GERMANY
HOME BOOSTER
OWNER’S MANUAL
MODEL
PB-088EA
PB-168EA
PB-H089EA
PB-H169EA
READ OVER THIS OWNER’S MANUAL BEFORE THE FIRST OPERATION OF YOUR PUMP FOR THE SAKE OF ITS OPTIMUM EFFICIENCY.
1. PRECAUTION BEFORE USING THE PUMP
2. APPEARANCE AND NAME OF THE PARTS
OUTLET
FLOW SWITCH TERMINAL BOX
MOTOR POWER CORD
TERMINAL BOX
OUTLET TERMINAL BOX
MOTOR
OUTLET
(The shape of the plug varies according to countries.)
CASING
INLET
POWER CORD FLOW SWITCH TERMINAL BOX MOTOR
COVER OUTLET
CASING
SUPPORTER 1Piece
3. CAUTION FOR INSTALLATION above 20cm(7.9)
above 3cm(1.2)
4. SPECIFICATION
MODEL
OUTPUT POWER SOURCE POWER FREQUENCY TOTAL HEAD CAPACITY PIPE DIMENSION TEMPERATURE
90W(0.12Hp)
60W 220V 50Hz Max. 35/min(9.2Gal/min)
15mm (1/2)0~60C
0~100C
PB-088EA PB-H089EA PB-168EA PB-H169EA
Max. 9m(29.5Ft)290W(0.4Hp)
160W 220V 50Hz Max. 45/min(11.9Gal/min)
15mm (1/2)0~60C
0~100C
Max. 15m(49.2Ft)1. Definition of horizontal or vertical installation.
2. You need to change the pump as follows for vertical installation (We sell this pump on the basis of horizontal installation)
1) Disassemble the flow switch part from the casing by disassembling 2 bolts.2) Rotate the pump and assemble the flow switch part as the flow switch cover faces up ward.Valve Assy in flow switch part is operated by the gravity, so the flow switch part must be installed as the flow switch cover faces upward.
FLOW SWITCH COVER FLOW SWITCH BOLT (M614,2 Pieces)
FLOW SWITCH COVER FLOW SWITCH
BOLT (M614,2 Pieces)SUPPORTER (Rubber)
6. WIRING DIAGRAM
5. PERFORMANCE CURVE
Motor
Capacitor
1, 220V/50Hz
9/450VAC
Reed Switch
Rocker Switch
Power Source PCB Plate
Motor
PB-168EA/H169EA
Capacitor
T o t a l H e a d
Capacity
7. DIMENSION (unit;mm )
8. GUIDE FOR INSTALLATION
Min.
2/min(0.5Gal/min)If it was below
2/min(0.5Gal/min),you should use manually.
in case of converting mm into inch 1mm=0.0394
inch, ex)214mm=8.43inch
9. TROUBLES AND COUNTER-MEASURES
Fault
Cause
Selector in Off (pos. ).
Flow rate too low to activate flow
switch the flow rate must be higher than 2/min(0.5Gal/min)Supply failure.
Impurities in the flow switch.(PB-088EA, PB-H089EA)Main valve closed.
Air in the system.Air drawn into s/pipe.
Impurities in the pump.
Air in the system/pump.Selector in Manual(pos. = ).
Impurities in the flow switch.(PB-088EA, PB-H089EA)
Remedy
Turn selector to Auto (pos. )
or Manual (pos. = ).
Turn selector to Manual (pos. = ).
Check fuses and possible loose electrical connections.Remove Motor Assy, flow switch cover and clean the part, see page 7.Open main valve.
Leave the pump running or a few minutes with tap turned on.
Dismantle and clean the pump.
Leave the pump running for a few minutes with tap turned on.
Turn selector to Off (pos. ) or Auto (pos. ).
Remove Motor Assy, flow switch cover and clean the parts, see page 7.
Pump does not start.
Pump is running,
but does not
produce any pressure.
Noise in pump.
Pump does not
stop when tap is turned off.
P/NO. : 3828KP0047M (Rev.2)。