EasyChem Plus 全自动离子分析仪
合集下载
相关主题
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
EasyChem Plus: powerful functions in a compact layout
Pre and post run sample dilution Calibrants automatic preparation from concentrated solutions Samples throughput: 30-40 samples/hour Flowcell length: 10, 20 or 40 mm Full QA/QC functions allow data validation
EasyChem Plus: examples of applications reported in scientific literature
Nitrogen retention in natural Mediterranean wetlands affected by agricultural runoff
Ammonia (N) Orthophosphate (P) Nitrate + nitrite (N) Nitrite (N) Silicate (SiO2) Chloride (Cl-) Chromium 6+ Iron (soluble) Phenols (manual Aluminum (*) distillation) Copper (*) Cyanide (manual Magnesium (*) distillation) Alkalinity Nickel (*) Hardness
Total Nitrogen (N) Total Phosphorus (P) Total Kjieldhal Nitrogen (N) Phosphorus Olsen COD Cyanide (with distilation) Phenols (with distillation)
EasyChem Plus: different applications
EasyChem Plus: the software
Typical measuring sequence programming includes: method setup method setup - calibration method setup - limits and QC worklist preparation start analysis run analysis display results
EasyChem Plus: main foreign references
Severn Trent Laboratories, Valparaiso (USA): n.2 units Ifremer (France) Lyon University (France) Brisbane University (Australia) Turner Tech Laboratories, Illinois (USA) Philip Morris, Chester MA (USA) Washington State University (USA) California State University (USA) Southern Illinois University (USA)
EasyChem Plus: start analysis
EasyChem Plus: run analysis
EasyChem Plus: display results
EasyChem Plus: the software advanced features
EasyChem provides to the operator the most advanced features available for lab analyzers: pre and post-run sample dilution automatic preparation of calibrants on-line check during measurements QC controls management and long-term storage for data validation results reprocessing for calibration, Gain/Drift and carry over correction
EasyChem Plus: analyzer overview
The reaction cuvettes: located around the sample tray sample and reagents are introduced in the cuvette through the needle + syringe pump cuvettes temperature can be controlled up to 50 oC a proper wash cycle between samples assures no carry over
Analysis of water, sea water, soil and plant extracts, wine and other industrial samples 59 positions samples tray including controls and calibrants cups Up to 18 reagents cooled tray Up to 9 wavelenghts with automatic selection
Phytoremediation to remove nutrients and improve eutrophic stormwaters using water lettuce Laboratory study highlights the key influences of stormwater sediment thickness and bioturbation by tubificid worms on dynamics of nutrients and pollutants in stormwater retention systems Temporal and spatial variations of nutrients in the Ten Mile Creek of South Florida, USA and effects on phytoplankton biomass Short-term Variability of Physico-chemical Parameters and the Estimated Transport of Filterable Nutrients and Chlorophyll-a in the urbanised Coombabah lake and Coombabah Creek System, Southern Moreton Bay, Australia
ห้องสมุดไป่ตู้
EasyChem Plus: analyzer overview
The reagent tray: it contains up to 16 reagents, 50 ml volume temperature is controlled by a Peltier cooler a computer controlled needle connected to an high precision micro-syringe pump allows samples and reagents pick-up optional cadmium column can be installed on the tower
(*) Methods under development
Color (Pt/Co unit) Calcium
EasyChem Plus: applications requiring preliminary sample handling
Water, soil and plants liquid extracts Available methods:
EasyChem Plus: method setup
EasyChem Plus: method setup - calibration
EasyChem Plus: method setup - limits and QC
EasyChem Plus: worklist preparation
EasyChem Plus Discrete Analyzer for laboratory analysis of chemical compounds
北京易科泰生态技术有限公司
EasyChem: routine analysis of inorganic compounds becomes easy
Immediate shut-down
Windows based software QC control QC actions
EasyChem Plus: main applications available
Water matrix: shallow, sea water, waste water Available methods, full automated:
Wine analysis using enzymatic kits Pharmaceutical analysis for production control Tobacco analysis including the following parameters:
Ammonia (N) Nitrate + nitrite (N) Nitrite (N) Nicotine Reducing sugar
EasyChem Plus: analyzer overview
The colorimeter: as soon as the analysis program ends, a second needle is activated driven through a peristaltic pump placed on the right side of the analyzer temperature controlled flow-cell 10,20 or 40 mm flow-cell length automatic selection of wavelength, 9 wavelengths available as standard
EasyChem Plus: analyzer overview
Reagents and samples dosing station Reaction cuvettes Dispensing syringe Measuring station Reagent tray Wash water bottle Colorimter and Flow Cell
EasyChem Plus: features and benefits
Easy to use Low reagents consumption Flexibility immediate start-up
No specific experience required Low reagents and disposable costs; lower costs for reagents discharge Individual parameters list selectable on each sample No time waste or problems to reach the hydraulic equilibrium No washing procedure required Easy to use and learn, short training, specifically designed for chemists Up to five levels, QC results stored and plotted in a QC chart IF QC out of tolerance warning or even stop the analyzer
Samples tray
Peristatlic pump
EasyChem Plus: analyzer overview
The sample tray: located in the centre of the working area 59 samples, calibrants and controls can be easily placed (vial volume: 4 ml) positions reserved to standars identified by a red line samples are identified by a progressive number