新版MDCS-I使用说明书
imatic电动执行器操作手册V1_17版
5
LEARN 模式......................................................................................................... 18
5.1 最重要的设定..................................................................................................................... 5.2 调整对比度........................................................................................................................ 5.3 如何设定语言..................................................................................................................... 5.4 LEARN 过程...................................................................................................................... 5.5 LEARN 菜单..................................................................................................................... 5.6 LEARN 过程最重要参数.................................................................................................... 5.7 LEARN 模式菜单结构和参数.............................................................................................
MWS-X1型称重转换仪使用手册
第一章概述MWS-X1型称重转换仪是由北京五岳信达科技有限公司设计开发的集动、静态称重为一体的单、双台面电子轨道衡称重仪表。
本系统大多器件选用进口名牌厂家芯片,并经过严格老化筛选制造而成。
它性能稳定可靠,精度高,长期稳定性好。
可广泛应用于以电阻应变式传感器做一次转换元件的整车计量式双台面电子轨道衡及其它符合特定软件判别逻辑的电子衡器领域中。
一、功能特点1、适合于所有以电阻应变式传感器作为一次转换元件双台面整车计量式动、静态电子轨道衡器场合。
2、该系统采用16位逐次逼近型A/D转换元件,采样速率为400次/秒。
3、系统有8路模拟量放大通道,可实现传感器的单只独立输入。
4、系统有传感器故障自动报警功能。
5、全部键盘数字调校及工作参数设置。
6、管理员可修改式密码的设置增强了系统称重数据的可信度。
7、并行打印机接口,可连接内部有汉字字库的打印机,(如EpsonLQ-1600K,LQ-300K等),实现汉字的打印报表。
8、具有CAN控制器局域网络接口可实现控制器的远距离组网。
9、具有两路完全隔离的RS─232C标准异步通讯接口,可联接车号自动识别系统装置,或大屏幕显示器。
10、具有一路完全隔离的RS─485标准通讯接口,可连接上位机。
11、12字×4行液晶显示模块可滚动显示列车的称重结果和仪表工作的各种提示信息。
12、具有精确的日历、时钟,自动闰年、闰月,不受断电影响。
13、具有自动零跟踪功能。
14、4路带隔离的数字信号输入和两路继电器触点信号输出功能。
二、前面板说明1、显示器:12字×4行液晶显示模块用于滚动显示称重结果数据,累计结果及仪表的所有提示信息。
2、键盘部分:16个轻触按键键盘,6个独立的功能键,10个和功能键合用的数字键。
当仪表工作在静态方式时,显示的数值不为零,且数值状态指示显示稳定时,按此键可使显示清零(在清零范围之内时)。
该键也是数字键的‘0’。
数字键的‘1’。
液晶显示器的下翻屏键。
ABB定位器新版操作说明
TZID-C 智能定位器简明安装及操作说明书(V3.1)ABB (中国)自动化有限公司 仪器仪表总部Tel: 021 5048 0101 F ax: 021 6105 6992HOT LINE: 8008190190 4006209919气路连接•使用与定位器气源端口处标识的标准接口连接气源气源的要求:仪表气体(无油、无尘、无水,符合DIN / ISO8573-1污染及含油三级标准,最大颗粒直径< 5um,且含量<5mg/m3,油滴<1mg/m3。
露点温度低于工作温度10k。
•连接定位器的输出与气动执行器的气缸电气连接根据下列接线端子图以及设计要求进行相应的配线(一般只需+11,-12,+31,-32)+11 -12 控制信号输入端子(DC4---20mA,负载电阻Max.410欧姆)+31 -32 位置返馈输出端子(DC4---20Ma,DCS+24V供电)+41 -42 全关信号输出端子(光电耦合器输出)+51 -52 全开信号输出端子(光电耦合器输出)+81 -82 开关信号输入端子(光电耦合器输入)+83 -84 报警信号输出端子(光电耦合器输出)+41 -42 低位信号输出端子(干簧管接点输出,5---11VDC, <8 mA)+51 -52 高位信号输出端子(干簧管接点输出,5---11VDC, <8 mA)调试步骤1.接通气源前,先将气源管放空一段时间以排除管路中可能存在的灰尘、杂质、水、油等。
建议放空时间30分钟,可以用手或者白纸、白布进行气源质量的检查。
声明:如由于灰尘、杂质、水、油等造成定位器的损坏,ABB将不提供质保。
检查减压阀后压力是否符合执行器的铭牌参数要求(定位器的最大供气压力为6 BAR,但实际供气压力必须参考执行器所容许的最大气源压力)。
2.接通4---20mA输入信号。
(定位器的工作电源取自输入信号,由DCS二线制供电,直接加至定位器的电压不能超过30V / 50mA,否则有可能损坏定位器电路)。
FMST PC-Link-I使用说明 金关安保
4.2 再按下设定键,LINK 如下图所示:
金关安保
参数显示 20,说明当前设定有 20 台终端与 LINK 相连接。 4.3 按参数调整键将参数调整到 28,如下图所示:
-6-
金关安保
4.4 按确定键,按巡检/(修改)键,确认此次操作,使 LINK 回到巡检状态。如下图所示:
5- 通过 LINK 对相连接的终端进行参数调整:
(以对 2 号终端的第 22 项功能进行调整,假定准入码已经输入) 5.1 在巡检状态下按巡检/(修改)键,使 LINK 进入修改状态如下图所示:
-7-
5.2 先调整地址码到 02,再调整功能码到 22,按设定键 LINK 如下图所示
金关安保
5.3 按参数调整键将参数调整到 02,并按确认键确认此次操作。结果如下图所示
3- LINK 内部说明
存储器 主芯片
电源接口:LINK 使用 24V 直流电源。 通讯接口:RS-232 与 RS-485 通讯接口端子。 报警输出接口:火警与故障输出接口 主芯片:LINK 使用的是 WINBOND 公司的 W77E58 单片机 存储器:用于存储 LINK 所记录的事件。 蜂鸣器:当有报警或故障发生是,蜂鸣器发出鸣叫。
RS232 通讯接口 消音键
附件:PC-LINK 技术参数
电源
DC 24V/ 1A ±5%
尺寸
400×250×80 ㎜
重量
2㎏
操作温度范围 0~40℃
操作湿度范围 0~90%凝结
RS232 通讯口 小于 120m 三芯 RVVP3×1.0 ㎜ 2
RS485 通讯口 小于 1.2km 二芯 RVVP2×1.5 ㎜ 2
06 快速学习 01
中控室DCS操作说明书
中控室操作说明书第一部分系统概述我公司引进的Freelance 2000集散控制系统是九十年代最先进的紧凑型集散控制系统。
它是由ABB自动化集团德国Hartman&Braun(H&B)公司研制开发的。
该系统采用了当今世界最先进、成熟的计算机技术、网络技术、控制理论技术,它集集散控制系统(DCS)和可编程控制器(PLC)的优点于一体,同时具有DCS 系统丰富的操作界面及控制能力和PLC高速的逻辑控制能力,并且有很好的兼容性和扩展能力。
该系统操作层(操作员站、工程师站)采用标准PC机,以MS—Windows NT Workstation 4.0操作系统作为运行平台;过程站采用全新的硬件,组态灵活、功能强大。
该系统还优化了工业领域广泛应用的两条总线:Diginet—P(CAN总线)用于现场通讯,具有牢固且数据传输可靠的优点;过程站及操作员站/工程师站之间通讯通过Diginet—S(以太网)系统总线,我公司选用了完全抗干扰且传输速率高的10Base—FL光纤作为传输介质,提高了系统的可靠性。
我公司的DCS系统目前由4个操作员站(OS)、1个操作员站/工程师站(OS/ES)、3个过程站(PS)组成。
过程站用来完成对全厂的模拟量及数字量的采集,经过回路控制、顺序控制、逻辑控制等运算后完成输出以对整个生产过程进行控制。
操作员站可以监视整个生产过程的工艺参数及设备状况,并通过操作介入来调节和控制生产过程;操作员站还可以浏览趋势、记录和报警等。
工程师站安转专用的工程工具,主要用于系统的配置、组态、编程与调试,可在离线和在线两种方式下工作。
第二部分画面及操作介绍一、操作员站介绍操作员站是整个系统的人—机接口,用它来完成对画面、趋势、记录及报警等的监视与操作。
操作员站的用户界面从上至下依次为报警信息行、标题行、菜单行、画面区、状态行、操作区六部分。
报警信息行位于屏幕的最上方,它总是可见的,不能被其它画面覆盖。
PMC53电表说明书
使用说明书 (PMC-53M/53I/53V)
(V3.1)
深圳市中电电力技术有限公司
PMC-53 系列三相数字式多功能测控电表
深圳市中电电力技术有限公司 Nhomakorabea危险和警告
本设备只能由专业人士进行安装,对于因不遵守本手册的说明所引 起的故障,厂家将不承担任何责任。
7 附图.................................................................................................................................................21 7.1 面板与端子图 ..........................................................................................................................21 7.2 剩余电流互感器选型与尺寸 .....................................................................................................24 7.3 温度探头选型与尺寸................................................................................................................26
2 技术指标............................................................................................................................................2 2.1 环境条件....................................................................................................................................2 2.2 额定参数....................................................................................................................................3 2.3 测量准确度指标.........................................................................................................................3 2.4 电气绝缘性能 ............................................................................................................................4 2.5 机械性能....................................................................................................................................4 2.6 电磁兼容性能 ............................................................................................................................4
精敏数字 JMDM-COM20DI工业级20路数字量输入串口控制器说明书
JMDM-COM20DI工业级20路数字量输入串口控制器说明书一、产品简介JMDM-COM20DI是深圳市精敏数字机器有限公司自主研发的一款具有高可靠稳定性的工业单片机数字量串口控制器、板载20路光电隔离数字量信号输入,可用于检测外部各种开关量信号输入,如光电传感器、红外传感器、霍尔传感器、接近开关、点动开关等数字量输入器件,产品具有如下特征:1、产品设计及品质:专业的工业级高可靠防雷击抗强电磁高频干扰电路设计、电路布局紧凑而合理、散热良好、多采用贴片式芯片及元器件,产品程序保密性高、工业品质可靠、性能稳定,可胜任各种电磁干扰大、环境恶劣的工业现场,如引弧电流、焊接电流、变频器等工作场合均可稳定使用。
2、20路光电隔离数字量输入特性:1)20路光电隔离数字量采用了光电隔离的电路设计方法,稳定可靠;2)20路光电隔离数字量输入可分成了四组,可分别用于不同的电压场合;每路数字量输入的输入电压范围为3.3V—24V;输入电流为5-10MA;3、2种通信接口可选:1个RS485接口和1个RS232接口通过短路帽可选;4、3种工作方式:支持独立控制、RS232串口监控、RS485串口监控3种方式;5、精确时间控制:自带系统时钟,可实现精确时间控制;6、系统稳定性:具有工业级防雷击、抗强电磁干扰、高可靠性能,无死机现象。
7、数字量工作状态指示灯:每路数字量输入都有一个指示灯,方便观察输入点工作状态;8、工业外壳,外观紧凑,防尘美观,一体化紧凑型设计,安装方便:导轨或螺孔安装;9、提供简单易用的串口通信协议、上位机源码,方便客户二次开发。
二、性能参数1、工作电源:控制器工作电源:12V或24V,交流或直流通用;输入工作电源:3~24V直流电;2、主控制芯片:8位高性能单片机加高速高稳定FPGA可编程阵列电路;3、程序存储空间:32K (若有特定需要,可用64K);4、数据存储空间:16K (若有特定需要,可用32K),保存数据,断电数据不丢失;5、输入:20路数字量输入,每路输入承受的最大电压为36V,最大承受电流是10MA;每路输入点均采用了光电隔离,隔离电压为1000V;出厂默认为低电平有效型(NPN型);输入点可根据客户需要订做成高电平有效型(PNP型),购买前需说明;6、系统稳定性:采用内部看门狗及严格的高频滤除特性,使系统工作稳定可靠,死机自启动时间在1ms之内;7、2种通信方式(接口)可选:1个RS232接口、1个RS485接口可通过短路帽选择。
DCS400晶闸管变流器 说明书
7 串 行 通 讯 .............................................................. 7-1
7.1 控制盘接口 .......................................................................... 7-6 7.2 RS232 接口 ......................................................................... 7-7 7.3 现场总线接口 ...................................................................... 7-8
2.1 2.2 2.3 2.4 环境条件 .............................................................................. 2-2 DCS 400 变流器模块 ........................................................... 2-3 DCS 400 过载能力 .............................................................. 2-4 DCS 400 的控制和显示 ....................................................... 2-5
6 操 作 指 导 .............................................................. 6-1
6.1 6.2 6.3 6.4 控制盘 ................................................................................. 6-2 调试向导 .............................................................................. 6-7 调试技巧 ............................................................................ 6-20 故障排除 ............................................................................ 6-24
M误码仪说明书
1.概述2M数字传输性能分析仪,适用于数字传输系统的工程施工、工程验收及日常维护测试。
其性能可靠稳定、功能齐全、体积小巧,采用大屏幕中文显示,操作简洁容易。
2M数字传输性能分析仪可对2Mbit/s接口数字通道、同向64k、RS232、RS485、RS449、、、EIA530、EIA530A、接口数字通道进行测试,具有两个2Mbit/s 接口,可同时对两条通道进行测试。
●对2Mbit/s接口数字通道可进行以下项目的测试。
中断业务误码测试在线误码测试比特误码、编码误码、帧误码、CRC误码、E比特误码性能测试图案滑动测试时钟滑动测试信号丢失、AIS告警、帧远端告警、复帧远端告警、帧失步、图案失步告警测试线路信号频率测试话路通道信号电平、频率测试信令状态显示话路通道内容显示话路通道忙闲显示直通方式环路延时测试自动保护倒换时间测试信号波形模板测试时隙内容分析、、误码性能分析双路2Mbit/s同时检测,双向监听●对RS232、RS485、RS449、、、EIA530、EIA530A、接口的数字通道可进行以下项目的测试。
中断业务误码测试比特误码图案滑动测试信号丢失告警测试线路信号频率测试环路延时测试自动保护倒换时间测试中断业务误码测试●对同向64Kbit/s接口数字通道可进行以下项目的测试。
中断业务误码测试比特误码图案滑动测试信号丢失、AIS告警线路信号频率测试直通方式环路延时测试自动保护倒换时间测试误码性能分析2、仪表外观及组成前面板①状态、告警指示灯②液晶显示器③监听扬声器④电源开关⑤操作键⑥功能键⑦光标移动键图. 前面板2.1.1 状态、告警指示灯如图,此指示灯只指示Rx1端口或DATA端口的状态。
右边的灯代表当前仪表状态,绿色灯亮表示相应的状态正常,红色灯亮表示相应的状态不正常,仪表检测到事件后红灯亮秒,若在秒内事件又出现,红灯保持常亮。
事件消失后红灯熄灭。
信号左边的黄灯来表历史告警纪录表示仪表检测到事件后灯亮,事件消失后灯仍保持亮,直至用CLR HIS清除。
FANUC OM全参数说明书
71.6 1改成0 PMC启动时读入芯片程序FANUC 0系统参数功能目录(其中:0—T或0—M栏中为0的表示该类数控机床拥有此项功能,否则不具备次功能)表1 SETTING参数参数号符号意义—T—M0000 PWE 参数写入0 0 0000 TVON 代码竖向校验0 0 0000 ISO EIA/ISO代码0 0 0000 INCH MDI方式公/英制0 0 0000 I/O RS—232C口0 0 0000 SEQ 自动加顺序号0 0表2 RS232C口参数2/0 STP2 通道0停止位0 0 552 通道0波特率0 0 12/0 STP2 通道1停止位0 0 553 通道1波特率0 0 50/0 STP2 通道2停止位0 0 250 通道2波特率0 0 51/0 STP2 通道3停止位0 0 251 通道3波特率0 0 55/3 RS42 Remote Buffer 口RS232/522 0 0 390/7 NODC3 缓冲区满0 0表3 伺服控制轴参数1/0 SCW 公/英制丝杠0 03/0.1 .2.4 ZM回零方向0 08/2.3 .4 ADW轴名称30/0. 4 ADW轴名称32/2. 3 LIN3,4轴,回转轴/直线轴388/1 ROAX 回转回转轴循环功能0 388/2 RODRC 绝对指令近距离回转0 388/3 ROCNT 相对指令规算0 788 回转轴每转回转角度011/2 ADLN 第4轴,回转轴/直线轴0 398/1 ROAX 回转轴循环功能0 398/2 RODRC 绝对指令近距离回转0 398/3 ROCNT 相对指令规算0 788 回转轴每转回转角度0860 回转轴每转回转角度0 0500—503 INPX,YZ,4到位宽度0 0504—507 SERRX,Y,Z,4运动时误差极限0 0508—511 GRDSX,Y,Z,4栅格偏移量0 0512—515 LPGIN位置伺服增益0 0517 LPGIN 位置伺服增益(各轴增益)0 0518—521 RPDFX,Y,X,4G00速度0 0522—525 LINTX,Y,Z,4直线加/减速时间常数526 THRDT G92时间常数0528 THKFL G92X轴的最低速度0 0 527 FEDMX F的极限值0 0 529 FEEDT F的时间常数0 0 530 FEDFL 指数函数加减速时间常数0 0 533 RPDFL 手动快速成移动倍率的最低值0 0 534 ZRNFL 回零点的低速0 0535—538 BKLX,Y,Z,4反向间隙0 0593—596 STPEX,Y,Z,4伺服轴停止时的位置误差极限0 0393/5 快速倍率为零时机床移动0 0表3 坐标系参数10/7 APRS 回零点后自动设定坐标系0 0 2/1 PPD 自动设坐标系相对坐标值清零024/6 CLCL 手动回零后清除局部坐标系0 28/5 EX10D 坐标系外部偏移时刀偏量的值(×10)0708—711 自动设定工件坐标系的坐标值735—728 第二参考点0 0780—783 第三参考点0 0784—787 第四参考点0 0表4 行程限位8/6 OTZN Z轴行程限位检查否0 15/4 LM2 第二行行程限位0 24/4 INOUT 第三行行程限位0 57/5 HOT3 超行程—LMX—+LMZ有效0 65/3 PSOT 回零点前是否检查行程限位0 0700—703 各轴正向行程0 0704—707 各轴负向行程0 015/2 COTZ 超行程—LMX—+LMZ有效0 20/4 LM2 第二行行程限位0 24/4 INOUT 第三行行程限位0743—746 第二行行程正向限位747—750 第二行行程反向限位804—806 第三行行程正向限位807—809 第三行行程反向限位770—773 第二行行程正向限位774—777 第二行行程反向限位747—750 第三行行程正向限位751—754 第三行行程反向限位760—763 第四行行程正向限位764—767 第四行行程反向限位表5 进给与伺服电机参数1/6 RDRN 空运行时,快速移动指令是否有效0 0 8/5 ROVE 快速倍率信号ROV2(G117/7)有效0 49/6 NPRV 不用位置编码器实现主轴每转进给0 0 20/5 NCIPS 是不进行到位检查0 0 4—7 参考计数器容量0 0 4—7 检测倍比0 021/0.1.2.3 APC绝对位置编码器0 035/7 ACMR 任意CMR 0 037/0.1.2.3 SPTP用分离型编码器0 0100—103 指令倍比CMR0 0表6 DI/DO参数8/7 EILK Z轴/各轴互锁0 09/0.1 .2.3 TFINFIN信号时间0 09/4.5 .6.7 TMFM,S,T读信号时间0 012/1 ZILK Z轴/所有轴互锁0 31/5 ADDCF GR1,GR2,DRN地址0252 复位信号扩展时间0 0表7 显示和编辑1/1 PROD 相对坐标显示是否包括刀补量0 0 2/1 PPD 自动设坐标系相对坐标清零0 0 15/1 NWCH 刀具磨损补偿显示W 0 0 18/5 PROAD 绝对坐标系显示是否包括刀补量0 23/3 CHI 汉字显示0 0 28/2 DACTF 显示实际速度0 029/0. 1 DSP第3,4轴位置显示35/3 NDSP 第4轴位置显示0 38/3 FLKY 用全键盘0 0 48/7 SFFDSP 显示软按键0 0 60/0 DADRDP 诊断画面上显示地址字0 0 60/2 LDDSPG 显示梯形图0 0 60/5 显示操作监控画面0 0 64/0 SETREL 自动设坐标系时相对坐标清零0 0 77/2 伺服波形显示0 0 389/0 SRVSET 显示伺服设定画面0 0 389/1 WKNMDI 显示主轴调整画面0 0表8 编程参数10/4 PRG9 O9000—O9999号程序保护0 0 15/7 CPRD 小数点的含义0 0 28/4 EXTS 外部程序号检索0 0 29/5 MABS MDI—B中,指令取决于G90/G91设定0 389/2 PRG8 O8000—O8999号程序保护0 0394/6 WKZRST 自动设工件坐标系时设为G54 0 表9 螺距误差补偿11/0. 1 PML螺补倍率0 0712—715 螺补间隔756—759 螺补间隔1000,2000 3000,4000 补偿基准点0 01001-1128 2001-2128 3001-3128 4001-4128 补偿值0 0表10 刀具补偿1/3 TOC 复位时清除刀长补偿矢量0 0 1/4 ORC 刀具补偿值(半径/直径输入)08/6 NOFC 刀补量计数器输入010/5 DOFSI 刀偏量直接输入013/1 GOFU2 几何补偿号(由刀补号或刀号)指定013/2 GMOFS 加几何补偿值(运动/变坐标)014/0 T2D T代码位数014/1 GMCL 复位时是否清几何补偿值014/5 WIGA 刀补量的限制015/4 MORB 直接输入刀补测量值的按钮024/6 QNI 刀补测量B时补偿号的选择075/3 WNPT刀尖补偿号的指定(在几何还是在磨损中)122 刀补偿量B时的补偿号0728 最大的刀具磨损补偿增量值0729 最大的刀具磨损补偿值078/0 NOINOW 用MDI键输入磨损补偿量0 0 78/1 NOINOG 用MDI键输入几何补偿量0 0 78/2 NOINMV 用MDI键输入宏程序变量0 0 78/3 NOINMZ 用MDI键输入工件坐标偏移量0 0 393/2 MKNMDI 在自动方式的停止时,用MDI键输入0 0工件坐标偏移量表11 主轴参数13/5 ORCM 定向时,S模拟输出的极性13/6.7 TCW,CWM S模拟M03,M04的方向0 0 14/2 主轴转速显示0 0 24/2 SCTO 是否检查SAR(G120/4)0 0 49/0 EVSF SF的输出0 0 71/0 ISRLPC 串行主轴时编码器信号的接法071/4 SRL2SP 用1或2个串行主轴071/7 FSRSP 是否用串行主轴0108G96或换档(#3/5:GST=1)或模拟主轴定向(SOR:G120/5:M=1)速度0 0110 检查SAR(G120/4)的延时时间0 516 模拟主轴的增益(G96)0539模拟主轴电动机的偏移补偿电压(G96)551 G96的主轴最高转速0 556 G96的主轴最高转速0540—543 各档主轴的最高转速3/5 GST 用SOR(G120/5)定向/换档0 14/0 SCTA 加工启动时检查SAR信号0 20/7 SFOUT 换档时输出SF 0 29/4 FSOB G96时输出SF 0 35/6 LGCM 各档最高速的参数号0539,54 1,555 各档的主轴最高转速542 主轴最高转速0 543 主轴最低转速0585,58 6 主轴换档速度(B型)577 模拟主轴电动机的偏移补偿电压0 6519/7 主轴电动机初始化0 0 6633 主轴电动机代码0 06501/2 POSC2 用位置编码器0 06501/5 -7 CAXIS1—3用高分辩率编码器0 06503/0 PCMGSL 定向方法(编码器/磁传感器)0 0 6501/1 PCCNCT 内装传感器0 06501/4 .6.7 位置编码器信号0 06504/1 HRPC 高分辩率编码器0 0表12 其它24/0 JGNPMC 用PMC 0 071/6 DPCRAM 显示PMC操作菜单0 0123 图形显示的绘图坐标系00001ADFT RDRN DECI ORC TOC DCS PROD DCS7 6 5 4 3 2 1 0 ADFT 1:进行自动漂移补偿。
单相智能仪表说明书 (1)
地址 命令 数据长度 数据段(2 字节)
01H 03H 04H
3eH f8H 51H ecH
校验码(低位在前) b5H,c9H
校验码 4aH,37H
(2) 写数据寄存器(功能代码 10H):设置电流变比 CT=80,仪表地址为 1。
主机写数据帧:
地址 命令 起始地址 数据段
校验码
01H 10H 00H,00H 00H,50H
6.设 仪 表 变 送 输 出
如仪表电流互感器是 100/5A,要让仪表从 0-80A 变送输出 4-20mA, 长按住 SET 键 5 秒不放,此时仪表显示 Ct,此时再按六下 SET 键,仪表显示 Sdt,此此时再按一下 SET 键,仪表显示默认 4-20mA 输出状态(如果要改成 0-20mA 就按一下向下键),此时再按一下 SET 按,仪表显示 SdH,此时再按一下 SET 按,仪表显示 1000,关于变送值的计算(80 除以 100 再乖 以 1000=800),此时再按向上或是向下键设好 800, 改好以后一直按 SET 键退出保存就好了
0.2 级 数码显示:4 位高亮度 LED 数码管 0-9999 工作温度:-10-55℃;储存温度:-20-75℃ 绝缘:信号、电源、输出端子对壳电阻>5MΩ 耐压:信号输入、电源、输出间>AC2KV
三、仪表外形尺寸及开孔尺寸
外型代号 5 1 D A 3 9 2
外型尺寸(mm) 96×48 160×80 48×48 72×72 80×80 96×96 120×120
0-12 0-9999 0-9999 0:4-20mA 1:0-20mA 0-1200 IE7554 格式 IE7554 格式 IE7554 格式 IE7554 格式
5
M-System产品说明书.pdf_1693882152.6449704
BEFORE USE ....Thank you for choosing M-System. Before use, please checkcontents of the package you received as outlined below.If you have any problems or questions with the product, please contact M-System’s Sales Office or representatives.■PACKAGE INCLUDES:Signal conditioner (1)■MODEL NO.Confirm Model No. marking on the product to be exactly what you ordered.■INSTRUCTION MANUALThis manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures.POINTS OF CAUTION■POWER INPUT RATING & OPERATIONAL RANGE• Locate the power input rating marked on the product and confirm its operational range as indicated below:24V DC rating: 24V ±10%, approx. 90mA■GENERAL PRECAUTIONS• Before you remove the unit or mount it, turn off the power supply and input signal for safety.■ENVIRONMENT• Indoor use.• When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation.• Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact.• Environmental temperature must be within 0 to 55°C (32 to 131°F) with relative humidity within 30 to 95% RH in order to ensure adequate life span and operation.• Be sure that the ventilation slits are not covered with ca-bles, etc.■WIRING• Do not install cables close to noise sources (relay drive cable, high frequency line, etc.).• Do not bind these cables together with those in which noises are present. Do not install them in the same duct.■AND ....• The unit is designed to function as soon as power is sup-plied, however, a warm up for 10 minutes is required for satisfying complete performance described in the data sheet.COMPONENT IDENTIFICATION INSTALLATIONUse Installation Base (model: M8BSx).TERMINAL CONNECTIONSConnect the unit as in the diagrams below . ■EXTERNAL DIMENSIONS unit: mm (inch)■CONNECTION DIAGRAM+–+–+–Input Connection Examples ■ AC Voltage PulseOutput Connection Examples■ Voltage Pulse+–+–SENSOR EXCITATIONWith the sensor excitation shortcircuited or exceeding 30 mA, the module stops feeding the power for protecting itself from overheating.In order to recover feeding, disconnect the sensor and re-connect it after removing whatever caused the overload. CHECKING1) Terminal wiring: Check that all cables are correctly con-nected according to the connection diagram.2) Power input: Check the power input voltage.3) Input: Check that the input frequency is 50 kHz or less for AC voltage pulse, 100 kHz or less for other types of input; each the same or less than the maximum output frequency.Check also that the input pulse is of 2 µsec. or wider (ex-cept for AC voltage pulse) for over 10 Hz, of 10 msec. or wider for 0 – 10 Hz.4) Output: Check that the load resistance meets the de-scribed specifications as below.OUTPUT LOAD REQUIREMENTSOpen collector 5 V voltage pulse 50 V DC @ 50 mA max.1 kΩ minimum5) Polarity SW: Push in the switch to invert the output log-ic. Push back for non-inverted output.LIGHTNING SURGE PROTECTIONM-System offers a series of lightning surge protector for protection against induced lightning surges. Please contact M-System to choose appropriate models.。
能源控制器Ⅰ型使用说明书
能源控制器Ⅰ型使用说明书青岛东软载波科技股份有限公司能源控制器类型标识代码分类说明NC X X X X-XXXX 能源控制器场景远程通信本地通信总线通信产品代号NC-能源控制器1-公变2-专变1-4G2-5G0-无1-HPLC2-微功率无线3-双模1-RS-4852-M-bus3-CAN由不大于8位的英文字母和数字组成。
英文字母可由生产企业名称拼音简称表示,数字代表产品设计序号能源控制器的功能模块类型标识代码分类见下表。
功能模块类型标识代码分类说明G X X X X-XXXX功能模块功能模块类型功能模块类型属性接口数量温度级别产品代号G-功能模块K-控制模块X-遥信模块B-本地通信模块Y-远程通信模块M-模拟量采集模块T-其他功能模块类型无补充属性,则为X;本地通信模块:Z-窄带电力线载波H-HPLCJ-微功率无线S-双模通信模块(载波&无线)M-MBUS通信模块R-RS485通信模块C-CAN通信模块T-其它信道远程通信模块:2-无线公网2G3-无线公网3G4-无线公网4G5-无线公网5GA-230MHz专网L-以太网有线网络N-公共交换电话网F-光纤有线网络T-其他信道多功能组合模块类型属性定义为:Z。
对外物理接口数量:1~9-1~9路物理接口1-C12-C23-C34-Cx由不大于8位的英文字母和数字组成,必须包含版本信息。
英文字母可由生产企业名称拼音简称表示,数字代表产品设计序号尊敬的用户:首先衷心感谢您选择青岛东软载波科技股份有限公司的产品。
青岛东软载波科技股份有限公司成立于1993年6月,2011年2月在创业板上市,现已形成以智能制造为基础,芯片设计为源头,能源互联网与智能化应用两翼齐飞的产业布局。
公司发展战略是以集成电路设计为基础,开展以融合通信为平台的技术研发;布局“芯片、软件(模组)、终端、系统、信息服务”产业链,聚焦能源互联网、智能化应用这两个战略新兴领域,打造国际一流企业。
ME模块机线控器使用说明
ME四定频线控器说明书一. 线控器面板说明1.线控器基本性能a.输入电源:12V AC±10%;功耗<1.5W。
b.通讯方式:RS-485标准串行通讯口,通讯距离可达1200m;RS-232标准串行通讯口。
(预留)c.液晶LCD:显示4行11列汉字。
d.蜂鸣器:线控器上电时发出“嘀”单声;操作按键时发出“嘀”单声;故障报警时发出“嘀、嘀、嘀”连续三声。
e.背光源:操作按键或故障报警时,背光源点亮20s。
f.LED开机指示灯:线控器操作开机时亮。
2.线控器按键说明a.【开/关机键】:该键作为系统开/关机操作键,初始状态为关机时,操作该键系统开机;每操作一次该键与上次状态求反。
b.【模式键】:该键作为系统运行模式操作键,操作该键时,系统运行模式在制冷和制热之间切换。
c.【节能键】:该键作为系统节能模式运行操作键,操作该键,系统制冷回水目标温度设为15℃,系统制热回水目标温度设为37℃。
d.【修改键】在非设定状态时,该键作为系统回水温度的设置。
e.【设定键】:该键作为进入设置参数界面的操作键,进入设置参数界面后,可进行常规设置项目(设定时间/定时模式/设定定时)和特殊设置项目。
f.【选择键】对象会反黑显示。
g.【确认键】:该键作为确认进入设置项目的操作键,操作该键时,被选中的设置项目栏进入相对应的设置参数界面。
h.【退出键】:该键作为退出(返回)操作键,每操作一次该键系统由当前界面返回上一级界面,最终返回线控器主界面。
i.【查询键】:该键作为查询模块机参数界面操作键,进入查询模块机参数界面后,通过操作性能参数及运行情况。
j.【故障键】以查询迄今为止每台模块机出现的历史故障,故障记录只保存最新的28个。
也可通过【故障键】清除历史故障记录。
3.线控器基本操作运行说明a.当需要模块机启动运行时,通过按线控器开/关机键,系统立刻按设置模式进入启动运行,同时开机指示灯点亮;b.系统运行模式一般在开机前通过模式键进行选择,也允许系统运行中进行模式切换,系统会自动停机后按新的运行模式启动运行。
美特尔 AM-33 3 3 4 数字智能一键自动DMM操作手册安全规则说明书
AM-333 3/4 DIGITS INTELLIGENT ONESWITCH AUTO DMMOPERATION MANUALSAFETY RULESλThis meter is designed and tested in accordance with IEC publication 1010, pollution degree II and installation category (overvoltage category) III 600V.λThis meter has been tested according to the following EC Directives♦89/336/EEC (EMC of Nov., 1992, Electromagnetic Compatibility)♦73/23/EEC (Product safety law of June 11, 1979, Low Voltage Directive of February 19, 1973)λThis meter is designed to be indoor use at temperature 41°F to 104°F (5°C to 40°C) and altitude up to 2,000m.λTo ensure that the meter is used safely, follow all safety and operating instructions in this operation manual. If the meter is not used as described in this operation manual, the safety features of this meter might be impaired.λDo not use the meter if the meter or test leads look damaged, or if you suspect that the meter is not operating properly.λWhen using the probes, keep your fingers behind the finger guards on the probes.λDisconnect the live test lead before disconnecting the common test lead.λMake sure power is off before cutting, unsoldering, or breaking the circuit. Small amount of current can be dangerous.λDo not apply more than 600Vdc or 600Vac rms between a terminal and earth ground.λTo avoid electrical shock, use CAUTION when working above 60Vdc or 25Vac rms.Such voltages pose a shock hazard.λNever make measurements with the battery cover or bottom case off.λTo avoid electrical shock or damage to the meter, do not exceed the input limits. INTERNATIONAL SYMBOLSImportant informationsee manual ContinuityAC GroundDC Double insulation FEATURESλOne switch operation.λAuto polarity with engineering units annunciator.λDC volt, AC volt, Resistance(4V threshold voltage to determine V or R function)λContinuity testλAuto power off with power resumeλData holdλFull range 600V overload protectionλConform to IEC1010-1 CAT III 600V3.1 General SpecificationsDisplay: 3 3/4 digit LCD, 3999 counts with decimal point andengineering units annunciator displayPolarity:Automatic, (-) negative polarity indication.Zero adjustment:Automatic.Measuring Method:Dual slop integration A to D converter system.Over range indication:Only the “OL” is displayed.Power:Single, standard 9 volt battery NEDA 1604, JIS 006P,IEC6F22.Dimension:70 (H) x 144 (W) x 40 (D) mm.Weight:Approx. 270gm. (including batteries and packaging)3.2 Electrical SpecificationsPANEL DESCRIPTIONS1) 3 3/4 digit LCD display2) Power resume button3) ON/OFF switch4) Data hold button5) Case6) Input and common terminals WARNINGOPERATION1) When measuring voltage ensure that the instrument is not connected. Always ensure thatthe correct terminals are used for the type of measurement to be made.2) Use extreme care when measuring voltage above 50V, especially from sources wherehigh energy exists.3) Avoid making connections to “live” circuits whenever possible.4) When making current measurements ensure that the circuit is not “live” before opening itin order to connect the test leads.5) Before making resistance measurements or continuity test, ensure that the circuit undertest is de-energised.6) Extreme care should be taken when using the instrument to conjunction with a currenttransformer connected to the terminals. High voltage may be produced at the terminals if an open circuit occurs.7) Ensure that the test leads and prods are in good condition with no damage to theinsulation.8) Take care not to exceed the over-load limits as given in the specifications.9) Fuse for replacement must be of the correct type and rating.5.1 DC and AC Voltage measurement1)Connect the black test lead to the “COM” socket and red test lead to the “ ” socket.2) Connect the test prods across the source or load under measurement.5.2 Resistance measurement1) Connect the black test lead to the “COM” socket and red test lead to the “ ” socket.2) Connect the prods across the circuit to be tested.CAUTION: Ensure that the circuit to be tested is “dead”.Max. input over-load : 600V rms < 30sec.5.3 Continuity test1) Connect the black test lead to the “COM” socket and red test lead to the “ ” socket.2) Connect the prods across the circuit to be tested, if the resistance less than approx. 47Ω,buzzer will be activated.5.4 Data holdA push switch is used to hold data during measurement. Pressing the key, reading is heldand “H” appears on display. Pressing the switch again to release the hold data.Note : In auto AC/DC voltage selection, if the source under test is AC, hold function willoperative only when source under test is in continuous contact with the test probes.5.5 Auto power offThe meter will turn off automatically to extend the battery life after approx. 30 minutes withoutoperation. Resume power by pressing “P. Resume” button.6. MAINTENANCECAUTIONBEFORE ATTEMPTING BATTERY AND FUSE REMOVAL OR REPLACEMENT,DISCONNECT TEST LEADS FROM ANY ENERGISED CIRCUITS TO AVOID SHOCKHAZARD.6.1 Fitting and replacing the battery1) Ensure that the instrument is not connected to any external circuit, switch off the meterand remove the test leads from the terminals.2) Remove the screw of the back case.3) Replace the spent battery with the same type.4) Reinstate the back case, tighten and securing screw.6.2 CleaningPeriodically wipe the case with a soft damp cloth and mild household cleanser. Do not useabrasives or solvents. Ensure that no water gets inside the equipment to prevent possibleshorts and damage.FOR TECHNICAL ASSISTANCE,PLEASE CONTACT:AMPROBETel : 305-423-7500Fax : 305-423-7554Technical Support : 800-327-5060!!!。
蒂森,LMS1电子板教入操作
《LMS1电子板的教入操作》1. 作业前提:1). 适用于LMS1工作程序更换/升级后2). 新板的第一次运行2. 工具和器具的准备:1). Diagnostic unit I型诊断仪2). PDA和电脑不能进行LMS1调试3). 相当于轿厢额定标称载重量110%的标准砝码或重物3. LMS1电子板教入操作步骤:1). 准备——将电梯开到上端站的下一停站平层,并在确认轿厢内没有乘客后,将机房控制柜上的检修开关拨到“1”(检修状态)。
2). LMS1电子板教入——将Diagnostic unit I型诊断仪插入LMS1电子板,地址选择为1500(闪烁),按下Diagnostic unit I型诊断仪侧边的选择按钮,这时Diagnostic unit I型诊断仪显示持续为“15bF”,再次按选择按钮直到Diagnostic unit I型诊断仪显示“bFFF”。
a. 向上推动拨轮直到Diagnostic unit I型诊断仪显示表一中“显示”例所显示的地址,按下选择按钮后,会显示相应的数据,其含义请参照表一中右侧的“说明”例中的内容,再次按下Diagnostic unit I型诊断仪侧边的选择按钮,Diagnostic unit I型诊断仪将会显示表一中相应的“修改”例的地址。
如果不需要修改“说明”的参数,请继续向上或向下推动拨轮,将跳过相应的“修改”地址,显示下一个表一中“显示”例所显示的地址。
b. 如果需要修改其中参数,请按下Diagnostic unit I型诊断仪侧边的选择按钮并结合参照表一中右侧的“说明”例中的内容进行参数选择或修改后Diagnostic unit I型诊断仪将会自动显示完成提示“FEFE”,请按下Diagnostic unit I型诊断仪侧边的选择按钮,Diagnostic unit I型诊断仪将会自动显示下一行表一中“显示”例所显示的地址。
3). 所有参数检查/设定完成后,请向下拨动拨轮直到Diagnostic unit I型诊断仪显示退回到“bF00”或“bFFF”。
DCS系统操作手册
DCS系统操作手册1、系统界面。
打开系统时,系统界面如下:上部为菜单栏,分别为“系统菜单”,“前一副”,“后一副”,“图形管理菜单”,“工程师功能菜单”,“综合功能菜单”,“历史趋势菜单”,“显示表格菜单”,“显示日志菜单”,“系统名称显示”,“报警光字牌”“系统基本属性显示框”。
菜单栏以下为报警栏,可显示10条报警,以点说明方式显示,超过10条报警时,滚动显示。
下部为状态栏,显示系统登录级别、权限位置,还有服务器属性。
中间为工作区,主要的操作、显示等工作的区域。
2、操作员系统登录打开系统进入DCS操作界面时,默认系统运行的操作权限为监视级,即只能进行观察,不可以进行任何操作,操作人员只有登录到操作员级别以上,方可进行各种操作。
登录操作员时要注意,要根据权限位置,登录操作员的用户名不同。
权限位置在系统下侧偏右端,如显示“操作员级权限1”则表示此操作员站现在权限位置为“1”,登录的级别为操作员级。
目前只设置“权限1”和“权限0”两种权限位置。
选择“工程师工程功能菜单”—>“登录”,登录界面如下:登录操作员时:,权限1对应的操作员登录的用户名为ops,没有密码。
权限0对应的操作员登录的用户名为ops0,没有密码。
登录到操作员后,可对系统进行基本操作,添加趋势,查看报警等。
3、趋势查询操作画面上有各种数据显示点,右键单击该点,选择点趋势,可查看该点的趋势画面。
注意:趋势画面是记录可以查看前推最近一次下装服务器到当前时间的点趋势。
点趋势画面如下:上侧,分别显示该点的点名,时间间隔。
时间间隔可以输入从1~60的整数,单位是秒,时间间隔是趋势曲线变化的时间率,即输入5秒,曲线5秒钟变化一次。
趋势曲线的状态可分为“跟踪”和“历史”两种状态,选择跟踪,曲线便根据时间间隔和实际数据变化而实时更新,选择历史则曲线不再变化,而点趋势画面下侧的“前推”和“后推”按钮可用,每推一次即翻一页。
趋势显示的方式分为“曲线”和“数字”两种,选择数字,则点的趋势以数据方式显示。
AIMI说明书
目 录一、概述 (1)二、主要技术参数 (2)三、型号规格 (3)四、执行机构外形及安装尺寸 (7)五、执行机构的接线 (15)六、开箱和产品的陈套性 (20)七、运输和贮存 (20)八、质量承诺 (20)一、概述AI、MI系列智能型电动执行机构是在引进产品ROTORK A、M系列电动执行机构的基础上,采用当今最先进的超大规模数字集成电路研制而成的新一代智能化、数字化、中/英文菜单显示、遥控操作的电动执行机构。
使用红外线遥控器可安全、快捷地对执行机构力矩值、限位以及其它所有控制、指示和保护功能进行设定。
本产品执行的标准代号及名称:Q/YXBM 233 -2004《ID系列智能型电动执行机构》。
1、AI、MI智能型电动执行机构的主要特点:经典的机械力矩传感器,性能稳定、工作可靠脉冲数字化的霍尔效应位移传感器精度等级高,适应性强采用超大规模的集成芯片,使执行机构具备了强大的功能提供中文、英文切换菜单。
菜单式操作,凸现了调试简单、操作方便的优点非侵入式设计——采用双密封结构、无贯通轴设计,无需打开电气端盖即可通过遥控器进行设定和调试,是防护等级IP68的绝对保证2、AI、MI智能型电动执行机构的功能:遥控器设定功能执行机构阀位指示显示功能行程限位保护功能力矩限位保护功能状态指示触点功能1)中途限位 4)执行器正在运行 7)远程控制 10)手轮操作中 13)行程中力矩跳断 2)执行器正在打开 5)就地停止 8)开阀联锁 11)开阀力矩跳断3)执行器正在关闭 6)就地控制 9)关阀联锁 12)关阀力矩跳断阀门报警功能控制系统报警指示1)过力矩报警功能 2)堵转报警功能 a 、关方向过力矩 a 、关方向堵转 b 、开方向过力矩 b 、开方向堵转 c 、全方向过力矩 c 、全方向堵转1)紧急事件(ESD)报警 2)断信号报警执行机构报警指示1)电机过热报警 3)内电源故障报警 5)内部系统故障报警 7)就地接线故障报警 2)电池电量过低报警 4)电源缺相报警 6)阀位信号掉失保护 瞬间反向保护功能就地控制电动/自保持选择功能触点方式选择功能外部联锁设置功能条件控制设置功能两线控制设置功能力矩旁路设置功能ESD超越保护功能中断设置功能附加指示触点功能3、AI、MI智能型电动执行机构的工作原理:AI、MI系列多转式智能型电动执行机构由三相异步电动机驱动,通过蜗轮蜗杆减速,带动空心输出轴转动输出转矩。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
目次1 系统概况 (1)2 系统主要功能 (2)2.1分站功能 (2)2.2主站(控制台)功能 (2)2.3系统其它功能 (3)3 系统组成 (3)4 主要技术参数 (6)4.1系统容量 (6)4.2分站技术参数 (6)4.3主站(控制台)技术参数 (8)4.4分线盒 (8)4.5多功能控制柜 (8)4.6总线电缆技术参数 (8)5 使用说明 (10)5.1分站使用说明 (10)5.2主站(控制台)使用说明 (11)5.3系统数据设置及管理 (13)6 常见故障及处理方法 (15)MDCS-I无主机共线型全数字指令扩音呼叫/对讲系统技术说明书1、系统概况MDCS-I无主机共线型全数字指令扩音呼叫系统是一种集广播呼叫、程控交换、调度指挥功能为一体的多功能生产管理通信系统,其主要特点为:1)无主机总线控制方式,分散功率放大器,系统可靠性高;2)共线型网络结构,布线方便;全系统共用一根电缆,连接在同一根电缆上的所有分站(室内型、室外型)及主站(控制台)都可随时发起或接收呼叫,互不影响,呼叫控制灵活。
3)具有普通程控交换机及调度机功能;系统中所有分站或主站(控制台)都可随时通过拨号方式呼叫另一分站(或控制台),组成全双工通话方式。
4)一根电缆上最多可有5对(10部)分站同时进行全双工通话。
5)系统中所有室外型分站都外接一扬声器,实现广播呼叫。
6)分站或主站(控制台)都具有点呼、选呼、追呼、组呼、全呼功能;主站(控制台)具有强插、强拆、监听、单/双向控制、通话录/放音等多种功能。
7)具有会议功能;三方以上的通话自动进入会议模式,会议各方均可自由发言。
8)可与外部的程控交换机、调度机等通信设备联网。
9)可与外部的计算机及其它数据端口联网。
10)可通过扩音广播方式,向全系统各站发送多种告警信号。
11)系统安装简单,扩充方便,只需从就近的电缆分线即可增加新的分站。
12)室外型分站外壳采用抗静电增强聚酯材料制成(IP65等级), 可安装于任何恶劣环境。
13)室外型分站采用感应开关结构,密封性好,无任何可动零部件、可靠性高。
键盘为全密封带夜光轻触按键。
14)分站具有抗噪声(采用DSP数字处理技术)性能, 可在115dB(A)高噪声环境下清晰通话;15)主站(控制台)采用彩色液晶显示屏汉字提示方式;设置、管理系统数据,操作简单直观。
2、系统主要功能2.1 分站功能:1)分站具有通话和指令扩音广播功能,外接扬声器可在室外大范围听到呼叫广播。
2)分站为室外型分站和室内型分站两种。
室外型分站具有手柄通话及扩音广播功能,室内型分站只具有免提通话功能。
每个分站都有一个8位编码开关。
其中低6位开关用于设置分站在该条总线上的唯一号码。
3)分站摘机(室外型分站手柄摘机,室内型分站键入“免提”)后,通过键盘直接拨号呼叫系统中的任一个分站或主站(控制台),构成二方全双工通话方式。
4)分站摘机后,可连续拨多个分站号码,组成会议通话方式。
5)分站在与对方通话期间,可再拨另一个(或几个)分站号码,构成三方或多方会议通话方式;分站可经主站(控制台)授权后,具有组呼(群呼)功能,每个分站可设置1~8个分组,每个分组号码由2~30个分站号码组成,各分组的分站号由控制台设置。
6)分站可经控制台授权后,具有全呼功能。
7)主站(控制台)调度员(或某一分站)呼叫室外型分站时,该分站的扬声器发出振铃音,此时主叫方可发出(扩音)指令,打开被叫方的扬声器,进入扩音广播状态。
被叫方如手柄摘机,扬声器立即切断,转由手柄与主叫方通话。
8)分站摘机后,可拨“9”或按“紧呼”键,直接呼叫主站(控制台)。
拨“0”或“8”(由控制台授权)直接呼叫程控交换机或调度机的分机用户。
9)分站可通过自身键盘设置本站的扩音音量及手柄(或免提)通话音量。
2.2 主站(控制台)功能:1)通过键入对应分站键或键入分站号码呼叫某一分站,构成二方全双工通话或向分站扩音广播。
2)可连续键入多个分站号码键或在通话期间再键入一个(或多个)分站键,构成三方(或多方)会议通话或扩音广播。
3)控制本区域分站的点呼、群呼、全呼操作及收、发控制和数据设置等功能;可随时向线路发起“组呼”或“全呼”指令,被呼叫的该组分站或全部分站立即打开扬声器,进行现场扩音广播,此为发布命令,分站无权回答。
4)具有一级优先功能,可对本区各分站进行强插、强拆、监听,实现无忙呼叫。
5)可与程控交换机、调度机直接完成呼入、呼出功能。
6)具有分站对程控交换机、调度机的呼入、呼出转接功能。
7)具有对系统的数据设置及管理,以及对分站呼叫功能的控制等功能。
8)由人工通过主站(控制台)发出告警。
可向总线发送事故告警、盗警、火警等三种告警信号。
2.3系统其它功能:1)具有与输煤程控计算机系统接口及其它报警系统接口。
可接收外部控制指令后由本系统向各分站发送告警信号。
2)系统外的调度或管理人员可从外部通过程控交换机或调度机接口向本系统内部分或全部分站发出指令扩音广播。
3)调度员可通过主站(控制台)的功能键操作,可对指定的通话内容录音,对指定的录音内容回放。
4)系统对事先录音内容向线路发出扩音广播。
5)系统可对各分站自动循环测试,记录并显示测试结果,对出现故障的分站,发出提示告警信息。
3、系统组成呼叫系统可根据电厂规模、管理方式和使用要求,选用不同的网络配置方案:3.1 单区网络(图1)由一个主站(分区控制台)、若干个(最多64个)分站、分线盒、多功能汇接柜及总线电缆可组成一个单区网络;这种结构适合于规模较小的电厂或电厂的某个车间(如燃料车间)。
1)单区网络可以独立运行,外线可直接接入多功能汇接柜。
2)单区网络的主站(分区控制台)配置有二个调度员座席。
3)单区网络的分站号为三位,起始号为“201”,末尾号为“263”。
图1 单区系统示意图3.2 带有中心主站(中心控制台)的多区网络(图2)这种网络用于规模较大的系统。
全厂按照各个较为独立的生产部门(如:机、炉、电、输煤、化学等车间)分成若干个区。
中心主站(中心控制台)可设置在全厂的生产调度中心,每个区的主站(分区控制台)为各个区的调度中心,可设置在车间的集控室,其他运行岗位设置分站。
各区可独立通信,也可通过中心主站(中心控制台)进行跨区通信。
1)系统可由四个分区组成,每个分区为一条总线电缆,每条总线电缆最多可接64个分站;系统最多可接256个分站。
2)每个分区由室外型分站、室内型分站(可选)、分线盒、多功能汇接柜、分区控制台及总线电缆组成。
3)每个分区可以独立运行,外线可直接接入多功能汇接柜。
4)若系统较大,由多条总线组成时,需设置中心主站(中心控制台);此时分区主站(分区控制台)可以设置,也可以不设。
5)分区主站(分区控制台)或中心主站(中心控制台)接入多功能汇接柜,其结构、功能及接入方法基本相同。
6)分区主站(分区控制台)及中心主站(中心控制台)结构及功能相同,每个控制台配置二个调度员座席。
7)系统的分站号为三位,首位号为总线号加“1”,即“2”~“5”;后二位为该余总线的物理号:“01”~“ 63”。
如第一条总线的起始号为“201”,末尾号为“263”;第二条总线的起始号为“301”,末尾号为“363”;依此类推。
4、主要技术参数4.1 系统容量单区网络系统最多可挂64个分站;多区网络系统(四个分区)最多可挂64×4个分站。
4.2 分站技术参数4.2.1 输入和输出电平(室外型分站)1) 发信: 手柄MIC(送话器)端输入-20dB, 外线端输出电平≥+4dB 。
( 外线端终端阻抗47Ω,失真度≤5% )2) 收信: 外线输入+5dB, 手柄耳机端输出≥-6dB 。
( 耳机端终端阻抗100Ω, 失真度≤5% )3) AGC(自动增益控制)范围手柄MIC输入-35dB~-5dB, 外线端输出电平变化≤4dB 。
4)频率响应300Hz~4000Hz, ±1.5dB 。
5)送话器抗噪声性能在环境噪声为115dB(A)时,通话语音清晰。
6)功率放大器室外扬声器功放最大输出不失真功率≥30W,阻抗4Ω~16Ω,非线性失真≤3%。
7)消耗功率在无任何信号输出时,分站的静态功耗≤0.1VA 。
在功率放大器满功率输出时,分站的最大功耗≤50VA 。
8)电源频率:50H z,允许偏差-6%+2% ;电压:220伏交流,允许偏差±10% 。
9)使用环境气候环境条件:-40℃~+40℃,相对湿度5%~95% 。
10)机械环境条件振动:10m/s2, 10Hz~150Hz;冲击:100m/s2, 11ms。
11)外形尺寸及重量(以下尺寸不包括安装脚)尺寸:360mm(高)×245mm(宽)×190mm(厚);净重:11Kg 毛重:11.5Kg。
4.2.2 输入和输出电平(室内型分站)1) 发信: MIC(送话器)端输入-20dB, 外线端输出电平≥+4dB 。
( 外线端终端阻抗47Ω,失真度≤5% )2) 收信: 外线输入+5dB, 喇叭输出≥-6dB 。
( 喇叭端终端阻抗100Ω, 失真度≤5% )3) AGC(自动增益控制)范围MIC输入-35dB~-5dB, 外线端输出电平变化≤4dB 。
4)频率响应300Hz~4000Hz, ±1.5dB 。
5)送话器抗噪声性能在环境噪声为115dB(A)时,通话语音清晰。
6)功率放大器室内扬声器功放最大输出不失真功率≥3W,阻抗4Ω~16Ω,非线性失真≤3%。
7)消耗功率在无任何信号输出时,分站的静态功耗≤0.1VA 。
在功率放大器满功率输出时,分站的最大功耗≤5VA 。
8)电源频率:50H z,允许偏差-6%+2% ;电压:220伏交流,允许偏差±10% 。
9)使用环境气候环境条件:-40℃~+40℃,相对湿度5%~95% 。
10)机械环境条件振动:10m/s2, 10Hz~150Hz;冲击:100m/s2, 11ms。
11)外形尺寸及重量(放桌上)尺寸:×mm(高)××mm(宽)××mm(厚);净重:×Kg 毛重:×Kg。
4.3 主站(中心控制台或分区控制台)技术参数1)主站(中心控制台或分区控制台,技术参数相同):双席(含麦克免提对讲)。
2)功耗: ≤10W。
3)使用环境:+5℃~+40℃,相对湿度5%~85% 。
4)尺寸:500mm(长)×390mm(宽)×150mm(高),净重:15Kg。
5)工作电压(-48V)由多功能控制柜提供。
6)一条通信电缆(7对)引至多功能控制柜。
4.4分线盒(IP65)尺寸:90mm(厚)×160mm(宽)×160mm(高) ,净重:3Kg。