地下人防工程施工方案57411

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

目录

1.编制依据························································错误!未指定书签。

2.工程概况························································错误!未指定书签。

3.施工准备························································错误!未指定书签。

3.1施工现场准备···················································错误!未指定书签。

3.2施工流水段划分原则·············································错误!未指定书签。

3.3施工流程·······················································错误!未指定书签。

4.技术准备························································错误!未指定书签。

5.材料准备························································错误!未指定书签。

5.1钢筋原材·······················································错误!未指定书签。

5.2模板架料·······················································错误!未指定书签。

5.3混凝土·························································错误!未指定书签。

6.机具准备和劳动力安排·············································错误!未指定书签。

6.1机具准备(人防部分)···········································错误!未指定书签。

6.2劳动力安排(人防部分)·········································错误!未指定书签。

7.主要的施工方法和技术措施·········································错误!未指定书签。

7.1钢筋工程·······················································错误!未指定书签。

7.2模板工程·······················································错误!未指定书签。

7.3混凝土工程·····················································错误!未指定书签。

8.质量保证措施····················································错误!未指定书签。

8.1钢筋工程质量控制···············································错误!未指定书签。

8.2模板工程质量控制···············································错误!未指定书签。

8.3混凝土施工质量控制措施·········································错误!未指定书签。

9.成品保护措施····················································错误!未指定书签。

10.安全生产与文明施工措施错误!未指定书签。

1.编制依据

施工合同文本

施工设计图纸及洽商变更

《混凝土结构施工图平面整体表示方法制图规则和构造详图筏形基础》11G101-3

《混凝土结构施工图平面整体表示方法制图规则和构造详图》11G101-1

《建筑设计防火规范》GB50016-2006

《高层民用建筑设计防火规范》GB50045-95(2005版)

《汽车库、修车库、停车场设计防火规范》GB50067-97

《汽车库建筑设计规范》JGJ100-98

《建筑内部装修设计防火规范》GB50222-95

《建筑灭火器配置设计规范》GB50140-2005

《人民防空地下室设计规范》GB50038-2005

《人民防空工程设计防火规范》GB50098-98

《建筑地基基础工程施工质量验收规范》GB50202-2002

《混凝土结构工程施工及验收规范》GB50204-2010

《建筑工程抗震设防分类标准》GB50223-2004

《普通混凝土配合比设计规程》JGJ55-2000

《钢筋机械连接通用技术规程》JGJ107-2010

《地下工程防水设计规范》GB50108-2008

《防空地下室结构设计》07FG01~05

《防空地下室建筑设计》FJ01~03

《人民防空地下室设计规范》05SFJ10

2.工程概况

1、本工程位于合肥市双凤开发区蒙城北路与金兰路交口。人防掩蔽所面积为

8337.68m2。本工程地下一层防护等级为甲类核六级防化等级为丙级。平时功能为地下停车库,战时为二等功能掩蔽所;共分为四个防护单元,16个抗暴单元,12个人防口部,掩蔽人生4265人。

2、防水设计

本工程为II级防水,两道防水设防,顶板、配电室、机房等设备用房防水等级为I级,三道防水设防。人防地下室采用砼结构自防水,并附加迎水面附加防水层,抗渗设计等级为P6。后浇带部位采用防水卷材加强处理,在后浇带中部设置钢板止水带。

3、临战转换设计

人防地下室战时使用的干厕、水箱、机房、口部等设施在临战前完成。平时使用的风管、消防水管、孔洞、地沟等在临战时拆除后用砼或预制砼板封堵。

临战封堵的孔洞、密闭隔墙,抗暴挡墙等周边结构砼要预埋钢板。临战封堵高均小于3m,长不超过6m,抗暴单元隔墙临战时采用沙袋堆砌,其厚度不应小于500mm,高度不应小于1800mm,界面为梯形,战时值班室等房间临战时采用煤矸石空心砖200厚、人防门编号均按RFJ01-2008图集说明编号,其门槛级门框墙施工以结构图为准。

4、结构工程

(1)、本工程为单建式人防地下室、钢筋砼结构,基础采用柱下钢筋砼独立基础。基础设计等级为丙级。

(2)人防地下室抗力等级为核6级,防水等级二级,地下室抗震等级为四级。

(3)人防地下室外墙战时其外侧覆土厚度不得小于10m或外墙顶标高低于室外地面。