TLC226X中文资料

合集下载

Lorex LNC226X系列无线高清网络摄像头说明书

Lorex LNC226X系列无线高清网络摄像头说明书

FEATURES:• View, record & playback in real-time HD• Weatherproof indoor/outdoor camera (IP66 rated) • Cold climate capability (operates to -4°F/ -20°C)• Record to smartphone, tablet, PC, Mac or NASFEATURES:• iOS, Android, PC and Mac compatible*• Real-Time (30fps) HD 1280x800 Mega-pixel resolution • Wi-Fi & wired internet connectivity• 5 Second pre-recording on SD cardLNC226X SpecificationsMode: Day & NightPower: 20V, 0.6AProcessors: RISC CPU, hardware video processing andcompressionNetwork interface: Ethernet 10BaseT/100BaseTX, Auto-MDIX, RJ-45 Wireless interface: IEEE 802.11b/g/nImage sensor: HD up to 1280x800 resolution1/4” Megapixel Color CMOSSeparate sensors for day and night with automaticgain, white balance, exposure and brightness control Light sensitivity: 0.2 Lux (IR LED off)0 Lux (with 9 meters IR LED on)Automatically turn on the IR LED in low lightenvironmentLens: 4.2mm, F2.4, viewing angle: 62°, fixed irisDay and night separate lensButtons: One reset button, to factory default settingsOne WPS button for automatic WiFi setup Indicators: One LED for Internet connection status indicationOne LED for Ethernet connection indicationOne LED for SD card recording indicationVideo compression: H.264Video streaming: Separate frame rate/resolution/bandwidth settingsfor PC and mobileResolution: 1280x800, 1024x768, VGA (640x480), QVGA(320x240)Bandwidth: 64Kbps ~ 3MbpsFrame rate: 1~30fpsAudio: Built-in microphone for audio monitoringVideo management software: L-View software for viewing and archiving up to 16cameras (PC/Mac)Lorex Ping app for viewing cameras on mobile(iOS/Android™)Security: Web management username/password protectionVideo display ID/password protectionWiFi WEP and WPA/WPA2 security mode Installation, management and maintenance:Plug & play by ID/passwordFirmware upgrades by FTPL-View SW upgrade Push Notification Users: Up to 20 simultaneous users (depends on videosettings and Internet bandwidth)Alarm and event management: Events triggered by motion and sound detectionE-mail/FTP alarm messagePush notification on supported mobile devices Approvals: EMC — CE, FCC Part 15 Subpart B Class B, IC Class BWireless RF — CE, FCC Part 15 Subpart C Indoor / Outdoor: Both (IP66 rated)*Operating conditions: -20 – 50°CHumditiy 20–80% RH (non-condensing) Dimensions (W x D x H): 58 x 230 x 52mm / 2.3 x 9.1 x 2.1”Weight: 0.37kg / 0.81lbs (including camera bracket)LNC204 SpecificationsMode: Day & NightPower: 5V (USB) - 12V, 1AProcessors: RISC CPU, hardware video processing andcompression.Network interface: Ethernet 10BaseT/100BaseTX, Auto-MDIX, RJ-45 Wireless interface: IEEE 802.11b / g / nImage sensor: HD up to 1280x800 resolution1/4" Megapixel Color CMOSSeparate sensors for day and night with automaticgain, white balance, exposure and brightnesscontrolPIR sensor: Effective distance – 7 metersLight sensitivity: 0.2 Lux ( IR LED off )0 Lux (with 9 meters IR LED on)Automatically turn on the IR LED on low lightenvironment.Infrared thermometer: Infrared Range: -40 ~ 115 °C, accuracy:+-0.5°C Lens: 4.2 mm, F2.4, viewing angle: 66°, fixed iris.Day and night separate lensButtons: One reset button, to factory default settingsOne WPS button for automatic WiFi setup Indicators: One LED for Internet connection status indicationOne LED for Ethernet connection indicationOne LED for SD card recording indicationVideo compression: H.264, baseline profile level 3.1Video streaming: Separate frame rate/resolution/bandwidth settingsfor PC and mobile.Resolution: 1280x800, 1024x768, VGA(640x480),QVGA(320x240)Bandwidth: 64Kbps ~ 3MbpsFrame rate: 1~30 fpsAudio: Built-in 0.5W speaker for alarm and half-duplextwo-way audio.Speaker jack for external speakerVideo management software: L-View software for viewing and recording up to 4cameras (PC/Mac)Lorex Ping app for viewing cameras on mobile (iOS/Android™)Security: Web management username/password protectionVideo display ID/password protectionWiFi WEP and WPA/WPA2 security mode Installation, management and maintenance:Plug & play by ID/password.Firmware upgrades via FTPL-View SW upgrade Push NotificationUsers Up to 20 simultaneous users (depends on videosettings and internet bandwidth)Alarm and event management: Events triggered by PIR and sound detectionEmail/ftp alarm messageTemperature alarm for low/high room temperaturePush notification on supported mobile devices. Dimensions: 68 x 25 x 95mm/2.8 x 1.0 x 3.7" (W x D x H) Weight: 0.28kg/0.62lbs (including camera bracket) Approvals: EMC - CE, FCC Part 15 Subpart B Class B, IC Class BWireless RF - CE, FCC Part 15 Subpart C, RSS210Power supply: CE, FCC, UL, EN 60950 Operating conditions 0-50 °CHumidity 20 – 80% RH (non-condensing)© 2015 Lorex CorporationAs our product is subject to continuous improvement, Lorex Corporation & subsidiaries reserve the right to modify product design, specifications &Lorex Corporation250 Royal Crest Court Markham, Ontario,901 Elkridge Landing Road, Suite Product InformationLNC226X Wireless HD Outdoor Network Camera UPC7-78597-00226-3Package Weight:0.8 kg / 1.8 lbsPackage Dimensions:(W x D x H)280 x 89 x 191mm / 11 x 3.5 x 7.5”Package Cube:0.0048 CBM x 0.168 CBFContents:Indoor/outdoor camera, Ethernet cable, Power adapter, Quick Setup Guide, CD (user manual included on CD)1. Not intended for submersion in water. Installation in a sheltered location recommended.2. Requires a high speed Internet connection and a wired connection to arouter (not included). An upload speed of 1Mbps is recommended for optimal video performance. Up to 3 devices may connect to the system at the same time. For the latest compatibility list check /support as new models become available in the market.3. Compatible with WPS enabled routers (not included).4. Stated IR illumination ranges are based on ideal conditions in total darkness and typical outdoor night time ambient lighting. Actual range and image clarity depends on installation location, viewing area and light reflection / absorption.5. microSD card not included (supports up to 32GB).6. Connection speed may vary depending Internet bandwidth.7. Additional cameras sold separately.LNC226X DisclaimersLNC226X Dimensions129mm/5.1"92mm/3.6"210/8.3"LNC226XPK2B Wireless HD Outdoor Network Camera, 2 Pack UPC6-95529-00217-0Package Weight: 2.1 kg / 4.8 lbsPackage Dimensions:(W x D x H)304 x 254x 190mm / 12 x 10 x 7.5”Package Cube:0.014 CBM x 0.52 CBFContents:2 x Indoor/outdoor cameras, 2 x Ethernet cables, 2 x Power adapters, Quick Setup Guide, CD (user manual included on CD)1. Compatible with WPS enabled routers (not included).2. Infrared illumination range under ideal conditions. Actual range and clarity may vary depending on scene/object reflection and camera application.3. microSD Card not included (supports up to 32GB).4. Connection speed may vary depending on internet bandwidth.5. Up to 4 simultaneous camera views available on PC, Mac and tablets. Selectable single camera viewing on smartphones.LNC204 DisclaimersLNC204 Dimensions75mm/3.0"35mm/1.4"128mm/5.1"LNC226PK22B Wireless HD Outdoor/Indoor Network Camera, 2 Pack UPC6-95529-00257-6Package Weight: 2.2 kg / 5 lbsPackage Dimensions:(W x D x H)304 x 228 x 228mm / 12 x 9 x 9”Package Cube:0.01 CBM x 0.56 CBFContents:1 x Indoor camera, 1 x Outdoor camera,2 x Ethernet cables, 2 x Power adapters, Quick Setup Guide, CD (user manual included on CD)。

XC2C64A中文资料

XC2C64A中文资料

-
-
-
37
CP56
33
33
45
45
CPG56(1)
33
45
VQ100
-
VQG100(1)
-
-
64
64
-
64
CP132
Байду номын сангаас
-
-
-
-
CPG132(1)
-
-
-
-
TQ144
-
-
-
-
TQG144(1)
-
-
-
-
PQ208
-
-
-
-
PQG208(1)
-
-
-
-
FT256
-
-
-
-
FTG256(1)
-
-
-
-
FG324
-
-
-
-
Table 3: CoolRunner-II CPLD Family Packages and I/O Count
QFG32(1)
XC2C32
XC2C32A 21
XC2C64 -
XC2C64A -
PC44
33
33
33
33
PCG44(1)
33
33
VQ44
33
33
33
33
VQG44(1)
33
33
QFG48(1)
- Hot pluggable
• PLA architecture - Superior pinout retention - 100% product term routability across function block

C2260资料

C2260资料

Pin Connections
1 2 3 4 Voltage Control (Vc) Ground (Case) RF output Supply Voltage Input (Vs)
Marking
C2260-xxxx frequency * C AYYWW
Vectron International ·
Max. 16.5 0.3 5 60
Units pF VDC VDC ns %
Condition
Ordering Code5 RFH
with Vs=3.3V and 15pF load with Vs=3.3V and 15pF load @ (Voh-Vol)/2
50
Frequency Tuning (EFC)
v.2005-12-15 · page 1 of 5 Vectron Asia Pacific Sales Office 1F-2F, No 8 Workshop, No 308 Fenju Road, WaiGaoQiao Free Trade Zone, Pudong, Shanghai, P.R. China 200131 +86 21 5048 0777 tel. +86 21 5048 1881 fax
RF output
Parameter Signal [Standard] Load R || C Output power Min 9 9 0.7 Typ Max. clipped Sinewave 10 11 10 11 Units kΩ pF Vpp Condition > 12.288MHz Ordering Code5 RFC
Weight Processing & Packing

TLC226X_08中文资料

TLC226X_08中文资料

The D packages are available taped and reeled. Add R suffix to device type (e.g., TLC2262CDR). The PW package is available only left-end taped and reeled. Chips are tested at 25°C. TLC2264 AVAILABLE OPTIONS PACKAGED DEVICES TA 0°C to 70°C – 40°C to 125°C – 40°C to 125°C – 55°C to 125°C VIOmax AT 25°C 2.5 mV 950 µV 2.5 mV 950 µV 2.5 mV 950 µV 2.5 mV SMALL OUTLINE (D) TLC2264CD TLC2264AID TLC2264ID TLC2264AQD TLC2264QD — — CHIP CARRIER (FK) — — — — — TLC2264AMFK TLC2264MFK CERAMIC DIP (J) — — — — — TLC2264AMJ TLC2264MJ PLASTIC DIP (N) TLC2264CN TLC2264AIN TLC2264IN — — — — TSSOP (PW) TLC2264CPW TLC2264AIPW — — — — — CERAMIC FLATPACK (W) — — — — — TLC2264AMW TLC2264MW
TLC2262 AVAILABLE OPTIONS PACKAGED DEVICES TA 0°C to 70°C – 40°C to 125°C – 40°C to 125°C – 55°C to 125°C VIOmax AT 25°C 2.5 mV 950 µV 2.5 mV 950 µV 2.5 mV 950 µV 2.5 mV SMALL OUTLINE (D) TLC2262CD TLC2262AID TLC2262ID TLC2262AQD TLC2262QD — — CHIP CARRIER (FK) — — — — — TLC2262AMFK TLC2262MFK CERAMIC DIP (JG) — — — — — TLC2262AMJG TLC2262MJG PLASTIC DIP (P) TLC2262CP TLC2262AIP TLC2262IP — — — — TSSOP (PW) TLC2262CPW TLC2262AIPW — — — — — CERAMIC FLATPACK (U) — — — — — TLC2262AMU TLC2262MU

PLT空压机控制器及功能介绍

PLT空压机控制器及功能介绍
深圳市普乐特电子有限公司
8/29
2 开关量输出为继电器输出,如下图所示:
继电器输出为一组常开触点,触点通常为AC250V/5A.
深圳市普乐特电子有限公司
9/29
3 模拟量输入:温度
电阻型温度传感器为PT100或PT1000,如图所示:
其中,PT100电阻值在0℃时为100Ω ,100℃时为138.5Ω ,也就是温度变 1℃,电阻变化1.385Ω ;同理,PT1000电阻值在0℃时为1000Ω , 100℃ 时为1385Ω 。所以PT100和PT1000不能混用。
主机:通信编号为001,联动参数中,联动状态设为主机的空压机。网络中只允许有一台空压机为主机。主机需
设联动机数,联动压力上限,联动压力下限。联动延时等参数。
从机:通信编码为002-016。联动参数中需设置联动状态为从机的空压机。网络中不允许有编码相同的从机。 联动压力下限:在主机的联动参数中设置,联动控制中,当主机的供气压力小于此值时,若网络中还有处于
………
1号机 主机
2号机 从机
3号机 从机
4号机 ……… N号机
从机
从机
深圳市普乐特电子有限公司
22/29
计算机监控网络结构示意图如下图所示:
………
1号机
2号机
3号机
4号机 ……… N号机
深圳市普乐特电子有限公司
23/29
计算机、触摸屏监控网络结构示意图如下图所示:
………
1号机
2号机
3号机
4号机 ……… 8号机
3/29 点击产品型号可出现相应产品图片
深圳市普乐特电子有限公司
4/29

KY02S/MAM-100 KY02S VF3/MAM-100C KY02S/MAM-200 KY02S VF3/MAM-200C KY12S/MAM-260 KY12S/MAM-280 KY16S/MAM-100 KY16S/MAM-200 KY08S/MT6070IH KY08S/MT6070IP KY18S/MT6070IH KY18S/MT6070IP

罗莱弗SLX系列6x6厘米中型大格SLR摄影机说明书

罗莱弗SLX系列6x6厘米中型大格SLR摄影机说明书
Shutter:
Between the lens shutter, 1/500 to 30 sec., and B; speed set by user and electronically controlled via control pulses from computer in camera body.
With its 120/220 film capability, easy-load film cassettes, quickcharge Nicad battery (good for up to 1000 exposures per charge) high quality Carl Zeiss and Zeissdesigned lenses, and its wide range of accessories, the SLX has all the features even the most demanding professional could want.
Cat. No. 201·112
SLX body only, with battery, body cap and strap.
Cat. No. 201·110
~ollei
SLX 6x6cm Single Lens Reflex Camera
1. Film transport wheel 2. Symbol for film positioning 3. Release button for camera back, right
lens hoods; HFT® multicoating for reduced flare and better color rendition . Accessory lenses from 40mm to 350mm available.

LNK626PG电源IC中文资料要点

LNK626PG电源IC中文资料要点

LNK626PG 电源IC中文资料LNK623-626 LinkSwitch-CV产品系列 September 2009 带初级侧精确恒压(CV)控制的高能效、离线式开关IC产品特色:大大简化恒压转换器的设计•省去光耦器和所有次级侧恒压控制电路•省去偏置绕组电源-IC自偏置先进的性能特性:补偿外围元件的温度漂移•专利的IC参数调整技术使得IC参数的公差非常严格•连续和/或非连续导通模式工作,增强设计灵活性•频率调制技术极大降低了EMI滤波元件的成本•通过外部电阻的选择/调节实现更严格的输出容差。

先进的保护/安全特性:自动重启动保护功能在输出短路及控制环路故障(元件开路和短路)状况下可将输出功率降低95%以上•迟滞热关断–自动恢复功能可降低电源从故障现场的回收•无论在PCB板上还是在封装上,都保证高压漏极与其它所有引脚之间满足高压爬电要求。

EcoSmart® –高效节能:在230 V AC输入条件下空载功耗低于200 mW,使用可选外部偏置绕组时可低于70 mW •无需增加任何元件,轻松满足全球所有的节能标准•开/关控制可在极轻负载时具备恒定的效率–是达到强制性EISA 和能源之星2.0标准的理想选择•无需初级或次级电流检测电阻,即可提高效率。

绿色封装:无卤素和符合RoHS要求的封装。

应用:DVD/机顶盒•适配器•待机及辅助电源•家用电器、白色家电和消费电子产品•工业控制。

描述:LinkSwitch-CV采用了革新的控制技术,无需光耦器和次级恒压控制电路,且能提供极为严格的输出电压调节,因此可大大简化低功率恒压(CV)转换器的设计。

专利的IC参数调整技术与E-Shield™变压器结构技术的完美结合,令使用LinkSwitch-CV LNK623/4进行Clampless™设计成为可能。

图1. 典型应用电路图(a)及输出特性包络(b) *可选用LNK623-624PG/DG。

(有关箝位及其他外部电路设计的注意事项,请参阅“主要应用指南”部分)LinkSwitch-CV*Wide RangeHV DC InputPI-5195-080808DSFBBP(a) Typical Application Schematic(b) Output CharacteristicIOVO±5%Auto-RestartPI-5196-080408LinkSwitch-CV能够对多路输出反激式电源应用(如DVD和机顶盒)提供出色的交叉稳压。

Versadrive SC-26 发射器管理系统说明书

Versadrive SC-26 发射器管理系统说明书
16.Do not install this apparatus in a confined space such as a book case or similar unit. Good ventilation should be maintained around the apparatus. Any vents, air-inlets or fans should not be obstructed by objects such as paper, table-cloths, curtains etc.
18.WARNING: The mains plug/appliance coupler is used as a disconnect device, the disconnect device shall remain readily operable.
ATTENTION: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR
Versadrive SC-26 Speaker Management System OPERATING MANUAL AND USER GUIDE

Table Of Contents
Table Of Contents...................................................................................... 1 Important Warnings & Safety Instructions.................................................. 2 Editing Audio Settings................................................................................ 4 Editing System Settings............................................................................. 5 PC Software Operation.............................................................................. 6 Specifications............................................................................................. 9 Warranty................................................................................................... 10

LNK626 中文资料

LNK626 中文资料
先进的保护/安全特性 • 自动重启动保护功能在输出短路及控制环路故障(元件开路和
短路)状况下可将输出功率降低95%以上 • 迟滞热关断 – 自动恢复功能可降低电源从故障现场的回收 • 无论在PCB板上还是在封装上,都保证高压漏极与其它所有引
脚之间满足高压爬电要求
EcoSmart® – 高效节能 • 在230 VAC输入条件下空载功耗低于200 mW,使用可选外部
除了上述触发自动重启动的情况外,在工作周期的正激期间 (开关导通时间),如果检测到反馈引脚电流低于120 μA,转换
器会将此“报告”为开环故障(电位分压器的顶部电阻开路或 丢失),并将自动重启动时间从200 ms降低到大约6个时钟周期 (90 μs),同时使禁止周期维持在2.5秒。这样可以将自动重启动占 空比减小到0.01 %以下。
偏置绕组时可低于70 mW • 无需增加任何元件,轻松满足全球所有的节能标准 • 开/关控制可在极轻负载时具备恒定的效率 – 是达到强制性EISA
和能源之星2.0标准的理想选择 • 无需初级或次级电流检测电阻,即可提高效率
绿色封装 • 无卤素和符合RoHS要求的封装
应用 • DVD/机顶盒 • 适配器 • 待机及辅助电源 • 家用电器、白色家电和消费电子产品 • 工业控制
2
Rev. B 11/08

LNK623-626
LinkSwitch-CV功能描述
LinkSwitch-CV在一个器件上集成了一个高压功率MOSFET开关 及一个电源控制器。与LinkSwitch-LP和TinySwitch-III相似, 它使用开/关控制方式来调节输出电压。LinkSwitch-CV控制器 包括一个振荡器、反馈(检测及逻辑)电路、6 V稳压器、过热 保护、频率调制、电流限流电路、前沿消隐功能以及用于恒压 控制的开/关状态机。

SC2446资料

SC2446资料

Parameter
Symbol
Maximum Ratings
Units
Supply Voltage For Step-Down Controllers
AVCC, PVCC
-0.3 to 20
V
Input Voltage For the Second Converter High-Side Driver Supply Voltages
Exceeding the specifications below may result in permanent damage to the device, or device malfunction. Operation outside of the parameters specified in the Electrical Characteristics section is not implied.
元器件交易网
SC2446
Dual-Phase Single or Two Output Synchronous Step-Down Controllers
POWER MANAGEMENT
Description
The SC2446 is a high-frequency dual synchronous stepdown switching power supply controller. It provides outof-phase high-current output gate drives to all N-channel MOSFET power stages. The SC2446 operates in synchronous continuous-conduction mode. Both phases are capable of maintaining regulation with sourcing or sinking load currents, making the SC2446 suitable for generating both VDDQ and the tracking VTT for DDR applications. The SC2446 employs fixed frequency peak current-mode control for the ease of frequency compensation and fast transient response. The dual-phase step-down controllers of the SC2446 can be configured to provide two individually controlled and regulated outputs or a single output with shared current in each phase. The Step-down controllers operate from an input of at least 4.7V and are capable of regulating outputs as low as 0.5V The step-down controllers in the SC2446 have the provision to sense a synthesized MOSFET RDS(ON) for current-mode control. This sensing scheme (U.S. patent 6,441,597) eliminates the need of the current-sense resistor and is more noise-immune than direct sensing of the high-side or the low-side MOSFET voltage. Precise current-sensing with sense resistor is optional. Individual soft-start and overload shutdown timer is included in each step-down controller. The SC2446 implements hiccup overload protection. In two-phase singleoutput configuration, the master timer controls the softstart and overload shutdown functions of both controllers.

施耐德低压断路器说明书 - Compact NSX, Easypact CVS, Easypact

施耐德低压断路器说明书 - Compact NSX, Easypact CVS, Easypact

Low Voltage Circuit Breaker 1 to 1600ACompact NSX 100 /160/250Compact NSX 400/630Compact NS 800 to 1600Easypact CVS 160/250Easypact CVS 400/630Easypact EZC 100Acti 9Low Voltage Circuit Breakers 1 to 1600 APageActi 92681226344256Easypact EZC 100Easypact CVS 160 to 630Compact NSX 100 to 630Compact NS 800 to 1600Accessories OverviewTripping Curves Dimensions and Mounting Secection TableSelection table -Acti 9Acti9Vigi iC60漏電保護模組應用技術資料Vigi iC60漏電模組內含殘餘電流電磁機械動作方式,無須輔助電源。

額定電流:動作時間重量(g)接線小於25A :電纜最大可接至25mm 22P 斷路器3P 斷路器組合示意圖2P Vigi 模組3P Vigi 模組小於63A :電纜最大可接至35mm 225A 145 63A165 25A 184 63A 210符合IEC61008/61009跳脫時間(Triping time)與漏電電流(I Δn)關係如下:Vigi iC60 漏電模組內含濾波裝置,可有效防止由於瞬間電壓變化。

(照明或設備產生線路電壓波動…)和突波電流所引起的誤動作。

Vigi iC60漏電模組適用63A 及63A 以下的iC60 系列斷路器Vigi iC60漏電模組(額定電流)選定可向下相容:Ex. Vigi iC60 ≦40A 可直接搭配 Acti-9 iC60N MCB 40A 或40A 以下。

Eaton Moeller 系列 CI 保险组合封闭型 263526 产品说明书

Eaton Moeller 系列 CI 保险组合封闭型 263526 产品说明书

Eaton 263526Eaton Moeller® series CI Insulated enclosure, IP55_x, rotary handle black grey, for PKZ0 CI-PKZ0-GVMGeneral specificationsEaton Moeller® series CI Insulated enclosure263526126 mm158 mm 80 mm 0.2 kg CECI-PKZ0-GVMProduct NameCatalog Number Product Length/Depth Product Height Product Width Product Weight Compliances Model Code0 AAccessoriesIs the panel builder's responsibility. The specifications for the switchgear must be observed.0 W10 WMeets the product standard's requirements.Is the panel builder's responsibility. The specifications for the switchgear must be observed.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Black-gray rotary knobPE(N) terminalMeets the product standard's requirements.Meets the product standard's requirements.Is the panel builder's responsibility.Is the panel builder's responsibility.IP55NEMA Other DA-CE-ETN.CI-PKZ0-GVMIL03407019ZDA-CD-ci_pkz0_gvmDA-CS-ci_pkz0_gvmeaton-manual-motor-starters-enclosure-ci-insulated-enclosure-dimensions.epseaton-manual-motor-starters-mounting-ci-insulated-enclosure-dimensions-002.epseaton-manual-motor-starters-enclosure-ci-k-accessory-dimensions-002.epseaton-manual-motor-starters-enclosure-ci-insulated-enclosure-3d-drawing-003.epsRated operational current for specified heat dissipation (In) Product category10.11 Short-circuit ratingEquipment heat dissipation, current-dependent PvidHeat dissipation capacity Pdiss10.4 Clearances and creepage distances10.12 Electromagnetic compatibility10.2.5 Lifting10.2.3.1 Verification of thermal stability of enclosuresFitted with:10.2.3.2 Verification of resistance of insulating materials to normal heat10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects10.8 Connections for external conductors10.9.2 Power-frequency electric strengthDegree of protection eCAD model Installeringsinstruksjoner mCAD model TegningerAmbient operating temperature - max70 °C10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.Static heat dissipation, non-current-dependent Pvs0 W10.9.3 Impulse withstand voltageIs the panel builder's responsibility.Enclosure materialPlasticKnockouts2 x M25 (cable entry knockout with thread at the top)Hard mirror with cable entry knockouts (can be cut out)2 x M25 (cable entry knockout with thread at the bottom)2 x M20 (cable entry knockouts at the rear)Ambient operating temperature - min-25 °C10.2.2 Corrosion resistanceMeets the product standard's requirements.10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.10.2.4 Resistance to ultra-violet (UV) radiationPlease enquire10.2.7 InscriptionsMeets the product standard's requirements.10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.Used with+ U or A, +L-PKZ0 (2 units), PKZM0-… and VHIModelSurface mounting10.13 Mechanical functionThe device meets the requirements, provided the information inEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. Med enerett.Eaton is a registered trademark.All other trademarks are property of their respectiveowners./socialmediathe instruction leaflet (IL) is observed.Does not apply, since the entire switchgear needs to be evaluated.Is the panel builder's responsibility.Does not apply, since the entire switchgear needs to be evaluated.0 W10.2.6 Mechanical impact10.9.4 Testing of enclosures made of insulating material 10.3 Degree of protection of assembliesHeat dissipation per pole, current-dependent Pvid。

Mettler Toledo XP26微衡仪用户说明书

Mettler Toledo XP26微衡仪用户说明书

NewsWeighing and Analysis in the Laboratory1Machinery PlasticsElectronicsDiverse Tasks, One GoalHella KGaA Hueck & Co. runs its world-wide single chemical laboratory in Lipp-stadt, Germany. The site copes with an en-tire spectrum of the most diverse samples. The items which land on Peter Broske’s desk include complete headlight assem-blies, complex electronic components, circuit boards, single microchips, gran-ules, production containers and samples for air and water analysis for environ-mental protection and safety at work. Apart from in-process quality control, the lab also conducts analysis alongside the development of new products. It is also the central point of contact for troubleshoot-ing within production, processes and in the field.In the laboratory of Hella KGaA Hueck & Co., the daily routine of testing diverse samples used in the automotive industry is now greatly simpli-fied and far more efficient with the employment of METTLER TOLEDO’s XP26 microbalance. Peter Broske, head of the measurement and test centre in the chemical analytics division of Hella KGaA Hueck & Co. is very enthusiastic about this new purchase. Turning Up the Lights for a Real Problem SolverEfficient operations, high throughput, user-friendliness and flexible deployment of the relevant equipment are therefore essential. In addition, the automotive industry sets tight constraints in respect to accuracy, reproducibility and deadline adherence, in order to greatly reduce the risk of handling errors. Peter Broske ex-plains how well the XP26 microbalance from METTLER TOLEDO meets these requirements and shares some practical examples with us.Difficult Sample Handling Solved by Smart SolutionsFogging tests are now standard practice in the automotive industry, which is still by far the primary customer segment for Hella. These tests involve studying the2METTLER TOLEDO Machinery, Plastics & Electronics News 1PublisherMettler-Toledo AGLaboratory & Weighing Technologies Im LangacherCH-8606 Greifensee, Switzerland ProductionSegment Marketing LAB SwitzerlandTechnical articles Mettler-Toledo AG– Laboratory & Weighing Technologies – Analytical Instruments 11794274 40.12Subject to technical changes. © Mettler-Toledo AG 08/01 Printed in Switzerland.X P 26 M i c r o b a l a n c eemission of water, organic solvents, ad-ditives and plasticisers from components and assemblies. To perform the test the sample is heated and the volatile compo-nents are condensed onto a thin piece of cooled aluminum foil. These delicate foils are 50 - 80 mm in diameter and must not be bent or folded while determining tare weight, sample taking or back weighing. “The sensitivity and the size of the foil is the problem here”, explained Broske, just one crease or fold is enough to destroy the airtight seal between the sample and the sample holder. The luminous reflectance of the folded edges would prevent any sub-sequent visual inspection of the conden-sates intended to determine their reflec-tance or impede any direct analysis under the FTIR microscope. This problem was solved thanks to the XP microbalance’s large weighing chamber and the hanging support of the weighing pan, situated at the rear of the weighing chamber”.The grid-type weighing pan can be eas-ily removed and replaced with ErgoClips. The ErgoClip is a modified weighing pan tailor-made to the individual needs of fre-quently used tare containers (e.g. volu-metric flasks or Eppendorf tubes). In the case of fogging tests on aluminum foil, Mr. Broske helped to find an optimum solution with his own modified version of the ErgoClip micro basket.Peter Broske, head of the mea-surement and test centre in the chemical analytics division of Hella KGaA Hueck & CoMr. Broske also benefits from the bal-ance’s application software: “The dif-ferential weighing application in the balance enables us to rule out any errors occurring during manual notation of the tare weights. That’s a major plus!”3METTLER TOLEDO Machinery, Plastics & Electronics News 1Full Independency Thanks to METTLER TOLEDOMr. Broske sums up the advantages of the XP microbalance:n Large weighing area and high degreeof flexibility, thanks to SmartGrid and the ErgoClipsn High accuracy for small samples and up to 52 grams with the possibility of directly weighing into various tare vesselsn Differential weighing application accelerates work rate and lowers error riskn Short settling times and stable results within seconds thanks to the well-pro-tected weighing chamber with exter-nal/internal draft shields and unique hanging SmartGrid weighing pan n Automatic door opening facilitatesand accelerates operation procedureThe microbalance in its surroundings at the analytical laboratory at Hella.Intelligent grid-type weighing pan and up to 52 g extra weighing area allow direct weighing into a wide and diverse range of tare vessels - illustrated here with thermodesorption tube.High-precision sample weighing up to 0.2 mg, illustrated here with a scratched coating on a polymer component.Modified ErgoClipHe summarizes: “Given the constantly growing number and diversity of tasks and the required accuracy and reproduc-ibility, we would have had to outsource tests to other laboratories. But these labo-ratories do not share our material and process know-how. Therefore, not only would it be expensive but also extremely questionable in terms of the quality and significance of the results. The XP26 mi-crobalance is definitely the best invest-ment and overall solution.”} /micro。

atc中文手册

atc中文手册
概述
CAT24WC256 是一个256K 位串行CMOS E2PROM 内部含有32768 个字节每字节为8 位
CATALYST 公司的先进CMOS 技术实质上减少了器件的功耗CAT24WC256 有一个64 字节页写缓冲器
该器件通过I2C 总线接口进行操作
管脚描述
管脚名称 功能
A0 A1 地址输入
置在接收到第一个数据字节后不发送应答信号从而避免寄存器区域被编程改写
读操作
CAT24WC256 读操作的初始化方式和写操作时一样仅把R/W 位置为1 有三种不同的读操作方式
立即/当前地址读选择/随机读和连续读
立即/当前地址读
的地址计数器内容为最后操作字节的地址加1 也就是说如果上次读/写的操作地址为N 则立即
2 在数据传送过程中当时钟线为高电平时数据线必须保持稳定状态不允许有跳变时钟线
为高电平时数据线的任何电平变化将被看作总线的起始或停止信号
起始信号
时钟线保持高电平期间数据线电平从高到低的钟线保持高电平期间数据线电平从低到高的跳变作为I2C 总线的停止信号
器件寻址
主器件通过发送一个起始信号启动发送过程然后发送它所要寻址的从器件的地址8 位从器件地
址的高5 位固定为10100 见图5 接下来的2 位A1 A0 为器件的地址位最多可以连接4 个器件
到同一总线上这些位必须与硬连线输入脚A1 A0 相对应从器件地址的最低位作为读写控制位1
表示对从器件进行读操作0 表示对从器件进行写操作在主器件发送起始信号和从器件地址字节后
读的地址从地址N+1 开始如果N=E 此处E=32767 则计数器将翻转到0 且继续输出数据CAT24WC256
接收到从器件地址信号后R/W 位置1 它首先发送一个应答信号然后发送一个8 位字节数据主

LNK626PG电源IC中文资料

LNK626PG电源IC中文资料

LNK626PG 电源IC中文资料LNK623-626 LinkSwitch-CV产品系列 September 2009 带初级侧精确恒压(CV)控制的高能效、离线式开关IC产品特色:大大简化恒压转换器的设计•省去光耦器和所有次级侧恒压控制电路•省去偏置绕组电源-IC自偏置先进的性能特性:补偿外围元件的温度漂移•专利的IC参数调整技术使得IC参数的公差非常严格•连续和/或非连续导通模式工作,增强设计灵活性•频率调制技术极大降低了EMI滤波元件的成本•通过外部电阻的选择/调节实现更严格的输出容差。

先进的保护/安全特性:自动重启动保护功能在输出短路及控制环路故障(元件开路和短路)状况下可将输出功率降低95%以上•迟滞热关断–自动恢复功能可降低电源从故障现场的回收•无论在PCB板上还是在封装上,都保证高压漏极与其它所有引脚之间满足高压爬电要求。

EcoSmart® –高效节能:在230 V AC输入条件下空载功耗低于200 mW,使用可选外部偏置绕组时可低于70 mW •无需增加任何元件,轻松满足全球所有的节能标准•开/关控制可在极轻负载时具备恒定的效率–是达到强制性EISA 和能源之星2.0标准的理想选择•无需初级或次级电流检测电阻,即可提高效率。

绿色封装:无卤素和符合RoHS要求的封装。

应用:DVD/机顶盒•适配器•待机及辅助电源•家用电器、白色家电和消费电子产品•工业控制。

描述:LinkSwitch-CV采用了革新的控制技术,无需光耦器和次级恒压控制电路,且能提供极为严格的输出电压调节,因此可大大简化低功率恒压(CV)转换器的设计。

专利的IC参数调整技术与E-Shield™变压器结构技术的完美结合,令使用LinkSwitch-CV LNK623/4进行Clampless™设计成为可能。

图1. 典型应用电路图(a)及输出特性包络(b) *可选用LNK623-624PG/DG。

(有关箝位及其他外部电路设计的注意事项,请参阅“主要应用指南”部分)LinkSwitch-CV*Wide RangeHV DC InputPI-5195-080808DSFBBP(a) Typical Application Schematic(b) Output CharacteristicIOVO±5%Auto-RestartPI-5196-080408LinkSwitch-CV能够对多路输出反激式电源应用(如DVD和机顶盒)提供出色的交叉稳压。

XS SC26-2安全控制器快速入门指南说明书

XS SC26-2安全控制器快速入门指南说明书

XS/SC26-2 Safety ControllerQuick Start GuideOrigianl Document 174869 Rev. D 5 January 2017About this GuideThis guide is designed to help you create a sample con fi guration for the XS/SC26-2 Safety Controller using the XS26-2 Expandable Safety Controller PC Interface. For complete information on mounting, device installation and operation, commissioning checkout procedures, product speci fi cations, troubleshooting, and glossary, please refer to the Safety Controller Instruction Manual (p/n 174868) and support documentation for individual safety input and output devices. Use of this document assumes familiarity with pertinent safety standards and practices as outlined in the Instruction Manual.Product OverviewDesigning a Sample Confi gurationThe confi guration process used in this guide provides basic understanding of the software features that are necessary to create a confi guration for any application. The example confi guration is based on a sample application which makes use of the following devices: an XS/SC26-2 Safety Controller, an E-stop button, a Safety Light Curtain, an Interlocked Gate Switch, and a Manual Reset. The illustration below depicts thesedevices and additional safety equipment for a sample Robotic Cell application. - Tel: +1-763-544-3164P/N 148770 Rev. FSoftware InstallationThe XS26-2 Expandable Safety Controller PC Interface can be downloaded from/xs26.Important: Administrative rights are required to install the Safety Controller drivers (needed forcommunication with the controller).To install the software from the Banner Engineering website:1. Download the latest version of the software from /xs26.2. Navigate to and open the downloaded fi le.3. Click Next to begin the installation process.4. Confi rm the software destination and availability for users and click Next.5. Click Next to install the software.6. Depending on your system settings, a popup window may appear prompting to allow XS26-2 ExpandableSafety Controller to make changes to your computer. Click Yes.7. Click Close to exit the installer.Open XS26-2 Expandable Safety Controller from the Desktop or the Start Menu.1. Windows is a registered trademark of Microsoft Corporation in the United States and/or other countries. - Tel: +1-763-544-31643 P/N 148770 Rev. FDesigning a Confi gurationOpen XS26-2 Expandable Safety Controller from the Desktop or the Start Menu.PC Interface Features - Tel: +1-763-544-3164P/N 148770 Rev. F1 Navigation ToolbarStarts a New Project or opens a Recent projectand Sample Confi gurations Displays Password ManagerOpens an existing project Reads data, such as Fault Log, Confi guration, Network Settings, and Device Information, from the Safety ControllerSaves (or Saves As) the project to the user-defi ned location Writes the data, such as Confi guration and/or Network Settings, to the Safety ControllerPrints a customizable Confi guration Summary Makes the Live Mode view availableReverts up to ten previous actions Makes the Simulation Mode View availableRe-applies up to ten previously reverted actions Indicates SC-XM2 drive connectionDisplays Network Settings Opens the Help optionsDisplays Project Settings2 Tabs• Equipment—displays an editable view of all connected equipment.• Functional View—provides an editable iconic representation of the control logic.• Wiring Diagram—displays the I/O device wiring detail for use by the installer.• Ladder Logic—displays a symbolic representation of the Controller’s safeguarding logic for the use by the machine designer or controls engineer.• Industrial Ethernet (when enabled)—displays editable network confi guration options.• Confi guration Summary—displays a detailed confi guration summary.• Live Mode (when enabled)—displays the live mode data, including current faults.• Simulation Mode (when enabled)—displays the simulation mode data3 Selected viewDisplays the view corresponding to the selected tab (Equipment view shown).4 Module SummaryDisplays the Base Controller and any connected modules.5 ChecklistProvides action items to confi gure the system and correct any errors to successfully complete theconfi guration.6 PropertiesDisplays the properties of the selected device, function block, or connection (properties cannot be edited in this view, click Edit to make changes).5 - Tel: +1-763-544-3164P/N 148770 Rev. FDefi ne the Project Settings Click Project Settings.Enter the information about the project: Confi guration NameName of the confi guration; displayed on the controller (models with display); diff erent from fi le name.ProjectProject name is useful for distinguishing between various application areas. AuthorPerson designing the confi guration. NotesSupplemental information for thisconfi guration or project.Project DateDate pertaining to the project. Add Equipment1. On the Equipment view select yourBase Module properties (Display,Industrial Ethernet, Expandability) by either double-clicking the module orclicking the Edit under the propertiestable when the module is selected.2. Add Safety Input devices by clickingunder the Base Module:• Emergency Stop• Gate Switch• Optical SensorNote: For the purpose of thisconfi guration default device propertiesare used. - Tel: +1-763-544-3164P/N 148770 Rev. F7 - Tel: +1-763-544-3164P/N 148770 Rev. F 3. Add Non-Safety Inputs by clickingunder the Base Module:• Manual ResetCreate Connections4. Go to Functional View .Note: The Check List on the left lists any missing connections that need to be added before the con figuration is valid.5. Add the Function Blocks by clicking on one of the empty placeholders in the middle area:• Latch Reset Block - Tel: +1-763-544-3164P/N 148770 Rev. F6. Add Logic Blocks by clicking on one of the empty placeholders in the middle area:• And7. For this con fi guration, increase the number of Input Nodes to “3”.8. Connect Optical Sensor , Gate Switch , and Latch Reset Block to one of the input nodes on the AND block.9. Connect Emergency Stop and Manual Reset to the Latch Reset Block .10. Connect the AND block to the Solid State Output (SO1).Note: You may re-arrange any of the Equipment blocks or Functional Elements blocks for a better visual representation of the connections. Solid State Outputblocks cannot be moved.© Banner Engineering Corp. All rights reserved.Banner Engineering Corp Limited WarrantyBanner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.This Warranty is exclusive and limited to repair or , at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identi fi ed as not intended for such purposes will void the product warranty. Any modi fi cations to this product without prior express approval by Banner Engineering Corp will void the product warranties. All speci fi cations published in this document are subject to change; Banner reserves the right to modify product speci fi cations or update documentation at any time. Speci fi cations and product information in English supersedes that which is provided in any other language. For the most recent version of any documentation, refer to: .Save the Con fi guration1. Click Save .2. Select Save As .3. Navigate to the folder where you wish to save your con fi guration.4. Name the fi le (may be the same or di ff erent from the Con fi guration name).5. Click Save.Con fi rm the Con fi guration1. Power the Safety Controller and connect it to the PC using the appropriate USB cable.2. Click Send to Controller .3. Enter the password (the default password is 1901).4. Click Continue to enter the con fi g-mode.5. After the Reading Con fi guration from the Controller process is completed, the Con fi rm Con fi guration screen opens. Verify that the con fi guration is correct.6. Scroll to the end of the con fi guration and click Con fi rm .7. After the Send Con fi guration To Controller process has completed, click Close .8. Reset the Safety Controller for the changes to take e ffect.It is the responsibility of the Qualifi ed Person who con fi gures, installs, or maintains the XS26-2 Safety Controller to:• Carefully read, understand, and follow the information in the XS26-2 manual (which can be accessed via the drop-down Help menu of the PC Interface)• Perform a risk assessment of the speci fi c machine guarding application• Determine what safeguarding devices and methods are appropriate per the requirements de fi ned in ISO 13849-1 and those referenced in the XS26-2 manual• Create and con fi rm each XS26-2 con fi guration and then verify that the entire safeguarding system (including input devices and output devices) is operational and working as intended• Periodically re-verify, as needed, that the entire safeguarding system is working as intendedFailure to follow any of these recommendations may potentially create a dangerous condition that may lead to serious injury or death.。

TLP3526中文资料

TLP3526中文资料

1.0
1.4
1.8
2.2
2.6
Pulse forward voltage VFP (V)
4
2002-09-25
元器件交易网
Trigger LED current IFT (arbitrary unit)
Peak off-state current IDRM (arbitrary unit)
元器件交易网
TL(Ta = 25°C)
Characteristic
Symbol
Rating
Unit
Forward current
Forward current derating (Ta ≥ 53°C)
LE D
Peak forward current (100µs pulse, 100pps)
Characteristic Trigger LED current Capacitance (input to output) Isolation resistance
Isolation voltage
Fig.1: dv / dt test circuit
Symbol IFT CS RS
BVS
Test Condition
VT = 6V VS = 0, f = 1MHz VS = 500V AC, 1 minute AC, 1 second, in oil DC, 1 minute, in oil
Min.

― 5×1010 2500
― ―
Typ.

1.5 1014 ― 5000 5000
Max. 10 ―
― ― ― ―
1 5 125 600 1.0 0.7 -14.3

MC2716 技术规格书

MC2716 技术规格书

CDMA2000 1xEVDO Rev. A 网络下 800MHz: 824~849MHz 1900MHz: 1850 ~ 1910 MHz 800MHz: ±300Hz 1900MHz: ±150Hz 800MHz: 23dBm~30dBm@-105.5dBm 1900MHz: 18dBm~27dBm@-105.5dBm <-50dBm@-25dBm <-61dBm ±1.0µs >0.944 ( Test 1: -25dBm/1.23MHz) -48.3dBm/1.23MHz±9.5dB (Test 2: -65dBm/1.23MHz) -8.3dBm/1.23MHz±9.5dB (Test 3: -93.5dBm/1.23MHz) 20.3dBm /1.23MHz±9.5dB -42dBc/30KHz or -54dBm/1.23MHz(|Δf|: 885KHz~1.98MHz)
42 44 38 36 22 20 14 12 10 8 49 15 18 21 26 27 29 34 35 37 40 43 50 1 3 5 6 7 11 13 17 19 16 23 25 28 30 31 32 33 45 46 47 48 49 51
信号名称 +3.3V
LED_WWAN_N LED_WLAN_N
接收灵敏度 接收信号范围 单音抗干扰度 双音互调杂散
-105.5dBm@FER=0.5% -25dBm~ -105.5dBm@FER≤0.5% FER≤1.0%(-102.4dBm/BW,-30dBm@±900KHz) FER≤1.0%(Test1: -102.4dBm/BW, +900/+1700KHz, -43dBm)
3 外观和结构
项目

22mm-26mm 电子配件说明书

22mm-26mm 电子配件说明书

Exhibit 8.1
Jurisdiction of Incorporation
Cayman Islands Cayman Islands Hong Kong United States Hong Kong Hong Kong Hong Kong United States United States United States United States Malaysia United States Hong Kong Malaysia China China China China China China China China China China China China China China China China China China
List of Subsidiaries as of March 15, 2017*
Company Name
Xinyuan Real Estate, Ltd. Xinyuan International Property Investment Co., Ltd. Xinyuan International (HK) Property Investment Co., Limited XIN Development Group International Inc. South Glory International Ltd. Victory Good Development Ltd. Elite Quest Holdings Ltd. XIN Irvine, LLC Vista Sierra, LLC XIN Development Management East, LLC XIN NY Holding, LLC XIN Eco Marine Group Properties Sdn Bhd 421 Kent Development, LLC Xinyuan Sailing Co., Ltd. AWAN Plasma Sdn. Bhd. Zhengzhou Yasheng Construction Material Co., Ltd. Zhengzhou Jiasheng Real Estate Co., Ltd Zhengzhou Yusheng Landscape Design Co., Ltd. Xinyuan (China) Real Estate, Ltd. Beijing Yue-Mart Commerce and Trade Co., Ltd. Henan Xinyuan Real Estate Co., Ltd. Xi'an Xinyuan Metropolitan Business Management Co., Ltd. Tianjin Xinyuan Real Estate Co., Ltd. Changsha Xinyuan Wanzhuo Real Estate Co., Ltd. Beijing Xinleju Technology Development Co., Ltd. Henan Yue-Mart Commerce and Trade Co., Ltd. Qingdao Xinyuan Xiangrui Real Estate Co., Ltd. Shandong Xinyuan Real Estate Co., Ltd. Zhengzhou Hengsheng Real Estate Co., Ltd. Zhengzhou Mingyuan Landscape Engineering Co., Ltd. Zhengzhou Xinyuan Computer Network Engineering Co., Ltd. Henan Xinyuan Wanzhuo Real Estate Co., Ltd. Suzhou Xinyuan Real Estate Development Co., Ltd.
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

Vn VN – Equivalent Input Noise Voltage – nV/ Hz nv//Hz
50
VDD = 5 V RS = 20 Ω TA = 25°C40源自302010
The TLC226x, exhibiting high input impedance 0 and low noise, are excellent for small-signal 10 102 103 104 conditioning for high-impedance sources, such as f – Frequency – Hz piezoelectric transducers. Because of the micropower dissipation levels, these devices work well Figure 1 in hand-held monitoring and remote-sensing applications. In addition, the rail-to-rail output feature with single or split supplies makes this family a great choice when interfacing with analog-to-digital converters (ADCs). For precision applications, the TLC226xA family is available and has a maximum input offset voltage of 950 µV. This family is fully characterized at 5 V and ± 5 V. The TLC2262/4 also makes great upgrades to the TLC27M2/L4 or TS27M2/L4 in standard designs. They offer increased output dynamic range, lower noise voltage and lower input offset voltage. This enhanced feature set allows them to be used in a wider range of applications. For applications that require higher output drive and wider input voltage range, see the TLV2432 and TLV2442. If your design requires single amplifiers, please see the TLV2211/21/31 family. These devices are single rail-to-rail operational amplifiers in the SOT-23 package. Their small size and low power consumption, make them ideal for high density, battery-powered equipment.
EQUIVALENT INPUT NOISE VOLTAGE vs FREQUENCY
60
description
The TLC2262 and TLC2264 are dual and quadruple operational amplifiers from Texas Instruments. Both devices exhibit rail-to-rail output performance for increased dynamic range in single- or split-supply applications. The TLC226x family offers a compromise between the micropower TLC225x and the ac performance of the TLC227x. It has low supply current for battery-powered applications, while still having adequate ac performance for applications that demand it. The noise performance has been dramatically improved over previous generations of CMOS amplifiers. Figure 1 depicts the low level of noise voltage for this CMOS amplifier, which has only 200 µA (typ) of supply current per amplifier.
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
元器件交易网
TLC226x, TLC226xA Advanced LinCMOS™ RAIL-TO-RAIL OPERATIONAL AMPLIFIERS
SLOS177A – FEBRUARY 1997 – REVISED JULY 1999
D D D D D D
Output Swing includes Both Supply Rails Low Noise . . . 12 nV/√Hz Typ at f = 1 kHz Low Input Bias Current . . . 1 pA Typ Fully Specified for Both Single-Supply and Split-Supply Operation Low Power . . . 500 µA Max Common-Mode Input Voltage Range Includes Negative Rail
Copyright © 1999, Texas Instruments Incorporated
On products compliant to MIL-PRF-38535, all parameters are tested unless otherwise noted. On all other products, production processing does not necessarily include testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
元器件交易网 TLC226x, TLC226xA Advanced LinCMOS™ RAIL-TO-RAIL OPERATIONAL AMPLIFIERS
SLOS177A – FEBRUARY 1997 – REVISED JULY 1999
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. Advanced LinCMOS is a trademark of Texas Instruments Incorporated.
0°C to 70°C – 40°C to 125°C – 40°C to 125°C – 55°C to 125°C
The D packages are available taped and reeled. Add R suffix to device type (e.g., TLC2262CDR). The PW package is available only left-end taped and reeled. Chips are tested at 25°C. TLC2264 AVAILABLE OPTIONS PACKAGED DEVICES TA VIOmax AT 25°C 2.5 mV 950 µV µ 2.5 mV 950 µV µ 2.5 mV 950 µV 2.5 mV SMALL OUTLINE (D) TLC2264CD TLC2264AID TLC2264ID TLC2264AQD TLC2264QD — — CHIP CARRIER (FK) — — — — — TLC2264AMFK TLC2264MFK CERAMIC DIP (J) — — — — — TLC2264AMJ TLC2264MJ PLASTIC DIP (N) TLC2264CN TLC2264AIN TLC2264IN — — — — TSSOP (PW) TLC2264CPWLE TLC2264AIPWLE — — — — — CERAMIC FLATPACK (W) — — — — — TLC2264AMW TLC2264MW
D D D D
Low Input Offset Voltage 950 µV Max at TA = 25°C (TLC2262A) Macromodel Included Performance Upgrade for the TS27M2/M4 and TLC27M2/M4 Available in Q-Temp Automotive HighRel Automotive Applications Configuration Control / Print Support Qualification to Automotive Standards