216314_水池侧壁及底板配筋计算表
经典工程量计算工具之室内水池计算表
名称标高段钢筋种类数量钢筋类型钢筋大小钢筋识别码钢筋长度根数附加长度下料长度根数小水池顶横水平底筋121017.6297.620912101 4.1227 4.12027竖水平底筋12101 6.9719 6.9701912101 1.8219 1.82019F轴处面筋12101 1.8224 1.8202412101 2.74524 2.74524G轴处面筋12101 1.34524 1.345244轴外边面筋12101 1.34520 1.3452012101 2.44524 2.445244轴内边面筋12101 1.34520 1.3452012101 1.04515 1.04515横面层构造筋11617.3117.300111161 3.810 3.80010竖面层构造筋1161 6.6517 6.650171161 5.258 5.2508马凳筋121250.57260.57026板角加强筋(大)42101 1.327 1.320742101 1.327 1.320742101 3.0924 3.09024板角加强筋(小)421010.74530.7453421010.74530.7453421010.8890.8809检修孔21810.66120.660122161 2.4723 2.47232181 1.2165 1.216521810.83450.83452181 1.1963 1.19632161 1.0722 1.0722大水池顶横水平底筋12101 4.1710 4.17010121017.67267.67026121018.92198.92019竖水平底筋12101 4.077 4.0707121019.22199.220191210110.871910.87019H轴处面筋12101 1.29557 1.29557G轴处面筋12101 2.1748 2.17048F-G轴中间处面筋12101 2.1748 2.17048近4轴处面筋12101 2.2758 2.27058近5轴处面筋12101 1.9769 1.97069横面层构造筋31617.3587.350831618.688.6008竖面层构造筋21618.978.9007216110.55610.5506马凳筋121250.57710.57071板角加强筋(5轴)821010.98550.9855821010.98550.985582101 2.1411 2.14011板角加强筋(中间)42101 1.1456 1.145642101 1.1456 1.1456421012.6142.60014室内水池钢筋识别码:1为主筋,2为箍筋,3为拉结筋,4为中间箍筋,5为不规则钢筋,6机械接头水池顶板板角加强筋(4轴)32101 1.1856 1.185632101 1.1856 1.185632101 2.7215 2.72015板角加强筋(4轴)221010.90540.9054221010.90540.905422101 1.9310 1.93010板角加强筋(4轴)321010.80840.8084321010.80840.808432101 1.8610 1.86010检修孔11810.66120.660121161 2.4723 2.47231181 1.2165 1.216511810.83450.83451181 1.1963 1.19631161 1.0722 1.0722KL1面筋221818.72428.7242底筋222218.41428.4142接头22622箍筋2182 1.45451 1.45451KL2面筋1218110.27210.2742底筋122219.96429.9642接头12622箍筋1182 1.45459 1.45459KL3面筋1218111.92211.9242底筋1222111.61211.6142接头12622箍筋1182 1.45467 1.45467水池底板主钢筋4212113.058313.05483马凳筋121250.671520.670152生活水池侧壁:SQ2长为2.5+1.5m,SQ1长为33.897m。
水池侧壁及底板配筋
四、挠度验算
α Eρ =ESAS/ECbh0 短期刚度BS=ESASh02/(1.15ψ +0.2+6α Eρ ) (N· mm2) 长期刚度Bl=BS*MS/(MS+Ml) (N· mm2) 挠度限值 l0/200 11.83 挠度f=5MSl02/48Bl (mm) 验算f ≤ l0/200
一、原始数据
板厚h (mm) 板长l (mm) 混凝土强度等级C 构件环境 250 3600 25 2
说明:1:一类,2:二类a,3:二类b,4:三类a,5:三类b
钢筋型号 受力钢筋强度设计值fy (N/mm2) 钢筋弹性模量ES (N/mm2) 构件受力特征系数α cr 纵向受拉钢筋表面特征系数ν 保护层厚度as
三、裂缝验算
短期弯矩MS (KN· m) ρ te=AS/0.5bh 41.58 长期弯矩Ml (KN· m) ρ te实际取值(ρ te≥0.01) 41.58 2 受拉区纵筋等效直径deq=d/ν (mm) 167.34 σ sk=MS/η h0AS (N/mm ) ψ =1.1-0.65ftk/ρ teσ sk 应变不均匀系数ψ 实际取值(0.2≤ψ ≤1.0) 0.607 最外层受拉钢筋外边缘至受拉底边距离c (20≤c≤65) (mm) 最大裂缝宽度ω max=α crψ σ sk/ES(1.9c+0.08deq/ρ te) (mm) 最大裂缝宽度限值ω lim (mm) 验算ω max ≤ ω lim 0.25
三、截面配筋
设计弯距M (KN· m) 截面抵抗矩系数α S=M/α 1fcbh02 γ S=(1+(1-2α S)1/2)/2 计算钢筋面积AS=M/γ Sfyh0 (mm2) Asmin 37.8 0.0794 0.9586 938.9 1350 钢筋直径d (mm) 钢筋间距s (mm) 钢筋实际配筋面积AS (mm2) 是否满足 Asmax
水池侧壁及底板配筋自动计算表
2
20 150 2094.4 满足
)/2
钢筋面积AS=M/γSfyh0 (mm ) 三、裂缝验算 短期弯矩MS (KN·m) 长期弯矩Ml (KN·m) σsk=MS/ηh0AS (N/mm ) ψ=1.1-0.65ftk/ρteσsk
2
பைடு நூலகம்729.5
71.00 36.00 84.71 -0.442
ρte=AS/0.5bh ρte实际取值(ρte≥0.01) 受拉区纵筋等效直径deq=d/ν (mm)
应变不均匀系数ψ实际取值(0.2≤ψ≤1.0)
0.0084 0.0100 28.6 0.200 20 0.05 满足
最外层受拉钢筋外边缘至受拉底边距离c (20≤c≤65) (mm) 最大裂缝宽度ωmax=αcrψσsk/ES(1.9c+0.08deq/ρte) (mm) 最大裂缝宽度限值ωlim (mm) 四、挠度验算 αEρ=ESAS/ECbh0 短期刚度BS=ESASh0 /(1.15ψ+0.2+6αEρ) 长期刚度Bl=BS*MS/(MS+Ml) 挠度f=5MSl0 /48Bl
1/2 2 2 2
300 2.0E+05 2.1 0.7
14.3 1.00 2.01
水池结构计算书
水池计算一. 底板计算上部结构及侧壁:3100kN覆土:1200 kN挑土:0.5*(18+46)*4.2*18=2420KN底板:0.5*9.6*23.6*25=2830KNGk=9550 kN基地平均反力 P=9550/23.6*9.6=42KPaLy=6,lx=8,按双向板计算,四边简支。
M yK=0.062×42×6²=94KN-MM xK=0.0317×42×6²=48KN-M底板厚500mm计算As=1100mm²实配X向Φ18@180(1414mm2)计算As=1500mm²实配Y向Φ18@150(1696mm2)裂缝计算:计算最大裂缝宽度wmax:wmax=2.1ψ*σsk(1.9c+0.08deq/ρte)/Es=0 .19 mm 小于最大裂缝宽度限值wlim=0 .2mm 裂缝计算满足要求。
二. 侧壁计算1. 荷载取值以池内无水,池外有土计算地面堆积荷载 f1= 20×1/3=6.7KN/㎡(均布荷载)土压力 f2= 1/3×8×4.2=11.2KN/㎡(三角形荷载)地下水压力 f3=10×3.7=37KN/㎡(三角形荷载)2. 荷载计算(以池内无水,池外有土计算)①荷载设计值 0 ~ 58KN/㎡(三角形荷载)9.4KN/㎡(均布荷载)②荷载标准值 0 ~ 48.2KN/㎡(三角形荷载)6.7KN/㎡(均布荷载)3.池壁1(以池内无水,池外有土计算)Ly=3.7,lx=8,按单向板计算,一端固定一端铰接。
1)三角形荷载My=0.0298×58×3.7²=24KN-M M YK=0.0298×48.2×3.7²=20KN-MM0Y=-1/15×58×3.7²=-53KN-M M0YK=-1/15×48.2×3.7²=-44KN-M2)均布荷载My=0.07×9.4×3.7²=9KN-M M YK=0.0298×6.7×3.7²=7KN-MM0Y=-1/8×9.4×3.7²=-16KN-M M0YK=-1/15×6.7×3.7²=-11KN-M 荷载总计:My=33KN-M M YK=27KN-MM0Y=-69KN-M M0YK=-55KN-M侧壁厚300mm计算As=660mm²实配X向Φ14@200(770mm2)计算As=920mm²实配Y向Φ14@150(1026mm2)裂缝计算:计算最大裂缝宽度wmax:wmax=2.1ψ*σsk(1.9c+0.08deq/ρte)/Es=0 .18 mm小于最大裂缝宽度限值wlim=0 .2mm 裂缝计算满足要求。
水池钢筋计算
ft
0.91 1.10 1.27 1.43 1.57 1.71 1.80 1.89 1.96 2.04 2.09 2.14 2.18 2.22
普通钢筋 种类 HPB235 HRB335 HRB400 RRB400
钢筋强度设计值
fy
210 300 360 360
fy′
210 300 360 360 Φ
As=ρ*b*h0 φ12@100 5% 合格
<
混凝土强度 等级 C15 C20 C25 C30 C35 C40 C45 C50 C55 C60 C65 C70 C75 C80
混凝土强度设计值
fc
7.20 9.60 11.90 14.30 16.70 19.10 21.10 23.10 25.30 27.50 29.70 31.80 33.80 35.902C20 NhomakorabeaHPB235
fc fy
9.60 210
N/mm
2
N/mm2
H h b γ γQ 3 Ⅲ γo γd 运用期持久状况 M
3.00 300 1000 10 1.10 级 级 1.00 1.20 ψ 49.50
m mm mm kN/m3
1.00 kN·m M=γo*ψ*γQ*1/6*γ*H3
二级环境 c h0 αs ξ ξb 双筋 单筋 ρ ρmin 0.440% 0.272% ρ=ξ*f c /f y 35 260 0.09153 0.09615 0.614 mm mm h0=h-c-d/2 αs=γd*M/(f c *b*h02) ξ=1-(1-2αs)1/2
水池池壁钢筋计算
一、 材料强度 混凝土 钢筋 二、 内力计算 水池高度 池壁宽度 单宽 水的重力密度 分项系数 建筑物级别 结构安全等级 结构重要性系数 结构系数 设计状况 最大弯矩设计值 三、 配筋计算 处于露天,长期通水 保护层 截面有效高度 截面抵抗矩系数 相对受压区高度 相对界限受压区高度 ξ>ξb ξ≤ξb 配筋率 受弯构件最小配筋率 ρ>ρmin ρ≤ρmin 钢筋截面面积 选用钢筋截面面积 As As′ (As′-As)/As 1142.86 1131 1.04% mm2 mm
板钢筋用量计算表
1板面筋1 2.65 2.6500.394 1.0442板底筋1 4.45 4.4500.394 1.7533板底筋1 4.45 4.4500.394 1.7534板底筋1 4.45 4.4500.394 1.7535板底筋1 4.45 4.4500.394 1.7536板底筋1 4.45 4.4500.394 1.7537板底筋1 4.45 4.4500.394 1.7538板底筋1 4.45 4.4500.394 1.7539板底筋1 4.45 4.4500.394 1.75310板底筋1 4.45 4.4500.394 1.75311板底筋1 4.45 4.4500.394 1.75312板底筋1 2.95 2.9500.394 1.16213板底筋1 3.25 3.2500.394 1.28114板底筋2 4.458.9000.394 3.50715板底筋1 4.45 4.4500.394 1.75316板底筋1 4.45 4.4500.2220.98817板底筋1 4.45 4.4500.394 1.75318板底筋7 4.4531.1500.39412.27319板底筋1 1.81 1.8100.3940.71320板底筋1 1.81 1.8100.2220.40221板底筋2 4.398.7800.222 1.94922板底筋324.45142.4000.39456.106板钢筋用量计算表工程名称:板钢筋用量计算表2500757544504450445044504450445044504450445044504450445044504450445044502950325018101810439023板底筋3 6.2518.7500.3947.38824板底筋33 2.9597.3500.39438.35625板底筋231 4.45########0.394405.01226板底筋26 3.5592.3000.39436.36627板底筋260.8522.1000.3948.70728板底筋26 2.6568.9000.39427.14729板底筋70 1.75122.5000.22227.19530板底筋35 2.6592.7500.22220.59131板底筋1 5.05 5.0500.222 1.12132板底筋9 5.0545.4500.39417.90733板底筋4 2.058.2000.394 3.23134板底筋350.8529.7500.222 6.60535板底筋1 5.05 5.0500.222 1.12136板底筋12 2.6531.8000.39412.52937板底筋364 4.45########0.394638.20138板底筋176.25106.2500.39441.86339板底筋13 1.0613.7800.6178.50240构造分布筋4 2.489.9200.222 2.20241板面筋13 1.7522.7500.3948.96442构造分布筋7 2.4817.3600.222 3.85443板面筋10.850.8500.3940.33544板面筋20 2.6352.6000.39420.72445构造分布筋11 2.4827.2800.222 6.05646板面筋1 1.50 1.5000.3940.59147构造分布筋4 2.489.9200.394 3.90848板面筋13 1.5019.5000.61712.03249构造分布筋62.4814.8800.2223.3031600757524807575135075751350757544504450295062506250355026502650265017505050505050502050248024802480248024808508509107575700757550构造分布筋72.1214.8400.2223.29451板面筋7 1.339.3100.394 3.66852构造分布筋52.1210.6000.222 2.35353板面筋13 1.2115.7300.394 6.19854构造分布筋52.1210.6000.222 2.35355板面筋1 2.05 2.0500.3940.80856板面筋40 2.65106.0000.39441.76457板面筋2 2.63 5.2600.6173.24558板面筋1 1.50 1.5000.6170.92659板面筋1 1.51 1.5100.3940.59560板面筋10 1.5115.1000.394 5.94961构造分布筋61.14 6.8400.222 1.51862板面筋62.6515.9000.6179.81063构造分布筋11 1.1412.5400.222 2.78464板面筋6 1.7510.5000.394 4.13765构造分布筋71.147.9800.222 1.77266板面筋6 1.06 6.3600.617 3.92467构造分布筋41.14 4.5600.222 1.01268板面筋 1.510.0000.6170.00069构造分布筋24 1.1427.3600.222 6.07470板面筋1 1.51 1.5100.3940.59571板面筋1 2.65 2.6500.394 1.04472板面筋60.91 5.4600.394 2.15173构造分布筋41.14 4.5600.222 1.01274板面筋12.212.2100.3940.87125007575250075751350757511807575106075751900757524807575136075751360757513607575250075751600757513607575206075752120212021201140114011401140114011409107575760757575板面筋6 1.297.7400.394 3.05076构造分布筋51.14 5.7000.222 1.26577板面筋62.0812.4800.394 4.91778板面筋81.149.1200.2222.02579板面筋1 1.29 1.2900.6170.79680板面筋10.610.6100.3940.24081构造分布筋91.1410.2600.2222.27882板面筋6 1.14 6.8400.394 2.69583构造分布筋51.14 5.7000.222 1.26584板面筋1 1.14 1.1400.6170.70385板面筋12.05 2.0500.3940.80886板面筋6 2.6515.9000.6179.81087构造分布筋11 1.1412.5400.222 2.78488构造分布筋51.14 5.7000.3942.24689板面筋12 1.7521.0000.61712.95790构造分布筋141.1415.9600.222 3.54391板面筋1 1.91 1.9100.3940.75392板面筋6 1.9111.4600.6177.07193构造分布筋81.149.1200.2222.02594板面筋1 1.14 1.1400.6170.70395板面筋61.458.7000.394 3.42896板面筋242.6563.6000.61739.24197构造分布筋44 1.1450.1600.22211.13698板面筋10.760.7600.6170.46999构造分布筋101.1411.4000.2222.53125007575250075751600757575751140757519307575114075751900757517607575176075751140114011401140114011401140114011401140145046075759907575990757599075756107575100板面筋18 1.7531.5000.61719.436101构造分布筋211.1423.9400.222 5.315102板面筋362.6595.4000.61758.862103构造分布筋66 1.1475.2400.22216.703104构造分布筋121.1413.6800.222 3.037105板面筋182.6547.7000.61729.431106构造分布筋331.1437.6200.2228.352107板面筋9 1.5113.5900.6178.385108板面筋12 1.7521.0000.61712.957109构造分布筋14 1.1415.9600.2223.543110构造分布筋91.1410.2600.2222.278111板面筋1 1.15 1.1500.3940.453112板面筋2 1.06 2.1200.617 1.308113板面筋13 1.3117.0300.394 6.710114构造分布筋52.5012.5000.222 2.775115板面筋1 1.45 1.4500.3940.571116板面筋10.840.8400.3940.331117板面筋78 2.65206.7000.617127.534118构造分布筋882.50220.0000.22248.840119板面筋39 1.4556.5500.61734.891120构造分布筋182.5045.0000.2229.990121板面筋2 1.45 2.9000.617 1.789122板面筋39 1.7568.2500.39426.891123板面筋10.840.8400.6170.518124板面筋521.7591.0000.61756.14716007575250075752500757525007575160075751600757516007575136075751000757511607575130075751300757513007575114011401140114011401140250025002500910757569075756907575125构造分布筋422.50105.0000.22223.310126板面筋3 1.75 5.2500.617 3.239127板面筋2 1.06 2.1200.3940.835128板面筋13 1.5119.6300.61712.112129构造分布筋62.5015.0000.2223.330130板面筋11 1.5116.6100.61710.248131板面筋20 2.6553.0000.61732.701132板面筋130.9111.8300.6177.299133构造分布筋42.5010.0000.222 2.220134板面筋10.910.9100.6170.561135板面筋1 1.15 1.1500.6170.710136板面筋10.610.6100.2220.135137构造分布筋25 2.5062.5000.39424.625138板面筋13 1.3817.8750.3947.043139板面筋133.9551.3500.39420.232构件编号:NB11板面筋11 1.5016.5000.394 6.5012构造分布筋1 1.35 1.3500.2220.3003构造分布筋2 3.30 6.6000.222 1.4654板面筋17 4.4575.6500.39429.8065板底筋34 4.45151.3000.39459.6126构造分布筋2 4.509.0000.222 1.9987构造分布筋7 2.3016.1000.222 3.5748板面筋12 1.2114.5200.394 5.7219构造分布筋112.3025.3000.222 5.61710板面筋121.7521.0000.61712.95713507575106075752500757516007575160075751360757513607575100075754450445025002500250025001375395013503300450023002300910757576075757607575460757511板底筋11.81 1.8100.3940.71312板面筋22.63 5.2600.6173.24513板底筋14.39 4.3900.394 1.73014板面筋1 1.14 1.1400.3940.44915构造分布筋12.50 2.5000.2220.55516板面筋13 2.0526.6500.39410.50017板面筋17 1.5125.6700.39410.11418板底筋14.45 4.4500.394 1.75319板面筋1 2.65 2.6500.617 1.63520板面筋13 1.5119.6300.61712.11221板面筋26 6.25162.5000.39464.02522板底筋26 2.6568.9000.39427.14723板底筋1 2.95 2.9500.394 1.16224板底筋1 4.45 4.4500.394 1.75325构造分布筋12 2.5030.0000.222 6.66026板面筋32 2.6584.8000.61752.32227构造分布筋26.3012.6000.222 2.79728板面筋1 1.45 1.4500.6170.89529板面筋39 2.65103.3500.61763.76730构造分布筋6 2.5015.0000.222 3.33031构造分布筋8 1.7013.6000.222 3.01932板面筋110.9110.0100.617 6.17633板底筋150.8512.7500.222 2.83134板底筋114.4548.9500.39419.28635板面筋11.511.5100.6170.93224807575136075752500757525007575250075751360757513607575190075751300757544504450445029501810439062502650250025002500630017008509907575760757536板面筋44 2.65116.6000.39445.94037板底筋11 4.4548.9500.39419.28638构造分布筋222.1046.2000.22210.25639板面筋3 2.657.9500.617 4.90540板底筋42.6510.6000.394 4.17641板面筋1 1.06 1.0600.6170.65442板底筋66.2537.5000.39414.77543板面筋3 1.51 4.5300.617 2.79544板面筋11 1.0611.6600.6177.19445板面筋11 1.5116.6100.61710.24846构造分布筋122.1025.2000.222 5.59447板面筋110.9110.0100.3943.94448板面筋22 3.5578.1000.39430.77149构造分布筋102.1021.0000.222 4.66250板面筋3 1.293.8700.617 2.38851板面筋1 1.15 1.1500.3940.45352板面筋1 1.15 1.1500.3940.45353板面筋33 1.7557.7500.61735.63254构造分布筋12 2.1025.2000.222 5.59455板底筋11 1.7519.2500.3947.58556构造分布筋5 2.1010.5000.222 2.3315715.05 5.0500.222 1.12158板面筋1 1.45 1.4500.3940.57159板面筋11 1.7519.2500.3947.58560构造分布筋142.1029.4000.2226.5271600757525007575250075751600757513607575136075751140757510007575130075751000757544506250355026501750505021002100210021002100210091075759107575760757561板底筋55 4.45244.7500.39496.43262构造分布筋6 1.7010.2000.222 2.26463板底筋15 1.7526.2500.222 5.82864构造分布筋21 2.1044.1000.2229.79065板底筋22 2.6558.3000.39422.97066构造分布筋7 1.6411.5010.222 2.55367板面筋2 1.75 3.5000.617 2.16068板底筋4 5.0520.2000.3947.95969构造分布筋20.90 1.8000.2220.40070板面筋10.610.6100.6170.37671构造分布筋20.90 1.8000.2220.40072板面筋51.457.2500.6174.473构件编号:NB11板面筋13 1.7522.7500.3948.9642板面筋17 4.4575.6500.22216.7943构造分布筋5 2.5012.5000.222 2.7754板底筋20 4.4589.0000.22219.7585构造分布筋62.5015.0000.2223.3306板面筋1 1.50 1.5000.6170.9267板底筋1 2.95 2.9500.394 1.1628板面筋20 2.6553.0000.39420.8829板底筋13 4.4557.8500.39422.79310构造分布筋7 2.5017.5000.222 3.88511板底筋39 4.45173.5500.39468.37912板底筋20 4.4589.0000.39435.06613构造分布筋442.50110.0000.22224.42014板面筋12.652.6500.3941.04425007575250075751600757513507575160075751300757544504450445044504450445029502650175050502500250025002500170021001643900900460757515板面筋1 1.51 1.5100.6170.93216板面筋13 1.7522.7500.61714.03717板面筋13 2.6534.4500.61721.25618板面筋13 1.9124.8300.61715.32019构造分布筋6 2.5015.0000.222 3.33020板底筋32 4.45142.4000.39456.10621板底筋32 4.45142.4000.39456.10622板底筋324.45142.4000.39456.10623板面筋1 1.91 1.9100.617 1.17824板面筋32 2.6584.8000.61752.32225板底筋32 4.45142.4000.39456.10626板底筋4 2.6510.6000.394 4.17627板底筋56.2531.2500.39412.31328板面筋1 1.51 1.5100.6170.93229构造分布筋3 6.3018.9000.222 4.19630板面筋32 1.7556.0000.61734.55231构造分布筋55 6.30346.5000.22276.92332构造分布筋60.93 5.5500.222 1.23233板底筋1 4.45 4.4500.394 1.75334板底筋1 4.45 4.4500.394 1.75335板底筋1 4.45 4.4500.394 1.75336构造分布筋30.93 2.7750.2220.61637板底筋152.6539.7500.39415.66238板面筋5 1.06 5.3000.6173.27039板底筋106.2562.5000.39424.62540板面筋51.517.5500.6174.658757525007575250075751600757516007575136075751360757513607575176075751760757544504450445044504450445044506250625026502650250063006300925925910757541板面筋1 1.06 1.0600.6170.65442构造分布筋220.9320.3500.222 4.51843板底筋1 4.45 4.4500.394 1.75344构造分布筋20.93 1.8500.2220.41145板面筋30 2.6579.5000.61749.05246板底筋52.0510.2500.394 4.03947板面筋1 1.45 1.4500.6170.89548构造分布筋11 4.5049.5000.22210.98949构造分布筋14.50 4.5000.2220.99950板面筋23 2.6560.9500.61737.60651板面筋23 1.5134.7300.61721.42852板面筋7 1.4510.1500.617 6.26353板面筋14 2.6537.1000.61722.89154构造分布筋1 1.36 1.3600.2220.30255构造分布筋6 1.368.1600.222 1.81256构造分布筋11 1.3614.9600.222 3.32157板底筋14 4.4562.3000.39424.54658构造分布筋6 1.368.1600.222 1.81259板底筋12.05 2.0500.3940.80860板面筋9 2.6523.8500.61714.71561板底筋35.0515.1500.394 5.96962板面筋61.519.0600.6175.590构件编号:NB11板底筋23 6.25143.7500.39456.6382板面筋1 2.65 2.6500.394 1.0443构造分布筋64.5027.0000.2225.9942500757525007575250075752500757525007575757513607575136075751300757513007575445044506250505020502050450045004500136013601360136092592591075754板面筋23 2.6560.9500.61737.6065构造分布筋6 4.5027.0000.222 5.9946构造分布筋7 1.7712.4040.222 2.7547板底筋1 6.25 6.2500.394 2.4638板底筋14 4.4562.3000.39424.5469构造分布筋1 2.58 2.5760.2220.57210构造分布筋12.50 2.5000.2220.55511板面筋13 1.5119.6300.3947.73412构造分布筋1 2.50 2.5000.2220.55513板底筋32 4.45142.4000.39456.10614板底筋1 6.25 6.2500.394 2.46315板面筋2 1.513.0200.617 1.86316板面筋32 1.7556.0000.61734.55217构造分布筋36.3018.9000.222 4.19618板面筋32 2.6584.8000.61752.32219构造分布筋11 4.5049.5000.22210.98920构造分布筋64.5027.0000.2225.99421板面筋3 2.657.9500.617 4.90522板底筋1 4.45 4.4500.394 1.75323板底筋1 4.45 4.4500.394 1.75324板面筋13 1.5119.6300.61712.11225板面筋1 1.75 1.7500.617 1.08026构造分布筋62.5015.0000.2223.33027板面筋2 2.65 5.3000.617 3.27028构造分布筋12 2.5030.0000.222 6.66029板底筋14.454.4500.3941.7532500757525007575250075752500757516007575160075751360757513607575136075754450445044504450445062506250250025002500250045004500450063001772257630构造分布筋1 2.50 2.5000.2220.55531板底筋1 4.45 4.4500.394 1.75332构造分布筋3 2.507.5000.222 1.66533板面筋39 2.65103.3500.39440.72034板面筋65 2.65172.2500.617106.27835板面筋39 1.5158.8900.61736.33536板底筋65 6.25406.2500.394160.06337板面筋13 1.5119.6300.61712.11238板面筋1 1.75 1.7500.617 1.08039构造分布筋55 2.50137.5000.22230.52540构造分布筋6 2.5015.0000.222 3.33041构造分布筋3 2.507.5000.222 1.66542构造分布筋6 2.5015.0000.222 3.33043构造分布筋11.60 1.6000.2220.35544板面筋2 1.51 3.0200.617 1.86345构造分布筋6 1.609.6000.2222.13146板底筋6 4.4526.7000.39410.52047板底筋21.603.2000.2220.71025007575160075751360757513607575136075754450445062502650250025002500250025002500160016001600。
水池配筋计算
执行规范:《混凝土结构设计规范》(GB 50010-2002), 本文简称《混凝土规范》《建筑地基基础设计规范》(GB 50007-2002), 本文简称《地基规范》《给水排水工程构筑物结构设计规范》(GB50069-2002), 本文简称《给排水结构规范》《给水排水工程钢筋混凝土水池结构设计规程》(CECS138-2002), 本文简称《水池结构规程》-----------------------------------------------------------------------1 基本资料1.1 几何信息水池类型: 无顶盖半地上长度L=18.300m, 宽度B=8.500m, 高度H=3.850m,底板底标高=-3.800m池底厚h3=350mm, 池壁厚t1=350mm,底板外挑长度t2=400mm注:地面标高为±0.000。
(平面图) (剖面图)1.2 土水信息土天然重度18.00 kN/m3 , 土饱和重度20.00kN/m3, 土内摩擦角20度修正后的地基承载力特征值fa=100.00kPa地下水位标高-1.500m,池内水深3.500m, 池内水重度10.00kN/m3,浮托力折减系数1.00, 抗浮安全系数Kf=1.051.3 荷载信息活荷载: 地面15.00kN/m2, 组合值系数0.90恒荷载分项系数: 水池自重1.20, 其它1.27活荷载分项系数: 地下水压1.27, 其它1.27活荷载准永久值系数: 顶板0.40, 地面0.40, 地下水1.00, 温湿度1.00考虑温湿度作用: 池内外温差10.0度, 弯矩折减系数0.65, 砼线膨胀系数1.00(10-5/°C)1.4 钢筋砼信息混凝土: 等级C30, 重度25.00kN/m3, 泊松比0.20保护层厚度(mm): 池壁(内30,外30), 底板(上30,下30)钢筋级别: HRB335, 裂缝宽度限值: 0.20mm, 配筋调整系数: 1.00按裂缝控制配筋计算构造配筋采用混凝土规范GB50010-20022 计算内容(1) 地基承载力验算(2) 抗浮验算(3) 荷载计算(4) 内力(考虑温度作用)计算(5) 配筋计算(6) 裂缝验算(7) 混凝土工程量计算3 计算过程及结果单位说明: 弯矩:kN.m/m 钢筋面积:mm2裂缝宽度:mm计算说明:双向板计算按查表恒荷载:水池结构自重,土的竖向及侧向压力,内部盛水压力.活荷载:顶板活荷载,地面活荷载,地下水压力,温湿度变化作用.裂缝宽度计算按长期效应的准永久组合.3.1 地基承载力验算3.1.1 基底压力计算(1)水池自重Gc计算池壁自重G2=1598.62kN底板自重G3=1554.26kN水池结构自重Gc=G2+G3=3152.89 kN(2)池内水重Gw计算池内水重Gw=4804.80 kN(3)覆土重量计算池顶覆土重量Gt1= 0 kN池顶地下水重量Gs1= 0 kN底板外挑覆土重量Gt2= 1026.72 kN底板外挑地下水重量Gs2= 430.56 kN基底以上的覆盖土总重量Gt = Gt1 + Gt2 = 1026.72 kN基底以上的地下水总重量Gs = Gs1 + Gs2 = 430.56 kN(4)活荷载作用Gh地面活荷载作用力Gh2= 331.20 kN活荷载作用力总和Gh=Gh2=331.20 kN(5)基底压力Pk基底面积: A=(L+2×t2)×(B+2×t2)=19.100×9.300 = 177.63 m2基底压强: Pk=(Gc+Gw+Gt+Gs+Gh)/A=(3152.89+4804.80+1026.72+430.56+331.20)/177.630 = 54.87 kN/m23.1.2 结论: Pk=54.87 < fa=100.00 kPa, 地基承载力满足要求。
水池侧壁及底板配筋计算(结构计算表格)
板厚h (mm)
板长l (mm) 混凝土强度等级
500
7000 C25
受力钢筋强度设计值fy (N/mm2)
300
钢筋弹性模量ES (N/mm2)
构件受力特征系数αcr 纵向受拉钢筋表面特征系
数ν
2.0E+05 2.1 0.7
ቤተ መጻሕፍቲ ባይዱ
二、常规数据
混凝土轴心抗压设计值fc (N/mm2) 系数α1
σsk=MS/ηh0AS (N/mm2)
84.71
受拉区纵筋等效直径 deq=d/ν (mm)
ψ=1.1-0.65ftk/ρteσsk
-0.266
应变不均匀系数ψ实际取 值(0.2≤ψ≤1.0)
最外层受拉钢筋外边缘至受拉底边距离c (20≤c≤65) (mm) 最大裂缝宽度ωmax=αcrψσsk/ES(1.9c+0.08deq/ρte) (mm)
最大裂缝宽度限值ωlim (mm) 0.20
验算ωmax ≤ ωlim
0.0084 0.0100
28.6
0.200 20
0.05 满足
四、挠度验算
αEρ=ESAS/ECbh0 短期刚度长B期S刚=E度SABSl=h0B2/S(*1M.1S5/ψ(M+S0+.M2+l)6α(NEρ·m)m(2N) ·mm2)
挠度f=5MSl02/48Bl (mm)
3.85
挠度限值 l0/200
验算f ≤ l0/200
0.033 1.42E+14 9.41E+13
35.0
满足
11.9
混凝土弹性模量EC (N/mm2)
2.8E+04
1.00 板有效高度h0=h-40 (mm) 460
水池配筋计算
执行规范:《混凝土结构设计规范》(GB 50010-2002), 本文简称《混凝土规范》《建筑地基基础设计规范》(GB 50007-2002), 本文简称《地基规范》《给水排水工程构筑物结构设计规范》(GB50069-2002), 本文简称《给排水结构规范》《给水排水工程钢筋混凝土水池结构设计规程》(CECS138-2002), 本文简称《水池结构规程》-----------------------------------------------------------------------1 基本资料1.1 几何信息水池类型: 无顶盖半地上长度L=18.300m, 宽度B=8.500m, 高度H=3.850m, 底板底标高=-3.800m池底厚h3=350mm, 池壁厚t1=350mm,底板外挑长度t2=400mm注:地面标高为±0.000。
(平面图) (剖面图)1.2 土水信息土天然重度18.00 kN/m3 , 土饱和重度20.00kN/m3, 土内摩擦角20度修正后的地基承载力特征值fa=100.00kPa地下水位标高-1.500m,池内水深3.500m, 池内水重度10.00kN/m3,浮托力折减系数1.00, 抗浮安全系数Kf=1.051.3 荷载信息活荷载: 地面15.00kN/m2, 组合值系数0.90恒荷载分项系数: 水池自重1.20, 其它1.27活荷载分项系数: 地下水压1.27, 其它1.27活荷载准永久值系数: 顶板0.40, 地面0.40, 地下水1.00, 温湿度1.00考虑温湿度作用: 池内外温差10.0度, 弯矩折减系数0.65, 砼线膨胀系数1.00(10-5/°C) 1.4 钢筋砼信息混凝土: 等级C30, 重度25.00kN/m3, 泊松比0.20保护层厚度(mm): 池壁(内30,外30), 底板(上30,下30)钢筋级别: HRB335, 裂缝宽度限值: 0.20mm, 配筋调整系数: 1.00按裂缝控制配筋计算构造配筋采用混凝土规范GB50010-20022 计算内容(1) 地基承载力验算(2) 抗浮验算(3) 荷载计算(4) 内力(考虑温度作用)计算(5) 配筋计算(6) 裂缝验算(7) 混凝土工程量计算3 计算过程及结果单位说明: 弯矩:kN.m/m 钢筋面积:mm2裂缝宽度:mm计算说明:双向板计算按查表恒荷载:水池结构自重,土的竖向及侧向压力,内部盛水压力.活荷载:顶板活荷载,地面活荷载,地下水压力,温湿度变化作用.裂缝宽度计算按长期效应的准永久组合.3.1 地基承载力验算3.1.1 基底压力计算(1)水池自重Gc计算池壁自重G2=1598.62kN底板自重G3=1554.26kN水池结构自重Gc=G2+G3=3152.89 kN(2)池内水重Gw计算池内水重Gw=4804.80 kN(3)覆土重量计算池顶覆土重量Gt1= 0 kN池顶地下水重量Gs1= 0 kN底板外挑覆土重量Gt2= 1026.72 kN底板外挑地下水重量Gs2= 430.56 kN基底以上的覆盖土总重量Gt = Gt1 + Gt2 = 1026.72 kN基底以上的地下水总重量Gs = Gs1 + Gs2 = 430.56 kN(4)活荷载作用Gh地面活荷载作用力Gh2= 331.20 kN活荷载作用力总和Gh=Gh2=331.20 kN(5)基底压力Pk基底面积: A=(L+2×t2)×(B+2×t2)=19.100×9.300 = 177.63 m2基底压强: Pk=(Gc+Gw+Gt+Gs+Gh)/A=(3152.89+4804.80+1026.72+430.56+331.20)/177.630= 54.87 kN/m2 3.1.2 结论: Pk=54.87 < fa=100.00 kPa, 地基承载力满足要求。
水池侧壁及底板配筋计算表程序(带公式)
P(KN)
0
距悬臂端距离a(mm)
固定端支座反力RB=P (KN)
0
距悬臂端距离 x (mm) 0
460
弯距Mx(KN·m)
0.00
0.00
500
920 0.00
距固定端距离b(mm)
1380 0.00
1840 0.00
4100
2300 0.00
三、一段均部荷载q
q (KN/m)
0
距悬臂端距离d(mm)
一、截面信息 板长l(mm)
4600
二、一个集中力P
P(KN)
0
距悬臂端距离a(mm)
固定端支座反力RB=P (KN)
0
距悬臂端距离 x (mm) 0
460
弯距Mx(KN·m)
0.00
0.00
500
920 0.00
距固定端距离b(mm)
1380 0.00
1840 0.00
4100
2300 0.00
二、一个集中力P
均部中点距悬臂端距离a(mm)
300
固定端支座反力RB=qc (KN)
0
距左端距离 x (mm)
0
460
弯距Mx(KN·m)
0.00
0.00
100
均部范围c(mm)
均部中点距固定端距离b(mm)
920 0.00
1380 0.00
1840 0.00
400 4300
2300 0.00
三、一段均部荷载q
q (KN/m)
2760 35.04
2760 0.00 35.04
3220 0.00
3220 0.00
3220 0.00
水池侧壁计算
0.0077
σsk=MS/ηh0AS(N/mm2)
171.43
ρte实际取值(ρte≥0.01)
0.0100
ψ=1.1-0.65ftk/ρteσsk
0.338
受拉区纵筋等效直径deq=d/ν(mm)
14.0
应变不均匀系数ψ实际取值(0.2≤ψ≤1.0)
0.338
最外层受拉钢筋外边缘至受拉底边距离c (20≤c≤65) (mm)
是否满足
满足
裂缝验算
短期弯矩MS(KN·m)
174.63
ρte=AS/0.5bh
0.0157
σsk=MS/ηh0AS(N/mm2)
187.92
ρte实际取值(ρte≥0.01)
0.0157
ψ=1.1-0.65ftk/ρteσsk
0.657
受拉区纵筋等效直径deq=d/ν(mm)
20.0
应变不均匀系数ψ实际取值(0.2≤ψ≤1.0)
1.00
混凝土抗拉标准值ftk(N/mm2)
2.01
池壁有效厚度h0=h-60 (mm)
340
二、弯矩计算
水压荷载下迎水侧最大弯矩标准值MBwK=pwl2/15 (KN·m/m)
174.63
水压荷载下非迎水侧最大弯矩标准值MmaxwK=0.0298pwl2(KN·m/m)
78.06
三、截面配筋
⒈迎水侧
计算弯距M=1.2MBwK(KN·m/m)
209.56
钢筋直径d (mm)
20
截面抵抗矩系数αS=M/α1fcbh02
0.1268
钢筋间距s (mm)
100
γS=(1+(1-2αS)1/2)/2
水池墙
跨中钢筋 钢筋直径(mm) 钢筋间距(mm) 钢筋实际面积(mm2) 配筋率ρ (%)
12 100 1130.40 0.51 满足
γ s=(1+(1-2α S) )/2 钢筋面积As(mm2)
0.01 M/α 1fcbh02 0.99 (1+(1-2α S)1/2)/2 172.86 M/γ sfyh0
2
地下室侧壁计算(裂缝挠度) 五、裂缝验算 活载准永久值系数ψ q 构件受力特征系数α cr 钢筋粘结特征系数ν 最大裂缝限值ω lim(mm) 0.5 1.9 1.0 0.3 2、支座裂缝验算 短期弯矩Ms(kN*m) 长期弯矩Ml(kN*m) ρ te=As/0.5bh ρ te实际取值(ρ te≥0.01) σ sk=Ms/0.87h0As (N/mm ) 纵筋等效直径deq=d/ν (mm) ψ =1.1-0.65ftk/ρ teσ sk ψ 实际取值(0.2≤ψ ≤1.0) 钢筋外边缘至受拉底边距离c(mm) ω max(mm) 3、跨中裂缝验算 短期弯矩Ms(kN*m) 长期弯矩Ml(kN*m) ρ te=As/0.5bh ρ te实际取值(ρ te≥0.01) σ sk=Ms/0.87h0As (N/mm2) 纵筋等效直径deq=d/ν (mm) ψ =1.1-0.65ftk/ρ teσ sk ψ 实际取值(0.2≤ψ ≤1.0) 钢筋外边缘至受拉底边距离c(mm) ω max(mm)
2
1、荷载标准值 恒载 三角形荷载Qak(kN/m) 均布荷载Qbk(kN/m) 活载 均布荷载Q3k(kN/m) 36.00 0.00 5.00
46.01 41.26 0.0075 0.01 280.71 12.00 0.59 0.59 20.0 0.20 满足 21.66 18.99 0.0090 0.01 100.13 12.00 -0.13 0.20 20.0 0.02 满足
水池配筋计算程序
三、裂缝验算
短期弯矩MS (KN· m) ρ te=AS/0.5bh 71.00 0.0084 长期弯矩Ml (KN· m) ρ te实际取值(ρ te≥0.01) 36.00 0.0100 2 受拉区纵筋等效直径deq=d/ν (mm) 28.6 84.71 σ sk=MS/η h0AS (N/mm ) ψ =1.1-0.65ftk/ρ teσ sk -0.442 应变不均匀系数ψ 实际取值(0.2≤ψ ≤1.0) 0.200 最外层受拉钢筋外边缘至受拉底边距离c (20≤c≤65) (mm) 20 最大裂缝宽度ω max=α crψ σ sk/ES(1.9c+0.08deq/ρ te) (mm) 0.05 最大裂缝宽度限值ω lim (mm) 验算ω max ≤ ω lim 0.20 满足
三、截面配筋
设计弯距M (KN· m) 截面抵抗矩系数α S=M/α 1fcbh02 1/2 γ S=(1+(1-2α S) )/2 钢筋面积AS=M/γ Sfyh0 (mm2) 99.00 0.0327 0.9834 729.5 钢筋直径d (mm) 钢筋间距s (mm) 2 钢筋实际配筋面积AS (mm ) 是否满足 20 150 2094.4 满足
一、原始数据
板厚h (mm) 板长l (mm) 混凝土强度等级 500 7000 C30 受力钢筋强度设计值fy (N/mm2) 钢筋弹性模量ES (N/mm2) 构件受力特征系数α cr 纵向受拉钢筋表面特征系数ν 300 2.0E+05 2.1 0.7
钢筋混凝土水池钢筋含量
钢筋混凝土水池钢筋含量
【原创实用版】
目录
1.钢筋混凝土水池的钢筋含量计算方法
2.钢筋混凝土水池的钢筋含量参考表
3.影响钢筋混凝土水池钢筋含量的因素
4.结论
正文
钢筋混凝土水池的钢筋含量计算方法:
在混凝土结构中,钢筋的含量对于整个结构的强度和稳定性至关重要。
计算钢筋混凝土水池的钢筋含量需要考虑许多因素,如结构尺寸、配筋率和钢筋的种类等。
一般来说,有图纸的话可以根据配筋率、结构尺寸来计算钢筋含量。
手工计算的方法是先认真看好水池的结构图,分清钢筋排号,从主筋开始,而后负筋、箍筋等,一项项算下去。
钢筋混凝土水池的钢筋含量参考表:
每 10 立方钢筋混凝土,钢筋含量参考表如下:
- 5 以内:100-150 公斤
- 5-10 以内:150-200 公斤
- 10-15 以内:200-250 公斤
- 15-20 以内:250-300 公斤
- 20-25 以内:300-350 公斤
- 25-30 以内:350-400 公斤
影响钢筋混凝土水池钢筋含量的因素:
影响钢筋混凝土水池钢筋含量的主要因素包括结构尺寸、配筋率和钢筋的种类。
结构尺寸越大,所需的钢筋含量也越多。
配筋率是指钢筋的面积与混凝土的面积之比,它决定了钢筋的密度。
钢筋的种类也会影响钢筋含量,不同类型的钢筋具有不同的强度和刚度,因此需要根据实际情况选择合适的钢筋。
结论:
钢筋混凝土水池的钢筋含量是一个复杂的问题,需要考虑许多因素。
一般来说,可以通过计算配筋率和结构尺寸来估算钢筋含量。
水池配筋计算
执行规范:《混凝土结构设计规范》(GB 50010-2002), 本文简称《混凝土规范》《建筑地基基础设计规范》(GB 50007-2002), 本文简称《地基规范》《给水排水工程构筑物结构设计规范》(GB50069-2002), 本文简称《给排水结构规范》《给水排水工程钢筋混凝土水池结构设计规程》(CECS138-2002), 本文简称《水池结构规程》-----------------------------------------------------------------------1 基本资料1.1 几何信息水池类型: 无顶盖半地上长度L=18.300m, 宽度B=8.500m, 高度H=3.850m, 底板底标高=-3.800m池底厚h3=350mm, 池壁厚t1=350mm,底板外挑长度t2=400mm注:地面标高为±0.000。
(平面图) (剖面图)1.2 土水信息土天然重度18.00 kN/m3 , 土饱和重度20.00kN/m3, 土内摩擦角20度修正后的地基承载力特征值fa=100.00kPa地下水位标高-1.500m,池内水深3.500m, 池内水重度10.00kN/m3,浮托力折减系数1.00, 抗浮安全系数Kf=1.051.3 荷载信息活荷载: 地面15.00kN/m2, 组合值系数0.90恒荷载分项系数: 水池自重1.20, 其它1.27活荷载分项系数: 地下水压1.27, 其它1.27活荷载准永久值系数: 顶板0.40, 地面0.40, 地下水1.00, 温湿度1.00考虑温湿度作用: 池内外温差10.0度, 弯矩折减系数0.65, 砼线膨胀系数1.00(10-5/°C) 1.4 钢筋砼信息混凝土: 等级C30, 重度25.00kN/m3, 泊松比0.20保护层厚度(mm): 池壁(内30,外30), 底板(上30,下30)钢筋级别: HRB335, 裂缝宽度限值: 0.20mm, 配筋调整系数: 1.00按裂缝控制配筋计算构造配筋采用混凝土规范GB50010-20022 计算内容(1) 地基承载力验算(2) 抗浮验算(3) 荷载计算(4) 内力(考虑温度作用)计算(5) 配筋计算(6) 裂缝验算(7) 混凝土工程量计算3 计算过程及结果单位说明: 弯矩:kN.m/m 钢筋面积:mm2裂缝宽度:mm计算说明:双向板计算按查表恒荷载:水池结构自重,土的竖向及侧向压力,内部盛水压力.活荷载:顶板活荷载,地面活荷载,地下水压力,温湿度变化作用.裂缝宽度计算按长期效应的准永久组合.3.1 地基承载力验算3.1.1 基底压力计算(1)水池自重Gc计算池壁自重G2=1598.62kN底板自重G3=1554.26kN水池结构自重Gc=G2+G3=3152.89 kN(2)池内水重Gw计算池内水重Gw=4804.80 kN(3)覆土重量计算池顶覆土重量Gt1= 0 kN池顶地下水重量Gs1= 0 kN底板外挑覆土重量Gt2= 1026.72 kN底板外挑地下水重量Gs2= 430.56 kN基底以上的覆盖土总重量Gt = Gt1 + Gt2 = 1026.72 kN基底以上的地下水总重量Gs = Gs1 + Gs2 = 430.56 kN(4)活荷载作用Gh地面活荷载作用力Gh2= 331.20 kN活荷载作用力总和Gh=Gh2=331.20 kN(5)基底压力Pk基底面积: A=(L+2×t2)×(B+2×t2)=19.100×9.300 = 177.63 m2基底压强: Pk=(Gc+Gw+Gt+Gs+Gh)/A=(3152.89+4804.80+1026.72+430.56+331.20)/177.630= 54.87 kN/m2 3.1.2 结论: Pk=54.87 < fa=100.00 kPa, 地基承载力满足要求。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
4100 2300 0.00 2760 0.00 3220 0.00 3680 0.00 4140 0.00 4600 0.00
160.00
162.23
140.00
均部范围c(mm) 100 均部中点距固定端距离b(mm) 920 0.00 1380 0.00 1840 0.00
400 4300 2300 0.00 2760 0.00 3220 0.00 3680 0.00 4140 0.00 4600 0.00
Mx (KN·m)
120.00
118.26
100.00
80.00
83.06
均部范围c(mm) 100 均部中点距固定端距离b(mm) 920 0.00 1380 0.00 1840 0.00
400 4300 2300 0.00 2760 0.00 3220 0.00 3680 0.00 4140 0.00 4600 0.00
500 920 0.00
距固定端距离b(mm) 1380 0.00 1840 0.00
41060 0.00
3220 0.00
3680 0.00
4140 0.00
4600 0.00
180.00
500 920 0.00
距固定端距离b(mm) 1380 0.00 1840 0.00
4600 1533 2300 20.28 2760 35.04 3220 55.64 3680 83.06 4140 118.26 4600 162.23
20.00
20.28
0.00 0
0.00 0.16 1.30 1000
4.38 3000 x (mm) 4000 5000
2000
400 4233 2300 0.00 20.28 2760 0.00 35.04 3220 0.00 55.64 3680 0.00 83.06 4140 0.00 118.26 4600 0.00 162.23
一、截面信息 板长l(mm)
4600
二、一个集中力P P(KN) 距悬臂端距离a(mm) 0 固定端支座反力RB=P (KN) 0 0 460 距悬臂端距离 x (mm) 弯距Mx(KN· m) 0.00 0.00 二、一个集中力P P(KN) 距悬臂端距离a(mm) 0 固定端支座反力RB=P (KN) 0 0 460 距悬臂端距离 x (mm) 弯距Mx(KN· m) 0.00 0.00 三、一段均部荷载q q (KN/m) 距悬臂端距离d(mm) 0 均部中点距悬臂端距离a(mm) 300 固定端支座反力RB=qc (KN) 0 0 460 距左端距离 x (mm) 弯距Mx(KN· m) 0.00 0.00 三、一段均部荷载q q (KN/m) 距悬臂端距离d(mm) 0 均部中点距悬臂端距离a(mm) 300 固定端支座反力RB=qc (KN) 0 0 460 距左端距离 x (mm) 弯距Mx(KN· m) 0.00 0.00
60.00 55.64
40.00 35.04
四、一段三角形荷载q (q 靠近固定端) q (KN/m) 距悬臂端距离d(mm) 三角形范围c(mm) 46 0 三角形形心距悬臂端距离a(mm) 三角形形心距固定端距离b(mm) 3067 固定端支座反力RB=qc/2 (KN) 105.8 0 460 920 1380 1840 距左端距离 x (mm) 弯距Mx(KN· m) 0.00 0.16 1.30 4.38 10.38 四、一段三角形荷载q (q 靠近固定端) q (KN/m) 距悬臂端距离d(mm) 三角形范围c(mm) 0 100 三角形形心距悬臂端距离a(mm) 三角形形心距固定端距离b(mm) 367 固定端支座反力RB=qc/2 (KN) 0 0 460 920 1380 1840 距左端距离 x (mm) 弯距Mx(KN· m) 0.00 0.00 0.00 0.00 0.00 叠加弯距Mx(KN· m) 0.00 0.16 1.30 4.38 10.38