富迪斯通FT09S矢量型说明书

合集下载

调速器硬件手册

调速器硬件手册
3.41 电流规格 .............................................................................................................. 13 3.5 791 2象限调速器所用的熔断器和电抗器...................................................................... 14
ETD 790直流调速器
页码:2 /86
ETD 790直流调速器 电流预测控制
6.4e 模拟输出 .............................................................................................................. 39 6.4f 422/485串行口....................................................................................................... 41 6.4g 直流测速电机反馈接线 ......................................................................................... 42 6.4h 用于指示输入和输出的LED指示器 ....................................................................... 43 6.5 RS 232、CAN总线、编码器1、编码器2的连接器....................................................

SECULIFE ST 多功能测试仪说明书

SECULIFE ST 多功能测试仪说明书

As a multifunctional test instrument, the SECU LIFE ST is ideally suited for performing and documenting measurements at medical devices. It allows for precision testing of portable medical devices, and can also be used for large devices such as X-ray equipment and MRI scanners.Standard11 Jack for protective conductor at device under test2 Jack for neutral conductor at device under test3 Jack for phase conductor at device under test4 Jack for connecting the probe5 Jack for connecting the probe6 Function selector switch: – Function Test: Function test– Auto: Automatic test sequence according to selected standard– PE: Protective conductor test– Iso/HV: Insulation test / high-voltage test– I leakage: Leakage current measurement– VΩ: Multimeter functions– Aux: Auxiliary multimeter functions– Setup: Device configuration7 scroll key for menu and parameter selection8 scroll key for menu and parameter selection9 LCD window10 Socket connector interface RS232 for (P)SI module SECUTEST PSI/SI+, storage adapter SECUSTORE, barcode or RFID scanner11 Signal lamp for mains connection error12 key for entry and for starting test sequences and finger contact13 help key (context sensitive)14 Key next to the symbol for switching test voltage to the test socket (only possible if symbol LED is blinking)15 Signal lamp for the functions test16 Functional earth (equipotential bonding)17 Operational earth18 Connector jacks for application parts19 Push-buttons (left and right) for releasing the handle from its snap-in position20 Earthing contact socket for service purposes (Feature B01), e.g. for connecting a notebook or an A4 format printer21 Standard outlet socket (test socket) for connecting the device under test22 Push-buttons (left and right) for releasing the lid23 Lid24 Compartment for probe and accessories25 Cover or (P)SI module (accessory SECUTEST PS I or SECUTEST SI+)26 Carrying handle and tilt standElectrical safety testing:•Electrical medical devices per DIN VDE 0751 / IEC 62353 and EN 60601 2nd and 3rd edition•Electrical equipment per DIN VDE 0701-0702•Routine tests, e.g. per EN 61010, EN 60950, EN 60335 etc.Measuring options:•Protective conductor resistance with 200 mA and 10 A test current•Insulation resistance•Earth leakage current•Contact current (device leakage current)•Patient leakage current, AC and DC•Patient auxiliary current•Equivalent leakage current procedure•Direct measurement•Differential current measurementLook up the reasons for the measurement option that fit in DIN EN 62353:2008-08 / EN 62353:2008 (direct measurement / differential current measurement / Leakage current)•Up to 10 application parts can be connected (4 mm) and individually assigned to groups•Internal memory for 125 testsInterfaces:•RS 232 port•SecuStore memory adapter (optional)Power supply: mains connection for 110 V / 60 Hz, 230 V / 50 HzOptions: printer-memory-interface (PSI module)Software: The SECU LIFE ST is compatible with PS3, visualFM, Fundamed, MD Data and other software packages.Hint: testing in the Auto Mode will test the device under predefined norms. You can store the values in the memory. Measurements that are done in the other modes cannot be stored in the memory!Measuring Protective Conductor resistanceDefinitionProtective conductor resistance is the sum of the following resistances:• Connector cable or device connector cable resistance• Contact resistance at plug and terminal connections• Extension cable resistance if utilizedResistance is measured:• Between each conductive part of the housing and the earthing contacts at the mains and the device plug (if a removable mains connector cable is used), or the protective conductor terminal for permanently installed devices.• as 4-pole measurement• Between the earthing contacts at the mains plug and the earthing contacts at the device plug for device connector cables• Between the earthing contacts at the mains plug and the earthing contacts at the coupling socket for extension cablesConnecting Safety Class I Devices to the Test SocketWhen the DUT is connected, resistance is measured between the protective conductor terminal at the test socket or at the PE jack and the probe connection at the DUT (contact with conductive parts of the housing).In order to measure protective conductor resistance, contact a conductive part of the housing with the probe, which isconnected to the protective conductor.During measurement, the connector cable must only be moved in as far as it is accessible during repair, modification or testing. If a change in resistance occurs during the manual test step of the continuity test, it must be assumed that the protective conductor is damaged, or that one of the connector contacts is no longer in flawless condition.Pay attention on the type of the DUT to define the limit of the measured values!Connection DUT with the SECU LIFE ST and connection with the probeIsolation MeasurementIsolation Resistance RINSDefinitionSafety Class IIsolation resistance is measured between short-circuited mains terminals and the protective conductor.Safety Classes I I and I I IIsolation resistance is measured between short-circuited mains terminals and external conductive parts which can be contacted with the probe.SequenceCurrent is displayed during this type of equivalent leakage current measurement which would flow during leakage current measurement conducted in accordance with device regulations with nominal voltage. Leakage current measurement in accordance with the respective device regulations is usually not possible, because the device would have to be set up in an electrically isolated fashion, or connected to an earth isolated power supply to this end.Equivalent Leakage Current IEL DIN VDE 0701-0702 / 2 K→Select the I-EL measurement and start.Equivalent leakage current is measured between short-circuited N and L, and the protective conductor PE. Measuring circuit resistance is equal to 2 kΩ for VDE 0701-0702 for the simulation of the mean body resistance of a human being.Equivalent Device Leakage Current IEDL for IEC 62353 (VDE 0751-1) / 1 K→Select the I-EDL measurement and startEquivalent device leakage current is measured between short-circuited N and L, and the probe. Measuring circuit resistance is equal to 1 k Ω for IEC 62353/VDE 0751 for the simulation of mean patient resistance.Equivalent Patient Leakage Current IEPL (IEC 62353 (VDE 0751-1))→Select the I-EPL measurement and startEquivalent patient leakage current is measured between short-circuited N and L and the respective application part. Jacks A through K (application parts) are connected separately for each application part. Groups of cables or sensors can be assigned to application parts in the test sequence start menu in accordance with IEC 62353 (VDE 0751-1) or EN 60601.Pay attention on the type of the DUT to define the limit of the measured values!B=Body, BF= Body Float, CF = Cardiac FloatConnection DUT with the SECU LIFE ST and connection on the DUT (in this case: infusion pump)Leakage Current MeasurementSelect the Ixx measurement and startEach time line voltage is applied to the test socket, L and N are reversed,Earth Leakage Current IPE (Feature KA01)Current which flows from the power pack over the insulation to the protective conductor, and thus to earth.Contact CurrentCurrent which flows from housing parts which are not connected to the protective conductor via an external conductive connection to earth or another part of the housing. Flow of current via the protective conductor is excluded in this case.The AC component is measured. The DC component can also be measured if individual measurement is performed (instead of a test sequence).EN 60 601/VDE 0751:The following sequence is programmed for measuring and documenting several exposed conductive parts:If the acoustic signal chain changes from long to short intervals, it means that measurement is completed and the next measuring point can be selected and scanned (key).Patient Leakage Current IPLCurrent which flows from an application part via the patient to earth. This current may be caused by an unintentional interference voltage at the patient, and may flow via the patient and an insulated, floating type F application part to earth. Useful patient current is excluded in both cases. AC and DC components are measured.Patient Auxiliary Current IPA (Feature KA01)Current which flows within the patient between the electrodes of the application part. Use for intended purpose is assumed. Furthermore, the current should not cause any physiological effects.For example, this is the case for input current from amplifiers, or current used for impedance plethysmography.AC and DC components are measured.Residual Current IRCSum of instantaneous current values which flow via the L and N conductors at the device mains connection (also known as differential current).Residual current is practically identical to fault current in the event of an error. Fault current: Current which is caused by an insulation defect, and which flows via the defective point.Device Leakage Current ILC per IEC 62353 (VDE 0751-1)Device leakage current is the sum of all leakage currents from the housing, all accessible conductive parts and all application parts to PE. Measurement must be performed for both mains polarities and the largest value is documented.Connection to the DUTMultimeter FunctionsProbe Voltage Uprobe– Max. 300 VVoltage is measured between the mains PE terminal at the test instrument and the probe. In this case the probe can also be used as a phase finder.For IEC 61 010: A selection can be made with the up scroll key as to whether testing will be conducted under normal conditions, or with interrupted protective conductor.For conducting the measurement the DUT must be put into service via key (14).Start the Uprobe measurement.Alternating / Direct Voltage UAC/DC– Max. 253 VDirect, alternating and pulsating voltages of up to 253 V can be measured between the 2 and 3 connector jacks.Furthermore, it is possible to switch between minimum, maximum and momentary measured value via key. This is particularly useful in combination with the SECULOAD test adapter for welding equipment (article number Z745).7。

WFT09(S)II 简易说明书 CN

WFT09(S)II 简易说明书 CN

1024/4096PCMS九通道2.4GHz遥控器感谢选用天地飞产品。

请在使用前详细阅读使用说明书,确保使用安全。

●售后服务●安全提示●产品配置如果您忽略此标志所指的操作说明,而做出错误的操作,有可能会造成使用者或他人死亡等严重危险伤害。

如果您忽略此标志所指的操作说明,而做出错误的操作,有可能会造成使用者或他人严重伤害或物品损坏。

如果您忽略此标志所指的操作说明,而做出错误的操作,有可能会造成使用者或他人的伤害或者物品损坏。

任何情况下都禁止尝试的操作。

任何情况下都请您务必遵守。

标志含义危险警告注意禁止务必遵守1.本使用说明书所记载的产品,在国内的无线电法令规定下,用途仅限于模型应用。

2.本产品在改装、调整、更换零件后,本公司将不负任何责任,敬请谅解。

本产品的用途、改装等注意事项1.WFLY 产品自购买之日起,属于质量问题一年内由深圳市天地飞科技开发有限公司免费保修(公司承担往返邮费)。

2.WFLY 产品自购买之日起七天内,在正常使用的情况下出现质量问题,外观无损坏,可凭保修卡及购机凭证在经销商处免费更换同型号产品;经销商收到更换产品时必须第一时间通知公司予以备案更换。

3.WFLY 产品将由深圳市天地飞科技开发有限公司提供终身售后服务;对于自购买之日起,人为损坏、改装、开盖损坏封条以及超过一年免费保修期的,用户必须支付往返邮费、材料成本费及维修成本费用。

4.为确保您的权益受到保护,并能及时有效的为您服务。

请在购买WFLY 产品时务必完整填写好保修卡及索要购机凭证;由销售商签字盖章。

用户享受本售后服务条款必须提供保修卡及购机凭证,缺一不可;销售商没有给消费者保修卡或不按要求填写的,由销售商承担全部的售后服务费用。

5.本售后服务条款仅限于中国大陆销售的WFLY 产品。

售后服务注意警告安全提示 (注意事项)在使用前请确认商品的配件是否都有备齐,接收机是否已经正常连接三线开关,舵机,遥控器与接收机是否都连接好了电源,以及确认是否都可开启并且有正确的动作后再使用。

9-2和3极联接器说明书

9-2和3极联接器说明书

A201, A251 Size 9 2 and 3 Pole Contactors, Non-reversing and ReversingFig. 1 Front Connected 3 Pole ContactorFig. 2 Rear Connected 3 Pole ContactorFig. 3 Dimension Drawings (Dim. in inches)Size 9 Contactors are designed for the control of inductive or non-inductive loads at voltages between 24 and 600, AC. The units are suitable for mount-ing on either steel or insulated panels. All parts are front removable. Contac-tors should be protected against short circuits by branch circuit protective devices selected in accordance with the National Electrical Code (NEG).Two pole contactors have the same current ratings as 3 pole devices but are not suitable controlling 3 phase motors.This industrial type control is designed to be installed, operated, and main-tained by adequately trained workmen. These instructions do not cover all details, variations, or combinations of the equipment, its storage, delivery, installation, check-out, safe operation, or maintenance. Care must be ex-ercised to comply with local, state, and national regulations, as well as safety practices, for this class of equipment.CONTACTOR RATINGS - 3 POLE CONTACTORS Continuous Current Three Phase Horsepower at:Open 2500AEnclosed 2250A230 Volts 800460 Volts 1600Three Phase Switching at:T ransformers Capacitors 208 Volts 240 Volts 480 Volts 600 Volts337 KVA 392 KVA 783 KVA 975 KVA575 KVAR 655 KVAR 1325 KVAR 1670 KVARCONTACTOR RATINGS - 2 POLE CONTACTORSSingle Phase Switching at:T ransformer Rating120 Volts 240 Volts 480 Volts 600 Volts112 KVA 225 KVA 450 KVA 562 KVAA201 And A251, Size 9 Contactors Coils.Each size 9 contactor has a single winding ,DC coil rated such that it canbe supplied from a full wave rectifier operating at 120 volts AC. As theoperating magnet armature approaches its sealed position a late-break,normally-closed auxiliary contact opens and introduces a resistor into thecoil circuit reducing the voltage across the coil to approximately 17 voltsDC. See Figures 4 and 5 for control circuits. The control relays (CR) shownin Figures 4 and 5 are not included with the contactor. The 120 volt, 60hertz control power transformer or separate supply must be capable ofsupplying 2100 VA inrush and 350 VA (350 Watts) continuously while main-taining an AC voltage of not less than 115 volts to the rectifi er, in additionto supplying control relays and other control circuit devices such as indicat-ing lights. Overcurrent protection for the control circuit (#12 AWG) shouldbe provided at the source of control voltage in accordance with the NEC.The coils have been designed to operate at high temperatures, and areinsulated to meet such service. The operator should not be alarmed to fi ndthe coils hot to the touch.Changing Coils.To remove and replace the operating coil, proceed as shown below. Item( ) references are to Fig. 6. Tightening torque values are shown in Table 1.1. Turn all power OFF.2. Remove the arc quencher (1) adjacent to the coil.3. Remove the coil (2) leads and adjacent phase barrier (3).4. Remove the two screws holding the auxiliary contact support bracket(4) to the lower horizontal brace. Let the attached leads support theauxiliary contact assembly (5).5. Remove the armature stop (6), magnet pole face (7), shim retainer(8), and stop bracket (9), by removing the five 1/2-13 cap screws andtwo spacers (10). The armature (11) can now rotate out of the way tofacilitate coil removal from the magnet core.6. Replace the coil.7. Remount the retainer, shim and pole face, ensuring that the shim islocated between the magnet core and the pole face. Tighten the capscrew holding the pole face to the core.8. Attach the armature stop bracket and shorter spacer to the left sideof the pole face. Insert the longer spacer between the pole face andend plate. Rotate the armature forward and attach the armature stop.9. Torque the five cap screws to 100 pound-feet.10. Reattach the auxiliary contact assembly to the lower brace.11. Attach the coil leads.12. With the power circuit disconnect open, energize the coil circuit.13. Check to confirm that, with the armature sealed:(a) The armature is centered on the pole face within 1/32 inch.(b) There is approximately 1/16 inch clearance between the armatureand lower pole face.(c) The electrical interlocks’ plunger can be depressed an additional1/16 inch before bottoming out.Loosen and adjust parts as necessary.14. Attach the phase barrier and arc quencher.Fig. 4 Non-reversing Control CircuitFig. 5 Reversing Control Circuit2Instructions Leafl et IL16978Effective October 2011A201, A251 Size 9 2 and 3. Pole Contactors,Non-reversing and Reversing EATON CORPORATION Contact Inspection And Replacement.To inspect contacts and replace them proceed as shown below. Item refer-ences are to Figure 6. Contact replacement is necessary when the contactovertravel, measured at point X, Figure 7, has been reduced to 3/32 inch.1. T urn all power OFF .2. Remove arc quenchers (1) and phase barriers. (3)3. Remove moving contact shunt bolts (12).4. Remove clamps (13) holding moving contact assembly to the shaftand remove assembly from shaft.5. Remove stationary contact bolts (14).6. Install new stationary contacts and bolts. Refer to Table I for boltdriving torques.7. Install new moving contact assembly on the shaft and bolt shuntends to contacts.8. See page 4 for contact adjustment.9. Replace arc quenchers and phase barriers.Operation And Maintenance.The arc quenchers must be in place when the contactor interrupts a circuit.Each arc quencher is held in place by two screws located at the top. Two pins projecting from the stationary contact support engage notches in the lower rear sides of the arc quencher and serve to position it. A notch mold-ed in the arc quencher cap engages the support plate to hold the arc box in position while the two screws are being assembled. The legs of the arc quencher grid plates are protected from the arc by ceramic barriers, which must be in place when the contactor is operated.Reversing Contactors.Reversing contactors consist of two contactors with power poles intercon-nected by buswork, normally-closed electrical interlocks, and a Type M-52 mechanical interlock.Fig. 6 Cutaway View3Instructions Leafl et IL16978Effective October 2011A201, A251 Size 9 2 and 3. PoleContactors,Non-reversing and ReversingEATON CORPORATION A201 And A251 Size 9 Contactors.Mechanical InterlockThe Type M-52 mechanical interlock is used when a pair of contactors must be mechanically protected against the closing of one when the other is already closed. The two contactors may be exactly alike or may be mixed as to size or number of poles. They must be mounted one below the other, as shown in Figure 3.The Type M-52 mechanical interlock consists of a lower operating lever, a tie rod, and an operating pin secured to the top of the armature of the lower contactor and to the bottom of the armature of the upper contactor. With the upper contactor open and the lower contactor closed, adjust the tie rod so that the lower operating lever clears the operating pin by 1/4 inch. Tighten the tie rod lock nuts. Then make sure, by alternate manual closing of fi rst one contactor, then the other, that interlocking action is correct.Auxiliary Contacts - L64Two double-circuit L64 auxiliary contacts (electrical interlocks) are supplied with each contactor in addition to the normally-closed, late-break contact that introduces resistance into the coil circuit. One normally-open circuit can be used in the coil holding circuit of the control relay that supplies voltage to the contactor coil and one normally-closed circuit can be used for electrical interlocking. The second double-circuit auxiliary is available for circuit monitoring.Contact Adjustment.Make sure that all contact pairs touch simultaneously within 1/32 inch. Suffi cient adjustment can generally be obtained by a selective tightening of the two bolts securing the shaft clamp (13) to the moving contact bracket (Figure 7), tightening one more than the other to produce a slight rota-tion of the assembly on the shaft (17). When adjusted, the contact air gap should be 3/4 inch with the armature in the fully open position. A gap of 3/16 to 7/32 inch, measured at Point X, Figure 7, is typical with newly in-stalled contacts when the armature is in the fully closed position.Contact Spring Forces.Measure the contact force at the top of the moving contact inlay and in line perpendicular to the moving contact (15). The contactor employs multiple contacts in parallel for each pole. The forces given below are for each con-tact. See Figures 6 and 7.To measure the initial force; exert a measured pull with the contactor open until the shank of the moving contact just leaves its stop.To measure the fi nal force, keep the armature (11) fully seated against the magnet pole face (7) and exert a measured pull until the contacts just startto separate. Contact forces with new contacts should be as follows:L64 CONTACT RATINGS(1 normally-open, 1 normally-closed) - A600Part Number Volts Make Break843D943G0424-120 AC120-600 AC24-600 DC60 A7200 VA200 VA6 A720 VA200 VATABLE I RECOMMENDED DRIVING TORQUELocation (Qty.)Driving T orque(LB/IN)Fig. 6Item NumberWire LugsLug Mtg. ScrewsArc Quencher Scr.Shaft ClampCap ScrewsSta. Contact boltShunt boltControl CircuitElectrical Connections(8/pole)(8/pole)(2/pole)(2/pole)(5)(2/pole)(8/pole)4005504080120025012515(19)(20)(21)(22)------------TABLE II RENEWAL PARTSITEM PART NUMBERCoil, 100VDC for use with 120VACRectifi erRectifi er, 120 VACSeries ResistorSet of Contacts for one pole,completeWire Lug (4/0 - 500MCM)5264C34G012018A40G01443A327H315264C42G017865A40H05Fig. 7 Contact Overtravel and Force MeasurementINITIAL FINALContact Spring Force10-18 LBS.24-30 LBS.Eaton CorporationElectrical Sector1111 Superior Ave.Cleveland, OH 44114United States877-ETN-CARE (877-386-2273)© 2011 Eaton CorporationAll Rights ReservedPublication No. IL16978 / 001October 2011Eaton is a registered trademark of EatonCorporation.All other trademarks are property of theirrespective owners.Instructions Leafl et IL16978Effective October 2011A201, A251 Size 9 2 and 3. Pole Contactors,Non-reversing and Reversing。

富斯9通说明书

富斯9通说明书

MENU: 主菜单功能按钮ENT : 退出按钮UP :菜单向上选择DOWN: 菜单向下选择+ :增加参数的值—:减少参数的值注意区分:长按和短按1,持续按键2秒以上。

2,持续按键不超过1秒(微调显示)(编码方式)(比赛时间指示)(模式选择)(用户名)(型号选择)*电池电压指示:检测当前电源电压的值(如果电池电压低于8.5V后,BUZZER每隔5S发一次提示音*编码方式:发射机的发射数据的编码格式(包含PPM和PCM)*模式选择:用户参数编号显示(最多8组可以选择)*用户名字:当前用户的名字(用户名可以自定义,最长8个字符)*微调指示:副翼,升降,方向,油门通道的微调指示*型号选择:机种型号选择(飞机,直升机,滑翔机)*比赛时间:比赛倒计时(最长时间99分59秒)长按MENU键进入主菜单设置(大约2秒)(系统设置)(基本功能设置)*系统设置(SYSTEN SETTING):对系统的初始化设定*基本功能设置(FU NC SETTING):机种功能参数设定*使用UP DOWN选择SYSTEN SETTING和(FU NC SETTING。

然后,短按(1秒左右)MENU确定进入相应菜单或者按EXIT键退出设置菜单*菜单每动作一次BUZZER发一次声音*如果是菜单中参数调到最大值后,继续按按钮,BUZZER将不会发出音系统设定功能*MODEL SELE :模式选择*MODEL NAME :用户名称编辑*TYPE SELE :机种型号的选择*MODEUAT :调制模式选择*STICK SET :控制杆的模式选择(左右手油门互换)*COPY :复制成初始化3-1模式选择(MODEL SELE)*功能说明:为不同机种的操作调出不同用户的设定*系统总共包含8种模式,也就是说能够存储8种不同形式的设置为不同的用户,每次使用只要选择它就能够调出相应的设置。

*使用UP DOWN按钮选择,如果选择第一项其他颜色会翻转*然后短按MENU选择保存并返回上一项菜单,按EXIT键不保存并返回上一项菜单)3-2用户名称编辑(MODEL NAME*功能说明:编辑用户的名称*使用UP ,DOWN按钮选择,如果选择某一项其颜色会翻转,使用(—),(+)选择不同的字符,包含有(数字,字母等,空格)。

富迪斯通FT09S矢量型变频器说明书

富迪斯通FT09S矢量型变频器说明书

前言FT09S系列变频器是常州市富兆电子有限公司推出的代表未来发展方向的新一代高性能矢量变频器。

FT09S系列变频器是我公司自主研发生产的高品质、多功能、低频起动转矩大、低噪音的矢量控制通用变频器。

通过对电机磁通电流和转矩电流的解耦控制。

实现转矩快速响应和准确控制,能以很高的控制精度进行宽范围的调速运行,主要完成对电机的高性能控制和全方位保护。

FT09S系列变频器具有参数自动调谐、零伺服控制、速度控制和转矩控制在线切换、完善的用户密码保护、快捷的菜单设计、转速追踪、内置PLC、内置PID控制器、给定及反馈信号断线监测切换、掉载保护、故障信号追踪、故障自动重起、内置制动单元、25种故障保护、故障监控、丰富的I/O端子、各种速度设定方式、自动电压调整、摆频控制、多段速控制,能满足各类负荷对传动控制的要求。

键盘由LED显示运行数据和故障代码,LCD显示中文状态信息和操作说明,并能对参数进行拷贝和下传复写功能;功能强大的后台调试监控软件可通过内置的标准RS485接口网监控运行;MODBUS总线协议。

紧凑的结构、别具一格;按照国际标准进行设计和测试,保证产品的可靠性;丰富的选配件,供您进行多种配置选择。

本手册提供给使用者选型、安装、参数设置、现场调试、故障诊断及日常保养与维护的相关注意事项及指导。

在使用FT09系列通用矢量变频器之前,请您仔细阅读本手册,以保证正确使用。

不正确的使用可能会造成变频器运行不正常、发生故障和降低使用寿命,乃至发生人身伤害事故。

因此使用前应反复阅读说明书,严格按说明使用。

本手册为随机发送的附件,务必请你使用后妥善保管。

设备配套客户请将此手册随设备发给最终用户。

目录第一章: 安全及注意事项 (1)1.1 安全事项 (2)1.2 注意事项 (3)第二章: 产品信息 (5)2.1 命名规则 (5)2.2 铭牌 (5)2.3 FT09S变频器系列机型 (6)2.4 技术规范 (8)2.5 外形及安装尺寸 (10)2.6 选配件 (11)2.7 变频器的日常保养和维护 (11)2.8 选型指导 (12)第三章: 机械与电气安装 (13)3.1 机械安装 (13)3.2 电气安装 (15)3.3 接线方式 (20)3.4 主回路端子及接线 (21)3.5 控制端子及接线 (22)3.6 EMC问题处理 (24)第四章: 操作与显示 (26)4.1 操作与显示界面介绍 (26)4.2 操作流程 (28)4.3 状态参数查看方法 (29)4.4 快速功能 (31)第五章: 功能参数简表 (32)第六章: 详细功能说明 (43)第七章: 故障诊断及对策 (74)第八章: 保养维护 (77)8.1 日常维护 (77)8.2 定期维护 (77)8.3 变频器易损件更换 (77)8.4 变频器的保修 (78)第九章:通讯协议 (79)9.1 协议内容 (79)9.2 应用方式 (79)9.3 总线结构 (79)9.4 协议说明 (79)9.5 通讯帧结构 (79)9.6 命令码及通讯数据描述 (82)第一章 安全及注意事项本说明书包括有使用时的操作说明和注意事项。

9RS说明书

9RS说明书

9RS-900型饲草揉丝机说明书前言尊敬的用户朋友:欢迎您使用本公司的产品,在安装使用本机前,请仔细阅读本说明书,以免因使用不当,造成机器故障或人身事故,给您造成不必要的经济损失和人身伤害。

本说明书介绍的机型为滚刀式饲草揉丝机,该机具有性能先进、效率高、工作可靠、操作安全等优点。

自带行走轮,固定、流动作业均可使用。

该饲草揉碎机结构简单,容易维修、保养,适用于切碎各种干湿草类、玉米、水稻、花生、豆类、薯类秸杆等各种饲草,是广大农村和中小型饲料加工厂必备的机械设备,也可供农牧场及造纸厂使用。

该饲草揉碎机的配套动力为18.5kw四极、0.5kw二级吹风机电机、1.5kw二级吹风机电机和1.5kw四极减速机电机。

配套动力必须符合额定的转速,严禁超速运转,否则,出现的后果公司概不负责。

该饲草揉丝机,无论固定作业或流动作业,都必须注意配套后应在动力之间加防护装置以免发生危险。

该饲草揉丝机执行标准GB/T20788-2006,对本说明书的错误地方,请用户批评指正。

地址:河南新乡工业园区目录一、安全注意事项及警示二、技术规格及配套要求三、安装、调试方法四、操作说明五、维修保养六、常见故障和排除方法七、适用范围八、结构和工作原理九、易损件及附件清单十、征集用户意见书9RS-900型饲草揉碎机故障和修理记录表一、安全注意事项及警示1、开机工作前按产品使用说明书的规定进行调整和保养。

检查各紧固件是否锁紧,刀轮转向是否与规定的方向相同,上机壳是否锁住。

应严格按说明书的规定进行操作。

2、该饲草揉丝机的工作场地应宽敞、通风,并备有可靠的防火设备,3、应根据所购机型的铭牌选配套动力。

不准随意提高主轴转速,严禁超速运转,不准随意拆掉个各部分的防护装置。

4、该饲草揉丝机所配电机、电器应有接地装置。

5、作业时如发现异常声响,应立即停机检查,禁止在机器运转时,排除故障。

6、加工过程中,喂料口堵塞时,不准用手或木棍、铁棒帮助喂入。

更换刀片的紧固件时,不得用普通紧固件代替。

Festo Didactic LabVolt Series 帝士达克 电动仪器 英制单位 产品说明书

Festo Didactic LabVolt Series 帝士达克 电动仪器 英制单位 产品说明书

LabVolt Series Datasheet Electrodynamometer, Imperial Units586856 (8911-00)* The product images shown in this document are for illustration purposes; actual products may vary. Please refer to the Specifications section ofeach product/item for all details. Festo Didactic reserves the right to change product images and specifications at any time without notice.Festo Didactic en 120 V - 60 Hz 12/2023Electrodynamometer, Imperial Units, LabVolt SeriesTable of ContentsGeneral Description_________________________________________________________________________________3 Specifications______________________________________________________________________________________3Electrodynamometer, Imperial Units, LabVolt SeriesGeneral DescriptionThe Electrodynamometer is made of a squirrel-cage rotor fitted in a dc-excited stator. Mechanical loading is achieved by increasing the stator field current, which generates eddy currents in the driven rotor. The stator is trunnion-mounted on ball bearings and rotates against a helicoidal spring to oppose braking torque.The front-end bell is provided with a circular scale that indicates the torque developed. The circular scale is graduated in Imperial units (lbf⋅in). A damper lever is located underneath the dynamometer to prevent oscillation if the power supply is applied while the dynamometer is turning. To measure the torque, this lever can be pushed to adjust and read the torque. The Electrodynamometer is electrically powered from standard fixed ac line supply.The Electrodynamometer can be coupled to a 0.2 kW drive motor through the use of the Timing Belt, Model 8942. The faceplate can be lowered to provide access to the inside for coupling the Electrodynamometer to the drive motor. When closed, the faceplate is secured by two quick-lock fasteners.A variant of the model expressing values in the International System of Units (SI) is also available (see Model 8911-1).SpecificationsParameter ValueRatingTorque Range (8911)-3 to +27 lbf·inSpeed250 to 3000 r/minAccuracy2%Input Voltage120 V – ACInput Current 2 APhysical CharacteristicsDimensions (H x W x D)308 x 291 x 490 mm (12.1 x 11.5 x 19.3 in)Net Weight17.4 kg (38.3 lb)Electrodynamometer, Imperial Units, LabVolt Series Reflecting the commitment of Festo Didactic to high quality standards in product, design, development, production, installation, and service, our manufacturing and distribution facility has received the ISO 9001 certification.Festo Didactic reserves the right to make product improvements at any time and without notice and is not responsible for typographical errors. Festo Didactic recognizes all product names used herein as trademarks or registered trademarks of their respective holders. © Festo Didactic Inc. 2023. All rights reserved.Festo Didactic SERechbergstrasse 373770 DenkendorfGermanyP. +49(0)711/3467-0F. +49(0)711/347-54-88500Festo Didactic Inc.607 Industrial Way WestEatontown, NJ 07724United StatesP. +1-732-938-2000F. +1-732-774-8573Festo Didactic Ltée/Ltd675 rue du CarboneQuébec QC G2N 2K7CanadaP. +1-418-849-1000F. +1-418-849-1666。

新9通WFT09(S)II新说明书(中文)2011-06-09

新9通WFT09(S)II新说明书(中文)2011-06-09

使用时,请注意天线摆放为90度 ,才能更好发挥双天线双接收的性能。
接收机的连接
由于各种机型所附配件不同,功能各异,图示仅限参考。
符号 通道 固定翼用 直升机用
1
Ch1 副翼
副翼
2
CH2 升降舵
升降舵
1
3
CH3 油门
油门
2 3
4
4
CH4 方向舵
方向舵
5
6
5
CH5 起落架
陀螺仪
7 8
9/T
6
CH6 襟翼
系统设置 63 1 机型参数选择 64 2 机型名称 65 3 机型设置 66 4 低速微调 67 5 调制类型
第8页
目录
68 6 十字盘类型 69 7 控制杆设置 70 8 控制杆校准 71 9 恢复出厂设置 72 10发送数据 73 11接收数据 74 12提示音设置 75 13对比度设置 76 14ENGINEER MODE 76 15版本信息
第2页
产品特点
WFT09SII/WFT09II/WFR09S
超 级版WFT09SII/普通版WFT09II发 射 机
■ 具备功 能 齐备的9通 道 遥控器 。 ■ 采用了 看 读方便 , 字迹清 晰 的特制 的1 3 2*64FSTN液晶 显 示器, 以 及便于 了解, 操 控方便 的 输入 键与电脑记忆系统。 ■ 采用了 优 异的白 色L ED背光 源,长 时间使 用 视觉不 易 疲劳。 ■ 采用了中文显示。 ■ 改善遥杆头的形状,采用了更适合操纵的设计。 ■ 微调全面采用了高级数字微调,微调可变调提示音,让调试更为轻松。 ■ 采用了可调整摇杆长度与弹性的摇杆,可让每个人都找到适合自己的操纵感。 ■ 可记录W FT09 I I 1 5组;WF T 09SII 85组 机型 的 全部资 料 。 ■ 可切换飞行模式。直升机,飞机,滑翔机皆可共用。 ■ 15/ 8 5组 机型 资 料也可 以 分别记 录各自 的 飞行模 式 。 ■ 采用了 高 速度, 高 分辨率 , 优化的2 .4GHz PC M S 4 096制 式 。 ■ 采用了树状分层菜单,人性化设计,操控更为便捷。 ■ 有教练功能的基本配备。 ■ 有DS C与 充电插 孔 的基本 配 备。 ■ 配备有各式的计时器功能。 ■ 配备有数据拷贝功能。 ■ 配备有1 0点曲 线 编辑 功 能。 ■ 装载了 可 编程普 通 (7组混控 ) 可编程 曲 线(4组混 控 )。 ■ 便捷的控制杆校准 让您的习惯成自然 ● 更 安 全可靠 内 置RF模 块无需 插 针连接 。 ● 更 方 便省电 菜 单增加RF模块 开 关功能 。 ● 更便捷菜单内一键式对码。 ● 更美观 全新面板设计。 ● 更 专 注 专业2.4G领域 研 发。

Schurter PG09前面开关的数据手册说明书

Schurter PG09前面开关的数据手册说明书

Frontpanel Switch / Momentary or Latching, Medium Stroke, 10 mmSee below:Approvals and CompliancesDescription- Available in version square or round in different colours- non-illuminated or illuminated- 1- or 2-pole Frontpanel and PCB Mounting- Solder, THT or solder lugsUnique Selling Proposition- Absolute reliability and simple assembly- Compact design with very small mounting depth- Good illuminationWeblinkshtml data sheet, General Product Information, CAD-Drawings, ProductNews, Detailed request for productT echnical DataElectrical DataSwitching Voltage min. 100 mVAC/DC , max. 48 VAC /48 VDCSwitching Current max. 200 mALifetime> 100'000 actuations at Rated Swit-ching Capacity 1.2 WContact Resistance< 20 mΩ< 25 mΩ after lifetimeInsulation Resistance> 10'000 MΩDuration of Bounce typ. 0.5 msMechanical DataActuating Force 1.2 ± 0.6 NActuating Travel 1.3 ± 0.5 mmEnd Actuating Travel 2.9 ± 0.5 mmEnd Stop Strength> 50 NLifetime> 100'000 actuationsClimatical DataOperating Temperature illuminated -25 °C to 60 °Cnon-illuminated -25 °C to 85 °CStorage Temperature illuminated -25 °C to 60 °Cnon-illuminated -25 °C to 85 °CIP-Protection IP40Other DataSolderability235 °C / 2 sec (IEC 60068-2-20 Test TaMethod 1)Resistance to Soldering Heat260 °C / 5 sec (IEC 60068-2-20 Test TbMethod 1A)MaterialSocket Thermoplastic (PES)Button Thermoplastic (PC)Contact CuZn37 5 µm AgContact spring CuBe37 5 µm AgTerminals CuZn37 4 µm SN Pb 40 Approvals and CompliancesDetailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about ApprovalsSCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agree-ments by SCHURTER.Application standardsApplication standards where the product can be usedOrganization Design StandardDescriptionDesigned for applications acc.IEC/UL 60950IEC 60950-1 includes the basic requirements for the safety of informationtechnology equipment.1CompliancesThe product complies with following Guide LinesIdentification Details InitiatorDescriptionRoHS SCHURTER AG EU Directive RoHS 2011/65/EUChina RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March2007. It is similar to the EU directive RoHS.REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as"REACH") entered into force.Dimension [mm]Small buttonSmall button with solder lugsSmall button Small button with solder lugs2DimensionDrilling diagram / Wiring diagramDrilling diagram / Wiring diagram+0.2Front panel drilling+0.2Front panel drilling1234LED-terminalsN.O. Solder lug version 12 34LED-terminalsN.O.Solder lug versionAssembly InstructionsSecuring clip, round bezel button, square betel buttonNecessary for front panel mountingDiagramsNO 1 pole1NO 2 pole13All Variants3Packaging unit 100 pcsThe specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed 0 8 . 0 2 . 2 0 1 94。

AT Controls FD9-F3 300# 直接挂载分体流线球阀说明书

AT Controls FD9-F3 300# 直接挂载分体流线球阀说明书

FD9F3-3R-20230118Copyright 2013 A-T Controls, Inc.ElectricPneumaticCincinnati, Ohio SERIES FD9 300# Direct Mount Split Body Flanged Ball Valve FiresafeSee automated data sheets for pre-sized assembliesEasy to Automate!Triac FD9 Series Flanged Ball Valves feature a directmount automation pad. The high quality investment castings feature a fully machined bore. The superior live-loaded packing system is accomplished with Belleville washers, “V” ring packing and a unique primary pyramidal stem seal. This advanced sealing system provides protection against stem leaks experienced by ordinary ball valves.available for seat materials. The 50/50 STFE seat option is excellent for services that call for higher temperatures and more difficult applications, including steam. Call us for details.C E R T I F I E DFAX (513) 247-5462********************Graphite Packing 1Additional Special DesignationFD9C-F3-0300-XXX-_-_ _See part number matrix for itemized optionsHOW TO ORDER MANUAL VALVESSAMPLE PART #Valve SeriesFiresafe End ConnectionCarbon SteelSeat MaterialValve SizeSpecial Designation* 2-1/2” THRU 4” QTY = 8 PCS * 6” QTY = 12 PCSHigh Performance, Full Port300# Split Body Flanged Ball ValveSeries FD9-F3 (ASME Class 300)NOTE: A-T CONTROLS RECOMMENDS A GEAR FOR 6” VALVES AND LARGER2FD9F3-3R-20230118 | Copyright 2013 A-T Controls, Inc. | | (513) 247-5465with sizing actuators.3FD9F3-3R-20230118 | Copyright 2013 A-T Controls, Inc. | | (513) 247-5465DIMENSIONS SHOWN ARE FOR ASSEMBLIES SIZED FOR 80 PSI SUPPLY300# Flanged Direct Mount Firesafe4SAMPLE PART #FD9C-3X-150/3RED-See automated part number matrix on back cover for complete partnumber and options.Carbon Steel Valve SeriesFiresafe Seat MaterialValve SizeEnd ConnectionTRIAC Actuator SeriesActuator Size Double ActingSUFFIX 1: SUFFIX 2: ASME Class 300 FlangedFiresafe Tested to API-607Direct MountFD9F3-3R-20230118 | Copyright 2013 A-T Controls, Inc. | | (513) 247-5465DIMENSIONS (IN)DIMENSIONS SHOWN ARE FOR ASSEMBLIES SIZED FOR 80 PSI SUPPLY300# Flanged Direct Mount Firesafe5Actuators are sized based on full differential pressure with cleanwater. Consult the Application Sizing Guide for assistance with sizingactuators.SAMPLE PART #FD9C-3X-150/3RFS-XXSee automated partnumber matrix on backcover for complete partnumber and options.Carbon SteelValve SeriesSeat MaterialValve SizeEnd ConnectionTRIAC Actuator SeriesActuator SizeSpring ReturnSUFFIX 1: SolenoidsSUFFIX 2: Limit SwitchFiresafeASME Class 300 FlangedFiresafe Tested to API-607Direct MountFD9F3-3R-20230118 | Copyright 2013 A-T Controls, Inc. | | (513) 247-5465DIMENSIONS (IN)API 607 - 6th EditionC E R T I F I E D6SAMPLE PART #FD9C-3X-150/WEA1-XXSee automated partnumber matrix on backcover for complete partnumber and options.Carbon SteelValve SeriesFiresafeSeat MaterialValve SizeEnd ConnectionTRIAC Actuator SeriesActuator SizeOn-OffSUFFIX 1: VoltageSUFFIX 2: OptionsOther options available - call for detailsActuators are sized based on full differential pressurewith clean water. Consult the Application Sizing Guidefor assistance with sizing actuators.ASME Class 300 FlangedFiresafe Tested to API-607Direct MountFD9F3-3R-20230118 | Copyright 2013 A-T Controls, Inc. | | (513) 247-5465HOW TO ORDER:Manual ValvesOPTIONS:Chemraz® is a registered trademark of Greene, Tweed & Co.Markez® is a registered trademark of Marco Rubber & Plastic Products Inc.Perlast® is a registered trademark of Precision Polymer Engineering Limited Viton® is a registered trademark of E. I. DuPont de Nemours..TFM™ is a trademark of Dyneon™, a 3M Company.7FD9F3-3R-20230118 | Copyright 2013 A-T Controls, Inc. | | (513) 247-5465HOW TO ORDER:Automated Valves w/ OptionsViton® is a registered trademark of E. I. DuPont de Nemours..TFM™ is a trademark of Dyneon™, a 3M Company.(10) Special DesignationSAMPLE PART #(2) Valve Series(3) Body/Ball/StemMaterial(6) Valve Size(5) Seat, Lining & TrimMaterial(4) End Connection(7A) TRIAC Actuator Series(7A) Actuator Size(7B) Double Acting(8) Accessory(9) AccessoryAUTOMATED VAL VEFD9C-3X-150/3RED-XX-_(1) PrefixFD9F3-3R-20230118Copyright 2013 A-T Controls, Inc.9955 International Blvd.Cincinnati, Ohio 45246PHONE (513) 247-5465FAX (513) 247-5462********************8**2500 & 3500 60 psig spring。

Festo MSB6-1 2 C3J3F3M1-WP 12巴勾勒式组合说明书

Festo MSB6-1 2 C3J3F3M1-WP 12巴勾勒式组合说明书
07/01/2013 – Subject to change – Festo AG & Co. KG
Value 6 MS Rotary knob with lock with accessories, lockable Vertical +/- 5° 5 µm manual rotary Branching module Pressure sensor On/off valve Filter regulator with pressure gauge Standard oil-mist lubricator Output pressure constant with initial pressure compensation with secondary exhaust with return flow Plastic guard with pressure gauge 1.5 ... 18 bar 1 ... 12 bar 3,200 l/min Compressed air in accordance with ISO8573-1:2010 [7:4:4] Inert gases Lubricated operation possible (subsequently required for further operation) 2 -10 ... 60 °C Compressed air in accordance with ISO8573-1:2010 [6:4:-] -10 ... 60 °C -10 ... 60 °C 2,550 g with accessories G1/2 G1/2 G1/2 Aluminum die cast PC
Service unit combination MSB6-1/2:C3J3F3M1-WP

Festool 475 423_005RS 电动镂空工具操作手册说明书

Festool 475 423_005RS 电动镂空工具操作手册说明书

1475 423_005RS 300 EQFestool GmbH Wertstraße 20D-73240 Wendlingen Tel.: 07024/804-0Fax: 07024/原操作手册233 用途本机用于对木料、塑料、石材、复合材料、涂料/油漆、原子灰和其它类似材料的打磨处理。

含有石棉成分的金属和材料不适宜选用本机进行加工。

出于电气安全的考虑,本机不能在潮湿的环境中储放和工作,仅适用于干磨。

2 电动工具通用安全警告保存所有警告和说明书以备查阅。

在所有下列的警告中术语“电动工具”指市电驱动(有线)电动工具或电池驱动(无线)电动工具。

a) 工作场地的安全1) 1) 保持工作场地清洁和明亮。

保持工作场地清洁和明亮。

混乱和黑暗的场地会引发事故。

2) 2) 不要在易爆环境,如有易燃液体、气体或粉尘的不要在易爆环境,如有易燃液体、气体或粉尘的环境下操作电动工具。

环境下操作电动工具。

电动工具产生的火花会点燃粉尘或气体。

3) 3) 让儿童和旁观者离开后操作电动工具。

让儿童和旁观者离开后操作电动工具。

注意力不集中会使你失去对工具的控制。

b) 电气安全1) 1) 电动工具插头必须与插座相配。

绝不能以任何方电动工具插头必须与插座相配。

绝不能以任何方式改装插头。

式改装插头。

需接地的电动工具不能使用任何转换插头。

未经改装的插头和相配的插座将减少电击危险。

2) 2) 避免人体接触接地表面,如管道、散热片和冰避免人体接触接地表面,如管道、散热片和冰箱。

箱。

如果你身体接地会增加电击危险。

3) 3) 不得将电动工具暴露在雨中或潮湿环境中。

不得将电动工具暴露在雨中或潮湿环境中。

水进入电动工具将增加电击危险。

4) 4) 不得滥用电线。

绝不能用电线搬运、拉动电动工不得滥用电线。

绝不能用电线搬运、拉动电动工具或拔出其插头。

使电线远离热源、油、锐边或运动部件。

运动部件。

受损或缠绕的软线会增加电击危险。

5) 5) 当在户外使用电动工具时,使用适合户外使用当在户外使用电动工具时,使用适合户外使用的外接软线。

FESTO Swivel Linear Unit DSL-B 2 d 产品说明书

FESTO Swivel Linear Unit DSL-B 2 d 产品说明书

Swivel/linear units DSL-B2d Internet: /catalogue/...Subject to change – 2021/06Swivel/linear units DSL-BKey featuresAt a glance• High repetition accuracy thanks to cushioning components with fixed stop• Swivel angle can be infinitely and accurately set• The mechanical gearing between the stop element and the swivel module prevents movement of the stop system under load • Compact sensing of the swivel motion via proximity switches SME/SMT-10• With plain-bearing guide• With recirculating ball bearing guide • Swivel motion of up to 270°• Linear motion of up to 200 mm stroke• The two movements can be controlled individually or simultaneously• High rotational energy during swivelling due to self-adjusting shock absorbers which can be directly mounted• Supply ports at one end for quick, clearly laid-out tubing connections• High precision thanks torecirculating ball bearing guide – Backlash-free swivel motion – Torque load also possible during the linear motionThe technology in detail[1] Cushioning[2] Position sensing[3] Sensor bracket[4] Stop lever• Choice of two types of cushioning, each with metal fixed stop:– Elastic cushioning components – Hydraulic shock absorber • Compact sensing of the swivel position with proximity switches SME/SMT-10• The proximity switches are mounted directly on the stop system. The sensor retainer can be ordered as an accessory • The magnet in the stop lever enables the swivel angle to be sensed[5] Piston rod[6] Slot for proximity switch [7] Precision end-positionadjustment [8] Angle scaleMounting interface, for example for a gripper• Compact sensing of the linear position with proximity switches SME/SMT-8• After the lock nut is loosened, the end positions can be precisely adjusted using an Allen key • The required swivel angle can be easily preset using the scaleMounting options Direct mountingFlange mountingFlange mountingVia slot nutsWith size 16:The mounting thread on the bearing cap complies with DIN ISO 6432.With size 20 ... 40:Mounting hole pattern toDIN ISO 6431, VDMA 24 562 and NF E 49 003.1.Swivel/linear units DSL-BType codes32021/06 – Subject to change d Internet: /catalogue/...Swivel/linear units DSL-BPeripherals overview4d Internet: /catalogue/...Subject to change – 2021/06Swivel/linear units DSL-B Peripherals overview5 2021/06 – Subject to change d Internet: /catalogue/...Swivel/linear units DSL-B Data sheetFunction-N-Size16 … 40 mm -T-Stroke length10 … 200 mm -O- Force1.25 … 20 Nm -É-1) In new condition2) Per side3) At max. swivel angle4) Important: Where there is an external, alternating force, the swivel angle play of the respective variant (plain-bearing guide GF or recirculating ball bearing guide KF) must be added to the swivel angle.6d Internet: /catalogue/...Subject to change – 2021/06Swivel/linear units DSL-BData sheet1) Note operating range of proximity switches2) Corrosion resistance class CRC 1 to Festo standard FN 940070Low corrosion stress. Dry indoor application or transport and storage protection. Also applies to parts behind covers, in the non-visible interior area, and parts which are covered in the application (e.g. drive trunnions).1) Theoretical values at 6 bar.H--NoteThe vane is not suitable forend-position fixing, i.e. the stop lever and stops must not be removed.With plain-bearing guide:With eccentric attachment of thepayload and horizontal installation,increased friction forces arise inter-nally, reducing the effective force ofthe linear motion.72021/06 – Subject to change d Internet: /catalogue/...8d Internet: /catalogue/...Subject to change – 2021/06Swivel/linear units DSL-BData sheetMaterialsSectional view2134592021/06 – Subject to changed Internet: /catalogue/...Swivel/linear units DSL-BData sheetLateral force Fq as a function of stroke length l• Piston rod with bearings at both ends• For high torques and lateral forcesl [mm]F q [N ]1020406080100200124610204060100200400@16@ 20@ 25@ 32@ 40Max. permissible payload as a function of piston speed vv [mm/s]m [k g ]100200300400500024********@ 16@ 20@ 25@ 32@ 4010d Internet: /catalogue/...Subject to change – 2021/06Swivel/linear units DSL-BData sheetMax. permissible mass moment of inertia J as a function of swivel time t DSL-16-...-PDSL-16-...-CCt [s]J [k g m ]0.511.522.5310.0e-610.0e-50.0010.01t [s]J [k g m ]0.20.40.60.811.210.0e-50.0010.01DSL-20-...-PDSL-20-...-CCt [s]J [k g m ]0.511.522.5310.0e-610.0e-50.0010.01t [s]J [k g m ]0.20.40.60.811.20.0010.010.1DSL-25-...-PDSL-25-...-CCt [s]J [k g m ]0.511.522.5310.0e-50.0010.010.1t [s]J [k g m ]0.20.40.60.811.20.0010.010.190°180°270°Max. permissible mass moment of inertia J as a function of swivel time t DSL-32-...-PDSL-32-...-CCt [s]J [k g m ]0.511.522.5310.0e-50.0010.010.1t [s]J [k g m ]0.20.40.60.811.20.0010.010.1DSL-40-...-PDSL-40-...-CCt [s]J [k g m ]0.511.522.5310.0e-50.0010.010.1t [s]J [k g m ]0.20.40.60.811.21.41.61.80.0010.010.1190°180°270°H- -NoteIn the graphs for the types DSL-...-CC, the swivel time is shown up to the point when the stop lever meets the shock absorber. The cushioning time of the shock absorber must be added in order to obtain the total swivel time.H- -NoteEngineering software for calculating inertia a Dimensions for variant with plain-bearing guide. Dimensions vary for variant with recirculating ball bearing guide, see below.1)** Dimensions for X-strokes (a ordering data starting on page 14)*** Profile rod does not protrude beyond the drive unit*)X-strokes*)X-strokes*)X-strokes*)X-strokesFlange mounting FBNMaterial:Galvanised steelFree of copper and PTFE1) Corrosion resistance class CRC 1 to Festo standard FN 940070Low corrosion stress. Dry indoor application or transport and storage protection. Also applies to parts behind covers, in the non-visible interior area, and parts which are covered in the application (e.g. drive trunnions).Flange mounting FNCMaterial:Galvanised steelFree of copper and PTFE1) Corrosion resistance class CRC 1 to Festo standard FN 940070Low corrosion stress. Dry indoor application or transport and storage protection. Also applies to parts behind covers, in the non-visible interior area, and parts which are covered in the application (e.g. drive trunnions).Slot nut NSTMaterial:Non-alloyed tempered steelFree of copper and PTFE1) Corrosion resistance class CRC 2 to Festo standard FN 940070Moderate corrosion stress. Indoor applications in which condensation can occur. External visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment.Push-on flange FWSRThe permissible tightening torquemust not be exceeded when attachingadditional components to the spigotshaft.Material:Anodised wrought aluminium alloyFree of copper and PTFE1) Corrosion resistance class CRC 2 to Festo standard FN 940070Moderate corrosion stress. Indoor applications in which condensation can occur. External visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment.Cover cap AKMMaterial:PolyamideCannot be used in combination with inductive proximity switch SIEN.Swivel/linear units DSL-B Accessories1) Packaging unit21 2021/06 – Subject to change d Internet: /catalogue/...Swivel/linear units DSL-BAccessories22d Internet: /catalogue/...Subject to change – 2021/06Swivel/linear units DSL-B AccessoriesAdapter kit HAPB, HAVB Material:Wrought aluminium alloyFree of copper and PTFERoHS-compliantH--NoteThe kit includes the individualmounting interface as well as thenecessary mounting material.1) Corrosion resistance class CRC 2 to Festo standard FN 940070Moderate corrosion stress. Indoor applications in which condensation can occur. External visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment.2) For DGPL only23 2021/06 – Subject to change d Internet: /catalogue/...Festo - Your Partner in AutomationConnect with us/socialmedia 1Festo Inc.2Festo Pneumatic 3Festo Corporation 4Regional Service Center 5300 Explorer DriveMississauga, ON L4W 5G4CanadaAv. Ceylán 3,Col. Tequesquináhuac 54020 Tlalnepantla, Estado de México1377 Motor Parkway Suite 310Islandia, NY 117497777 Columbia Road Mason, OH 45040Festo Customer Interaction CenterTel:187****3786Fax:187****3786Email:*****************************Multinational Contact Center 01 800 337 8669***********************Festo Customer Interaction Center180****3786180****3786*****************************S u b j e c t t o c h a n g e。

FTB790系列流量计说明书

FTB790系列流量计说明书

Turbine FlowmeTers wiTh local DigiTal DisplayFTB790 SeriesFTB790 Series turbine meters with microprocessor-based electronics offers a durable, compact, high-precision fluidmeasurement device, with total and rate indication. Information is clearly displayed on a large 6-digit liquid crystal display with only 2-point floating decimal for totals from 0.01 to 999,999. All operations are easily performed with only 2 buttons. The basic unit and display are powered by 2 lithium batteries, providing up to 5 years of use. Cumulative total, batch total, and rate of flow are standard. A single-point field calibration curve can be stored in memory. The turbine meter can also beordered without displayelectronics. A special pulseoutput model (FLSC790-P-ND)must be ordered to obtain an open collector current sinking outputoperated on 9 to 35 Vdc. Theoutput is a square wave pulsewith a 3-wire connection.Accessories for Turbine Meters With the Display: The FLSC790-MA provides a 4 to 20 mA or 0 to 5 Vdc output for rate indication. The output module requires field calibration. The 4 to 20 mA dc is a 2-wire system requiring 8 to 30 Vdc power (24 Vdc recommended).The FLSC790-P pulse outputmodule provides an unscaled open collector sinking output operatingon an applied voltage of 0 to 60 Vdc. The output is a square wave pulse with an amplitude the same as the supplied voltage. The FTB790-RK remote kit allows remote mounting of display electronics. This option expands the applications into wider fluidtemperature ranges to -40 to 121°C (-40 to 250°F). The LCD display can be mounted up to 90 m (300') from the turbine meter.The FLSC790-90D is a 90°mounting adaptor designed to allow displays to be mounted 90° from the standard position.G2S20N09GMBG2S15N09GMBG2S05N09GMAG2S07N09GMAG2S10N09GMAAll models shown smaller than actual size.F-61U I ndicates Both Rate and Total UU p to 1% Reading AccuracyU 6-Digit Display U S ignal Output Capabilities UG PM or LPM (Field Selectable)UB attery Operated (Included)U P VDF (FTB890) or PVC (FTB690) ModelsAlso Available** Extended low flow range and field calibration for viscosity not available on “-ND ” (no display) units.For units with ISO threads add “-ISO” to the model number, for additional cost.For units with T ri-Grip mounting add “-TRI” to model number, for additional cost.For high pressure units [207 bar (3000 psig)], add suffix “-HP” to model number, for additional cost.SPECIFICATIONSAccuracy:G2S05N09GMA : ±2% rdg G2S07N09GMA,G2S10N09GMA : ±1.5% rdg G2S15N09GMB,G2S20N09GMB : ±1.0% rdgExtended Low Flow Range Accuracy: ±5.0% of reading (display models only)Repeatability: ±0.1%Pressure Rating: 1500 psig (103 bar)With “-HP” Option: 3000 psig (207 bar)Except as noted, options and accessories are for display models only. Only one module can be installed per unit. Comes complete with two 3V lithium batteries and operator’s manual.† Comes complete with 3 m (10') cable, and operator’s manual.Ordering Examples: G2S10N09GMA , 1" turbine meter, with FLSC790-MA , field installable 4 to 20 mA dc output.F-62FTemperature Range:With Remote Electronics Kit: -40 to 121°C (-40 to 250°F)Without Remote Electronics: -10 to 60°C (14 to 140°F)Viscosity: Rated accuracy for fluids withviscosity of water (1 cSt); meters with display can be used for fluids up to 100 cSt with field calibration Wetted Components: Housing: 316 SSJournal Bearings: Ceramic (96% alumina)Shaft: T ungsten carbideRotor and Supports: PVDF Retaining Rings: 316 SSDisplay: 6-Digit LCD indicates flow rate, batch and cumulative total Battery Life: 5 yearsFM Approvals: T urbine meters with display and no accessories are FM approved for Class 1, Div. 1 hazardous environmentsG2S05N09GMA shown larger than actual size.Note: Outputs and accessories are not designed for hazardous environments.。

Festo Didactic LabVolt Series 6080-00 流动力培训系统说明书

Festo Didactic LabVolt Series 6080-00 流动力培训系统说明书

LabVolt Series DatasheetHydraulics Training System 6080-00* The product images shown in this document are for illustration purposes; actual products may vary. Please refer to the Specifications section of each product/item for all details. Festo Didactic reserves the right to change product images and specifications at any time without notice.Festo Didactic en 120 V - 60 Hz 02/2022Hydraulics Training System, LabVolt Series••Table of ContentsGeneral Description_________________________________________________________________________________2Innovative Design __________________________________________________________________________________2Virtual Laboratory Equipment ________________________________________________________________________2Courseware _______________________________________________________________________________________3eLearning Systems _________________________________________________________________________________3Optional Manual(s)_________________________________________________________________________________4General DescriptionThe Hydraulics Training System from LabVolt was re-engineered and replaced by the two following Festo Didactic equipment sets in fluid power:Hydraulics – Basic level – TP 501 America – Equipment set Electrohydraulics – Basic level – TP 601 – Equipment setClick on the links for more information about these systems (topic coverage, list of components, etc.)Innovative DesignEngineered for extreme ease of use, the basic system comes with a work surface assembly consisting of a solid metal, universal drip-tray hinged to a perforated, tiltable work surface on which hydraulic components can be mounted.The work surface can be configured to accommodate a wide variety of space and teaching needs. Lying flat over the drip tray, or tilted at 45°, the work surface provides a large area on which hydraulic components and space-expanding work surfaces can be mounted at any location, either at 0° or 90°.Mounting and removal of components are especially easy with the Quick-Lock System that secures the component base plate to the work surface.Although the system is designed to operate atop a regular work table, an optional bench is available to provide mobility and storage space. Mounted on four heavy-duty, swivelling, lockable castors, the bench provides shelving for extra work surfaces and components. Optional dressing panels are also available to fully enclose the bench and provide storage area for the components.The work surfaces may also be linked together for more complex electro-hydraulic/pneumatic circuits. By utilizing the optional work surfaces, exercise setups can be saved.Two student groups can simultaneously work on a bench when the Work Surface (Dual A-Frame), Model 6301-1 is used. All components meet industrial safety standards, are identified with the proper ANSI symbol, and are equipped with male check-valve quick-connect fittings.Virtual Laboratory EquipmentAll components contained in subsystems Hydraulics Fundamentals and Electrical Control of Hydraulic Systems can be simulated by the Windows ®-based Hydraulics Simulation Software (LVSIM ®-HYD), Model 6385. The simulated components can be interconnected and their operation studied, using the same courseware as that used for the real equipment.Hydraulics Training System, LabVolt SeriesCoursewareThe courseware consists of a student manual for each subsystem and an instructor guide. The student manuals are divided into several units, each consisting of a series of hands-on exercises dealing with one of the hydraulics fields. Each exercise provides a clearly stated objective, a discussion, textbook references, asummary of the exercise procedure, a detailed exercise procedure, a conclusion, and a set of review questions.A ten question test at the end of each unit allows the students to verify what was learned in the unit. Refer to the tables of contents of the manuals for a list of the topics covered in the student manuals.The instructor guides contain the measurement results as well as the answers for each hands-on exercise of the student manuals, and the answers to the unit test questions.The courseware also includes a reference textbook, optional instructional DVDs, and courseware figures. These figures are available in the form of transparencies and on CD-ROM. Furthermore, all student manuals and instructor guides are available, as an option, in Job Sheet format.•••eLearning SystemsThe courseware is also available in three eLearning formats for users who prefer a computer-based approach:eSeries, facilitated by the Mind-Sight eLearning System. See Hydraulics Fundamentals eSeries, Model 6386-E, and Advanced Hydraulics eSeries, Model 6386-1.SCORM-based, designed to be hosted by a third-party, SCORM 1.2 compliant Management System. See Hydraulics Fundamentals SCORM, Model 6386-F, and Advanced Hydraulics SCORM, Model 6386-2.Stand-alone, available on CD-ROM. This format runs on a web browser and does not require any management system. See Hydraulics Fundamentals Stand-Alone, Model 6386-G, and Advanced Hydraulics Stand-Alone, Model 6386-3.1 A copy is included with the system.2 A copy is included with the system and accessible from the help menu of the software.Hydraulics Training System, LabVolt SeriesOptional Manual(s)Qty Description Model number1CNC Mill Software (User Guide) __________________________________________________ 584391 (36189-E0)11RoboCIM 5150 Software (User Guide) _____________________________________________ 580451 (39376-E0)2DescriptionManual numberHydraulics Training System, LabVolt SeriesReflecting the commitment of Festo Didactic to high quality standards in product, design, development, production, installation, and service, our manufacturing and distribution facility has received the ISO 9001 certification.Festo Didactic reserves the right to make product improvements at any time and without notice and is not responsible for typographical errors. Festo Didactic recognizes all product names used herein as trademarks or registered trademarks of their respective holders. © Festo Didactic Inc. 2022. All rights reserved.Festo Didactic SERechbergstrasse 373770 DenkendorfGermanyP. +49(0)711/3467-0F. +49(0)711/347-54-88500Festo Didactic Inc.607 Industrial Way WestEatontown, NJ 07724United StatesP. +1-732-938-2000F. +1-732-774-8573Festo Didactic Ltée/Ltd675 rue du CarboneQuébec QC G2N 2K7CanadaP. +1-418-849-1000F. +1-418-849-1666。

FBT-9型数显勃氏透气比表面积仪讲解

FBT-9型数显勃氏透气比表面积仪讲解

FBT-9型数显勃氏透气比表面积仪一、FBT-9型比表面积仪概述FBT-9型数显勃氏透气比表面积仪主要根据国家标准GB8074-87《水泥比表面积测定方法》的有关规定,并参照美国ASTMC204-75透气法改进制成。

基本原理是采用一定量的空气,透过具有一定空隙率和一定厚度的压实粉层时所受的阻力不同而进行测定的。

它主要用于测定水泥的比表面积,也可用作测定陶瓷、磨料、金属、煤炭、食品、火药等粉状物料的比表面积。

二、FBT-9比表面积仪主要参数1、透气圆筒内腔直径:φ12.7+0.05 mm2、透气圆筒内腔试料层高度:(15±0.5)mm3、穿孔板孔数:35个穿孔板孔径:φ1.0 mm穿孔板板厚:1-0.10 mm4、电磁泵工作电压:220V;周波:50HZ5、电磁泵功耗:<15VA6、电磁阀工作电压:12V7、仪器重量:约5 kg (毛重)8、外型尺寸:460 mm*220 mm*170mm(连仪器箱外型为480 mm*230 mm*190mm)三、FBT-9水泥比表面积仪使用方法及操作步骤本仪器的使用方法与操作步骤可参照GB8074-87水泥比表面积测定方法---勃氏法的有关规定进行,现摘录如下:(1)仪器的校正1、标准物料:使用比表面积接近2800cm2/g和4000 cm2/g 的标准物料对试验仪器进行校正。

标准样品在使用前应保持与室温相同。

2、试料层体积的测定测定试料层的体积用下述水银排代法A、将二片滤纸沿筒壁放入透气圆筒内,用推杆(附件一)的大端往下按,直到滤纸平正地放在穿孔板上,然后装满水银,用一薄玻璃板轻压水银表面,使水银表面与圆筒上口平齐,从圆筒中倒出水银称重,记录水银质量P1。

B、从圆筒中取出一片滤纸,然后加入适量的粉料,再盖上一层滤纸用捣器压实,直到捣器的支持环与圆筒顶边接触为止,取出捣器,再在圆筒上部空间加入水银,同上述方法使水银面与圆筒上口平齐,再倒出水银称重,记录水银质量P2。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档