SGF系列双筒高压过滤器(新型)
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
SGF
SGF DUPLEX HIGH PRESSURE LINE FILTER SERIES
() MODEL CODE
TECHNICAL DATA
With CMS indicator Omit if without indicator Flanged connection Filtration connection:(m) Flow rate(L/min)
P1
P2
PLFX-30*LH0060D*BN3HC LH0110D*BN3HC LH0160D*BN3HC LH0240D*BN3HC LH0330D*BN3HC LH0500D*BN3HC LH0660D*BN3HC
1224
36220
2.52
1.50.25
Flange
()
V ()A Indicator Weight (Kg)
Connect
Model of element *32MPa 160L/min 10m SGF BH-H16010C LH0160D010BN3HC
Note:*is represents filtration. If the filter fluid is water-glycol, usage pressure 32MPa flower rate 160L/min filtration accuracy 10m and the filter equipped with indica-
tor. The model of the filter is SGF BH-H160
10C, the model of element is LH0160D010BN3HC
0.5MPa
INTRODUCTION
The SGF series filter is composed of two single bowl filters, check valve, di-rectional valve and indicator. It should be installed at outlet of the high-pressu-re line. The feature of this filter allows continuous operation even during repla-cing element, which is clogged by contaminant. When the pressure of the cont-aminant clogged element reaches to 0.5Mpa, the indicator gives signals showi-ng that the element should be changed. At this time, turn the directional valve, let the other filter work, and change the clogged element. If the element can't be changed in time until the pressure reaches to 0.6Mpa, the by-pass valve will open automatically to keep the system safety.
() MOUNTING SIZE