排)直径分别同梁内上下纵筋,水平间距不宜大于200;水平加腋部位侧 面纵向构造筋的设置及构造要求同梁内侧纵向构造筋。
3.本图中框架梁竖向加腋构造适用于加腋部分参与框架梁计算。
⼤建筑⽹-数字建造(BIM)、装配式建造、智慧建造、精益建造审核校对设计页图集号16G101-1-86框架梁水平、竖向加腋构造注:1.括号内为非抗震梁纵筋锚固长度 2.当梁结构平法施工图中,水平加腋部位的配筋设计未给出时,其梁腋上下部斜纵筋 (仅设置第一排)直径分别同梁内上下纵筋,水平间距不宜大于200;水平加腋部位侧面 纵向构造筋的设置及构造要求同梁内侧纵向构造筋。
3.本图中框架梁竖向加腋构造适用于加腋部分参与框架梁计算。
⼤建筑⽹-数字建造(BIM)、装配式建造、智慧建造、精益建造当支座两边梁宽不同或错开布置时,将无法或当支座两边纵筋(可直锚)(可直锚)审核页图集号16G101-1-87.4L abE弯锚长度 L aE梁上部纵筋梁下部纵筋梁上部纵筋弯锚长度15d梁下部纵筋弯锚长度15d弯锚长度15d 梁上部纵筋梁下部纵筋梁下部纵筋梁上部纵筋中间支座纵向钢筋构造锚固长度L aE 锚固长度≥0.4L abE 弯折长度L aE 锚固长度L aE锚固长度≥0.4L abE锚固长度≥0.4L abEΔh/(hc-50、装配式建造、智慧建造、精益建造校对设计页图集号16G101-1-88梁箍筋构造此端箍筋构造可不设加密区梁端箍筋规格及数量由设计确定次梁(边梁)主梁悬挑端次梁主梁梁上部纵筋梁下部纵筋箍筋 ⼤建筑⽹-数字建造(BIM)、装配式建造、智慧建造、精益建造附加箍筋范围附加吊筋构造附加箍筋范围内梁正常箍筋或加密区箍筋照设附加箍筋配筋值由设计标注梁箍筋构造图集号16G101-1-88-55-审核设计页图集号18G101-1-88或与圆柱相交时箍筋起始位置梁在柱内的箍筋在现场可用两个半套箍搭接或焊接)梁箍筋构造 数字建造(BIM)、装配式建造、智慧建造、精益建造审核校对设计页图集号16G101-1-89非框架梁 L Lg 配筋构造12d1505015d12d12d带肋钢筋12d 505050150150150ln/3ln/3ln/3ln/1ln/2(通长筋)架立筋(通长筋) 架立筋设计按铰接时:ln1/5充分利用钢筋抗拉强度时:ln1/3设计按铰接时:≥0.35lab 充分利用钢筋抗拉强度时:≥0.6lab 15d2289图1非框架梁L 配筋构造(梁上部通常筋连接要求见注3)光圆钢筋15d带肋钢筋12d 光圆钢筋15d箍筋梁上部第一排非贯通纵筋通长筋梁上部第二排非贯通纵筋底部受力筋侧面抗扭钢筋锚固构造要求同梁下部纵向受力钢筋梁下部纵向受力钢梁下部纵向受力钢筋梁上部第二排非贯通钢筋梁上部纵向贯通钢筋图集号16G101-1-901.当hw ≥450mm 时 ,在梁的两个侧面应沿高度配置纵向构造钢筋;纵向构造钢筋间距a ≤200mm 。
2.当梁侧面配有直径不小于构造纵筋的受扭纵筋时,受扭钢筋可以代替构造钢筋。
3.梁侧面构造纵筋的搭接与锚固长度可取15d 梁侧面受扭纵筋的搭接长度为L LE 或L L,其锚固长度为或锚固方式同框架梁下部纵筋。
4.当梁宽≥350mm 时,拉筋直径为6mm;梁宽≥350mm 时,拉筋直径为8mm.拉筋间距为非加密区箍筋间距的2倍。
当设L LE L L,不伸入支座的梁下部纵向钢筋断点梁侧面纵向构造和拉筋位置注:不伸入支座的梁下部纵向钢筋断点位置(本构造详图不适用于框支梁、框架扁梁;伸入支座的梁下部纵向钢筋锚固构造见本图集)ln1 ln2ln30.1ln1 0.1ln10.1ln20.1ln20.1ln3伸入支座的钢筋伸入支座的钢筋伸入支座的钢筋不伸入支座的钢筋不伸入支座的钢筋不伸入支座的钢筋梁侧面纵向构造筋和拉筋侧面纵向构造筋h wba a a a侧面纵向构造筋h wbaaa侧面纵向构造筋ah wba a 不伸入支座的钢筋梁上部贯通纵筋梁下部纵筋不伸入支座的钢筋箍筋伸入支座的钢筋0.1L n10.1L n10.1L n20.1L n20.1L n3锚固长度≥0.6Lab锚固长度≥L aE (L a )弯锚长度≥20d10dL aE (L a )锚固长度L aE (L a )附加纵筋梁上部纵筋梁下部纵筋弯锚长度15d箍筋梁上部纵筋弯锚长度L a中间支座纵向钢筋构造(节点①~③)注:括号内数字用于非框架梁柱、墙或梁hcΔh50当Δh/(hc-50)≤1/6时,上部纵筋连续布置用于中间层,当支座为梁时也可用于屋面35015d 0.75ll50柱、墙或梁50当l <4hb 时,可不将钢筋在端部弯下可用于中间层或屋面115d5015d0.75ll50h b 伸至柱外侧纵筋内侧,且≥0.4lab当l <4h b 时,可不将钢筋在端部弯下至少2根角筋并不少于第一排纵筋的1/2,其余纵筋弯下第一排第二排柱或墙≥10d ≥10d≥12d纯悬挑梁XL柱、墙15dhc≥la 且≥0.5hc +5d≥0.4lab (≥0.4labE)ΔhΔh/(hc-50)>1/6仅用于中间层2图集号16G101-1-92伸至柱外侧纵筋内侧,且≥0.4L ab当L 小于4hb 时,可不将钢筋在端不弯下柱或墙柱,墙或梁当L 小于4hb 时,可不将钢筋在端不弯下柱或墙柱,墙或梁锚固长度15d锚固长度15d 梁下部纵筋悬挑梁上部纵筋锚固长度La 箍筋箍筋梁上部纵筋梁下部纵筋纯悬挑梁XL 及各类梁的悬挑端配筋构造框架梁锚固长度≥0.4L ab,(≥0.4L abE )弯折长度15d 15d支座边缘线纯悬挑梁纯悬挑梁图集号16G101-1-92弯锚长度15d 伸至柱对边纵筋内侧,且≥0.4L ab 柱,墙或梁梁下部纵筋梁上部纵筋柱,墙或梁梁上部纵筋箍筋梁下部纵筋梁下部纵筋箍筋纯悬挑梁XL 及各类梁的悬挑端配筋构造柱或墙箍筋锚固长度≥L a (≥L aE )≥L a (≥L aE )且伸至梁底锚固长度≥L a (≥L aE )柱,墙或梁≥L a (≥L aE )且伸至梁底锚固长度≥L a (≥L aE )锚固长度≥0.6L ab )柱、墙hcΔh/(hc-50)>1/6仅用于中间层15dΔh≥la 且≥0.5hc +5d伸至柱外侧纵筋内侧,且≥0.4lab 4柱、墙或梁hc当Δh/(hc-50)≤1/6时,上部纵筋连续布置用于中间层,当支座为梁时也可用于屋面5柱、墙或梁hcΔh ≤hb/3时,用于中间层,当支座为梁时也可用于屋面h bΔh≥la 且≥0.5hc +5d≥l a (≥l a E )且伸至梁底6柱、墙或梁hcΔh ≤hb/3时,用于中间层,当支座为梁时也可用于屋面Δh≥l a 且伸至梁底≥0.6lab≥la(≥laE)7悬挑梁端附加箍筋范围b b h150Sh 1(≥la E 且≥0.5hc +5d )图集号16G101-1-93框架扁梁中柱节点框架扁梁中柱节点核心区钢筋框架扁梁上部纵向受力钢筋框架扁梁下部纵向受力钢筋框架扁梁节点核心区附加纵筋框架宽扁梁KBL 框架宽扁梁KBL框架柱板框架边梁箍筋与拉筋图集号16G101-1-94框架扁梁边柱节点(一)框架扁梁中柱节点核心区钢筋框架扁梁上部纵向受力钢筋框架扁梁下部纵向受力钢筋框架扁梁节点核心区附加纵筋框架扁梁KBL 框架扁梁KBL框架柱板框架边梁箍筋与拉筋U形箍筋U形箍筋箍筋非加密区箍筋非加密区箍筋加密区箍筋加密区箍筋加密区箍筋加密区图集号16G101-1-94框架扁梁箍筋构造图集号16G101-1-95框架扁梁边柱节点(二)框架扁梁中柱节点核心区钢筋框架扁梁边柱节点核心区钢筋U 形箍筋U 形箍筋U 形箍筋U 形箍筋图集号16G101-1-96框支梁KZL框支梁KZL 、转换柱ZHZ 配筋构造框支梁KZL转换柱ZHZ转换柱ZHZ剪力墙梁板≥15d505050≥15d≥laE≥l a E (l a )≥l a E (l a )ln1/3ln1ln2ln/3ln/3≥0.4labE ≥0.4labE≥0.4labE ≥0.2ln1,≥1.5hb 箍筋加密区≥0.2ln1,≥1.5hb 箍筋加密区≥0.2ln2,≥1.5hb 箍筋加密区伸至梁上部纵筋弯钩段内侧,且伸至对边柱纵筋弯钩段内侧,且总锚固长度≥laE,直锚不足时可玩锚,伸至梁纵筋弯钩内侧,且水平段的长度≥0.4labE,弯折段长度≥15d图集号16G101-1-96框支梁KZL框支梁KZL 、转换柱ZHZ 配筋构造ln1/3ln/3ln/3≥15d505050≥15d≥laE≥l a E (l a )≥l a E (l a )ln1ln2≥0.4labE ≥0.4labE≥0.4labE ≥0.2ln1,≥1.5hb 箍筋加密区≥0.2ln1,≥1.5hb 箍筋加密区≥0.2ln2,≥1.5hb 箍筋加密区伸至梁上部纵筋弯钩段内侧,且伸至对边柱纵筋弯钩段内侧,且总锚固长度≥laE,直锚不足时可弯锚,伸至梁纵筋弯钩内侧,且水平段的长度≥0.4labE,弯折段长度≥15d1-1拉筋直径不宣小于箍筋两个规格,水平间距为非加密区箍筋间距的2倍,竖向沿梁高间距≤240,上下相邻两排拉筋错开设置墙体竖向钢筋锚固长度≥laE(la)边缘构件纵向钢筋错固长度≥1.2laE(1.2la)框支梁钢筋构造与框架梁钢筋构造类似不同之处在与框支梁主要承受剪力墙的线荷载框架梁的受力较为复杂。