双板止回阀的安装要求
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
BEST PRACTICE VALVE INSTALLATION
PINS TO BE VERTICAL
VERTICAL PIPE WITH FLOW DOWN UP TO & INCLUDING 8”WITH STANDARD SPRING
VERTICAL PIPE WITH FLOW UP
HORIZONTAL PIPE
5 DIAMETERS MINIMUM FROM REDUCER/EXPANDER TO VALVE
AFTER VALVE TO REDUCER
2 DIAMETERS MINIMUM FROM VALVE TO VALVE
2 DIAMETERS MINIMUM AFTER VALVE TO BEND
Check valve should be installed a minimum of 5diameters downstream of a reducer/expander to ensure that the valve is in laminar and not turbulent flow.
Piping components such as pumps, compressors, valves, reducers, bends, elbows, orifice plates, all create turbulent flow. To maximise the life of a check valve, any type of check valve, it should be installed as detailed below to ensure the valve is in non-turbulent flow.
For non-horizontal flow directions, specific system dynamics will be required. Refer to Goodwin.
Check valves should be installed a minimum of 5 diameters upstream of a reducer or bend to avoid choked flow
preventing full opening of the check valve.
Goodwin Check Valve
2 DIAMETERS MINIMUM AFTER VALVE TO BEND
35