气体汇流排技术要求
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Technical requirement/技术要求
1.Purpose/目的
Buy one set gas busbar to use on T-floor flaming equipment, the gas from different bottle comes together and reduce the pressure by valve, then supply to flaming equipment, it also requires to meet safety requirement /购买一件汇流排,用于T-board喷胶烤火,将瓶装气汇流减压后供送到烤火设备上,同时满足安全要求。
2.Current Conditions/当前状况
2.1Ambient temperature: -10 ºC~+50 ºC. /环境温度:-10 ºC~+50 ºC;
2.2LPG bottle pressure: 0.4~09Mpa. /丙烷气瓶出口压力0.4~0.9Mpa;
2.3The quantity of flow and pressure is 25m3/h and 0.05Map. /烤火设备要求的流量和压力
25m3/h,0.5bar;
2.4output end require 1.5’/输出端要求为1.5英寸;
3.Technical Requirements
3.1.During the design, manufacturing, installation and run equipment must be in accordance
with GB standard/设备的设计、制造、安装、运行,必须符合相关标准规定;
3.2.Manual change switch,4 bottle in using and 4 bottle for backup,the Max.pressure is
15Mpa,the outlet pressure range is 0.03-0.85Mpa,can be adjusted according to
requirement/双侧式手动切换,钢瓶4用4备,最高输入压力15MPa,输出压力0.03~0.85MPa可调;
3.3.equip at least:soft sus pipe with high pressure,connection to bottle,filter,reduction
valve,pressure gage,flashback arrestor for propane/ 配置至少包含:不锈钢高压软管、钢瓶接
头、过滤器、减压阀、压力表、丙烷专用回火防止器;
3.4. The Gas bus must have the quality certificate, certificate of pressure inspection, the
pressure gage must have the quality certificate, the manufacturer must have the qualified
certification for Gas busbar/ 汇流排必须有出厂合格证和压力测试合格报告,压力表具有合格证,生产厂家必须具有汇流排制造资质许可证;
3.5.Offer the spare part list for gas bus,such as soft pipe ,filter, reduction valve,flashback
arrestor for propane/提供汇流排上使用备件的备件清单列表和型号,如软管,过滤器型号,减压阀型
号,丙烷专用回火防止器型号;
3.6.The instruction for maintenance and repair维护保养说明书