ERP能效标准计算

合集下载
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

INPUT

输入lumen

watt

Ballast/gear needed

OUTPUT Read the intermediate steps and the Energy Efficiency Index in the blue cells Steps

1.Reference power (P ref )

If Φuse < 1300 lumen : P ref = 0.88√Φuse +0.049Φuse

If Φuse ≥ 1300 lumen : P ref = 0.07341Φuse

25.49watt

2.Power Correction Factor for external control gear (according to Table 2)

1

3.Corrected Power (P cor )

P cor = P rated x Power Correction Factor

3.4watt

4.Energy Efficiency Index (EEI)

EEI = P cor / P ref

0.13

5.

Energy Class A+241.23.4none Calculation method according to the new lamp energy labelling regulation 874/2012/EC

依据2012/874/EC 的能效计算方法

Insert the data or select the type information about the examined lamp in the yellow cells 黄色表格内填入数据或选择产品对应信息

Useful luminous flux (Φuse , according to Table 3)

select "none" if no such gear, "halo" for halogen gear, "LED" for LED gear, "fluo-T5" for T5or 4-pin single capped fluorescent ballast, "fluo-other" for other fluorescent ballast,"HID" for HID ballast,"sodi" for low pressure sodium lamp ballast,

Lamp Category

Rated Power (P rated )

External control gear

Non-Directional Lamp

相关文档
最新文档