Esb685
杰尼奥电子有限公司 - 泵类产品说明书
Metering pumpsTHE COMPANYDoseuro is a combination of two capabilities: the first is a solid technical knowledge, obtained during a multi-year experience in the dosing field, while the second is a commercial understanding of the changes in this field and sensitivity to our customers’ requirements. These two factors aresupported by a strong company structure that meets our customers’ demands.The continuous research and principal effort directed to the customer satisfaction are the fundamental reasons of Doseuro success, whichEach of our products speaks for itself. Highreliability is achieved by constant productdevelopment, updating production techniques,everlasting quality control and rigorous testing at allstages of production.WATER ANDEFFLUENT TREATMENTPHARMACEUTICALSAND TEXTILESHORTICULTURALAPPLICATIONS CHEMICALS ANDDYESTUFFS TANNINGPAPER INDUSTRY FOOD PRODUCTION*T h e W o r l d O v e rMAIN FEATURESAll Doseuro pumps are fitted as standard with top quality 4 pole electric motors that conform to the UNEL-MEC specifications, and range from 0.09-4.0 kW at European standard 3 phase voltages of 230/400V @ 50Hz. Non standard motors are available to many alternative specifications, including different voltages and frequencies, insulation standards, and special explosion-proof versions.The dosing rate is fully adjustable via a manually controlled eccentric cam mechanism with spring return, or positive return according to API standard 675.Automatic adjustment is available by means of servo-control motors, pneumatic control or motor frequency control, interface PROFIBUS or other BUS, if required. The reduction system, made of an endless screw coupled to a worm-wheel, makes thegearbox very strong.Our pumps are complemented by a wide range of accessories which include, foot valve/strainers, pressure relief and loading valves, injection fittings and pulsation dampeners.Special versions of construction are available to suit our clients specific applications.A VIEW OVER THE PRODUCTION RANGE Doseuro chemical dosing pumps are available in three main versions. Plunger pumps with packed plungers, plunger/hydraulic diaphragms or mechanical diaphragms. High pressure pumps are available too, upon request. The range also includes various driving methods, such as electric motor or electromagnetic solenoid operation. The company also manufactures complete dosing packages, electric mixers, and fully automatic plants for the dissolution and mixing of polyelectrolyte, both aspowder and emulsion.The most common fields of application for Doseuro chemical dosing pumps are listed in the pictures below.RUBBER AND PLASTICSOIL AND GASIRON, STEEL, COAL AND CONSTRUCTIONNAVAL AND CIVILIAN MARINEAND WHEREVER THERE IS A FLUIDMANY ENGINEERING PROJECTS* available for selected productsPositive Displacement Plunger Dosing PumpAI series plunger dosing pumps comply with mechanical and performance API 675 standards. Furthermore they comply with ATEX standard, therefore they can be installed in Hazardous area. Mechanism is an internal worm gear, fully oil bath lubricated with possibility to be coupled with others independently from the size and stroke number to obtain multi-heads unit.Stroke adjustment can be carried with the pump at rest or in operation and it can be manual or automatic through automatic actuator driven by 4-20 mA; different BUS; pneumatic. Accuracy within ± 1% within 10-100% of rated capacity.As plunger pumps they are reliable and easy for maintenance and with the possibility to have flushing or leakage recovery system (optional).Wide choice of wetted materials: S.S.316L; PVC; PP; PVDF; PTFE other materials available upon request.Fittings– Relief valves and back pressure valves– Safety relief valve– Injection valve– Foot valve– Pulsation dampeners– Calibration pot ModelMax Capacityin Lt/hMax pressurein Barg A I 17538550 A I 250126540 A I 350356940 AP A I 17544230 AP A I 250160230 AP A I 350477250 Note: higher pressure are availablePositive Displacement Sandwich Hydraulic Diaphragm Dosing pumpSDI Sandwich Hydraulic diaphragm dosing pumps comply with mechanical and performance API 675 standards.Furthermore they comply with ATEX standard, therefore they can be installed in Hazardous area. Mechanism is an internal worm gear, fully oil bath lubricated with possibility to be coupled with others independently from the size and stroke number to obtain multi-heads unit.Stroke adjustment can be carried with the pump at rest or in operation and it can be manual or automatic through automatic actuator driven by 4-20 mA; different BUS; pneumatic. Accuracy within ± 1% within 10-100% of rated capacity.A built-in safety valve is installed in the hydraulic circuit, in order to protect the diaphragm against over pressure. The peculiarity of this pump is the special sandwich diaphragm and the reliability of the diaphragm rupture detection system.Wide choice of wetted materials: S.S.316L; PVC; PP; PVDF; PTFE other materials available upon request.Fittings– Relief valves and back pressure valves– Safety relief valve– Injection valve– Foot valve– Pulsation dampeners– Calibration pot ModelMax Capacityin Lt/hMax pressurein Barg SD I 17539014 SD I 250126414 SD I 350402814 AP SD I 17523140 AP SD I 25071180 AP SD I 350149656 Note: higher pressure are availableSpring Return Plunger Dosing PumpA Plunger metering pumps are normally used when:– The dosed liquid is non abrasive solution– A drip proof system is not essential– High pressure is requiredEach pump is fitted with a standard gearbox reduction system with a vertical mounted motor.The reduction gearbox is of a standard endless screw plus worm-wheel type, supported by bearing, fully lubricated in oil bath.Stroke adjustment can be carried with the pump at rest or in operation and it can be manual or automatic through automatic actuator driven by 4-20 mA; different BUS; pneumatic.As plunger pumps they are reliable and easy for maintenance and with the possibility to have flushing or leakage recovery system (optional).Furthermore they comply with ATEX standard, therefore they can be installed in Hazardous area. Wide choice of wetted materials: S.S.316L; PVC; PP; PVDF; PTFE other materials available upon request.Fittings– Polyethylene tanks– Relief valves and back pressure valves– Safety relief valve– Injection valve– Foot valve– Pulsation dampeners– Calibration pot ModelMax Capacityin Lt/hMax pressurein Barg A125N15620 A175N40820 A250N104220 A350N14584 AP A125N15.6230 AP A175N28.6230 AP A250N57.4230Spring Return Mechanical Diaphragm Dosing PumpD mechanical diaphragm metering pumps are normally used when:– The dosed liquid contains small amounts of suspended solids– A drip proof/air tight application is required– The dosed liquid is a toxic solutionEach pump is fitted with a standard gearbox reduction system with a vertical mounted motor. The reduction gearbox is of a standard endless screw plus worm-wheel type, supported by bearing, fully lubricated in oil bath.Stroke adjustment can be carried with the pump at rest or in operation and it can be manual or automatic through automatic actuator driven by 4-20 mA; different BUS; pneumatic.As mechanical diaphragm they are easy for maintenance.Furthermore they comply with ATEX standard, therefore they can be installed in Hazardous area. Wide choice of wetted materials: S.S.316L; PVC; PP; PVDF; PTFE other materials available upon request.Fittings– Polyethylene tanks– Relief valves and back pressure valves– Safety relief valve– Injection valve– Foot valve– Pulsation dampeners– Calibration pot ModelMax Capacityin Lt/hMax pressurein Barg D050N4914 D100N4385 D101N4188 D121N5703 D122N14006Spring Return Hydraulic Diaphragm Dosing PumpB & BR Hydraulic diaphragm metering pumps are normally used when:– The dosed liquid contains small amounts of suspended solids– A drip proof/air tight application is required– The dosed liquid is a toxic solution– High pressure is requiredEach pump is fitted with a standard gearbox reduction system with a vertical mounted motor. The reduction gearbox is of a standard endless screw plus worm-wheel type, supported by bearing, fully lubricated in oil bath.Stroke adjustment can be carried with the pump at rest or in operation and it can be manual or automatic through automatic actuator driven by 4-20 mA; different BUS; pneumatic.BR version is equipped with built-in safety valve is installed in the hydraulic circuit, in order to protect the diaphragm against over pressure.Furthermore they comply with ATEX standard, therefore they can be installed in Hazardous area. Wide choice of wetted materials: S.S.316L; PVC; PP; PVDF; PTFE other materials available upon request.Fittings– Polyethylene tanks– Relief valves and back pressure valves– Safety relief valve– Injection valve– Foot valve– Pulsation dampeners– Calibration pot ModelMax Capacityin Lt/hMax pressurein Barg B & BR 125N10820 / 13.5 B & BR 175N41820 / 14 B & BR 250N106811 / 7.2 AP B & BR 125N6060 / 40 AP B & BR 175N24760 / 40 AP B & BR 250N55623 / 20.7Spring Return Sandwich Hydraulic Diaphragm Dosing PumpSD Sandwich Hydraulic diaphragm metering pumps are normally used when:– The dosed liquid contains small amounts of suspended solids– No leakage are accepted– The dosed liquid is a toxic solution– High pressure is requiredEach pump is fitted with a standard gearbox reduction system with a vertical mounted motor. The reduction gearbox is of a standard endless screw plus worm-wheel type, supported by bearing, fully lubricated in oil bath.Stroke adjustment can be carried with the pump at rest or in operation and it can be manual or automatic through automatic actuator driven by 4-20 mA; different BUS; pneumatic.A built-in safety valve is installed in the hydraulic circuit, in order to protect the diaphragm against over pressure. The peculiarity of this pump is the special sandwich diaphragm and the reliability of the diaphragm rupture detection system.Furthermore they comply with ATEX standard, therefore they can be installed in Hazardous area. Wide choice of wetted materials: S.S.316L; PVC; PP; PVDF; PTFE other materials available upon request.Fittings– Polyethylene tanks– Relief valves and back pressure valves– Safety relief valve– Injection valve– Foot valve– Pulsation dampeners– Calibration pot ModelMax Capacityin Lt/hMax pressurein Barg SD 125N10813.5 SD 175N41814 SD 250N10687.2 AP SD 125N6040 AP SD 175N24740 AP SD 250N55620.7Spring Return Mechanical Diaphragm Dosing PumpFM mechanical diaphragm metering pumps are normally used when:– The dosed liquid contains small amounts of suspended solids– A drip proof/air tight application is required– The dosed liquid is a toxic solutionEach pump is fitted with a standard gearbox reduction system with a vertical mounted motor. The reduction gearbox is of a standard endless screw plus worm-wheel type, supported by bearing.Stroke adjustment can be carried with the pump at rest or in operation and it can be manual. As mechanical diaphragm they are easy for maintenance.Peculiarity of this model is the complete plastic casing suitable for ACID environment.Wide choice of wetted materials: S.S.316L; PVC; PP; PVDF; PTFE other materials available upon request.Fittings– Polyethylene tanks– Relief valves and back pressure valves– Safety relief valve– Injection valve– Foot valve– Pulsation dampeners– Calibration pot ModelMax Capacityin Lt/hMax pressurein Barg FM 050N-301410 FM 050N-50475Solenoid Dosing PumpsThe SDP family provide an alternative solution in lower rates application field where end users look forward reliable results and simple operation.Using a built-in microprocessor, with its own flexibility, makes the SDP series extremely complete and suitable for a wide range of applications, thanks to several functions included in the same pump, even with few models.Common features for every model:– Foot mounted dosing pump– Corrosion-proof reinforced polypropylene housing– Solid PTFE diaphragm– Water-resistant IP65 protection– Wide choice of wetted materials: PP; PVC; PTFE; PVDF– Standard power supply: 230V 50/60 HzOn request: 24V d.c., 12V d.c., 24V a.c.,110V 50/60 HzAll chemical dosing pumps are complete of accessories to improve theoperation and accuracy of the chemical dosing pump:– Injection valve– 1.5 mt suction pipe; 1.5 mt delivery pipe– StrainerFittings– Polyethylene tanks– Relief valves and back pressure valves– Safety relief valve– Injection valve– Foot valve– Pulsation dampeners– Calibration pot ModelMax Capacityin Lt/hMax pressurein Barg S - - 2020Automatic plants for dissolution and preparation of powder/emulsion polyelectrolytesThese plants produce from 300 to 5000 lt/h of fully polyelectrolyte solution at constant solution strength from powder /emulsion stock. Their compact design in Stainless steel AISI 304 or High Density PolyPropylene includes all necessary controls for water make up and polymer feed and incorporates the following equipment and features:– Dissolution, diluition and ageing tanks.– Polymer and water feed rate controls.– All mixers.– Control panel, fitted and fully interwired.– Polyelectrolyte chemical dosing pumps.The Powder dilution plant is fitted with a stocking hopper and a volumetricendless screw, while the Emulsion dilution plant works thanks to aPlunger metering pump, dosing the Emulsion into a static mixer.Model Version Max Capacity in Lt/h HA Powder5000 HE Emulsion5000 Note: higher capacity are availableDEM DMT DRCDRV Electric mixers for chemical mixing Type DMT and type DMMHigh speed mixers directly coupled to the motor, for small tanks up to 1000 litres capacity, with polypropylene coated shaft and propeller.Type DEMHigh speed mixers, directly coupled to the motor, supported by a protection lantern, housing an extra bearing kit, for increased shaft stability, and an extra seals kit, for increased protection from the mixed chemical.Type DRVSlow speed mixers for light applications, with close coupled worm wheel/endless screw reduction gear box.Type DRCHeavy duty slow speed mixers with co-axial reducer, outrigger bearings and protective seals.ModelVersion ServiceDMTFast mixer ≤ 1000Lt tank liquid ≤ 250cps DMM Fast mixer ≤ 1000Lt tank liquid ≤ 250cps DEMFast mixer ≤ 3000Lt tank liquid ≤ 1000cps DRV Slow mixer ≤ 7000Lt tank liquid ≤ 2500cps DRC Slow mixer≤ 40000Lt tank liquid ≤ 5000cpsPolyethylene tanksSuitable to be fitted with metering pump on its topRelief valves and back pressure valvesSafety relief valvePulsation dampener Type: HSTXBody in S.S.316, composed by two parts assembled together by means of a special hosing that, under dynamic pressures, tends to close itself.Various diaphragm materials available, for wide chemical compatibility. Built accordingly to the ASME VIII° Div. 1 rules.Pulsation dampenerType: HSTPVCBody in PVC, composed by two parts assembled together by means of a special hosing that, under dynamic pressures, tends to close itself.Maximum temperature: + 50 °C. Various diaphragm materials available, for wide chemical compatibility.FILTERSBACK PRESSUREVALVESPULSATION DAMPENERSCert. n° 5942。
Bosch 电子消毒器说明书
Accessories: To purchase Bosch accessories, cleaners & parts please visit /us/store or call 1-800-944-2904 (Mon to Fri 5 am to 6 pm PST, Sat 6 am to 3 pm PST).SPE53B56UCBlackAlso available in:Stainless Steel SPE53B55UC White SPE53B52UC The 18" wide dishwasher perfectly fits in compact spaces.46 dBA: dishwasher runs quietly so your kitchen conversations aren’t interrupted.Get hands-free voice operation with Amazon Alexa or Hey Google, smart reordering of detergent tabs via the Amazon Alexa app, plus so much more —all with the Home Connect™ app on your smartphone.3rd rack provides theperfect space for silverware and large utensils while its V shape leaves room below for taller items.The Favorite button allows you to easily access your preferred cycle/option combination with 1 touch.AquaStop Plus® detects leaks with a dual sensor system, and then contains them for premium protection.Accessories: To purchase Bosch accessories, cleaners & parts please visit /us/store or call 1-800-944-2904 (Mon to Fri 5 am to 6 pm PST, Sat 6 am to 3 pm PST).Installation DetailsJunction box accessoryInstallation DetailsAccessories: To purchase Bosch accessories, cleaners & parts please visit /us/store or call 1-800-944-2904 (Mon to Fri 5 am to 6 pm PST, Sat 6 am to 3 pm PST).。
NI 9216 9226 8通道、400采样 秒聚合、0Ω至400Ω 4000Ω、PT100 RTD
CALIBRATION PROCEDURENI 9216/92268-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω/4000 Ω,PT100RTD/PT1000 RTD C Series Temperature Input ModuleThis document contains the verification and adjustment procedures for the NI9216 and NI 9226. In this document, the NI9216 and NI9226 are inclusively referred to as NI9216/9226. For more information about calibration solutions, visit /calibration.Contents Software (1)Documentation (2)Test Equipment (3)Test Conditions (3)Initial Setup (3)Verification (4)Accuracy Verification (4)Adjustments (6)Accuracy Adjustment (6)EEPROM Update (7)Reverification (7)Accuracy Under Calibration Conditions (7)Worldwide Support and Services (8)SoftwareCalibrating the NI 9216/9226 requires the installation of NI-DAQmx 14.5 or later on the calibration system. You can download NI-DAQmx from /downloads. NI-DAQmx supports LabVIEW, LabWindows™/CVI™, ANSI C, Microsoft Visual C++, Microsoft Visual Basic .NET, and Microsoft Visual C#. When you install NI-DAQmx you only need to install support for the application software that you intend to use.2| |NI 9216/9226 Calibration ProcedureDocumentationConsult the following documents for information about the NI 9216/9226, NI-DAQmx, and your application software. All documents are available on and help files install with the software.NI cDAQ-9174/9178 Quick Start Guide NI-DAQmx installation and hardware setup NI 9216 Getting Started Guide NI 9216 connection information NI 9216 DatasheetNI 9216 circuitry and specifications NI 9226 Getting Started Guide NI 9226 connection informationNI 9226 DatasheetNI 9226 circuitry and specificationsNI-DAQmx ReadmeOperating system and application software support in NI-DAQmx LabVIEW HelpLabVIEW programming concepts and reference information about NI-DAQmx VIs and functionsNI-DAQmx C Reference HelpReference information for NI-DAQmx C functions and NI-DAQmx C properties NI-DAQmx .NET Help Support for Visual StudioReference information for NI-DAQmx .NET methods and NI-DAQmx .NETproperties, key concepts, and a C enum to .NET enum mapping tableNI 9216/9226 Calibration Procedure|© National Instruments|3Test EquipmentTable 1 lists the equipment recommended for the performance verification and adjustment procedures. If the recommended equipment is not available, select a substitute using the requirements listed in Table 1.Test ConditionsThe following setup and environmental conditions are required to ensure the NI 9216/9226 meets published specifications.•Keep connections to the device as short as possible. Long cables and wires act as antennas, picking up extra noise that can affect measurements.•Verify that all connections to the device are secure.•Use shielded copper wire for all cable connections to the device. Use twisted-pairs wire to eliminate noise and thermal offsets.•Maintain an ambient temperature of 20°C to 28°C.•Keep relative humidity below 80%.•Allow a warm-up time of at least 10minutes to ensure that the NI 9216/9226 measurement circuitry is at a stable operating temperature.Initial SetupComplete the following steps to set up the NI 9216/9226.1.Install NI-DAQmx.2.Make sure the cDAQ-9178 power source is not connected to the chassis.3.Connect the cDAQ-9178 chassis to the system safety ground.a.Attach a ring lug to a 14 AWG (1.6mm) wire.b.Connect the ring lug to the ground terminal on the side of the cDAQ-9178 chassis using the ground screw.c.Attach the other end of the wire to the system safety ground.4.Install the module in slot 8 of the cDAQ-9178 chassis. Leave slots 1 through 7 of the cDAQ-9178 chassis empty.5.Connect the cDAQ-9178 chassis to your host computer.Table 1. Recommended EquipmentEquipmentRecommendedModelsRequirementsCalibrator Fluke 5522AUse a high-precision resistance source with gain accuracy ≤40 ppm and offset error ≤2 m Ω for the NI 9216 and offset error ≤20 m Ω for the NI 9226.Chassis cDAQ-9178—6.Connect the power source to the cDAQ-9178 chassis.unch Measurement & Automation Explorer (MAX).8.Right-click the device name and select Self-Test to ensure that the module is workingproperly.VerificationThe following performance verification procedure describes the sequence of operation and test points required to verify the NI 9216/9226. The verification procedure assumes that adequate traceable uncertainties are available for the calibration references.Accuracy VerificationComplete the following procedure to determine the As-Found status of the NI9216/9226.1.Set the calibrator to Standby mode (STBY).2.Connect the desired channel of the NI 9216/9226 to the calibrator as shown in Figure 1.Connect only one channel at a time.Figure 1. 4-Wire Resistance Connections3.Set the calibrator as a resistance source to a Test Point value indicated in Table 2.4.Set calibrator COMP to 4-wire.Table 2. NI 9216/9226 Accuracy Verification Test LimitsModuleRange Test Point1-Year Limits Minimum(Ω)Maximum(Ω)Value (Ω)UpperLimit (Ω)LowerLimit (Ω)NI 9216040000.03-0.03 100100.04299.958 320320.0684319.9316NI 92260400000.3-0.3 10001000.43999.57 32003200.723199.284||NI 9216/9226 Calibration ProcedureNI 9216/9226 Calibration Procedure |© National Instruments |5Note The limits are only based on the NI 9216/9226 accuracy. The uncertainty ofcalibration standard is not included.NoteThe test limits listed in Table 2 are derived using the values in Table 6.5.Set the calibrator to Operate mode (OPR).6.Acquire and average samples from one channel.a.Create and configure a 4-wire AI resistance task on the NI 9216/9226 according to Table 3.b.Configure the ADC Timing Mode to High Resolution.NoteUse appropriate channel number in place of “x” in “AIx.” For example, useAI3 for channel 3.c.Configure the task timing according to Table 4.d.Start the task.e.Read the samples from the NI 9216/9226.f.Average the samples.g.Stop and clear the task.pare the per-channel averages to the limits in Table 2.8.Set the calibrator to Standby mode (STBY).9.Repeat steps 3 through 8 for each test point listed in Table 2.10.Disconnect the NI 9216/9226 channel from the calibrator.11.Repeat steps 2 through 10 for any other desired channel of NI 9216/9226.Table 3. NI 9216/9226 Voltage ConfigurationModulePhysical ChannelRangeMinimum (Ω)Maximum (Ω)NI 9216AIx 0400NI 9226AIx4000Table 4. NI 9216/9226 Task Timing ConfigurationSample Mode Samples Per ChannelRate (S/s)Finite Samples 1056| |NI 9216/9226 Calibration ProcedureAdjustmentsThe following performance adjustment procedure describes the sequence of operation required to adjust the NI 9216/9226.Accuracy AdjustmentComplete the following procedure to adjust the accuracy performance of the NI 9216/9226.1.Set the calibrator to Standby mode (STBY).2.Connect the desired channel of the NI 9216/9226 to the calibrator as shown in Figure 1. Connect only one channel at a time.3.Adjust the desired channel of the NI 9216/9226.a.Initialize a calibration session on the NI 9216/9226. The default password is NI .b.Input the external temperature in degrees Celsius.c.Call the DAQmx Get NI 9216/9226 Calibration Adjustment Points function to obtain an array of recommended calibration resistance values.d.Set the calibrator to a reference value determined by the array of recommended calibration voltages.e.Set calibrator COMP to 4-wire.f.Set the calibrator to Operate mode (OPR).g.Call and configure the NI 9216/9226 adjustment function according to Table 5.Note Use appropriate channel number in place of “x” in “AIx.” For example, useAI3 for channel 3.NoteThe module acquisition is started each time the adjust function is called.h.Set the calibrator to Standby mode (STBY).i.Repeat steps d through h for each point in the array.j.Close the calibration session with action commit.4.Disconnect the NI 9216/9226 channel from the calibrator.5.Repeat steps 2 through 4 to calibrate any other desired channel of NI 9216/9226.Table 5. Gain Adjustment ConfigurationPhysical Channel Reference ValueAIxThe reference resistance value from the arrayof adjustment pointsNI 9216/9226 Calibration Procedure |© National Instruments |7EEPROM UpdateWhen an adjustment procedure is completed, the NI 9216/9226 internal calibration memory (EEPROM) is immediately updated.If you do not want to perform an adjustment, you can update the calibration date and onboard calibration temperature without making any adjustments by initializing an external calibration , setting the C Series calibration temperature, and closing the external calibration.ReverificationRepeat the Verification section to determine the As-Left status of the device.NoteIf any test fails Reverification after performing an adjustment, verify that youhave met the Test Conditions before returning your device to NI. Refer to Worldwide Support and Services for assistance in returning the device to NI.Accuracy Under Calibration ConditionsThe values in the following table are based on calibrated scaling coefficients, which are stored in the onboard EEPROM.The following accuracy table is valid for calibration under the following conditions:•Ambient temperature 20°C to 28°C•NI 9216/9226 installed in slot 8 of an cDAQ-9178 chassis •Slots 1 through 7 of the cDAQ-9178 chassis are emptyNoteFor operational specifications, refer to the most recent NI 9216 Datasheet orNI 9226 Datasheet online at /manuals .Table 6. NI 9216/9226 Accuracy Under Calibration ConditionsModule Gain Error Offset ErrorNI 9216±0.012%±0.03 ΩNI 9226±0.013%±0.3Ω©2015–2018 National Instruments. All rights reserved. 375425C-01Oct18Refer to the NI Trademarks and Logo Guidelines at /trademarks for more information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NationalInstruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patents Notice at /patents . You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at /legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.Worldwide Support and ServicesThe NI website is your complete resource for technical support. At /support you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers.Visit /services for NI Factory Installation Services, repairs, extended warranty, and other services.Visit /register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI.NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas,78759-3504. NI also has offices located around the world. For telephone support in the United States, create your service request at /support or dial 1866ASK MYNI (2756964). For telephone support outside the United States, visit the Worldwide Offices section of/niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events.。
Series 6 电磁炉说明书
Series 6, Induction hob, 60 cm, Black, surface mount without frame PVQ651FC5EHEZ390090 Wok para radiantes e inducciónHEZ390210 Sartén antiadherente de 15 cm. de base. HEZ9ES100 Cafetera 4 tazasHEZ9FE280 Sartén de hierro Ø 18 / 28 cmHEZ9SE040 set de 4 piezasHEZ9SE060 set de 6 piezas Encimera de inducción con PerfectFry: logra resultados de fritura perfectos gracias al control automático de temperatura.• DirectSelect: Directo, simple selección de la zona de cocción deseada, potencia y funciones adicionales.• CombiZone: más flexibilidad al combinar dos zonas de cocción para cocinar con distribución uniforme del calor, para asadores y similares.• PerfectFry: Para un perfecto dorado de los alimentos gracias al control del sensor con 4 niveles de potencia con ajuste automático• Terminación biselada: diseño limpio con cristal biselado en la parte delantera y los laterales.• PowerBoost: hasta un 50% más de potencia para una cocción más rápida.Familia de Producto: ..........................Placa independie.vitrocerámica Tipo de construcción: .........................................................Integrable Entrada energética: ...............................................................Eléctrico Número de posiciones que se pueden usar al mismo tiempo: . (4)Medidas del nicho de encastre: ...............51 x 560-560 x 490-500 mm Anchura: .................................................................................592 mm Dimensiones aparato (alto, ancho, fondo): ...........51 x 592 x 522 mm Medidas del producto embalado: ........................126 x 753 x 608 mm Peso neto: ...............................................................................11.7 kg Peso bruto: ..............................................................................13.9 kg Indicador de calor residual: .................................................Separado Ubicación del panel de mandos: ...............Frontal de la vitrocerámica Material de la superficie básica: ....................................Vitrocerámica Color de superficie superior: .....................................................Negro Longitud del cable de alimentación eléctrica: ......................110.0 cm Sealed Burners: ..............................................................................No Zonas con booster: ....................................................................Todas Potencia del segundo elemento calentador: ............................3.6 kW Power of heating element (kW in boost): ..............................[3.7] kW Potencia: .................................................................................7400 W Tensión: ..............................................................................220-240 V Frecuencia: ..........................................................................50; 60 Hz Entrada energética: ...............................................................Eléctrico Tipo de clavija: ..................................................................sin enchufe Appliance Dimensions (h x w x d) (in): ..........................................x x Dimensions of the packed product: ....................4.96 x 23.93 x 29.64 Net weight: .........................................................................26.000 lbs Gross weight: .....................................................................31.000 lbs Número de posiciones que se pueden usar al mismo tiempo: . (4)Longitud del cable de alimentación eléctrica: ......................110.0 cm Medidas del nicho de encastre: ...............51 x 560-560 x 490-500 mm Dimensiones aparato (alto, ancho, fondo): ...........51 x 592 x 522 mm Medidas del producto embalado: ........................126 x 753 x 608 mm Peso neto: ...............................................................................11.7 kg Peso bruto: ..............................................................................13.9 kgSeries 6, Induction hob, 60 cm,Black, surface mount without frame PVQ651FC5EEncimera de inducción con PerfectFry: logra resultados de fritura perfectos gracias al control automático de temperatura.Prestaciones profesionalesDiseño:- Terminación biseladaRapidez:- Función Sprint en todas las zonasConfort:- 4 zonas de inducción- DirectSelect con 17 niveles de cocción- 2 Combi zones- 2-steps- Sensores touchControl- Programación de tiempo de cocción para cada zona y avisador acústico- Avisador acústico- sí- síPotencia y tamaño:- Regulación electrónica con 17 niveles de potenciaSeguridad:- Indicador de calor residual dual (H/h)- Main Switch- Detección de recipiente- Posibilidad de limitar la potencia total de la encimera- Desconexión de seguridad de la placa- Bloqueo de seguridad para niños automático o manual- Función Clean: bloqueo temporal del control- Display de consumo de energíaMedidas:- Dimensiones para instalación: (Al/An/F) 51 mm x 560 mm x 490 mm- Dimensiones del producto: (An/F) 592 mm x 522 mm- Min. espesor de mesa: 16 mm- Cable incluido- Potencia de conexión: 7.4 kwSeries 6, Induction hob, 60 cm, Black, surface mount without frame PVQ651FC5E。
OmniSwitch 6850E产品彩页
272970
OS6850E-24X
270735
OS6850E-48
253153
OS6850E-48X
242611
OS6850E-U24X
290159
* 最大耗电量。不包括接入到 PoE 端口的设备耗电量。 ** 在满传输负载下
● 湿度(运行和存储):5% 至 95% 非冷凝 ● 在 -5℃至 +55℃、5% 至 90% 相对湿度(RH)环境下,对每
播交换,DHCP 侦听 /82 选项,ITU-T
Y.1731,IEEE 802.1ag
阿尔卡特朗讯 OmniSwitch 6850E 交换机型号 OmniSwitch 6850E 系列为客户提供多种千兆固定配置交换机选择,包括多达 4 条 10GigE 的上行线路,PoE 和电源选项,可满 足大部分需求。所有型号均为 1U 高,提供 2 个 10GBase-CX4 端口,可用于堆叠或替换为 2 端口 10 Gigabit SFP+ 模块。
OS6850E-U24X OS6-XNI-U2
特性
优势
多样特性和型号提供 :
OmniSwitch 6850 系列拥有各种的接口和型
- 千兆和万兆接口
号,可满足任何客户配置需求,提供卓越的
- IEEE 802.3af 和 802.3at 兼容的 PoE 投资保护和灵活性,同时简化部署、运营和
- 可选的 10GigE 模块,提供 2 个 10GigE 维护
描述
尺寸
OS6850E-BP-D
模块化的 120W 48-V DC 电源。为非 PoE 设备提供系 16×17.5×4.4cm
统电源
(6.3×6.9×1.73 in)
e-lins H685系列路由器规格说明书
H685系列路由器规格说明书H685系列路由器是伊林思科技有限公司基于无线网络需求,采用最新硬件系统平台,使用Linux软件系统引用最新技术研发出来的一款全新的,性能更为优异的物联网无线通信路由器产品。
采用工业级设计标准,它主要应用于行业用户的数据传输业务。
该产品采用高性能的32位嵌入式处理器,内嵌完备的TCP/IP协议栈,同时提供RS串口和10/100M以太网接口。
集成IO端子座,提供串口或者GPIO接口。
串口分别提供RS-232、RS-485、TTL电平接口的透明传输模式,支持的VPN 通信功能,采用IPSec/PPTP/L2TP/GRE VPN技术,企业级VPN隧道技术和防火墙技术,保证高安全性行业的数据安全,支持自动在线检测,实时动态刷新网络状态,保持链路畅通,产品以性能稳定、体积小、易于安装嵌入、抵抗环境能力强等优点,深受用户欢迎。
支持WEB/Telnet/Console多种配置方式,其中用户面对的是WEB图形化管理配制界面,管理方便简单。
该产品已广泛应用于物联网产业链中的M2M 行业,如智能电网、智能交通、智能家居、金融、移动POS 终端、供应链自动化、工业自动化、智能建筑、消防、公共安全、环境保护、气象、数字化医疗、遥感勘测、军事、空间探索、农业、林业、水务、煤矿、石化等领域。
金融:银行储蓄点机房监控,移动性证券交易和信息查询通信:电信机房动力环境监控,通信维护人员线路资料查询交通:GPRS/SMS/GPS 机动车辆监控调度系统;银行运钞车,邮政运输车监控调度。
公安:公安、110、交警车辆监控调度,公安移动性数据(身份证、犯罪档案等)查询,交警移动通信数据(车辆、司机档案等)查询。
热力:热力系统实时监控和维护电力:电力系统城市中电网实时监控和自动补偿,远程自动抄表公司:移动办公及管理,其他外勤人员移动性数据查询工业:工业遥感,遥测,遥控信息回报气象:气象数据采集与传输水利:水文监测生活:煤气调压站实时数据采集自动控制,自来水,污水管道,闸门、泵站与水厂实时监控维护电子商务:支持B2B、B2C的电子商务和电子支付、股票交易等。
员工满意度管理制度
员工满意度管理规范1目的为了提高员工满意度和员工忠诚度,及时调查员工满意度和分析改进,制定本员工满意度管理制度。
2范围适用于本公司所有员工。
3权责由人力资源部负责员工满意信息的收集、分析、检讨、改进;相关部门配合人力资源部进行员工满意度调查.4定义4.1员工满意(ES):是指一个员工通过对企业可感知的效果与他的期望值相比较后所形成的感觉状态。
4.2员工满意度(ESB):员工接受企业的实际感受与其期望值比较的程度(员工满意度=实际感受/期望值).5工作程序5.1由人力资源部制定员工满意信息资料收集的计划,按计划每年最少做一次问卷调查,问卷调查必须实事求是,所有问卷信息必须保密,对收集到的员工满意信息进行整理、归类、分类存放作为档案保存;5.2设计员工满意度调查表;5.3由人力资源部根据企业经营情况,自行或者委托外部机构设计《员工满意度调查表》中每个因素即为一道问题.员工满意度调查问卷设计的六个维度:a)组织认同满意度;b)管理水平满意度;c)工作回报满意度;d)工作内容满意度;e)工作关系满意度;f)工作环境满意度;g)培训、职业发展满意度.5.3.1调查表由总裁审核无误后予以进行,正式的调查表依文件的方式纳入体系中。
5.3.2调查表的内容设计要适用于公司各个方面。
5.4进行满意度调查5.4.1调查时机:a)员工满意度调查活动每年不少于1次,一般安排在每年六月,十一月进行.b)列情况发生时可适当安排员工满意度调查:c)组织结构发生变化时;d)员工变动频繁、流动率大时;e)员工不停地抱怨企业和管理人员,工作效率降低时;f)其它认为有调查需要的情况发生时。
g)其他重大事件出现时或者总裁提议进行时.5.4.2员工满意度调查是全体员工的普查而不是少数的抽查;员工满意度调查结果的好与坏是衡量企业管理工作的一个重要指标。
5.4.3由人力资源部负责制定员工满意度调查通知和流程,经总裁审核、批准后正式发出,通知中需明确调查时间等内容。
SD6855 6 LED驱动原边控制开关电源说明书
杭州士兰微电子股份有限公司
Http: //
版本号:0.2 2010.11.01 共7页 第7页
IPK ;
ISP 为次级线圈的峰值电流,IPK 为原级线圈的峰值电流,n 为原次级线圈的匝比。 因此,在峰值电流恒定的条件下,只需要保持 TOFF1=TOFF2+TON 即可实现输出的恒流。
杭州士兰微电子股份有限公司
Http: //
版本号:0.2 2010.11Fra bibliotek01 共7页 第4页
版本号:0.2 2010.11.01 共7页 第2页
SD6855/6 说明书
极限参数(除非特殊说明, Tamb=25°C)
参
数
供电电压
内部电源电压
FB输入电压
其他输入电压
输入电流
工作结温
工作温度
贮存温度
ESD(人体模式)
符号 VCC VREF5V VFB VIN
IIN TJ Tamb TSTG ESD
关断阈值电压
内部供电电源
反馈部分
使能开启电压
过压保护电压
环路开路保护电压
动态特性部分
前沿消隐时间
过压保护恢复时间
限流部分
峰值电流检测阈值
过温保护部分
过热检测
过热迟滞
符号
测试条件
IST IOP VST VSP VREF5V
VCC =14V
VEN VOVP VBLANK
TLEB TOVP
VPK
Tsd Tsdhys
Http: //
版本号:0.2 2010.11.01 共7页 第3页
SD6855/6 说明书
功能描述
SD6855/6是离线式高端开关电源控制器。通过检测变压器原级线圈的导通时间TON、副边线圈放电的时 间TOFF1和衰减振荡的时间TOFF2,来实现输出恒流。
DS-DB数字系列分布式板及音频控制系统用户手册说明书
DS-DBDigital Series Distribution BoardDN-60565:BGeneralThe DS-DB Digital Series Distribution Board and its associ-ated amplifiers provide bulk amplification capability to theDigital Voice Command (DVC) system while retaining digitalaudio distribution capabilities. Up to four DS-AMP/E amplifi-ers can supply high-level risers spread throughout an instal-lation.The DS-DB converts digital audio to analog and routes it toaudio amplifiers and optional backups. The amplifiers sendback high-level audio, which the DS-DB routes to its risers.Control and status information passes between the DS-DBand its components via DS-BUS. The DS-DB communicateswith the rest of the digital audio system through the DAL (dig-ital audio loop), and takes up two of the 32 DAL addresses. Itmay be mixed with other devices on the same DAL, such asthe DAA2 and DAX series amplifiers.An optional Firefighters’ telephone riser on the DS-DB sup-ports local and network FFT communications.Features•Input capacity of four digital audio channels.•Four low-level audio outputs for connection to amplifiers in the same cabinet.•Eight high-level audio inputs (four primary, four backup), each input capable of handling 125W of audio at 25V RMS or 100W at 70.7V RMS when used with DS-AMP.•Four Class A/eight Class B high-level 125W audio outputs, each of which can output all 125 watts from any one of the four high level primary inputs or four high-level backup inputs when used with DS-AMP.•T wo digital audio loop wire ports, which may be modified to single- or multi-mode fiber ports with fiber option mod-ules.•Local FFT riser, capable of acting as a connection on the digital FFT riser.•DS-BUS interface to communicate with local bulk amplifi-ers and power supplies.•Up to 106 seconds of standard quality backup digital mes-sage storage (from VeriFire T ools® message library, or created by the installer) for use in the event of communica-tion loss with the DVC.•Isolated alarm bus input, to be used for backup activation of alarm messages when normal communication with the DVC is lost.•Audio output activation via network control-by-event equa-tions resident within the DVC.•USB port for VeriFire Tools® communication.•Uploads and downloads via the DVC.•24 VDC input for local power.•Works with AMPS-24 power supply and battery charger.InstallationThe DS-DB arrives from the factory already installed on its chassis. The DS-DB mounts in a CAB-4 Series cabinet, as well as in an EQCAB Series backbox.One or two fiber option modules will plug directly onto a DS-DB for simple installation. A DS-BDA backup amplifier mounts directly onto a DS-DB.Specifications24 VDC Input (TB24): 0.6A alarm or standby, non-resettable. Power-limited by source, supervised. Any device connected to TB24 must be installed in the same enclosure, or within the same room in conduit.Digital Audio Ports, wire media, A and B: EIA-485 proto-col, power-limited. Maximum distance per segment is 1900 feet (579.12m) on Belden 5320UJ (18AWG, TP) FPL cable: 18AWG (0.821 mm2) twisted-pair, unshielded, power-limited. For approved cable types, see wiring documentation, PN 52916ADD, Approved Wire Cables for Digital Audio Loops. Digital Audio Ports, fib er media, fib er option modules: Digital audio loop connectors support single- and multi-mode fiber with the use of fiber option modules. Refer to the fiber option datasheet for fiber specifications.Alarm Bus: Power-limited, supervised by source. Recom-mended wiring: 14-18 AWG twisted-pair. Requires 16VDC 24VDC.FFT Riser: Power-limited output, supervised. Class A or Class B operation. Class B 2-wire connections require a 3/9k ohm 1/2 watt resistor (PN R-3.9K). Max. wiring resistance (including individual telephone zone to last handset) permit-ted is 50 ohms, 10,000 ft (3048 m) max. wiring distance at 14 AWG to last handset.DS-BUS: EI A-485 protocol, power-limited. DS-BUS points must be installed in the same enclosure or within the same room in conduit. End points require end-of-line resistors.•DS-DB endpoint: set termination switch (SW8) to ON.•DS-AMP endpoint: add 120 ohm resistor on empty TB1terminals.DN-60565:B • 11/17/2014 — Page 1 of 2Page 2 of 2 — DN-60565:B • 11/17/2014NOTIFIER® and VeriFire® Tools are registered trademarks of Honeywell International Inc.©2014 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited.This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice.For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.•AMPS-24 endpoint: resistor is present, and power supply must be an endpoint.Use 14-18 AWG, twisted unshielded wire.Audio Out: Power-limited outputs (exception: an output pro-grammed for “Riser Mode to Control Modules”, “Riser Mode to RSM-AI M Series Modules”, or “Riser Mode to CI M/CSM Series Modules” is non-power-limited.)Up to 125 Watts out-put. Supervision determined by programming. 25V RMS or 70V RMS , depending on amplifier setting. Class A or Class B operation. Class B requires 20k end-of-line resistors (included, PN ELR-20K). Class A required 10k end-of-line resistors (included, PN R-10K) on the return. 12-18 AWG twisted-pair (shielded recommended).Primary and Backup 1 through 4: Four low-level audio out-puts for connection to amplifiers. Non-power-limited inputs.Supervision programmable. Amplifiers must be installed in the same enclosure or within the same room in conduit. Rec-ommended wiring: 14-18 AWG, twisted-pair, unshielded.OUT: Four DVC-AO-level audio outputs for connection to amplifiers. Power-limited. Supervision programmable. Ampli-fiers must be installed in the same enclosure or within the same room in conduit. 14-18 AWG, twisted-pair, unshielded.Product Weight: 7.2 lb (3.27 kg).Standards and CodesThe DS-DB Digital Series Distribution Board complies with the following standards:•NFP A 72 2007 National Fire Alarm Code •Underwriter Laboratories Standard UL 864•Underwriter Laboratories of Canada (ULC) ULC-S527-99Standard of Control Units for Fire Alarm Systems•Part 15 Class A conducted and radiated emissions as required by the FCC.•BC 2012, BC 2009, BC 2006, BC 2003, BC 2000(Seismic).•CBC 2007 (Seismic)Listings and ApprovalsThese listings and approvals apply to the DS-DB Digital Dis-tribution Board. In some cases, certain modules may not be listed by certain agencies, or listing may be in process. Con-sult factory for latest listing status.•UL Listed: S635.•ULC Listed: S635.•CSFM: 7165-0028:0243 (NFS2-640/NFS-320), 7165-0028:0224 (NFS2-3030).•Fire Dept. of New Y ork: COA#6121 (NFS2-640/NFS-320),COA#6114 (NFS2-3030).Product Line InformationDS-DB : Digital Series Distribution Board.DS-AMP: 120 VAC Digital Audio Amplifier (50/60 Hz), 125W (25V RMS ), 100W (70V RMS ). Ships with chassis. See DN-60663.DS-AMPE: 220-240 VAC Digital Audio Amplifier (50/60 Hz),125W (25V RMS ), 100W (70V RMS ). 70V RMS configuration requires step-up transformer. Ships with chassis. See DN-60663.DS-BDA: Backup amplifier, provides an economical means of backup for DS-AMP amplifiers in a one-to-one primary/backup configuration. Can also provide a second audio chan-nel for a DS-AMP when programmed as a primary amplifier.25V RMS or 70V RMS . 70V RMS configuration requires step-up transformer. See DN-60663.DS-XF70V: Step-up transformer, required for 70VRMS con-figuration of DS-AMP/E and DS-BDA. Ordered separately.See DN-60663.DS-FM: Fiber option module for multi-mode fiber. Converts a wire DAP (digital audio port) to a multi-mode fiber port. See DN-60633.DS-SFM: Fiber option module for single-mode fiber. Con-verts a wire DAP (digital audio port) to a single-mode fiber port. See DN-60633.DS-RFM: Fiber option module for multi-mode fiber. Used exclusively for compatibility with multi-mode fiber DVC or DAA. See DN-60633.。
ES1B中文资料(Diodes)中文数据手册「EasyDatasheet - 矽搜」
公司产品是专门未经授权未经生命支持设备或系统的关键组件公司的
首席执行官的书面批准 .如本文所用:
A.生命支持设备或系统的设备或系统,其中:
生命保障
1.旨在植入到体内,或 2.支持或维持生命,其未履行正确使用时按照所提供的使用说明
机械数据
• Case: SMA • 外壳材料:模压塑料. UL可燃性分类
等级94V-0 • 湿度敏感度:每J-STD-020 1级 • Terminals: Lead Free Plating (Matte Tin Finish) Solderable per
MIL-STD-202,方法208 • 极性:负极频带或阴极诺奇 • Weight: 0.064 grams (approximate)
公司不保证或任何接受任何通过非授权渠道购买的任何产品承担任何责任 . 如果客户购买或使用Diodes公司产品的任何意外或未经授权的应用程序,客户应赔偿并Diodes公司及其代表的所有索赔,损害赔偿,费用和律师直接或间接引起 的,费用无害,人身伤害的任何索赔或与此类意外或未经授权的应用程序死亡.
本文描述的产品可能受一个或多个美国,国际或外国专利正在申请中.产品名称和标记.本文中也可以包含在一个或多个美国,国际或涉外商标.
A 2.29 2.92 B 4.00 4.60 C 1.27 1.63 D 0.15 0.31 E 4.80 5.59 G 0.05 0.20 H 0.76 1.52 J 2.01 2.30
在毫米所有尺寸
芯片中文手册,看全文,戳
建议焊盘布局
C
X
Y
G
Z
ES1A - ES1G
尺寸值(单位 mm)
Z
6.5
G
1.5
SN54LS685FK中文资料
PACKAGING INFORMATIONOrderable Device Status(1)PackageType PackageDrawingPins PackageQtyEco Plan(2)Lead/Ball Finish MSL Peak Temp(3)84151012A ACTIVE LCCC FK201TBD Call TI Level-NC-NC-NC 8415101RA ACTIVE CDIP J201TBD Call TI Level-NC-NC-NC 8415101RA ACTIVE CDIP J201TBD Call TI Level-NC-NC-NC 8415101SA ACTIVE CFP W201TBD Call TI Level-NC-NC-NC 8415101SA ACTIVE CFP W201TBD Call TI Level-NC-NC-NC 84152012A ACTIVE LCCC FK201TBD Call TI Level-NC-NC-NC 8415201RA ACTIVE CDIP J201TBD Call TI Level-NC-NC-NC 8415201SA ACTIVE CFP W201TBD Call TI Level-NC-NC-NC 84153012A ACTIVE LCCC FK201TBD Call TI Level-NC-NC-NC 8415301RA ACTIVE CDIP J201TBD Call TI Level-NC-NC-NC 8415301SA ACTIVE CFP W201TBD Call TI Level-NC-NC-NC SN54LS682J ACTIVE CDIP J201TBD Call TI Level-NC-NC-NC SN54LS682J ACTIVE CDIP J201TBD Call TI Level-NC-NC-NC SN54LS684J ACTIVE CDIP J201TBD Call TI Level-NC-NC-NC SN54LS688J ACTIVE CDIP J201TBD Call TI Level-NC-NC-NC SN74LS682DW ACTIVE SOIC DW2025Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS682DW ACTIVE SOIC DW2025Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS682DWE4ACTIVE SOIC DW2025Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS682DWE4ACTIVE SOIC DW2025Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS682DWR ACTIVE SOIC DW202000Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS682DWR ACTIVE SOIC DW202000Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS682DWRE4ACTIVE SOIC DW202000Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS682DWRE4ACTIVE SOIC DW202000Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS682N ACTIVE PDIP N2020Pb-Free(RoHS)CU NIPDAU Level-NC-NC-NCSN74LS682N ACTIVE PDIP N2020Pb-Free(RoHS)CU NIPDAU Level-NC-NC-NCSN74LS682NE4ACTIVE PDIP N2020Pb-Free(RoHS)CU NIPDAU Level-NC-NC-NCSN74LS682NE4ACTIVE PDIP N2020Pb-Free(RoHS)CU NIPDAU Level-NC-NC-NCSN74LS682NSR ACTIVE SO NS202000Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS682NSR ACTIVE SO NS202000Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS682NSRE4ACTIVE SO NS202000Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS682NSRE4ACTIVE SO NS202000Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMOrderable Device Status(1)PackageType PackageDrawingPins PackageQtyEco Plan(2)Lead/Ball Finish MSL Peak Temp(3)SN74LS684DW ACTIVE SOIC DW2025Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS684DWE4ACTIVE SOIC DW2025Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS684DWR ACTIVE SOIC DW202000Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS684DWRE4ACTIVE SOIC DW202000Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS684N ACTIVE PDIP N2020Pb-Free(RoHS)CU NIPDAU Level-NC-NC-NCSN74LS684NSR ACTIVE SO NS202000Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS684NSRE4ACTIVE SO NS202000Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIM SN74LS686DW OBSOLETE SOIC DW24TBD Call TI Call TISN74LS686NT OBSOLETE PDIP NT24TBD Call TI Call TISN74LS687NT OBSOLETE PDIP NT24TBD Call TI Call TISN74LS687NT OBSOLETE PDIP NT24TBD Call TI Call TISN74LS688DW ACTIVE SOIC DW2025Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS688DWE4ACTIVE SOIC DW2025Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS688DWR ACTIVE SOIC DW202000Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS688DWRE4ACTIVE SOIC DW202000Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS688N ACTIVE PDIP N2020Pb-Free(RoHS)CU NIPDAU Level-NC-NC-NC SN74LS688N3OBSOLETE PDIP N20TBD Call TI Call TISN74LS688NE4ACTIVE PDIP N2020Pb-Free(RoHS)CU NIPDAU Level-NC-NC-NCSN74LS688NSR ACTIVE SO NS202000Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIMSN74LS688NSRE4ACTIVE SO NS202000Green(RoHS&no Sb/Br)CU NIPDAU Level-1-260C-UNLIM SNJ54LS682FK ACTIVE LCCC FK201TBD Call TI Level-NC-NC-NC SNJ54LS682FK ACTIVE LCCC FK201TBD Call TI Level-NC-NC-NC SNJ54LS682J ACTIVE CDIP J201TBD Call TI Level-NC-NC-NC SNJ54LS682J ACTIVE CDIP J201TBD Call TI Level-NC-NC-NC SNJ54LS682W ACTIVE CFP W201TBD Call TI Level-NC-NC-NC SNJ54LS682W ACTIVE CFP W201TBD Call TI Level-NC-NC-NC SNJ54LS684FK ACTIVE LCCC FK201TBD Call TI Level-NC-NC-NC SNJ54LS684J ACTIVE CDIP J201TBD Call TI Level-NC-NC-NC SNJ54LS684W ACTIVE CFP W201TBD Call TI Level-NC-NC-NC SNJ54LS688FK ACTIVE LCCC FK201TBD Call TI Level-NC-NC-NC SNJ54LS688J ACTIVE CDIP J201TBD Call TI Level-NC-NC-NC SNJ54LS688W ACTIVE CFP W201TBD Call TI Level-NC-NC-NC(1)The marketing status values are defined as follows:ACTIVE:Product device recommended for new designs.LIFEBUY:TI has announced that the device will be discontinued,and a lifetime-buy period is in effect.NRND:Not recommended for new designs.Device is in production to support existing customers,but TI does not recommend using this part in a new design.PREVIEW:Device has been announced but is not in production.Samples may or may not be available.OBSOLETE:TI has discontinued the production of the device.(2)Eco Plan-The planned eco-friendly classification:Pb-Free(RoHS)or Green(RoHS&no Sb/Br)-please check /productcontent for the latest availability information and additional product content details.TBD:The Pb-Free/Green conversion plan has not been defined.Pb-Free(RoHS):TI's terms"Lead-Free"or"Pb-Free"mean semiconductor products that are compatible with the current RoHS requirements for all6substances,including the requirement that lead not exceed0.1%by weight in homogeneous materials.Where designed to be soldered at high temperatures,TI Pb-Free products are suitable for use in specified lead-free processes.Green(RoHS&no Sb/Br):TI defines"Green"to mean Pb-Free(RoHS compatible),and free of Bromine(Br)and Antimony(Sb)based flame retardants(Br or Sb do not exceed0.1%by weight in homogeneous material)(3)MSL,Peak Temp.--The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications,and peak solder temperature.Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided.TI bases its knowledge and belief on information provided by third parties,and makes no representation or warranty as to the accuracy of such information.Efforts are underway to better integrate information from third parties.TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.TI and TI suppliers consider certain information to be proprietary,and thus CAS numbers and other limited information may not be available for release.In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s)at issue in this document sold by TI to Customer on an annual basis.元器件交易网元器件交易网IMPORTANT NOTICETexas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. T esting and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed.TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. T o minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards.TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI.Reproduction of information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation.Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions:Products ApplicationsAmplifiers Audio /audioData Converters Automotive /automotiveDSP Broadband /broadbandInterface Digital Control /digitalcontrolLogic Military /militaryPower Mgmt Optical Networking /opticalnetwork Microcontrollers Security /securityTelephony /telephonyVideo & Imaging /videoWireless /wirelessMailing Address:Texas InstrumentsPost Office Box 655303 Dallas, Texas 75265Copyright 2005, Texas Instruments Incorporated。
DA-685系列产品配件兼容性指南说明书
DA-685 SeriesComponent Compatibility GuideA list of peripheral components suitable for use with the DA-685 series of computers2016/07/05 Version 2.0Copyright Notice©2016 Moxa Inc.All rights reserved.TrademarksThe MOXA logo is a registered trademark of Moxa Inc.All other trademarks or registered marks in this manual belong to their respective manufacturers.DisclaimerInformation in this document is subject to change without notice and does not represent a commitment on the part of Moxa.Moxa provides this document as is, without warranty of any kind, either expressed or implied, including, but not limited to, its particular purpose. Moxa reserves the right to make improvements and/or changes to this manual, or to the products and/or the programs described in this manual, at any time.Information provided in this manual is intended to be accurate and reliable. However, Moxa assumes no responsibility for its use, or for any infringements on the rights of third parties that may result from its use.This document might contain unintentional technical or typographical errors. Changes are periodically made to the information herein to correct such errors, and these changes are incorporated into new editions of the publication.Technical Support Contact Information/supportMoxa AmericasToll-free: 1-888-669-2872 Tel: +1-714-528-6777 Fax: +1-714-528-6778 Moxa China (Shanghai office) Toll-free: 800-820-5036Tel: +86-21-5258-9955Fax: +86-21-5258-5505Moxa EuropeTel: +49-89-3 70 03 99-0 Fax: +49-89-3 70 03 99-99 Moxa Asia-Pacific Tel: +886-2-8919-1230 Fax: +886-2-8919-1231Moxa IndiaTel: +91-80-4172-9088 Fax: +91-80-4132-10451. IntroductionThis document lists hardware components that are proven to provide the performance listed in the specification when used with the Moxa DA-685 series of embedded computers, or computers that share basic design features with the DA-685 series. Moxa computers come with multiple peripheral options and are engineered to work with components having different hardware specifications. This flexibility could sometimes lead to compatibility issues. When used with the DA-685 series of embedded computers, peripherals from one manufacturer may not work as well as the ones made by another manufacturer. Moxa provides this list of DA-685 series-compatible components, so that users can be certain of a reliable performance from the DA-685 series, when used with the components listed in this document.2. Testing MethodsTo validate that a component meets the Moxa standards for quality and performance, the following five key compatibility tests are run:•Ambient temperature burn-in•Low temperature hard start•Heat/humidity burn-in•Cyclic high-low temperature burn-in•Vibration testAmbient Temperature Burn-InThe component is mounted on to a DA-685 computer and put through a series of stress tests at an ambient temperature of around 25˚C, for a specified period of time. The duration of the test is determined based on the class of peripherals being tested.Low Temperature Hard StartThe component is mounted on to an unpowered DA-685 computer and then the system is booted up at an extremely low temperature. The designated low temperature value depends on the computer model being tested.Heat/Humidity Burn-InThe component is mounted on to a DA-685 computer, placed in a temperature- andhumidity-controlled enclosure, and then put through the burn-in test for a specified period of time. The temperature, humidity, and time targets vary depending on the specification of the computer model used in the test.Cyclic High-Low Temperature Burn-InThe component is mounted on to a DA-685 computer, placed in a temperature controlled enclosure, and then put through the burn-in test wherein the temperature is cyclically varied from very high to very low and back again, over a specified period of time. The target temperature range and the duration of the test can vary depending on the specification of the computer model used in the test.Vibration TestThe component is mounted on to a DA-685 computer that is bound inside an electromagnetic vibrator, and then put through random vibration tests along three orthogonal axes: longitudinal, transverse, and vertical. The vibration tests are compliant with the EN50155/IEC61373 vibration standards.3. Storage EnduranceStorage media, such as SSDs, CF cards, SD cards, Disk on Module, and Cfast, are composed of different electrical components. The main electrical components in these storage media, the NAND-flash memory and NAND-flash controller, impact the storage endurance and lifespan of the storage media.NAND-Flash Memory EnduranceNAND-flash memories have a limit on the number of times they can be programmed and erased (P/E). The P/E cycle as well as the erase count of a NAND-flash memory can be used to determine this limit. For example, an SLC (single-level cell) flash memory has a 60,000 P/E cycle, an MLC (multi-level cell) flash memory has a 3,000 P/E cycle, and TLC NAND flash memories have P/E cycle values up to 1,000. Each flash memory type has a different endurance level, which is why the storage lifespan is based on the flash memory type. Storage that uses SLC type flash memory could have the best endurance level compared with the MLC type storage. SLC storage usually comes with a 5-year OEM warranty (the actual warranty period depends on the original manufacturer). MLC storage only comes with a 1- to 3-year warranty. The major differences between SLC and MLC are: (a) The SLC NAND flash has a lifespan that is around 20 times that of an MLC, and (b) The price can differ by a factor of 4 to 5. The SLC type of storage is recommended for systems that are expected to have high reliability, and for applications that need to frequently write data to a storage medium.Terabytes Written (TBW)TBW is the unit used to evaluate SSD endurance. In actual applications, storage is used for routine operations and data access. Therefore the physical P/E cycle is not appropriate for describing thetotal rewritable data capacity result. For these reasons, Joint Electron Device Engineering Council (JEDEC) has defined a standard for SSD endurance evaluation called JESD218, which uses TBW to measure the endurance of the storage memory. By referring to this TBW value, users can easily estimate the storage specification and select a suitable storage for real-life use cases. For example, when routine operations need a maximum of 20 GB and the expected storage lifespan is 3 years, the total rewritable data demand would be 21.9 TBW (20 GB x 365 x 3). In this case, a storage that has more than 21.9 TBW will meet the requirement. We recommend selecting a storage media with a TBW that is greater than the calculated value.4. Declaration for Liability ExclusionThe specifications, warranty terms, and liability of items listed in this guide are the sole responsibility of the original manufacturers. Moxa does not take any responsibility in this regard. Please visit the manufacturers’ official websites for up-to-date product information before purchasing the components.5. Compatible ComponentsPeripheral components that have been tested and found suitable for use with the DA-685 series of computers are listed in this section. The following table lists the Test Codes and their descriptions:Test Code DescriptionA The component has passed the ambient temperature verification testB The component has passed the low temperature verification testC The component has passed the heat/humidity verification testD The component has passed the cyclic high-low temperature verification testE The component has not been tested, but is similar to another component that has been tested in terms of its material and design.F The component has passed the vibration verification testDRAMVendor MemorySize Moxa’s PN Vendor’s PN Interface Chip Brand Speed Test Codes DSL 1 GB N/A D2SM64162XH30ABIS DDR2 Micron 667 MHz B, C, D DSL 1 GB 1352110012030 D2SP64162XH30AAIS DDR2 ProMOS 667 MHz B, C, D DSL 2 GB 1352110022070 D2SP28082XH30ABIS DDR2 ProMOS 667 MHz B, C, D DSL 2 GB N/A D2SM28082XH30ABIS DDR2Micron 667 MHz B, C, D DSL 2 GB 1352110022080 D2SH28082XH30AB DDR2Hynix 667 MHz B, C, D DSL 4 GB 1352110042040 D2SM56082XH30AB DDR2Micron 667 MHz B, C, D InnoDisk 2 GB N/A M2SJ-2GPF2W05-B DDR2ProMOS 667 MHz B, C Transcend 1 GB N/A TS128MSQ64V8U DDR2Samsung 800 MHz E Transcend 2 GB N/A TS256MSQ64V8U DDR2Samsung 800 MHz A Transcend 2 GB N/A TS256MSQ64V6U-I DDR2Hynix 667 MHz B, C, D Unigen 2 GB N/A UG25T6400M8SU-8CP-000-00 DDR2Hynix 800 MHz B, C, DDOMVendor StorageSize Moxa’s PN Vendor’s PNFlashMemoryBrandFlashMemorySpecController Firmware Warranty WarrantyExclusionTestCodesInnoDisK 2 GB 1352020022080 DE4H-02GD31W1DB-A31 N/A SLC N/A N/A 5 years Endurance >60,000 B, C Memoright 1 GB N/A MRDEM2B001GB7P1IA0 Samsung SLC SM2232 K0407 5 years N/A E Memoright 2 GB N/A MRDEM2B002GB8P1IA0 Samsung SLC SM2232 K1124 5 years N/A B, C, D Memoright 8 GB N/A MRDEM2B008GN2P1IA0 Micron SLC SM2232 K0407 5 years N/A B, C, D Silicon Power 8 GB N/A SP008GBIFM44FOV10-MA Samsung SLC N/A N/A 3 years N/A B, C, D Transcend 1 GB N/A TS1GDOM44V-S Samsung SLC SM223 AC N/A 2 years N/A E Transcend 2 GB N/A TS2GPTM510-44V Samsung SLC SM2231 AD N/A 2 years N/A E Transcend 4 GB N/A TS4GPTM510-44V Samsung SLC SM2231 AD N/A 2 years N/A E Transcend 8 GB N/A TS8GPTM510-44V Samsung SLC SM2231 AD N/A 2 years N/A ACFVendorStorage SizeMoxa’s PNVendor’s PNFlash MemoryBrandFlash Memory SpecControllerFirmwareWarrantyWarranty ExclusionTest CodeApacer 4 GB N/A AP-CF004GL9FS-NR N/A MLC N/A N/A 2 years Endurance > 3,000 E Apacer 8 GB N/A AP-CF008GL9FS-NR N/A MLC N/A N/A 2 years Endurance > 3,000 E Apacer 8 GB N/A AP-CF008GLAFS-NR N/A MLC N/A N/A 2 years Endurance > 3,000 E Apacer 16 GB N/A AP-CF016GLAFS-NR N/A MLC N/A N/A 2 years Endurance > 3,000 E Apacer 16 GB N/A AP-CF016GL9FS-NR N/A MLCN/A N/A 2 years Endurance > 3,000 E Apacer 32 GB N/A AP-CF032GL9FS-NR N/A MLC N/A N/A 2 years Endurance > 3,000 A Apacer 32 GB N/A AP-CF032GLAFS-NR N/A MLC N/A N/A 2 years Endurance > 3,000A Transcend 128 MB N/A TS128MCF200I Samsung MLC SM2232AD N/A 2 years N/AE Transcend 256 MB N/A TS256MCF200I Samsung MLC SM2232AD N/A 2 years N/A E Transcend 512 MB N/A TS512MCF200I Samsung MLC SM2232AD N/A 2 years N/A E Transcend 1 GB N/A TS1GCF133 SanDisk/ MicronMLC SM2232AD N/A 2 years N/A E Transcend 1 GB N/A TS1GCF200I Samsung MLC SM2232AD N/A 2 years N/A E Transcend 2 GB N/A TS2GCF133 SanDisk/ MicronMLC SM2232AD N/A 2 years N/A E Transcend 2 GB N/A TS2GCF200I Samsung MLC SM2232AD N/A 2 years N/A E Transcend 4 GB N/A TS4GCF133 SanDisk/ MicronMLC SM2232AD N/A 2 years N/A E Transcend 4 GB N/A TS4GCF200I Samsung MLCSM2232AD N/A 2 years N/A A Transcend 8 GB N/A TS8GCF400 SanDisk/ Micron MLC SM2236AC N/A 2 years N/A E Transcend 8 GB N/A TS8GCF133 SanDisk/ MicronMLC SM2232AD N/A 2 years N/A E Transcend 8 GB N/A TS8GCF200I Samsung MLCSM2232AD N/A 2 years N/A E Transcend 16 GB N/A TS16GCF1000 SanDisk/ Micron MLC SM2232ENAC N/A 2 years N/A E Transcend 16 GB N/A TS16GCF400 SanDisk/ Micron MLC SM2236AC N/A 2 years N/A E Transcend 16 GB N/A TS16GCF133 SanDisk/ MicronMLC SM2232AD N/A 2 years N/A E Transcend 16 GB N/A TS16GCF200I Samsung MLCSM2232AD N/A 2 years N/A E Transcend 32 GB N/A TS32GCF1000 SanDisk/ Micron MLC SM2236AC N/A 2 years N/A A Transcend 32 GB N/A TS32GCF400 SanDisk/ Micron MLC SM2236AC N/A 2 years N/A A Transcend 32 GB N/A TS32GCF133 SanDisk/ MicronMLC SM2232AD N/A 2 years N/A E Transcend32 GBN/ATS32GCF200ISamsungMLCSM2232ADN/A2 yearsN/AASSDVendorStorage SizeMoxa’s PNVendor’s PNFlash MemoryBrandFlash Memory SpecControllerFirmwareWarrantyWarranty ExclusionTest CodesApacer 64 GB N/A AP64GAS510SB N/A MLC N/A N/A 2 years Endurance > 3,000 A InnoDisk 32 GB N/A DGS25-32GD67SC1QCP Samsung MLC N/A N/A 2 years Endurance > 3,000 B, C, D InnoDisk 32 GB N/A DGS25-32GD81SC1QCP Toshiba MLC N/A N/A 2 yearsEndurance > 3,000B, C Memoright 32 GB N/A MRSAJ6C032GC125C00 Micron MLC JMF612 MRV1.1.5 3 years Endurance > 3,000 B, C, D Memoright 32 GB N/A MRSAJ9A032GTT25C00Toshiba MLC JMF667 MRV1.71b 3 years Endurance > 3,000B, C, D Transcend 16 GB N/A TS16GSSD500 Samsung SLC JM616 120820 2 years N/A E Transcend 32 GB N/A TS32GSSD500 Samsung SLC JM616 120820 2 years N/A E Transcend 64 GB N/A TS64GSSD320 SanDisk/ MicronMLC SF2281 N/A 2 years N/A E Transcend 64 GB N/A TS64GSSD500 Samsung SLC JM616 120820 2 years N/A A Transcend 128 GB N/A TS128GSSD320 SanDisk/ Micron MLC SF2281 N/A 2 years N/A E Transcend256 GBN/ATS256GSSD320SanDisk/ MicronMLCSF2281N/A2 yearsN/AAHDDVendor StorageSize Moxa’s PN Vendor’s PN Controller Firmware Test Code HGST 500 GB N/A HTS725050A7E630 / 0J38075 N/A N/A A HGST 1 TB N/A HCC541010A9E680 N/A N/A A HGST 1 TB N/A HTS541010A9E680 N/A N/A A HGST 1 TB N/A HTS721010A9E630 / 0J22423 N/A N/A A HGST 1 TB N/A HTS541010A9E650 N/A N/A A Samsung 2 TB N/A ST2000LM003 N/A N/A A WD 750 GB N/A WD7500BPKT N/A N/A A WD 1 TB N/A WD10JUCT N/A N/A A WD 1 TB N/A WD10JPVT N/A N/A A WD 1 TB N/A WD10SPCX N/A N/A A。
EVDO Rev.A USB Modem CDU-685A 使用说明书
Get Started EVDO Rev. A USB ModemCDU-685ATable of ContentsHow to Use This GuideSection 1: Introducing the EVDO Rev.A USB Modem1A. Introducing the Cox EVDO Rev.A-System Requirements-Package Contents-Care and MaintenanceSection 2: Installing and Using the USB Modem2A. Installing the Software and Drivers2B. Using Your USB Modem-Activating Your USB Modem-Viewing the User Guide-Removing the USB Modem-TroubleshootingSection 3: Technical Specifications, Regulatory and Safety Information, and Warranty 3A. Technical Specifications-Radio Frequency and Electrical Specifications-RF Frequencies-Software Specifications-Environmental Specifications-Mechanical Specifications3B. Regulatory Information-Caution-WARNING (EMI) – United States FCC Information-Body worn operation3C. Important Safety Information-Important Notice-Safety and Hazards3D. Warranty-Manufacturer's Limited One-Year WarrantyHow to Use This GuideThe advantages of Cox are as clear as each wireless connection you make. With Cox service, we give you what you really want from a wireless service provider—clear connections, easy-to-understand service plans, and self-servicing options for managing your account. All this is designed to make your life easier and worry-free.We know you’re eager to start using your USB Modem CDU-685A right away, and the sections of this guide are designed to help you do just that.The first section gives an overview of the USB Modem CDU-685A package contents.The second section guides you through the steps required to install your USB Modem CDU-685A and the Windows drivers and software, describes how to start the software once it is installed, and explains how to use the Y-extension cable with your device.The third section lists the technical specifications, regulatory and important safety information, and warranty information for your USB Modem CDU-685A.Getting More Information About Your Device and ServiceThis guide describes how to install and start the software. To learn how to use all the features of your USB Modem CDU-685A and software, consult the user guide or online help.Section 1 : Introducing the EVDO Rev.A USBModemSection 1A : Introducing the Cox EVDO Rev.A USB ModemThis section introduces your USB Modem CDU-685A, and describes what is included with your device.The USB Modem CDU-685A is a wireless USB modem.Using this device, and subject to network availability, you can:•Easily activate your account•Connect to the Internet and to VPN and corporate networks•Send and receive large email messages•Download media content (music, videos and real-time and streaming media)•Play games onlineSystem RequirementsThis Cox Mobile Broadband USB modem is supported on:•Windows Vista.•Windows XP with Service Pack 2 or later.•Windows 2000 with Service Pack 4 or later.•Windows 7To install and run the USB modem and the accompanying Cox Connection Manager SM software, you will need:a free USB slot.• a minimum of 256 MB of memory using Windows 2000 and Windows XP.• a minimum of 1 GB of memory using Windows Vista.• a minimum of 70 MB of free space on your hard drive.• a minimum processor speed of 300 MHz for Windows 2000 and Windows XP.• a minimum processor speed of 800 MHz for Windows Vista.*Note : You can connect your device to any computer (desktop or laptop) with a USB slot.Package ContentsUSB Modem CDU-685A package contains the following components:•Cox EVDO Rev.A USB Modem CDU-685A•Get Started guide•Installation CDCare and MaintenanceAs with any electronic device, USB modem must be handled with care to ensure reliable operation. Follow these guidelines in using and storing the USB modem:•The USB modem should fit easily into an available USB slot. Forcing the device into a slot may damage the connector pins.•Protect your USB modem from excessive moisture and heat, and from prolonged exposure to the sun.•When it is not connected to your computer, store your USB modem in the pouch that came with the modem to avoid dust.•Remove your USB modem before storing or transporting your computer.•When inserting or removing your USB modem, always grip from the sides rather than the end, as this prevents damage to the USB modem.•Do not use your USB modem while driving a vehicle, as it may distract you from properly operating the vehicle.•Dispose of your USB modem in accordance with EPA guidelines. For more information, visit /epawaste/partnerships/plugin/cellphone/index.htm.Section 2 : Installing and Using the USB ModemSection 2A : Installing the SoftwareInstalling the Software and Drivers1.Insert the installation CD into your CD-ROM drive. The CD should launch automatically. Click Setup tocontinue. (If autoplay is disabled, navigate to your CD-ROM drive in Explorer and click setup.exe.)2.In the “Welcome to the InstallShield Wizard” installation window, click Next.3.Read the License Agreement and select “I accept the terms in the License Agreement”to agree to theterms. Click Next.4.Select a skin (“New”or “Classic”) and click Next.5. In the “Destination Folder” window, click Next to accept the default installation folder (recommended); or click Change, specify a different installation folder, and then click Next to continue.6. Click Install to begin installation.7. When the “InstallShield Wizard Completed” window appears, click Finish.8. If a message that you must restart your computer is displayed, click Yes to restart your computer. Wait until your computer restarts.9. Proceed to Activating Your USB Modem.Section 2B : Using Your USB ModemActivating Your USB ModemIf your USB modem has not been preactivated or you have not activated it at the time of purchase, you must activate your account and configure the USB modem to use your account. (Normally, your device will automatically complete the activation process the first time you use it.)1.Gripping both sides of the USB modem, insert it into your computer’s USB port. Windows detectsthe USB modem and installs the drivers for it. This may take a few minutes. Once completed, thesystem tray may display “Your devices are ready to use” or “Your new hardware is installed andready to use.”unch Connection Manager by double-clicking the program’s icon.3.Hands Free activation starts automatically and will be displayed on the Cox. After the activationsuccessfully completes, it will automatically connect and welcome you to the Cox Network.4.If activation was not successful, a message window is displayed. For instructions on activating yourUSB modem, see the user guide (see “Viewing the User Guide”). Use the spaces below to writedown important information related to the activation process and your account.ESN/MEID______________________________________Activation code__________________________________Cox Phone number____________________________MSID__________________________________________Account password_______________________________Cox User Name________________________________Viewing the User GuideThe user guide provides detailed information on the Cox Connection Manager software.On your computer, select Start > All Programs > Cox > Connection Manager > Users Guide.On your computer, select Start > My Computer. Right click on CD/DVD RW Drive and select EXPLORE > UserGuide.Removing the USB Modem1.Disconnect from the Cox Connection Manager software if it is running.2.Remove the USB modem from your computer’s USB slot by gripping both sides of the USB modemand pulling straight out.Troubleshooting1. For a more complete listing of errors and possible solutions, please see the user guide or online Help. You may also call Cox Customer Service.2. Ensure that the Connection Manager software has been successfully installed on your computer.3. Ensure that your USB modem has been activated.4. Ensure that the USB modem is fully plugged into the USB slot.5. Ensure that the LED light is on; otherwise connect and then reconnect the USB modem.Section 3 :TechnicalSpecifications, Regulatory and SafetyInformation, and WarrantySection 3A : Technical SpecificationsRadio Frequency and Electrical SpecificationsFrequencies CDMA 800/AWS/1900 MHz Interface Type High-Speed USB 2.0 compliant Common air interface CDMAAntenna Diversity Support Receive DiversityDC input operating voltage +5VDC from USB host port Maximum current @+5VDC Under 500mARF FrequenciesBC0TX frequency: 824MHz – 849MHzRX frequency: 869MHz – 894MHzBC1TX frequency: 1850MHz – 1910MHzRX frequency: 1930MHz – 1990MHzAWSTX frequency: 1710MHz – 1755MHzRX frequency: 2110MHz – 2155MHzSoftware SpecificationsOS Support Windows® 2000, XP, Vista and Windows 7Environmental SpecificationsOperating conditions -20°C ~ +55°C , 85%(at 50(°C)), relative humidity (non-condensing) Storage Temperature -35°C ~ +75°CHumidity 95%, non-condensingMechanical SpecificationsDimensions 32.1mm * 72.1mm * 11.9mmWeight Approx. 23gForm Factor USB Series “A” Type plugHousing Material CASE – PCSection 3B : Regulatory InformationThis device is compliant with Parts 15, 22, 24, and 27 of the FCC Rules. Operation of this device is subject to the following two conditions:1. This device may cause harmful interference.2. This device must accept any interference received, including interference that may cause undesirable operation. FCC ID: TARCDU-685ACAUTIONUnauthorized modifications or changes not expressly approved by manufacturer could void compliance with regulatory rules and thereby your authority to use this equipment.WARNING (EMI) – United States FCC InformationThis equipment has been tested and found to comply with the limits pursuant to Parts 15, 22, 24, and 27 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in an appropriate installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:Reorient or relocate the receiving antenna.Increase the separation between the equipment and receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.Consult the dealer or an experienced radio/TV technician for help.Body worn operationSAR compliance has been established in the laptop computer(s) with Horizontal and Vertical USB slot configurations, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics.Section 3C: Important Safety InformationImportant NoticeBecause of the nature of wireless communications, transmission and reception of data can never be guaranteed. Data may be delayed, corrupted (i.e., have errors), or be totally lost. Although significant delays or losses of data are rare when wireless devices such as the Cox EVDO Rev.A USB Modem CDU-685A are used in a normal manner with a well-constructed network, they should not be used in situations where failure to transmit or receive data could result in damage of any kind to the user or any other party, including but not limited to personal injury, death, or loss of property. Manufacturer accepts no responsibility for damages of any kind resulting from delays or errors in data transmitted or received using the Cox EVDO Rev.A USBModem CDU-685A, or for failure of Cox EVDO Rev.A USB Modem CDU-685A to transmit or receive such data.Safety and HazardsDo not operate modem in areas where blasting is in progress, where explosive atmospheres may be present, near medical equipment, life support equipment, or any equipment which may be susceptible to any form of radio interference. In such areas, the Cox EVDO Rev.A USB Modem CDU-685A must be removed from your computer. It can transmit signals that could interfere with this equipment. Do not operate the Cox EVDO Rev.A USB Modem CDU-685A in any aircraft, whether the aircraft is on the ground or in flight. In aircraft, the Cox EVDO Rev.A USB Modem CDU-685A must be removed from your computer. When operating, it can transmit signals that could interfere with various onboard systems. The driver or operator of any vehicle should not operate the Cox EVDO Rev.A USB Modem CDU-685A while in control of a vehicle. Doing so will detract from the driver or operator’s control and operation of that vehicle. In some jurisdictions, operating such communication devices while in control of a vehicle is an offense.Section 3D : WarrantyManufacturer’s Limited One-Year WarrantyThe company warrants to original retail purchaser of this device, that should product during normal consumer usage conditions, be proven defective in material or any part thereof, during normal consumer usage conditions, be defective in material or workmanship that results in product failure within the first twelve (12) month period from the date of purchase, such defects will be repaired or replaced (with new or refurbished) product at the Company’s discretion, without charge for parts and labor directly related to the defect(s). This warranty extends to consumers who purchase the product in the United States or Canada and it’s not transferable or assignable. This warranty does not apply to:(a) Product subject to abnormal use or conditions, accident, mishandling, neglect, unauthorized alteration, misuse, improper installation or repair or improper storage;(b) Products whose mechanical serial number or electronic serial number has been removed, altered, or defaced;(c) Damage from exposure to moisture, humidity, excessive temperature or extreme environment conditions;(d) Damage resulting from connection to, or use of any accessory or other product not approved or authorized by the company;(e) Defects in appearance, cosmetic, decorative or structural items such as framing and non-operative parts;(f) Product damaged from external causes such as fire, flooding, dirt, sand, weather conditions, battery leakage, blown fuse, theft or improper usage of any electrical source.The Company disclaims liability for removal or reinstallation of the product, for geographic coverage, for inadequate signal reception by the antenna or for communications range or operation of the cellular system as a whole.When sending your wireless device to authorized distributors for repair or service, please note that any personal data or software stored on the device may be inadvertently erased or altered. Therefore, we strongly recommend you make a back up copy of all data and software contained on your device before submitting it for repair or service. This includes all contact lists, downloads (i.e. third-party software applications, games and graphics) and any other data added to your device. Manufacturer is not responsible for and does not guarantee restoration of any third-party software, personal information or memory data contained in, stored on, or integrated with any wireless device, whether under warranty or not, returned to manufacturer’s authorized distributors for repair or service. To obtain repairs or replacement within the terms of this Warranty, the product should be delivered with proof of Warranty coverage (e.g. dated bill of sale), the consumer’s return address, and daytime phone number and/or fax number and complete description of the problem, transportation prepaid, to the Company at the address shown below or to the place of purchase for repair or replacement processing.The extent of the company’s liability under this warranty is limited to the repair or replacement provided above and, in no event, shall the company’s liability exceed the purchase price paid by purchaser for the product.Any implied warranties, including any implied warranty of merchant ability or fitness for a particular purpose, shall be limited to the duration of this written warranty. Any action for breach of any warranty must be brought within a period of 18 months from date of original purchase in no case shall the company be liable for a special consequential or incidental damages for breach of this or any other warranty, express or implied, whatsoever. The company shall not be liable for the delay in pending service under this warranty or loss of use during the time the product is being repaired or replaced.No person or representative is authorized to assume for the Company any liability other than expressed herein in connection with the sale of this product. Some states or provinces do not allow limitations on how long an implied warranty lasts on the exclusion or limitation of incidental or consequential damage so the above limitation or exclusions may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights, which vary from state to state or province to province.TrademarksCox and the logo are trademarks of Cox. Other marks are the property of their respective owners. Windows® is a registered trademark of Microsoft Corporation. Copyright ©2009 Cox. Cox and the logo are trademarks of Cox. Other marks are the property of their respective owners.。
主机服务器性能配置测算方法-应用服务器
主机服务器性能配置测算方法-应用服务器
设备需求主要针对JAVA服务器进行测算:服务器上运行基于J2EE的中间应用软件平台,故可以将其应用处理能力量化为JAVA处理能力性能值-SpecJbb2005,同时充分考虑系统的冗余处理能力,以及系统资源分配情况,即可估算出服务器的处理能力性能值,从而确定主机的档次
▪SpecJbb2005 =A×B/(1-C-D)
▪其中:
▪A:每秒最多要处理的业务量
▪B:每笔业务需消耗的SpecJbb2000峰值
▪C:系统的冗余处理能力
▪D:非Java应用所占用的系统资源百分比
▪对于应用支撑平台:
▪A:即为其交易峰值,为1000笔/秒 (考虑应用支撑平台的场景,在原核心交易峰值2000的基础上除以2)
▪B:根据对行业应用的理解和相关项目实施经验,每笔业务消耗200个bops
▪C:系统冗余能力为40%
▪D: 非Java应用所占用的系统资源百分比为20%
/user2/53043/archives/2011/47003.html。
comfortzone产品说明书
Features:• Adjustable Thermostat • Three Heat Settings: Energy Save Mode High (1500W) Low (750W)• Fan Only Setting• Top Mounted Control Panel • Power Indicator Light• Safety Overheat Protection • Safety Tip-Over Switch • Convenient Carry Handle •120V AC, 60Hz, 12.5A, 5,120 BTUCZ447E SeriesOscillating Compact Ceramic HeaterENERGY SAVE TECHNOLOGY ® helps save energy and reduces your heating costs.ENERGY SAVE TECHNOLOGY provides comfortable heating using 30% less energy t han a standard heater!** N ote: Compared to a 1,500 watt space heater on high heat. Patent PendingPOWER LEVEL SWITCH: This heater has 3 heat settings: ENERGY SAVE, HIGH, and LOW. Select the heat setting that best meets your heating needs. The ENERGY SAVE heat setting provides comfortable heating in most rooms, while saving you money on energy costs.IMPORTANT SAFETY FEATURESThe power indicator light, located near the control panel, lights whenever the heater or fan is turned on. The heater is equipped with an automatic overheat protection device located inside the body of the heater. If the heater grille is obstructed, or if the heater gets too hot for any reason, the automatic overheat protection device will turn the heater off. To reset the heater,LIMITED WARRANTYThis unit is guaranteed to the original retail purchaser against defects in quality or workmanship for aperiod of one year from the date of original purchase. If this unit fails because of a manufacturing defecwithin 30 days of purchase, return the unit, with your receipt, to the retailer. After 30 days, but within the warranty period, if the unit was purchased within the continental United States, return it, freight prepaid, to World and Main for repair or replacement. If the unit was purchased outside the continental United States, return the unit to the place of purchase. This warranty does not cover damage caused by misuse, abuse, overheating or alteration. Repairs made by anyone other than World and Main are not covered in this warranty. World and Main will not be held liable for any losses due to neglectful operation. All implied warranties including the warranties of merchantability and of fitness of purpose, if applicable, are hereby limited in duration to the period of one year from the date of original retail purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. Incidental or consequential damages arising from a breach of either express or implied warranties are hereby disclaimed and excluded. Some states do not allow the exclusion of limitation of incidental or consequential damages,so this limitation or exclusion may not apply to you. Upon the expiration of this warranty all such liability will terminate. No other warranties are expressed or implied.This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. No informal dispute settlement mechanisms are available. This limited warranty is given in lieu of all other warranties.Manufactured for:World and Main (Cranbury), LLC324A Half Acre Rd.Cranbury, NJ 08512 USA800-221-6895Rev. 05/20/2022。
ESU01B双凸电线性机械解决方案系列ESU电带驱动线性机械说明书
Dual SaddleElectric Linear Actuator SolutionsBelt-Driven Linear Actuators•Superior belt profile for improved performance•Travels up to 5500 mm •••motor installedY O U R M O T O R/esu •(800) 624-85112ESU01BMajor Benefits• High capacity rail bearing provides superior moment and load capability • Maximum travel up to 5500 mm• Maximum Speed 5000 mm/s, Acceleration 50 m/s 2• Self-lubricating linear guides provide maintenance-free operation• Superior HTD8 steel reinforced polyurethane belt for uniform load distribution, precise tooth engagement, and improved performance• Corrosion resistant steel pulleys provide high structural strength and minimal wear• Rigid construction with low backlash • High degree of repeatability • Easy access belt tensioning system• Proven band seal technology provides IP54 ingress protection • Switch ready as standard• Mid-support(s) mounting for long travels and high payloads• Integrated shaft coupling allows for a rigid connection and zero backlash • Complete solutions with motor installed by PHD using Kollmorgen ® motor or versatile mounting for multi-axis Cartesian systems• Your Motor, Your Way allows motor and controls flexibility at no additional costsuperior HTD8 steelreinforced polyurethane beltversatile saddle mounting forapplication flexibilitydust protective wiper sealmagnetically secured, stainless steel sealing band provides IP54 protectionmounting holes for flexible end mountingdrive shaft with integrated motor couplingmaintenance-free linear guidesprofile rail guide with recirculating ball bearings provide for high load rating and rigidityeasily accessible belt-tensioning systemt-slot for mid-supports mountingrigid extrusion body and JC switch ready© Copyright 2019, by PHD, Inc. All Rights Reserved. Printed in the U.S.A.P H D’s E S U b e l tc m p e t i t o r ’s b e l to solutions availableDoubles the load capacity and increases My (pitch) and Mz (yaw) moment capacities.Dual Saddle Integrated Motor & Gear Reducer Options (M Code + RW Code)Dual Saddle Option/esu • (800) 624-85113ESU01BGreen shaded areas are options. Options areincluded in ordering code.HEADESUDESUSCAPKSxx1KSx1xMxxxxRWxxxWxxxxKS1xxKSx1xBA S EM O D E L -D U A L SA D D L ET Y P E B A SE EL - S I N GS L AV E C O N F IG U R A TI O N -Q L 00O PT I O NSxxxxQL11/esu •(800) 624-85114ESU01BNOTES:1) STRONGLY RECOMMENDED: ORDERED TRAVEL = WORKING TRAVEL + SAFETY TRAVEL ON BOTH ENDS 2) REFER TO SPEED VS. THRUST CHART 3) REFER TO SPEED VS. TORQUE CHARTWEIGHT AND INERTIAL CALCULATIONS:TOTAL WEIGHT = W OT + (W LT x TRAVEL) + MOTOR MOUNT WEIGHTTOTAL MOVING WEIGHT = W OM + (W LM x TRAVEL) + EXTERNAL PAYLOAD INERTIA Reflected = J O + (J L x TRAVEL) + (J M x TOTAL MOVING WEIGHT)DYNAMIC LOADS AND MOMENTS/esu •(800) 624-85115ESU01BThis section contains information on the capabilities of the Series ESU -RT version. It is not intended to be a comprehensive selection guide. To make the selection process simple and quick, refer to PHD’s sizing software. You may request application assistance from your distributor or PHD’s Customer Service Department.T h r u s t N [l b ]Speed m/s [in/s]Speed vs ThrustLoad Fz/Fy vs. Max. Unsupported LengthESU 55ESU 56ESU 58T o r q u e N m [l b i n ]Speed m/s [in/s]Speed vs TorqueTravel mm [in]ESU 55ESU 56ESU 586000[1349]L o a d F z N [l b ]10000[2250]1000[225]100[22.5]10[2.25]1[0.225]0250[2213]200[1770]150[1328]100[885]50[442]01000[225]1[39.4]0 500 1000 1500 2000 2500[19.685] [39.370] [59.055] [78.740] [98.425]2[78.7]3[118.1]4[157.5]5[196.8]1[39.4]2[78.7]3[118.1]4[157.5]5[196.8]2000[450]3000[675]4000[890]5000[1124]CAD & Sizing AssistanceUse PHD’s free online Product Sizing and CAD Configurator at /myphdMID-SUPPORT CALCULATIONExample (Application Requirements)Actuator – ESUS size 58 Load Fz – 1000 N [225 lb]Travel – 3000 mmUse Load Fz/Fy vs Maximum Unsupported Length graph1)Find Maximum Unsupported Length from the above graph [1000 N = 1200 mm]2)Calculate Total Actuator Length (refer to Dimensions page 6 or 7)Total Travel + Dimension A = Total Actuator Length 3000 + 628.1 = 3628.1 mm3)Determine number of required mid-supports(Total Actuator Length/Maximum Unsupported Length) – 1 = Required mid-supports (3628.1 mm/1200 mm) – 1 = 2 mid-supports (round up to next whole number)PERFORMANCE CHARTS/esu •(800) 624-85116ESU01BNOTES:1)DIMENSIONS: mm2)SADDLE SHOWN IN MID POSITION3)PHD RECOMMENDS ADDING 50 mm TO THE TOTAL WORKING TRAVEL FOR OVER-TRAVEL PROTECTION (25 mm PER END)All dimensions are reference only unless specifically toleranced.CAD & Sizing AssistanceUse PHD’s free online Product Sizing and CAD Configurator at /myphd/esu •(800) 624-85117ESU01BNOTES:1)DIMENSIONS: mm2)SADDLES SHOWN IN MID POSITION3)PHD RECOMMENDS ADDING 50 mm TO THE TOTAL WORKING TRAVEL FOR OVER-TRAVEL PROTECTION (25 mm PER END)4)MINIMUM SADDLE TO SADDLE DISTANCE SHOWNIF ADDITIONAL DISTANCE BETWEEN SADDLES IS REQUIRED, ADD APPROPRIATE LENGTH TO TOTAL TRAVEL IN 50 mm INCREMENTS EXAMPLES:SIZE 55 WITH 500 mm TRAVEL WITH STANDARD “DB” DISTANCE OF 250 mm ESUD55 x 500 -RTxxx (NO ADDITIONAL STROKE ADDER NEEDED)SIZE 55 WITH 500 mm TRAVEL WITH “DB” DISTANCE OF 350 mmESUD55 x 600 -RTxxx (WILL NEED ADDITIONAL 100 mm STROKE ADDER)FOR AN END RESULT OF 500 mm TRAVELAll dimensions are reference only unless specifically toleranced.CAD & Sizing AssistanceUse PHD’s free online Product Sizing and CAD Configurator at /myphdTypical Kit Contentsselected motor./esu •(800) 624-85118ESU01BAll dimensions are reference only unless specifically toleranced.NOTES:1)YOUR MOTOR,YOUR WAY MOTOR MOUNTS -QL11 & -QLD1 ARE PROVIDED IN KIT FORM TO ALLOW ASSEMBLY OF MOTOR TO ACTUATOR 2)KIT INCLUDES ALL PARTS REQUIRED TO ASSEMBLE AN ACTUATOR BASED ON -Wxxxx CODE SUPPLIED BY CUSTOMER 3) DIMENSIONS: mmThis option provides the ESU with an option for an undriven unit. The option is a no shaft option and does not include a housing or motor mount plate.Inline dual shaft output motor mounting is a 1:1 drive ratio with a shaft extension thru opposite side of cap. The shaft extension allows for two axis mechanical synchronization from a single motor.QL00NO SHAFT (SLAVE CONFIGURATION)MMP QLD1 OPTION ØONLY-QL00 IS A NO SHAFT OPTION AND DOES NOT INCLUDE A HOUSING OR MOTOR MOUNTING PLATE USED IN CONJUNCTION WITH THE -RT000 SLAVE UNIT CONFIGURATIONRW CODEW CODE/esu •(800) 624-85119ESU01BAll dimensions are reference only unless specifically toleranced.BOLT HOLE CIRCLE••SHAFT TYPE:FLANGE THICKNESS2 FLATS, 90Step 1 - Online Actuator Sizing • I nput your application data.• T he sizing software will tell you which actuator and motor performance parameters are needed for your application.Step 2 - Motor Selection• B ased on the performance requirements determined by online sizing,select an appropriate motor from your preferred motor manufacturer.• R eturn to the online sizing software with identified motor parameters to verify motor to application compatibility.Step 3 - Your Motor, Your Way Configurator • S elect your motor from the drop down menus or enter the necessary motor geometry.•The generated motor mount code for the compatible motor will complete the ordering data necessary to order the actuator tailored to your specific application.•3D CAD models are also available.•If a blank motor mount is desired for special motor requirements, use -W0000 to order a motor mount intended for customer modification.MOTOR GEOMETRYthey may enter necessary motor features to generate the PHD motor mount code.The tailored motor mounting components are included with the specified driver and shipped in kit form./esu •(800) 624-851110ESU01B.A factory provided gear reducer is only available when a motor is configured from PHD. The available gear reducers and associated RWxxx codes can be selected using PHD’s motor database at .Food grade lubricant replaces all standard lubricants.RWxxxY5GEAR REDUCERFOOD GRADENOTES:1)SIZE DEPENDS ON MOTOR USED, SEE CAD CONFIGURATOR MODEL FOR ACTUAL SIZE 2)QL11 AND QLD1 ARE TYPICALLY ORDERED WITH Wxxxx OR Mxxxx+RWxxx11Mounting with optional supports using the integrated T-slot. Recommended number of mid-support mounts can be determined by finding the maximum distance between supports based on the load per your application. See Engineering Data page, Load Fz/Fy vs. Maximum Unsupported Length graph.NOTE: PHD does not recommend only the use of mid supports for actuator mounting. Utilize end supports when applicable.Mid supports include one set of brackets.KSxxxEND/MID SUPPORTSREFER TO PAGE 6 FOR DIMENSIONAL DATA NOT SHOWNMID SUPPORT DETAIL SIZES 56 AND 58NOTES:1) DIMENSIONS: mm2) SADDLE SHOWN IN MID POSITION3) PHD RECOMMENDS ADDING 50 mm TO THE TOTAL WORKING TRAVEL FOR OVER-TRAVEL PROTECTION (25 mm PER END)4) BRACKETS AND HARDWARE BAGGED AND SHIPPED WITH UNITAll dimensions are reference only unless specifically toleranced.KSx1x includes one set of bracketsKSx2x includes two sets of brackets, etc.END/MID SUPPORT ORDERING EXAMPLE:12SWITCH BUNDLEMAGNETIC SWITCHThis switch provides the ability to identify a single position of travel. Solid-state sensing technology provides a highly reliable switch. Elliptical housing allows for easy “drop-in” installation. Includes LED indicator for convenient means of positioning. Available with PNP or NPN output. Available with cable or 8 mm threaded Quick Connect.All dimensions are reference only unless specifically toleranced.JC1SDx-5JC1SDx-K (Quick Connect)ØØThese options conveniently provide switches with additional hardware if required. Series JC1SDx-x single position switches are available as NPN or PNP . Connection method may also be specified along with quantity of switches, up to nine.13ZYX XMODULAR CARTESIAN SYSTEM EXAMPLES3- Axis Cartesian Robot, Permanent Arm TypeZ- Axis = ESCV Thruster Slide Y- Axis = ESU Linear Actuator X- Axis = ESU Linear ActuatorAdvantages - Small footprint, high accuracy, high speedX- Axis = ESU Linear ActuatorX'- Axis = ESU Linear ActuatorAdvantages - Large working area, high payload, high speed3- Axis Cartesian Robot, Retracting Arm TypeZ- Axis = ESCV Thruster Slide Y- Axis = ESL Thruster SlideX- Axis = ESU Linear ActuatorAdvantages PHD’s new Series ESU Electric Belt-Driven Linear Actuators feature a robust, enclosed design with a high capacity rail bearing system which delivers exceptional moment and load capability. The ESU linear actuator and other PHD electric and pneumatic actuatorscan be used in a variety of combinations that create a full range ofmotion for a variety of cartesian systems. Below are a few examples14Cylinders,Linear Slides,& GrippersWith Your Motor , Your Way!Series ECVA/ECVR Ball Screw ElectricCylindersYour Motor,Your Way!With PHD Plus, you can use the motor of your choice.Series ECPIP69K CylindersUSDA Certified for CIPN E W !Series EGRR Electric High Capacity GrippersYour Motor,Your Way!Series ESCV Vertical Thruster Electric SlidesSeries EGRKElectric Parallel GrippersSeries ESK/ESLElectric Thruster SlidesSeries ESU ElectricBelt-Driven Linear Actuators15Date:Distributor Name:Customer Name:Address:City:State:Zip:Contact Name /Title:Telephone:E-Mail Address:End Customer (if other than above):Location:Travel :Travel TimeOne direction:Cycles/MinutePayload :Duty Rate:Describe motion sequence:Completed By:General Description:Complete this form, save the file,and send via email to: ***************It can also be printed and faxed to260-747-6754, or callCustomer Service at 800-624-8511for assistance.Hour/Day Days/Week Weeks/Year166/19 10858。
粘性土的两种压缩试验方法
粘性土的两种压缩试验方法的比较摘要:采用不同状态的粘性土分别进行1h快速压缩试验和每级判稳压缩试验,对试验结果进行分析比较,建议根据工程需要选择不同的压缩试验方法。
关键词:1h压缩试验;每级判稳压缩试验土的压缩试验是研究土在有侧限条件下的压缩性能的一种室内试验,是土的常规试验之一。
试验时,将土样放在刚性金属盒内,通过承压活塞对土样由小到大分级加压,根据各级压应力与相应孔隙比,绘出土压缩曲线,求出压缩系数(a v)及压缩模量(Es)等。
由试验结果计算所得压缩模量是计算土体沉降和基床系数的重要指标。
在实验室里土的压缩试验一般有两种方法:1h快速压缩和每级判稳压缩:1. 1h快速压缩试验:把按照标准制备好的样品安装在固结仪上,按照加荷等级(常规压缩一般为50、100、200、400kPa)每小时加一级荷载,并记下相应的变形量,最后一级变形量测记后继续保持所加荷载,直到样品变形稳定(每小时变形量不超过0.005mm),记下稳定读数。
2. 每级判稳压缩试验:把按照标准制备好的样品安装在固结仪上,按照加荷等级(常规压缩一般为50、100、200、400kPa)按顺序加载,施加第一级荷载等样品变形稳定(每小时变形量不超过0.005mm)后才能加第二级荷载,记录每级荷载下的变形量。
对比两种方法的加荷过程,可以看出1h快速压缩试验所用的时间要明显少于每级判稳压缩试验,但是对于不同状态的土这两种方法得出的结果有一定的差异,采用某市地铁某标段的几种不同状态的比较均匀的粘性土进行这两种压缩试验,其试验结果如下:表1表2(表2中1h变形量经过末级判稳修正)由表1表2结算结果见表3:表3分别用1h快速压缩的Es和每级判稳的Es来计算土的基床系数(K=3.30*Es=A*Es)和土的沉降变形量(S=ΨPZ/ Es=B/ Es),结果见表4:表4比较分析上面的试验结果,可以得出如下结论:1. 1h快速压缩试验虽然节省了时间,但是土体最终变形量小于每级判稳压缩试验,土体越软,变形量差值越大,即土体越软,固结程度越低。
系统分析师考试大纲
系统分析师考试大纲一、考试说明1.考试目标通过本考试的合格人员应熟悉应用领域的业务,能分析用户的需求和约束条件,写出信息系统需求规格说明书,制订工程开发方案,协调信息系统开发及运行所涉及的各类人员;能指导制订企业的战略数据规划、组织开发信息系统;能评估和选用适宜的开发方法和工具;能按照标准标准编写系统分析、设计文档;能对开发过程进展质量控制及进度控制;能具体指导工程开发;具有高级工程师的实际工作能力和业务水平。
2.考试要求〔1〕掌握系统工程的根底知识;〔2〕掌握开发信息系统所需的综合技术知识〔硬件、软件、网络、数据库等〕;〔3〕熟悉企业或政府信息化建立,并掌握组织信息化战略规划的知识;〔4〕熟练掌握信息系统开发过程和方法;〔5〕熟悉信息系统开发标准;〔6〕掌握信息平安的相关知识及技术;〔7〕熟悉信息系统工程管理的知识及方法;〔8〕掌握应用数学、经济及管理的相关根底知识,熟悉有关的法律法规;〔9〕熟练阅读和正确理解相关领域的英文文献。
3.考试科目设置〔1〕信息系统综合知识,考试时间为150分钟,笔试,选择题;〔2〕系统分析设计案例,考试时间为90分钟,笔试,问答题;〔3〕系统分析设计论文,考试时间为120分钟,笔试,论文题。
二、考试范围考试科目1:信息系统综合知识1.计算机系统综合知识1.1 计算机组成及体系构造·各种计算机体系构造的特点及应用〔SMP、MPP等〕·构成计算机的各类部件的功能及其相互关系1.2 操作系统·操作系统的类型及构造·操作系统根本原理·操作系统性能优化·网络操作系统及嵌入式操作系统1.3 数据通信及计算机网络·数据通信的根本知识·开放系统互连参考模型·常用的协议标准·网络的互连及常用网络设备·计算机网络的分类及应用1.4 数据库系统·数据库管理系统的类型、构造和性能评价·常用的关系型数据库管理系统·数据仓库及数据挖掘技术·数据库工程中间件·异构及通用效劳、远程过程调用〔Remote Procedure Call〕、面向消息的中间件〔Message-Oriented Middleware〕、对象请求代理〔Object Request Brokers〕1.6 系统配置及性能评价·C/S及B/S构造、分布式系统·系统配置方法〔双份、双重、热备份、容错、集群〕·性能计算〔响应时间、吞吐量、TAT〕·性能设计〔系统调整、Amdahl解决方案、响应特性、负载均衡〕·性能指标〔SPEC-Int、SPEC-Fp、TPC、Gibson mix、响应时间〕·性能评估1.7 计算机应用·信息管理、数据处理、辅助设计、自动控制、科学计算·远程通信效劳、Web计算·多媒体压缩、编码及存储技术·人工智能、模式识别2. 信息化根底知识2.1 信息化·信息及信息化·信息化对组织的意义·现代组织对信息化的需求·组织的信息化及软件工程或系统集成工程的不同特点2.2 政府信息化及电子政务·电子政务的概念、内容和技术形式·中国政府信息化的策略和历程·电子政务建立的过程模式和技术模式2.3 企业信息化及电子商务·企业信息化的概念、目的、规划、方法·ERP的主要模块和主要算法·企业业务流程重组〔BPR〕·CRM、PDM在企业的应用·知识管理·企业门户·企业应用集成·全程供给链管理的思想·商业智能·电子商务的类型、标准2.4 信息资源管理2.5 国际和国内有关信息化的标准、法律和规定3. 软件工程3.1 软件工程根底知识·软件生存周期及其模型·软件需求分析及定义·软件设计·软件测试及审计·软件维护·软件复用·文档编制标准3.2 工程管理知识·工程方案的制订、监视、控制·工程工作量估算·范围管理·进度管理·配置管理·风险管理·资源和任务分配·工程的生命周期管理3.3 软件过程·软件过程的定义和范围·软件过程的作用·软件过程的开展·主要的软件过程及其特点·软件过程改良3.4 质量管理·质量保证方案·质量认证体系·质量管理和质量管理技术·全程质量管理4. 信息系统开发及运行信息系统根底知识·信息系统概念·信息系统的功能、类型、构造·信息系统的生命周期,各阶段的目标和主要工作内容·信息系统建立的原那么·信息系统开发方法需求分析和设计方法·分析设计图示〔DFD、ERD、UML、流程图、NS图、PAD〕·面向对象设计〔继承、抽象、代理、封装、多态〕·构造化分析设计·模块设计〔内聚、耦合〕·I/O设计〔报表设计、屏幕设计、数据项代码设计〕,人机界面设计开发环境及开发工具·集成开发环境·开发工具〔分析设计工具、编程工具、测试工具等〕·软件开发平台的比拟系统集成·控制集成、数据集成、表示集成,外部资源的使用应用系统构建·应用系统设计开发〔分析设计方法的使用、外部设计、内部设计、程序设计、测试〕·软件包的使用〔开发工具、运行管理工具、业务处理工具、ERP、群件、OA 工具〕·数据库设计和操作〔范式、SQL、数据分布〕·网络的规划及设计系统运行·系统运行管理〔计算机系统、数据库、网络〕·系统本钱管理〔用户收费、TCO〕·用户管理〔ID保险和管理〕·分布式系统管理·硬件资源管理·软件资源管理〔程序库管理、版本管理〕·数据资源管理、网络资源管理·设备和设施管理〔电源、设备管理、设施平安性管理〕·系统故障管理〔处理手续、监视、恢复过程、预防措施〕·平安性管理、性能管理·系统运行工具〔自动化操作工具、监视工具、诊断工具〕·系统转换〔转入运行阶段、运行测试、版本控制〕·系统运行效劳标准4.7 系统维护·维护的类型〔日常检查、定期维护、预防性维护、事后维护、远程维护〕·软件维护、硬件维护·维护合同5. 平安性·数据平安和保密,加密及解密机制·计算机故障诊断和防范,防治计算机病毒,防范计算机犯罪,防闯入·通信和网络平安·系统访问控制技术·完整性·私有信息保护·平安管理措施,有关的法律、法规、制度6.标准化及知识产权·标准化意识,标准化的开展,标准的生命周期·国际标准、美国标准、国家标准、行业标准、地方标准、企业标准·代码标准、文件格式标准、平安标准、软件开发标准和文档标准·标准化机构·知识产权7. 经济、管理等相关知识·企业法律制度·会计常识·财务本钱管理实务·现代企业组织构造·人力资源管理·企业文化管理·IT审计的相关常识〔审计标准、实施和审计报告〕8. 应用数学·概率统计应用·图论应用·组合分析·算法〔数值算法及非数值算法〕的选择及应用·运筹方法〔网络方案技术、线性规划、预测、决策、库存管理、模拟〕·数学建模9. 专业英语·具有高级工程师所要求的英文阅读水平·掌握本领域的英语术语考试科目2:系统分析设计案例1. 系统方案·信息系统工程的提出及选择,工程优先级确实定·基于管理层次的业务评价·分析信息系统的实施目的、功能、构架、规模、能力、维护、应用方法及故障情况等·系统开发规划·可行性研究及效益分析·系统方案的制定、评价和改良·遗留系统的评价和处理策略·新旧系统的分析和比拟·基于企业信息战略,进展技术调研和评估·制订信息系统设想〔方案〕评价标准·方案变更及控制2. 需求获取和分析·业务模型的抽取、决策及图形化和公式化·对象业务流的提取和确认·从信息系统的观点对确认内容进展整理·明确对象业务问题的分析和解决方向·业务功能的模型化·对象业务全体以及业务功能整合性方面的探讨·现有软件系统的分析·确认测试方案·主要需求分析方法论3. 系统分析·组织构造及功能分析·业务流程分析·数据汇总及数据流程分析·系统功能划分及数据资源分布·系统的故障模型和可靠性模型·系统的可靠性分析和可靠度计算·提高系统可靠性的措施·系统的故障对策和系统的备份及恢复·系统分析的实用技术·流行的系统分析方法论4. 系统设计4.1 建模技术·需求建模的步骤·用例驱动的开发方式·构造化建模技术、数据流图·面向对象建模技术·数据库建模系统设计·处理流程设计·系统人机界面设计·数据库管理系统的选择及数据库设计·系统平安性设计·网络环境下的计算机应用系统的设计·分布式应用系统的设计·多媒体应用系统的设计·系统运行环境的集成及设计·系统处理能力评估·系统测试方案以及测试的实施·系统转换方案5. 文档编制和沟通能力·信息战略文档化·信息系统设想文档化·可行性研究报告·工程开发方案·需求规格说明书·数据要求规格说明书·用户手册·操作手册·测试方案、测试分析报告·技术报告·开发进度记录·工程开发总结报告6. 系统运行和维护·软件维护的实施和管理·系统的软硬件配置管理·系统的使用效率的跟踪·根本软件和软件包的引入、应用、管理和二次开发·系统的扩大和集成·操作设计和运行管理·系统的更新及维护·长期方案和短期方案·新旧系统的转换交接·日常的故障对策及恢复·系统的日常平安管理·系统的效劳质量和运用评价7.软件过程改良·软件过程改良的管理·软件过程改良的体系设计·软件过程改良的方法·软件过程改良的工具8. 系统开发工程管理·范围管理·进度管理·本钱管理·质量管理·人力资源管理·风险管理9. 企业信息化战略及实施·信息规划及战略规划的关系·信息规划的概念、活动及角色·信息系统规划方法·企业过程再工程·CIO的概念和主要职责·管理咨询在信息化中的作用和意义·管理咨询的类型·“信息孤岛〞形成的根源及预防、应对措施·典型的信息化实施过程·知识管理的含义·知识管理对组织信息化的意义·知识管理常用的工具和手段考试科目3:系统分析设计论文1. 信息系统工程·系统方案和分析·需求工程·系统测试·系统维护·工程管理·质量保证·面向对象技术·计算机辅助软件工程·软件过程改良实践·实时系统的开发·应用系统分析及设计〔嵌入式系统、数据仓库、互联网应用等〕·软件产品线分析及设计2. 数据库及应用·数据管理·数据库分析·数据库建模·数据库管理·数据库应用·数据仓库、数据集市和数据挖掘3. 网络规划及应用4. 系统平安·网络平安·数据平安·容灾5. 新技术的应用6. 应用系统集成7. 企业信息系统·电子商务和电子政务·事务处理系统·决策支持系统8. 企业信息化的组织和实施三、题型举例〔一〕选择题需求分析是一种软件工程活动,它在系统级软件分配和软件设计间起到桥梁的作用。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Passage and maintenance Passage and maintenance in front of ESB
通道及维修
应急配电板前设有通道(板前维修)
Protection level 防护等级
Top IP22 顶部 IP22
Cable entrance 电缆入口
Bottom 底部
Handrail 扶手
RL1 switch off indicator lamp for emergency generator ACB 应急发电机主开关分闸指示灯
1 red 红色
CB1 switch on pushbutton for emergency generator ACB 应急发电机主开关合闸按扭
1 green 绿色
DESCRIPTION
名
称
QTY 数量
REMARK 附注
A1,AS1 ammeter and change-over switch, 各 1 measure each phase current of
range 0-250A, marked red line at 162.4A 电流表及转换开关,量程 0-250A,
400V 标红线
F1 KW1 M1
frequency meter, marked red line at 50HZ 频率表,50HZ 标红线
wattmeter, marked red line at 90KW 功率表,90KW 标红线
megohmmeter 兆欧表
1 45-55HZ 1 0—120KW 1 Q96- MΩ
OB1
switch off pushbutton for emergency generator ACB 应急发电机主开关分闸按扭
1 red 红色
SINGLE LINE DIAGRAM OF THE EMER. SWITCHBOARD
SDG685-641-02
PAGE 6 OF 11
GL2 switch on indicator lamp for main power supply MCCB 主电源供电开关合闸指示灯
RL3 low insulation alarm indicator lamp for AC380V net 380V 绝缘报警指示灯
red 1 红色
GL1 switch on indicator lamp for emergency generator ACB 应急发电机主开关合闸指示灯
1 green 绿色
SINGLE LINE DIAGRAM OF THE EMER. SWITCHBOARD
SDG685-641-02
TECHNICAL REQUIREMENT
技术要求
PAGE 3 OF 11
1. 应急配电板的制造应符合 IEC 标准和 CCS 规范的有关要求
The manufacture of emergency switchboard is to comply with the relating requirements of IEC standard and CCS rules. 2. 应急配电板的结构和安装
The specification and setting value of each circuit-breaker on switchboard should be selected according to the drawing, in order to offer perfect protection to electric appliance. 10. 配电板上的仪表应选用精密度等级不低于 1.5 级的产品。
EACB emergency generator ACB 应急发电机主开关
VR1 voltage adjuster 电压调整器
1 green 绿色
1 red 红色
1 blue 蓝色
1
1 Type: 型号:NSX250F/MIC5.2A
1 inside panel 装于面板内
EMER. GENERATOR CONTROL PANEL / AC380V LOAD PANEL 应急发电机控制屏/AC380V 负载屏(1/ESB)
generator 测量发电机每相电流
162.4A 标红线
V1,VS1 voltmeter and change-over switch, 各 1 measure voltage of busbar
range 0-480V,marked red line at
测量汇流排,发电机相间电压
400V 电压表及转换开关,量程 0-480V,
forwards horizon setup 前面水平
Painting 油漆
Color: international standard 7.5BG7/2 喷塑,颜色:国际标准蒙塞尔 7.5BG7/2
Nameplate 铭牌
Antiflaming material,chinese 滞燃材料,中文
External dimensions 外形尺寸(大约)
SINGLE LINE DIAGRAM OF THE EMER. SWITCHBOARD
SDG685-641-02
PAGE 5 OF 11
EMER. GENERATOR CONTROL PANEL / AC380V LOAD PANEL 应急发电机控制屏/AC380V 负载屏(1/ESB)
CODE 代号
NO. 序号
DESCRIPTION 项目
ESB-1 INPUT/OUTPUT SIGNAL FROM/TO AUTO START/STOP CONTROL BOX FOR EMERGENCY GENERATOR 输入/输出信号自/至应急发电机自启动装置
ESB-2 INPUT MSB BLACK OUT SIGNAL FROM MSB 输入主电源失电信号来自主配电板
TYPE OF SPECIFI- SETTING
CIRCUITBREAKER 断路器型号
CATION 断路器
In/Ic
VALUE 脱扣器 整定值
NSX250F/ MIC5.2A
250/250
Ir=160A tr=8s Isd=5.5Ir
tsd=0.3s
Ii=12In
ห้องสมุดไป่ตู้
NSE100N/M 25/100 Ii=6In
REMARK 断路器 附加要求
RL2 switch off indicator lamp for main power supply MCCB 主电源供电开关分闸指示灯
BL heating indicator lamp of generator 发电机加热指示
HS Emer. Generator heat control switch 应急发电机加热控制开关
ESB-5 OUT E.G. ONLINE SIGNAL TO 1EL (AC220V POTENTIAL SIGNAL) 输出应急发电机供电有源信号(AC220V)至 1EL
SINGLE LINE DIAGRAM OF THE EMER. SWITCHBOARD
SDG685-641-02
PAGE 7 OF 11
EMERGENCY GENERATOR CONTROL PANEL / AC380V LOAD PANEL 应急发电机控制屏/AC380V 负载屏(1/ESB)
NO. 序号
DESCRIPTION 项目
E-1 MAIN POWER SUPPLY 主电源供电开关
E-2 NO.2 STEERING GEAR PUMP STARTER #2 舵机油泵控制箱
1300x600x1900 ( length X width X height ) 1300x600x1900 (长 X 深 X 高)
3. 符号说明
Symbols explain
UV
低压脱扣
Under volt trip
M
电动合闸
Motor operated
SHT 分励脱扣
Shunt trip
DOL 直接启动
The structure of emergency switchboard and its installation
Installation position 安装位置
Emergency generator room 应急发电机间
Installation type 安装形式
Ground mounted 自立式,落地安装
主电源供电开关(E-1)相互联锁。
SINGLE LINE DIAGRAM OF THE EMER. SWITCHBOARD
SDG685-641-02
PAGE 4 OF 11
ACB (EACB) for emergency generator should be auto tripping when the main power normal, and it is to be interlocked with MCCB (E-1) on ESB for the main power supply. 6. 主电源供电开关(E-1)应能在主电源失电时自动脱扣, 主电源供电时自动合闸。 MCCB (E-1) on ESB for the main power supply should be auto tripping when the main power failure, and the MCCB (E-1) should be switched on automatically when the main power normal. 7. 应急发电机组在主电源失电时应能自动起动,并在 45 秒内自动连接于应急配电 板,向应急负载供电。应急发电机间风机应能在应急发电机供电时自动启动。