SWAN在线式浊度仪手册

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

support@swan.ch
Document Status Sheet
Title:
Monitor AMI Turbitrack Operator’s Manual
ID:
A-96.250.231
Revision Issue
00
June 2005
© 2005, SWAN ANALYTISCHE INSTRUMENTE AG, Switzerland, all rights reserved Information contained in this document is subject to change without notice.
2. Product Description
2.1 Instrument Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.2 Instrument Specification. . . . . . . . . . . . . . . . . . . . . . . . . . 6
A-96.250.231 / 050607
I
AMI Turbitrack
Table of Contents
Table of Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I
1. Safety Instructions
2.4.2 Menu Navigation Keys . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.4.3 Software Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.4 Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.4.1 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.2.3 Turbidimeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9
2.3 Description of the System . . . . . . . . . . . . . . . . . . . . . . . . 10
5. Operation
5.1 Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 5.2 Signal Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 5.3 Relay Contacts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 5.3.1 Alarm Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 5.3.2 Relay 1 and Relay 2. . . . . . . . . . . . . . . . . . . . . . . . . . . 28 5.3.3 Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 5.4 Logger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
AMI Turbitrack
Preface
Preface
The Operator’s Manual provides thorough information about the installation, operation and maintenance of the instrument for the user and service technician.
1.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Warning Notices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.3 General Safety Regulations . . . . . . . . . . . . . . . . . . . . . . . 3 1.3.1 Legal Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.3.2 General Inspection and Maintenance Duties . . . . . . . . 3 1.3.3 Spare Parts and Disposables. . . . . . . . . . . . . . . . . . . . 3 1.3.4 Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.3.5 Electrical shock hazard . . . . . . . . . . . . . . . . . . . . . . . . 4
To be qualified for operating the instrument, you must … read and understand the instructions in this manual; have appropriate operator’s training; know the relevant safety rules and regulations.
II
A-96.250.231 / 050607
AMI Turbitrack
Table of Contents
3. Installation
3.1 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.2 Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.2.1 Scheme AMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.2.2 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 3.3 Relay Contacts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.3.1 Alarm Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.3.2 Relay Contacts 1 and 2 . . . . . . . . . . . . . . . . . . . . . . . . 20 3.4 Signal Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 3.4.1 Signal Outputs1 and 2 (current outputs) . . . . . . . . . . . 21 3.4.2 Signal Output 3 (optional) . . . . . . . . . . . . . . . . . . . . . . 21 3.5 Interface RS485 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 3.6 Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 3.6.1 Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Qualification, Training
To be qualified for instrument installation, you must … have appropriate professional service training; read and understand the instructions in this manual.
4. Instrument Setup
4.1 Preparatory Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 4.2 Establish Sample Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . 24 4.3 Regulating the Sample Flow . . . . . . . . . . . . . . . . . . . . . . 25 4.4 Set Default Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
2.2.1 Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2.2 Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Monitor AMI Turbitrack
Version 2.20 and later
Operator’s Manual
SWAN sets the standard
A-96.250.231 / 050607
wenku.baidu.com
Customer Support SWAN and its representatives maintain a fully trained staff of technical specialists around the world. For any technical question, contact your nearest SWAN representative, or the manufacturer:
SWAN ANALYTISCHE INSTRUMENTE AG Turicaphonstrasse CH-8616 Riedikon/Uster
Phone Telefax Internet
+41 1 943 63 00 +41 1 943 63 31 www.swan.ch
Hotline
E-mail
相关文档