Allerair空气净化器4000至8000系列使用说明书(英文版)
欧美汽车用品-欧洲空气净化器用户手册说明书
®Your Vital Air SourceULTRA-LIGHT DUTYONBOARD AIR SYSTEMPART NO. 10000IMPORTANT:It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product.SAVE THIS MANUAL FOR FUTURE REFERENCE98C AIR COMPRESSOR INSTALLATIONYour Ultra Light Duty Onboard Air System comes complete with a 98C, 10% duty cycle compressor. Please follow the installation instructions that follow to enjoy the best use of your onboard air system. CAUTION - To reduce risk of electrical shock or electrocution:- Do not disassemble the compressor. Do not attempt repairs or modifications.R efer to qualified service agencies for all service and repairs.- Do not use this product in an area where it can fall or be pulled into water or liquids.- Do not reach for this product if it has fallen into liquid.- Use this compressor with 12-volt DC systems only.- This product should never be left unattended during use.Guidelines for Selecting Mounting Location:The selection of proper mounting location for your air compressor will help ensure a longand trouble free compressor service life. Please pay close attention to the following:- Select a FLAT, UPRIGHT & SECURE LOCATION where the compressor can be mounted.- To maximize air compressor performance, install compressor as CLOSE TO THE BATTERYas possible so that length of positive lead wire is as short as possible.- This compressor is moisture & dust resistant, but NOT WATERPROOF or DUSTPROOF.Do not mount compressor in locations where the unit is likely to come in contact with water or excessive dirt. - If it is necessary to mount the air compressor further from the battery, such as inside your vehicle or inthe bed of your pickup, VIAIR recommends using wire larger than 12 AWG as a positive lead forremote installation.- Do not mount compressor near areas where flammable liquids are stored.- Use thread sealant for proper fitting installation. Thread tape is not recommended.Properly sealed, recommended torque for 1/4" and 3/8" is 12~15 ft. lbs.Recommended torque for 1/8" is 10~11 ft. lbs.98C Compressor Wiring: (See Figure 3 on back of manual)1. Disconnect ground cable from vehicle’s battery.2. Temporarily position the air compressor in the location where it will be mounted.3. Route ground wire to the negative post of the battery or to an appropriate grounding point andcut ground wire to length as needed.4. Mount the 98C air compressor with the two 13/64" (5 mm) bolts, nuts, washers, and locking washersprovided. Use of thread locker is recommended.5. This air compressor comes with a heavy duty heat resistant stainless steel braided leader hose. This leaderhose is designed to prolong the life of your air line. Do not remove this leader hose from air compressor. 6. IMPORTANT: Please note; the leader hose that came with your compressor has a built-in inline check valvepre-installed. Do not remove inline check valve from leader hose.7. To mount hose bracket, drill holes with 3/16" drill bit and push self–anchoring hose bracket pin into hole.Route leader hose through hose bracket and secure hose by pressing bracket clamp into locked position.8. To remove hose from the hose bracket, simply press down on the hose clamp release tab to releasebracket clamp.9. Connect compressor’s positive lead wire to one of the leads of your pressure switch.10. Make sure that your compressor setup is properly fused. The 98C pulls approximately 13 amps of power.11. Always locate fuse as close as possible to power source.12. Before connecting to power source, check to make sure that all connections are made properly.13. Connect and test compressor system by running the compressor for a short time to build up pressurein your air tank.14. Once air pressure reaches preset cut out pressure of your pressure switch, the compressor will shut off.Inspect all air line connections for leaks with soap and water solution. If a leak is detected, the air line may not be cut squarely or pushed all the way in. Tighten connections if needed.COMPRESSOR APPLICATION GUIDETo ensure that you get the highest level of satisfaction from your compressor performance, refer to information below:VIAIR COMPRESSOR REFERENCE CHARTCOMPRESSOR SERIES MAX. WORKING DUTY CYCLEPRESSURE (100 PSI @ 72°F)090 SERIES 120 PSI 9%092 SERIES 120 PSI 9%095 SERIES 120 PSI 9%097 SERIES 130 PSI 10%098 SERIES 130 PSI 10%100 SERIES 130 PSI 15%250 IG SERIES 150 PSI 100%275 SERIES 150 PSI 25%280 SERIES 150 PSI 30%325 SERIES 150 PSI 33%330 IG SERIES 150 PSI 100%350 SERIES 150 PSI 100%380 SERIES 200 PSI 100%55% @200 PSI400 SERIES 150 PSI 33%420 SERIES 150 PSI 33%425 SERIES 175 PSI 33% @175 PSI50%444 SERIES 200 PSI 100%50% @200 PSI450 SERIES 150 PSI 100%450 IG SERIES 150 PSI 100%460 SERIES 150 PSI 100%480 SERIES 200 PSI 100%50% @200 PSI485 SERIES 200 PSI 100%100% @200 PSIABOUT COMPRESSOR DUTY CYCLE:Duty cycle refers to the amount of time a compressor can beoperated in a given time period at 100 PSI, and a standard ambient temperature of 72° F. It is commonly expressed in percentage format: Compressor on time ÷ (on time + off time) = Duty Cycle %.ONE-HOUR DUTY CYCLE MINUTES ON /(100 PSI @ 72°F) MINUTESOFF9% 5 Min. On / 55 Min. Off10% 6 Min. On / 54 Min. Off15% 9 Min. On / 51 Min. Off20% 12 Min. On / 48 Min. Off25% 15 Min. On / 45 Min. Off30% 18 Min. On / 42 Min. Off33% 20 Min. On / 40 Min. Off50% 30 Min. On / 30 Min. Off100% 1 Hour Run TimeNOTE: All compressors, regardless of rated duty cycle, require sufficient rest time in between cycles to allow for partial or complete heat dissipation. Heat dissipation rates may vary depending on ambient temperatures and operating conditions.ABOUT RATED WORKING PRESSURE:To ensure trouble free service life of your compressor, always operate compressor within rated working pressure of the compressor. Never use a pressure switch with a higher cut-off pressure than compressor’s rated working pressure.TROUBLESHOOTING GUIDE:Tank pressure drops when compressor (s) shut off 1. Loose drain cock2. Check valve leaking3. Loose connections1. Tighten drain cock2. Replace check valveor compressor(s)3. Check all connections withsoap and water solutionand tightenCompressor runs continuously and air flow lower than normal 1. Excessive air usage2. Loose connections3. Worn piston ring orinlet valve4. Clogged air filter element1. Decrease air usage2. Check all connections withsoap and water solutionand tighten3. Repair or replace compressor4. Replace air filter elementCompressor runs continuously causing safety valve (if equipped) to open 1. Bad pressure switch2. Defective safety valve1. Replace pressure switch2. Replace safety valveExcessive moisture in discharge 1. Excessive water in air tank2. High humidity 1. Drain tank, tilt tank to drain Drain tank more frequently 2. Move compressor to area with less humidity, or use air line filterCompressor will not run 1. No power, or power switchin OFF position2. Blown fuse3. Motor overheats4. Faulty pressure switch 1. Make sure compressorswitch is ON2. Disconnect compressorsfrom power source, replace fuse (Refer to Specifications section for correct fuseamperage)3. Let compressors cool off for about 30 Minutes to allow thermal overload switch reset4. Replace pressure switchThermaloverload protector cuts out repeatedly 1. Lack of proper ventilation orambient temperature too high2. Compressor valves failed1. Move compressor to wellventilated area, or area withlower ambient temperature2. Repair or replace compressorExcessive knocking or rattling1. Loose mounting bolts2. Worn bearing on eccentric ormotor shaft3. Cylinder or piston ring is worn1. Tighten mounting bolts2. Repair or replacecompressor3. Repair or replacecompressorCAUTION: NEVER DISASSEMBLE COMPRESSOR WHILECOMPRESSOR IS PRESSURIZED.POSSIBLE CAUSE(S)PROBLEM CORRECTIVE ACTION。
空气净化器用户使用手册
空气净化器用户使用手册Scqair1苍穹空气净化器用户使用手册企业简介........................................................... 2 整机及配件......................................................... 3 产品部件介绍...................................................... 4 快速使用指南...................................................... 5 注意事项............................................................ 6-7 操作说明............................................................ 8-9 净化功能........................................................... 10 技术创新........................................................... 11 工作原理........................................................... 12 技术参数........................................................... 13 保养维护........................................................... 14 故障排除........................................................... 15 使用前操作事项.................................................. 16 售后服务........................................................... 17 产品合格证........................................................ 17 售后服务卡.. (18)感谢您使用苍穹空气净化器,使用前请仔细阅读使用手册并妥善保管。
ELECTROLUX PURE A9-40 PURE A9-60 空气净化器 用户手册说明书
用户指导手册PA91-604GYPA91-404GYPA91-404DG设备:A.控制面板B.出风口C.空气质量灯D.空气质量传感器E.织物手柄F.多层过滤器G.进气门H.进气口I.产品手柄控制面板:J.装载指示灯K.手动模式指示灯L.WiFi指示灯M.童锁指示灯N.过滤器更换指示灯O.离子发生器指示灯P.编程指示灯Q.风扇速度滑动条R.智能模式指示灯S.模式键T.开/关键PURE A9-40/PURE A9-60 空气净化器说明功能可能会随新应用程序的发布而增加或更新。
2CN4 5安全说明本用户手册提供了适用于您的型号的具体操作说明。
请仅按照本用户手册中的说明使用本机。
这些说明并不意味着涵盖可能发生的每种可能的条件和情况。
安装、操作和维护任何设备时,必须遵守常识和注意事项。
警告!避免火灾或触电。
请勿使用延长线或适配器插头。
请勿从电源线上取下任何插脚。
本机可在50 Hz 或60 Hz 电源下使用,无需任何更改。
在任何情况下,切勿切断、拆除或绕过接地插脚(参见第5页图24)。
英标版,另见第5页图25。
请勿在本机或任何其他设备附近存放或使用汽油或其他易燃蒸气和液体。
请阅读有关可燃性和其他警告的产品标签。
请勿让水或任何其他液体或易燃洗涤剂进入本机,以免触电和/或引发火灾。
拆卸过滤器时请勿触摸风扇叶片。
儿童和弱势群体的安全警告!窒息、受伤或永久伤残风险。
8岁及以上儿童以及体力、感官或智力受损、或缺乏相关经验和知识的人员使用本设备时,应处于监护之下,或在安全使用本设备方面给予相应指导,了解其中所存在的危险。
儿童不得将本品当作玩具使用。
除非处于监护之下,否则不得由儿童进行清洁和用户维护。
除非处于持续监护之下,否则三岁以下儿童不得靠近本设备。
保证儿童远离所有包装。
电气信息警告!避免火灾或触电。
如果您不确定插座是否已通过延时保险丝或断路器充分接地或进行保护,则请由合格的电工根据国家电气规范和适用的当地法规和条例安装合适的插座。
Beurer空气净化器英文版说明书
Beurer GmbH • Söfl inger Str. 218 • 89077 Ulm, GermanyTel.: +49 (0)731 / 39 89-144 • Fax: +49 (0)731 / 39 89-255www.beurer.de •Mail:************D Luftwäscher GebrauchsanleitungG Air washerInstruction for Use LW 110Das Gerät ist doppelt schutzisoliert und entspricht der Schutzklasse 2.1. Zum KennenlernenDer Mensch verbringt den größten Teil seiner Zeit in geschlossenen Räumen. Oft ist diese Luft mit Staubpar-tikeln, Pollen, Tierhaaren und Gerüchen belastet und – besonders in der Winterzeit – zu trocken. Zu trockene23Allgemein wird eine relative Luftfeuchtigkeit von 40 bis 60% empfohlen. Doch im Winter wird dieser Wert häufig unterschritten, wenn beim Lüften kalte Luft in Wohnräume strömt und dann aufgewärmt wird. Denn bei steigender Lufttemperatur kann die Luft zunehmend mehr Feuchtigkeit aufnehmen. Die Luft deckt den Feuchtigkeitsbedarf aus anderen Quellen, wie z.B. Schleimhäute, Haut, Einrichtungsgegenstände, etc. Dies kann eine Reihe negativer Auswirkungen haben:– Schleimhäute trocknen aus, Lippen werden spröde und trocknen aus, Augen brennen,– Infektionen und Erkrankungen der Atemwege werden begünstigt,– Abgespanntheit, Müdigkeit und Konzentrationsschwäche,– Haustiere und Zimmerpflanzen werden belastet,– Förderung der Staubentwicklung und elektrostatischer Aufladung von Textilien aus Kunstfasern, Teppichen und Kunststoffböden,– Beschädigung von Einrichtungsgegenständen aus Holz und besonders Parkettböden,– Verstimmung von Musikinstrumenten.Der Luftwäscher bietet der Luft nun die Möglichkeit, den Feuchtigkeitsbedarf an der grossen Oberfläche der feuchten Befeuchterscheiben zu decken. Die Luftbefeuchtung erfolgt nach dem Prinzip der selbstregulie-renden Kaltverdunstung. Es sind keine zusätzlichen Steuergeräte notwendig.Zur Keimfreihaltung und Verdunstungsförderung benötigt der Luftwäscher einen Wasserzusatz. Eine regel-mäßige Reinigung ist unerlässlich. Verwenden Sie dazu die mitgelieferte Reinigungslösung.2. Bestimmungsgemäßer GebrauchDieser Luftwäscher ist bestimmt zur Reinigung und Befeuchtung der Luft in Innenräumen.WARNUNG– Dieses Gerät ist nicht dafür bestimmt, durch Personen (einschließlich Kinder) mit eingeschränkten physischen, sensorischen oder geistigen Fähigkeiten oder mangels Erfahrung und/oder mangels Wissen benutzt zu werden, es sei denn, sie werden durch eine für ihre Sicherheit zuständige Person beaufsichtigt oder erhielten von ihr Anweisungen, wie das Gerät zu benutzen ist.– Kinder sollten beaufsichtigt werden, damit sie nicht mit dem Gerät spielen.– Wenn Sie an einer schweren Krankheit der Atemwege oder Lunge leiden, befragen Sie vor der Benutzung des Luftwäschers Ihren Arzt.– Das Gerät ist nur für den in dieser Gebrauchsanleitung beschriebenen Zweck vorgesehen. Der Hersteller kann nicht für Schäden haftbar gemacht werden, die durch unsachgemäßen oder leicht-sinnigen Gebrauch entstehen.3. SicherheitshinweiseLesen Sie diese Gebrauchsanleitung sorgfältig! Ein Nichtbeachten der nachfolgenden Hinweise kann Perso-nen- oder Sachschäden verursachen. Bewahren Sie die Gebrauchsanleitung auf und machen Sie diese auch anderen Anwendern zugänglich. Übergeben Sie diese Anleitung bei Weitergabe des Geräts.WARNUNGHalten Sie Kinder von Verpackungsmaterial fern. Es besteht Erstickungsgefahr.StromschlagWARNUNGWie jedes elektrische Gerät ist auch dieser Luftwäscher vorsichtig und umsichtig zu gebrauchen, um Gefahren durch elektrische Schläge zu vermeiden.• Betreiben Sie das Gerät deshalb– n ur mit der auf dem Gerät notierten Netzspannung (das Typenschild befindet sich innen an derVentilatoreinheit),– nie, wenn das Gerät oder Zubehör sichtbare Schäden aufweist,– nicht während eines Gewitters.• Schalten Sie das Gerät im Falle von Defekten oder Betriebsstörungen sofort aus und trennen Siedas Gerät vom Stromanschluss. Ziehen Sie nicht am Stromkabel oder am Gerät um den Stecker4678567Trennen Sie dazu die Ventilatoreinheit von der Oberschale, indem811. Garantie und ServiceSie erhalten 3 Jahre Garantie ab Kaufdatum auf Material- und Fabrikationsfehler des Produktes. Die Garantie gilt nicht:•im Falle von Schäden, die auf unsachgemäßer Bedienung beruhen,•für Verschleißteile,•für Mängel, die dem Kunden bereits bei Kauf bekannt waren,•bei Eigenverschulden des Kunden.Die gesetzlichen Gewährleistungen des Kunden bleiben durch die Garantie unberührt. Für Geltendmachung eines Garantiefalles innerhalb der Garantiezeit ist durch den Kunden der Nachweis des Kaufes zu führen. Die Garantie ist innerhalb eines Zeitraumes von 3 Jahren ab Kaufdatum gegenüber der Beurer GmbH, Söflinger Straße 218, 89077 Ulm, Germany geltend zu machen. Der Kunde hat im Garantiefall das Recht zur Reparatur der Ware bei unserem eigenen oder bei von uns autorisierten Werkstätten. Weitergehende Rechte werden dem Kunden (aufgrund der Garantie) nicht eingeräumt.91. Getting to know your deviceHumans spend a large proportion of their time indoors. The air indoors is often polluted with dust particles, pollen, animal hair and odours and is too dry, particularly in winter. Ambient air that is too dry may have a1011126781314When putting the fan unit down, ensure that it does not15753.899 – 0710 I r r t u m u n d Än d e r u n g e n v o r b e h a l t e n。
朴素空气净化器说明书
Manual v1.0OUTDOOR MISTINGFANFMF2K5BK00 Owner’s Manual2R EAD AND SAVE THESEINSTRUCTIONS . Register Your Product Online (3)Important Safety Instructions/Warnings ................................................ 4 Parts Lists .. (6)Assembly Instructions (7)Operating Instructions (9)Cleaning and Maintenance (10)Troubleshooting (12)Limited Manufacturer’s Warranty (13)MODEL NOFMF2K5BK00 RATED VOLTAGE120V RATED FREQUENCY60 Hz RATED POWER55W CURRENT0.45A FAN SPEEDS3 SPRAY NOZZLES3 AIRFLOW2400 CFM COVERAGE 500 square feetFrigidaire is a registered trademark of Electrolux Home Products, Inc. All rights reserved. Manufactured under license by: NewAir, LLC 6600 Katella Ave, Cypress, CA 90630 Comments/questions: ******************|855-963-92473Register Your Frigidaire Product Online Today!Take advantage of all the benefits product registration has to offer:Service and SupportDiagnose troubleshooting and service issues faster and more accuratelyRecall NotificationsStay up-to-date on safety notices, system updates, and recall notificationsSpecial PromotionsOpt-in for NewAir promotions and offersRegistering your product information online is safe &secure and takes less than 2 minutes to complete:Alternatively, we recommend you attach a copy of your sales receipt below and record the following information, which can be found on the manufacturer’s nameplate on the back of the unit. You will need this information if it becomes necessary to contact the manufacturer for service inquiries.Date of Purchase: ___________________________________________ Serial Number: _____________________________________________ Model Number: ____________________________________________4CAUTION: Read rules for safe operation and instructions carefully.When using any electrical appliance, basic safety precautions must be followed in order to reduce the risk of fire, electrical shock and/or injury to persons or property. Be sure to read all instructions before using this appliance and observe the following safety tips:1.To reduce the risk of fire or electrical shock, do not use this fan withany solid state speed control device (e.g. a dimmer switch).2.This product must be grounded properly when plugged in. If theunit should malfunction or break down, a grounded power cord will keep you safe. This product is equipped with a grounded powercord. Plug into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.3.This fan is provided with a ground fault circuit interrupter (GFCI)built into the power supply cord. This device provides additionalprotection from the risk of electric shock. Should replacement ofthe plug or cord become necessary, use only identical replacement parts that include GFCI protection.4.Do not leave the fan running unattended.5.Do not use the fan where it may get wet from rain, sprinklers, etc.Water could leak inside of the unit and damage the internalcomponents.6.Do not insert anything through the fan cover, especially while thefan is running.7.Before using the unit, check if the voltage indicated correspondswith the intended outlet (120V).8.Connect power after the fan is fully assembled.9.Unplug from the outlet when not in use, when moving the fan fromone location to another, before putting on or taking off parts, and before cleaning.10.Be sure the fan is on a stable surface when operating to avoid itfalling over, and ensure the power cord is not a trip hazard.11.Do not use any appliance with a damaged cord or plug. Discard fanor return to an authorized service facility for examination and/orrepair if the power cord or plug are damaged.12.Children should be supervised to ensure they do not play with oraround the appliance.513.This product employs overload protection (fuse). A blown fuseindicates an overload or short-circuit. If the fuse blows, unplugthe product from the outlet. Replace the fuse as per the userservicing instructions and check the product. If the replacement fuse blows, a short-circuit may be present and the product should be discarded or customer service should be contactedimmediately.14.Press the TEST button (then RESET button) on the power cableGFCI box once every month to ensure proper operation.15.Risk of Fire: Do not replace or modify any part of the power cord,GFCI or wall plug. Do not remove the fuse unless you arereplacing it. If any of these parts are damaged, contact customer service immediately.16.Place the fan on a level surface. Plug the grounding typeattachment plug into a standard 120V AC 3-Pring wall outlet.SAVE THESE INSTRUCTIONS6A.Front grilleB.Blade capC.Fan bladeD.Plastic nutE.Rear grilleF.Motor shaftG.Clutch knobH. Motor housing I.Control panelJ.Thumb screwK.Power cordL.Waterproof cover M.Misting line clipN.Internal poleO.Height adjustment knob P.External poleQ.Misting line R.Filter washer S.Water valve T.Fan base U.Screw for base7Before beginning assembly of this product, make sure all parts are included in the box (see chart on previous page). If any part is missing or damaged, do not attempt to assemble the product. Contact customer service for replacement parts. You should only need a philips head screwdriver for assembly, and about 15 minutes of time.81.Unscrew the screw (U) from the external pole (P) andattach the external pole (P) to the base (T) bytightening the screw (U).2.Remove the height adjustment knob (O) by unscrewing itcounterclockwise.e your finger to pull out the internal pole (N), slide heightadjustment knob (O) over internal pole (N). Fasten it to external pole (P) by turning the knob while holding the pole. Make sure the knob (O) is tightly fastened before final assembly.1.Remove the blade cap (B) by turning clockwise. Remove the plasticnut (D) by turning counter clockwise.2.Position the rear grille (E) over the motor shaft (F), making certain that the handle is at the top, and that the one notch on the back of of rear grille (E) fits over the three prong attachment on the motor housing (H on parts list).3.Secure rear grille (E) by turning the plastic nut (D) clockwiseand tightening firmly.4.Slide the fan blade (C), with the hollow interior of the blade facingtoward rear grille (E), onto motor shaft (F).5.Secure fan blade (C) onto motor shaft (F) by turningthe blade cap (B) counterclockwise until firmly inplace.6.Loosen the bolt on the bottom of front grille (A) and mount the front grille (A) with the logo right side up to rear grille (E) by snapping both together firmly. Ensure all snaps around frontgrille (A) are secured onto rear grille (E).7.Tighten the bolt on the bottom of front grille (A).1.Loosen the thumb screw (J) by turning it counterclockwise.2.Always keep the waterproof cover (L) match with the height adjustable knob (O) when adjusting the internal pole (N).3.Insert internal pole (N) into the neck joint and tighten byturning thumb screw (J) clockwise. Make sure it is tightenough to support the fan head.4.Attach the Misting Line holder (M) onto the Internal pole (N).5.Secure the Misting Line (Q) to the clip under front grille (A) and themisting line clip (M).91. Plug in the unit, press the reset button on theGFCI, and select a fan speed on the controlpanel. The fan will start running as soon as youselect a fan speed.2. To start/stop fan oscillation, push down/pull upthe clutch knob (G).3. To adjust the airflow upward or downward,simply tilt the fan head by hand and move to thedesired angle.4. The height of the fan can be adjusted byloosening the height adjustment knob (O) andcarefully raising or lowering the fan and retightening the knob.1. Connect a standard ¾” garden hose to the misting hosevalve (S). Water pressure should not exceed 550 kPa (5.6 kfg/cm2). Only use a hose in good condition.2. With the garden hose turned on at the spigot, turn the leveron the misting hose valve to the right to turn on water to the fan.3. Turn the lever back (to the left) to temporarily disable themisting feature. To disable the misting feature for a longer period of time, close the water valve lever and turn the spigot off as well.3 2 10101.Disconnect from the electrical socket during cleaning or initialassembly.2.To ensure adequate air circulation to the motor, keep the ventsat the rear of the motor housing clear of dust, dirt, etc. Unplug the fan before using a vacuum cleaner or compressed air toclean the grilles. It should not be necessary to disassemble the fan to clean it.3.Wipe the exterior housing of the fan with a soft cloth soaked ina mild detergent. Do not use any abrasive detergents orsolvents to avoid damaging the surface. Do not use gasoline,thinner, or bending to clean the fan.4.Do not allow water or any other liquid into the motor housing orinterior parts.5.When dismantling the fan (we recommend following theassembly instructions in reverse), be sure to clean each of the components before storage. Allow all parts to dry completely before storing.6.To test the GFCI feature, press the "TEST" button. The fanshould immediately shut off as if the GFCI has been tripped.Press the "RESET" button and the fan should be able to beturned on again, and the light on the GFCI box should light up orange. If it does, then the unit (as well as the GFCI feature) are functioning normally.7.If the fuse in the power cord plug needs to be replaced, followthese instructions:a)Pull the power plug from the outlet, being careful not topull from the cord.b) Slide open the fuse access cover.c) Remove the fuse slowly and carefully by inserting a smalltool into the fuse slot and prying it out. When one side of the fuse has been lifted out, you will be able to remove it entirely.d) Only replace the fuse with 5 Amp / 125 Volt fuses. Using anincompatible fuse may cause a fire.e) Close the fuse cover.f) Caution: Do not attempt to replace the plug or the powercord itself. Only replace a broken fuse with a compatible fuse.If any part of the plug or cord are damaged, contact customer service for assistance.111.Grasp plug and remove from the receptacle or other outletdevice. Do not unplug by pulling on cord.2.Open fuse cover. Slide open fuse access cover on top ofattachment plug towards blades.3.Remove fuse carefully. Insert the tip of your tool into fuseslot (close with the terminal), then prize the fuse graduallyand slowly, but not overexert. If you feel tight, you can try itat several times and prize the fuse little by little. When oneside of the fuse has been prized, then you can get the fuseout entirely.4.Risk of fire. Replace fuse only with 5 Amp, 125 Volt fuse.5.Close fuse cover. Slide closed the fuse access cover on topof attachment plug.6.Risk of fire. Do not replace attachment plug. Contains asafety device (fuse) that should not be removed. Discardproduct if the attachment plug is damaged.If the misting nozzles become clogged, unscrew them from the fan grille and soak in vinegar or a lime scale remover until they are clear of buildup. Use a non-metallic brush to scrub them if necessary. If the nozzles remain obstructed, contact customer service for replacement.Warning: never try to clear the nozzles with pins or other sharp objects as this can cause damage to the nozzles, affecting their efficiency.If the misting hose valve becomes clogged, unscrew the head of the valve and flush it with running water to clear debris. Make sure the screen inside the misting hose is clean as well.12The fan has no power. The unit may beplugged in using adifferent voltage.Check if using the wrongvoltage.The circuit breakermay be tripped orthere is a blown fuse.Reset the circuit breaker orcheck for a broken fuse.The fan is not rotating. There is anobstruction.Check for obstructions inthe fan. If you findsomething, turn the fanoff. Unplug the fan andcarefully remove theobstruction. Plug the fan inand turn it on again byreferring to the operatinginstructions.No mist is produced. There is no watercoming from the hose.Make sure the garden hoseis correctly connected tothe spigot and the mistinghose valve, that the spigotis turned on, and that thevalve is open.Nozzles are leaking or dripping. The nozzles areclogged.Clean the clogged nozzleson the front of the fan asdescribed under “Cleaning& Maintenance.”13This appliance is covered by a limited manufacturer’s warranty.For one year from the original date of purchase, themanufacturer will repair or replace any parts of this appliancethat prove to be defective in materials and workmanship,provided the appliance has been used under normal operating conditions as intended by the manufacturer.Warranty Terms: During the first year, any components of this appliance found tobe defective due to materials or workmanship will be repaired or replaced, at the manufacturer’s discretion, at no charge to theoriginal purchaser. The purchaser will be responsible for anyremoval or transportation costs.Warranty Exclusions:The warranty will not apply if damage is caused by any of the following:•Power failure•Damage in transit or when moving the appliance•Improper power supply such as low voltage, defective household wiring or inadequate fuses•Accident, alteration, misuse or abuse of the appliance such as using non-approved accessories, inadequate air circulationin the room or abnormal operating conditions (extremetemperatures)•Use in commercial or industrial applications•Fire, water damage, theft, war, riot, hostility or acts of God such as hurricanes, floods, etc.•Use of force or damage caused by external influences•Removal of stickers and/or screws•Partially or completely dismantled appliancesObtaining Service: When making a warranty claim, please have the original bill ofpurchase with purchase date available. The purchaser will be responsible for any removal or transportation costs.Replacement parts and/or units will be new, remanufactured or refurbished and are subject to the manufacturer’s discretion.For technical support and warranty service, please email******************Frigidaire is a registered trademark of Electrolux Home Products, Inc.All rights reserved.Manufactured under license by:NewAir, LLC6600 Katella Ave, Cypress, CA 90630。
费尔斯菲尔斯800系列空气净化器说明书
Philips 800 SeriesAir PurifierPurifies rooms up to 49 m²190 m³/h clean air rate (CADR)HEPA filterAC0820/30Purifies the air in less than 16 mins (1)99% virus, allergen & pollutant removal (2,3,6)With just one push of a button, the air purifier filters the invisible viruses, allergens orpollutants in your home, to keep it clean and safe. It purifies quickly and effectively, thanksto its clean air delivery rate (CADR) of 190 m³/h.Superior performance•High Performance suitable for rooms of up to 49 m²•Filters 99.5% particles as small as 0.003 microns•Removes up to 99.9% of viruses and aerosols from the air•Smart sensors for intelligent purification•Thoroughly tested for quality you can trustSeamless operation•Sleep mode with ultra-quiet operation•Low energy consumptionEffortless control•Air quality display•Smart filter indicator•Auto mode and 2x manual speed levelsHighlightsHigh PerformancePowerful airflow circulation effectively covers rooms up to 49 m² and distributes clean air in every corner of the room. This boostsperformance to 190 m³/hr CADR (Clean Air Delivery Rate). It cleans 20 m² in less than 16 min. (1)99.5% particle removal2-layer filtration with NanoProtect HEPA and pre-filter captures 99.5% of ultra-fine particles as small as 0.003 microns (3), so you are safe from PM2.5, bacteria, pollen, dust, pet dander and other pollutants. Certified by the European Centre for Allergy Research Foundation.Up to 99.9% virus removalCaptures aerosols including those which may contain respiratory viruses. Testedindependently by airmid health-group to remove up to 99.9% of viruses and aerosolsfrom the air (2). Also tested for coronavirus (4).Intelligent sensorsScans the air 1000x a second to detect ultra fine-particles. Reports the air quality in real time, and intelligently chooses the right speed for your home (in auto mode).Quality you can trustPhilips purifiers go through 170 mandatory and strict inspection tests before releasing from factory. They are subjected to rigorous life and durability tests, for continuous operation 24/7.Ultra-quiet operationIn Sleep mode, display lights are dimmed, and the purifier operates in near silence for clean air while you sleep.Low energy consumptionThanks to its energy efficient design, the air purifier runs at max. 20 W power. This is equivalent to a standard light bulb.Air quality displaySee the real-time air quality in your home at a glance. The display shows the level of allergens and PM2.5 with an intuitive color ringAuto mode and 2x speed levelsRun your product in intelligent automatic mode or choose from 2x speed levels: Sleep, Turbo – to be fully in control of the airflow and sound level.Issue date 2022-06-03 Version: 10.10.1EAN: 08 72038 90133 48© 2022 Koninklijke Philips N.V.All Rights reserved.Specifications are subject to change without notice. Trademarks are the property of Koninklijke Philips N.V. or their respective owners.SpecificationsWeight and dimensions •Weight:2.4 kg•Dimensions (L*W*H): 250*250*367•Color(s): White, Black Performance•CADR (Particle, GB/T): 190 m³/h •Room size (NRCC): Up to 49 m²•Filtration: HEPA, Prefilter•Air quality sensor(s): PM2.5 particle •Particle filtration: 99.5% at 0.003 microns •Allergens filtration: 99.99%•Virus & aerosol filtration: 99.9% Usability•Min. sound level (Sleep mode): 19 dB •Automatic mode •Cord length: 1.6 m•Sleep mode•Manual speed settings: 2 (Sleep, Turbo)•Air quality feedback: Color ring•Auto-ambient light: No•Max. sound level (Turbo mode): 49 dB (7)Energy efficiency•Max. power consumption: 20 W•Stand-by power consumption: <=0.5 W•Voltage: 220-240 VMaintenance•Replacement filter HEPA: HEPA filter FY0194 - 12months•Service: 2-year worldwide guarantee*(1)From the air that passes through the filter, it is a theoretical timefor one-time cleaning calculated by dividing its CADR 190 ?/h by theroom size of 49 ? (assuming the room is 20 ? in floor area and 2.4 min height).*(2) Microbial Reduction Rate Test conducted at Airmid Health groupLtd. tested in a 28.5? test chamber contaminated with airborneinfluenza A(H1N1). An air purifier by itself does not protect againstCovid-19, but can be part of plan to protect yourself and your family(US Environmental Protection Agency)*(3)From the air that passes through the filter, tested with NaClaerosol by iUTA according to DIN71460-1.*(4)Microbial Reduction Rate Test at external lab, in a test chambercontaminated with avian coronavirus (IBV) aerosols, with PhilipsHEPA NanoProtect filter.*(5)The recommended service life for the device is based on atheoretical calculation of the average annual regional values ??ofharmful air particles outdoors and daily use of the air purifier for 16hours in automatic mode.*(6)Tested on the filter media for 1 pass efficiency at 5.33cm/s airflow, by a third party lab./From the air that passes through the filter,tested to JISB 9908-2011*(7)The calculated average sound pressure at 1.5 meter from thedevice, based on measurements according to IEC 60704. Soundpressure level depends on the room construction, decoration andpositioning of device and listener.。
西安洁空空气净化器用户手册说明书
AC5665用户手册 3EN User manual3ZH-S 简体中文目录1 重要事项 4安全 42 您的空气净化器 6产品概述 6控件概览 73 使用入门 8安装过滤网 8Wi-Fi 指示灯 9Wi-Fi 连接 94 使用产品 10了解空气质量指示灯 10打开和关闭 11更改自动模式设置 12更改风速 13使用灯光开/关功能 14设置童锁 145 清洁 15清洁计划 15清洁产品机身 15清洁出风口盖 15清洁空气质量传感器 16清洁预过滤网 166 更换空气净化滤网 18了解健康空气智能锁 18更换过滤器 18过滤网强行重置 19更换过滤网类型 207 存放 218 故障排除 229 保修与服务 24订购部件或附件 2410 注意事项 24电磁场 (EMF) 24回收 24注意事项 241 重要事项安全使用本产品之前,请仔细阅读本用户手册,并妥善保管以备日后参考。
危险• 切勿让水或任何其它液体或易燃性清洁剂进入产品,以免发生触电和/或火灾。
• 切勿用水或任何其它液体或(易燃性)清洁剂来清洁产品,以免发生触电和/或火灾。
• 切勿在产品周围喷洒杀虫剂或香水等任何可燃材料。
警告• 在将产品连接电源之前,请先检查产品所标电压与当地的供电电压是否相符。
• 如果电源软线损坏,为避免危险,必须由制造厂或其维修部或类似的专职人员来更换。
• 如果插头、电源线或产品本身受损,请勿再使用本产品。
• 本产品适合由 8 岁或以上年龄的儿童以及肢体不健全、感觉或精神上有障碍或缺乏相关经验和知识的人士使用,但前提是有人对他们使用本产品进行监督或指导,以确保他们安全使用,并且让他们明白相关的危害。
不得让儿童玩耍本产品。
请勿让儿童在无人监督的情况下清洁和保养产品。
• 请勿堵塞进风和出风口,例如不要将物体放置在出风口上或进风口前方。
• 确保异物未通过出风口进入产品内部。
小心• 本产品不能替代正常通风、日常吸尘或者在烹饪时使用的抽油烟机。
洁净空气净化器说明书
44106106803June 2007Specifications subject to change without notice.INSTALLATION INSTRUCTIONSFor Propane to Natural Gas Conversion Kit Model No:NAHA001NG or Part No.(1172960)CONVERT ”Series”BTUHN8MPN/L ”B”50,75,100,125*8MPN/L ”B”50,75,100,125*8MPN ”B”150*8DNL ”B”50,75,100,125H8UH5,MUF,HL ”C”50,75,100,125,140N9MPD ”A”50,75,100,125*9MPD “C”50,75,100,125NOT FOR USE ONBTUHN9MP1”C”40,60,80N9MP2”C”80N9MPD ”A”40,60,80*9MPD ”C”80*9UHX ”A”60,80,100use NAHA004NG (1174907)*Denotes Brand (T,H orC)This conversion kit shall be installed by a qualified service agency.Please read these instructions completely before attempting installation.Consult gas supplier and tables in National Fuel Gas Code NFPA 54/ANSI Z223.1,2006or latest edition.In Canada,the National Standard CAN/CGA B149.1and B149.2--05.Parts List DescriptionPart#Qty.BurnerOrifice #4210113516Honeywell Conv.Kit #39622211729521Label,Field Conversion 10096781Label,Nat Conversion 11729551Label,Derate 25052351Instructions 441061068031Orifices for 40k,60k,80k,*9UHX and alternate input unit conversion (see unit Installation Instructions to determine if model may use alternate input)(Not included in kit)(Refer to Table 3--for required orifice)Burner Orifice #441011352as requiredOrifices for High Altitude Conversion (Not included in kit)(Refer to Table 2--for required orifice)(Refer to Table 3--for Alternate Input or 80,000required orifice)Burner Orifice #411096942as required Burner Orifice #431011377as required Burner Orifice #441011352as required Burner Orifice #451011353as required Burner Orifice #461011744as required244106106803Specifications subject to change without notice.General InformationThis kit is for conversion of furnaces equipped with Single StageHoneywell VR8205S Series gas valves from propane gas to natural gas.Before the furnace can be operated with natural gas,the low inlet pressure switch must be removed.A gas valve conversion kit must be installed and main burner orifices must be replaced with orifices in this kit or with properly sized orifices for high altitude or alternate input ordered separately.The orifices provided in this kit are stamped to indicate the size (twist drill number).The parts list specifies the size orifices supplied in the pare the size marking on the orifices with the sizes as listed in the parts list.Make sure you have the correct main burner orifices.Extreme care is used to assure that this kit contains the proper orifices.Oversized orifices could result in hazardous conditions,especially if the venting is inadequate.For that reason,we recommend that the installer check the size of the orifice with a new twist drill of the correct size.This procedure assures that the orifices provided are the correct size.InstallationDisassemblyRefer to Figure 1and the following steps .1.After disconnecting power and gas supply to the furnace,remove the access door,exposing gas valve and burner compartment.2.Disconnect the yellow wire harness from the two terminals on the Propane switch,the air pressure switch,and furnace harness.3.Reconnect yellow furnace harness wire to air pressure switch.See furnace wiring label.4.Disconnect gas line from fitting assembly so manifold assembly can be removed.5.Disconnect wiring at gas valve.Be sure to note the proper location of any and all electrical wiring disconnected.6.Remove the four (4)screws holding the manifold and gas valve to the manifold supports.Do Not discard any screws.7.Carefully remove the manifold assembly and remove fitting assembly from the gas valve.8.Unscrew the Propane pressure switch from the bushing.1.Remove the Propane (silver)orifices burner orifices from the manifold assembly and replace them with the Natural gas (brass)furnished in the conversion kit or called out in Table 2or Table 3.(See Figure 2).2.T ighten the orifices so they are seated and gas tight about 11/8″(28.2mm)from the face of the orifice to the back of the manifold pipe (Figure 3).Make sure orifice is installed straight so that it forms a right angle (90°)to the manifold.High Altitude InstallationGas input rate on the furnace rating plate is for installation at up to 2000′.The#42burner orifices supplied in this kit are sized for Natural Gas at full rate ONLY,for use between0--2000′elevation.Do not use them above2000′(except when noted by Table2or Table3).Orifices for conversion at high altitude and alternate input must be ordered from Service Parts.Standard Input:Units may be installed at full input rating(25,000BTUH per heat exchanger)when installed at altitudes up to2000′.80,000BTUH model and Alternate Input(Conversions): Units may be installed at full input rating(20,000BTUH per heat exchanger)when installed at altitudes up to8000′.See furnace Installation Instructions to determine if alternate inputconversion is permitted.In the USA,for furnaces fired on full rate,the input rating for altitudes above2000′(8,000′for80,000BTUH and alternate input)must be derated by2%for each1000′above sea level(see Table2and Table3)In Canada,the input rating for altitudes above2000′(8,000′for 80,000BTUH)must be reduced by5%for altitudes of2000′to4500′above sea e the2001to3000column in Table2and Table3.Alternate BTUH Input Ratings(USA Only)CAUTION:See furnace Installation Instructions to verify that model could be converted to alternate input.The input rating of these furnaces can be changed from the standard input rating to the alternate input rating shown in Table1, by changing the main burner orifices.Changing of burner orifices MUST be done by a qualified service technician.See section on changing orifices.Table1Alternate Input Ratings,USA ONLY.BTUHStandardRatingBTUHAlternateRatingNatrualGasOrifice* 50,00040,000#4475,00060,000#44100,00080,000#44125,000100,000#44*See Table3for High AltitudeMANIFOLD PRESSURE AND ORIFICE SIZE FOR HIGH ALTITUDE APPLICATIONSTable2NATURAL GAS MANIFOLD PRESSURE(in wc)25,000BTUH per burner Except90%40k,60k,80k BTUH models and alternate input ratingsMEAN ELEVATION FEET ABOVE SEA LEVELHEATINGVALUEat ALTITUDE BTU/CU.FT.0to20002001to30003001to40004001to50005001to60006001to70007001to8000 OrificeNo.ManifoldPressureOrificeNo.ManifoldPressureOrificeNo.ManifoldPressureOrificeNo.ManifoldPressureOrificeNo.ManifoldPressureOrificeNo.ManifoldPressureOrificeNo.ManifoldPressure700------------------------------------------------41 3.7725----------------------------------------41 3.741 3.4750----------------------------------------41 3.542 3.6775--------------------------------41 3.642 3.642 3.3800------------------------41 3.642 3.742 3.442 3.1825----------------41 3.741 3.442 3.542 3.242 2.9850----------------41 3.542 3.642 3.342 3.042 2.8875--------41 3.642 3.642 3.442 3.142 2.842 2.6900--------42 3.742 3.442 3.242 2.942 2.742 2.592541 3.742 3.542 3.342 3.042 2.842 2.544 3.395041 3.542 3.342 3.142 2.942 2.642 2.444 3.197542 3.742 3.242 2.942 2.742 2.544 3.245 3.6 100042 3.542 3.042 2.842 2.642 2.445 3.745 3.4 105042 3.242 2.742 2.544 3.345 3.6----------------110043 3.642 2.544 3.245 3.6------------------------Conversion:1in wc=.25kPaNOTE:Natural gas data is based on0.60specific gravity.For fuels with different specific gravity consult the National Fuel Gas Code ANSI Z223.1--2006/NFPA 54--2006or National Standard of Canada,Natural Gas And Propane Installation Code CSA B149.1--05.NOTE:Bold number indicates factory shipped size.344106106803Specifications subject to change without notice.444106106803Specifications subject to change without notice.Table 3NATURAL GAS MANIFOLD PRESSURE (in wc)20,000BTUH per burner FOR THE 90%40k,60k,80k BTUH model and alternate input ratingsHEATING VALUE at ALTITUDE BTU/CU.FT .MEAN ELEVATION FEET ABOVE SEA LEVEL0to 20002001to30003001to 40004001to 50005001to 60006001to70007001to8000Orifice No.Manifold Pressure Orifice No.Manifold Pressure Orifice No.Manifold Pressure Orifice No.Manifold Pressure Orifice No.Manifold Pressure Orifice No.Manifold Pressure Orifice No.Manifold Pressure 700--------------------------------------------------------725--------------------------------------------------------750----------------------------------------41 3.641 3.6775--------------------------------41 3.441 3.441 3.4800------------------------42 3.542 3.542 3.542 3.5825----------------42 3.342 3.342 3.342 3.342 3.3850----------------42 3.142 3.142 3.142 3.142 3.1875--------43 3.543 3.643 3.643 3.643 3.643 3.6900--------43 3.343 3.443 3.443 3.443 3.443 3.492544 3.744 3.744 3.744 3.744 3.744 3.744 3.795044 3.544 3.544 3.544 3.544 3.544 3.544 3.597544 3.344 3.344 3.344 3.344 3.344 3.344 3.3100044 3.244 3.244 3.244 3.244 3.244 3.244 3.21050463.6463.6463.6463.6463.6----------------110046 3.346 3.346 3.346 3.3------------------------Conversion:1in wc =.25kPaNOTE:Natural gas data is based on 0.60specific gravity.For fuels with different specific gravity consult the National Fuel Gas Code ANSI Z223.1--2006/NFPA54--2006or National Standard of Canada,Natural Gas And Propane Installation Code CSA B149.1--05.NOTE:Bold number indicates factory shipped size.NOTE:In the USA,for furnaces fired on full rate,the input rating for altitudes above 2000′(8,000′for 80,000BTUH and alternate input)mustbe derated by 2%for each 1000′above sea level (see Table 2and Table 3).In Canada,the input rating for altitudes above 2000′(8,000′for 80,000BTUH)must be reduced by 5%for altitudes of 2000′to 4500′above sea e the 2001to 3000column in Table 2and Table 3.Gas Valve ConversionConversion of Honeywell VR8205S Gas Valve using Natural Gas Conversion Kit#396222.1.Remove the regulator cap screw and pressure regulator adjusting screw.(See Figure 4and Figure 5)2.Remove the existing regulator spring from the regulator housing.3.Insert the replacement spring (silver color)contained in this kit into regulator housing.4.Install the pressure regulator adjusting screw and give it six (6)full turns.This will set the manifold pressure close to required setting for normal operation.5.Replace the regulator cap screw.6.Attach the Caution Label contained in the kit to the Gas Valve where it can be readily seen.If Propane Conversion Label is already there,replace with new Natural Gas Caution Label.544106106803Specifications subject to change without notice.ReassemblyReassemble all parts in reverse order as removed .Attach Natural Gas Conversion Label next to the furnace rating plate or to the front exterior of the furnace.If Propane Gas Conversion Label is there replace with Natural Conversion Label.•Manifold Assembly --Be sure to engage the main burnerorifices in the proper openings in the burners.•Verify the ignitor is inthe correct location.(See Figure 6)•Testing for leaks --After reassembly,turn the gas on andcheck all joints for gas leaks using a soapy solution.All leaks must be repaired immediately.Gas Pressure•Gas input to burners MUST NOT exceed the rated input shown on rating plate.•Do NOT allow minimum gas supply pressure to vary downward.Doing so will decrease input to furnace.Refer to Table 4for gas supply and manifold pressures.Table 4Gas Pressures (in wc)Gas Type Supply PressureManifold Pressure RecommendedMax.Min.Natural7144.53.5**See Table 2or Table 3conversion:1in wc =.25kPaImportant Notes•Measured input can NOT exceed rated input.•Any major change in gas flow requires changing burner orifice size .Start--up and Check--out1.Remove the plug from the Inlet Pressure Tap on gas valve and install a manometer.(See Figure 4)2.Open manual gas line valve to unit.Check for gas leaks and correct as necessary.Check supply pressure,7in wc recommended,4.5in wc minimum,14in wc maximum.If not within these limitations DO NOT OPERATE FURNACE,contact gas supplier.3.Close manual gas line valve to unit,remove manometer and replace inlet pressure tap plug.Gas Valve Adjustment1.With the gas valve knob or switch in the OFF position,remove the pressure tap plug from the outlet end of the valve,and connect a ”U”tube manometer to the pressure port.(Figure 4)2.Turn the gas valve knob or switch to the ON position andrestore electrical power to unit.Cycle the main burner on and off several times to stabilize the pressure regulator diaphragm.This MUST be done before an accurate pressure reading can be obtained.3.With the main burner on,read the pressure gauge.Forappropriate reading see Table 2or Table 3.Turn pressure regulator adjusting screw clockwise to increase or counterclockwise to decrease manifold pressure.Burner Input must not exceed nameplate rating.Refer to Section “Checking Input Rate”.4.Turn gas valve to OFF.Remove the pressure gauge andreplace the pressure tap plug and pressure regulator cap screw.5..Start the main burners and check pressure tap plug for gasleaks.6.With gas valve on,observe furnace through two or morecomplete cycles to be sure all controls are operating.Checking Input RateChecking Burner Input Using A Meter To check the BTU inputrate,the test hand on the meter should be timed for at least one revolution and the input determined from this timing.Refer to Section 11,Table II.I.1of the National Fuel Gas Code for converting test hand readings to cubic feet per hour.ExampleNatural Gas BTU ContentNo.of SecondsPer HourCubic Feet Per HourBTU Per Hour 1,0003,6004875,000Example:1,000BTU x 3,600/48=75,000BTU/hour644106106803Specifications subject to change without notice.*High Altitude Input Rate =Nameplate Sea Level Input Rate x (Multiplier)ElevationHigh Altitude Multiplier Natural Gas*Standard InputHigh Altitude Multiplier Natural Gas*80,000BTUH InputModel High Altitude Multiplier Natural Gas*Alternate Input0′-2000′ 1.00 1.000.802001′-3000′0.95 1.000.803001′-4000′0.93 1.000.804001′-5000′0.91 1.000.805001′-6000′0.89 1.000.806001′-7000′0.87 1.000.807001′-8000′0.851.000.80*Based on mid--range of elevation.Main Burner Flame CheckCheck for the following:(See Figure 7)•Stable and blue flames.Dust may cause orange tips or wispsof yellow,but flames MUST NOT have solid,yellow tips.•Flames extending directly from burner into heat exchanger.•Flames do NOT touch sides of heat exchangerIf any problems with main burner flames are noted,it may be necessary to adjust gas pressures or check for drafts.High Altitude Derated Unit LabelThe derated label supplied with the conversion kit must be completed and affixed to the furnace near the rating plate.Fill in the manifold pressure,orifice size and revised input rate.Refer to Table 2or Table 3provided to determine the proper orifice part numbers for ordering purposes.Verify System OperationUpon completion of all conversion procedures,perform the following steps to attach appropriate labels and verify the system operation.1.Locate the Natural Gas Conversion Label next to the furnace rating plate.Replace Propane Gas Conversion Label if there.2.Fill out and attach the Field Conversion Label to the front exterior of the furnace.Replace any existing Field Conversion Label.3.Turn the thermostat to its lowest temperature setting or to OFF if equipped with a System Select Switch.4.Turn the gas valve control knob or switch to ON.5.Reinstall all access panels.6.Turn ON all electrical power to the unit.7.Set the thermostat to the desired temperature and the System Select Switch to HEAT.8.Observe unit operation through two (2)complete heating cycles.See “Sequence of Operation”in furnace installation instructions.。
美式空气净化器系列1000:中文版说明书
A C1711/90fies the air in less than 10 min (1)virus, allergen& pollutant removal (3,4,7) just one push of a button, the air purifier filters the invisible viruses, allergens pollutants in your home to keep it clean and safe. It purifies quickly andffectively, thanks to its clean air delivery rate (C A DR) of 300 m³/h.Seamless operationUltra-quiet and no light disturbanceSuperior performanceFast purification suitable for spaces of up to 78 m²Filters 99.97% particles as small as 0.003 micronsRemoves up to 99.9% of viruses and aerosols from the airProfessional grade sensor for intelligent purificationTested and certified for quality you can trustEffortless controlSmart filter replacement indicatorEasy maintenanceSeamless operationLow energy consumptionEffortless controlHighlightsFast puri fication for 78 m²Powerful air flow circulation e ffectively covers spaces up to 78 m and distributes ultra clean air in every corner of the room . This boosts clean air delivery to 300 m /hr C A DR , purifying 20 m in only 10 min . (1)99.97% particleremovalA 3-layer filtration with NanoProtect HEP A,active carbon and pre -filter makes sure you are protected from bacteria , pollen , dust , PM 2.5,pet danderand gases .The NanoProtect HEP A technology not only captures pollutants , but it uses an electrostatic charge to attract them ,enabling it to purify the air faster than a HEP A H 13 filter that is medically used . (5)Up to 99.9% virusremovalThe VitaShield technology captures aerosols and particles smaller than the smallest known Coronavirus (6). Virtually nothing escapes from VitaShield - It deactivates viruses and traps them inside . Tested independently by A irmid health -group to remove up to 99.9% of viruses and aerosols from the air (2). A lso , tested for corona virus (7).Scan andvisualizeThe professional grade A eraSense sensor accurately scans the air 1000x a second to detect harmful pollutants and intelligently chooses the right speed for every environment .It displays the air quality in real time , showing level of allergens and PM 2.5 in numerical form ,as well as with an intuitive color ring .Quality you cantrustPhilips puri fiers go through 170 mandatory and strict inspection tests before they are released from our factory and are certi fied by the European Centre for A llergy ResearchFoundation . They are subjected to rigorous life and durability tests for continuous operation (24/7).Ultra -quiet & nodisturbanceIn sleep mode , the puri fier operates in near silence for clean air while you sleep . Both air quality index and the light on the UI can be dimmed or turned o ff to avoid any light disturbance .Low energyconsumptionThanks to its energy e fficient design , the air puri fier runs at max . 27 W power . This isequivalent to an incandescent light bulb . It is compliant with a highly e fficient grade of strict global standard .Smart filterindicatorThe air puri fier accurately calculates filterlifetime based on pollution level and operation time . It noti fies you when the filter needs replacement , for easy maintenance .EasymaintenanceThe air puri fier is designed for easier cleaning ,using the compact and simple cylindrical plastic body . It uses a 3in 1 integrated filter so no need to change each filter separately .SpecificationsEnergy efficiencyMax. power consumption: 27 WStand-by power consumption: <=0.2 W Voltage: 100-240 VMaintenanceRecommended filter change: 12 months (8) Replacement filter: FY1700/30 Service: 2-year worldwide guarantee Weight and dimensionsProduct dimensions (W x D x H):273*273*486 mmDimension of packaging (LxWxH):326*326*535 mmWeight incl. packaging: 5.4 kgWeight of product: 4.1 kgColor(s): White, Light greyPerformanceC A DR (Particle, GB/T): 300 m³/h m³/hRoom size (NRCC): Up to 78 m²Filtration: HEP A, A ctive Carbon, Pre-filterA ir quality sensor(s): PM2.5 particleParticle filtration: 99.97% at 0.003 micronsA llergens filtration: 99.99%Virus & aerosol filtration: <99.9%UsabilityMin. sound level (Sleep mode): 18 dBMax. sound level (Turbo mode): 50 dBCord length: 1.8 mA utomatic modeSleep modeManual speed settings: 4 (Sleep, Speed 1, 2,Turbo)A ir quality feedback: Color, Numerical (PM2.5,I A I)A uto-ambient light* (1)From the air that passed through the filter, it is atheoretical time for one-time cleaning calculated bydividing the room size of 48m³by C A DR 300m³/h(assuming the room is 20m²in floor area and 2,4 m inheight).* (2)Microbial Reduction Rate Test conducted at A irmidHealth group Ltd. tested in a 28.5m³test chambercontaminated with airborne influenza A(H1N1), in Turbomode after 10-20 mins. A n air purifier by itself does notprotect against Covid-19, but can be part of the plan toprotect yourself and your family (US EnvironmentalProtection A gency)* (3)From the air that passes through the filter. Tested withNaCl aerosol by iUT A according to DIN71460-1* (4)From the air that passes through the filter, tested withbirch pollen dust on filter media according to SOP350.003 of the A ustrian OFI institute* (5)NanoProtect HEP A filter material provides lower airflow resistance than the material from a HEP A H13 filter,enabling a Philips air purifier with NanoProtect to delivera higher Clean A ir Delivery Rate (C A DR) than with anequivalently-sized certified HEP A H13 filter (Testconducted by Philips Mar 2016).* (6)From the air that passes through the filter, tested withNaCl aerosol by iUT A according to DIN71460-1.Supporting literature for the size of Coronaviruses have asize of approx. 0.08 - 0.22 micron :MacLachlan, Dubovi,Fenner's Veterinary Virology (5th Ed.), A cademic Press,2017, Ch. 24 Pages 435-461* (7)Microbial Reduction Rate Test at external lab, in a testchamber contaminated with human coronavirus (HCoV-229E) aerosols, with Philips HEP A NanoProtect filter.* (8)Recommended lifetime is calculated based on thePhilips users’ average usage time and the WHO urbanoutdoor pollution level data. A ctual lifetime is impactedby usage environments and frequencies.© 2023 Koninklijke Philips N.V.A ll Rights reserved.Specifications are subject to change without notice. Trademarks are the property of Koninklijke Philips N.V. or their respective owners.Issue date 2023‑10‑06 Version: 6.6.1E A N: 87 20389 00396 7 。
Philips 空气净化器 Series 4000i 产品说明书
Series 4000iRemove 99.9% particles@3nm PM2.5, allergens & gas display Up to 48 m2Auto, Sleep mode & appAC4558/00Healthier air, alwaysDecorate your home with clean healthy air Philips’ new air purifier Series 4000i is designed to complement your home's design with the efficient and stylish solution to reduce PM2.5, harmful gases and allergens in your home.Intelligent purification for healthy air, alwaysSmart sensingIntelligent auto purificationFast and effective purificationFast purification resultSuperior particle removal performanceSuperior gas removal performanceCertified Allergy friendlySee and control your air anytime, anywhereReal time air quality feedbackSimple 4-color display ring for easy monitoringTrack, monitor and control with your smartphone appSuperior design & user friendlyClassic minimalist product designUltra-quiet operationHighlightsSmart sensingA smart sensor detects even the slightest change in air and automatically adjusts fan speed for optimal purification performance.Intelligent auto purificationOffers 4 specially designed auto modes for you to optimize your air according to your needs:general, pollution, gas and allergen, creating a safe haven for you in your house.Fast purification resultWith a particle CADR (clean air delivery rate) of 400m3/hour, it cleans the air in a room of 20m2 in less than 8 minutes*.Superior particle removalPowered by the upgraded VitaShieldtechnology, the air purifier efficiently removes 99.97% of particles as small as 0.003um (800times smaller than PM2.5), including PM2.5,viruses, bacteria, pollen, dust, and pet dander*.It makes sure you breathe healthy air even during heavy pollution season.Superior gas removalEquipped with upgraded VitaShieldtechnology, the air purifier effectively reduces harmful gases such as formaldehyde, VOCs,and odors and maintains them at safe levels*.Activated carbon nano-sized pores form an absorption surface area the size of 30 football fields for a high efficiency and a lifetime of TVOCs purification* with a formaldehyde at CADR 270m3/hr.Certified Allergy friendlyWith a specially designed, extra-sensitive allergen mode it effectively detects andreduces allergens like pollen. Certified Allergy-friendly by ECARF (European Center for Allergy Research Foundation).Real time air quality feedbackReal-time PM2.5 numerical display, indoor harmful gases & allergen index, makinginvisible air quality visible, to make sure you always stay in control – Powered by: PM2.5sensor benchmarked professional grade sensor,provide real time feedback of yourindoor air quality. Accurate and advanced gas sensor that can detect harmful gases and display the level of potential harmful gases.Air quality in 4 colorsThe color ring provides an additional visual cue ranging from blue (good) to red (poor) to present the indoor air quality.Connected to appUsing the app you can control your air purifier anywhere, anytime. Check the air quality in the app to get reassurance wherever you are,and to compare your indoor air quality with the outdoor air quality. You can also use the app to change the fan speed and to check the filter status.Classic minimalist designClassic minimalist product design for trendy homes, easily fits any home interior style. Stay healthy, stay in style.Ultra-quiet operationIn sleep mode, display lights are dimmed and the purifier operates in near silence for clean air while you sleep — certificated by Quietmark.SpecificationsPerformanceRoom size: 28-48 m²CADR (Particle): 400* m³/hCADR (Formaldehyde): 270* m³/h0.3µm particle removal: 99.97 %Ultra fine particle removal: as small as 3* nm Filters out H1N1 Virus: 99.9* %Filters out bacteria: 99.9* %Particle CCM: P4Formaldehyde CCM: F4Recommended filter life time: 12 months Sound Power: 34-64 dB(A)FeaturesVitaShieldAeraSense technologyAir Quality feedback: NumericalGas sensorPM2.5 sensorModes: 4 auto modesFan speed: Sleep, 1, 2, TurboChild lock Healthy air lock & AlertLight control: On/OffMotor: DCDesign and finishingColor(s): WhiteColor of control panel: ChampagneControl panel type: Touch panelTechnical specificationsVoltage: 220 VFrequency: 50/60 HzCord length: 1.6 mPower: 65 WWeight and dimensionsWeight of product: 9.6 kgWeight incl. packaging: 10.66 kgDimension of product (LxWxH): 358 x 253 x672Dimension of packaging (LxWxH): 463 x 313 x770 mmLogistic data12NC code: 8834 558 00710EAN F-box: 8710103878407ReplacementIntegrated filter: FY4152Country of originMade in: ChinaSustainabilityPackaging: > 90% recycled materialsStand-by power consumption: < 2 WUser manual: 100% recycled paperService2-year worldwide guarantee* It is a theoretical time for one-time cleaning calculatedby dividing its CADR 400m3/h by the room size of 48m3 (assuming the room is 20 m2 in floor area and 2.4 min height.)* Tested by third party according to GB/T 18801-2015.* The filter was tested with NaCl aerosol by iUTAaccording to DIN71460-1.* Microbial Reduction Rate Test conducted at AirmidHealthgroup Ltd. tested in a 28.5m3 test chambercontaminated with airborne influenza A(H1N1).* Activated carbon media measured by 3rd party lab,shows most of the pores size are 1nm – 2nm, and ACsurface area of the activated carbon is 1070m2/g.Filters' total Active Carbon surface area of 1 footballfield size is based on int'l standard football field size* Tested by GMT in 30m3 chamber according toGB21551.3-2010, (Staphylococcus albsp) 8032 astesting bacteria.© 2020 Koninklijke Philips N.V.All Rights reserved.Specifications are subject to change without notice. Trademarks are the property of Koninklijke Philips N.V. or their respective owners.Issue date 2020‑05‑26 Version: 8.1.1。
海尔电子科技有限公司 空气净化器 用户手册说明书
6. Clean the filter. 7. Re-insert the filter in the supply hose. 8. Screw the water connection back on. 9. Check the water connection for leaks. 10.Restore the power supply. 11.Switch the appliance on.
bile device and follow the instructions.
2. Scan the QR code with the Home Connect app.
Overview of water hardness settings
You can find an overview of the water hardness values that can be selected here. A table of country-specific units can be found in the instruction manual.
Programme
1) Duration [h:min] 2) Energy [kWh] 3) Water [l]
Intensive 70°
1) 1:55 - 2:05 2) 1,090 - 1,200 3) 10,5 - 13,0
Auto 45-65°
1) 1:35 - 2:40 2) 0,650 - 1,100 3) 7,0 - 14,5
gether and lift
1
the coarse filter
out .
Cleaning spray arms
1. Unscrew the upper spray arms and
Philips 空气净化器 4000i 系列说明书
4000i SeriesPurifies rooms up to 73 m²610 m³/h clean air rate (CADR) HEPA & Active Carbon filter Connected with CleanHome+ appAC3858/50Purifies the air in less than 5 min (1) 99.9% virus, allergen & pollutant removal (3,4,7) With just one push of a button, the air purifier filters the invisible viruses, allergens or pollutants in your home, to keep it clean and safe. It purifies quickly andeffectively, thanks to its clean air delivery rate (CADR) of 610 m³/h.Superior performanceHigh performance suitable for rooms of up to 73 m²HEPA filter captures 99.97% of particles of 0.003 micronsRemoves up to 99.9% of viruses and aerosols from the airSmart sensors for intelligent purificationThoroughly tested for quality you can trustSeamless operationSleep mode with ultra-quiet operationAuto-ambient lightingLow energy consumptionEffortless controlAir quality displayTrack and control with the appAuto mode and 4x manual speed levelsSmart filter indicatorHighlightsHigh performance360° airflow intake effectively covers rooms up to 73 m ² and distributes clean air in everycorner of the room. This boosts performance to 610 m ³/hr (2) CADR (Clean Air Delivery Rate). It cleans 20 m ² in only 5 min. (1)99.97% particle removal3-layer filtration with NanoProtect HEPA,active carbon filter and pre-filter captures 99.97% of ultra-fine particles as small as0.003 microns (4), so you are safe from PM2.5,bacteria, pollen, dust, pet dander, gas and other pollutants (7). Certified by the European Centre for Allergy Research Foundation.Up to 99.9% virus removalCaptures aerosols including those which may contain respiratory viruses. Testedindependently by airmid health-group to remove up to 99.9% of viruses and aerosols from the air (3). Also tested for coronavirus (5).Intelligent sensorsScans the air 1000x a second to detect ultra fine-particles. Reports the air quality in real time, and intelligently chooses the right speed for your home (in auto mode).Quality you can trustPhilips purifiers go through 170 mandatory and strict inspection tests before releasing from factory. They are subjected to rigorous life and durability tests, for continuous operation 24/7.Ultra-quiet operationIn Sleep mode, display lights are dimmed, and the purifier operates in near silence for clean air while you sleep. Certified by Quiet Mark.Auto-ambient lightingThe display light automatically adjusts according to the environment in your room,giving you all the benefits without any of the disturbance.Low energy consumptionThanks to its energy efficient design, the air purifier runs at max. 60 W power. This is equivalent to one standard light bulb.Air quality displaySee the real-time air quality in your home at a glance. The display shows the level ofallergens, gases and PM2.5 in numerical form,as well as with an intuitive color ring.SpecificationsPerformanceCADR (Particle, GB/T): 610 m³/hRoom size (G/BT): Up to 73 m²Air quality sensor(s): PM2.5 particle, Gas Filtration: HEPA, Active Carbon, Prefilter Particle filtration: 99.97% at 0.003 microns Allergens filtration: 99.99%Virus & aerosol filtration: 99.9%UsabilityMin. sound level (Sleep mode): 34 dB Max. sound level (Turbo mode): 66 dB Automatic modeSleep modeManual speed settings: 4 (Sleep, 1, 2, Turbo)Air quality feedback: Color ring, numericalAuto-ambient lightCord length: 1.8 mEnergy efficiencyMax. power consumption: 60 WStand-by power consumption: <2 WVoltage: 230 VConnectivityApp, connects via Wi-Fi: Clean Home+Smartphone compatibility: iPhone andAndroid devicesVoice control: Alexa, Google Home (7)Weight and dimensionsWeight: 9.4 kgDimensions (L*W*H): 310*310*718Color(s): White, GreyMaintenanceRecommended filter change: 3 years (6)Replacement filter: FY4440/30Service: 2-year worldwide guarantee* (1)From the air that passes through the filter, it is atheoretical time for one-time cleaning calculated bydividing its CADR 610 m³/h by the room size of 48 m³(assuming the room is 20 m² in floor area and 2.4 m inheight).* (2)CADR is tested by a certified third party lab,according GB/T18801-2015. Following improvements inour testing method and production quality control, weupgraded the CADR values of our products.* *If you buy a product where this info is not updated onthe box yet, rest assured that the product performs atthe higher specification mentioned online.* (3) Microbial Reduction Rate Test conducted at AirmidHealth group Ltd. tested in a 28.5m³ test chambercontaminated with airborne influenza A(H1N1).* An air purifier by itself does not protect against Covid-19, but can be part of plan to protect yourself and yourfamily (US Environmental Protection Agency)* (4)From the air that passes through the filter, testedwith NaCl aerosol by iUTA according to DIN71460-1.* (5)Microbial Reduction Rate Test at external lab, in atest chamber contaminated with avian coronavirus (IBV)aerosols, with Philips HEPA NanoProtect filter.* (6)The recommended service life for the device is basedon a theoretical calculation of the average annualregional values of harmful air particles outdoors anddaily use of the air purifier for 16 hours in automaticmode.* (7)Tested on the filter media for 1 pass efficiency at5.33cm/s air flow, by a third party lab./From the air thatpasses through the filter, tested to JISB 9908-2015* (8)Alexa and Google Home availability depends onyour location© 2021 Koninklijke Philips N.V.All Rights reserved.Specifications are subject to change without notice. Trademarks are the property of Koninklijke Philips N.V. or their respective owners.Issue date 2021‑05‑12 Version: 10.0.1。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Operation and Maintenance Manual
FIVE YEAR (5) LIMITED WARRANT
ALLERAIR
Warrants their home use 4, 5, 6 & 8000 series units to be free from defects in materials and workmanship under normal use and service for a period of 5 years from date of purchase. The obligation of this warranty shall be limited to repairing or replacing any part of the unit which we agree is defective in materials or workmanship under normal use and service during the five year period commencing with the date of purchase, sent with the original or sufficient packaging protection. Please call toll free 1-888-852-8247 for detailed return instructions. This five year warranty is in lieu of all other express warranties, obligations or liabilities (expect those implied warranties, which in some states cannot be excluded). No agent, representative, dealer or employee of the company has the authority to increase or alter the obligations of this warranty. This warranty shall not apply to any unit which has been modified, repaired or altered in any way without the express written consent of AllerAir Industries Inc. This warranty does not apply to any expendable parts of the unit. In no case shall AllerAir Industries Inc. be liable for any consequential damages for breach of this or any other warranty expressed or implied whatsoever. This warranty is limited to the original retail purchaser and is not transferable. Kindly address any questions regarding this warrany to AllerAir Industries Inc.
Models Exec Models 2"** Exec Models 2.5"** Vocarb Models 2"** Vocarb Models 2.5"** D Exec Models 3" D Vocarb Models 3" DX Exec Models 3.5" DX Vocarb Models 3.5" DS Models 3" MCS Models 2"
Models 2" Canister** 2.5" Canister** D Models DX Models
STEP 1
Turn power off and Unplug the unit. Lay unit up-side down.
Remove all four screws with a screwdriver.
STEP 2
STEP 3
Gently grasp wheels.
Pull back pre-filter slightly, remove screws from top of filter.
STEP 7
STEP 8
Remove carbon filter lid.
STEP 9
Pour out old bulk carbon until totally empty.
First remove the Carbon filter by placing thumbs on the inner side of the filter. Then pull up gently to remove filter. To refill the Carbon Canister without changing the HEPA filter go to Step 7 on page 5
STEP 5
STEP 10
Pour the new bulk carbon into the carbon canister.
Use a custom refill funnel from AllerAir. Save time and spillage and ensure an even distribution of carbon. Available from AllerAir Call Toll free 1-888-852-8247
Put lid back on and align the lid holes with pre-drilled holes on the canister.
Press down on the lid until securely tight.
Put back the screws in the pre-drilled holes.
Operation:
Your unit is shipped fully assembled and ready for use. Plug into 120V-15amp outlet. For best results situate your unit close to your sitting, sleeping or work area. NOTE: Please save your packaging. Original packaging will be required for all warranty returns.
6000 A6FCB320 A6FCB325 A6FCB220 A6FCB225 A6FCB330 A6FCB230 A6FCB335 A6FCB235 A5FCB620 A6FCB120
8000 A8FCB320 A8FCB325 A8FCB220 A8FCB225 A8FCB330 A8FCB230 A8FCB335 A8FCB235
Model # Serial #
4000 - 5000 - 6000 - 8000 Series Air Purifiers
AllerAir Industries Inc. Toll free: 1-888-852-8247 / Fax: 1-877-688-2193
The 4000 - 5000 - 6000 - 8000 Series - Air Purifier
Congratulations, you are moments away from fresher, cleaner indoor air. Your new AllerAir unit will combat many of the chemicals, gases, odors and particles responsible for poor indoor air quality, and in turn, health concerns such as allergies, asthma, sick building syndrome and multiple chemical sensitivity. As with any air cleaner, proper maintenance of your unit is a vital part of keeping it operating at peak efficiency.
8
AllerAir Industries Inc. Toll free: 1-888-852-8247 / Fax: 1-877-688-2193
1
TO REMOVE THE CARBON CANISTER
REFILING THE CARBON CANISTER WITH NEW BULK CARBON
EXTENDED WARRANTY
AllerAir's five year warranty is extendible to 10 years. Kindly call for information. AllerAir manufactures the most effective air purification systems, using the latest technology available today. These are distributed worldwide for commercial, residential, institutional and industrial use. The units meet all the higest standards required for safety and health.