三相电力调整器(调功器)使用说明书

合集下载

ST35P三相智能调功调压一体化功率调整器 说明书

ST35P三相智能调功调压一体化功率调整器 说明书

斯通电子ST35P三相调功调压一体化电力调整器操作手册首先感谢您使用本公司的产品!在您使用之前请仔细阅读本说明书,如有疑问敬请电话垂询。

操作手册目录1.概述------------------------------------------------------------------------- 2.主要技术指标及主要功能简介---------------------------------------3.安装及使用须知----------------------------------------------------------4.装箱清单-------------------------------------------------------------------5.选型表---------------------------------------------------------------------- 6.ST35P接线说明-----------------------------------------------------------6.1常用的五种接线方式-----------------------------------------------6.2几点注意说明--------------------------------------------------------6.3整机接线图-----------------------------------------------------------6.4线性化调节输出示意图及缓起动的意义--------------------7. 接假负载调试-------------------------------------------------------------8.接实际负载调试----------------------------------------------------------9.电流限制(选件)-------------------------------------------------------10.过流报警功能(选件)--------------------------------------------------11.恒流功能(选件)-------------------------------------------------------12.电流环光隔离远程状态接口DDR-R(选件)------------------------13.调功/调压一体化功能(选件)----------------------------------------14.常见故障及解决方法----------------------------------------------------15.ST35P控制板端子位置布置图及部分功能设置说明------------16.外型尺寸图----------------------------------------------------------------17.电源接线端子示意图-----------------------------------------------------18.外型尺寸对照表------------------------------------------------------------ 1 1 3 3 3 4 4 4 5 6 6 6 6 7 7 8 8 91011 13 13ST35P三相调功调压一体化电力调整器操作手册概述斯通ST35P电力调整器2008年进行了全新的设计,其中包括软件的升级、散热单元的优化、新外观的设计等近6项的升级或改进,大大提高了产品的性能和可靠性。

三相电力调整器使用说明

三相电力调整器使用说明

使用说明书磊强自动化Leiqiang Automatio三相功率控制器型号:LQ3000系列上海磊强实业有限公司目录使用注意项.................................11.产品特点.................................22.技术规格...............................2-33.装箱清单.................................44.产品选型及外形尺寸.......................45.订货说明.................................46.电路示意图及输出波形...................5-67.安装及使用须知...........................68.接假负载调试.............................69.接实际负载调试...........................710.控制板常见接线组合......................711.调试中的问题及故障排除................7-812.加热器特性..............................813.不同负载的控制策略......................914.LQ3000控制器的基本特性图示..............915.调功、调压一体化功能...................1016.安装尺寸............................10-111.使用注意事项1. 请不要用手触及电力调整器内部,以防触电。

2. 请不要堵塞散热器上方,不要让杂物进入散热器内部。

否则可能影响机器使用寿命。

3. 在切断电源后一段时间内。

电力调整器的散热器,铜排等有可能处于高温状态,故请不要触摸,以免烫伤。

系列智能型电力调整器LQ3000系列电力调整器是大功率晶闸管模块应用技术的新产品。

三相交流调压器说明书

三相交流调压器说明书

KTF40A380V 三相交流调压器使用说明书单位:西安协科电子有限责任公司地址:西安市雁塔区朱雀大街88号邮编:7100612011年5月1日目录装置说明1,本装置型号意义--------------------------------------------------------1 2,技术规范-----------------------------------------------------------------1 3,工作原理-----------------------------------------------------------------2 4,装置电路图-------------------------------------------------------------4 5,控制板接口图----------------------------------------------------------5 6,装置元件布局----------------------------------------------------------6 控制板说明书--------------------------------------------------------------7一、概述----------------------------------------------------------------------7二、触发电路组成------------------------------------------------------------8三、适用装置-----------------------------------------------------------------8四、正常使用条---------------------------------------------------------------8五、主要技术参数------------------------------------------------------------8六、控制板的接线端子与参数-----------------------------------------------8七、发光二极管工作状态---------------------------------------------------10八、电位器-------------------------------------------------------------------10九、 同步输入---------------------------------------------------------------11十、 调试须知---------------------------------------------------------------11十一、控制板应用举例------------------------------------------------------11 XK104B、C在三相桥式整流电路中的应用-------------------------12XK104D在三相桥式整流电路中的应用-----------------------------13XK104B、C在三相相控调压电路中的应用-------------------------14XK104D在三相相控调压电路中的应用-----------------------------15附录A:PCB板------------------------------------------------------------16附录B:控制板接线图--------------------------------------------------17附录C:原理图-----------------------------------------------------------18模块资料-------------------------------------------------------------------19 XKMTC70AT120/180----------------------------------------------------------191,本装置型号意义:K T F-40A/380V3PH50HZ可控硅变流装置3相50Hz调压额定整流电压(V)风冷额定整流电流(A)2 技术规范:2.1 主要技术参数:a.额定输出电流: 40Ab.额定输出电压: 380Vc.负载等级: Ⅱ级 100% Idn 连续, 150%Idn 1分钟;d.冷却方式: 风冷e.主柜外形尺寸: 350×240 (长×宽)2.2 正常使用条件:本装置除了应满足GB3895-83《半导体电力变流器》、ZBK46-006-88《电化学整流器标准》外, 还应满足本产品的技术要求:a.环境温度: 户内不低于-5℃,不高于+40℃,24小时内的平均温度不超过30℃b. 空气最大相对湿度不超过90%c. 运行地点无导电及爆炸性尘埃,无腐蚀金属和破坏绝缘的气体或蒸汽。

KS36P用户手册

KS36P用户手册
移相控制
调功控制
缓启动 缓关断 电压限制 电流限制(选件) 急停 手动控制 启动/停止(外部开 关) 调压/调功(外部开 关,选件) 报警输出 过流保护(选件)
SCR 过热保护
电源缺相报警 电流等级
输入指示 LED 电源相位指示 LED
380V AC ±10% 50HZ
380V AC ±10% 50HZ,要求与负载电源同相位
开箱时,请仔细确认铭牌上的型号是否与订货型号一致,是否有运输过程中对产品 的破坏现象,如发现问道请及时与我公司取得联系。
1.2 安全及注意事项
表示没有正确使用,可能导致设备严重损坏和人员伤亡!
安装:
表示没有正确使用,可能造成设备和人身某种程度上的伤害!
要求安装在金属等不可燃物体上,正方向垂直安装, 要求安装在通风良好的环境下,电气柜要求安装排风扇 不要将螺丝等金属物掉进控制器内部,可能会有引发爆炸和发生火灾的危险! 要求安装在无剧烈震动和冲击的地方,无导电尘土,潮湿的气体或蒸汽环境中 配线:
必须由具有专业资格的人员更换由我公司提供的原装部件!
z 使用前请认真阅读本说明书,严格按要求接线使用。 z 本功率调整器是壁挂式,垂直安装在通风良好,不受日光直射或热辐射,无腐蚀性无
可燃性的环境中。 z 装置过热保护后,如要再运行,需排除故障后,再送电运行。 z 负载应无短路、局部放电打火等现象,要求绝缘良好。 z 在使用过程中若发生过流现象,应首先检查负载有无短路等故障。 z 过流保护:一般地说,过流保护不能完全确保负载短路造成的设备损坏,不能代所选功率调整器的电流容量应大于负载的最大电流; ●硅碳棒负载: 当取消变压器时,硅碳棒应串联,硅碳棒在 600-800℃存在负阻区,所选 的电流容量应大于负载的 2 倍以上. ●电热管负载: 易受潮,局部短路等.所选的电流容量应大于负载电流的 2 倍以上. ●变压器负载: 应带有电流限制,过流报警功能,所选功率调整器的电流容量应大于负 载电流的 2 倍以上. 定货例:KS36P-Y-200-C-N-00 注:输入为 0-10VDC 的用户需订货特殊申明 说明: KS36P 三相功率调整器,(移相调压,自动判相,散热超温报警,电源却相报警,输入信 号:4-20mA DC 控制板电源为380VAC),星型中心不接地或三角型.电流容量200A (注:纯阻负 载最大电流 200A;硅碳棒负载电热管负载最大电流 100A,变压器负载最大电流 100A;),带电流 和过流报警选件功能.

三相电力调整器PA300B说明书

三相电力调整器PA300B说明书

★ 输出限制特性 100%
无缓起动
时间
额定
带缓起动
电流
缓起动带电流限制
应用案例
时间限制 0.2~120 sec.
通一个正弦波 断一个正弦波
通九个正弦波 断一个正弦波
★ 最大电流限制 电流限制可调整范围 20~100% 100%
电流
0%
100% 200% 300%
负载系数
★ 外接最大电压线性限幅(斜率调整)
感 性 负载( 变 压器一 次 侧)
输 出斜 率 设定:
输 出 范 围0 ~10 0 %
输 出截 据 设定:
输 出 范 围0 ~10 0 %
输 出手 动 设定:
输 出 范 围0 ~10 0 %
电 流限 制 设定:
限 制 最 大输出 电 流,外接10 KΩ电 位器,调节 范 围2 0 ~100%
过 流保 护 系统:
相位检测 及驱动输出
T
+ SSR -
CN 2
相位检测 及驱动输出
S
+ SSR -
CN 1
相位检测 及驱动输出
R
l 输入指示灯 绿色指示
P1 电位器 前置放大 量程调整
C1 C2
GND
IN
P2 电位器 过流设定
R1 R2
P3 电位器 缓起时间调整
R3
V0
CT
SW 1 工作方式开关
ON
123
RS
L1
FU SE L2
-25-
触发方式及输出波形
触发方式
干扰
移相调压型

1 0%输出
输出波形图 5 0%输出
FAS 富安时
9 0%输出

三相 180A~300A 可控硅功率调整器使用说明

三相 180A~300A 可控硅功率调整器使用说明

厦门伯特产品系列三相180A~300A 可控硅功率调整器使用说明(V5.0)BTK 智能可控硅功率器采用微处理器设计,宽脉冲触发方式稳定可靠,且接线简便。

适用于各类单、三相阻性或感性负载。

在电路结构上,由于采用板卡+模块化设计,功能组合、升级灵活方便。

高性能开关电源,可在极宽的电源波动范围内正常工作。

具有多种输入规格,控制输入与触发输出光电隔离。

既可以与各种自动化仪表配套使用,也可以单独手动操作控制,手操分辨率可达1/1000。

且手动/自动为无扰切换。

广泛应用于负载要求连续平滑调节、低电压大电流以及控制精度要求较高或不允许大电流冲击的单、三相控制系统,如交直流调压、充电,交、直流电机调速等,具有很高的性价比。

一 主要技术指标z 外控制输入规格: 0-5V 、1-5V ;0-10mA 、4-20mA 、0-20mA ; z 手动操作分辨率:1/1000 电流显示分辨率:1A z 软起动时间:0-300s 任意设定 z 软关断时间:0-300s 任意设定 z电源电压:85-264V AC DC二、选型规则系列号 类型 控制方式 负载类型 控制输入 辅助1辅助3额定电流(A) 说 明BTK悬挂式可控硅功率调整器A交流D 直流C移相 K过零 1 单相 2 两相3 三相Y 形不接零或△接法 4三相四线制1 0-10mA 24-20mA 3 0-20mA 40-5V 5 1-5V 60-10V N 无功能J1过流报警输出模块;常开+常闭,8A/220V N 无功能R RS232通信模块 SRS485通信模块xxx 每相允许的最大电流三、外形及尺寸规格图1 图2 图3 图4四、端子接线4.1 控制部分接线 4.2 主回路部分接线85-264V 4-20mA 与1-5V 位置相同; 精密电阻转换;0-10mA 与0-5V 位置相同; 精密电阻转换;三相进线注意事项:1.主回路应加装比产品标注的额定电流大20%的快速熔断器;2.如果负载是三相三线制Y 型接法,不能将中性点接零线。

PAC03I三相电力调整器操作手册

PAC03I三相电力调整器操作手册

450
H3450P 固态继电器,平均电流最大 220A
500
H3500P 固态继电器,平均电流最大 250A
N无
C 过流保护功能,适用于硅碳棒、变压器负载
N无
F 状态扩展功能,配希曼顿 XDR
U00
调功选件,具体见表
1 厂内安装
1 厂内调试
5
2. 产品系列
型号
PAC03I-B160PAC03I-B227PAC03I-B301PAC03I-B361PAC03I-B401PAC03I-CS600-
PAC03I 系列三相电力调整器(说明书中简称 PAC03I 整机)由 PAC03I 触发板、PAC03I 专用散热器、风机、外 壳等组成。核心部分使用 PAC03I 控制板;散热系统采用高效散热器、低噪音风机。整机电流容量从 40A 到 500A 有多个等级。
该电力调整器可与带0~5V、0~10V或4~20mA等的智能PID调节器或PLC配套使用,也可独立使用手动功能。PAC03I 电力调整器的负载类型可以是三相阻性负载、感性负载及变压器负载;负载方式可以是星形中心接地负载、星形 中心不接地负载、三角形负载。PAC03I可广泛应用于工业电炉的加热控制、冶金、化工、纺织机械等领域。
150
H3150PE 固态继电器,平均电流最大 60A
N无
C 过流保护功能,适用于硅碳棒、变压器负载
N无
F 状态扩展功能,配希曼顿 XDR
U00
调功选件,具体见表
1 厂内安装
1 厂内调试
3-1 散热器 3-2 模块
3-3 过流保护
3-4 状态扩展
B227
自然散热,每相最大散热电流为 100A, 具体尺寸见图 17-B

PAC03I 三相 SSR 电力调整器产品 说明书

PAC03I 三相 SSR 电力调整器产品 说明书

智能交流电力控制器是中日合作超大功率固态继电器应用技术的新概念产品。

它包括三相调压/调功一体化PAC03I、工业DCS周波过零控制器ZAC10及后续系列。

额定电流40~500A,带锁相环同步电路、自动判别相位、缺相保护、上电缓启动、缓关断、散热器超温、快熔检测、电流限制、电压反馈、过流保护、串行工作状态指示、串行遥控操作器、PAC03IA还能与上位机通信,实现系统集成。

智能交流电力控制器可广泛用于工业各领域的电压调节,恒压,恒流,恒功率调节,适用于电阻性负载、电感性负载、变压器和电机软起控制等。

一. PAC03I主要技术指标:4~20mA输入: 接收阻抗120Ω 调节输出分辨力:0.2°,三相触发不平衡度:不大于0.6°负载方式: PAC03I 50Hz 三相380VAC 三角形或星形中心不接地。

移相范围:0~150°50Hz 三相380VAC 星形中心接地(220V负载) 移相范围:0~175°50Hz 三相380VAC 半控整流桥。

移相范围:0~175°隔离驱动输出:8V峰值脉冲,8°~ 120°可变脉宽,每路可2串2并接4支同相SSR。

最大驱动电流:< 30 mA纯阻电流等级:60A、90A、120A、180A、250A、300A 散热单元:B160、B227、B301A、B361、B401配置见选型表五只LED灯状态显示:红绿黄LED三相电源指示和快熔断路指示;绿色INPUT输入信号线性指示灯。

三色状态灯: RUN绿色运行灯;ALM红色报警灯;STOP黄色闪烁的待机灯。

外部执行开关的缓起动,缓关断: 无电压接点输入 闭合(ON):缓关断,时间固定3秒;开路(OFF): 由内部电位器P3设定0.2~120秒缓起动时间 不接:直接运行运行过程中自动缓起动及急停: 运行过程中瞬间缺相急停,加电后自动缓起动(三缺一相方式时被取消)。

三相电力调整器使用说明

三相电力调整器使用说明

三相电力调整器使用说明
1.安装和连接
首先,将三相电力调整器安装在合适的位置,确保通风良好,并与电源和负载设备连接。

连接时,请注意正确接线,以避免电路故障和安全事故。

可以请专业人员进行安装和连接,以确保正确和安全的操作。

2.电源和负载检查
在启动三相电力调整器之前,需检查电源和负载设备的电压和电流参数。

确保输入电源符合三相电源的参数要求,并且负载设备的电压和电流在调整器的额定范围内。

如有问题,请及时解决或调整。

3.调整器参数设置
将三相电力调整器连接到控制系统或人机界面,通过设置控制参数来实现对三相电力的调整。

参数设置通常包括输出电压、电流和功率的目标值,响应速度和稳定性等。

根据具体需求,设置适当的控制策略和参数。

4.运行和监测
启动三相电力调整器,监测其输出电压、电流和功率的实际值,并与目标值进行比较。

保持监测和记录,以便随时调整和优化。

同时,注意监测调整器本身的工作状态,如温度、电流和故障等,确保设备正常运行。

5.故障排除和维护
6.安全使用
在使用三相电力调整器时,请严格遵守相关的操作规程和安全标准。

确保设备接地良好,并远离水源和易燃物。

避免设备过载运行和超过额定
参数,以免损坏设备或引发安全事故。

同时,定期对设备进行安全检查和测试。

CONCH奇胜-SCR三相电力调节器说明书

CONCH奇胜-SCR三相电力调节器说明书

CR SCR 系列電熱調整器()使用說明書琦勝企業有限公司CONCH ELECTRONIC CO.,LTD-3 A 2035P控制輸出 選購功能 電壓規格 電流規格 控制方式1:2:3223:33單相相線 單相線相線D:A:V:W:標準型電流偵測電壓偵測功率偵測2:220V 4:440V (380V)035:35A : :450:450AP:Z:C:3相位零位相半波(空白):單相自行設定220, 380, 440V 15% 50/60HZ±200240VAC 90~240V AC/DC()~(附掛風扇機種)。

無風扇機種35A,50A,75A,100A,125A,150A,225A,300A,450A 相位控制或零位控制單相機種可自行設定()0~5V,1~5V(20K)0~10V,1~10V(100K)0~20mA,4~20mA(250)阻抗阻抗阻抗歐姆類比控制:阻抗對應。

控制0~5V(20K)0.0~100.0%on/off :Hi=3.4V,Lo=2.2VRS-485ModBus RTU ASCII 介面,支援協定或格式。

0.1% / 1%依規格採自然冷卻或附掛風扇AC2000V/1分鐘電源端、訊號端及散熱片間)(2KV 5KHZ20M /500V Ω以上電源端、訊號端及散熱片間)(ABS (UL94V)主電源電壓控制電源額定電流控制方式控制信號VcmdE ADJ .控制訊號串列通訊解析度線性度/冷卻方式環境溫度溼度/耐壓強度耐雜訊絕緣阻抗外殼材質-10~+50C/under 90%RH°0.0~100.0%輸出控制範圍請確定控制訊號的輸入類別再依據下表調整,以免發生控制異常。

位於主控板上的開關DIP S W 1lCRx-xxxxP /相位零位控制設定注意變更控制模式必須重新開機:外觀圖示DOC No.T10-00024/ V2.013425異常顯示按住鍵清除([SET]+[UP])Vcut=”0V ”,HLtd=90%,LLtd=10%的控制效果STUP=10s (的輸出延遲效果5)開機或待機超過分鐘RESP=2s 的輸出延遲效果Vcut=”LLtd ”,HLtd=100%,LLtd=10%的控制效果● 最小/最大輸出量與的關係Vcmd(Ccmd)● 緩啟動時間反應時間與輸出的關係(STUP),(RESP)註:為通訊控制訊號請參考通訊控制Ccmd ,[]本控制器可以利通訊方式操控的輸出量,以取代的作用。

Eaton Power-Sure 700三相电压调节器说明说明书

Eaton Power-Sure 700三相电压调节器说明说明书

Eaton Power-Sure 700 (10–500 kVA,three-phase voltage regulator)The Eaton Power-Sure ™ 700 reduces equipment downtime through constant voltage regulation. It is the ideal solution for equipment orfacilities experiencing brownouts and voltage regulation problems. The unique design of the Power-Sure 700 offers a high in-rush current, rapid response and operating advantages over other manufacturers.OverviewThe appropriate transformer tap is automatically activated through a silicon-controlled rectifier (SCR), maintaining a tightly regulated output voltage. Tap changes are initiated within one electrical cycle—switching at zero current crossing to ensure a minimum amount of noise during tap transitions. Seven taps per phase are used for optimal voltage regulation. Also, the Power-Sure 700 is a low output impedance, shielded isolation transformer. As a result of the lowimpedance, load changes do not affect other equipment connecting the system.The Power-Sure 700’s unique design ensures high efficiency at 97% and 1000% in-rush capability. It is equipped with a thermal-magnetic breaker that allows for proper system coordination to prevent nuisance trips.The Power-Sure 700 provides the triple function of isolation, noise attenuation and voltage regulation. The power transformer supplies the first two functions. The third function, voltage regulation, is supplied by the SCRs connected to taps on the power transformer. This sequential tap-changing design eliminates voltage “overshoot” from typical electronic voltage regulators, providing a seamless transition between the required power transformer taps.Power-Sure 700 features•±3% voltage output for a +10/–23% voltage input •Power factor—the Power-Sure 700 is notaffected by load power factor •Total harmonic distortion (THD)—the Power-Sure 700 adds less than 1% added to the output waveform under any dynamic linear loading conditions presented to the line regulator • High efficiency—97%•Wide input frequency range—the Power-Sure 700 operates within a broad input frequency range of 57–63 Hz•Integral manual rotarymaintenance bypass switch standard on 50–500 kVA units and optional on smaller units •Seven taps per phase used to provide optimal voltage regulation•Fail-safe bypass circuit, triple- shielded isolation transformer and overtemperature protection•One-year parts warranty with no startup required •Front-only access required (50–150 kVA units only) allows unit to be installed in tight spacesEaton is a registered trademark.All other trademarks are property of their respective owners.Eaton1000 Eaton Boulevard Cleveland, OH 44122United States © 2021 EatonAll Rights Reserved Printed in USAPublication No. PA158001EN / Z25666November 2021Power-Sure 700 ordering guidelinesA Units with no surge protection option, bypass option or metering option will have blanks in the last three spaces in the catalog number.B Bypass is standard on 50 kVA and larger units and an option on 45 kVA and smaller units.otes: NListings—UL ® Listed, CSA ® Certified, except for 600 V;no UL, CSA on 600 V units. For output distribution, call factory. K factor–rated units available on request.For product support, please contact Eaton’s Technical ResourceCenter (TRC) power quality application engineers at 1-800-809-2772, choose option 5 and then option 2, or *************.For more information, visit /pc .Follow us on social media to get the latest product and support information.。

三相电力调整器(调功器)使用说明书

三相电力调整器(调功器)使用说明书

目录安全及注意事项 (I)第一章H系列三相功率控制器的作用及特点 (1)1.1 作用 (1)1.2 特点 (1)第二章产品信息 (3)2.1 型号定义 (3)2.2 铭牌 (3)2.3 产品规格 (4)2.4 技术参数 (4)2.5 缩略语 (5)第三章安装及配线 (6)3.1 开箱检查 (6)3.2 使用条件 (6)3.3 安装 (7)3.4 电气配线 (7)3.5 基本接线原理图 (8)3.6 端子说明 (9)第四章显示及操作说明 (10)4.1 监控界面显示信息说明 (11)4.2 按键功能说明 (11)4.3 操作举例说明 (12)4.4 菜单 (12)4.5 控制参数A (13)4.6 显示参数B (13)4.7 保护参数C (13)4.7 保护参数C (14)4.8 高级参数D (14)第五章功率控制器功能介绍 (15)5.1 功能介绍 (15)5.2 功能参数表 (22)5.3 参数说明 (23)5.4 举例说明 (32)第六章故障处理及保养维护 (35)6.1 故障处理 (35)6.2 保养维护 (35)第七章通信说明 (37)7.1 通讯数据读写 (37)7.2 协议内容 (37)7.3 总线结构 (37)7.4 通讯帧结构 (38)7.5 MODBUS通讯协议 (38)第八章售后服务 (40)附表一 (41)I安全及注意事项危险:由于没有按要求操作,可能造成设备严重损坏或人员伤亡的场合。

注意:由于没有按要求操作可能造成中等程度伤害或轻伤,或造成物质损失的场合。

本指示对于正在工作的功率控制器非常重要,忽略这些指示可能对您造成身体损害甚至导致死亡。

○1安装控制器应安装在金属等不可燃物上,否则有发生火灾的危险。

不要安装在含有爆炸性气体的环境里,否则有引发火灾的危险。

不要把易燃、易爆物品放在控制器附近,否则有引发爆炸的危险。

不要将螺钉、垫片等金属物掉进控制器内部,否则有引发爆炸和发生火灾的危险。

SCR-LA三相电力调整器说明书

SCR-LA三相电力调整器说明书

SCR-LA 三相电力调整器-3-三、产品外形、安装尺寸及接线方式注:(单位mm )90%。

温度下限为-30℃,温度上限为+40℃。

七、开箱及检查八、订货须知品合格证 用户在订货时,请注明产品的型号、规格。

如有特殊要求,请与制造商协商。

打开外包装纸盒,检查包装盒内应有使用说明书,产。

5.3 故障排除:原因;检查线路无误后按安装,使用操作说明操作;确属产品本身质量问题的产品,请与当地经销公司或我公司联系。

当产品出现故障后,首先断开电源,然后查找故障六、运输与贮存产品贮存和运输过程中不受到雨雪的侵袭,及挤压,贮存时应放置在空气流通,相对湿度(25℃±5℃)不超过九、公司承诺自产品生产日期起二十四个月内,在客户正常的储运、保养、使用条件下,因产品的制造质量问题而不能正常使用时,提供“三包”服务。

浙江省乐清市柳市镇电器城3单元电话:(86-577)6711 8888 邮编:325604客服热线:400-826-8008传真:(86-577)6711 8000本使用说明书自2013年09月第一版163mm113mmRSTUVW165mm95mm100mmRSTUVWRSTN禁止接零线R S TU V WRST星型接法三角接法控制回路接线说明M最小输出调整BIASMAX最大输出调整内 部 电 源5VDC外部信号输入4mA ~20mA 0V ~10VDC 0V ~5VDC 控制回路接线说明MBIASMAX2K ~10K ΩΩ4mA ~20mA0V ~5VDC0V ~10VDC0V ~5VDC自动控制手动控制指示灯功能说明随着输出电压的增大逐渐变亮随着控制信号的增大逐渐变亮负载端电源接通时亮快速熔断器熔断时亮四、安装、使用操作说明-4-4.1要求(注意三相电接入方向,不能接反)U 、V 、W 接负载,三相负载要平衡,负载可以星型接法和三角接法。

星型接法时,中点禁止接零线。

4.2、控制端分为自动控制和手动控制。

TR-CTH三相调整控制器使用说明

TR-CTH三相调整控制器使用说明

一、产品简介1、面板多只LED指示灯,显示SCR电力调整器的工作状态及故障原因,方便有故障时及时进行维修。

2、PC板采用SMD贴片原件,抗干扰性佳,故障率低,绝无任何干扰现象。

3、内含缓启动功能,急速变化时更平稳使原件更耐用。

4、比例式线性输出,控温精确,精度0.3%符合各种负载要求。

5、整机采用铝合金,体积小散热效果佳,100%的引导风扇气流散热。

6、输入方式:4-20mA DC1-5V DC2-10V三种方式由P1 JUMP自由切换选择不需更换主机。

7、全系列加装高速保险丝及过热停止输出保护开关,保护电力调整器。

8、使用环境温度-10℃~45℃,湿度90%以下不结露。

9、PC板AC1 AC2端子输入电源电压AC200~240V。

10、主电源与PC板工作电压无相序先后关系,使用方便(50HZ~60HZ自动辨识)。

11、安装于密闭式控制箱内须有空气对流孔及冷却排风扇,如散热不良请低于70%功率使用,否则会造成电力控制器过热保护功能启动而停止输出。

12、工作中请不定时检查风扇的工作状态是否正常,如果不正常需排除风扇故障后再投入正常使用。

二、调整器使用说明输入信号INPUT:功能调整:使用万用表测量+ -端子电阻BIAS ( VR4) 最小输出量4~20mA 输入阻抗250ΩMAX (VR5) 最大输出量DC1~5V 输入阻抗30KΩVR1 VR2 VR3均不需做调整DC2~10V 输入阻抗12KΩ(图一接点信号控制)(图二电压、电流信号控制)图三电压、电流、输出由VR调整控制)指示灯功能PWL PC板工作电源指示(主电源通电时亮)IN 温控表输入信号(随温控表输出信号大小变化)OUT SCR输出指示(随SCR输出量大小变化)(零位闪烁)ERR 故障指示(SCR超温)(SCR超温时亮,改善通风效果)FB 故障指示(主电源异常)RUSV(图四CTH系列产品面板示意及指示灯功能说明)注意事项:●建议使用前先用3只电灯泡(功率≥100W )星形接法(共点不接零)做负载调试正常再投入使用。

三相电力调整器使用说明

三相电力调整器使用说明

使用说明书磊强自动化Leiqiang Automatio三相功率控制器型号:LQ3000系列上海磊强实业有限公司目录使用注意项.................................11.产品特点.................................22.技术规格...............................2-33.装箱清单.................................44.产品选型及外形尺寸.......................45.订货说明.................................46.电路示意图及输出波形...................5-67.安装及使用须知...........................68.接假负载调试.............................69.接实际负载调试...........................710.控制板常见接线组合......................711.调试中的问题及故障排除................7-812.加热器特性..............................813.不同负载的控制策略......................914.LQ3000控制器的基本特性图示..............915.调功、调压一体化功能...................1016.安装尺寸............................10-111.使用注意事项1. 请不要用手触及电力调整器内部,以防触电。

2. 请不要堵塞散热器上方,不要让杂物进入散热器内部。

否则可能影响机器使用寿命。

3. 在切断电源后一段时间内。

电力调整器的散热器,铜排等有可能处于高温状态,故请不要触摸,以免烫伤。

系列智能型电力调整器LQ3000系列电力调整器是大功率晶闸管模块应用技术的新产品。

欧式风格三相电力调整器PAC30A操作指南说明书

欧式风格三相电力调整器PAC30A操作指南说明书

欧式风格三相电压调整器Continental style three-phasevoltage regulatorPAC30A 使用说明书OPERATINGINSTRUCTIONS希曼顿电子科技有限公司X imandun Electronic Technology Co., LtdXIMANDUN简介希曼顿电子科技有限公司,创立于1985年,是以设计开发、生产、销售全系列工业级交流固态继电器(SSR)、一体化电力调整器为主的高新技术企业,并荣获超大功率SSR、全数字化SSR控制器和柔性导热垫片等多项国家专利。

PAC30A产品概述全新PAC30A智能三相调压器以令人惊叹的完美设计开创数字式调压器的新纪元。

它操作和维护简单,独立的三只电力模块,易于散热和维护,并避免了危险集中。

欧式风格的安全防尘结构,美观大方。

红绿蓝色LED灯,工作状态一目了然。

CS插片式散热器比普通散热器的散热效率高30%~100%。

其它功能还包括:手动/自动,最大电压限制,自动判相,缺相保护,上电缓启动、缓关断、散热器超温,CS的霍尔转速检测接口,可广泛用于工业各领域中的阻性或感性负载。

订货说明1.电力调整器电流容量选择参考● 一般纯阻负载:电力调整器电流容量应大于负载最大电流。

● 硅碳棒负载:当取消变压器时,硅碳棒应串联,使之能够承受电源电压的70%~80%以上。

硅碳棒在700~800℃存在负阻区,电力调整器电流容量应大于负载最大电流的1.7倍。

● 电热管负载:电热管易受潮、局部短路和放电打火等,电力调整器电流容量应大于负载最大电流的1.7倍。

● 变压器负载:应带电流限制功能,电流容量应大于负载最大电流的2~2.5倍。

● 特殊负载应加大电流容量,订货时声明。

2.定货例:PAC30A-YT-150含义如下欧式风格三相电力调整器,负载接线方式为外三角形或中心不接地,纯组负载电流最大值为150A目录一.型号定义 (4)二.产品系列 (4)三.主要技术指标 (4)四.LED灯状态显示 (5)五.接线及应用 (5)六.初始调试 (6)七.常见故障及处理与保养维护 (7)八.尺寸图 (8)一.型号定义图1-1:负载电流150安培以下型号定义图1-2:电流150~600A 带霍尔风机型号定义注:PAC30A--40一般为自然冷却如需风冷,请订货时说明,尺寸与PAC30A--60相同四.LED灯状态显示五.接线及应用图1-3:全部功能实现接线及原理图图1-4:三相四线YN接线图各种功能接线实现组合六.初始调试为调试可靠、顺利进行,一般先接假负载(如:100~200W灯泡、电炉等)。

KTS3(Z3)三相功率控制器使用说明书

KTS3(Z3)三相功率控制器使用说明书
配 置 , 规 格 大 小 按 负 载 实 际 最 大 电 流 的1 . 3 - 1 . 5倍 配 置
第 5 页
四、参数设置
4 . 1 面 板 及 按 键 说 明
备注:面板显示器为选件,如果需要显示面板功能,订货时请申明!
7 5

SET




名称
1 设置键 SET 2 左移键 3 增加键 4 减小键 5 数码显示 6 ALM 7 RUN
显 示C相 电 流
SET 0-5
负 载 电 压 按住 S E T 3秒以上
显示负载电压
SET
注: 在0-1窗 口 当微机给定信号允许时 ( i )变 成 ( E )
表示输入信号由端子上的信号提供
表示输入信号由通讯提供
第 6 页
0-1 密码
1111
SET 1-1
斜率调整
SET 1-3
◆ 智 能 数 码 显 示 , 包 括 负 载 电 流 、 负 载 电 压 、 输 入 信 号 等 参 数
◆ 数 字 恒 流 , 恒 压 设 计
◆ 微 处 理 器 智 能 化 控 制 设 计
◆ 先 进 的 M O D B U S 现 场 总 线 通 讯 功 能 , 一 台 计 算 机 可 同 时 监 控 3 2 台 调 压/调 功 器 , 增 加 中 继 最 多 可 控 制2 4 7台 调 压/调 功 器 , 实 现 D C S 控 制 ◆ 数 字 锁 相 环 同 步 伺 服 电 路 。
KTS/Z3- □ □ □ □ □ 例如: KTZ3-62KVA/3*380 表示K T Z 3系列三相可控硅调压器/调功器,输入信号为 4-20mA,负 载接线方式为三角形或星形不接零线,额定功率为 6 2 K V A ,负载电压为三相380V,不带通讯。

TAC60I说明书 (1)

TAC60I说明书 (1)

150- 150A AC
360 长×230 宽×220 厚
电流容量
200- 200A AC
360 长×230 宽×220 厚
(一般纯阻负载,阻值恒定)
260- 260A AC
350 长×255 宽×236 厚
外形尺寸 mm
300- 300A AC
425 长×254 宽×250 厚
400- 400A AC
475 长×325 宽×260 厚
500- 500A AC
475 长×325 宽×260 厚
600- 600A AC
475 长×485 宽×260 厚
800- 800A AC
458 长×500 宽×324 厚
1500- 1500A AC
540 长×584 宽×339 厚
过流报警
C 过流报警和限0% 50HZ
3 电流容量
20,50,80,100,150,200,260,300,400,500,600,800,1500A AC
控 制板电 源与 功 电源:380V AC ±10% 50HZ, 要求与负载电源同相位
4 耗
功耗:5W 最大
风扇电源
5
电压:220V AC 电流:0.5 A 以下
加电后,逐步增加控制输入信号或调整手动电位器,使负载电压从小到大逐步增加。若 发现异常,需停机检查。
三相负载连接形式
Y0- Y0:星型中心点接零 TR- Δ:三角型;或 Y:星型中心点不接零
20-
20A AC
203 长×143 宽×113 厚
50-
50A AC
227 长×158 宽×185 厚
80-
80A AC
227 长×158 宽×185 厚

RK33P三相电力调整器-V3

RK33P三相电力调整器-V3
N- 无 F- 远程状态接口(含 DDR 远程状态接收器)
8.调功(选件)
00 无
01 阻性调功
04 感性调功
5.1.订货说明:
5.1.1. 电力调整器电流容量选择参考
一般纯阻负载:被选的调功器电流容量应大于负载最大电流。
硅碳棒负载:在不使用变压器时,硅碳棒应串联提高阻抗,使负载的最大电压达到电源电压的 70%以上。硅
0~5V DC 输入, 输入电阻 > 450KΩ
0~10V DC 输入, 输入电阻 > 450KΩ 2.3.控制方式
调压控制:连续调压
调功控制:阻性过零调功,感性特殊调功
2.4.调节输出分辨率(采用十位 A/D 转换):调相 0.2°,调功 20ms
2.5.起控点
输入起控点:4.6±0.1mA
调压时输出电压起控点: 8V(中心接地);15V(中心不接地)
4. 整机装箱清单表 RK33P 整机一台, 10K 2W 电位器(含刻度盘)两套, 说明书 1 份。 若需要恒流、过流保护、电流限制、状态发送,还需选择配件。
5. 整机选型表
代码功能 型号代码
代码含义
1.系列 RK33P-
基本功能:移相调压, 锁相环同步,宽脉冲触发
调节分辨率:0.2°(调压), 20ms(调功) 缓起动、关断时间:0.2~120 秒可调 报警输出:常开 1A 250V AC 基本报警:散热器超温,电源缺相
红色闪烁
运行时缺相
指示
状态 4
红绿交替闪烁
散热器超温
状态 5
黄绿交替闪烁
仅上电时三相电源缺相
状态 6
黄色闪烁
待机或者首次启动
IN
绿色输入 状态 1
绿色亮
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

目录安全及注意事项 (I)第一章H系列三相功率控制器的作用及特点 (1)1.1 作用 (1)1.2 特点 (1)第二章产品信息 (3)2.1 型号定义 (3)2.2 铭牌 (3)2.3 产品规格 (4)2.4 技术参数 (4)2.5 缩略语 (5)第三章安装及配线 (6)3.1 开箱检查 (6)3.2 使用条件 (6)3.3 安装 (7)3.4 电气配线 (7)3.5 基本接线原理图 (8)3.6 端子说明 (9)第四章显示及操作说明 (10)4.1 监控界面显示信息说明 (11)4.2 按键功能说明 (11)4.3 操作举例说明 (12)4.4 菜单 (12)4.5 控制参数A (13)4.6 显示参数B (13)4.7 保护参数C (13)4.7 保护参数C (14)4.8 高级参数D (14)第五章功率控制器功能介绍 (15)5.1 功能介绍 (15)5.2 功能参数表 (22)5.3 参数说明 (23)5.4 举例说明 (32)第六章故障处理及保养维护 (35)6.1 故障处理 (35)6.2 保养维护 (35)第七章通信说明 (37)7.1 通讯数据读写 (37)7.2 协议内容 (37)7.3 总线结构 (37)7.4 通讯帧结构 (38)7.5 MODBUS通讯协议 (38)第八章售后服务 (40)附表一 (41)I安全及注意事项危险:由于没有按要求操作,可能造成设备严重损坏或人员伤亡的场合。

注意:由于没有按要求操作可能造成中等程度伤害或轻伤,或造成物质损失的场合。

本指示对于正在工作的功率控制器非常重要,忽略这些指示可能对您造成身体损害甚至导致死亡。

○1安装控制器应安装在金属等不可燃物上,否则有发生火灾的危险。

不要安装在含有爆炸性气体的环境里,否则有引发火灾的危险。

不要把易燃、易爆物品放在控制器附近,否则有引发爆炸的危险。

不要将螺钉、垫片等金属物掉进控制器内部,否则有引发爆炸和发生火灾的危险。

控制器应安装在无导电尘埃、无破坏绝缘性能的气体或蒸汽的环境里。

安装在无剧烈震动和冲击的地方。

竖直安放,以利通风。

控制器有损坏或接线脱落时,请不要安装运行,否则有发生火灾、受伤的危险。

○2 配线必须由具有专业资格的人员进行配线作业,否则有触电的危险。

确认输入电源处于完全断开的情况下,才能进行配线作业,否则有触电的危险。

必须将控制器的保护接地端子可靠接地,否则有触电的危险。

不要将螺钉、垫片及金属物掉进控制器内部,否则有引发爆炸和发生火灾的危险。

控制器主回路端子与导线端子必须牢固连接,否则有损坏财物的危险。

严禁将交流电源接入控制板的输入控制端子,否则会损坏控制器。

接线电缆端子的裸露部分,一定要用绝缘胶带包扎好,否则有发生火灾、损坏财物的危险。

○3 维护必须由具有专业资格的人员才能更换零件,严禁将线头或金属物遗留在控制器内,否则有引发和发生火灾的危险。

运行前必须进行相关参数和线缆连接的确认,否则有损坏财物的危险。

前言感谢您使用西安西驰电气股份有限公司生产的H系列三相功率控制器。

为了充分发挥功率控制器的功能,确保操作者的安全,在使用前请详细阅读本说明书。

当您在使用过程中发现疑难问题而本说明书无法提供解答时,请与西安西驰电气股份有限公司或各地代理、经销商联系,我们将竭诚为您服务。

II第一章H系列三相功率控制器的作用及特点 H系列三相功率控制器是采用电力电子技术、微处理器技术及现代控制理论技术设计的具有当今国际先进水平的新型调节器设备,具有电压、电流、输出功率、频率、散热器温度等实时显示功能,欠压、过流等保护功能,内部全数字化隔离技术,风机自控,通讯等功能;集成开环控制、恒流(I、I2反馈)、恒压(U、U2反馈)、恒功率(P反馈)、定周期周波控制、变周期周波控制、恒压+周波模式、恒流+周波模式以及恒功+周波模式等多种控制方式于一体,使用灵活。

广泛应用于加热、灯光调节等场合。

1.1作用通过对电压、电流和功率的精确控制,从而实现对负载的精密调节作用。

并且凭借其先进的数字控制算法,优化了电能使用效率,对节约电能起了重要作用。

完善可靠的保护功能,更有效地保护负载及相关设备的安全。

1.2特点◆先进的微处理器技术采用高性能的ARM® Cortex™-M3 32位内核,内置高速存储器,工作于-40°C至+105°C 的温度范围,功耗低,抗干扰能力强。

◆友好的人机界面H系列三相功率控制器采用OLED液晶屏显示,使参数设定、读取更加便捷,故障及实时监控更加直观。

OLED的优点:○1不需背光板、主动发光,可视角度范围大、达170度左右,不受强光等限制、画质均匀;○2响应速度快,图像稳定;○3亮度高、色彩丰富、分辨率高;○4驱动电压低、能耗低,可与太阳能电池、集成电路等相匹配,同时具有抗震荡、耐低温(-40℃)等特性。

◆三种启停方式内置端子、通讯、以及开机自启三种启停方式,操作简单便捷。

1◆先进的通讯功能配有RS485通讯接口,方便用户网络连接控制,提高系统的自动化水平及可靠性。

内嵌Modbus标准协议,方便组态连接。

◆模拟信号控制用户可输入4~20mA(1~5V)或0~20mA(0~5V)标准信号(需要拨码开关配合),并具有正逻辑与负逻辑之分。

同时具有4~20mA或0~20mA标准模拟信号输出功能。

◆多种控制方式集开环控制、恒压模式(U反馈、U2反馈)、恒流模式(I反馈、I2反馈)、恒功模式(P 反馈)、定周期周波模式、变周期周波模式和相控+周波控制模式于一体。

◆强大的抗干扰性所有外部控制信号均采用隔离技术,适合在特殊的工业环境中使用。

◆电源频率自适应电源频率42~68Hz自适应功能,方便用户使用,提高了调节精度。

◆完善的保护功能全程检测电流及负载参数,具有电源欠压、电源过压、电源保护延时、过流保护、过流保护延时、晶闸管过热保护、频率保护等保护功能。

◆高精度测量采用24位专用ADC,确保了采样精度;电压、电流检测均为真有效值,保证了对非正弦波信号的精准测量;可对累计电量进行显示。

◆多种负载接线方式负载可接成星型中点接零、星型中点不接零、三角型接法,可通过参数轻松设定。

◆特有AAM 功能在多机工作于周波模式时,以总电流为控制依据,优化每台机器的导通区域,最大程度的避免了电流的叠加,从而实现减小电网冲的目的。

23第二章 产品信息2.1 型号定义2.2 铭牌在功率控制器的外壳上,贴有标识其型号及规格的铭牌,铭牌内容如图2.2所示。

图2.1 型号定义CPC产品代码系列代码:H、多功能型 S、标准型 M、迷你型额定电流电压等级:0.2、220V 0.4、380V 企业代码电源相数:1、单相 3、三相附加信息图2.2 铭牌42.3 产品规格结构尺寸 (mm)型号 电流等级 ABCDE重量 (Kg )CPC3H —025/0.4 25A CPC3H —040/0.4 40A CPC3H —075/0.4 75A CPC3H —100/0.4 100A CPC3H —150/0.4 150A 348205311.517022210CPC3H —200/0.4 200A CPC3H —250/0.4 250A CPC3H —300/0.4 300A CPC3H —350/0.4 350A 473265430.421027523CPC3H —500/0.4 500A CPC3H —700/0.4700A625475532300305492.4 技术参数主回路电压等级 AC380V±20% 42~68Hz 控制电压等级 100~240AC 50/60Hz 额定电流 0~700A 工作频率 42~68Hz4~20mA (1~5V )正逻辑、4~20mA (1~5V)负逻辑模拟输入0~20mA (0~5V )正逻辑、0~20mA (0~5V )负逻辑 模拟输出 0~20mA 、4~20mA 斜坡上升 0~120S 斜坡下降 0~120S控制给定源选择模拟量给定0、端子1 1、端子225~350A 结构外形500~700A 结构外形52、端子1 ADD 端子23、端子1 IADD 端子24、端子1 PRO 端子25、端子1 IPRO 端子2数字量给定6、通讯控制方式0、开环控制1、恒压模式 (U 反馈)2、恒压模式 (U 2反馈)3、恒流模式(I 反馈)4、恒流模式(I 2反馈)5、恒功模式(P 反馈)6、定周期周波模式7、变周期周波模式8、恒压+周波模式9、恒流+周波模式 10、恒功+周波模式 11、功率自动分配保护类别 参数范围备注过流保护100%-150%Ie (默认为120%)100%关闭此功能晶闸管过热保护0、禁止 1、允许(默认为允许) 晶闸管温度≥75℃ 频率保护 0、禁止 1、允许(默认为允许) 小于42Hz 或大于68Hz保护 其他保护电源欠压、电源过压等负载类型阻性/感性 负载接线方式(只针对三相)0、星型中点不接地 1、星型中点接地 2、三角型接法继电器输出常开(250V/5A ) 人机界面OLED 液晶显示 通讯 RS485通讯接口,Modbus RTU 通讯协议 环境 室内安装、洁净环境环境温度 - 10o C ~+ 40o C湿度 最大95%RH (无凝露) 海拨高度1000m 以下 冷却模式 自然冷却/强迫风冷 防护等级IP212.5 缩略语SCR 晶闸管 RS485 通讯接口 MODBUS 通讯协议RTU MODBUS 的一种通讯模式 RH 温度单位OLED 有机发光二级管(Organic Light Emitting Diode ) IP00、IP21 环境防护等级 TRMS 真有效值6第三章 安装及配线3.1 开箱检查1) 检查产品在运输中是否有损伤,如:外壳凹陷、变形,内部连线、连接件松动等。

2) 检查是否随机配备产品合格证、保修卡、装箱单、说明书等。

3) 产品出厂后依据保修卡对产品实行保修。

请您在收到货物后,认真填写保修卡并将保修卡寄回西安西驰电气股份有限公司或供货单位。

3.2 使用条件(1) 避免安装于多尘埃、金属粉末、腐蚀性、爆炸性气体等场合; (2) 环境湿度:90%RH 以下(不结露);(3) 环境温度:10~45ooC C 。

环境温度与功率控制器额定电流关系如图3.1所示:(4) 海拔高度:在海拔高度超过1000米的地区,由于空气稀薄造成功率控制器散热效果变差,按GB/T3859.2-93标准要求有必要降额使用,额定电流与海拔高度的关系如图3.2所示。

图3.1 环境温度与功率控制器额定电30 35 40 45 50 55 60℃1000 2000 3000 4000 500050%Ie60%Ie 70%Ie 80%Ie 90%Ie图3.2 额定输出电流与海拔高度关3.3 安装(1) 请勿安装在高温环境和通风不良的场合,否则请低于额定容量的70%使用;(2) 控制器须有空气对流通风孔,依照热气由下往上的原理安装通风孔或加装抽气对流风扇;(3) 不要安装在多导电尘埃、金属粉末、腐蚀性、爆炸性气体的场所;(4) 功率控制器使用时,内部会产生热量,安装时请垂直安装且两旁需预留空隙,避免造成散热不良引起的模块的快速老化和损坏。

相关文档