铬镍奥氏体不锈钢焊缝铁素体测试程序Ferrite Testing Procedure,中英对照

合集下载
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

铬镍奥氏体不锈钢焊缝铁素体测试程序Ferrite Testing Procedure

目录

1适用范围Service scope (3)

2引用标准Reference (3)

3一般要求General requirements (3)

4试验准备Treating preparation (4)

5试验Testing (4)

6数据分析Data analyzing (6)

7记录Record (6)

1适用范围Service scope

1.1本程序适于xx罐区工程的铬镍奥氏体不锈钢焊缝的测量。

This procedure is applicable for the measurement of ferrite composition in Cr-Ni austenite stainless steel welding of xx tank area project.

1.2测试范围:对于同一种规格的管口焊缝和同一种规格板厚对接焊缝,在其焊缝上测3点。

Testing scope: pipe joints with the same specification of base material and the same thickness of plate joints shall take 3 test points on the welding seam.

2引用标准Reference

GB1954-80《铬镍奥氏体不锈钢焊缝铁素体含量测量方法》

GB1954-80《Measuring Method for Ferrite Composition in Cr-Ni Austenite Stainless Steel Welding》

PMC焊接和NDE一览表167

Welding & NDE Matrix-Form167 of PMC

3一般要求General requirements

3.1设备要求Requirements for testing equipments

3.2试样要求Requirements for testing piece.

试样的试验面应清洁,不得有氧化皮及其他污物。

The surface of testing piece should be clean, no oxide skin or other filth.

3.3环境要求Environmental requirements

试验一般在-20-50℃温度范围内进行,现场环境无强烈震动和摆动。

Temperature range should be –20-50℃, mo strong shakes or swings on testing site.

3.4人员Personnel

3.4.1试验员职责:检验前调试并保证设备处于良好状态,数据分

析并填写记录。

Test personnel responsibility: Before inspection, adjusting and ensuring the equipment in a good state. Analyses data and fill in the record.

3.4.2理化工程师:负责数据分析和报告的审核。

Physical and chemical engineer: Be responsible for the audit of data analysis and report.

4试验准备Treating preparation

检查铁素体测定仪电量是否充足。

Check the battery in ferrite meter.

5试验Testing

5.1检测前先用标准试块对铁素体测定仪进行校验,检查其精度是否符合要求。

Calibrate ferrite meter with standard test block before testing, check whether the accuracy can meet requirements.

5.2在开机之前调整相应的螺钉,检查和调整测定仪的机械零点,将

操作选择开关转到“Batt”位置,检查电池的连接情况,指钉应到达或在表盘的绿色区域内。

Before turn on the meter, adjust the related bolts, check and adjust the mechanical zero of ferrite meter, turn, check the battery connection, the pointer should be reached or in green area on dial plate.

5.3在调节电零点时,操作选择开关需转到“Messen Open”,同时范

围开关调到“O”位置,可以用机器的左边开关上边的电位器,校正零点。电零点的调整必须与机械零点的调整相对应。

Turn operating option switch to “Messen Open”when adjusting electrical zero, and span switch to “O” at the same time, then adjust zero with potentiometer which is at the top of left switch. The adjusting of electrical zero must be corresponding to adjusting of mechanical zero.

5.4操作选择开关调到“MESSEN”位置,范围开关放在“1%FG”位

置,触头置于环境中,通过粗选和精选补偿开关调整仪器指针到零点。

Turn operating option switch to “MESSEN” span switch to “1%FG”, the contact finger of detector in atmosphere, and adjust the meter pointer to zero point by coarse and fine switch.

5.5范围开关放在“12%FG”位置,同时探头垂直放在仪器盖内的校

准试样的中心,通过开关可以调整指针所示的标准试样给定的值。

Turn span switch to “12%FG”, and also vertically place the detector at the center of standard sample which is in the cover of instrument, and the set-point of standard sample which is displayed by pointer can be adjusted by switch.

5.6在测量前根据材料的性能,适当的选择铁素体含量的测量范围,

同时需要看“零”点是否准确。

Before testing, select proper measurement range of ferrite composition according to the material performance, and view whether the zero point is correct.

5.7各项准备工作完备后,在开机15分钟后用于正式测量。

If the preparation is finished, turn on the meter, and begin to test in 15 minutes.

5.8将铁素体测定仪的探头垂直放置于所测试样上,待指针稳定后读

取度盘上所显示的值。探头式仪器在任何情况下进行测量时,均需保证探头的触头与被测面之间的点接触。