2磷酸盐在线分析仪
正磷酸盐在线分析仪技术参数
Phosphaxsc正磷酸盐分析仪1)SC200控制器2)PhosphaxSC仪器特点・测量量程宽・检测限宽,适合于多种污水处理的应用场合・运行成本低,分析方法可靠・控制营养盐去除工艺时,响应迅速・在测量点容易安装・维护率低・即插即用型的数字控制器技术指标测量方法:光度计比色法(帆铝黄法)量程:量程1:0.05-15.Omg/LPO-P量程2:1.00-50.0mg/LPO-P最低检测限:量程L0.05mg/LPO-P量程2:1.OOmg/LPO-P准确度:量程1:2%或0.05mg/L取较大值量程2:2%或1.0mg/L取较大值试剂消耗:量程L每4个月需要消耗2000mL量程2:每2个月需要消耗2000mL响应时间(T90):5min.包括样品预制备测量间隔:5-120min.可调特点:自清洗,自动的零点校准,全面的自诊断。
可为连续的样品流选配双通道型号环境温度:-20℃〜+45℃水样温度:+4℃〜+40℃安装:户外-(IP55)和室内一壁挂式安装、栏杆式安装和立式安装尺寸:(W×H×D)540×720X390nun电源:115V∕50-60Hz或230V∕50Hz,连接到SCIOoo控制器重量:35kg,含试剂sc200技术参数:显示:图形数据点阵LCD,带LED背景灯照明,半透明反射式;在任意光线下可读;显示屏分辨率:160X240像素;显示屏尺寸:48X68mm(1.89x2.67");安全等级:两个密码保护;探头输入:单通道;模拟和数字传感器任意搭配和组合使用;输出:两路模拟的0/4-2OmA输出信号,带独立的PID控制功能工作环境:-20~60°C,0〜95%相对湿度、无冷凝;存储环境:-20^70o C,0〜95%相对湿度、无冷凝;继电器:四个SPDT(C型)触头,1200W,5A,250Vac;外壳防护等级:NEMA4X/IP66;电源:100、240VAC±10%,50∕60Hz;电子认证:EMC:CE认证,电磁和辐射排放符合EN50081-2, 抗干扰符合EN61000-6-2;安装方式:壁挂/面板/夹管式安装;外壳材质:聚碳酸酯,铝质(镀粉末),不锈钢;控制器尺寸:144X144X181mm;控制器重量:1.70kg(3.75lb)O。
总磷水质在线分析仪示值误差的不确定度评定和检定注意事项
电子质量2020年第06期(总第399期)作者简介院许雪琼(1986-),女,河南郑州,助理工程师,学士,主要从事环境保护设备计量工作。
总磷水质在线分析仪示值误差的不确定度评定和检定注意事项The Evaluation of Uncertainty of Indication Error in Total Phosphorus Water Quality on-lineMonitor and Notes for Verification许雪琼,闫继伟,马振奇,路兴杰(河南省计量科学研究院,河南郑州450003)Xu Xue-qiong,Yan Ji-wei,Ma Zhen-qi,Lu Xing-jie (Henan Institute of Metrology,Henan Zhengzhou 450003)摘要:文章以聚光科技生产的TPN-2000(TP)总磷水质在线分析仪为例,对影响其测量结果扩展不确定度的各个分量进行分析,并依据JJG1094-2013《总磷总氮水质在线分析仪检定规程》的要求分段给出示值误差的扩展不确定度,以期为排污收税、环境执法、总量减排等提供计量数据支撑。
关键词:总磷;示值误差;扩展不确定度中图分类号:X832文献标识码:A文章编号:1003-0107(2020)06-0038-05Abstract:Taking the TPN-2000(TP)total phosphorus water quality on-line analyzer produced by JuGuang technology as an example,This paper analyze the each components that affect the extended uncertainty of measurement results,and According to JJG1094-2013"water quality online analyzers of total phosphorus and total nitrogen",the extended uncertainty of indication error is presented in sections,so as to provide measurement data support for pollution tax,environmental law enforcement,total emission reduction and so on.Key words:Total phosphorus;Indication error;Extended uncertainty CLC number:X853Document code:AArticle ID :1003-0107(2020)06-0038-050引言在天然水和废水中,磷几乎都以各种磷酸盐的形式存在,它们分为正磷酸盐,缩合磷酸盐(焦磷酸盐、偏磷酸盐和多磷酸盐)和有机结合的磷(如磷脂等),主要存在于溶液中、腐殖质粒子中或水生生物中。
磷酸根分析仪的使用操作规定模板
磷酸根分析仪的使用操作规定模板1. 介绍本规定适用于公司内部使用的磷酸根分析仪。
为了确保磷酸根分析仪的正确操作和有效使用,减少人为操作错误及设备损坏,保证生产过程的安全和质量,订立本规定。
2. 磷酸根分析仪的功能和操作原理磷酸根分析仪是一种用于定量分析磷酸盐的仪器。
它通过光学测量或电化学测量的方法,测定样品中磷酸盐的浓度。
实在操作原理和使用方法请参考磷酸根分析仪的操作说明书。
3. 使用前的准备工作•确保磷酸根分析仪在良好的工作状态下,没有任何异常。
•检查仪器的电源及各部件的连接是否正常。
•确保所使用的试剂和标准溶液均符合质量要求,并在有效期内。
•全部操作人员应具备相应的操作技能和必需的安全意识。
4. 操作步骤及注意事项4.1 样品制备•样品的准备要依据实在的试验要求进行,确保样品的稳定性和充分代表性。
•样品应避开长时间暴露在空气中,避开氧化和污染。
•样品的储存应在规定条件下进行。
4.2 仪器的准备工作•检查仪器是否处于待机状态,如有其他人使用完毕,请将仪器调整到待机状态。
•确认必需的设备和试剂已经齐备。
•打开仪器电源并进行系统自检,确保仪器正常工作。
•清洗仪器的相关部件,并进行验证。
4.3 仪器的操作步骤1.将标准溶液和待测样品分别倒入样品池中,注意避开污染和交叉感染。
2.打开仪器的软件程序,选择正确的分析方法。
3.在软件程序中输入样品的相关信息,如样品编号、测量参数等。
4.点击开始测量,仪器会自动进行测量并记录结果。
5.测量完成后,关闭仪器并清洗相关部件。
4.4 注意事项•操作过程中要佩戴适当的防护手套、眼镜等个人防护装备。
•严禁将任何物体放入磷酸根分析仪的样品池中,以免损坏仪器和影响测量结果。
•操作结束后及时清洗仪器,保持仪器乾净干净。
•对于使用过程中显现的问题和异常情况,应及时向上级报告并寻求帮忙。
5. 管理标准和考核标准•管理标准:各部门负责磷酸根分析仪的管理和维护,定期进行设备巡检和维护记录。
Systea NPA 仪器简介NUTRIENTS PROBE ANALYZER
Systea NPA 仪器简介NUTRIENTS PROBE ANALYZERNPA-(NUTRIENTS PROBE ANALYZER,即原位营养盐多参数探头分析仪) NPA Plus 是用来在地表水或者海水里潜水式在线可同时分析多达四个营养盐参数的多参数仪。
特别的最新设计用于海岸监测浮标或者浮台短中期投放使用。
一套NPA系统,由三个部分组成:•锚系支架•试剂容器(请见第2页)•分析模块和电路(请见下面的介绍)其中,分析和电路部分的内部结构如下:A 多通路阀B 泵马达C 泵头D 供电E CPU和IO板F 显示接口板和外接键盘板G 试剂入口H 流通池附件I 光源和光纤附件L 混合和压力器M 外部(试剂)进口N 泵头连接处O 多通路阀和Teflon管道附件试剂篮被设计为野外可快速取下(如下图所示)和安上。
●6×200mL试剂袋、1L标样袋、1L水袋●废弃袋(5L,可选)收集有毒废弃物,无毒废弃物直接排放NPA的接口NPA的接口位于仪器的底部,如左图所示:A 电源和RS232接口B 有毒废液出口C 样品入口D 废液(无毒,仅用于冲洗)E 冲洗水入口F 压力测试接口(工厂测试用)NPA plus测量的结果用浓度单位表示。
测量值被存储时带有日期、时间和样品的空白值,同样的数值可通过串口远程传输,仪器容许彻底的远程控制。
所有分析程序和功能可通过运行标准的PC机使用NPA控制软件被添加到分析仪中。
每次分析每种试剂的消耗被减少到大约100μL。
.试剂被密封装入袋中并被周围的水体冷藏降温。
工厂也提供Peltier冷藏器的选项。
NPA采用的是Systea拥有的专利技术(LFA技术)。
上图中LED采用的光源128 660 nm129 525nm试剂与接口对应如下所示:NPA采用了被国际标准推荐使用的湿化学分析方法:•氨氮(NH3): 贝特洛反应法(Berthelot reaction)•磷酸盐(PO4): 磷钼蓝法(Molibdate, Ascorbic acid)•硝酸盐和亚硝酸盐(NO3+NO2)镉还原+ Griess反应(Cd reduction NED, SAA)•亚硝酸盐(NO2): Griess反应(NED, SAA.)分析循环的步骤●引入样品至反应器●测量样品空白和储存(空白光学密度)●按正确顺序与时间注射试剂●样品和试剂混合●如果需要,加热●反应时间●测量反应光学密度和储存(结束光学密度)●使用存储校准系数计算样品的浓度NPA可检测到如下痕量水平的检出限:•氨氮(Ammonia): 2 ppb•正磷酸盐(Orthophosphate): 1 ppb•硝酸盐和亚硝酸盐(Nitrate + Nitrite): 2 ppb•亚硝酸盐(Nitrite): 0.6 ppb.NPA 特别设计用于海洋研究和环境监测。
磷酸根分析仪的使用操作规定
磷酸根分析仪的使用操作规定一、磷酸根分析仪的概述磷酸根分析仪是一种用于测定水中磷酸盐含量的仪器,通常用于环境监测、水质检测等领域。
磷酸根分析仪测定磷酸盐含量的原理是:将水样与含有一定浓度的盐酸反应,生成磷酸氢二氢盐,加入铵钼酸铵溶液再加入还原剂,使得磷酸根在硝酸钴的催化下被还原为蓝色,最后通过分光光度计测定蓝色的吸光度,计算出磷酸盐含量。
二、使用操作规定1.准备工作(1)磷酸根分析仪的安装:将分析仪放在平稳的桌子上,按照说明书进行安装,连接好电源和电缆。
(2)质控样品的制备:制备好标准原液,可以购买商家提供的标准物质或自制。
(3)试剂的准备:从试剂瓶中取出必要的试剂,准备好不同浓度的标准溶液,放置在标准桶内备用。
2.样品处理(1)取样:用清洁水瓶取样,取样时应先用清水冲洗取样瓶,避免受旧水的污染,再将样品在空瓶中采集,重量或体积应根据样品的不同特性而定,尽量保持规范化。
(2)样品处理:将取样瓶中采集到的样品分销前进行充分搅拌均匀,以保证分析的准确性,根据不同的样品特性进行不同的样品处理,如过滤、降解等。
(3)样品保存:保存样品时,一定要保证其不受到外界的污染,尽可能减少样品的暴露时间,避免被水分解3.标准曲线的绘制(1)分别取不同浓度的磷酸盐标准溶液,按照分析仪器的使用说明进行稀释操作,制备出不同浓度的标准曲线样品。
(2)将制备好的标准曲线样品分别注入分光光度计中,进行测定并记录吸光度值。
(3)将测定得到的吸光度值按照标准曲线样品的浓度绘制成标准曲线,用于后续研究。
4.样品的测定(1)按照样品处理的要求,处理好样品后,充分均匀的摇动样品,取25mL样品加入至试剂桶内。
(2)注入盐酸制备出磷酸氢二氢盐,再加入铵钼酸铵溶液,经还原剂还原后加入硝酸钴进行催化。
最后加水至指示线。
(3)等待反应结束,取出分光光度计进行吸光度测定。
(4)根据磷酸根含量的标准曲线计算出样品的磷酸盐含量,并进行记录。
(4)及时清洗仪器:完成测定后,记得要将仪器各部分彻底清洗并擦干净,避免损坏。
在线分析仪表的分类
在线分析仪表的分类在线分析仪表是一种用于检测、分析、计量各种文气和非气体、液体和固体的仪表。
根据其应用和测量对象的不同,现代在线分析仪表被分为多种类型,下面将分别进行介绍。
硫化物分析仪硫化物分析仪是一种在线分析仪表,主要用于检测气体或流体中的硫化物浓度。
硫化物是造成环境问题的主要物质之一,包括硫化氢、二硫化碳、甲硫醇等。
硫化物分析仪可广泛地应用于冶金、化学、制药等领域和工业废水的排放监控。
气体分析仪气体分析仪是一种主要用于气体的分析检测的在线仪器。
气体分析仪的测量方法主要包括比色法、吸收光谱法、散射光谱法、拉曼光谱法、反射率法、热导法、电离法、气相色谱法等。
气体分析仪的应用领域广泛,如环境保护、化学品生产、钢铁、石油化工、电力等行业。
液体分析仪液体分析仪主要用于在线检测液体中的各种物质的浓度,包括测量水中的氨氮、氟化物、磷酸盐、COD等。
液体分析仪的原理包括颜色比色法、荧光光谱法、离子选择性电极分析法、电导率测量法等。
液体分析仪被广泛应用于环保、水处理、制药、食品、饮料等行业。
固体分析仪固体分析仪通常用于检测固体材料中的各种元素的成分和浓度,以及体积与表面量、粒度大小、分布范围等信息。
固体分析仪的测量方法包括X-射线荧光分析、原子吸收光谱、电化学分析等。
固体分析仪广泛应用于金属、非金属矿产、建筑材料、环保材料等的生产过程中,以便实现实时质量控制和优化生产。
水质分析仪水质分析仪主要用于测量水环境的各种参数,如水温、浑浊度、PH值、溶解氧、电导率、总磷等。
水质分析仪的应用十分广泛,可用于城市供水、污水处理、流域监测、农业、水产品养殖、游泳池监管等领域。
在线分析仪表的分类不止以上五种,其他像有机物分析仪、溶解氧分析仪等也都是在线分析仪表的代表。
通过在线分析仪表,可以实现对各种物质的实时监测与控制,提高生产效率,保护环境。
磷酸盐的检测方法
磷酸盐的检测方法
磷酸盐是一种常见的无机化合物,广泛存在于自然界中。
下面介绍两种磷酸盐的检测方法:
1. 钼酸铵分光光度法:这是一种常用的检测磷酸盐的方法。
在酸性条件下,磷酸盐与钼酸铵反应生成黄色的磷钼杂多酸,其吸光度与磷酸盐的浓度成正比。
通过测量吸光度,可以定量检测磷酸盐的含量。
该方法具有灵敏度高、准确性好等优点。
2. 离子色谱法:这是一种利用离子交换原理分离和检测磷酸盐的方法。
将待测样品注入离子色谱仪,经过离子交换柱的分离,磷酸盐与其他离子分离开来。
然后,通过检测器检测磷酸盐的浓度。
该方法具有快速、灵敏、准确等优点,适用于检测水中的磷酸盐。
需要注意的是,不同的检测方法适用于不同的样品类型和检测要求。
在选择检测方法时,需要根据实际情况进行选择。
同时,为了保证检测结果的准确性,需要严格按照操作规程进行操作,并对检测结果进行验证和校准。
以上是两种常见的磷酸盐检测方法,希望对你有所帮助。
如果你需要更详细的信息,建议查阅相关的专业书籍或咨询专业人士。
聚光TP-2000总磷在线分析仪用户手册-1.01
我公司客户服务部的联系方式是: 客服热线:4007 007 555 传真:0571-85012188-1540 E-MAIL:tech_support@ 网址:
声明
本用户手册对用户不承担法律责任,所有的法律条款请见相应的合同。 聚光科技(杭州)有限公司版权所有,如有改动,恕不另行通知;未经允许,不得翻印。
III
TP-2000 总磷在线分析仪 用户手册
FOCUSED PHOTONICS INC
警告:
1.本仪器安装及更换试剂时可能有危险,请务必遵守下列各条: z 穿上安全服(实验工作服); z 戴上安全眼罩/面罩; z 戴上橡胶手套。
2. 运行仪器不能用蒸馏水或饮料替代试剂,否则有可能导致消解反应器温 度过高,从而发生爆炸的危险!
FOCUSED PHOTONICS INC
TP-2000 总磷在线分析仪
用户手册
Focused Photonics Inc.
聚 光 科 技 (杭 州) 有 限 公 司
UMTP20000811100
TP-2000 总磷在线分析仪 用户手册
FOCUSED PHOTONICS INC
阅读说明
用户须知
非常感谢您选择使用本公司的 TP-2000 总磷在线分析仪(以下简称:TP-2000 分析仪)。 在使用本产品前,请您仔细阅读本用户手册。本手册涵盖产品使用的各项重要信息及数据, 用户必须严格遵守其规定,方可保证 TP-2000 分析仪的正常运行。同时,相关信息可帮助 用户正确使用该产品,并获得准确的分析结果。
3. 请严格按照当地环保监管部门或相关部门的废液处理回收规定方法处理 试剂废液,未经处理倾倒废液将污染环境!
IV
TP-2000 总磷在线分析仪 用户手册
磷酸盐的测定实验报告
一、实验目的1. 掌握磷钼蓝分光光度法测定磷酸盐的原理和操作步骤。
2. 熟悉分光光度计的使用方法。
3. 了解实验过程中可能出现的误差及其原因。
二、实验原理在强酸性条件下,磷酸盐与钼酸铵反应生成磷钼杂多酸,该杂多酸能被还原剂(如氯化亚锡)还原,生成蓝色的络合物——磷钼蓝。
蓝色深浅与磷酸盐含量成正比,通过比色法可测得水样中磷酸盐的含量。
三、实验仪器与试剂1. 仪器:- 分光光度计- 磷酸盐标准溶液- 磷钼蓝分光光度法GB/T 5750.5-2006- 实验室常规玻璃仪器(如锥形瓶、容量瓶、吸管等)2. 试剂:- 硫酸溶液(体积比1:1)- 氯化亚锡甘油溶液(10%)- 钼酸铵- 硫酸混合试剂(体积比1:1)- 钼酸铵溶液(0.5%)- 标准贮备溶液- 标准使用溶液四、实验步骤1. 标准曲线绘制:- 分别吸取0 mL、0.50 mL、1.00 mL、2.00 mL、3.00 mL、4.00 mL、5.00 mL 的磷酸盐标准溶液于7个具塞离心管中,用蒸馏水稀释至刻度,摇匀。
- 分别加入5 mL硫酸混合试剂,混匀。
- 加入1 mL钼酸铵溶液,混匀。
- 加入0.5 mL氯化亚锡甘油溶液,混匀。
- 在波长660 nm处,用1 cm比色皿,以蒸馏水为参比,测定吸光度。
- 以磷酸盐浓度为横坐标,吸光度为纵坐标,绘制标准曲线。
2. 样品测定:- 取适量水样于锥形瓶中,加入硫酸混合试剂,混匀。
- 按照标准曲线绘制步骤,测定水样吸光度。
3. 结果计算:- 根据水样吸光度,从标准曲线上查得对应磷酸盐浓度。
- 计算水样中磷酸盐含量。
五、实验结果与分析1. 标准曲线绘制结果:- 标准曲线线性良好,相关系数R²大于0.99。
2. 样品测定结果:- 水样中磷酸盐含量为0.25 mg/L。
3. 结果分析:- 本实验采用磷钼蓝分光光度法测定水样中磷酸盐含量,方法准确可靠。
- 标准曲线线性良好,相关系数R²较高,说明实验方法稳定。
BOD分析仪-仪器百科
简介BOD分析仪即生物需氧量分析仪,是用来分析某水体的即生物需氧量的仪器。
生物需氧量(BOD)是微生物在一定量的水体中生长所消耗的氧气的量,是一种环境监测指标,主要用于监测水体中有机物的污染状况。
原理BOD在线分析仪,是带有液体流路自动切换系统的光学BOD速测仪,可快速测定水中BOD,水样中溶解性可生化降解的有机物受到微生物菌膜中菌种的同化作用,菌种的细胞呼吸强度增强,而使水中氧的质量减少,当水样中可生化降解的有机物向菌膜扩散速度(质量)达到恒定时,相关的生化反应便稳定下来,此时光学信号与水样中可生化降解的有机物浓度存在定量关系,因此该信号经转化为电流信号后经放大、分析处理,便可直接将BOD检测结果显示出来。
产品基本应用BOD分析仪广泛适用于材料、化工、制药、精细陶瓷、造纸、化妆品、冶金等行业以颗粒物作为生产原料或中间体的实验室分析和工业生产中质里控制等诸多领域。
分类BOD测定仪器主要有以生物传感器法为原理的BOD速测仪、压力法BOD测定仪、溶氧仪BOD测定仪。
1、BOD速测仪含有饱和溶解氧的水样进入测定槽与生物传感器接触,产生一个恒定电流。
当水样中有可生化降解的有机物又产生一个恒定电流。
两个恒定电流之间的差值与水样中可生化降解的有机物浓度存在定量关系,因此该电流信号经微机放大、分析处理后,直接将BOD检测结果显示出来。
2、压力法BOD测定仪在一个密闭系统中,样品中的微生物消耗氧气同时生成二氧化碳,生成的二氧化碳被NaOH药丸吸收,导到气压发生变化,通过一个压力传感器感测压力变化并转换成BOD值。
3、溶氧仪BOD测定仪基于特定物质对活性荧光的猝熄原理。
蓝光照射到荧光物质上使荧光物质激发并发出红光,由于氧分子可以带走能量(猝熄效应),所以激发的红光的时间和强度与氧分子浓度成反比。
通过测量激发红光与参比光的相位差,并与内部标定值对比,从而可计算出氧分子的浓度。
操作规范第一步:预先打开培养箱开关,设定温度为20℃(要求培养箱的恒温变化幅度为±1℃)。
Navigator 600磷酸盐分析器说明书
Navigator 600 Phosphate Phosphate analyzerCost-effective automated monitoring of phosphate forsteam raising applicationsLowest cost-of-ownership—up to 90 % lower reagent consumption than competitors' analyzers—labour-saving 5 minute annual maintenance and up to 6 months unattended operation—field upgradeable from 2 to 4; 2 to 6; 4 to 6 streams Easy to use—familiar Windows™ menu system —built-in context-sensitive helpFull communications—web- and ftp-enabled for easy data file access, remote viewing and configuration —optional Profibus ® DP V1.0Fast, accurate and reliable—automatic cleaning, automatic calibration and automatic zero deliver high accuracy measurements—extensive electronics, measurement and maintenance diagnostics ensure high availability —indication in PO 4 or P—temperature-controlled reaction and measurement section for optimum responseNavigator 600 Phosphate Phosphate analyzer2DS/NAV6P–EN Rev. GIntroductionMany years of experience and innovation in the design and successful application of continuous chemical analyzers has been combined with the latest electronics and production technologies to produce the Navigator 600 Series of analyzers from ABB.Developed as fully continuous analyzers offering wide dynamic ranging, the Navigator 600 Series incorporates greater simplicity and functionality than ever before. Based on colorimetric techniques, they feature a liquid-handling section carefully designed to reduce routine maintenance. Utilizing powerful electronics, advanced features such as automatic calibration,continuous sample analysis and programmable multi-stream switching ensure accurate and simple measurement of phosphate.Process data, as well as the content of alarm and audit logs,can be saved to a removable SD card in binary and comma-delimited formats for record keeping and analysis using ABB’s DataManager data analysis software package.A very low cost of ownership has been achieved by reducing the reagent consumption and simplifying the maintenance requirements.The size of the analayzer has been reduced to a compact,ergonomically-designed, wall-mounted case containing all the components.OperationGeneralThe Navigator 600 Phosphate is an on-line analyzer, designed to provide continuous monitoring of phosphate concentration,utilizing a standard colorimetric analysis principle.Liquid HandlingThe chemistry employed for phosphate measurement is the industry standard Molybdenum Blue reaction. Sample and reagents are drawn into the analyzer by two multichannel peristaltic pumps. These are designed and constructed to ensure that only simple yearly maintenance is required. The reagents are added to the sample in a temperature-controlled reaction block and the fully reacted sample is then passed through an in-line measuring cuvette.The optical measuring system enables accurate detection of phosphate concentrations from 0 to 15 ppm phosphate (PO 4)(0to 5ppm phosphorous [P]).The analyzer also includes a manual sampling facility that enables the analysis of grab samples.Solution ReplacementLiquid Handling Section ContinuousReagents3 months Calibration Standard 3 months Cleaning Solution3 monthsNavigator 600 Phosphate Phosphate analyzerDS/NAV6P–EN Rev. G 3ElectronicsThe electronics are mounted on the analyzer's back plate with the display and key pad accessible from the front of the unit.Indication of all parameters is provided by a large backlit LCD display that is easy to read in all light conditions. Under normal operating conditions, measured values are displayed;programming data is displayed during set-up and also on demand. Units and range of measurement, alarm values and standard solution values are examples of the many programmable functions.Keeping simplicity of operation at the forefront of design, six fingertip-operated tactile membrane switches control local operation of the analyzer and provide easy access to all parameters.The Navigator 600 Phosphate is provided with 4 dedicated relays, 6user-programmable relays and 6 current outputs as standard. Profibus DP V1.0 is available as an option.Ethernet CommunicationsThe Navigator 600 Phosphate can provide 10BaseT Ethernet communications via a standard RJ45 connector and uses industry-standard protocols TCP/IP , FTP and HTTP . The use of standard protocols enables easy connection into existing PC networks.Data File Access via FTP (File Transfer Protocol)The Navigator 600 Phosphate features FTP server functionality.The FTP server in the analyzer is used to access its file system from a remote station on a network. This requires an FTP client on the host PC. Both MS-DOS® and Microsoft® Internet Explorer version 5.5 or later can be used as an FTP client.⏹Using a standard web-browser or other F TP client, datafiles contained within the analyzer's memory or memory card can be accessed remotely and transferred to a PC or network drive.⏹Four individual FTP users' names and passwords can beprogrammed into the Navigator 600 Phosphate. An access level can be configured for each user.⏹All FTP log-on activity is recorded in the audit log of theinstrument.⏹Using ABB’s data file transfer scheduler program, datafiles from multiple instruments can be backed-up automatically to a PC or network drive for long-term storage, ensuring the security of valuable process data and minimizing the operator intervention required.Display and KeypadChart View DisplayNavigator 600 Phosphate(FTP Server)Navigator 600 Phosphate(FTP Server)FTP ClientEthernetNavigator 600 Phosphate Phosphate analyzer4DS/NAV6P–EN Rev. GEmbedded Web ServerThe Navigator 600 Phosphate has an embedded web-server that provides access to web pages created within the instrument. The use of HTTP (Hyper Text Transfer Protocol)enables standard web browsers to view these pages.⏹Accessible through the web pages are the current displayof the analyzer, detailed information on stream values,reagent and solution levels, measurement status and other key information.⏹The audit and alarm logs stored in the Navigator 600Phosphate's internal buffer memory and memory card can be viewed on the web pages.⏹Operator messages can be entered via the web server,enabling comments to be logged to the instrument.⏹The web pages and the information they contain arerefreshed regularly, enabling them to be used as a supervision tool.⏹The analyzer's configuration can be selected from anexisting configuration in the internal memory or a new configuration file transferred to the instrument via FTP .⏹The analyzer's real-time clock can be set via the webserver. Alternatively, the clocks of multiple analyzers can be synchronized using ABB's F ile Transfer Scheduler software.Email NotificationVia the Navigator 600 Phosphate's built-in SMTP client, the analyzer is able to email notification of important events. Emails triggered from alarms or other critical events can be sent to multiple recipients. The analyzer can also be programmed to email reports of the current measurement status or other parameters at specific times during the day.ProfibusThe Navigator 600 Phosphate can be equipped (option) with Profibus DP V1.0 to enable full communications and controlintegration with distributed control systems.Navigator 600 Phosphate Phosphate analyzerDS/NAV6P–EN Rev. G 5MaintenanceThe analyzer has been designed to maximize on-line availability by reducing routine maintenance to a minimum.Yearly maintenance consists of simply replacing pump capstans and pump tube assemblies, an operation that can take as little as five minutes.F ully automatic calibration, zeroing and cleaning functions enable the analyzer to keep itself operational with minimal manual intervention. A predictive alarm alerts the user before cleaning, calibration or reagent solution replacement is required.OptionsMulti-stream FacilityA fully programmable multi-stream option is available on the Navigator 600 Phosphate on-line analyzer, providing up to six-stream capability including individual current output and visual indication as well as user-programmable stream sequencing.The analyzers are designed to be easily upgradeable in the field from 2 to 4 or 6 streams and from 4 to 6 streams.Simple to Replace Pump Tube AssembliesSix Streams DisplayNavigator 600 Phosphate Phosphate analyzer6DS/NAV6P–EN Rev. GSpecificationPhosphate MeasurementRangeFully user programmable 0 ... 15 ppm PO 4 (0 ... 5 ppm P), minimum range 0 ... 1 ppm PO 4 ( 0 ... 0.33 ppm P)Measurement ModesContinuousContinuous measurement operationSample stream selectionAvailable in 1, 2, 4 or 6 streams (4 and 6 stream configurations can accommodate 3 and 5 streams respectively, if required)Measurement PerformanceResponse time<15 mins. (90 % step change)Typical accuracy<±3 % of reading or ±0.1 ppm (whichever is the greater) over the range 0 ... 10 ppm PO 4<±5 % of reading over the range 10 ... 15 ppm PO 4Repeatability<±1.5 % of reading or ±0.05 ppm (whichever is the greater) over the range 0 ... 10 ppm PO 4<±2.5 % of reading over the range 10 ... 15 ppm PO 4RangeAuto Ranging 0.00 ... 2.99 /3.0 ... 15.0Solution RequirementsNumber 2 reagents 2 standard solution 1 cleaning solution Volume2.5 l max. per reagent 500 ml per standard solution 500 ml cleaning solutionReagent ConsumptionContinuous operation mode 2.5 l max. per 90 daysDisplayColor, passive matrix, liquid crystal display (LCD) with built-in backlight and contrast adjustment 76800 pixel display**A small percentage of the display pixels may be either constantly active or inactive. Max. percentage of inoperative pixels <0.01%.Dedicated operator keys⏹Group Select/Left cursor ⏹View Select/Right cursor ⏹Menu key ⏹Up/Increment key ⏹Down/Decrement key ⏹Enter keyMechanical DataIngress protectionIP31** – Wet section (critical components IP66)IP66 – Transmitter Dimensions Materials of construction Environmental DataAmbient Operating Temperature 5 ... 45 ºC (41 ... 113 ºF)Sample Temperature 5 ... 55 ºC (41 ... 131 ºF)Sample Particulate <60 microns <10 mgl –1Sample Flow Rate>20 mls/min / <500 ml/min Storage Temperature–20 ... 75 ºC (–4 ... 167 ºF)Ambient Operating Humidity Up to 95 % RH non-condensing **Not evaluated for UL or CBDiagonal display area 144 mm (5.7 in.)Height 638 mm (25.1 in.) plus constant headbracket 186 mm (7.3 in.)Width 271 mm (10.7 in.)Depth182 mm (7.2 in.)Weight15 kg (33 lbs)Electronics enclosure 20 % glass loaded polypropylene Main enclosure NorylLower tray 10 % glass loaded polypropylene DoorAcrylicNavigator 600 Phosphate Phosphate analyzerDS/NAV6P–EN Rev. G 7ElectricalSupply ranges110 to 240 V max. AC 50/60 Hz ± 10 % (90 to 264 V AC, 45/65 Hz)18 to 36 V DC (optional)Power consumption 60 W max. – AC 100 W max. – DCAnalog OutputsSingle and multi-stream analyzers6 isolated current outputs, fully assignable and programmable over a 0 ... 20 mA range (up to 22 mA if required)Alarms/Relay OutputsSingle and multi-stream instruments One per unit:⏹Out of service alarm relay ⏹Calibration in progress alarm relay ⏹Calibration failed alarm relay ⏹Maintenance/Hold alarm relaySix per unit:⏹fully user-assignable and alarm relaysRating Wetted MaterialsPMMA (acrylic)PP (polypropylene)PTFEPP (20% glass filled)PEEK NBR (nitrile)EPDM SantoprenePTFE (15% polysulphane)NORYLBorosilicate glass Acrylic adhesiveConnectivity/CommunicationsEthernet connection Bus communicationsProfibus DP V1 (optional)Data Handling, Storage and DisplaySecurityStorageRemovable Secure Digital (SD) card Trend analysis Local and remote Data transfer SD card or FTPApprovals, Certification and SafetySafety Approval cULus – pendingCE MarkCovers EMC & LV Directives (including latest version EN 61010)General Safety EN 61010–1Overvoltage Class 11 on inputs and outputs Pollution category 2EMCEmissions & immunityMeets requirements of IEC61326 for an Industrial EnvironmentVoltage 250 V AC 30 V DC Current5 A AC 5 A DC Loading (non-inductive)1250 VA150 WWeb server with ftp:for real time monitoring, configuration, data file access and email capabilityMulti level security:user, configuration, calibration and maintenance pagesNavigator 600 Phosphate Phosphate analyzer Overall DimensionsNavigator 600 Phosphate8DS/NAV6P–EN Rev. GNavigator 600 PhosphatePhosphate analyzerReagent Bottles Mounted on Optional BracketDS/NAV6P–EN Rev. G9Navigator 600 Phosphate Phosphate analyzer10DS/NAV6P–EN Rev. GOrdering InformationSupplied with analyzer:Reagent and calibration solution containersPhosphate Analyzer AW642/XXXXXXXXRange0 ... 15 ppm 5Number of Streams1 – Measuring 1 stream2 – Measuring 2 streams 4 – Measuring3 or4 streams 6 – Measuring5 or6 streams 1246CommunicationsNoneProfibus DP . V .101EnclosureStandardStandard + reagent shelf 01Power Supply110 ... 240 V AC 50/60 Hz 18 ... 36 V DC 01ReservedBuild 9ManualEnglish French Italian German Spanish 12345CertificationNoneCertificate of calibration cULus – pending012Navigator 600 Phosphate Phosphate analyzerDS/NAV6P–EN Rev. G 11Benefits Summary⏹Lowest cost-of-ownership–up to 90 % lower reagent consumption than competitors' analyzers–labour-saving 5 minute annual maintenance and up to 6 months unattended operation⏹Easy to use–familiar Windows menu system –built-in context-sensitive help⏹Full communications–web- and ftp-enabled for easy data file access,remote viewing and configuration –optional Profibus DP V1.0⏹Fast, Accurate and Reliable–temperature-controlled reaction and measurement section for optimum response–automatic cleaning, calibration and zero deliver high accuracy measurements–extensive electronics, measurement and maintenance diagnostics ensure high availability⏹Field upgradeable–2 to 4 or 6 streams; also from 4 to 6 streams, each user-programmable from 0 to 15 ppm⏹Compact size–638 mm (25.1 in.) H x 271 mm (10.7 in.) W x 182 mm (7.2 in.) D⏹Email facility–automatically email up to 6 recipients when user-selected events occur⏹Grab sample facility–for manual sampling⏹Multiple outputs and relays–6 current outputs, 4 device state and 6 user-programmable relays as standard⏹Archiving facility–SD data card for easy backup and programming⏹Instrument logs–alarm and audit logs for complete, secure recordsContact usD S /N A V 6P –E N R e v . G 10.2011ABB LimitedProcess Automation Oldends Lane StonehouseGloucestershire GL10 3TA UK Tel:+44 1453 826 661Fax:+44 1453 829 671ABB Inc.Process Automation 125 E. County Line Road Warminster PA 18974USA Tel:+1 215 674 6000Fax:+1 215 674 NoteWe reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.We reserve all rights in this document and in thesubject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB.Copyright© 2011 ABB All rights reserved 3KXA842602R1001Windows™, Microsoft™, MS-DOS™ and Internet Explorer™ are registered trademarks of Microsoft Corporation in the United States and / or other countries.PROFIBUS™ is a registered trademark of PROFIBUS corporation.。
双指示剂法滴定磷酸盐法操作步骤
双指示剂法滴定磷酸盐法操作步骤下载提示:该文档是本店铺精心编制而成的,希望大家下载后,能够帮助大家解决实际问题。
文档下载后可定制修改,请根据实际需要进行调整和使用,谢谢!本店铺为大家提供各种类型的实用资料,如教育随笔、日记赏析、句子摘抄、古诗大全、经典美文、话题作文、工作总结、词语解析、文案摘录、其他资料等等,想了解不同资料格式和写法,敬请关注!Download tips: This document is carefully compiled by this editor. I hope that after you download it, it can help you solve practical problems. The document can be customized and modified after downloading, please adjust and use it according to actual needs, thank you! In addition, this shop provides you with various types of practical materials, such as educational essays, diary appreciation, sentence excerpts, ancient poems, classic articles, topic composition, work summary, word parsing, copy excerpts, other materials and so on, want to know different data formats and writing methods, please pay attention!标题:双指示剂法滴定磷酸盐法操作步骤---引言在化学分析领域,双指示剂法滴定磷酸盐是一种常用的定量分析方法。
总磷在线水质分析仪器的工作原理
总磷在线水质分析仪器的工作原理总磷是什么?水中磷可以元素磷、正磷酸盐、缩合磷酸盐、焦磷酸盐、偏磷酸盐和有机团结合的磷酸盐等形式存在。
总磷的重要来源为生活污水、化肥、有机磷农药及近代洗涤剂所用的磷酸盐增洁剂等。
总磷是水样经消解后将各种形态的磷变化成正磷酸盐后测定的结果,以每升水样含磷毫克数计量。
1、方法原理在酸性条件下,正磷酸盐与钼酸铵、酒石酸锑氧钾反应,生成磷钼杂多酸,被还原剂抗坏血酸还原,则变成蓝色络合物,通常集成磷钼蓝。
本方法检出浓度为0.01mg/L(吸光度A=0.01时所对应的浓度);测定上限为0.6mg/L。
可适用于测定地面水、生活污水及日化、磷肥、机加工金属表面磷化处理、农药、钢铁、焦化等行业的工业废水中的正磷酸盐分析。
2、仪器分光光度计3、试剂(1)1+1硫酸。
(2)10%(m/V)抗坏血酸溶液:溶解10g抗坏血酸于水中,并稀释至100ml。
该溶液储存在棕色玻璃瓶中,在冷处可稳定几周。
如颜色变黄,则弃去重配。
(3)钼酸盐溶液:溶解13g钼酸铵[(NH4)6Mo7O24·4H2O]于100ml水中。
溶解0。
35g酒石酸锑氧钾[K(SbO)C4H4O6·1/2H2O]于100ml水中。
在不断的搅拌下,将钼酸铵溶液缓缓加到300ml(1+1)硫酸中,加酒石酸锑钾溶液并且混合均匀。
试剂贮存在棕色的玻璃瓶中于冷处保存。
至少稳定2个月。
(4)浊度色度补偿液:混合两份体积的(1+1)硫酸和一份体积的10%(m/V)抗坏血酸溶液。
此溶液当天配制。
(5)磷酸盐储备溶液:将磷酸二氢钾(KH2PO4)于110°C干燥2h,在干燥器中放冷。
称取0.217g溶于水,移入1000ml容量瓶中。
加(1+1)硫酸5ml,用水稀释至标线。
此溶液每毫升50.0ug磷。
(6)磷酸盐标准溶液:吸取10.00ml磷酸盐储备液于250ml容量瓶中,用水稀释至标线。
此溶液每毫升含2.00ug磷。
临用时现配。
总磷全自动在线分析仪常用试剂配制方法
总磷全自动在线分析仪常用试剂配制方法1、磷标准贮备溶液,1000mg/L。
a.将磷酸二氢钾于110℃干燥2h。
b.用小烧杯称取4.394g于110℃干燥2h在干燥器中放冷的邻苯二甲酸氢钾,溶于蒸馏水中,移入1000mL容量瓶,并用蒸馏水定容至刻度线,摇匀后使用。
需要的仪器及玻璃仪器:万分之一天平、玻璃棒、50mL烧杯、1000mL容量瓶。
2、标准使用液的配制标一:0.5mg/L,用10mL刻度移液管准确移取0.5mL浓度为1000mg/L的磷标准贮备溶液于1000mL容量瓶中,并用蒸馏水定容至刻度线,摇匀后使用。
标二:7.5 mg/L, 用10mL刻度移液管准确移取7.5mL浓度为1000mg/L的磷标准贮备溶液于1000mL容量瓶中,并用蒸馏水定容至刻度线,摇匀后使用。
用1000mg/L磷标准贮备溶液配制不同浓度的常用标液配制如下表:3、抗坏血酸,25g/L 。
用小烧杯称取25g抗坏血酸,溶于蒸馏水,移入1000mL容量瓶,并用蒸馏水定容至刻度线。
使用的玻璃仪器:50mL烧杯、玻璃棒、1000mL容量瓶。
4、过硫酸钾,25g/L 。
用小烧杯称取25g过硫酸钾,溶于蒸馏水,移入2000mL容量瓶,并用蒸馏水定容至刻度线。
使用的玻璃仪器:50mL烧杯、玻璃棒、2000mL容量瓶。
5、(1+1)硫酸溶液配制a.用250mL量筒量取250mL的蒸馏水,并倒入1000mL烧杯中。
b.用250mL量筒量取250mL的浓硫酸。
c.在不断搅拌下将250mL的浓硫酸徐徐加入到250mL的蒸馏水中,冷却后倒入500mL试剂瓶中备用。
使用的玻璃仪器:50mL烧杯、玻璃棒、250mL量筒、1000mL烧杯。
6、钼酸盐溶液a.用烧杯称20g钼酸铵,溶解于100mL水中。
b.用称量纸称0.2g酒石酸锑钾,溶解于100mL水中。
c.用100mL量筒量取90mL(1+1)硫酸,并倒入1000mL烧杯中。
d.在不断搅拌下把钼酸铵溶液徐徐加到90mL(1+1)硫酸中,再加酒石酸锑钾溶液,加蒸馏水至1000mL刻度线,混合均匀使用。
LANGE PHOSPHAX sigma总磷在线分析仪 说明书
4
使用说明书
3 组装
3.1 光度计的外表及尺寸
总磷分析仪 PHOSPHAX Σ sigma
图 1 尺寸图
5
使用说明书 3.2 安装环境
总磷分析仪 PHOSPHAX Σ sigma
现场应干燥,不要暴露在太阳光线直接照射下
8.1 维护时间间隔
37
8.2 维护工作
38
8.2.1 更换各种药剂
38
8.2.2 清洗
40
8.3 分析质量保证系统
40
8.4 出错信息
41
9 各种药剂和备件 ···················································42
10 技术数据 ·································································43
板上(图 4)。
把位于制冷器顶部的节 温器旋钮旋转到 5-6。
控制电缆
光度计的底板 图 4 风扇板
控制电缆的连接
7
使用说明书
总磷分析仪 PHOSPHAX Σ sigma
3.3 进水和排水软管的连接
水试样供给软管(约 1.2 米长)位于外壳的左侧, 任何情况也不能缩短或伸长。 它专门设计通过 SIGMATAX 2 装置供应水试样。在此软管上有一 个排水软管用外侧壁接口的平行双槽管子活接头 (LZP 573),它很容易从外侧塞入(参见图 5)。 所有外面的软管应尽布置可能圆滑的走向,即避
3
使用说明书
总磷分析仪 PHOSPHAX Σ sigma
1 担保和责任
总磷在线分析仪
总磷在线分析仪总磷是水体中的一种重要指标,主要用于评估水质的污染程度和环境的健康状况。
传统的总磷检测方法繁琐且时间长,且需要专业的实验室设备和人员操作。
然而,随着科技的发展,总磷在线分析仪的出现极大地提高了检测效率和准确度。
本文将介绍总磷在线分析仪的原理、应用和未来发展趋势。
总磷在线分析仪是一种基于光学技术的仪器,可以实时监测水体中总磷浓度。
它的工作原理是通过特定的光谱技术,利用水中总磷对特定波长光线的吸收特性进行测量。
通过测量水样吸收率的变化,可以准确计算出水中总磷的浓度。
总磷在线分析仪具有快速、准确和自动化的特点,可以连续监测水质,提供关键的数据支持。
总磷在线分析仪在环境保护、水资源管理和工业生产中具有广泛的应用。
首先,在环境保护方面,总磷在线分析仪可以用于湖泊、河流和水库等水体的监测,帮助评估水体污染程度,及时采取措施进行治理和保护。
其次,在水资源管理方面,总磷在线分析仪可以用于水厂和自来水管网的监测,确保供水的安全稳定。
此外,在工业生产中,总磷在线分析仪可以用于废水处理厂的监测,帮助控制废水中总磷浓度,保护环境。
总磷在线分析仪的发展仍处于初级阶段,但具有广阔的发展前景。
首先,随着科技的进步,总磷在线分析仪的检测精度将不断提高,最小检测浓度的范围将进一步扩大,从而更好地满足实际应用的需求。
其次,总磷在线分析仪的自动化程度也将逐渐提高,操作更加简便方便,减少了人力资源的需求。
再次,随着总磷监测需求的增加,总磷在线分析仪将会变得更加智能化,可以与其他水质监测设备进行联动,实现数据的共享和分析。
最后,还有待研发更多功能更加强大的总磷在线分析仪,以满足复杂水体的监测需求,并探索更多的应用领域。
总之,总磷在线分析仪是一种快速、准确和自动化的水质监测仪器,具有广泛的应用前景。
它可以实时监测水体中总磷浓度,帮助评估水质的污染程度和环境的健康状况。
随着技术的不断发展,总磷在线分析仪的性能将不断提高,功能将更加强大,为水质监测和环境保护提供更好的支持。
磷酸盐测定仪
磷酸盐测定仪简介磷酸盐测定仪是一种测定溶液中磷酸盐含量的仪器。
磷酸盐是一种广泛存在于自然界中的无机化合物,对于农业、环保等方面有着重要的作用。
因此,对磷酸盐含量的测定是十分必要的。
工作原理磷酸盐测定仪的主要工作原理是莫尔反应。
具体操作流程如下:1.将样品溶液与莫尔试剂混合。
2.在酸性条件下,磷酸根离子会与莫尔试剂中的钼酸根离子结合,生成孔雀石绿复合物。
3.随后,用分光光度法测光密度,通过与标准曲线的对比,便可测定出样品中磷酸盐的含量。
仪器组成磷酸盐测定仪主要由以下组成部分构成:1.试剂盒:包含莫尔试剂、钼酸铵、硫酸、样品等用品。
2.分光光度计:用于测量孔雀石绿复合物的光密度。
3.试管架:用于支撑试管等试剂容器。
4.精密移液器:用于定量移取样品和试剂。
操作步骤1.取一个干净的试管,将待测样品加入其中,用去离子水稀释至适当浓度(一般进行5倍至50倍的稀释)。
2.取出试剂盒中钼酸铵试剂,加入样品中,之后加入莫尔试剂。
注意在加入试剂时,要保证试剂混合均匀,样品中不应出现物理变化。
3.加入适量的浓硫酸混合均匀。
注意操作时要小心,以免发生意外。
4.放置反应液10分钟左右,反应后的溶液呈蓝色,此时可以将反应容器取到分光光度计中。
5.测定波长为710nm的吸光度。
根据原始数据计算得出样品中磷酸盐的含量。
注意事项1.操作时要小心谨慎,避免发生意外。
2.试剂浓度和混合比例需按照说明书进行配制,避免误差。
3.注意保持仪器干净、不受灰尘等污染,以保证测试的准确性。
总结磷酸盐测定仪是一种通用型实验仪器,广泛应用于农、环保等领域中,对于磷酸盐含量测定具有非常高的准确度和稳定性。
正确、规范的操作流程可以最大程度的发挥磷酸盐测定仪的作用。
9211-磷表简介
盘装尺寸 墙装机柜尺寸
样水 连接
分析
样水通道数 温度 压力 / 流速
样水管线
排放 环境温度 电源
测量范围 再现性 检测极限 循环时间
校准
变送器
保护 E.C. 标准 U.L. 数字式背光显示
编程 电流输出 继电器输出
远程控制
可选项
RS485
材料 维护
盘装 墙装机柜 重量
每 45 天
TE 9211=A=100 - RevB.qxd
技术规格
1 ~ 6 通道,可编程时序 5 ~ 50 ºC ( 41 ~122 ºF ) 0,2 ~ 6 bar ( 3 ~ 87 psi ),在取样阶段 15 ~ 20 l / h
简易管接件 / 连接器用于 6 mm (1/4") PE (聚乙烯) / PTFE (聚四氟乙烯) 外直径管 管接件用于 12 (1/2") x 10 mm PE (聚乙烯) 内直径管 5 ~ 45 º C ( 41 ~113 º F ) 100 ~ 240 VAC,± 10 %,50/60 Hz,~ 50 VA
- 硅的浓度报警 - 样水不足报警 - 当前运行通道 二个触点用于: - 警告 ( 试剂/校准溶液低液位,无样水等) - 系统报警 ( 校准错误,硬件故障,等等),在正或
负极限的安全区域操作,最大 30 VDC,0,5 A - 样水通道开通 / 关闭 - 报警确认
300 ~ 9600 波特率,最多站点 32, JBUS/MODBUS,Profibus 请咨询我们
传真:( 010 ) 62954334
9211 磷表, 用户友好的多通道磷酸盐分析仪
- 化学
9211 磷表使用的所有试剂都可以到当地化学试 剂商店购买其优级纯产品。它独特的试剂组成可 确保仪表在整个测量过程中的稳定性,从而保证 磷表测量的可靠性和重现性
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
重量尺寸 防、市政污水、工业废水等。
技术参数:
测量原理 测量范围 准 确 度 重 复 性 检出极限 测量时间 零点漂移 量程漂移 分 辨 率 信号输出 工作环境 电 源 钼酸铵分光光度法 0-2/5/20/100 mg/L,更多量程可选 <±3%或0.003 mg/L,取较大值 <1% 0.0025mg/L(最小量程) 15分钟 <1%FS/24h <1%FS/24h 0.0001mg/L(最小量程) 4-20mA RS232/485 MODBUS/TCP 温度:0~45℃;湿度:10~95% 220±10%伏 50±2%赫兹 重量:约45公斤;尺寸:H*L*W=1100*600*310mm IP54;IP65 无油无悬浮物;温度:2~40℃;压力:0.0~0.1Bar;流量:1.5~3L/min
PowerMon 在线磷酸盐分析仪
性能特点:
※ 全自动分析、自动清洗,周期任意设定 ※ 自动校准、手动校准、网络远程校准 ※ 超低的检出极限 ※ 超高精度蠕动泵实现液体输送,确保超高的测量重现性 ※ 模块化设计、维护简便、量程可调可扩展 ※ 具备质控样核查验证、工作状态远程监控及数据可靠性诊断功能 ※ 触摸屏操作及显示,菜单式操作界面 ※ 故障报警、出错报警、来电自启功能 ※ 支持4-20mA、RS232/485数据传输以及MODBUS/TCP等通讯方式