INPUT

输入lumen

watt

Ballast/gear needed

OUTPUT Read the intermediate steps and the Energy Efficiency Index in the blue cells Steps

1.Reference power (P ref )

If Φuse < 1300 lumen : P ref = 0.88√Φuse +0.049Φuse

If Φuse ≥ 1300 lumen : P ref = 0.07341Φuse

25.49watt

2.Power Correction Factor for external control gear (according to Table 2)

1

3.Corrected Power (P cor )

P cor = P rated x Power Correction Factor

3.4watt

4.Energy Efficiency Index (EEI)

EEI = P cor / P ref

0.13

5.

Energy Class A+241.23.4none Calculation method according to the new lamp energy labelling regulation 874/2012/EC