EBW-EA560型装置说明书

合集下载

EA600说明书

EA600说明书

目录一、概述1.1 产权说明····································································1.2 铭牌说明···································································1.3 型号说明································································1.4 选型说明································································1.5 开箱说明···································································1.6 功率分布表····································································1.7 制动单元和制动电阻选择································二、安装和接线2.1 基准型机箱尺寸······························································2.2 基准型机箱安装要求····································································2.3 接线要求····································································2.4 接线说明····································································三、操作面板及安全事项3.1 面板尺寸示意图····························································3.2 面板按键说明···························································3.3 面板指示灯说明····························································3.4 参数修改方法····························································3.5 安全注意事项····································································四、功能参数一览表五、功能详细介绍5.1 主要功能方面参数····························································5.2 前驱动对象(电机)方面参数··················································5.3 矢量控制方面参数····························································5.4 V/F控制方面参数·····························································5.5 附加功能方面参数····························································5.6 PID控制方面参数·····························································5.7 多段速控制方面参数··························································5.8 保护功能方面参数·····························································5.9 起停控制方面参数·····························································5.10 输入端子功能方面参数·························································5.11 输出端子功能方面参数·························································5.12 人机界面方面参数·····························································5.13 485通信方面参数·····························································六、变频器RS485通讯协议6.1 通讯协议····································································6.2 协议内容····································································6.3 应用方法····································································6.4 总线结构····································································6.5 协议说明····································································6.6 通讯帧结构··································································6.7 命令码及通讯资料描述························································七、故障咨询及对策7.1 故障类型及处理办法··························································7.2 其它故障案列分析··························································八、标准规范8.1 规格型号····································································8.2 公共特性····································································8.3 显示········································································九、选件9.1 选件表······································································9.2 周边选件与变频器的连接图····················································9.3 外引线及连接示意图················十、变频器的维护10.1 日常检查····································································10.2 定期检查····································································10.3 除尘········································································10.4 零部件的更换································································十一、品质承诺11.1 保修范围···································································11.2 三包规定····································································11.3 维权规定········································································第一章 概 述1.1产权说明本公司生产的系列变频器已申请有以下专利,未经本公司授权请不要侵权,否则将予以法律追究。

ALTO 560 B 机器人操作手册说明书

ALTO 560 B 机器人操作手册说明书

Operator'sManualModel560 BForm No. 999836 3/99Clarke Technology Printed in the U.S.A.Table of ContentsOperator Safety Instructions (3)How To Prepare The Machine For Operation (4)How To Assemble the Handle (4)How To Install the Dust Bag (4)How To Install the Paper Filter Bag (5)How To Start the Machine (5)How To Change the Brush Segments (5)Instructions for Connection to the Power Supply and the Electrical Ground (6)Maintenance (7)Assembly Drawing (8)Parts List (9)Page -2- Clarke Technology Operator's Manual Model 560 BClarke Technology Operator's Manual Model 560 BPage -3-OPERATOR SAFETY INSTRUCTIONSWARNINGAVERTISSEMENTADVERTENCIADANGER:WARNING:DANGER:Failure to read the Owner's Manual prior to operating or attempting any service or maintenance procedure to your ALTO machine could result in injury to you or to other personnel; damage to the machine or to other property could occur as well.You must have training in the operation of this machine before using it. If your operator(s) cannot read English, have this manual explained fully before attempting to operate this machine.DANGER:Operating a machine that is not completely or fully assembled could result in injury or property damage. Do not operate this machine until it is completely assembled.Inspect the machine carefully before operation.DANGER:Machines can cause a fire when operated near flammable materials and vapors.Do not use this machine with or in areas near flammable fluids, fuels, grain dust,solvents, thinners, vapors or other flammable materials. This machine is not suitable for picking up hazardous dust.WARNING:To prevent electrical shock, always remove the electrical plug from the electrical outlet before doing any repairs or maintenance to this machine.WARNING:To prevent injury, always remove the electrical plug from the electrical outlet before changing the brush or accessories and before leaving the machine.WARNING:Maintenance and repairs performed by unauthorized personnel could result in damage or injury. Maintenance and repairs must be performed by authorized Clarke Technology personnel only.WARNING:Any alterations or modifications of this machine could result in damage to the machine or injury to the operator or other bystanders. Alterations or modifications not authorized by the manufacturer voids any and all warranties and liabilities.WARNING:To prevent electrical shock, do not use this machine on wet surfaces. Electrical compo-nents of this machine can "short-out" if exposed to water or moisture. Keep the electri-cal components of the machine dry. Protect the machine from rain. For storage, keep the machine in a dry building. Always clean the machine with a clean dry cloth.WARNING:To prevent damage to the power cord, do not let the brush touch the power cord when the machine is running. Always lift the cord over the machine.WARNING:Operating a machine without observing all labels and instructional information could result in injury or damage. Read all machine labels before attempting to operate. Make sure all of the labels and instructional information are attached or fastened to the ma-chine. Get replacement labels and decals from your distributor.CAUTION:Use of this machine to move other objects or to climb on could result in injury or dam-age. Do not use this machine as a step or furniture. Do not ride on this machine.Figure 1Figure 21122Figure 3Figure 4Page -4- Clarke Technology Operator's Manual Model 560 BClarke Technology Operator's Manual Model 560 BPage -5-3.Slide the clamp over the folded edge of the dustbag. Make sure the paper bag is included (see figure 6.)To start the machine, do the following:1.Step on the release lever.2.Lower the handle (see figure 7.)When the brush bristles become worn, replace the brush segments. To change the brush segments,follow this procedure:1.Turn the levers (figure 8, #1), that hold the plate, tothe left.2.Remove the nozzle plate (figure 8, #2).3.Remove the brush roller (figure 8, #3).4.Remove the four screws from each half (figure 8,#4).5.Install the new brush sections.Figure 5Figure 6Figure 7Figure 8112443Page -6-Clarke Technology Operator's Manual Model 560 BFigure 9(C). This adapter must be connected as shown in Figure 9(B) to an electrical ground in the electrical outlet. Make sure you use a plate screw and the ground tab to fasten the adapter.WARNING:Always use this machine with an AC three-conductor electrical system connected to the electri-cal ground. Replace any worn,cut or damaged cords. Replace any damaged plugs, receptacles or connector bodies.WARNING:For maximum protection against electric shock, use an electrical circuit interrupter. Get this device from your electrical supplier.WARNING:Do not cut, remove or break the ground terminal. Do not try to fit a three terminal plug into a receptacle or connector body that does not fit the plug. If the receptacle or connector body does not fit the plug, see your authorized dealer to get an authorized person to make the connection.WARNING:Do not move the machine over an electrical cord. Always lift the cord over the machine.EXTENSION CORDSUse only an approved extension cord with three conduc-tors, a plug with three terminals and a connector body with three holes. This machine has a power cord with wire size 18 AWG (AWG means American Wire Gauge).WARNING:If you use an extension cord,use an extension cord with minimum wire size 16 AWG.Figure 9Plate ScrewOutlet must be connected to the electrical ground(B)(A)Ground PinGround TabAdapter(C)NOTE: Do not use adapters shown in figures B and C in Canada.Figure 10How to Check the Commutator and the Carbon BrushesTo check the commutator and the carbon brushes, followthis procedure:1.Remove the screws that hold the motor cover andremove the cover.2.Remove the spring clips that hold the top of thevacuum motor and remove the top of the vacuummotor.3.Inspect the commutator. Take the machine to anauthorized repair location if you see any of the followingconditions.a.Small holes in the surface of the commutator.See figure 10A.b.Uneven color - Look for an even dark brown color.Clean areas or very dark areas indicate a problem.See figure 10B.c.High mica - The mica insulation must be lowerthan the commutator bars. See figure 10C.4.Remove the carbon brush assemblies and check thecarbon brushes. Replace both carbon brush assem-blies if either carbon brush is shorter that 1 cm (3/8inch). If either brush is shorter than 13 mm (1/2 inch),order replacement brushes. Be ready to replace bothcarbon brushes earlier than the normal inspectiontime.5.Install the top of the motor, the motor cover, and thefasteners.WARNING:The machine must be tested forelectrical safety after electricalrepairs are made.NOTE: For the best operation, have the machine checkedby an authorized repair person every 12 months. Forsafe operation and longer life of your machine, use onlygenuine Clarke Technology replacement parts.Circuit BreakerIn case of a motor overload due to a foreign object in theroller brush or impeller, the overload circuit breaker turnsoff the motor. After removal of the foreign object, the motorcan be restarted by pressing the button on the bottom of theunit.Clarke Technology Operator's Manual Model 560 B Page -7-CLARKE TECHNOLOGY Model 560BAssembly Drawing 3/995051Page -8- Clarke Technology Operator's Manual Model 560 BClarke Technology Operator's Manual Model 560 B Page -9-130037A Cover 1251600ABumper 13920688Nut, Plastic 1456205A Nut, M7 Left 1587608A Washer 1654711A Impeller 17964037Screw 4858546A Spacer1951910A Clamp, Strap 21052958A Chamber, Fan 11157878A Mount, Rubber 212961025Screw, Wing 213964007Screw, 6 x 12214980607Washer81554801A Housing, Blower 11658008A Screw, 4 x 8217980603Washer 218667201Retainer 11954304A Gasket 120912311Switch121964048Screw, 4 x 182********Insulation, Switch 12354802A Plate, Bottom 12454379A Gasket12556806A Plate, Sealing 12653010A Ring Retainer 127980933Washer 128961021Screw 12954302A Gasket130666612Nozzle Plate 131980935Washer Spring 232662004Lever233961027Shoulder Screw 23442217A Power Cord 135964006Screw, 3 x 16436912313Terminal Block 13754701A Insulation 13857318A Strain Relief 13957303A Rivet, Plastic 14058601A Spring 141924003Nut M614256808AFoot Pedal1Ref.No.Description Part No.Part No.Ref.No. No.Req’d. No.Req’d.Description 4356807A Foot Plate 14456810A Roll Pin14556809B Pivot, Handle 146961022Screw147668101Strain Relief 14844708B Motor14950295A Carbon Brush 250662005Clamp15153167A Insulating Disc 15258327A Shaft, Belt15351994A Circuit Breaker 15459905A Wheel 455660502Axle45651924A Clip, Locking 45752704A Cover, Hinged 158661507Cap, Brush End 159663602Thread, Guard 160902648Bearing26151406A Brush Segment 462964047Screw, 4 X 12863660905Brush Assembly 164663703Handle Grip165663906Handle Tube, Upp 166664506Cable Guide 167924004Nut M5268664507Cable Guide 169662104Bag Clip170964004Screw, 5 x 16271668310Spring172964062Screw, 8 x 25273662411Connector 174662412Connector 175662001Dustbag Clip 176660603Paper Filter Bag 177662801Elbow 178664102Hose179663909Handle Tube Low 180660609Cloth Filter Bag 181663409Gasket 182660201Adaptor 183903404Belt18454803AHousing Asm.1CAUTION:Repairs by qualified personnel only.ACHTUNG: Reparaturen nur durch Facharbeiter.PRECAUTION: Reparations par personnel specialize seulement.PRECAUTUION: Unicamente personal calificado deberian hacer reparaciones.CLARKE TECHNOLOGY Model 560BParts List 3/99NOTESALTO® PRODUCT SUPPORT BRANCHESALTO Danmark A/S, AalborgBlytaekkervej 2DK-9000 Aalborg+45 72 18 21 00ALTO Danmark A/S, HadsundIndustrikvarteretDK-9560 Hadsund+45 72 18 21 00ALTO Canada Ltd., Rexdale Ontario24 Constellation Ct.(416) 675-5830ALTO Overseas Inc., Sydney (Australia)1B/8 Resolution DriveCaringbah NSW 2229+61 2 9524 6122AL TO Cleaning Systems Asia Pte Ltd., SingaporeNo. 17 Link RoadSingapore 619034+65 268 1006ALTO Deutschland GmbH, Frondenberg (Germany)Ardeyer Str. 15D-58730 Frondenberg+49 2373 754 200AL TO Cleaning Systems (UK) Ltd., PenrithGilwilly Industrial EstatePenrithCumbria CA11 9BN+44 1768 868 995ALTO France S.A. StrasbourgB.P. 44, 4 Place d’OstwaldF-67036 StrasbourgCedex 2+33 3 8828 8400ALTO Nederland B.V. VianenStuartweg 4CNL-4131 NJ Vianen+31 347 324000ALTO Sverige AB, Molndal (Sweden)Aminogatan 18Box 4029S-431 04 Molndal+46 31 706 73 00ALTO Norge A/S, Oslo (Norway)Bjornerudveien 24N-1266+47 2275 1770CLARKE TECHNOLOGYAMERICAN SANDERS TECHNOLOGYA.L. COOK TECHNOLOGYCustomer Service Headquarters and Factory2100 Highway 265Springdale, Arkansas 72764(501) 750-1000Technical Service1-800-356-7274U. S. A. LocationsEuropean LocationsALTO U.S. Inc., St. Louis, Missouri16253 Swingley Ridge Road, Suite 200Chesterfield, Missouri 63017-1725ALTO U.S. Inc., Springdale, Arkansas2100 Highway 265Springdale, Arkansas 72764(501) 750-1000Customer Service - 1-800-253-0367Technical Service - 1-800-356-7274ALTO U.S. Inc., Bowling Green, Ohio 434021100 HaskinsALTO U.S. Inc., Clearwater, Florida 337651500 N. Belcher RoadALTO U.S. Inc., Carlstadt, New Jersey 07072150 Commerce Road(201) 460-4774ALTO U.S. Inc., Elk Grove, Illinois 600072280 Elmhurst Road(847) 956-7900ALTO U.S. Inc., Denver, Colorado 802041955 West 13th Ave.(303) 623-4367ALTO U.S. Inc., Houston, Texas 770407215 North Gessner RoadALTO U.S. Inc., Madison Heights, Michigan 48071-015829815 John R.(810) 544-6300ALTO U.S. Inc., Marietta, Georgia 300621355 West Oak Common Lane(770) 973-5225CLARKE TECHNOLOGY WARRANTYThis Clarke Technology Industrial/Commercial Floor Product is warranted to be free from defects in materials and workmanship under normal use and service for a period of one year from the date of purchase, when operated and maintained in accordance with Clarke T echnology's Maintenance and Operations instructions.This warranty is extended only to the original purchaser for use of the product. It does not cover normal wear parts such as electrical cable, rubber parts, hoses and motor brushes.If difficulty develops with the product, you should:(a).Contact the nearest authorized Clarke Technology repair location or contact the Clarke Technology Service Operations Department, 2100 Highway 265, Springdale, Arkansas 72764, for the nearest authorized Clarke T ech-nology repair location. Only these locations are authorized to make repairs to the product under this warranty.(b).Return the product to the nearest Clarke Technology repair location. T ransportation charges to and from the repair location must be prepaid by the purchaser.(c).Clarke Technology will repair the product and or replace any defective parts without charge within a reason-able time after receipt of the product.Clarke T echnology's liability under this warranty is limited to repair of the product and/or replacement of parts and is given to purchaser in lieu of all other remedies, including INCIDENT AL AND CONSEQUENTIAL DAM-AGES.THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE SPECIFIED HEREIN. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION OF THE FACE HEREOF. NO WARRANTIES, INCLUDING BUT NOT LIMITED TO WARRANTY OF MECHANT ABILITY, SHALL BE IMPLIED. A warranty registration card is provided with your Clarke T echnology product. Return the card to assist Clarke T echnology in providing the performance you expect from your new floor machine.ALTO, 2100 Highway 265, Springdale, Arkansas 72764.CLARKE TECHNOLOGY reserves the right to makechanges or improvements to its machine without notice.Always use genuine Clarke Technology Parts for repair.CLARKE TECHNOLOGY2100 Highway 265Springdale, Arkansas, 72764。

PMC-560说明书V4.0

PMC-560说明书V4.0

PMC-560型电力监控智能装置说明书(V4.0版)制定:审核:批准:HD-HDW-011-H00012004-10-25第一章简介1.1功能介绍高性能的电力监控智能装置PMC-560是一种数字式三相电力监控智能装置,直接针对一回线路设计,能够完成一回线路的“三遥”功能,广泛用于工业、商业、民用电力系统的变电站中。

PMC-560具有较高的性价比,集电能监测、分析、控制等功能于一体,符合分布式要求,可直接取代常规电力监控装置、变送器、测量仪表、RTU、事故记录和报警装置、谐波分析仪、故障录波仪和电能质量分析仪等。

PMC-560以12MHz、16位微处理器为核心,处理速度高,能够完成复杂的实时处理工作,既能单独完成电力监控任务,又能作为一个多功能的RTU工作于一个大型电力监控网络中。

表1.1PMC-560基本功能输入和输出PMC-560适用于各种星形、三角形电力系统。

电压接线方式包括四线星形接线、三线星形接线、三线三角形接线。

另外,PMC-560还具有一路IN电流输入,可用来测量中性线电流或零序电流,它的高速越限系统可提供可靠的接地故障报警。

PT二次侧的三相交流电压可以直接接入PMC-560的电压输入端;CT二次侧的三相交流电流可以直接接入PMC-560的电流输入端,对于只有两相CT的情况,可以通过接线来得出另一相的电流。

另外,PMC-560还提供了电压输入额定为220V的配置,主要用于220/380VAC的星形系统直接接入。

PMC-560的电流输入额定有5A和1A两种配置,分别适应于CT二次侧电流为5A和1A的情况。

PMC-560带有一路模拟量输入AI,通过选用不同的配置而具有不同的测量功能,如变压器温度、电池电压、PT开口三角电压(3U0)等。

12路开关量输入可用来监测断路器的状态、隔离开关的状态、继电保护动作或其他外部接点的状态,其中四路还可用作脉冲计数器,来测量电机转速、电能脉冲个数等。

基本型号的PMC-560内部有24V直流电源提供自激,用于无源触点监视;对于有源接点,可选择外部激励配置(-EES选项)的PMC-560。

AuteX5612E 5608 无线控制器说明书

AuteX5612E 5608 无线控制器说明书
Modifying the device not authorized by Beijing Autelan Technology Co.,Ltd may result in the equipment no longer meeting FCC requirements for Class A devices. Therefore, your right to use the equipment may be impaired by FCC regulations, and you may be required to remove any interference to radio or television communications at your own expense.
1.1 简介 ................................................................................................................................................1-1 1.2 产品型号.........................................................................................................................................1-1 1.3 产品规格.........................................................................................................................................1-1 2 产品硬件结构 ................................................................................................................................... 2-1

PMC-560说明书V4

PMC-560说明书V4

. . ..PMC-560型电力监控智能装置说明书(V4.0 版)制定:审核:批准:HD-HDW-011-H0001 2004-10-25第一章简介1.1 功能介绍高性能的电力监控智能装置PMC-560是一种数字式三相电力监控智能装置,直接针对一回线路设计,能够完成一回线路的“三遥”功能,广泛用于工业、商业、民用电力系统的变电站中。

PMC-560具有较高的性价比,集电能监测、分析、控制等功能于一体,符合分布式要求,可直接取代常规电力监控装置、变送器、测量仪表、RTU、事故记录和报警装置、谐波分析仪、故障录波仪和电能质量分析仪等。

PMC-560以12MHz、16位微处理器为核心,处理速度高,能够完成复杂的实时处理工作,既能单独完成电力监控任务,又能作为一个多功能的RTU工作于一个大型电力监控网络中。

表1.1 PMC-560基本功能输入和输出PMC-560适用于各种星形、三角形电力系统。

电压接线方式包括四线星形接线、三线星形接线、三线三角形接线。

另外,PMC-560还具有一路IN电流输入,可用来测量中性线电流或零序电流,它的高速越限系统可提供可靠的接地故障报警。

PT二次侧的三相交流电压可以直接接入PMC-560的电压输入端;CT二次侧的三相交流电流可以直接接入PMC-560的电流输入端,对于只有两相CT的情况,可以通过接线来得出另一相的电流。

另外,PMC-560还提供了电压输入额定为220V 的配置,主要用于220/380VAC的星形系统直接接入。

PMC-560的电流输入额定有5A和1A两种配置,分别适应于CT二次侧电流为5A和1A的情况。

PMC-560带有一路模拟量输入AI,通过选用不同的配置而具有不同的测量功能,如变压器温度、电池电压、PT开口三角电压(3U0)等。

12路开关量输入可用来监测断路器的状态、隔离开关的状态、继电保护动作或其他外部接点的状态,其中四路还可用作脉冲计数器,来测量电机转速、电能脉冲个数等。

日业BM560X CM560系列起重专用变频器用户手册V2.0

日业BM560X CM560系列起重专用变频器用户手册V2.0
第七章 参数说明............................................................................................................................................................. 67
7.1 F0 组基本功能组.................................................................................................................................................. 67 7.2 F1 组启停控制...................................................................................................................................................... 72 7.3 F2 组 V/F 控制参数..............................................................................................................................................75 7.4 F3 组矢量控制参数.............................................................................................................................................. 77 7.5 F4 组电机参数...................................................................................................................................................... 79 7.6 F5 组输入端子...................................................................................................................................................... 80 7.7 F6 组输出端子...................................................................................................................................................... 85 7.8 F7 组 辅助功能及人机界面功能....................................................................................................................... 86 7.9 F8 组通信功能...................................................................................................................................................... 93 7.10 F9 组故障与保护................................................................................................................................................ 94 7.11 FA 组过程控制 PID 功能...................................................................................................................................96 7.12 FB 组摆频功能....................................................................................................................................................98 7.13 FC 组多段速功能及简易 PLC 功能................................................................................................................. 99 7.14 FD 组(保留)................................................................................................................................................. 103 7.15 FE 组 增强组....................................................................................................................................................104 7.15 FF 组 厂家参数组............................................................................................................................................104

电动执行器操作手册

电动执行器操作手册
单相执行器EWS,E10WS,E110WS和E10WS •使用状况.................................................................................................................17 •标准设备.................................................................................................................17 •法兰和轴套.............................................................................................................17 •选配件.................................................................................................................18 •技术参数.................................................................................................................18 •附加技术参数.........................................................................................................19 •E65WS-E160WS标准接线图..................................................................................20 •P.C.B视图和接线连接视图.................................................................................21 •接头表格.................................................................................................................22

PMC-560说明书V4

PMC-560说明书V4

.PMC-560型电力监控智能装置说明书(V4.0 版)制定:审核:批准:HD-HDW-011-H0001 2004-10-25第一章简介1.1 功能介绍高性能的电力监控智能装置PMC-560是一种数字式三相电力监控智能装置,直接针对一回线路设计,能够完成一回线路的“三遥”功能,广泛用于工业、商业、民用电力系统的变电站中。

PMC-560具有较高的性价比,集电能监测、分析、控制等功能于一体,符合分布式要求,可直接取代常规电力监控装置、变送器、测量仪表、RTU、事故记录和报警装置、谐波分析仪、故障录波仪和电能质量分析仪等。

PMC-560以12MHz、16位微处理器为核心,处理速度高,能够完成复杂的实时处理工作,既能单独完成电力监控任务,又能作为一个多功能的RTU工作于一个大型电力监控网络中。

表1.1 PMC-560基本功能输入和输出PMC-560适用于各种星形、三角形电力系统。

电压接线方式包括四线星形接线、三线星形接线、三线三角形接线。

另外,PMC-560还具有一路IN电流输入,可用来测量中性线电流或零序电流,它的高速越限系统可提供可靠的接地故障报警。

PT二次侧的三相交流电压可以直接接入PMC-560的电压输入端;CT二次侧的三相交流电流可以直接接入PMC-560的电流输入端,对于只有两相CT的情况,可以通过接线来得出另一相的电流。

另外,PMC-560还提供了电压输入额定为220V 的配置,主要用于220/380VAC的星形系统直接接入。

PMC-560的电流输入额定有5A和1A两种配置,分别适应于CT二次侧电流为5A和1A的情况。

PMC-560带有一路模拟量输入AI,通过选用不同的配置而具有不同的测量功能,如变压器温度、电池电压、PT开口三角电压(3U0)等。

12路开关量输入可用来监测断路器的状态、隔离开关的状态、继电保护动作或其他外部接点的状态,其中四路还可用作脉冲计数器,来测量电机转速、电能脉冲个数等。

ELWA 光伏热水器装配与操作手册说明书

ELWA 光伏热水器装配与操作手册说明书

ELWA®Photovoltaic Water HeaterAssembly- and Operation ManualIntended UseThe electric hot water device ELWA is designed to be used with photovoltaic arrays up to2.5 kWp nominal power.ELWA should be mounted on conventional hot water tanks or storage tanks with a minimum capacity of about 150 litres.The device does not feed any power to the grid. A permission of the grid operator or the utility is NOT required.Any use different from that described above may lead to damage and can even cause short circuits, electric shocks or fire. Safety instructions of this manual must be followed strictly! The device fulfils national and European regulations. Company and product name are trademarks of my-PV GmbH. All rights reserved.Scope of Supply∙Photovoltaic Water Heater ELWA∙IP21 Cover∙ 1 set MC4 Connectors∙Assembly- and Operation ManualAlways comply with local regulations for mounting and connection.Any damage caused by ignoring the installation and user manual is not covered by the manufacturer´s warranty.Permanent equipotential bonding of the device and the storage tank is mandatory.Never switch on the device if the heating rod is not fully immersed.The device is intended for use in a dry environment, the enclosure must not get wet or moist. Danger of electric shock!Never use the device where ammonia is present.Never use the device in a dusty environment.Never cover the ventilation holes of the enclosure.Always mind the mounting position: heating rod horizontal, power cord bottomAvoid high (>40°C) and low (<5°C) ambient temperatures during storage and operation of the device. Avoid direct sunlight.Never exceed the maximum DC input voltage (360V).The thermal fuse blows at approx. 100°C and deactivates the device permanently.Caution when using in unpressurized tanks!AC supply must be fused 10 to 16A.In commercial facilities electrical installations have to comply with all local regulations. Exemption of Warranty and LiabilityAny warranty or liability is exempted for:∙Injury to persons and/or damage to property caused by unintended use or in disregard of safety- and user instructions∙Consequential damage∙Unauthorized modification, disassembling or other conversion of the device∙Damage caused by calcium deposits on heating element.∙Damage caused by corrosion at heating element.Assembly and Installation InstructionsThe installation of the device must only be carried out by authorized technical staff.The storage tank must be drained properly.ELWA is intended for horizontal mounting in hot water or storage tanks with 1 ½ inch standard female threads.The unheated section of the heating rod is 100mm from sealing face, the length of the thread pipe must not exceed 90mm.Use the pre-assembled O-ring seal supplied. Do not use any grease or lubrication agents. The plastic thread must not be sealed with the help of hemp or other sealing material.If an adapter flange is used on the tank, we recommend a flange plate made of stainless steel or at least of an enamelled material. Otherwise corrosion could occur on the heating elements, but this is excluded from the warranty.Do not apply force when screwing in the entire device until the seal is slightly pressed. Make sure that the O-ring is properly placed in its groove. Then tighten the heating rod with a 60mm spanner. Never exceed a torque of 50 Nm.If the device is not upright (power cord bottom) after the thread has been tightened, it can be turned gently left or right.Then tighten the 4 lock nuts to fix the device:Make sure that the heating rod is fully immersed when filling the water tank. Check for leakage.1.Earth (ground) the storage tank according to local regulations.2.Connect Earth (ground) wire to the grounding screw of the device with a minimum wiresection of 1.5mm² (AWG15). Test the ground conductor resistance according to the local regulations (Protection Class 1):M4 Cable Lug3.Make sure that the device is switched off.4.Connect MC4 DC wires with correct polarity. Wrong polarity does not cause any damage,but the device will not work.5.Connect AC plug if boost backup heating is desired.1.Earth (ground) the storage tank according to local regulations.2.Connect Earth (ground) wire to the grounding screws of both devices with a minimum wiresection of 1.5mm² (AWG15). Test the ground conductor resistance according to the local regulations (Protection Class 1) (see above).3.Make sure that both devices are switched off.4.5. but the device will not work.6.Connect AC plug of the upper ELWA if boost backup heating is desired.Controls and IndicatorsMain switchRotary knob and indicatorsMC4 Rotary knob for temperature adjustmentLED green Target temperature reached LED yellow Normal operation LED red ErrorBoth ELWAs are connected in parallel!MC4 Y-connectors not supplied.Operating Status IndicatorStartup (~ 7 sec)StandbyHeating from DCBoost- BackupHeating finished, target temperature reachedSetup Mode (see p 5,6)Error (see p 6)Legend:LED onLED flashing LED offStart-upNormal operation without boost backup (AC plug not connected)Remark: It takes several minutes to start-up ELWA after connecting the DC. The green LED flashes (Standby). 1. Adjust desired solar target temperature2. Switch on main switch (Device starts operating several minutes after the DC has been connected and solar power is available)3. Device returns to normal operation ◆ LED yellow on4.If target temperature reached ◆ Device switches off, LED green onNormal operation with boost backup (AC plug connected)Boost backup ensures reaching the AC target temperature in the afternoon independently of sun power.for private applications. For commercial use, especially year-round operation, please contact my-PV.AC target temperature is factory preset to 50°C. See next chapter to change.The next boost backup cycle starts in the afternoon of the next day. If a manual reheat isrequired (e.g. in the evening), simply switch the device off and on again. This activates the boost backup cycle.Remark: If you first connect DC it takes several minutes to start-up the device (LED green flashing) 1. Set rotary knob to desired solar target temperature2.Switch on main switch (Device starts operating several minutes after the DC has been connected and solar power is available)3.Device returns to normal operation ◆ LED yellow on if solar powered,◆ LED yellow flashes if backup powered4.If target temperature reached ◆ Device switches off, LED green on Adjusting the boost backup target temperature(factory preset to 50 °C)1.Switch off main switch2.Adjust rotary kn op to …spanner“ position (far left)3.Switch on main switch ◆ all 3 LEDs flash (Setup Mode)4.Set rotary knob to desired reheat temperature◆ LEDs flash alternately red/green and yellow5.Switch off main switch ◆ backup temperature is saved6.Set rotary knob to desired solar target temperature7.Switch on main switch ◆ Device returns to normal operationStratification Charge with two ELWAsELWA is factory preset to operate as a single device or as an upper device in stratification charge mode.The lower ELWA has to be set as follows:1.Switch off main switch2.Adjust rotary knop to …spanner“ position (far left)3.Switch on main switch ◆all 3 LEDs flash (Setup Mode)4.Adjust rotary knop to position◆LEDs run from top to bottom5.Switch off main switch ◆Setting is saved6.Set rotary knob to desired solar target temperature7.Switch on main switch ◆Device is in standby mode (green LED flashing) untilactivated by upper deviceThis setting can be reversed by following the above procedure by setting to symbol.Error DisplaysThe red LED indicates different error conditions by flashing:1x flash ◆Over temperature fuse blown. Call your installer for service.2x flash ◆Water temperature above 90°C. Device stops and will restart heating when the temperature has fallen.Note: The water temperature is close to the over temperature fuse threshold. IFthe water has been heated by external heat sources, adjust the maximumtemperature threshold of this source to 90°C.3x flash ◆Electronic circuit over temperature. Device switches off and restarts after cool-down.4x flash ◆Error of the electronic circuit or the heating rod. Call your installer for service.5x flash ◆DC isolation fault (either solar array or heating rod). Call your installer for service. 6x flash ◆Temperature sensor fault. Call your installer for service.MaintenanceUse in limy water can lead to lime scale deposition at the heating rod especially of the target temperature is set above 60°C. We recommend an annual check. Dismantle device from storage tank and remove lime deposition. Never scratch the heating rod surface (corrosion might arise).TroubleshootingThe device does not contain any user serviceable parts. Call your installer for service. DisposalKeep packaging box or dispose properly.Dispose the device according to legal regulations at the end of lifetime.EU Declaration of ConformityYou can find them at any time on Technical DataDC ACDC-voltage 100 - 360 V (max.) Heating power see nameplateMPP-range 100 - 360 V Powerconnection Single phase, grounded plug, 230 V, 50-60 HzNumber of MPP trackers 1 Recommendedfuse10 – 16 AMax. input current 10 A, internally limited Power cord 2,7 mNominal power 2,000 W at 25°C ambienttemperature, derating atoverheat Standby-powerconsumption0 W at DC operation, <2 W atAC operationDC inputs Original MC4, 1 string MPP- efficiency 99,8 %General DataOperating pressure max. 10 bar (1MPa) Overall efficiency >99% at nominal power Protection class IP20(IP21 with Cover) Operatingtemperature range5 °C to 40 °C Operating display 3 LED’sInterface Serial IR InterfaceDimensions (WxHxD) 130 x 180 x 600 mm incl. heating rodHeating rod length 45 cmHeating rod thread 1 ½ inchWeight 2 kg with power cord,without carton Subject to change.my-PV GmbHTeichstrasse 43, 4523 Neuzeug 。

PMC-560说明书V4.0

PMC-560说明书V4.0

PMC-560型电力监控智能装置说明书(V4.0版)制定:审核:批准:HD-HDW-011-H00012004-10-25第一章简介1.1功能介绍高性能的电力监控智能装置PMC-560是一种数字式三相电力监控智能装置,直接针对一回线路设计,能够完成一回线路的“三遥”功能,广泛用于工业、商业、民用电力系统的变电站中。

PMC-560具有较高的性价比,集电能监测、分析、控制等功能于一体,符合分布式要求,可直接取代常规电力监控装置、变送器、测量仪表、RTU、事故记录和报警装置、谐波分析仪、故障录波仪和电能质量分析仪等。

PMC-560以12MHz、16位微处理器为核心,处理速度高,能够完成复杂的实时处理工作,既能单独完成电力监控任务,又能作为一个多功能的RTU工作于一个大型电力监控网络中。

表1.1PMC-560基本功能输入和输出PMC-560适用于各种星形、三角形电力系统。

电压接线方式包括四线星形接线、三线星形接线、三线三角形接线。

另外,PMC-560还具有一路IN 电流输入,可用来测量中性线电流或零序电流,它的高速越限系统可提供可靠的接地故障报警。

PT二次侧的三相交流电压可以直接接入PMC-560的电压输入端;CT二次侧的三相交流电流可以直接接入PMC-560的电流输入端,对于只有两相CT的情况,可以通过接线来得出另一相的电流。

另外,PMC-560还提供了电压输入额定为220V的配置,主要用于220/380VAC的星形系统直接接入。

PMC-560的电流输入额定有5A和1A两种配置,分别适应于CT 二次侧电流为5A和1A的情况。

PMC-560带有一路模拟量输入AI,通过选用不同的配置而具有不同的测量功能,如变压器温度、电池电压、PT开口三角电压(3U0)等。

12路开关量输入可用来监测断路器的状态、隔离开关的状态、继电保护动作或其他外部接点的状态,其中四路还可用作脉冲计数器,来测量电机转速、电能脉冲个数等。

惠而浦 WED560LHW 烘干机通风规格 说明书

惠而浦 WED560LHW 烘干机通风规格 说明书

W11222085ATable of ContentsDRYER VENTING SPECIFICATIONSDRYER SAFETYDRYER SAFETY ..............................................................................1OUTSIDE EXHAUST REQUIREMENTS ........................................4EXHAUST SYSTEM REQUIREMENTS - GENERAL ....................4SINGLE DRYER VENTING SYSTEMS ..........................................4Dryer Airflow .................................................................................4Codes Agency Approvals ............................................................5Additional Elbows.........................................................................5Use of Oval shaped Duct to Exhaust Clothes Dryers .................5Alternate Duct Sizes .....................................................................5Use of PVC Pipe/Tube .................................................................5Booster Fans ................................................................................53rd Party Venting Accessories .......................................................5Dryer Closet Installations .............................................................5“AF” Code ....................................................................................6Measuring and Verifying Actual System Back Pressure .............6Maximum Allowable Back Pressure for Dryer .............................6MUL TIPLE DRYER VENTING SYSTEMS ......................................6Option 1 - Horizontal System ......................................................7Option 2 - Vertical System ...........................................................7Option 3 - Combination System ..................................................7DRYER INSPECTION AND CLEANING . (7)■If you are installing a gas dryer, it is recommended that the owner post, in a prominent location, instructions for the customer’s use in the event the customer smells gas. This information should be obtained from your local gas supplier.Post the following warning in a prominent location.234OUTSIDE EXHAUST REQUIREMENTSThe five basic reasons for exhausting a dryer outdoors are detailed in this section:1. To meet codes requirements.2. To remove moisture from laundry area.3. To avoid lint accumulation in laundry area.4. To remove excess heat from laundry area.5. To expel exhaust gases for gas fueled dryers.Codes RequirementsThe following codes should be reviewed to ensure dryer vent systems are in compliance:1. International Mechanical Code (sections related to dryerventing).2. National Fuel Gas Code.3. UL 2158 Electric Clothes Dryer Standard references ventingrequirements.4. ANSI Z21.5.1 - Gas Clothes Dryers (sections related to dryerventing).5. Other sections of these codes (regional and local) may alsoapply to multi-dryer vent systems.There are other codes requiring dryers to be exhausted when installed in confined spaces where specified clearances from combustible surfaces cannot be met. See the InstallationInstructions for the specific dryer model being used or considered for spacing requirements.Local codes and ordinances that exist must also be met. Consult your local building inspector for more information.EXHAUST SYSTEM REQUIREMENTS - GENERALVenting systems for Whirlpool dryers must meet the following requirements:■The capacity to handle up to 230 CFM (cubic feet per minute) of air flow for each dryer in the system.■ A minimum back pressure of -0.1" (-2.5 mm) water column (vacuum) when measured at the connection to the dryer.■Provide minimal back pressure, based on the maximum rated vent length shown in the Installation Instructions included with dryer. Maximum Allowable Back Pressure chart (pg. 6) lists maximum rated vent length and back pressure.■The minimum duct air velocity during normal operatingconditions should be at least 1,200 FPM (feet per minute) to keep lint moving through the vent. (In a 4" (102 mm) diameter pipe, this requires at least 105 CFM of air flow.)SINGLE DRYER VENTINGSYSTEMSSingle dryer venting systems are defined as systems that have only one dryer unit attached to a residential-type 4" (102 mm) diameter rigid metal vent system. For single dryer venting systems, see the Installation Instructions for the specific dryer model being used or considered to determine the allowable length and number of elbows for the venting system.Dryer AirflowThe airflow of a dryer depends on the design of the exhaust vent. Each dryer model has a maximum rated vent length, shown in the product literature that is supplied with each model, or on the website. The exhaust airflow of any Whirlpool produced dryer at the maximum rated vent length is at least 105 CFM. The maximum airflow is 230 CFM. This includes standardvent and long vent dryer models.WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.NOTE: This guide is intended to aid licensed HVAC orArchitectural Engineers who design single and multi-dryer unit venting systems for Whirlpool Corporation dryers sold in the United States. Whirlpool Corporation provides required airflow and back pressure specifications, measured at the connection between the vent system and the dryer’s vent pipe, for use in the design of dryer vent systems. Whirlpool does not design multi-dryer vent systems, nor does Whirlpool review or provide approvals for vent systems designed by third-party engineering firms.MoistureExhausting moisture into the room can also cause damage to walls, floors, picture hangers, and cause condensation on windows and walls in cold weather.LintEven though the dryer is equipped with a lint screen, fine particles of lint will pass through the screen and be exhausted out of the dryer. Proper venting of the dryer will minimize lint accumulation in the laundry area.HeatIn order to remove moisture from the garments in the dryer, heat is generated to vaporize the water. Exhausting the dryer outdoors avoids the buildup of excess heat from the laundry area of the building.Exhaust Gases (Gas Fueled Dryers only)Combustion exhaust gases must be vented outdoors.5Use of Oval shaped Duct to Exhaust Clothes DryersThe use of oval-shaped ducting, where a 4" (102 mm) diameter smooth round duct is compressed in one dir ection to fit inside a 2x4 construction wall is acceptable for all dryers produced by Whirlpool Corp. The smallest allowable dimension across the outside of the oval is 31/8" (79.3 mm). The transition to this oval from the dryer duct requires a clamp to hold the oval shape of both parts and provide a good seal.See the table below for the required vent length reduction, which depends on the total length of oval venting used.Reference the product's Installation Instructions, for dryer model to be installed, for the rated dryer vent system lengths and for additional venting requirements and warnings.Dryer Vent Length Reduction Requirements for Oval VentingTotal length of oval vent duct in the vent system (including all duct pieces, elbows and transitions that are oval inshape)Required reduction in totalvent system length1-20 ft (0.30 m-6.0 m) of ovalvent duct No reduction required 21-40 ft (6.4 m-12.1 m) of ovalvent duct Reduce by 10 ft (3.0 m)41-60 ft (12.4 m-18.2 m) ofoval vent duct Reduce by 20 ft (6.0 m)61-80 ft (18.5 m-24.3 m) ofoval vent ductReduce by 30 ft (9.1 m)Codes Agency ApprovalsAll Whirlpool electric dryer models, including “long vent dryers,” Turbo Vent™ dryers and combo washer/dryer units that are sold in the United States and Canada are UL listed (reference UL 2158 standard), and all Whirlpool gas dryer models are UL or CSAlisted (reference ANSI Z21.5.1 standard). These standards require testing at the maximum-rated exhaust vent conditions that are published in the product literature for each individual model. The designation for the UL or CSA listing can be found on or adjacent to the serial label on the product.Additional ElbowsIn cases in which the Installation Instructions do not address the vent length for the specific number of elbows required for a particular application, the following calculations may be used. (The total vent system length includes all straight and curved portions of the vent system.):■For 90° elbows, reduce the allowable vent system length by 10 ft (3.05 m).■For 45° elbows, reduce the allowable vent system length by 6 ft (1.83 m).For example, if the Installation Instructions state that a dryer is allowed 40 ft (12.2 m) of total vent length with two 90° bends, and the installation requires three 90° bends, the total allowable vent length would be reduced by 10 ft (3.0 m) (from 40 ft [12.2 m] to 30 ft [9.1 m]).Alternate Duct SizesAs the duct size is increased from 4" (102 mm), the duct has a larger cross-sectional area than the recommended duct. Using an identical blower system, increasing the duct size beyond 4" (102 mm) will decrease the airflow speed (velocity) inside the exhaust pipe, which then reduces the ability of the air stream to keep lint suspended and moving with the air through the duct. Although the volume of flow in CFM (cubic feet per minute) might be high, due to the lower duct restriction of the larger size duct, the actual speed (velocity) of the air is what moves lint through the exhaust pipe. Although there may be some local codes that allow these alternate vent sizes, Whirlpool doesn't approve of the use of anything other than rigid metal or flexible metal duct in a 4" (102 mm) diameter. Use of PVC Pipe/TubeOne of the potential problems with PVC pipe is that the material in the pipe wall doesn't retain heat as well as metal and condensation can occur more easily inside of the PVC pipe (from the moisture removed from the clothes). When there is condensation left in the pipe, lint may stick to the walls and collect, which can eventually lead to a severely restricted or blocked vent. Although there may some local codes that allow these alternate vent designs, Whirlpool doesn't approve of the use of anything other than rigid metal or flexible metal duct in a 4" (102 mm) diameter.Booster FansCurrently, there is no UL classification for booster fans and their direct connection to dryers (to ensure that the dryer won't run if the booster fan fails), so Whirlpool does not provide recommendations for booster fan use.3rd Party Venting AccessoriesWhirlpool does not provide approvals for 3rd party ventaccessories that are not licensed by Whirlpool Corporation.Dryer Closet InstallationsClosets used for dryer installation must provide multiple openings to allow air to flow through the dryer and around the dryer to dissipate heat. Any dryer enclosure or room that does not have an inlet and outlet for an operating forced air HVAC system isconsidered a closet, and requires room venting. The room venting can be installed into the walls of the dryer enclosure, as well as the door, provided it will not be blocked after the dryer is installed. Refer to the product literature for minimum clearances between the product and the enclosure surfaces. Refer to ANSI Z21.5.1 section 2.14.1.Recommended room venting and spacing for non-stacked installations*Required spacingA.Side view - closet or confined areaB.Closet door with vents6Certain electronic dryer models have airflow detectioncapabilities. (See specific model product literature for details). If the airflow in the dryer is extremely low, an “AF” code will be displayed on the control panel. For single dryer venting systems, this code means that you may have a blocked or partially blocked vent or that your overall vent system length is too long. To resolve this issue:■Check to see if the vent run from the dryer to the wall is crushed. Refer to the “Venting Requirements” section of the Use and Care Guide for more information.■Confirm that the vent run from the dryer to the wall is free of lint and debris.■Confirm that the exterior vent exhaust hood is free of lint and debris.■Confirm that your vent system falls within the recommended run length and number of elbows for the type of vent you are using. Refer to the “Plan Vent System” section of the Use and Care Guide for details.■Select a Timed Dry heated cycle, and restart the dryer.■If the message persists, have your entire home venting run cleaned.For multi-dryer venting systems, the “AF” code means that your vent may be blocked or partially blocked or that the venting system is creating back pressure in excess of the maximum allowed. In this case, the engineering firm that designed thesystem should be consulted.MULTIPLE DRYER VENTINGSYSTEMSMultiple dryer venting systems must be designed specifically for each application.NOTE: It is recommended that an architectural or HVACengineering firm be consulted for designing the dryer venting system.Connecting a number of dryers to a single vent system iscommon in coin-laundry stores and in many apartment buildings. Listed here are some requirements for examples of three different multiple dryer venting systems.The following guidelines should be considered in the design of any central exhaust system:■Exhaust individual dryers to the central exhaust duct system with proper size vents to assure adequate performance of each dryer. The dryer has round 4" (102 mm) exhaust duct connections. Connect each dryer to the central vent with a 4"(102 mm) diameter aluminum vent.■Install weighted dampers on each individual dryer exhaust duct. These dampers may be used for balancing out the overall duct system.■Design the central duct system for sufficient capacity tohandle the maximum number of dryers operated at one time.A.Dryer - empty and running on Air Only cycleB.12" (305 mm) min. of straight pipe - measure back pressure from the centerC.To vent systemD.Location on back pressure measurementE.Inclined manometerMaximum Allowable Back Pressure for DryerMaximum Rated Vent Length without 90° Elbows (determined fromproduct literature)Maximum AllowableBack pressure at connection to dryer (no clothes loadedand clean lint screen) 36-37 ft (10.9 m-11.2 m)0.40" (10.1 mm) Water Column 64 ft (19.5 m)0.60" (15.2 mm) Water Column 100 ft (30.4 m)0.80" (20.3 mm) Water Column 120 ft (36.5 m) 1.00" (25.4 mm) Water Column 130 ft (39.6 m)1.10" (27.9 mm) Water Column■Additional clearances might be required for wall, door, and floor moldings.■Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer.■For closet installation, with a door, minimum ventilation openings near the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.■The door louver openings for ventilation shown in the figure cannot be substituted with larger gaps between the bottom of the door and floor.■Companion appliance spacing should also be considered. Recommended room venting and installation spacing for recessed or closet installation, with stacked washer and dryer*Recommended spacing Measuring and Verifying Actual System Back Pressure Back pressure should be measured with an empty dryer, a clean lint screen and with the dryer operating in the Air Only cycle (no heat). Use an inclined manometer, such as Dwyer model 102 (0"-2" [0 mm - 51 mm] range) or Dwyer model 172(0"-1" [0 mm - 25 mm] range) to measure the Back Pressure. See the following illustration.7A. 4" (102 mm) diameter rigid metal back draft damper■Consider moisture, lint and air temperature in the design of the central duct system. Maximum exhaust temperature of the dryer will not exceed 200°F (93.3°C) when the dryer is operated according to the instructions provided with the dryer.■Provide for periodic inspection and clean-out of lint accumulated in the central duct system.Option 1 - Horizontal SystemThe most common is the horizontal system, in which banks of dryers are all located in one room and vented through a common duct. See the following illustration for an example of a generic *Minimum spacing required between dryers Option 2 - Vertical SystemThe vertical system is used in some apartment buildings that have a washer and dryer on each floor. Each dryer is exhausted into the same central vertical duct. See the following illustration for an example of a generic vertical system.Option 3 - Combination SystemThe combination system may be used in high-rise apartments, with a bank of dryers installed at several different levels. Each of these banks then exhausts into a central vertical vent. See the following illustration for an example of a combination system.A. Maximum back pressure measurement locationB. Weighted dampersC. Individual dryer exhaust - on each floorD. 0.1" (2.5 mm) water column maximum vacuumE. Main ductF . Barometric damper (use depends on exhaust system design)G. Source of outside air0.1" (2.5 mm) water column vacuum B. Weighted damper (each dryer)C. Maximum back pressure measurement locationD. Barometric damper (use depends on exhaust system design)E. Outside air sourceDRYER INSPECTION ANDCLEANINGFrequency of Exhaust SystemCleaningEvery exhaust system must be inspected periodically and cleaned to ensure that it is intact and free from lint accumulation. Thefrequency of these inspections will vary, depending on the system and usage of the dryer.■For single-family usage, an annual inspection is recommended.■In commercial usage or in multiple dryer systems, a more frequent inspection is recommended. Complaints oflong drying times or a hot dryer top indicate the need for inspection of the exhaust system.Inspecting the Exhaust System1. Disconnect the exhaust duct from the dryer and from theexhaust hood (at the exhaust outlet) outside of the building.2. Inspect the interior of the duct and remove any lintaccumulation.■Be sure that lint is removed from the exhaust hood (outlet). Lint may collect in the exhaust hood so that the flappers or louvers will not open or close completely.■After cleaning the exhaust hood, check that the flapper or louvers move freely.3. Reassemble the exhaust duct and hood, checking that thejoints are secure.4. Operate the dryer and verify that the exhaust air is notobstructed in the vent and that there are no leaks in the system.■Seal any leaks found.®/™ ©2018 Whirlpool. All rights reserved. Used under license in Canada.02/18Printed in U.S.A.W11222085A。

惠而浦 WED560LHW 规格说明书

惠而浦 WED560LHW 规格说明书

NOTE: Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.®/™ © 2020. All rights reserved. Printed in the U.S.A. D200104XXD. WED560LHSpecSheetV01.Total7.4 cu. ft.General Features & PropertiesIntuitive Controls Sanitize CycleAdvanced Moisture Sensing EcoBoost ™ Option Quad Baffles Closet-Depth Fit Laundry PedestalsAn American Company for Over 100 YearsElectrical DetailsHz 60Amps 30Volts240CertificationsADA CompliantYes ENERGY STAR ®CertifiedYesDrum Material Powder Coat Fuel Type Electric Door Style Side Swing Reversible Door Yes Number of Dryer Cycles36Selection of Drying CyclesBulky Items Colors Delicates Heavy Duty Normal Quick Dry Regular Sanitize Timed Dry Towels Whites Wrinkle Control Dryer Option SelectionsControl Lock Cycle Signal Damp Dry SignalEco Boost ™DimensionsProduct Dimensions (H x W x D)38-1/8" x 27" x 30-5/8"Depth with Door Open 90°54-5/16"Maximum Vent Length160'Venting Direction Right,Bottom, Rear VentlessNoReference MaterialInstall Guide Use & Care Guide WarrantyWhite WED560LHW7.4 cu. ft. Front Load Long Vent Electric DryerWED560LHWrinkle Shield ™ OptionHelp keep wrinkles from setting into clean, dry fabrics with the Wrinkle Shield ™ option. It keeps clothes tumbling for up to 150 minutes after the cycle ends or until you open the door.7.4 cu. ft. CapacityGet plenty of room to dry the large loads you washed in the matching front load washer. This 7.4 cu. ft. dryer easily handles bulky items like comforters and sleeping bags.ENERGY STAR ® CertifiedENERGY STAR ® certified models exceed government standards to help conserve natural resources and save money on yourutility bills.。

现代塔吊手册-T560说明书

现代塔吊手册-T560说明书

T560LOAD RADIUS (FT)10121520253035404550556065707580859095100105LOAD RADIUS (FT)10121520253035404550556065707580859095100105COUNTERWEIGHT:UPPER:W/AUX. WINCH 9900 LBS.W/O AUX. WINCH 11000 LBS.BOOM LENGTH 35-110 FT.STABILITY PERCENTAGE.ON OUTRIGGERS 85%ON TIRES 75%PCSA CLASS 10-196MODEL T560CAUTION: Do not use this specification sheet as a load rating chart. The formatof data is not consistent with the machine chart and may be subject to change.Lifting Capacities – Pounds (35' – 110' boom)** MAXIMUM CAPACITY AT 0 DEGREE BOOM ANGLEBOOM LENGTH 35 FT BOOM LENGTH 50 FT BOOM LENGTH 65 FT BOOM LENGTH 80 FT BOOM LENGTH 95 FT BOOM LENGTH 110 FT BOOM BOOM BOOM BOOM BOOM BOOM LOAD OVER LOAD OVER LOAD OVER LOAD OVER LOAD OVER LOAD OVER RADIUS REAR 360°RADIUS REAR 360°RADIUS REAR 360°RADIUS REAR 360°RADIUS REAR 360°RADIUS REAR 360°(FT)(LB)(LB)(FT)(LB)(LB)(FT)(LB)(LB)(FT)(LB)(LB)(FT)(LB)(LB)(FT)(LB)(LB)31.221,000*21,000*46.212,800*12,800*61.28,400*8,30076.25,600*5,00091.23,700*2,900106.172,400*1,500ON OUTRIGGERS - FULLY EXTENDED AND WITH 11000 LB. COUNTERWEIGHTBOOM LENGTH 80 FTBOOM LENGTH 95 FT BOOM LENGTH 110 FT LOADED LOADED LOADED BOOM OVER BOOM OVER BOOM OVER ANGLE REAR 360°ANGLE REAR 360°ANGLE REAR 360°(DEG)(LB)(LB)(DEG)(LB)(LB)(DEG)(LB)(LB)72.738,700*38,700*68.933,600*33,600*72.329,300*29,300*65.029,600*29,600*69.125,900*25,900*72.122,900* 22,900*61.026,500*26,20065.923,000*23,000*69.320,500* 20,500*56.823,900*20,60062.520,800*20,800*66.518,400* 18,400*52.421,800*16,60059.118,900*16,80063.616,500* 16,500*47.718,60013,60055.517,300*13,80060.714,900*13,90042.715,80011,30051.715,900*11,50057.713,500*11,60037.113,5009,40047.813,7009,60054.512,300*9,70030.611,6007,80043.611,9008,10051.311,200*8,20022.610,0006,50039.010,3006,80047.810,300*6,9009.88,6005,30033.99,0005,70044.29,2005,900**28.17,9004,70040.48,1005,00020.86,8003,90036.17,1004,1009.05,9003,10031.56,2003,400**26.05,4002,80019.34,7002,2008.44,1001,700LOAD RADIUS (FT)10121520253035404550556065707580859095LOAD RADIUS (FT)10121520253035404550556065707580859095ON OUTRIGGERS - FULLY EXTENDED AND WITH 11000 LB. COUNTERWEIGHTBOOM LENGTH 35 FTBOOM LENGTH 50 FT BOOM LENGTH 65 FT LOADEDLOADED LOADED BOOM OVERBOOM OVER BOOM OVER ANGLE REAR 360°ANGLE REAR 360°ANGLE REAR 360°(DEG)(LB)(LB)(DEG)(LB)(LB)(DEG)(LB)(LB)66.7120,000*120,000*73.960,100*60,100*63.1106,500*106,500*71.560,100*60,100*57.583,400*83,400*67.960,100*60,100*73.258,800*58,800*47.160,200*60,200*61.560,100*60,100*68.552,200*52,200*34.546,100*46,100*54.847,500*47,500*63.746,900*46,900*14.836,600*32,00047.438,100*33,90058.638,700*34,400**39.031,300*25,30053.332,000*25,90028.826,10019,60047.626,80020,30012.421,00015,40041.321,90016,300**34.118,20013,20025.215,30010,80010.913,0008,800USE THESE CHARTS ONLY WHEN ALL OUTRIGGERS ARE FULLY EXTENDEDLOAD RADIUS (FT)101215202530354045505560657075LOAD RADIUS (FT)101215202530354045505560657075** MAXIMUM CAPACITY AT 0 DEGREE BOOM ANGLEBOOM LENGTHBOOM LENGTHBOOM LENGTHBOOM LENGTHBOOM LENGTHBOOM LENGTH35 FT50 FT65 FT80 FT95 FT110 FTLOAD LOAD LOAD LOAD LOAD LOAD RADIUS 360°RADIUS 360°RADIUS 360°RADIUS 360°RADIUS 360°RADIUS 360°(FT)(LB)(FT)(LB)(FT)(LB)(FT)(LB)(FT)(LB)(FT)(LB)31.24,000COUNTERWEIGHT:UPPER:W/AUX. WINCH 9900 LBS.W/O AUX. WINCH 11000 LBS.BOOM LENGTH 35-110 FT.STABILITY PERCENTAGE ON OUTRIGGERS 85%ON TIRES 75%PCSA CLASS 10-196MODEL T560CAUTION: Do not use this specification sheet as a load rating chart. The formatof data is not consistent with the machine chart and may be subject to change.Lifting Capacities – Pounds (35' – 110' boom)ON OUTRIGGERS - MID POSITION AND WITH 11000 LB. COUNTERWEIGHTBOOM LENGTH 35 FT BOOM LENGTH 50 FTBOOM LENGTH 65 FT BOOM LENGTH 80 FTBOOM LENGTH 95 FT BOOM LENGTH 110 FTLOADED LOADED LOADED LOADED LOADED LOADEDBOOM BOOM BOOM BOOM BOOM BOOMANGLE 360°ANGLE 360°ANGLE 360°ANGLE 360°ANGLE 360°ANGLE 360°(DEG)(LB)(DEG)(LB)(DEG)(LB)(DEG)(LB)(DEG)(LB)(DEG)(LB)66.7113,000*73.960,100*63.192,500*71.560,100*57.561,70067.960,100*73.258,800*47.134,20061.535,50068.536,10072.736,50034.521,90054.823,40063.723,90068.924,30072.324,50014.814,90047.416,50058.617,10065.017,40069.117,60072.117,700**39.012,00053.312,70061.013,00065.913,20069.313,30028.88,90047.69,60056.810,00062.510,10066.510,30012.46,50041.37,30052.47,70059.17,90063.68,000**34.15,50047.75,90055.56,20060.76,30025.24,10042.74,50051.74,80057.74,90010.92,80037.13,40047.83,60054.53,800**30.62,40043.62,70051.32,90022.61,60039.01,90047.82,10033.91,20044.21,400LOAD RADIUS (FT)10121520253035404550LOADRADIUS (FT)10121520253035404550ON OUTRIGGERS - RETRACTED AND WITH 11000 LB. COUNTERWEIGHTBOOM LENGTH 35 FT BOOM LENGTH 50 FTBOOM LENGTH 65 FT BOOM LENGTH 80 FTBOOM LENGTH 95 FT BOOM LENGTH 110 FTLOADED LOADED LOADED LOADED LOADED LOADEDBOOM BOOM BOOM BOOM BOOM BOOM ANGLE 360°ANGLE 360°ANGLE 360°ANGLE 360°ANGLE 360°ANGLE 360°(DEG)(LB)(DEG)(LB)(DEG)(LB)(DEG)(LB)(DEG)(LB)(DEG)(LB)66.751,20073.952,40063.136,60071.537,70057.524,40067.925,60073.226,10047.114,00061.515,30068.515,80072.716,10034.58,40054.89,80063.710,40068.910,70072.310,80014.84,90047.46,30058.67,00065.07,30069.17,50072.17,600**39.04,00053.34,60061.05,00065.95,20069.35,30028.82,20047.62,90056.83,30062.53,50066.53,60041.31,60052.42,00059.12,20063.62,40055.51,20060.71,400** MAXIMUM CAPACITY AT 0 DEGREE BOOM ANGLEBOOM LENGTH BOOM LENGTHBOOM LENGTHBOOM LENGTHBOOM LENGTHBOOM LENGTH35 FT50 FT65 FT80 FT95 FT110 FTLOAD LOAD LOAD LOAD LOAD LOAD RADIUS 360°RADIUS 360°RADIUS 360°RADIUS 360°RADIUS 360°RADIUS 360°(FT)(LB)(FT)(LB)(FT)(LB)(FT)(LB)(FT)(LB)(FT)(LB)31.213,400 46.25,900 61.22,500USE THESE CHARTSONLY WHEN ALLOUTRIGGERS ARE PINNEDIN MID POSITIONUSE THESE CHARTS WHENALL OUTRIGGER BEAMS ARE NOT IN EITHER THE MID OR FULLY EXTENDED POSITIONW/AUX. WINCH 6900 LBS.W/O AUX. WINCH 8000 LBS.ON OUTRIGGERS 85%ON TIRES 75%PCSA CLASS 10-196CAUTION: Do not use this specification sheet as a load rating chart. The formatof data is not consistent with the machine chart and may be subject to change.LOAD RADIUS (FT)10121520253035404550556065707580859095100105LOADRADIUS(FT)10121520253035404550556065707580859095100105ON OUTRIGGERS - FULLY EXTENDED AND WITH 8000 LB. COUNTERWEIGHTBOOM LENGTH 35 FTBOOM LENGTH 50 FT BOOM LENGTH 65 FT LOADED LOADED LOADED BOOM OVERBOOM OVER BOOM OVER ANGLE REAR 360°ANGLE REAR 360°ANGLE REAR 360°(DEG)(LB)(LB)(DEG)(LB)(LB)(DEG)(LB)(LB)66.7120,000*120,000*73.960,100*60,100*63.1104,000*104,000*71.560,100*60,100*57.581,400*81,400*67.960,100*60,100*73.258,800*58,800*47.158,700*58,700*61.559,900*59,900*68.552,200*52,200*34.544,900*41,90054.846,200*43,40063.746,900*44,10014.835,500*28,50047.437,000*30,30058.637,700*30,900**39.030,400*22,50053.331,100*23,10028.824,40017,20047.625,20017,90012.419,60013,30041.320,50014,200**34.117,00011,40025.214,2009,20010.911,9007,400**LOAD RADIUS (FT)10121520253035404550556065707580859095100105LOADRADIUS(FT)10121520253035404550556065707580859095100105ON OUTRIGGERS - FULLY EXTENDED AND WITH 8000 LB. COUNTERWEIGHTBOOM LENGTH 80 FTBOOM LENGTH 95 FT BOOM LENGTH 110 FT LOADED LOADED LOADED BOOMOVER BOOM OVER BOOM OVER ANGLE REAR 360°ANGLE REAR 360°ANGLE REAR 360°(DEG)(LB)(LB)(DEG)(LB)(LB)(DEG)(LB)(LB)72.738,700*38,700*68.933,600*33,600*72.329,300*29,300*65.029,600*29,600*69.125,900*25,900*72.122,900*22,900*61.026,500*23,40065.923,000*23,000*69.320,500*20,500*56.823,900*18,20062.520,800*18,40066.518,400*18,400*52.420,80014,60059.118,900*14,80063.616,500*14,90047.717,40011,80055.517,300*12,00060.714,900*12,10042.714,6009,70051.714,8009,90057.713,500*10,00037.112,4007,90047.812,7008,20054.512,300*8,30030.610,6006,50043.610,9006,80051.311,0006,90022.69,1005,30039.09,4005,60047.89,6005,7009.87,8004,20033.98,1004,60044.28,3004,800**28.17,0003,70040.47,2003,90020.86,1002,90036.16,3003,2009.05,2002,20031.55,5002,500**26.04,7001,90019.34,0001,4008.43,400,900** MAXIMUM CAPACITY AT 0 DEGREE BOOM ANGLEBOOM LENGTH 35 FT BOOM LENGTH 50 FT BOOM LENGTH 65 FT BOOM LENGTH 80 FT BOOM LENGTH 95 FT BOOM LENGTH 110 FT BOOM BOOM BOOM BOOM BOOM BOOM LOAD OVER LOAD OVER LOAD OVER LOAD OVER LOAD OVER LOAD OVER RADIUS REAR 360°RADIUS REAR 360°RADIUS REAR 360°RADIUS REAR 360°RADIUS REAR 360°RADIUS REAR 360°(FT)(LB)(LB)(FT)(LB)(LB)(FT)(LB)(LB)(FT)(LB)(LB)(FT)(LB)(LB)(FT)(LB)(LB)31.221,000*21,000*46.212,800*12,50061.28,400*6,90076.25,600*3,90091.23,700*2,000106.172,400*700USE THESE CHARTS ONLY WHEN ALL OUTRIGGERS ARE FULLY EXTENDEDW/AUX. WINCH 3900 LBS.W/O AUX. WINCH 5000 LBS.ON OUTRIGGERS 85%ON TIRES 75%PCSA CLASS 10-196CAUTION: Do not use this specification sheet as a load rating chart. The formatof data is not consistent with the machine chart and may be subject to change.LOAD RADIUS (FT)10121520253035404550556065707580859095100105LOAD RADIUS (FT)10121520253035404550556065707580859095100105ON OUTRIGGERS - FULLY EXTENDED AND WITH 5000 LB. COUNTERWEIGHTBOOM LENGTH 35 FTBOOM LENGTH 50 FT BOOM LENGTH 65 FT LOADED LOADED LOADED BOOM OVER BOOM OVER BOOM OVER ANGLE REAR 360°ANGLE REAR 360°ANGLE REAR 360°(DEG)(LB)(LB)(DEG)(LB)(LB)(DEG)(LB)(LB)66.7120,000*120,000*73.960,100*60,100*63.1101,300*101,300*71.560,100*60,100*57.579,300*79,300*67.960,100*60,100*73.258,800*58,800*47.157,000*57,000*61.558,400*58,400*68.552,200*52,200*34.543,600*37,60054.844,900*39,10063.745,600*39,70014.834,400*25,30047.435,900*27,10058.636,600*27,700**39.029,10020,00053.329,70020,60028.822,70015,20047.623,50015,90012.418,10011,60041.319,10012,500**34.115,70010,00025.213,0007,90010.910,8006,200**USE THESE CHARTS ONLY WHEN ALL OUTRIGGERS ARE FULLY EXTENDED** MAXIMUM CAPACITY AT 0 DEGREE BOOM ANGLEBOOM LENGTH 35 FT BOOM LENGTH 50 FT BOOM LENGTH 65 FT BOOM LENGTH 80 FT BOOM LENGTH 95 FT BOOM LENGTH 110 FT BOOM BOOM BOOM BOOM BOOM BOOM LOAD OVER LOAD OVER LOAD OVER LOAD OVER LOAD OVER LOAD OVER RADIUS REAR 360°RADIUS REAR 360°RADIUS REAR 360°RADIUS REAR 360°RADIUS REAR 360°RADIUS REAR 360°(FT)(LB)(LB)(FT)(LB)(LB)(FT)(LB)(LB)(FT)(LB)(LB)(FT)(LB)(LB)(FT)(LB)(LB)31.220,900*20,900*46.212,700*10,80061.28,300*5,80076.25,600*3,10091.23,700*1,400106.172,300*LOAD RADIUS (FT)10121520253035404550556065707580859095100105LOAD RADIUS (FT)10121520253035404550556065707580859095100105ON OUTRIGGERS - FULLY EXTENDED AND WITH 5000 LB. COUNTERWEIGHTBOOM LENGTH 80 FTBOOM LENGTH 95 FT BOOM LENGTH 110 FT LOADED LOADED LOADED BOOM OVER BOOM OVER BOOM OVER ANGLE REAR 360°ANGLE REAR 360°ANGLE REAR 360°(DEG)(LB)(LB)(DEG)(LB)(LB)(DEG)(LB)(LB)72.738,700*38,700*68.933,600*33,600*72.329,300*29,300*65.029,600*28,10069.125,900*25,900*72.122,900*22,900*61.026,500*20,90065.923,000*21,20069.320,500*20,500*56.823,80016,20062.520,800*16,40066.518,400*16,60052.419,40012,90059.118,900*13,10063.616,500*13,20047.716,10010,40055.516,30010,60060.714,900*10,70042.713,5008,40051.713,7008,60057.713,500*8,70037.111,4006,80047.811,6007,00054.511,8007,20030.69,6005,50043.69,9005,80051.310,1005,90022.68,2004,40039.08,5004,70047.88,7004,8009.86,9003,40033.97,3003,80044.27,5003,900**28.16,2003,00040.46,4003,20020.85,3002,20036.15,5002,5009.04,5001,60031.54,7001,900**26.04,0001,30019.33,4000,8008.42,800W/AUX. WINCH 9900 LBS.W/O AUX. WINCH 11000 LBS.ON OUTRIGGERS 85%ON TIRES 75%PCSA CLASS 10-196CAUTION: Do not use this specification sheet as a load rating chart. The formatof data is not consistent with the machine chart and may be subject to change.ON TIRES WITH 11000 LB. COUNTERWEIGHTMAX ALLRADIUS BOOM PICK & CARRY (FT)LENGTH STATIONARY CREEP 2.5 MPH(FT)STRAIGHT OVER REAR103523,50023,50016,100*123522,40022,40014,400*153520,70020,70012,200*205018,00016,7009,200*255015,20013,6006,900*305011,20011,0005,000*35508,9008,9003,700*40657,4007,4002,800*45656,0006,0002,100*50654,7004,7001,500*55653,8003,80060803,0003,00065802,3002,30070801,8001,800SIDE STOW JIB ON FULLY EXTENDED OUTRIGGERS WITH 11000 LB. COUNTERWEIGHT33 FT OFFSETTABLE JIB57 FT OFFSETTABLE JIB 0°OFFSET15°OFFSET 30°OFFSET O°OFFSET 15°OFFSET 30°OFFSETLOADED (REF)(REF)(REF)(REF)(REF)(REF)LOADEDBOOM LOAD REAR LOAD REAR LOAD REAR LOAD REAR LOAD REAR LOAD REAR BOOM ANGLE RADIUS ONLY 360°RADIUS ONLY 360°RADIUS ONLY 360°RADIUS ONLY 360°RADIUS ONLY 360°RADIUS ONLY 360°ANGLE (DEG)(FT)(LB)(LB)(FT)(LB)(LB)(FT)(LB)(LB)(FT)(LB)(LB)(FT)(LB)(LB)(FT)(LB)(LB)(DEG)754212,600*12,600*498,500*8,500*566,600*6,600*506,600*6,600*644,600*4,600*743,400*3,400*75734711,900*11,900*548,200*8,200*696,400*6,400*566,200*6,200*694,400*4,400*793,300*3,300*73715311,300*11,300*597,800*7,800*656,300*6,300*625,900*5,900*754,200*4,200*853,200*3,200*71686010,400*9,900667,400*7,400*716,000*6,000*705,600*5,600*823,900*3,900*913,100*3,100*6865679,600*8,300727,100*7,100*775,900*5,900*785,200*5,200*903,700*3,700*973,000*3,000*6562738,900*6,800786,800*6,100835,700*5,700*864,800*4,800*973,500*3,500*1042,900*2,900*6259808,300*5,700846,500*5,100895,500*4,900954,500*4,4001043,400*3,400*1102,800*2,800*5955876,9004,500916,200*4,200965,300*4,0001054,100*3,5001123,200*3,200*1172,700*2,700*5551935,8003,500995,5003,3001035,200*3,1001143,800*2,7001203,000*2,5001242,700*2,2005147995,0002,8001064,7002,5001094,7002,5001223,500*2,1001272,900*1,9001302,600*1,80047431064,3002,1001124,1002,0001144,0001,9001293,300*1,5001342,800*1,4001362,600*1,30043381143,6001,5001193,4001,4001203,3001,3001372,7001,0001412,60001,0001422,600*0,90038321212,8000,9001252,7000,8001272,7000,8001452,2001482,1001492,10032251282,2001312,1001521,7001541,60025171341,8001361,7001591,3001591,300170140,500*164,400*MAXIMUM PERMISSIBLE HOIST LINE LOADLINE PARTS 1234567891011*MAIN & AUX. HOIST11,25022,50033,75045,00056,25067,50078,75090,000101,250112,500123,750WIRE ROPE:5/8" ROTATION RESISTANT COMPACTED STRAND, 34 X 7, GRADE 2160, MINIMUM BREAKING STRENGTH – 28.21 TONS5/8"6 X 19 OR 6 X 37 XIPS, IWRC, PREFORMED, RIGHT REGULAR LAY MINIMUM BREAKING STRENGTH – 20.6 TONS* IF SIX SHEAVES ARE NOT INSTALLED IN THE BOOM HEAD, THE FIRST PART OF LINE MAY BE ROUTED OVER THE AUXILIARY BOOM HEAD SHEAVE. THIS REEVING MAY ONLY BE USED AT MINIMUM RATED RADIUS. DO NOT PULL THE HOOK BLOCK CLOSER THAN 10 FT. FROM THE BOOM HEAD WITH A LOAD ON THE HOOK BLOCK!NOTES FOR ON TIRE CAPACITIESA.For Pick and Carry operations, boom must be centered over the rear of the crane with swing brake and lock engaged. Use minimum boom point height and keep load close to ground surface. Travel must be on smooth level surface.B.The load should be restrained from swinging. NO ON TIRE OPERATION WITH JIB ERECTED.C.Without outriggers, never maneuver the boom beyond listed load radii for applicable tires to ensure stability.D.Creep speed is crane movement of less than 200 Ft.(61m) in a 30 minute period and not exceeding 1.0 mph(1.6 km/h).E.Refer to General Notes for additional information.Notes For Jib Capacities:A. For all boom lengths less than the maximum with a jib erected,the rated loads are determined by boom angle only in the appropriate column.B. For boom angles not shown,use the capacity of the next lower boom angle.C. Listed radii are for fully extended main boom only.TEREX Cranes106 12th Street S.E. Waverly, IA50677-9466 USA TEL: +1 (319) 352-3920 FAX: +1 (319) 352-5727 EMAIL:************************。

RPU560A 安保模块 用户手册说明书

RPU560A 安保模块 用户手册说明书

RPU560A 安保模块用户手册目次前言 (3)1 概述 (4)2 性能和特点 (4)3 技术参数 (4)4 工作过程 (5)4.1 安保主用模式 (5)4.2 安保备用模式 (5)5 保护 (6)5.1 警告/预警 (6)5.2 停机报警 (6)6 参数配置 (7)7 输出口功能定义 (8)8 接线端子描述 (9)9 系统接线图 (11)10 典型应用图 (12)11 安装 (12)12 故障排除 (13)前言是众智的中文商标是众智的英文商标SmartGen ― Smart的意思是灵巧的、智能的、聪明的,Gen是generator(发电机组)的缩写,两个单词合起来的意思是让发电机组变得更加智能、更加人性化、更好的为人类服务。

不经过本公司的允许,本文档的任何部分不能被复制(包括图片及图标)。

本公司保留更改本文档内容的权利,而不通知用户。

公司地址:郑州高新区金梭路28号电话:+86-371-67988888/67981888/67992951+86-371-67981000(外贸)传真:+86-371-67992952网址://邮箱:*****************表1版本发展历史日期版本内容2015-08-10 1.0 开始发布。

2015-12-15 1.1 更改英文说明书中RPU560A的全称名。

2021-08-15 1.2 增加紧急停机断线检测,更改电源电压输入描述。

2022-10-10 1.3 更新公司logo和说明书格式。

表2本文档所用符号的说明符号说明该图标提示或提醒操作员正确操作。

注意该图标表示错误的操作有可能损坏设备。

小心该图标表示错误的操作有可能会造成死亡、严重的人身伤害和重大的财产损失。

警告1概述RPU560A安保模块是一个能够独立运行保护发动机正常运转的模块,该模块通过CANBUS和主控HMC9000/HMC6000连接,所有数据和停机报警信息都能够通过主控模块查看。

适用于船用主推、主发、应急机组或水泵机组。

en560变频器使用说明书

en560变频器使用说明书

en560变频器使用说明书一、用户须知1、该变频调速装置为电力电子器件组成,在运输及安装过程中,尽量避免强烈的震动,尽量垂直运输。

2、该变频调速装置尽量安装在干燥通风的区域,变频器的散热片距墙壁或遮挡物距离应大于10米。

3、长期不用时,应存放在清洁干燥的地方;在井下安装好而不运行的状况下,该设备尽量不停电。

4、使用之前,必须详细阅读用户手册。

二、注意事项1、变频调速装置其隔爆外壳体及本安控制盒的结构和非本安及本安电路的电气参数,在出厂前均已装配调试合格,用户严禁改动变频调速装置壳体的结构和电气参数,以确保本产品的防爆性能、电气性能和本安性能。

2、设备在带电情况下,严禁松动隔爆壳紧固件,在检修或处理故障时,请注意“断电源后开盖”。

(注:本安接线腔不受此限制)3、外壳应接地良好。

4、电源接线隔爆腔在接线时请注意按图接线,不得接错。

5、装置防爆主腔内进行操作时,手上必须带接地导线或静电环。

6、装置电源R、S、T停电以后5分钟内禁止对变频器隔爆主腔内的任意电路进行操作,且必须用仪表确认机内电容已放电完毕,方可实施机内作业。

停电以后1分钟内禁止再次给电。

三、系统简介ZJT30型隔爆兼本安智能变频调速装置以下简称变频调速装置。

该变频调速装置主要整流及逆变元件采用进口产品,具有可靠性高,使用寿命长等特点、它能有效地保护各种设备的电机,延长电机的使用寿命。

由于变频调速装置采用了隔爆兼本质安全型设计,符合煤矿安全规程,可应用于煤矿井下含有煤尘、瓦斯爆炸危险的环境中,作为局部风机、水泵、空压机、提升绞车、皮带运输机及其它设备电机的变频调速和起停及保护控制,从而实现节能降耗、安全生产、延长电机使用寿命等多重相的、ZJT30型隔爆兼本安智能变频调速装置四象限为绞车专用的电气传动装置,可实现绞车的调速、换向、能量回馈制动等功能其主要配置为输入电抗器、可控整流系统、电容平波系统、输出逆变系统。

技术参数:1、输入电源电压AC660V士10%,频率50Hz。

EB500用户使用手册

EB500用户使用手册

目录绪 言 (5)第一章 关于EVIEW 500的安装 (7)1.1 安装E ASY B UILDER500 (7)1.2系统连接图 (11)第二章 制作一个最简单的工程 (13)2.1 第一步 (13)2.2 创建一个开关元件 (15)第三章 EVIEW MT500的软件 (21)3.1 E ASY M ANAGER (21)3.2下载 (23)3.3上传 (25)3.4 PLC A DDRESS V IEW (26)3.5 E ASY B UILDER界面 (28)3.5.1 EB500界面 (29)3.5.2 菜单[文件] (31)3.5.3 菜单[编辑] (34)3.5.4 菜单[视图] (42)3.5.5 菜单[选项] (47)3.5.6 菜单[绘图] (48)3.5.7 菜单[元件] (54)3.5.8 菜单[图库] (54)3.5.9 菜单[工具] (54)3.5.10 菜单[窗口] (55)3.5.11 菜单[帮助] (55)3.6 在线模拟 (56)3.7 离线模拟 (57)3.8 辅助工具 (57)第四章 窗口 (63)4.1 窗口类型 (63)4.2 窗口属性 (66)4.3 创建一个窗口 (67)4.4 打开窗口 (68)4.5 几个关于窗口的例子 (70)4.6 和窗口有关的元件 (75)4.7 窗口资源分布 (75)第五章 EB500的基本设计方法 (77)5.1 设计元件 (77)5.2 关于元件ID 号 (77)5.3 附加注解(描述) (78)5.4 输入PLC的读/写地址 (78)5.5 添加向量图 (80)5.6 添加位图 (82)5.7 创建标签 (84)5.8 工作按钮 (86)5.9 向量图库 (89)5.10 位图库 (93)5.11 群组图库 (97)5.12 压缩工程 (99)第六章 元件 (102)6.1 位状态指示灯 (102)6.2 多状态指示灯 (104)6.3 位状态设定 (105)6.4 多状态设定 (106)6.5 位状态切换开关 (109)6.6 多状态切换开关 (110)6.7 功能键 (111)6.7.1 切换基本窗口 (111)6.7.2 返回到前一窗口 (111)6.7.3 切换公用窗口 (112)6.7.4 窗口控制条 (112)6.7.5 最小化窗口 (112)6.7.6 弹出窗口 (112)6.7.7 关闭窗口 (113)6.7.8 切换快选窗口 (113)6.7.9 字符码和创建小键盘 (116)6.7.10 留言板 (118)6.7.11 打印功能 (118)6.8 移动图形 (119)6.9 动画 (121)6.10 数值输入 (123)6.11 数值显示 (129)6.12 文本输入 (130)6.13 文本显示 (134)6.14 棒图 (135)6.15 表针 (137)6.16 间接窗口 (138)6.17 直接窗口 (140)6.18 报警信息登录 (142)6.19 报警信息显示 (142)6.20 趋势图 (144)6.21 报警条 (151)6.22 配方数据传输 (153)6.23 数据传输 (153)6.24 事件登录 (155)6.25 事件显示 (157)6.26 PLC控制 (161)6.27 宏指令 (165)6.28 系统信息 (189)6.29 关于元件的叠加 (189)第七章 系统参数 (191)7.1 PLC设置 (192)7.2 一般 (193)7.3 指示灯 (195)7.4 安全等级 (196)7.5 编辑器 (196)7.6 硬件 (199)第八章 配方数据 (202)8.1 创建一个配方数据传输元件的过程。

EBV说明书全文(PCV阀)1

EBV说明书全文(PCV阀)1

Consolidated®安装、操作与维护手册带有2537控制台和3539控制器的Consolidated®电动球阀系统德莱塞测量与控制部美国路易斯安那州亚历山大市71309-14302002年10月修订版目录章题目页Ⅰ.安全注意事项 (4)Ⅱ. 安全防护措施 (5)III.产品安全标识系统 (6)IV.安全警告 (6)V.质量保证 (9)VI.介绍 (10)VII.系统的设计特点 (10)VIII.操作原理——电气系统 (11)Ⅸ. 安装前的保管及搬运 (14)Ⅹ. 安装操作建议 (15)A.主阀 (15)B. 3539型控制器 (16)Ⅺ. 水压试验 (17)Ⅻ. 系统的启动 (17)A. 启动前的检查 (17)B.系统启动 (17)C.调整设定压力及回座 (17)D.最低的回座设定 (19)B. 执行机构组件的拆卸 (22)C. 阀杆的拆卸 (23)ⅩⅣ. 清洗 (24)ⅩⅤ. 检查 (24)ⅩⅥ. 维护 (24)A. 阀座泄漏 (24)C. 填料泄漏 (27)D. 电气系统 (28)ⅩⅦ. 重新装配 (31)A.润滑 (31)B.所需工具 (31)C. 阀门装配 (31)ⅩⅧ. 库存 (33)A.概要 (33)B.库存计划-替换零件列表 (33)C.建议使用的备件 (34)D.识别并定购要件 (34)XIX.维护工具 (35)XX.厂商现场服务与维修计划 (38)A.厂家设定与现场设定 (38)B.现场服务 (38)C.厂家的维修设施 (38)Ⅰ.安全注意事项正确地安装, 使用及维护对於阀门产品的安全和可靠运行是必不可少的。

由德莱赛阀门业务部推荐和本说明书中所述的有关程序是完成所需作业的有效方法。

重要的一点应指出,本说明书包括了应仔细阅读的各种"安全信息",使对人身伤害危险性降至最低,或使采用不正确的程序而损坏德莱赛阀门产品的可能性降至最低,或降低使产品不安全的因素。

azbil VY560 A 大口径法兰型比例二通阀 说明书

azbil VY560 A 大口径法兰型比例二通阀 说明书
Q d2
Q:流量 (ℓ/min) d :阀门的公称口径 (mm)
5
AI-6830C
■安 装 注 意

• 请在电源断开的状态下对专用执行器进行安装。 否则,将会导致设备故障。 • 配管时,请确保管道内无异物残留。此外,在配管之后要进行冲洗,以清除管内异物。如果有异物进入 到管道内,将导致故障。 • 请勿在含具有腐蚀执行器、专用阀门以及其它相关零件的氧化性气体或爆炸性气体的空气环境中使用本 产品。 • 请勿将本产品与蒸汽盘管、高温水盘管等进行邻接安装。 受高温辐射时,将导致执行器运行不良。
图 2 外形尺寸 (mm): VY5603A 表 1 尺寸表 (mm): VY5603A
连接口径(mm) 100 125 150
L 352 403 451
L1 153 172 183
H 309.5 309.5 318
H1 171.5 171.5 180
φD 210 250 280
φC 175 210 240
AI-6830C
规格・使用说明书
大口径法兰型比例二通阀 高差压对应系列 VY560*A
■概 要
ACTIVAL VY560*A 是高差压对应系列大口径法兰型 比例二通阀。通过与专用执行器 MY56*0C*组合,可被 用于热源周边的压力控制泵旁通阀等设备上。阀体额定 压力等级与 JIS 10K 和 GB PN16 对应。
t 24 24 26
φh 19 23 23
N 8 8 8
质量(kg)* 35 35 47
* 不包括执行器的质量。
●VY5609A (GB PN16-FC200)
最小100*1
最小300 专用执行器
N × φh H H1 φC

四川埃姆克伺服主轴选型手册v1.0

四川埃姆克伺服主轴选型手册v1.0

额定功率 (kW)
2.2 3.7 5.5 3.7 5.5 7.5 7.5 11 15
额定转矩 (Nm)
7 11.7 17.5 11.7 17.5 24 24 35 48
电机型号
DH09-1-14-2.2/3.7-1500 DH09-2-24-3.7/5.5-1500 DH10-1-24-3.7/5.5-1500 DH10-2-35-5.5/7.5-1500 DH10-3-48-7.5/11-1500 DH13-1-71-11/15-1500 DH13-2-95-15/18.5-1500 DH13-3-117-18.5/22-1500 DH13-4-140-22/30-1500 DH16-1-191-30/37-1500
265
15
110
5
DH13-4-140-22/30-1500
265
230
265
15
110
5
DH16-1-191-30/37-1500
320
300
350
19
140
5
D
Q
L
H
28
8
420
240
28
8
470
240
38
10
470
275
38
10
510
275
38
10
560
275
48
14
620
355
48
14
665
额定功率 (kW)
2.2 3.7 3.7 5.5 7.5 11 15 18 22 30
额定转矩 (Nm)
14 24 24 35 48 71 95 117 140 191

高效发电与智能营维系统说明书

高效发电与智能营维系统说明书

SUN2000-125KTL-M0SUN2000-110KTL-M0S O L A R.H U A W E I.C O MSUN2000-125KTL-M0智能光伏控制器效率曲线支持IV诊断最大效率99.0%无熔丝设计IP66防护等级20路高精度组串检测10路MPPT 支持MBUS 通信内置交直流防雷90%91%92%93%94%95%96%97%98%99%100%0%20%40%60%80%100%625V 750V 850V 负载率效率SUN2000-125KTL-M0技术参数SUN2000-75KTL-C1智能光伏控制器支持IV 诊断最大效率99%无熔丝设计IP65防护等级12路高精度组串检测6路MPPT 支持PLC 通信内置交直流防雷L1L2L3PESUN2000-75KTL-C1技术参数SUN2000-70KTL-C1智能光伏控制器支持IV 诊断最大效率99%无熔丝设计IP65防护等级12路高精度组串检测6路MPPT 支持PLC 通信内置交直流防雷L1L2L3PESUN2000-70KTL-C1技术参数SUN2000-110KTL-M0智能光伏控制器效率曲线支持IV诊断最大效率98.6%无熔丝设计IP66防护等级直流开关输出继电器EMI SPD90%91%92%93%94%95%96%97%98%99%100%0%20%40%60%80%100%540V 600V 800V 20路高精度组串检测10路MPPT 支持MBUS 通信内置交直流防雷效率负载率SUN2000-110KTL-M0技术参数直流电器L1L2L3PE滤波N 防雷SUN2000-60KTL-M0智能光伏控制器支持IV 诊断最大效率98.6%无熔丝设计IP65防护等级12路高精度组串检测6路MPPT 支持PLC 通信内置交直流防雷SUN2000-60KTL-M0技术参数SmartACU2000C智能子阵控制器智能灵活支持防逆流功能支持2G/3G/4G 通信稳定可靠IP65高防护等级,适合户外使用简单易用1:放在金属柜体中,可选配室外远拉天线支持防逆流功能支持2G/3G/4G通信内置防雷提升设备安全SmartLogger 1000A数据采集器智能灵活稳定可靠简单易用智能灵活支持10台逆变器共享资源支持2G/3G/4G/WLAN 通信稳定可靠断链可自动重链简单易用1:1拖2和1拖10通信棒分别支持2台逆变器和10台逆变器的通信;2:逆变器之间用RS485连接。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

裝置說明書型式:EA560型
技-AD-004
機機械械軸軸封封的的使使用用方方法法
在機械軸封的選定及取付部上雖經正確的設計及要求,但裝配組立如粗心大意,皆無法
完全發揮軸封的性能。

機械軸封是一種高精密的機械裝置部品,在使用以前,一定要遵守正確的使用方法。

在這裡就機械軸封使用上的注意點以及組立的順序做說明。

一一、、包包裝裝〃〃保保管管
1. 交客戶的機械軸封是以塑膠袋或防銹紙包裝。

請特別注意不要隨意開封以避免灰塵附
著或弄傷。

2. 摺動面是軸封的生命,它是經過特別精密的加工,特別是碳精摺動面很容易因碰傷而產生刮痕,開封時摺動面要特別的注意保護。

3. 開封以後如不馬上使用也要防止砂粒灰塵等異物混入,請好好保管。

4. 紫外線會使橡膠產生劣化現象,應避免長時間太陽光的直接照射。

5. 高溫、溼氣重的場所也會促使橡膠劣化及造成摺動面平坦度歪變的原因請注意。

6. 按裝及運轉時避免衝擊的現象。

二二、、裝裝配配前前的的準準備備
1. 機械軸封的檢查:
雖然經過萬全的品管與包裝但請再做以下之檢查。

A. 部品是否齊全,請確認。

B. 摺動面有無異物附著?
如果有異物請以乾淨之柔軟布沾MEK 擦拭之。

這時候橡膠類部品請勿沾到,同時摺動面也避免刮傷。

C. 請檢查摺動面有無缺角、割痕?
如有請更換新品。

D. 橡膠迫緊類部品密封部請檢查是否有傷痕或異物?
如有異物時,請以乾淨布擦拭之。

2. 欲裝置的機器檢查:
A. 請確認機械軸封裝置部位置的形狀、尺寸及加工精度。

B. 請確認橡膠迫緊部品的密封部接觸位置有無凹(刮)痕、毛邊及異物。

C. 回轉軸的徑向、軸向是否有鬆動現象?
如有鬆動現象,請使換軸承。

三三、、運運轉轉時時的的注注意意
1. 機械軸封裝配後的檢查:
A. 確認機械軸封是否正確的裝配至正確位置。

B. 所有循環液配管是否都實施配置。

C. 以手轉動回轉軸,是否有漏的現象同時檢查葉輪是否有異音及異常之現象。

2. 當機器運轉時:
A. 絶對禁止空運轉。

因為會促使摺動面異常發熱及損傷和橡膠部品的熱硬化造成液體洩漏的主要原因。

B. 確認回轉方向是否正確。

C. 開始運轉後有若干少量液體漏的現象嗎?
D. 這是組立時,液體對摺動面所產的的一種初期洩漏現象(摺動面親和階段)。

但這種現象會慢慢減少。

E. 長時間停止運轉之場合,如機器再運轉時,起動之扭矩會相當大,這時請先以手轉動主軸。

四四、、機機械械軸軸封封的的組組裝裝 步步驟驟11------------固固定定環環的的組組立立
1. 裝置部以乾淨布擦拭之後,並塗抺薄層的潤
滑油。

(建議油品CPC R32)
2. 為使插入更容易,CUP GASKET 的外周部塗
抹清水後,再裝入殼體。

3. CUP GASKET & MATING RING 一起裝入
殼體(如圖-1)。

或CUP GASKET 先裝入殼體,緊接著MATING RING 再組立至正確位置(如圖-2)。

4. 裝配時使用插入治具○A (以不會弄傷MATING RING 之塑膠管材治具)對組立之工作會更簡單及更有效率。

5. 有關摺動面異物的清除可利用乾淨布沾
MEK 擦拭之。

CUP GASKET 裝入殼體內是否至正確位置? MATING RING 裝入時是否有傾斜現象?
步步驟驟22------------馬馬達達側側回回轉轉環環的的組組立立
1. BELLOWS 的內周部及插入治具○B 與軸外徑
以乾淨布沾NEK 擦拭潔淨,然後塗抹一薄層之潤滑油,再將回轉環裝入軸心上。

2. 裝配時可利用插入治具○A ,押入之程度,與
MATING RING 的摺動面輕輕碰觸的感覺即可。

(如圖-4)
裝配時,摺動面避免碰觸軸心以免發生缺損,請注意
3. 完成上述步驟之後再將彈簧與彈簧承座華司
裝入。

(如圖-5) 4. 按置IMPLLER 定位,使機械軸封完成正確
的壓縮長度。

IMPLLER 的按裝請於回轉部組裝後10分鐘內完成,確保機械軸封正確之壓縮
步步驟驟33------------組組立立後後的的檢檢查查
1. 以手輕轉葉片或軸確認是否轉動滑順或干
涉。

2. 機械軸封在正確的組立裝著後,須實施靜態
試驗檢查。

測試的方法可採用氣壓或液壓方式,依壓力的降下狀況對機械軸封實施檢查。

3. 組立後,靜置約30分以上。

放置後檢查
BELLOWS 內周部塗布之潤滑油是否會滑動而影響回轉環無法固定在軸上。

CUP GASKET 接觸填料函之端面 與軸心成直角。

TIR=0.2mm 以下(於最大外徑)。

相关文档
最新文档