ICP-MS法测定长白山天然矿泉水中18种微量元素的含量

合集下载

ICP-MS_法同时测定生活饮用水中18_种元素

ICP-MS_法同时测定生活饮用水中18_种元素

分析检测ICP-MS法同时测定生活饮用水中18种元素黄伟声,黄叶薇,吴思林(北海市供水有限责任公司,广西北海 536000)摘 要:本文采用电感耦合等离子体质谱法同时测定生活饮用水中As、Se、Pb、Cd、Be、Mo、Ni、Ag、Sb、Tl、Na、Al、Fe、Mn、Cu、Zn、B和Ba。

18种元素的检出限在0.004 0~6.060 0 μg·L-1,均符合各元素标准最低限值要求,线性范围宽,线性关系好,相关系数均大于0.999 5。

测定18种元素的相对标准偏差为0.30%~3.95%,各元素的加标回收率为89.5%~108.0%。

结果表明该方法简便高效、灵敏度高、重现性好,适用于饮用水中18种元素的同时测定。

关键词:电感耦合等离子体质谱;生活饮用水;元素Simultaneous Determination of 18 Elements in Drinking Waterby ICP-MSHUANG Weisheng, HUANG Yewei, WU Silin(Beihai City Water Supply Co., Ltd., Beihai 536000, China)Abstract: Inductively coupled plasma mass spectrometry was used to simultaneously determine As, Se, Pb, Cd, Be, Mo, Ni, Ag, Sb, Tl, Na, Al, Fe, Mn, Cu, Zn, B and Ba in drinking water. The detection limit of 18 elements is 0.004 0~6.060 0 μg·L-1, all meeting the minimum limit requirements of each element standard. The linear range is wide, the linear relationship is good, and the correlation coefficient is greater than 0.999 5. The relative standard deviation for the determination of 18 elements is 0.30%~3.95%, and the recovery rates for each element are 89.5%~108.0%. The results indicate that this method is simple, efficient, sensitive, and reproducible, and is suitable for the simultaneous determination of 18 elements in drinking water.Keywords: inductively coupled plasma mass spectrum; drinking water; element《生活饮用水卫生标准》(GB 5749—2022)中常规指标和非常规指标有金属和类金属指标18项,即砷、硒、铅、镉、铍、钼、镍、银、锑、铊、钠、铝、铁、锰、铜、锌、钡和硼[1]。

ICP-AES法同时测定天然饮用矿泉水中Li等19种元素

ICP-AES法同时测定天然饮用矿泉水中Li等19种元素

ICP-AES法同时测定天然饮用矿泉水中Li等19种元素
袁雪芬;郑俊荣;唐忠宁;王雅琴
【期刊名称】《中国公共卫生》
【年(卷),期】1999(15)8
【摘要】随着人们生活水平的提高,矿泉水已成为日常生活中必不可少的纯天然饮料。

由于矿泉水中含有大量的矿物盐类和多种微量元素,与人体健康有着密切关系。

测定其含量是矿泉水质量评价的重要指标之一。

传统的化学方法如原子吸收法和摄谱的发射光谱法分析速度、灵敏度均不能满足...
【总页数】2页(P727-728)
【关键词】矿泉水;微量元素;锂;测定;ICP-AES法
【作者】袁雪芬;郑俊荣;唐忠宁;王雅琴
【作者单位】辽宁省卫生防疫站;辽宁省盖州市卫生防疫站;沈阳市自来水供水公司三水厂
【正文语种】中文
【中图分类】TS275.1
【相关文献】
1.ICP-AES法测定饮用天然矿泉水中微量钡 [J], 单晓莹;张世涛;胡金楠
2.ICP-AES测定饮用天然矿泉水中10种微量元素 [J], 张利民;杨丽君;张吉才;辛长波
3.ICP—AES法同时测定饮用天然矿泉水中锶等22种微量元素的探讨 [J], 徐卫红;
张化仁
4.ICP-OES测定饮用天然矿泉水中23种元素含量 [J], 王利华;钟跃汉;钟启升
5.ICP-AES法同时测定饮用天然矿泉水中22种元素 [J], 吴晓芳;张晶
因版权原因,仅展示原文概要,查看原文内容请购买。

ICP-MS微量元素检测

ICP-MS微量元素检测

ICP-MS微量元素检测微量元素,如砷、铬、镉、铜、铁、汞、镍、铅和钼等,虽然在生物体中的含量很少,但是它们对生物的生长、发育和生理功能是必不可少的。

尽管它们的含量很小,但缺乏或超量摄入这些元素都可能对健康产生不良影响。

铜、铁和钼是生命活动中必需的,但超过一定浓度可能是有毒的。

铬、铅和砷都是已知的致癌物质,而汞对神经系统有害。

由于它们的生物活性和潜在毒性,监测和了解这些元素在环境和生物体中的含量变得至关重要。

电感耦合等离子体-质谱法(Inductively Coupled Plasma-Mass Spectrometry,ICP-MS)是一种可以同时测定很多元素的无机质谱技术,其通过将单质离子按照质荷比的不同进行分离和检测,被广泛应用于样品中元素的识别和浓度测定。

ICP-MS 可以用于样品中一个或多个元素的定性、半定量和定量分析,测定的质量范围为3-300原子单位,分辨能力小于1原子单位,能测定周期表中90%的元素,大多数检测限在0.1-10ug/mL范围且有效测量范围达6个数量级,标准偏差为2%-4%,每个元素测定时间10秒,非常适合多元素的同时测定分析。

ICP-MS微量元素检测。

百泰派克生物科技(BTP)依托高精度电感耦合等离子体-质谱仪,根据微量元素检测原理,开发了ICP-MS微量元素检测平台,并通过CNAS/ISO9001双重质量认证体系,可高效、精准的对多种微量元素如砷、铬、镉、铜、铁、汞、镍、铅和钼等进行定性、定量检测,可同时测定多种微量元素,为元素分析提供灵活可靠的解决方案,欢迎免费咨询!ICP-MS微量元素检测技术优势1)检测范围广:可实现绝大多数金属元素和部分非金属元素的高精度检测,且能够提供同位素的信息;2)检测限高:1*10-5(Pt)~159(Cl)ng/mL;3)分析速度块:>20 samples per hour;4)精度好:RSD<5%;5)离子源稳定:优良的长程稳定性;6)应用范围广:广泛应用于地质、环境、冶金、生物、医药、核工业等领域。

ICP-MS法测定野生及种植北五味子中的微量元素

ICP-MS法测定野生及种植北五味子中的微量元素

0 引 言
五 味 子 ( c i n r hn ni Tu c)B i) S hs d a ie ss( rz al a c 1 为 木 兰 科 植 物 五 味 子 的 干 燥 成 熟 果 实 , 称 “ 五 俗 北
用 ] 可 治 疗 肺 喘 虚 咳 、 悸 失 眠 等 疾 病 . 年 , 心 ]近
(An l ss n n p cinCe tr,Y n in Un v riy,Y n i 1 3 0 ,C ia ) a y i d I s e to ne a a ba ie st a j 0 2 h n 3
Abta t sr c :T he c nt nt t a e lm e s n he i a d o e of r c ee nt i t w l d n pl n e Sc s dr c ne i (Tur z) Ba l a td hian a hi nss c il e e w r d t r i d by I duci e y Cou e a m a M a s Sp c r e r ( CP— M S) The xpe i e a e uls s ow e e e m ne n tv l pld Pls s e tom t y I . e rm nt lr s t h d
第 3 7卷 第 3期 21 0 1年 9月
延 边大学学报( 自然 科 学 版 )
J u n l fYa b a ie st ( t r lS i n e o r a o n in Un v r iy Na u a ce c )
Vo1 7 N O .3 .3 Se . 2 p 011
量 均 低 于 种植 五 味 子 . 关 键 词 : C — ; 味 子 ;微 量 元 素 I P MS 五 中 图 分 类 号 : 8 . R2 4 2 文献标识码 : A

采用ICP—MS法同时测定饮用水中多种元素效果分析

采用ICP—MS法同时测定饮用水中多种元素效果分析

采用ICP —MS 法同时测定饮用水中多种元素效果分析摘要:水作为生命之源,与大众日常生活息息相关。

保证饮用水安全成为近些年重点关注内容,饮用水污染中常见的污染物以重金属及类金属元素为主,这也成为当前试验测定的主要对象。

如今分光光度法、原子吸收光谱法等在饮用水检测中发挥重要作用,但这些方法更多适宜对单个元素进行分析,且检测周期较长、操作较为繁琐复杂。

ICP-MS法可以同时对多个元素进行检测,具备高灵敏度和精准性,因此,该方法逐渐取代其他方法,成为饮用水中多种元素测定的常用方式。

基于此,探究ICP-MS法测定饮用水中多种元素的效果有实际价值。

关键词:电感耦合等离子体-质谱法;饮用水;试验分析;多种元素测定1ICP—MS法阐述ICP-MS全称是电感耦合等离子体-质谱法(Inductively coupled plasma-Mass Spectrometry)。

其是一种将ICP技术和质谱技术融合在一起,发挥优势的分析方法。

自从该技术面世之后,在化工、材料、生物等领域得到广泛认可。

随着时代发展,该技术优势在更多领域得到展现,凭借制样简单、扫描速度快、周期短等优势,在样品检测分析领域也得到关注[1]。

该方法擅长分析金属元素,检测限可以达到PPT(10的负12次方)级,与电感耦合等离子体发射光谱法(ICP-OES)和原子吸收光谱法(AAS)相比,检测限最低,且一般情况下,每个元素测定时间只需要10s,在多元素同时检测中具备显著优势。

2试验分析2.1样品及样品预处理本实验选取了娃哈哈桶装水、实验室自来水作为测试样品。

在进行试验之前,对其进行预处理:往水样中加入硝酸,促使水样酸化至PH低于2,对于浑浊的水样进行过滤,采用0.45的滤膜进行过滤,过滤之后,仍然用硝酸酸化至PH低于2。

完成上述操作之后,借助电感耦合等离子体-质谱仪直接进样,外标法定量。

2.2实验仪器主要应用仪器为ICP-MS仪和微波消解仪,除此之外,还需要分析天平、超纯水机、微量移液器和HPDE瓶提供助力。

长白山区野生、种植贝母和白术中微量元素的ICP-MS对比分析

长白山区野生、种植贝母和白术中微量元素的ICP-MS对比分析
文献标识码 : A 文章编号 :10 -5 3 2 0 )516 —3 0 00 9 (0 8 0 —1 50 器为 An i n 0 L・ n P A Mir lw b l e; gl t 0 e 1 mi F coFo Ne ui r 石 z
中图分类号 : 5. 06 7 3
引 言
长 白 山区野 生 、种植 贝 母 和 白术 中微量 元 素 的 I P MS对 比分析 C—
姚艳红 许桂花 张敬东 李承 范 , , , , 李东浩
1 延边大学分析测试 中心 , . 吉林 延吉
2 延边大学理学 院, . 吉林 延吉
130 302
1 30 302


用 I PMS对长白山区野生 、 C- 种植 的贝母 和白术 中草药 中 C , e Z ,Mg u F, n ,Mn r C , o, e ,S , r C S ,
灰化法 :准确 称取样 品 0 500g于瓷坩 埚 中,小 心在 . 0 电炉上加热至无黑烟 ,放人 5 0℃马弗炉 中灼烧 3 n 取 5 0mi, 出, 冷却 , 1: 用 1硝酸浸出 , 转移至 2 0mL容量瓶 中定 容。 5
美国 A get 50 电感耦 合等 离子体 质谱 仪 ; n in 0 型 l 7 雾化
平均结果见表124样品加标回收率实验进行样品测定的同时对样品进行了加标回收率实验结果见表225样品的测定准确称取干燥的野生和种植的贝母白术样品05000g选用微波消解法处理样品消化后用icpms在选定的实验条件下进行测定测定平均结果见表3tame1resulbqaqcgggn7table2recoveriesatractylodes1tgg1n273结束语利用icpms测定了中草药贝母和白术中的微量元素方法准确度精密度灵敏度较高并且可以同时测定多种元素方法的rsd485行7回收率为

ICP-MS半定量法快速测定饮用水中的多种金属元素

ICP-MS半定量法快速测定饮用水中的多种金属元素
20世纪90年代兴起的电感耦合等离子质谱分析技术(ICP-MS),是近几十年发展最快的无机微量及痕量元素分析技术之一,可以同时检测样品中多种元素的含量[3-9]。它具有检出限低、动态线性范围宽、精密度和准确度高的特点,并能实现多元素同时快速测定,已经成为多个行业进行元素分析的得力工具,除了能进行常规定量分析外,还因为与质谱连用而拓展了许多新功能,其中半定量分析(semi-quantitative analysis)作为ICP-MS所特有的一项实用功能,仅需要一种或几种标准物质溶液即可实现对完全未知的样品中金属元素的测定。
Abstract: ICP-MS semi-quantitative analysis technology was used to select the total mass number scanning method for rapid qualitative analysis and rough quantitative analysis of trace elements in drinking water. The method is simple, fast and not limited by the standard material. The relative error between the measured value and the standard value is less than (+30%). The results show that the method is universal and can be used to determine many metal elements quickly and accurately at the same time. The recovery rate in various drinking water can be maintained at 65%~130%. This method can play an important role in water quality screening and detection, and provide a more detailed and comprehensive scientific basis for drinking water safety assessment.

电感耦合等离子体质谱法(ICP-MS)测定天然矿泉水中16种元素

电感耦合等离子体质谱法(ICP-MS)测定天然矿泉水中16种元素
分析检测 Analysis and Testing
doi:10.16736/41-1434/ts.2019.21.057
电感耦合等离子体质谱法(ICP-MS) 测定天然矿泉水中 16 种元素
Determination of 16 Elements in Natural Mineral Water by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
Key words:Mass spectrometry; Mineral water; Element 中图分类号:R123.1
作者简介:李 谦(1974—),女,本科,高级工程师;研究方向为食品科学及食品安全检测。
178 / 现代食品 XIANDAISHIPIN

Analysis and Testing 分析检测
关键词:质谱法;矿泉水;元素
Abstract:An ICP-MS method was developed for the simultaneous determination of 16 elements in mineral water. The water samples were acidified, and the interference of ions in the water was eliminated by automatic tuning, kinetic energy discrimination (KED) mode of He collision reaction tank and internal standard correction. Select 45Sc, 72Ge, 115In as internal standard elements.This method has the advantages of good linear correlation, low detection limit, good repeatability and good standard recovery, and can be used for the determination of limited index elements, limiting index elements and main cations in natural mineral water. By using this method, it is found that the mineral water of 8 brands contains various elements such as sodium, magnesium, potassium, calcium, barium and strontium. The contents of potassium, calcium, sodium and magnesium are high. And the element content of the limit index is very low, even not detected, all meet the requirements of GB 8537-2008; All the boundary index elements meet the requirements of GB 8537-2008. Natural mineral water is rich in trace elements, daily drinking, can be used as an effective way to supplement trace elements for the human body.

ICP-MS 测定水中16 种元素

ICP-MS 测定水中16 种元素

ICP-MS 测定水中16 种元素摘要:建立电感耦合等离子体质谱法测定生活饮用水中16 种元素的方法。

以Sc、Ge、In、Bi做内标,采用电感耦合等离子体质谱法(ICP-MS)测定水中16元素,即钾、钠、钙、镁、铁、锰、铜、锌、铬、铅、镉、钡、钼、镍、铝、砷。

对检出限、线性范围、精密度、加标回收率有关的方法学进行了研究。

测定结果表明,该方法的线性范围宽,线性相关系数均大于0.999。

测定16种元素的相对标准偏差均低于5.0%。

各元素的加标回收率均在87.6%~119.0%。

测定GSBZ-5009-88, GSB07-1375-2001, GSBZ 50019-90的标准参考物,测定值均在标准范围内。

实验结果表明:该方法简单、快速、灵敏、准确,适用于饮用水、水源水中16种元素的同时测定。

关键词:电感耦合等离子质谱;饮用水;元素与传统无机分析技术相比,电感耦合等离子体质谱(ICP-MS) 技术因其具有最低的检出限,最宽的动态线性范围,干扰少,分析精密度高,分析速度快以及检测模式灵活多样等特点,广泛应用于环境、医学、生物、半导体、冶金、石油、核材料分析等领域[1] 。

本研究采用电感耦合等离子体质谱法(ICP-MS) 测定生活水、井水中的16 种元素,采用标准工作曲线,在线内标校正和干扰方程校正,无需稀释,一次进样,可同时快速准确灵敏地测定水中的多种元素。

方法的线性范围、检出限、精密度、加标回收率以及标准参考物测定均取得良好的结果。

1. 实验部分1.1 仪器与试剂电感耦合等离子体质谱仪。

超纯水:电阻率18.2M Ω/cm;硝酸(C20=1.42g/mL);混合标准储备液:钾、钠、钙、镁、铁(C=1.0g/L),锰、铜、锌、铬、铅、镉、钡、钼、镍、铝、砷(C=0.01g/L);混合标准使用液:钾、钠、钙、镁、铁(C=0.1g/L),锰、铜、锌、铬、铅、镉、钡、钼、镍、铝、砷(C=1.0mg/L);质谱调谐液:Li、Y、Ce、Tl、Co(C=10μg/L);内标溶液:Sc、Ge、Y、In、Tb、Bi(C=0.01g/L),使用前用1%的HNO3 稀释为C=1μg/L。

ICP_MS法测定水和废水中微量金属元素方法验收_陈会明

ICP_MS法测定水和废水中微量金属元素方法验收_陈会明

收稿日期: 2017 - 07 - 31; 修订日期: 2017 - 09 - 05 作者简介: 陈会明( 1986 - ) ,女,工程师,从事环境监测工作。
第5 期
陈会明等: ICP-MS 法测定水和废水中微量金属元素方法验收
·683·
准确度进行方法验证。
2. 1 方法检出限
1 实验部分
实验室内以实验室纯水为空白样品,加入一 定量的标准溶液配制空白加标样品,配制成含 15
铜、锰、钼、镍、铅、锑、铊、钒、锌混标( Agilent Technology,产品批号: 5183-4682) 。
MDL = t( n - 1,0. 99) × S
( 1)
式中: MDL 为方法检出限; n 为样品的平行测定次
2 结果讨论与分析
数; t 为自由度为 n - 1,置信度为 99% 时 t 分布 ( 单侧) ; S 为 n 次平行测定的标准偏差。0. 004Fra bibliotek0. 01
0. 01
0. 04
镍 Ni 0. 119 0. 120 0. 108 0. 110 0. 113 0. 115 0. 102 0. 112
0. 006
0. 02
0. 04
0. 08
铅 Pb 0. 310 0. 321 0. 316 0. 316 0. 300 0. 316 0. 313 0. 313
0. 002
0. 005
0. 01
0. 02
钒 V 0. 083 0. 076 0. 094 0. 078 0. 087 0. 093 0. 083 0. 085
0. 007
0. 02
0. 05
0. 09
锌 Zn 1. 018 1. 008 0. 976 0. 946 1. 112 1. 104 0. 972 1. 019

ICP—MS法测定生活饮用水中11种元素的含量方法研究

ICP—MS法测定生活饮用水中11种元素的含量方法研究

ICP—MS法测定生活饮用水中11种元素的含量方法研究作者:倪明龙来源:《中国科技纵横》2016年第16期【摘要】采用ICP-MS法同时检测生活饮用水源水中铁、锰、铜、锌、砷、硒、镉、铅、铝、银、铊11种元素,实验结果表明该方法线性范围宽,检出限低,范围为0.00072~1.20μg/L,重现性好,RSD【关键词】 ICP-MS 重金属生活饮用水源水为了配合环保部对全国环保重点城市集中式饮用水水源水质监测的最新要求,开展109项指标全分析份工作,尤其对水质有机物、稀有重金属等方面加大检测力度,其中铁、锰、铜、锌、砷、锡、镉、铅、铝、银、铊是80项特定项目中的规定项目[1,2]。

金属的测定方法一般有化学分光光度法、原子荧光光谱法(AFS)、原子吸收分光光度法(AAS)、电感耦合等离子体质谱法(ICP-MS)、电感耦合等离子体原子发射光谱法(ICP-0ES) [3,4]等,但是化学分光光度法、及AAS法和AFS法只能进行单一元素或者双元素逐个分析,分析速度慢,前处理过程比较麻烦,无法满足痕量元素分析;ICP-OES可以进行多个元素分析,不足是检出限比较高,灵敏度较低[5,6],ICP-MS是近年来兴起的一种快速微量元素测定方法,其灵敏度高,耗时短,精密度高,可以进行多个元素的快速分析,越来越多的检验机构使用该方法进行金属检测。

本文采用ICP-MS法测定了饮用水中的铁、锰、铜、锌、砷、锡、镉、铅、铝、银、铊11种元素,通过一系列实验验证,证明该方法效果良好。

1 实验部分1.1 主要仪器与试剂Agilent电感耦合等离子体质谱仪7500a,移液枪10-100微升和100-1000微升各一支及枪头若干,纯硝酸(MOS级),Milli-Q超纯水,电阻率≥18.2(ΜΩ.cm), 10 ppb Li(7)、Co (59)、Y(89)、Ce(140)、Tl(205)调谐液,国家钢铁研究总院或国家标物中心配制的11种元素的单元素标准溶液。

利用ICP-MS法测定水质9种元素方法分析

利用ICP-MS法测定水质9种元素方法分析

利用ICP-MS法测定水质9种元素方法分析发布时间:2021-11-11T07:56:44.760Z 来源:《科学与技术》2021年23期作者:孔奕瞳[导读] 从各元素的测定结果来看,线性范围为0~100μg/L,检出限在0.003~0.720μg/L之间,平均回收率能够达到88~112%,相关系数均能达到0.9992以上。

由此可见,方法能够用于对饮用水中多种元素进行同时测定,体现准确、可靠、灵敏等诸多特点。

孔奕瞳中国石油乌鲁木齐石化公司炼油厂化验室,新疆省乌鲁木齐市 830000摘要:对饮用水进行测定,需做到对多种元素进行同时准确检测。

采用ICP-MS法检测水样,对水质钙、铁、锌、磷、硅、汞、铜、铅、锰9种元素进行测定,通过优化仪器操作条件和添加内标元素校正干扰效应。

从各元素的测定结果来看,线性范围为0~100μg/L,检出限在0.003~0.720μg/L之间,平均回收率能够达到88~112%,相关系数均能达到0.9992以上。

由此可见,方法能够用于对饮用水中多种元素进行同时测定,体现准确、可靠、灵敏等诸多特点。

关键词:ICP-MS法;水质监测;元素测定引言:随着经济的快速发展,地表水和地下水均发生了不同程度的污染。

加强水质监测,能够确定饮用水的污染情况,确保饮用水安全、卫生。

实际开展水质监测工作,需要对大量的金属和非金属元素进行测定,其中包含较多痕量元素,对测定方法提出了较高要求。

如针对饮用水地、动物保护区水源地等重要水功能区进行水质监测,需要达到更高的精确度和安全性要求。

ICP-MS法为电感耦合等离子体质谱法的缩写,属于近年来发展较快的无机痕量元素分析技术,相较于传统的分光光度法、原子吸收光谱法等具有更高灵敏度和较宽线性范围,可以实现多元素同时快速测定,能够用于对钙、铁、锌、磷、硅、汞、铜、铅、锰9种元素进行测定,为水质状况监测提供技术支撑。

1ICP-MS法分析在现代物理和化学分析领域,ICP-MS属于重要的元素检测工具,在低浓度和同位素丰度样品测定方面体现出了诸多性能优势,目前在工业、医药等多个领域应用广泛[1]。

ICP-MS测定水中25种元素方法的建立

ICP-MS测定水中25种元素方法的建立

ICP-MS测定水中25种元素方法的建立发布时间:2021-11-16T02:18:23.932Z 来源:《科学与技术》2021年8月23期作者:欧小蕾[导读] 本论文旨在建立运用电感耦合等离子体质谱技术同时检测水中25种元素含量的方法。

欧小蕾湛江市粤海水务投资集团有限公司生产部水质检测中心广东湛江 524032摘要:本论文旨在建立运用电感耦合等离子体质谱技术同时检测水中25种元素含量的方法。

除铍、硼两个待测元素运用No gas调谐模式,其余23种待测元素均运用He模式消除测定中的质谱干扰,同时应用在线添加内标液的形式校正非质谱干扰,提高测定方法的灵敏度和准确度。

本实验所测25种待测元素质量浓度线性关系较好,标准曲线相关系数R在0.9994~1.0000。

本方法建立的水中25种待测元素的检出限为0.00127~7.58μg/L,相对标准偏差RSD%在0.2%~4.6%,三个不同加标浓度水平下测试的水样平均加标回收率为87.5%~129%。

本实验所建方法具有线性范围宽,较高的灵敏度、精密度和准确度,满足水中25种元素痕量检测和定量分析的要求。

关键词:电感耦合等离子体质谱法;水样;25种元素;检出限;精密度实验;加标回收;痕量检测;定量分析The Establishment of Detective Method in Determination of 25 Elements in Water by using ICP-MSAbstract:This article aimed at establishing the detective method in determination of Be, B, Na, Mg, Al, K, Ca, Ti, V, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Mo, Ag, Cd, Sb, Ba, Tl, Pb, Hg in water samples by using ICP-MS. In order to improve the sensitivity and accuracy of the method, Be and B both use the No gas tuning mode while the rest of 23 elements using the He kinetic energy discrimination(KED) to eliminate the mass spectral interference, along with the on-line addition of internal standard mix to correct the non- mass spectrum interference. The mass concentration of 25 elements had good relationship with the linearity, the linearly dependent coefficients were between 0.9994~1.0000. The detection limits of 25 elements were 0.00127~7.58μg/L and the relative standard deviation(RSD) were between 0.2%~4.6%. Meanwhile the standard recovery rates in three different adding concentrations were 87.5%~129%. This method has wide linear range, high sensitivity, precision and accuracy, which can meet the requirements of trace detection and quantitative analysis of 25 elements in water samples.Keywords:ICP-MS; water samples; 25 elements; detection limits; precision test; adding standard recovery; trace detection; quantitative analysis 1.引言近年来,我国经济快速发展,工业废水排放急剧增加,使水污染越来越严重,水体中金属元素的含量是影响人体健康的因素之一。

ICP_MS法测定矿泉水中15种元素含量的不确定度分析_顾妍丽

ICP_MS法测定矿泉水中15种元素含量的不确定度分析_顾妍丽

[ 作者简介 ] 顾妍丽 ( 1986 -) , 女 , 本科 , 主要从事理化分析 。
中国卫生检验杂志 2010年 9 月 第 20卷 第 9期 C h i n e s e J o u r n a l o f H e a l t hL a b o r a t o r y T e c h n o l o g y , S e p2010; V o l 20 N o9 表 2 各元素工作曲线回归方程及相关系数 元素 A l M n F e N i C u Z n S r A g C d S b B a P b A s C r S e 质量数 27 55 57 60 63 66 88 109 111 121 137 208 75 52 78 斜率 b 6645. 65 17827. 50 345. 83 3036. 97 6933. 34 1954. 89 21292. 23 8979. 28 2325. 30 6750. 59 3023. 61 22206. 26 583. 85 5176. 29 204. 78 截距 a -615. 66 -1630. 94 432. 25 -665. 07 -39. 07 3271. 90 -17210. 14 -13. 46 7. 65 -513. 46 4176. 18 -5426. 72 15. 76 4099. 82 -152. 85 相关系数 r 0. 99984 0. 99984 1. 00000 0. 99992 0. 99988 0. 99991 0. 99998 0. 99998 1. 00000 1. 00000 0. 99999 0. 99998 0. 99992 0. 99999 0. 99994 元素 C μ g /L
n j = 1 2 ∑( x ) j-x n

ICP-MS法测定水源水、出厂水、直饮水中锶、镓含量

ICP-MS法测定水源水、出厂水、直饮水中锶、镓含量
本文采用电感耦合等离子体质谱法对水源水、 出厂水、及 直 饮 水 中 的 锶 和 镓 含 量 同 时 进 行 测 定。 尚未见诸文献报道。 1 试 验 部 分 1.1 仪 器 设 备
X Series-Ⅱ 型 电 感 耦 合 等 离 子 体 质 谱 仪 (Thermo Fisher Scientific, USA ), Milli—Q Element超 纯 水 系 统 (Millipore,USA)。 1.2 仪 器 工 作 条 件
Cao Xingyu,Yuan Lujin,Fang Yueying
(Suzhou Industrial Park Qingyuan Hongkong & China Water Co.,Ltd.,Suzhou 215021,China)
Abstract:Inductively coupled plasma-mass spectrometry (ICP-MS)was applied to determine strontium and gallium in raw water,finished water and direct drinking water.The results indicated that correlation coefficients of strontium were between 0.999 4and 1.000 0,the detection limit of strontium was 0.022 μg/L.The relative standard deviations of strontium were from 0.24% to 5.10% and the recoveries of strontium were from 90.0% to 109.0%.The results indicated that correlation coefficients of gallium were between 0.999 4and 0.999 9,the detection limit of gallium was 0.038μg/L,the relative standard deviations of strontium were from 0%to 3.68% and the re- coveries of strontium were from 87.1% to 108.5%.

KED-ICP-MS测定天然饮用泉水中的18种元素含量

KED-ICP-MS测定天然饮用泉水中的18种元素含量

KED-ICP-MS测定天然饮用泉水中的18种元素含量蒋慧;雷宁生;黎林;钟格梅【期刊名称】《食品研究与开发》【年(卷),期】2016(037)016【摘要】建立碰撞反应池-电感耦合等离子体质谱(KED-ICP-MS)测定天然饮用泉水中的K、K、Na、Ca、Mg、Fe、Mn、Cu、Zn、Li、Sr、Se、As、Cd、Ni、Pb、Ba、Cr、Hg等18种元素含量的方法,采集的天然饮用泉水经过酸化处理后,采用碰撞反应池技术进行测定,通过通入氦气的碰撞反应来消除分子离子干扰,使得检测结果更加准确。

试验表明,测定18种元素的线性相关系数均>0.999,相对标准偏差为0.39%~4.97%,各元素的加标回收率均在85.4%~115.0%之间,测定各元素的标准参考物质,测定值均在标准值范围内。

【总页数】4页(P151-154)【作者】蒋慧;雷宁生;黎林;钟格梅【作者单位】广西疾病预防控制中心,广西南宁530028;广西疾病预防控制中心,广西南宁530028;广西疾病预防控制中心,广西南宁530028;广西疾病预防控制中心,广西南宁530028【正文语种】中文【相关文献】1.ICP-MS测定饮用天然矿泉水中微量元素锑 [J], 闵广全2.电感耦合等离子体质谱法测定饮用水及天然水中18种元素 [J], 邓钧;丘露3.电感耦合等离子体质谱法测定湖州地区瓶装天然饮用水中的10种金属元素及污染物元素 [J], 杨帆4.ICP-OES测定饮用天然矿泉水中23种元素含量 [J], 王利华;钟跃汉;钟启升5.ICP-MS法同时测定西藏饮用天然水中35种痕量元素 [J], 弋凯鸽;王君;杨晨;王顺芝;魏霜;李国成;曹晓钢因版权原因,仅展示原文概要,查看原文内容请购买。

ICP-AES测定长白山酸浆果实无机元素

ICP-AES测定长白山酸浆果实无机元素

ICP-AES测定长白山酸浆果实无机元素
张岚;刘莹;宋春梅
【期刊名称】《光谱实验室》
【年(卷),期】2010(027)003
【摘要】ICP-AES测定长白山酸浆果实中18种无机元素.在酸浆果实所测定的无机元素中,含量依次为K>P>Mg>Ca>Fe>Zn>Mn>Cu>Sn>Al>Ni>Mo>Cr,其中V、Co含量均<0.1mg/kg;Pb,Hg、Cd等有害重金属含量极低或未检出.该法相对标准偏差为0.14%-3.57%.
【总页数】4页(P888-891)
【作者】张岚;刘莹;宋春梅
【作者单位】吉林医药学院公共卫生系营养与食品卫生教研室,吉林省吉林市吉林大街5号,132013;长春市产品质量监督检验院,长春市,130012;吉林医药学院公共卫生系营养与食品卫生教研室,吉林省吉林市吉林大街5号,132013
【正文语种】中文
【中图分类】O657.31
【相关文献】
1.高压密封罐消解-ICP-AES法测定长白山椴树蜂花粉中多种微量元素 [J], 张京京;何萍
2.酸浆宿萼无机元素和氨基酸含量的测定 [J], 杨晓虹;田丁丁;周小平;刘立丹
3.酸浆果实与宿萼无机元素的比较分析 [J], 周小平;杨晓虹;李丽贤
4.微波消解ICP-AES法测定酸浆、毛酸浆中的微量元素 [J], 陈萍;穆文娟;王建刚
5.酸浆果实无机元素和氨基酸的含量测定 [J], 杨晓虹;陈滴
因版权原因,仅展示原文概要,查看原文内容请购买。

ICP-MS法测定长白山天然矿泉水中18种微量元素的含量

ICP-MS法测定长白山天然矿泉水中18种微量元素的含量

ICP-MS法测定长白山天然矿泉水中18种微量元素的含量贺军;周丽婷;李娜;刘特;郑东春;曲笑锋;黄鉴;叶琳【摘要】目的:检测长白山天然矿泉水中锂、铍、铝、钒、锰、钴、镍、铜、锗、砷、硒、铷、钼、银、锡、铯、锑和钡18种微量元素的含量,为评价长白山天然矿泉水质量提供参考.方法:采集吉林省长白山靖宇县五龙泉、神龙泉、银龙泉和林海泉4处天然矿泉水,水样经酸化后直接采用电感耦合等离子体-质谱(ICP-MS)法进行检测.结果:被测元素的检出限为0.005~0.573 μg·L-1,除硒元素外,其他元素相对标准偏差为0.1%~4.5%,回收率为81%~116%;4处矿泉水中的18种微量元素含量均符合GB 8537-2008饮用天然矿泉水卫生标准.结论:ICP-MS方法检出限低,具有良好的准确度和精密度,适用于多种元素快速检测;长白山靖宇县4处天然矿泉水中18种微量元素含量均符合国家饮用天然矿泉水卫生标准.【期刊名称】《吉林大学学报(医学版)》【年(卷),期】2012(038)006【总页数】4页(P1223-1226)【关键词】天然矿泉水;微量元素;电感耦合等离子体-质谱;长白山【作者】贺军;周丽婷;李娜;刘特;郑东春;曲笑锋;黄鉴;叶琳【作者单位】吉林大学公共卫生学院劳动卫生与环境卫生学教研室,吉林长春130021;吉林大学公共卫生学院劳动卫生与环境卫生学教研室,吉林长春130021;吉林大学公共卫生学院劳动卫生与环境卫生学教研室,吉林长春130021;吉林大学公共卫生学院劳动卫生与环境卫生学教研室,吉林长春130021;吉林大学公共卫生学院劳动卫生与环境卫生学教研室,吉林长春130021;吉林大学公共卫生学院劳动卫生与环境卫生学教研室,吉林长春130021;吉林大学公共卫生学院劳动卫生与环境卫生学教研室,吉林长春130021;吉林大学公共卫生学院劳动卫生与环境卫生学教研室,吉林长春130021【正文语种】中文【中图分类】R123.1随着社会经济的发展,矿泉水已经进入人们日常生活之中。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

[文章编号] 1671-587Ⅹ(2012)06-1223-04[收稿日期] 2012-06-10[基金项目] 长白山天然矿泉水水资源保护区管理局项目资助课题(20100929)[作者简介] 贺 军(1986-),男,陕西省榆林市人,在读医学硕士,主要从事环境与健康关系的研究。

[通信作者] 叶 琳(Tel:0431-85619453,E-mail:yel@jlu.edu.cn)ICP-MS法测定长白山天然矿泉水中18种微量元素的含量贺 军,周丽婷,李 娜,刘 特,郑东春,曲笑锋,黄 鉴,叶 琳(吉林大学公共卫生学院劳动卫生与环境卫生学教研室,吉林长春130021)[摘 要] 目的:检测长白山天然矿泉水中锂、铍、铝、钒、锰、钴、镍、铜、锗、砷、硒、铷、钼、银、锡、铯、锑和钡18种微量元素的含量,为评价长白山天然矿泉水质量提供参考。

方法:采集吉林省长白山靖宇县五龙泉、神龙泉、银龙泉和林海泉4处天然矿泉水,水样经酸化后直接采用电感耦合等离子体-质谱(ICP-MS)法进行检测。

结果:被测元素的检出限为0.005~0.573μg·L-1,除硒元素外,其他元素相对标准偏差为0.1%~4.5%,回收率为81%~116%;4处矿泉水中的18种微量元素含量均符合GB 8537-2008饮用天然矿泉水卫生标准。

结论:ICP-MS方法检出限低,具有良好的准确度和精密度,适用于多种元素快速检测;长白山靖宇县4处天然矿泉水中18种微量元素含量均符合国家饮用天然矿泉水卫生标准。

[关键词] 天然矿泉水;微量元素;电感耦合等离子体-质谱;长白山[中图分类号] R123.1 [文献标志码] ADetermination of 18trace elements in natural mineral waterin Changbai Mountain area by ICP-MSHE Jun,ZHOU Li-ting,LI Na,LIU Te,ZHENG Dong-chun,QU Xiao-feng,HUANG Jian,YE Lin(Department of Occupational and Environmental Health,School of Public Health,Jilin University,Changchun 130021,China)Abstract:Objective To detect the contents of 18trace elements in natural mineral water in Changbai Mountainarea,and to provide reference for evaluating the quality of natural mineral water of Changbai Mountain.Methods Wulong Sping,Shenlong Spring,Yinlong Spring and Linhai Spring were collected in Jingyu County ofJilin Province,the acidified water samples were analyzed by inductively coupled plasma mass spectrometry(ICP-MS).Results The detection limit was 0.005-0.573μg·L-1,the relative standard deviation(RSD)was0.1%-4.5%(except selenium),and the recovery rate was 81%-116%.The contents of 18trace elements in thefour natural mineral waters consistented with the national health standard of drinking natural mineral water(GB8537-2008).Conclusion ICP-MS has a low limit,good accuracy and precision,which is suit for a rapid analysisof multielement.The contents of 18trace elements in natural mineral waters of Changbai Mountain area consistentwith the national health standard of drinking natural mineral water.Key words:natural mineral water;trace elements;inductively coupled plasma mass spectrometry;ChangbaiMountain 随着社会经济的发展,矿泉水已经进入人们日常生活之中。

虽然矿泉水中的微量元素含量较低,但长期饮用对人体有着重要的生理意义。

微量元素在预防疾病方面有着重要作用[1-2],如硒可预防东北地区的克山病和大骨节病[3];铜可预防贫血、骨质疏松等[4]。

微量元素检测法通常采用火焰原子吸3221第38卷 第6期2012年11月吉 林 大 学 学 报 (医 学 版)Journal of Jilin University(Medicine Edition)Vol.38No.6 Nov.2012收光谱法和石墨炉原子吸收光谱法,但该方法操作繁琐,费时费力。

电感耦合等离子体-质谱(inductively coupled plasma mass spectrometry,ICP-MS)法具有检出限低、高效、简便、线性范围宽和多元素同时测定等优点[5],已被《饮用天然矿泉水检验方法》(GB/T 8538-2008)列为标准检验方法[6]。

本实验采用ICP-MS法检测长白山饮用天然矿泉水中18种微量元素的含量,旨在为ICP-MS方法的推广和进一步开发长白山区天然矿泉水资源提供科学依据。

1 材料与方法1.1 主要试剂及仪器 优级纯HNO3;超纯水;标准储备液:锂(Li)、铍(Be)、铝(Al)、钒(V)、锰(Mn)、钴(Co)、镍(Ni)、铜(Cu)、锗(Ge)、砷(As)、硒(Se)、铷(Rb)、钼(Mo)、银(Ag)、锡(Sn)、铯(Cs)、锑(Sb)和钡(Ba)标准储备液(c=1 000mg·L-1)(均由国家钢铁材料测试中心钢铁研究总院提供)。

电感耦合等离子体质谱仪:ELAN DRC-e型(厦门亿辰科技有限公司生产)。

1.2 仪器工作条件 仪器的优化条件为射频功率1 350W,采样深度8.5mm,载气1.24L·min-1,等离子气15L·min-1,辅助气流速1.0L·min-1,蠕动泵4.8r·min-1,采样接口镍锥0.8mm。

使用1μg·L-1的调谐液对仪器条件进行最优化调节,使仪器灵敏度最高,准确度最好。

1.3 样品的采集和保存 以吉林省长白山区靖宇县作为采样点,选择秋季丰水期进行采样。

根据靖宇县矿泉水的分布,分别选择靖宇县内的五龙泉、林海泉、神龙泉和银龙泉4处矿泉水作为矿泉水采样点,采用地理信息系统(GeographicInformation System,GIS)进行经纬度定位;在每个矿泉水出水口和涌出到地面的泉水各采集12个水样,每个水样采集1 000mL。

采集的水样保存在聚乙烯塑料瓶中,加少许HNO3使水样的pH<2,室温保存。

1.4 混合标准曲线的绘制和样品测定 用2%HNO3分别稀释标准储备液为10mg·L-1应用液。

将待测的18种微量元素配制成3种混合应用液,分别为:①V、Cu、Se、Sn、Sb和As;②Mo、Ni、Co、Mn、Ag和Cs;③Li、Rb、Al、Ge、Ba和Be。

再用2%HNO3将10mg·L-1应用液稀释成0、1.0、5.0、10.0和50.0μg·L-1混合标准使用液。

在仪器达到优化条件下进行测定,以待测物质的量为横坐标,相应的信号值为纵坐标绘制标准曲线。

在仪器达到优化条件下进行样品测定。

对空白试剂连续测定11次,3σ/r(3倍的标准偏差除以曲线的斜率)即仪器的检出限;连续测定6d,标准差与均数的比值为精密度;采用标准物质加入法进行样品回收率计算。

1.5 统计学分析 将数据录入Excel,天然矿泉水中微量元素的含量结果以x±s表示。

2 结 果2.1 微量元素检出限、精密度和回收率 仪器的检出限为0.005~0.573μg·L-1;相关系数均≥0.999。

在测定方法的线性范围内,除硒元素外,其他元素的精密度为0.1%~4.5%。

样品加标回收率为81%~116%。

见表1。

2.2 样品中微量元素含量 依据饮用天然矿泉水GB 8537-2008[6]卫生标准,长白山靖宇县4处天然饮用矿泉水中18种微量元素含量均符合矿泉水卫生标准。

见表2。

3 讨 论ICP-MS具有高效、简便、线性范围宽和检出限低等特点,适用于大批样品和多种元素的检测。

在ICP-MS分析中主要有多原子离子干扰、基体干扰和质谱干扰[7-10],本研究将18种微量元素分成3组,相对分子质量相近的元素放在同一组,水样的基体比较简单且恒定,通过扣除空白和稀释样品可对多原子离子干扰和基体干扰进行消除。

实验中使用调谐液对仪器条件进行最优化调节可有效地消除质谱干扰。

ICP-MS的椎体采用的是镍锥,在测定镍元素时,存在污染和记忆效应,在测量前应多次清洗或换取新的镍锥以保证镍含量检测结果的准确。

本研究结果显示:18种被测元素的检出限为0.005~0.573μg·L-1;除硒元素外,其他元素相对标准偏差为0.1%~4.5%,其中硒元素相对标准偏差偏大,可能与元素间的干扰有关,单测硒元素,其相对标准偏差较小;18种元素的回收率为81%~116%,表明采用ICP-MS法测定微量元素的检测结果准确可靠,可用于矿泉水中多种微量元素的同时检测。

4221吉林大学学报(医学版) 第38卷 第6期 2012年11月表1 18种微量元素检出限、回收率和精密度Tab.1 The detection limits,recovery rates and precisions of 18trace elementsElementInstrumentdetection limit[ρB/(μg·L-1)]RelatedcoefficientMean[ρB/(μg·L-1)]Spikedvalue[ρB/(μg·L-1)]Measuredvalue[ρB/(μg·L-1)]Recoveryrate(η/%)Mean[ρB/(μg·L-1)]RDS(η/%)Li 0.007 0.999 8 4.53 5 9.85 106 0.36 2.7Be 0.007 0.999 9 2.38 5 7.48 102 2.62 3.6Al 0.573 0.999 9 1.80 5 6.42 92 1.79 2.1V 0.170 0.999 9 3.47 5 9.34 118 2.66 4.5Mn 0.102 0.999 3 0.14 5 4.19 81 0.06 3.9Co 0.005 0.999 9 0.03 5 5.20 104 0.01 0.1Ni 0.039 0.999 9 0.11 5 5.47 107 0.17 1.7Cu 0.027 0.999 9 0.28 5 5.59 106 0.27 0.7Ge 0.011 0.999 9 0.00 5 5.31 106 0.01 0.6As 0.149 0.999 4 0.45 10 11.97 115 0.12 1.9Se 0.273 0.999 6 0.15 10 11.79 116 0.36 9.0Rb 0.234 0.999 9 4.75 5 9.70 99 1.43 1.7Mo 0.112 0.999 9 1.24 5 6.65 108 1.26 3.7Ag 0.038 0.999 9 0.00 5 4.10 83 0.01 1.3Sn 0.009 0.999 9 0.01 5 5.03 100 0.00 0.4Cs 0.005 0.999 9 0.01 5 5.25 105 0.01 0.1Sb 0.024 0.999 9 0.06 5 5.79 115 0.01 1.1Ba 0.009 0.999 9 0.01 5 4.90 98 0.01 0.3表2 靖宇县天然矿泉水中18种微量元素含量 Tab.2 The contents of 18trace elements of natural mineral water in Jingyu County[x±s,ρB/(μg·L-1)]Element Shenlong Spring Wulong Spring Yinlong Spring Linhai SpringLi 0.01±0.00 0.01±0.00 0.01±0.00 0.01±0.00Be-0.01±0.01--Al 3.08±1.78 3.82±1.47 0.93±0.53 2.01±1.00V 3.26±0.15 2.58±0.08 3.32±0.02 1.93±0.04Mn 0.03±0.04---Co 0.08±0.01 0.06±0.01 0.13±0.01 0.24±0.03Ni 0.66±0.03 0.57±0.03--Cu 0.50±0.02 0.30±0.04 0.24±0.01 0.60±0.03Ge----As 0.39±0.05 0.26±0.03 0.40±0.03 0.28±0.01Rb 5.32±0.05 5.85±0.40 6.46±0.11 4.13±0.11Mo 9.57±0.16 12.14±0.07 1.06±0.02 0.38±0.02Ag----Sn----Cs 1.58±0.87 0.07±0.07 0.02±0.00-Se 0.10±0.04 0.12±0.05 0.25±0.12 0.36±0.12Sb 0.06±0.03 0.07±0.01 0.04±0.00 0.05±0.01Ba 1.68±0.25 0.83±0.37 1.71±0.04 3.21±0.45 “-”:Not detected. 长白山区富含丰富的矿泉水资源,现已通过省级或国家级鉴定的矿泉水水源地有48处[11]。

相关文档