Techcon T309S VAV专用智能传感器

合集下载

Lutron occupancy sensor product 说明书

Lutron occupancy sensor product 说明书

occupancy sensor product guideLutron |12 |LutronASHRAE/IESNA 90.1 StandardThe American Society of Heating, Refrigerating, and Air Conditioning Engineers Inc. (ASHRAE)and the Illuminating Engineering Society of North America (IESNA) jointly sponsor the ASHRAE/ IESNA Standard 90.1, “Energy Standard for Buildings Except Low-Rise Residential Buildings.”This standard encourages the use of energy efficient lighting controls in design practice for both interior and exterior lighting. Most states have or will adopt energy codes based on this standard. One of the key lighting requirements in this widely adopted standard is:Automatic lighting shut-off:All buildings greater than 5000 square feet shall be equipped with an automatic control deviceto shut-off building lighting in all spaces. Lutron occupancy sensors that turn lights off within30 minutes after a space is vacated provideone solution for this requirement.IECC 2003 Lighting Control ProvisionsSimilar to ASHRAE/IESNA 90.1, the International Energy Conservation Code (IECC) has been adopted by states for minimum energy efficiency in commer-cial building design. As in the ASHRAE/IESNA 90.1 Standard, the IECC 2003 also has a mandatory requirement of automatic shut-off of lighting in build-ings larger than 5000 square feet. Lutron occupancy sensors are a perfect solution for this requirement. Furthermore, Lutron occupancy sensors provide a solution for the Light Reduction Controls requirement (Section 805.2.2.1), which states that areas having manually controlled lights must also have a manual lighting control that reduces the light level by at least 50% or an occupancy sensor can control the area. California Energy Commission(CEC) Title 24 Building StandardsThe California Energy Commission (CEC) created California's 2005 Building and Energy Efficiency Standards/Regulations for Residential and Nonresidential Buildings (Title 24), which provides mandatory lighting controls requirements for commercial and residential buildings. All Lutron occupancy sensors are CEC Title 24-compliant for commercial buildings. Lutron occupancy sensors provide an excellent solution to these keyTitle 24 provisions:Automatic shut-off:For every floor, all indoor lighting systems shallbe equipped with a separate automatic controlto shut off the lighting.Area control:Each area enclosed by ceiling-height partitions must have an independent switching or control device (occupancy sensor or manual switch) that: –is readily accessible; and–is located so that a person using the device can see the lights or area controlled by the switch,or so that the area being lit is annunciated; and –is able to override other devicesMulti-level lighting control:Any enclosed space 100 sq. ft. or larger that has a connected lighting load greater than 0.8 watts/sq. ft., and that has more than one luminaire shall use a multi-level lighting control (control that reduces lighting power by either continuous dimming, stepped dimming, or stepped switching while maintaining a reasonably uniform level of illuminance throughout the controlled space). The multi-level lighting controls must have one control step that is between 50% and 70% of design lighting power and at least one step of mini-mum output operating at less than 35% of full rated lighting system power (this could be completely off). Lutron occupancy sensors that switch alternate rows of lights are a solution for this requirement. Residential buildings:For newly constructed or remodeled residential buildings Title 24 requires the use of a manual-on occupancy sensors, fluorescent lights, or dimmers in most rooms of the home such as the bathroom, garage, utility room, hallway, bedroom, and living room. Lutron offers two models of wall switch occupancy sensors to meet this requirement,see pages 14 – 15. These ‘M’ models turn the lights on manually, when someone pushes the button, and they automatically turn the lights off when the room is unoccupied.Lutron |3Occupancy sensors are only one component of a larger energy saving strategy, which includes dimming, daylighting, and load shedding. Lutron occupancy sensors offer additional benefits when combined with a completeLutron lighting control system, such as an EcoSystem™fluorescent lighting control system or a RadioTouch™wireless remote lighting control system.4 |LutronLutron |5Typical occupancy sensors require manual adjustment of time and sensitivity settings to avoid false triggering.By analyzing occupancy patterns, Lutron self-adaptive occupancy sensors constantly update their time and sensitivity settings toensure that the sensors have the greatest accuracy. The occupancy sensors learn from their mistakes and make adjustments accordingly.Therefore, no manual sensitivity or timer adjustments are necessary –providing maintenance free “install and forget” operation.Lutron occupancy sensors feature self-adaptive technologyOccupancy sensor without self-adaptive technologyInterference repeatedly causes the occupancy sensor to falsely believe an occupant is in the room so the lights briefly turn on and then off again multiple times.Occupancy sensor with self-adaptive technologyOccupancy sensor automatically adjusts timing and sensitivity after the first false-on so the interference will not cause the repeated false-on situation to occur.6 |LutronUnoccupied Sensor Signal with Interference Spike Occupancy Sensor Timing and Sensitivity SettingsUnoccupied Sensor Signal with Interference Spike Occupancy Sensor Timing and Sensitivity SettingsChoose the technology most appropriate for thetype of activity, pg.8.steptechnology selection 1Determine the mounting type and placement basedon the location of activity within the space, pg.10.stepmounting type selection 2Determine the range of coverage ensuring that all appropriateareas of the space are within the sensor’s reach, pg.11.stepcoverage considerations 3Select the appropriate Lutron occupancy sensorfor your application, pg.11.stepfamily/model selection 4Lutron |7Choose the technology most appropriate for the type of activity.steptechnology selection 1Passive infrared (PIR)PIR technology senses occupancy by detecting the difference between heat emitted from the human body in motion and the background space. PIR sensors require an unobstructed line-of-sight for accurate detection.These sensors utilize a segmented lens which divides the coverage area into zones. Movement between these zones is interpreted as occupancy.Generally , PIR sensors are good at detecting major motion (e.g. walking) and work best in small, enclosed spaces with high levels of occupant movement.considerations:•Ensure a clear line-of-sight between the lens and the location of the activity •Ensure that there is a discernable temperature difference between occupant and ambient temperatureUltrasonic (US)Ultrasonic technology senses occupancy by bouncing ultrasonic sound waves (32kHz – 45kHz) off objects in a space and detecting a frequency shift between the emitted and reflected sound waves. Movement by a person or object within the space causes a shift in the wave frequency,which is interpreted as occupancy. Ultrasonic occupancy sensors are good at detecting minor motion (e.g. typing, reading) and do not require an unobstructed line-of-sight, thus making them suitable for applications such as an office with cubicles or a restroom with stalls.considerations:•Do not place within 6ft. of HVAC as this may cause false triggering •Avoid placement facing doors or exits as coverage may spill into adjacent areasDual technology (DT)Dual-technology occupancy sensors use both passive infrared and ultrasonic technologies for maximum reliability. These sensors also minimize the risk of false triggering (lights coming on when the space is unoccupied). Both US and PIR technologies must detect occupancy to turn lighting on, while continued detection by only one technology will keep lighting on.best for use in areas with:•an unobstructed view •high air flow •ceiling fansbest for use in areas with:•low air flow•partitions and dividers•a high level of minor motionbest performing sensor for most applications8 |Lutronstepmounting type selection 2Wall mount pg.16Use when:•Pendant fixtures present •Ceiling fans used•Ceiling height is greater than 12ft.•Integrating with Lutron lighting control systems or in stand-alone applicationsCeiling mount pg.18Use when:•Ceiling height is 12ft. or less •There are no obstructions such as ceiling fans and pendant fixtures•Integrating with Lutron lighting control systems or in stand-alone applicationsWall switch pg.14Use when:•Need an economical retrofit wallbox solution•Not integrating with a Lutron lighting control system •Application does not require dual technology•Room is small and enclosed with a clear point of entryexample of wall switch occupancy sensor with ultrasonic technology example of wall mount occupancy sensor with passive infrared technology example of ceiling mount occupancy sensor with dual technology4 f t .8 f t . – 12 f t .12 f t . o r l e s sDetermine the mounting type and placement based on thelocation of activity within the space and the following guidelines:wall switch occupancy sensorsLOS-S SeriesThe LOS-S series of sensors offer a direct and quick replacement of wall switches for stand-alone line voltage switching of small spaces. Ultrasonic sensors provide excellent detection of minor motion such as typing at a keyboard. Infrared detectors have good false tripping immunity, and are better suited for major motion such as walking.A two-circuit version of the PIR wall switch (LOS-S2IR-HD)is designed for dual-level lighting applications and allows for two primary input circuits, each with independentswitching. The ‘HD’ versions of this series have a hardened lens, which provides a barrier to accidental and vandal-imposed damage.Lutron offers ‘M’ models (LOS-SIR-M-WH and LOS-SIR-M-IV),which are manual-on occupancy sensors. Users push the button to turn the lights on and the lights turn off automatically when space is unoccupied. These ‘M’ models meet Title 24 energy code requirements for residential buildings in California.Key features:•Coverage from 900 sq. ft to 1000 sq. ft•Passive infrared (PIR) and ultrasonic (US) technologies •LOS-SUS model has self-adaptive technology which automatically adjusts timing and sensitivity •120/277 VAC dual voltage operation •Dual circuit with independent switching model available (LOS-S2IR)•LED test indicator•No power pack required•2 heavy-duty models ‘HD’ which are vandal resistantLOS-SIR-HD-WH shown actual sizewall mount occupancy sensorsLOS-W SeriesThe LOS-W series are wall-mounted sensors that are usedin spaces with pendant fixtures, ceiling fans, or high ceilings(greater than 12 ft. high). The passive infrared (PIR) versionhas good false tripping immunity and is well suited for majormotion. The dual-technology versions offer excellent minormotion detection via ultrasonic (US) technology to ensureoptimal power savings and occupancy detection.The LOS-W sensors all have self-adaptive technologythat eliminates the need for manual range adjustment.After proper mounting, the sensors automatically adjustsensitivity and timing to prevent false-off and false-onconditions. To control other building systems such asHVAC or security systems use the ‘R’ model, whichprovides an additional dry contact closure.Key features:•Coverage of 1600 sq. ft. if mounted at 8 ft. to 12 ft.from floor•Passive infrared (PIR), or dual-technology –both PIR and US•Self-adaptive sensors automatically adjust sensitivityand timing•20-24 VDC, Class 2 (PELV) low-voltage wiring•Integrate with Lutron systems (no power pack needed) orfunction as stand-alone controls using a Lutron power pack•Non-volatile memory (saved changes are stored duringloss of power)•Model with additional output (dry contact closure) available•8-second test mode to easily confirm proper operationLOS-WDT-WHshown actual sizeceiling mount occupancy sensorsLOS-C SeriesThe LOS-C series ceiling mount sensors offer a wide range of technologies and can either integrate into Lutron systems (no power pack needed) or function as stand-alone controls using a Lutron power pack. The ultrasonic sensors provide excellent detection of minor motion, such as typing at a keyboard. The passive infrared sensors provide false tripping immunity, and are better suited for major motion such as walking. The dual-technology versions combine both features to provide optimal power savings and occupancy detection.The LOS-C sensors all have self-adaptive technology that eliminates the need for manual adjustments. After correct mounting, the sensors automatically adjust sensitivity and timing to prevent false-off and false-on conditions. To control other building systems such as HVAC or security systems use the ‘R’ models, which provides an additional dry contact closure.Key features:•Coverage from 450 sq. ft. to 2000 sq. ft. mounted on an 8 ft. to 12 ft. ceiling•Passive infrared (PIR), ultrasonic (US) or dual technology (DT)•Self-adaptive sensors automatically adjust sensitivity and timing •20-24 VDC, Class 2 (PELV) low-voltage wiring •Non-volatile memory (saved changes are stored during loss of power)•Model with additional output (dry contact closure) available •8-second test mode to easily confirm proper operationLOS-CDT -2000-WHactual diameter: 4.5" (114 mm)power packsPP SeriesA Lutron power pack is required for wall and ceiling mount occupancy sensors used as a stand-alone lighting control.The power pack provides 24 VDC to the occupancy sensor,and accepts control input from the occupancy sensor,which it uses to switch the lighting load. This series includes a full line of voltages.The PP-SH is an auxiliary relay that allows for control of multiple lighting circuits or load types. The PP-SH draws power from another power pack and takes its control signal from the occupancy sensor. It counts as one of the three occupancy sensors connected to a power pack.Key features:•120, 277, 347 VAC power input @ 60 Hz •230 VAC power input @ 50/60 Hz •24 VDC, 100 mA power output•Plenum rated – complies with requirements for use in a compartment handling conditioned air •Switch rating:–20 A: 120/230/277 V ballast –15 A: 347 V ballast–15 A: 120 V incandescent•Supports up to 3 Lutron occupancy sensorsPP-120H actual size:W:3.69" (94 mm)H: 2.33" (59 mm)D: 1.36" (35 mm)The following are examples of Lutron suggested solutions to common single room applications. For further assistance in designing the right solution for your space, complete our Occupancy Sensor Design & Layout Request Form at /pdfspecs/occupancy_sensor_design.pdfor email us at ***************************Footnotes:1Use approximately half this value for excellent minor motion detection.2Self-adaptive technology: Automatic adjustments of sensitivity and timing so no calibration is required.3Passive infrared technology does not emit a signal into the space. Therefore, it uses less currentand is useful in rooms that may contain sensitive equipment such as medical facilities or laboratories.4California Energy Commission (CEC) residential Title 24-compliant.5Contact closure for integration with other building systems such as a security system or HVAC system. Also, these models can be used with Lutron RadioRA®and HomeWorks®Systems (power pack required).Note: All Lutron occupancy sensors are California Energy Commission (CEC) commercial Title 24-compliant. All ceiling and wall mount occupancy sensors require a power pack for stand-alone applications.Lutron World Headquarters Campus, Coopersburg, PennsylvaniaLutron’s first principleis to take care of our customer.Commitment to innovationLutron has been dedicated to producing innovative lighting controls for commercial buildings of every type and style since 1961.This dedication is matched by our commitment to quality, performance, value and service for our customers.World-class qualityLutron quality is fueled by a relentless pursuit of the highest standards. Constant improvement activities include an integrated quality system, strict engineering guidelines, and world-class manufacturing processes.Comprehensive lighting control solutionsfor electric and natural lightLutron is your comprehensive resource for lighting control solutions for any commercial or institutional application.•Architectural dimming systems•Daylighting•Low-voltage switching systems•Floor plan based control software•Lighting management systems•Integrated lighting automation systems•Factory service plansPlease contact us for information on Lutron residentiallighting control products.Worldwide sales and service The Lutron Team is hereto support you wheneveryou need us.•Barcelona•Beijing•Berlin•Hong Kong•London•Madrid•Mexico City•Paris•Sao Paulo•Shanghai•Singapore•TokyoTechnical Support:24 Hours/7 Days1.800.523.9466Customer Service:8am-8pm ET1.888.LUTRON1Internet Support:/occsensorsCover photograph: Genzyme Center, Cambridge, MA, USA.Photograph © Peter Vanderwarker. Behnisch Behnisch and Partner Architects.World HeadquartersLutron Electronics Co., Inc.7200 Suter RoadCoopersburg, PA 18036-1299U.S.A.Tel:+1-610-282-3800Fax :+1-610-282-1243Email:*******************European Headquarters Lutron EA Ltd.Lutron House 6 Sovereign Close London E1W 3JF , UKTel: +44-(0)207-702-0657Fax: +44-(0)207-480-6899Email:***********************Technical Support: 24 Hours/7 Days 1.800.523.9466Customer Service: 8am-8pm ET 1.888.LUTRON1Internet Support:/occsensorsWorldwide sales and serviceLighting control application experts are available 24 hours/7 days a week to assist you. Service is available in over 140 languages.。

Techcon 309L-P1 VAV控制器

Techcon 309L-P1 VAV控制器

Techcon 309LP1Techcon LONMARK® 认证可编程变风量控制器-4 -4 -2 -1 应用- 适用于单风道变风量控制应用。

- 控制设备包括:护壁板, 风道加热器/制冷,多级再加 热,风扇,阀门,灯光,等等。

- 可配合采用其它传感器及外围设备。

路通用输入 路可控硅输出(数字) 路通用输出 路压力传感器特点互操作性 - 采用 LONWORKS® 技术,实现控制器之间点对点的通 讯,无需任何第三方设备。

- 符合 LONMARK® 认证 3.4。

硬件 - 内置定扭矩风阀执行器,提高使用寿命。

- 综合阀位反馈,不必定期重复初始化风阀位置。

- 内置高精度气流传感器,适合独立单风道应用。

- 4 路通用输入 (软件配置)。

- 4 路可控硅输出 (数字量 or PWM)。

- 2 路通用输出。

- 128K 闪存可以用于应用设定和控制逻辑并且能够储存 超过 12000 个事件。

- Servic pin 的位置非常容易触发。

软件特点 60 个网络变量包括: - 18 个 NVIs,,可变类型,可变长度 - 18 个 NVOs,可变类型,可变长度 - 支持内置风机绑定 ® - 可采用 LNS plug-in 编程 自由编程对象 - 配置,编码,标示储存在控制内,提高备份能力。

- 内置多种应用模式:PID,时间控制器,最优启动.。

- 可以查阅所有的内置点(常量, 变量等),每 15 个变量 有 10 个 UNVT。

Techcon 309L-P1 采用最先进的控制技术,比传统的 VAV 控制器 更灵活更可靠,采用无刷电机执行器,与传统有刷电机相比延长 了使用寿命。

16 位模数转换提供了高精度的输入和高精度的风道 压力传感器的读值,并且顾及到 VAV 系统平衡的调节精度。

Techcon 309L-P1 控制器具备扩展 I/O 能力,包括 4 路通用 (模 拟量/数字量 l 输入, 4 路数字量输出和 2 路通用输出. Techcon 309L-P1 控制器采用 LonTalk®通讯协议.采用认证的传感器输入 和执行器输出。

e-switch 产品说明书

e-switch 产品说明书

RoHSN A V I G A T I S W I T C H E R O C K E R S W I T C H E S R O T A R Y S W I T C H E S S L I D E S W I T C H E S S N A P A C T I O N S W I T C H E ST A C T I L E SW I T C H E ST O G G L E S W I T C H E S C A P O P T I O N S P U S H B U T T O N S W I T C H E SAudio / Visual Security Devices Industrial ControlsElectrical Housewares Kiosks SpecificationsFeatures & BenefitsApplications / Markets• 19mm diameter panel cutout • RGB LED option• Dot, ring or power symbol illumination available • Multiple function options • IP65 rated • SPDT & DPDT•Soldered wire leads (300mm long) optionalElectrical Rating: 2A, 24VDC Electrical Life: 50,000 CyclesContact Resistance: 50mΩ Max. Insulation Resistance: 1000 MΩ Min. Dielectric Strength: 2,000VACOperating/Storage Temperature: -20°C to 55°C Travel: 2.50mm Moisture Protection: IP65Contact Arrangement: SPDT, DPDT Actuation Force: 4 NPanel Thickness: 1-11mmMounting Nut Torque: 5-14NmMedical EquipmentANTI-VANDAL SWITCHES DETECTOR SWITCHESDIP SWITCHESKEYLOCK SWITCHESROCKER SWITCHES ROTARY SWITCHESSLIDE SWITCHES SNAP ACTION SWITCHESTACTILE SWITCHES TOGGLE SWITCHESCAP OPTIONSNAVIGATION SWITCHESPUSHBUTTON SWITCHESANTI-VANDAL SWITCHESStandard LEDFunctions 3, B, G & HSPDT LED SchematicRECOMMENDED "D" PANEL CUTOUTMAX. PANEL THICKNESS 11.0mm "D" HOUSING TO BE USED WITHPOWER SYMBOL OR CUSTOM GRAPHICSRECOMMENDED PANEL CUTOUTMAX. PANEL THICKNESS 11.0mmDPDT ILLUMINATED OPTION SHOWN LED (+) AND (-)TERMINALS ARE NOT INCLUDED ON THENON-ILLUMINATED OPTIONTERMINALS 4,5 AND 6 ARE NOT ON THE SPDT VERSIONFUNCITONS 3 & B ARE SPDT FUNCTIONS G & H ARE DPDT18.45 .15.726 .006 in []19.00 -.00.20+.748-.000.008+ in[]-(REVERSE)(FORWARD)(-)+-2311(+)+231119.00 -.00.20+.748-.000.008+ in[]11443265(+)-(REVERSE)+(FORWARD)-(-)+1144326536.9 1.01.45 .04 in []1.80[.071 in]M19 X 1.038.0 1.01.50 .04 in []22.00[ .866 in]15.80[ .622 in]13.60[ .535 in]RING ILLUMINATED(OPTIONAL)12.00[.472 in].50[.020 in](+)(-)TERMINAL 6TERMINAL 5TERMINAL 4TERMINAL 3TERMINAL 2TERMINAL 15.20[.205 in]10.00[.394 in]2.80[.110 in]SPDT Non Ill SchematicDPDT LED SchematicDPDT Non Ill SchematicS W I T C H E SD E T E C T O R S W I T C H E SD I P S W I T C HE SK E Y L O C K S W I T C H E SN A V I G A T I O N S W I T C H E SP U S H B U T T O N S W I T C H E SR O C K E R S W I T C H E SR O T A R Y S W I T C H E S S L I D E S W I T C H E SS N A P A C T I O N S W I T C H E S T A C T I L E S W I T C H E ST O G G L E S W I T C H E SC A P O P T I O N SA N T I -V A N D A L S W I T C H E S Y Function w/Solder TerminalsSPDT LED SchematicSPDT Non Ill SchematicRECOMMENDED "D" PANEL CUTOUTMAX. PANEL THICKNESS 11.0mm "D" HOUSING TO BE USED WITHPOWER SYMBOL OR CUSTOM GRAPHICSRECOMMENDED PANEL CUTOUTMAX. PANEL THICKNESS 11.0mm4+1-(REVERSE)(FORWARD)(-)+-4231(+)+19.00 -.00.20+.748-.000.008+ in[]18.45 .15.726 .006 in []19.00 -.00.20+.748-.000.008+ in[]4231RING ILLUMINATION(OPTIONAL)22.00[.866 in]12.0[.47 in]15.4[.606 in]ILLUMINATED OPTION SHOWN LED (+) AND (-) TERMINALS ARE NOT ON THE NON-ILLUMINATED OPTIONM19 X 1.03.80[.150 in] 2.00[.079 in]33.4 1.01.31 .04 in []9.80[.386 in](+)(-)7.60[.299 in] 2.80[.110 in].50[.020 in]7.60[.299 in]TERMINAL 1TERMINAL 3TERMINAL 2TERMINAL 4ANTI-VANDAL SWITCHESDETECTOR SWITCHESDIP SWITCHESKEYLOCK SWITCHESNAVIGATION SWITCHESPUSHBUTTON SWITCHESROCKER SWITCHESROTARY SWITCHES SLIDE SWITCHES SNAP ACTION SWITCHESTACTILE SWITCHES TOGGLE SWITCHESCAP OPTIONSANTI-VANDAL SWITCHES Y Function w/Screw TerminalsRECOMMENDED "D" PANEL CUTOUTMAX. PANEL THICKNESS 11.0mm "D" HOUSING TO BE USED WITHPOWER SYMBOL OR CUSTOM GRAPHICSRECOMMENDED PANEL CUTOUTMAX. PANEL THICKNESS 11.0mm-(REVERSE)(FORWARD)(-)+-4231(+)+423119.00 -.00.20+.748-.000.008+ in[]18.45 .15.726 .006 in []19.00 -.00.20+.748-.000.008+ in[] 22.00[ .866 in]15.40[ .606 in]12.00[ .472 in]RING ILLUMINATED(OPTIONAL)M19 X 1.02.00[.079 in]34.6 1.01.36 .04 in []15.60[.614 in](+)TERMINAL 4TERMINAL 2(-)TERMINAL 1TERMINAL 39.60[.378 in]7.60[.299 in]7.60[.299 in]SPDT LED SchematicSPDT Non Ill SchematicA S W I T C H E SD E T E C T O R S W I T C H E SD I P S W I T C HE SK E Y L O C K S W I T C H E SN A V I G A T I O N S W I T C H E S P U S H B U T T O N S W I T C H E S R O C K E R S W I T C H E SR O T A R Y S W I T C H E S S L I D E S W I T C H E S S N A P A C T I O N S W I T C H E S T A C T I L E S W I T C H E ST O G G L E S W I T C H E SC A P O P T I O N SN T I -V A N D A L S W I T C H E S RGB Led IlluminationFunctions 3 & BRECOMMENDED "D" PANEL CUTOUTMAX. PANEL THICKNESS 11.0mm "D" HOUSING TO BE USED WITHPOWER SYMBOL OR CUSTOM GRAPHICSRECOMMENDED PANEL CUTOUTMAX. PANEL THICKNESS 11.0mm1.8[.07 in]36.9 1.01.45 .04 in [].50[.020 in]38.0 1.01.50 .04 in []RED (+)GREEN (+)BLUE (+)(-)121319.00 -.00.20+.748-.000.008+ in[]18.45 .15.726 .006 in []19.00 -.00.20+.748-.000.008+ in[]12.00[.472 in] 22.00[ .866 in]15.80[ .622 in]13.60[ .535 in]RING ILLUMINATION(OPTIONAL)RED (+)GREEN (+)BLUE (+)(-)TERMINAL 1TERMINAL 2TERMINAL 35.20[.205 in]10.00[.394 in]2.80[.110 in]SPDT RGB LED SchematicANTI-VANDAL SWITCHES DETECTOR SWITCHESDIP SWITCHESKEYLOCK SWITCHESNAVIGATION SWITCHESPUSHBUTTON SWITCHES ROCKER SWITCHESROTARY SWITCHES SLIDE SWITCHESSNAP ACTION SWITCHESTACTILE SWITCHES TOGGLE SWITCHES CAP OPTIONSPUSHBUTTON SWITCHES ANTI-VANDAL SWITCHESActuator OptionsGraphic OptionsFlat Non-Illuminated Flat Dot Illuminated Flat Ring IlluminatedORIENTATION FLAT FOR GRAPHIC8.00[.315 in]ORIENTATION FLAT FOR GRAPHICRINGILLUMINATIONDOTILLUMINATION9.00[.354 in]6.0[.24 in]1.60[.063 in]22.00[ .866 in] 15.40[ .606 in]22.00[ .866 in]22.00[ .866 in]15.80[ .622 in] 13.60[ .535 in]ILLUMINATED8.00[.315 in]LASER ETCHED 6.50[.256 in]High ActuatorFlat ActuatorA S W I T C H E SD E T E C T O R S W I T C H E SD I P S W I T C HE S K E Y L O C K S W I T C H E S N A V I G A T I O N S W I T C H E S P U S H B U T T O N S W I T C H E SR O C K E R S W I T C H E SR O T A R Y S W I T C H E SS L I D E S W I T C H E S S N A P A C T I O NS W I T C H E S T A C T I L E S W I T C H E ST O G G L E S W I T C H E SC A P O P T I O N SN T I -V A N D A L S W I T C H E S Standard LEDWire LeadRECOMMENDED "D" PANEL CUTOUTMAX. PANEL THICKNESS 11.0mm "D" HOUSING TO BE USED WITHPOWER SYMBOL OR CUSTOM GRAPHICSRECOMMENDED PANEL CUTOUTMAX. PANEL THICKNESS 11.0mmBOTTOM VIEW SHOWN WITHOUTWIRING** WIRE LEADS PROVIDED ARE DEPENDANT ON THE FUNCTION AND/OR ILLUMINATION SELECTED **19.00 -.00.20+.748-.000.008+ in[]18.45 .15.726 .006 in []19.00 -.00.20+.748-.000.008+ in[]13.0 2.0.5 .1 in []300.0 10.011.8 .4 in [](8) WIRE, 24 AWG,AWM UL1015 WITH ENDS PRE-STRIPPEDHEATSHRINK OVER SOLDERED CONNECTIONSWIRE TIE25.4[1.0 in]()(-)TERMINAL 3(+)SWITCH WIRELENGTH SW1-1WIRE, 24AWG AWM UL1015, YELLOW 300.0 [11.8 in]SW1-2WIRE, 24AWG AWM UL1015, BLUE 300.0 [11.8 in]SW1-3WIRE, 24AWG AWM UL1015, GREEN 300.0 [11.8 in]SW1-4WIRE, 24AWG AWM UL1015, PURPLE 300.0 [11.8 in]SW1-5WIRE, 24AWG AWM UL1015, ORANGE 300.0 [11.8 in]SW1-6WIRE, 24AWG AWM UL1015, WHITE 300.0 [11.8 in]SW1- (+)WIRE, 24AWG AWM UL1015, RED 300.0 [11.8 in]SW1- (-)WIRE, 24AWG AWM UL1015, BLACK300.0 [11.8 in]TERMINAL 1TERMINAL 2TERMINAL 4TERMINAL 5TERMINAL 615.0 2.0.6 .1 in []ANTI-VANDAL SWITCHES DETECTOR SWITCHES DIP SWITCHES KEYLOCK SWITCHESNAVIGATION SWITCHESPUSHBUTTON SWITCHES ROCKER SWITCHESROTARY SWITCHESSLIDE SWITCHES SNAP ACTION SWITCHESTACTILE SWITCHES TOGGLE SWITCHESCAP OPTIONSPUSHBUTTON SWITCHES ANTI-VANDAL SWITCHESRGB LEDWire LeadRECOMMENDED "D" PANEL CUTOUTMAX. PANEL THICKNESS 11.0mm "D" HOUSING TO BE USED WITHPOWER SYMBOL OR CUSTOM GRAPHICSRECOMMENDED PANEL CUTOUTMAX. PANEL THICKNESS 11.0mmBOTTOM VIEW SHOWN WITHOUTWIRING** WIRE LEADS PROVIDED ARE DEPENDANT ON THE FUNCTION AND/OR ILLUMINATION SELECTED **19.00 -.00.20+.748-.000.008+ in[]18.45 .15.726 .006 in []19.00 -.00.20+.748-.000.008+ in[]WIRE TIE(7) WIRE, 24 AWG,AWM UL1015 WITH ENDS PRE-STRIPPEDHEATSHRINK OVER SOLDERED CONNECTION25.4[1.0 in]()13.0 2.0.5 .1 in []300.0 10.011.8 .4 in []GREEN (+)RED (+)SWITCH WIRELENGTH SW1-1WIRE, 24AWG AWM UL1015, ORANGE 300.0 [11.8 in]SW1-2WIRE, 24AWG AWM UL1015, WHITE 300.0 [11.8 in]SW1-3WIRE, 24AWG AWM UL1015, YELLOW 300.0 [11.8 in]SW1-RED (+)WIRE, 24AWG AWM UL1015, RED 300.0 [11.8 in]SW1-GREEN (+)WIRE, 24AWG AWM UL1015, GREEN 300.0 [11.8 in]SW1-BLUE (+)WIRE, 24AWG AWM UL1015, BLUE 300.0 [11.8 in]SW1- (-)WIRE, 24AWG AWM UL1015, BLACK300.0 [11.8 in]TERMINAL 2TERMINAL 3TERMINAL 1BLUE (+)(-)15.0 2.0.6 .1 in []。

PGA309 程序可编程压力传感器信号条件器:为非线性压力传感器世界带来线性说明书

PGA309 程序可编程压力传感器信号条件器:为非线性压力传感器世界带来线性说明书
• Offset
– Variations @ 25oC – Linear changes with Temperature – NonLinear changes with Temperature
• Bandwidth
– <4kHz for most pressure sensor applications
80
75
70
65
60
55
50
45
40
35
30
25
20
15
Pnl = 2.5%Span
10
5
0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6 0.65 0.7 0.75 0.8 0.85 0.9 0.95 1
0
Pin
1
Pmax Normalized Pressure S timulus
-2.5%< Pnl <+2.5% (of Span)
14
Pressure (PSI)
Pnl (Pressure NonLinearity) Example
100
Pin Pnonl i n( Pi n)
0
NonLinear Pressure Out put o f Sensor 100
95
90
85
Sp an TC Vs. Temp erature
10 8 6 4
SpanT C1(T) 2 0 2 4 6 8
10
12
14
SpanTC1= -0.2%Span/°C
16
− 20 18
20 40 31 22 13 4 5 14 23 32 41 50 59 68 77 86 95 104113122131 140

奥美晨曦系列微波传感器说明书

奥美晨曦系列微波传感器说明书

OS100 SERIES Mini-Infrared Transmitter e-mail:**************For latest product manuals: Shop online at User’s G ui d e***********************Servicing North America:U.S.A. Omega Engineering, Inc.Headquarters: Toll-Free: 1-800-826-6342 (USA & Canada only)Customer Service: 1-800-622-2378 (USA & Canada only)Engineering Service: 1-800-872-9436 (USA & Canada only)Tel: (203) 359-1660 Fax: (203) 359-7700e-mail:**************For Other Locations Visit /worldwideThe information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.Table of ContentsSection ...................................................................PageSafety Warnings and IEC Symbols (iii)Caution and Safety Information (iii)Section 1 Introduction ....................................................................1-1Section 2Installation ......................................................................1-12.1 Unpacking and Inspection ......................................1-12.2 Electrical Connection ..............................................2-1Section 3Operation ........................................................................3-13.1 Main Board ................................................................3-13.2 Ambient Temperature ..............................................3-23.3 Atmospheric Quality ................................................3-33.4 Measuring Temperature ..........................................3-33.5 Alarm Setting ............................................................3-43.6 Adding Extension Cable...........................................3-4Section 4 Laser Sight Accessory ...................................................4-14.1 Warning and Cautions .............................................4-14.2 Operating the Laser Sight Accessory .....................4-1Section 5 Specifications .................................................................5-15.1 General .......................................................................5-15.2 Laser Sight Accessory (OS100-LS) ..........................5-2Section 6Emissivity Table .............................................................6-1iTable of FiguresFigure Description Page2-1Power Supply & Analog Output Connections ..........2-12-2 Alarm Output Connection ............................................2-13-1 Main PC Board ...............................................................3-23-2 Sensor..............................................................3-2Housing3-3 Optical Field of View .....................................................3-43-4Setting the Temperature Engineering Unit..................3-43-5Mounting Bracket OS100-MB .......................................3-53-6Water Cooling Jacket, OS100-WC ................................3-53-7Typical Water Cool Jacket Assembly ...........................3-53-8Air Purge Collar, OS100-AP..........................................3-63-9DIN Rail Mounting Adapter, OS100-DR ....................3-63-10NEMA-4 Aluminum Enclosure ....................................3-64-1Laser Sighting Accessory, OS100-LS ............................4-24-2Laser Warning Label ......................................................4-2iiSafety Warnings and IEC SymbolsThis device is marked with international safety and hazard symbols in accordance with IEC 1010. It is important to read and follow all precautions and instructions in this manual before operating or commissioning this device as it contains important information relating to safety and EMC. Failure to follow all safety precautions may result in injury and or damage to your calibrator. IEC symbols DescriptionCaution and Safety Information• If the equipment is used in a manner not specified in this manual, the protection provided by the equipment may be impaired.• The installation category is one (1).• There are no user replaceable fuses in this product• The output terminals of this product are for use with equipment (digital meters, chart recorders, etc,) which have no accessible five parts. Such equipment should comply with all the applicable safety requirements.• Do not operate the equipment in flammable or explosive environments.• All connections to the thermometer should be made via a shielded cable, 24 AWG stranded wire with the following ratings: 300V , 105°C (221°F), PVC insulation.• Power must be disconnected before making any electrical connections.• The power supply used to power the thermometer should be VDE or UL approved with the following ratings: 12 to 24vdc @150mA with overload protection of 500mA.iiiCaution, refer to accompanying documentsDirect Current Laser SymbolFrame or ChassisNOTES: ivSection 1 - IntroductionThe low cost OS101 mini-infrared transmitter provides non-contacttemperature measurement for industrial applications. The unit measures atemperature range of -18 to 538°C (0-1000°F) and provides a linear analogoutput of either 4-20 mA, 0-5 VDC, K type TC, 1 mV/°C, or 1 mV/°F.The new OS102 mini-infrared transmitter has all the functions of OS101plus a built-in LED display that shows the measured temperature indegrees F or degrees C which is switchable in the field.The miniature sensor head design 2.5 cm dia. x 6.3 cm Length (1" x 2.5") isideal for measuring temperature in confined, and hard to reach places.The aluminum sensor head as well as the rugged electronic housing (Diecast Aluminum) are NEMA-4 rated.The sensor head is connected to the electronic housing via a 1.82 m (6 feet)shielded cable as standard. The unit provides field adjustable alarmoutput.Section 2 - Installation2.1UnpackingRemove the packing list and verify that you have received all yourequipment. If you have any questions about the shipment, please callCustomer Service at:1-800-622-2378 or 203-359-1660. We can also be reached on the internet:e-mail:**************When you receive the shipment, inspect the container and equipment forany signs of damage. Note any evidence of rough handling in transit.inspection. After examination and removing contents, save packing material and carton in theevent reshipment is necessary.The following items are supplied in the box:• The infrared transmitter including the sensor head and the 1.82 m(6 feet) shielded cable• User's Manual• Mounting Nut1-1The following describes the ordering information:OS102 or OS101 - MA- *,**, where The following optional accessories are available:Here are the Features of OS101 and OS102 infrared transmitters:2.2Electrical Connection Sensor Head Cable - The Sensor head is pre-wired to a 1.8 m (6 feet)shielded cable. Plug & lock-in the male connector to the mating female connector on the aluminum housing.Power & Output Connection - Open the cover of the main aluminum housing. Slide the cable through the strain relief and connect the wires to the terminal block on the board as shown in Fig. 2-1. For Alarm output connection, refer to Fig. 2-2.2-1MA - 4/20 mA output V1 - 0 to 5 VDC output K - Thermocouple output, K type MV - Millivolt output C - 1 mV/°C output F - 1 mV/°F output HT- High temperature sensor head3-1Figure 2-2. Alarm Output Connection Section 3 - Operation3-1Main BoardThe Main Board is shown in Fig. 3-1. Here are the important components on the board:(1) - Terminal Block for Power & Output connections(2) - Single Turn Potentiometer to adjust Emissivity in tenths (0.x_)(3) - Single Turn Potentiometer to adjust Emissivity in hundreds (0._x)(4) -Slide switch to select between real time (Normal Operation) and alarm set point(5) - Alarm set point adjust, P4(6) - Sensor Head connection(7) - Input Zero adjust, P3(8) - Input Span adjust, P2(9) - Output Zero adjust, P5(10) - Output Span adjust, P6Figure 3-1. Main PC Board3.2Ambient TemperatureThe Sensing head can operate in an ambient temperature of 0 to 70°C (32to 158°F). The Sensing head in the high temperature model (-HT) can operate in an ambient temperature of 0 to 85°C (32 to 185°F) without any cooling required. The Sensing head can operate up to 200°C (392°F) using the water cool jacket accessory OS100-WC (See Fig. 3-6).There is a warm up period of 3 minutes after power up. After the warm up period, temperature measurement can be made.When the ambient temperature around the sensor head changes abruptly,the sensor head goes through thermal shock. It takes a certain amount of time for the sensor head to stabilize to the new ambient temperature. For example, it takes about 30 minutes for the sensor head to stabilize going from 25°C to 50°C (77 to 122°F) ambient temperature.The sensor head dimensions are shown in Fig. 3-2.Figure 3-2. Sensor Housing3-23-33.3Atmospheric QualityEnvironments with smoke, dust, and fumes dirty up the optical lens, and cause erroneous temperature readings. To keep the surface of the optical lens clean, the air purge collar accessory is recommended, OS100-AP , See Fig. 3-7.3.4Measuring TemperatureBefore starting to measure temperature, make sure that the following check list is met:ߜ The power and analog output connections are made (Fig. 2-1).ߜThe sensor head is connected to the main unit.ߜThe slide switch (SW1) on the main board is set to real time (Fig. 3-1).ߜThe target is larger than the optical field of view of the sensor head (Fig. 3-3).ߜThe emissivity adjustment on the main board is set properly (Fig. 3-1).ߜThe output load is within the product specification.On OS102 transmitters, follow these additional steps:ߜ The temperature display is set to °F or °C (Fig. 3-4)ߜ For 4-20mA output models, make sure an output load is added, ie. 250ohms.Figure 3-3. Optical Field Of ViewFigure 3-4. Setting the Temperature Engineering Unit3.5Alarm SettingThe unit provides 0-100% alarm set point adjustment. Here is an exampleof an alarm setting.• An OS101-MA(4/20 mA output), the alarm is to be set at 400°Ftemperature.• Connect the alarm output as shown in Fig. 2-2.• Set the slide switch (SW1) on the main board to the Alarm position.• Measure the analog output, and set the Potentiometer P4 until theoutput reads 10.4 mA which is 40% (400°F) of the temperature range.40 x (20-4)[10.4mA=+ 4]100• Set the slide switch (SW1) back to the Real Time position.• If the temperature reading is below the alarm set point, the alarmoutput stays high, otherwise it goes low.On the OS102, you can set the alarm set point directly based on thetemperature display.3.6Adding Extension CableYou can add extension cable between the Sensor Head and the mainelectronic housing up to 15.2 m (50 feet). After adding the extension cable,the Zero input potentiometer, P3 may be re-adjusted. (See Fig. 3-1, forproper analog output reading)The following figures show the mounting bracket (OS100-MB), Watercooling jacket (OS100-WC), Air purge collar (OS100-AP), DIN RailMounting adapter (OS-100-DR), and the main aluminum enclosure. TheDIN Rail Mounting adapter (OS100-DR) is mounted to the bottom of themain aluminum enclosure using two 4-40 screws.A typical water cool jacket assembly is shown in Fig. 3-7, on the following page.1. Mounting Nut2. Mounting Bracket3. Water Cool Jacket4. Sensor Head3-4Figure 3-5. Mounting Bracket OS100-MBFigure 3-6. Water Cooling Jacket, OS100-WCFigure 3-7. Typical Water Cool Jacket Assembly3-5Figure 3-8. Air Purge Collar, OS100-APFigure 3-9. DIN Rail Mounting Adapter, OS-100-DRFigure 3-10. NEMA-4 Aluminum Enclosure3-6Section 4 - Laser Sight Accessory4.1Warning and Cautionsbelow:•Use of controls or adjustments or performance of procedures other than those specified here may result in hazardous radiation exposure.• Do not look at the laser beam coming out of the lens or view directly with optical instruments - eye damage can result.• Use extreme caution when operation the laser sight accessory • Never point the laser accessory at a person • Keep out of the reach of all children4.2Operating the Laser Sight AccessoryThe laser sight accessory screws onto the front of the sensor head. This accessory is only used for alignment of the sensor head to the target area.After the alignment process, the accessory has to be removed from the front of the sensor head before temperature measurement.The laser sight accessory is powered from a small compact battery pack (included with the accessory). Connect the battery pack to the accessory using the cable provided. Aim at the target, and turn on the battery power using the slide switch on the battery pack. Adjust the sensor head position so that the laser beam points to the center of the target area. Turn off the battery pack, and remove the laser sighting accessory from the sensor head. See Fig. 4-1 for reference.4-14-2Figure 4-2. Laser Warning LabelSection 5 - Specifications5.1 - GeneralTemperature Range-18 to 538°C (0 to 1000°F)Accuracy @ 22°C (72°F)±2% of Rdg. or 2.2°C (4°F) whichever is ambient temperature & greateremissivity of 0.95 or greaterOptical Field of View6:1 (Distance/Spot Size)Repeatability±1% of Rdg.Spectral Response 5 to 14 micronsResponse Time150 msec (0 to 63% of final value)Emissivity Range0.1 to 0.99, adjustableOperating Ambient TemperatureMain Transmitter0 to 50°C (32 to 122°F)Sensor Head0 to 70°C (32 to 158°F)Sensor Head (-HT Model)0 to 85°C (32 to 185°F)Sensor Head with OS100-WC(Water Cooling Jacket)0 to 200°C (32 to 392°F)Operating Relative Humidity Less than 95% RH, non-condensingWater Flow Rate for OS100-WC0.25 GPM, room temperatureThermal Shock About 30 minutes for 25°Cabrupt ambient temperature change Warm Up Period 3 minutesAir Flow Rate for OS100-AP 1 CFM (0.5 Liters/sec.)Power12 to 24 VDC @ 100 mAAnalog OutputsMV-F 1 mV/°FMV-C 1 mV/°CK K Type TC - OS101 onlyMA 4 to 20 mAV10 to 5 VDCOutput Load requirementsMin. Load (0 to 5VDC) 1 K-OhmsMax. Load (4 to 20 mA)(Supply Power - 4 )/20 mATransmitter Housing NEMA-4 & IP65, Die Cast AluminumSensor Head Housing NEMA-4 , AluminumAlarm Output Open Drain, 100 mAAlarm Set Point0 to 100% , Adjustable via P4Alarm Deadband14°C (25°F)5-15-25.1 - General Con’t.DimensionsSensor Head25.4 OD. x 63.5 mm L(1" OD. x 2.5" L)Main Housing, OS10165.5 W x 30.5 H x 115.3 mm L(2.58" W x 1.2" H x 4.54" L)Main Housing, OS10265.5 W x 55.9 H x 115.3 mm L(2.58" W x 2.2" H x 4.54" L)Weight 272 g (0.6 lb)5.2Laser Sight Accessory (OS100-LS)Wavelength (Color)630 - 670 nm (Red)Operating Distance (Laser Dot)Up to 9.1 m (30 ft.)Max. Output Optical Power Less than 1 mW at 22°F ambienttemperature.European Classification Class 2, EN60825-1/11.2001Maximum Operating current45 mA at 3 VDCFDA Classification Complies with 21 CFR 1040.10,Class II Laser ProductBeam Diameter 5 mmBeam Divergence< 2 mradOperating Temperature0 to 50°C (32 to 122°F)Operating Relative Humidity Less than 95% RH, non-condensingPower Switch ON / OFF , Slide switch on the BatteryPackPower Indicator Red LEDPower Battery Pack, 3 VDC (Consists of two 1.5VDC AA size Lithium Batteries) Laser Warning Label Located on the head sight circumferenceIdentification Label Located on the head sight circumferenceDimensions38 DIA x 50.8 mm L(1.5" DIA x 2" L)Section 6 - Emissivity Table6-1Material Emissivity (ε)Aluminum – pure highly polished plate . . . . . . . . . . . . . . . . . . . . . . . . 0.04 to 0.06Aluminum – heavily oxidized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.20 to 0.31Aluminum – commercial sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.09Brass – dull plate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.22Brass – highly polished, 73.2% Cu, 26.7% Zn. . . . . . . . . . . . . . . . . . . . . . . . . 0.03Chromium – polished. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.08 to 0.36Copper – polished. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.05Copper – heated at 600°C (1112°F). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.57Gold – pure, highly polished or liquid. . . . . . . . . . . . . . . . . . . . . . . . . 0.02 to 0.04Iron and steel (excluding stainless)– polished iron . . . . . . . . . . . . . . . . 0.14 to 0.38Iron and steel (excluding stainless)– polished cast iron. . . . . . . . . . . . . . . . . . . 0.21Iron and steel (excluding stainless)– polished wrought iron . . . . . . . . . . . . . . . 0.28Iron and steel (excluding stainless)– oxidized dull wrought iron . . . . . . . . . . . . 0.94Iron and steel (excluding stainless)– rusted iron plate . . . . . . . . . . . . . . . . . . . 0.69Iron and steel (excluding stainless)– polished steel. . . . . . . . . . . . . . . . . . . . . . 0.07Iron and steel (excluding stainless)– polished steel oxidized at600°C (1112°F). . . . . . . . . . . . . . . . . . . . 0.79Iron and steel (excluding stainless)– rolled sheet steel . . . . . . . . . . . . . . . . . . . 0.66Iron and steel (excluding stainless)– rough steel plate . . . . . . . . . . . . . 0.94 to 0.97Lead – gray and oxidized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.28Mercury . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.09 to 0.12Molybdenum filament . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.10 to 0.20Nickel – polished . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.07Nickel – oxidized at 649 to 1254°C (1200°F to 2290°F). . . . . . . . . . . 0.59 to 0.86Platinum – pure polished plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.05 to 0.10Platinum – wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.07 to 0.18Silver – pure and polished . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.02 to 0.03Stainless steel – polished . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.07Stainless steel – Type 301 at 232 to 942°C (450°F to 1725°F). . . . . . . 0.54 to 0.63Tin – bright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.06Tungsten – filament . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.39Zinc – polished commercial pure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.05Zinc – galvanized sheet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.23M E T A L S6-2Material Emissivity (ε) Asbestos Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.96 Asphalt, tar, pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.95 to 1.00 Brick– red and rough . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.93 Brick– fireclay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.75 Carbon– filament . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.53 Carbon– lampblack - rough deposit . . . . . . . . . . . . . . . . . . . . . . . . . .0.78 to 0.84 Glass- Pyrex, lead, soda . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.85 to 0.95 Marble– polished light gray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.93 Paints, lacquers, and varnishes– Black matte shellac . . . . . . . . . . . . . . . . . . . .0.91 Paints, lacquers, and varnishes– aluminum paints . . . . . . . . . . . . . . . .0.27 to 0.67 Paints, lacquers, and varnishes– flat black lacquer . . . . . . . . . . . . . . .0.96 to 0.98 Paints, lacquers, and varnishes– white enamel varnish . . . . . . . . . . . . . . . . . .0.91 Porcelain– glazed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.92 Quartz– opaque . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.68 to 0.92 Roofing Paper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.91 Tape– Masking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.95 Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.95 to 0.96 Wood– planed oak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.90 NONMETALSNOTES:6-3NOTES: 6-4OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. T his affords our customers the latest in technology and engineering.OMEGA is a trademark of OMEGA ENGINEERING, INC.© Copyright 2017 OMEGA ENGINEERING, INC. All rights reserved. T his document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:1. P urchase Order number under which the product was PURCHASED,2. M odel and serial number of the product under warranty, and3. Repair instructions and/or specific problems relative to the product.FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:1. Purchase Order number to cover the COST of the repair,2. Model and serial number of the product, and 3. Repair instructions and/or specific problems relative to the product.RETURN REQUESTS/INQUIRIESDirect all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RET URNING ANY PRODUCT (S) T O OMEGA, PURCHASER MUST OBT AIN AN AUT HORIZED RET URN (AR) NUMBER FROM OMEGA’S CUST OMER SERVICE DEPART MENT (IN ORDER T O AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.T he purchaser is responsible for shipping charges, freight, insurance and proper packaging to preventbreakage in transit.WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 25 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal two (2) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANT Y does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. T his WARRANT Y is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED W ARRANTIES INCLUDING ANY W ARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANT Y /DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of theProduct(s) in such a manner.Where Do I Find Everything I Need forProcess Measurement and Control?OMEGA…Of Course!Shop online at TEMPERATUREM U Thermocouple, RTD & Thermistor Probes, Connectors,Panels & AssembliesM U Wire: Thermocouple, RTD & ThermistorM U Calibrators & Ice Point ReferencesM U Recorders, Controllers & Process MonitorsM U Infrared PyrometersPRESSURE, STRAIN AND FORCEM U Transducers & Strain GagesM U Load Cells & Pressure GagesM U Displacement TransducersM U Instrumentation & AccessoriesFLOW/LEVELM U Rotameters, Gas Mass Flowmeters & Flow ComputersM U Air Velocity IndicatorsM U Turbine/Paddlewheel SystemsM U Totalizers & Batch ControllerspH/CONDUCTIVITYM U pH Electrodes, Testers & AccessoriesM U Benchtop/Laboratory MetersM U Controllers, Calibrators, Simulators & PumpsM U Industrial pH & Conductivity EquipmentDATA ACQUISITIONM U Communications-Based Acquisition SystemsM U Data Logging SystemsM U Wireless Sensors, Transmitters, & ReceiversM U Signal ConditionersM U Data Acquisition SoftwareHEATERSM U Heating CableM U Cartridge & Strip HeatersM U Immersion & Band HeatersM U Flexible HeatersM U Laboratory HeatersENVIRONMENTALMONITORING AND CONTROLM U Metering & Control InstrumentationM U RefractometersM U Pumps & TubingM U Air, Soil & Water MonitorsM U Industrial Water & Wastewater TreatmentM U pH, Conductivity & Dissolved Oxygen InstrumentsM3572/1217。

iec309

iec309

IEC309IntroductionIEC309 is a standard for industrial connectors and plugs developed by the International Electrotechnical Commission (IEC). These connectors are widely used in various industries, including power distribution, manufacturing, and data centers. In this document, we will discuss the features, applications, and benefits of IEC309 connectors.Features of IEC309 Connectors1. Robust ConstructionIEC309 connectors are designed to withstand harsh environments and heavy-duty applications. These connectors are built using high-quality materials such as thermoplastics and metals, ensuring durability and longevity. They can withstand high temperatures, humidity, dust, and vibrations.2. High Current Carrying CapacityOne of the key features of IEC309 connectors is their ability to handle high current loads. These connectors are available in various ampere ratings, typically ranging from 16A to 125A. They are capable of carrying heavy electricity loads without compromising on safety and performance.3. IP ratingsIEC309 connectors come with IP ratings, indicating their level of protection against dust and water. These connectors are available in different IP ratings, including IP44, IP54, and IP67. The higher the IP rating, the better the protection against environmental factors.4. Color-codedIEC309 connectors are color-coded to ensure proper identification of voltage levels. The color coding helps in preventing mismatched connections and reduces the risk of electrical accidents. For example, red connectors indicate high voltage, while blue connectors are used for low voltage applications.5. Safety FeaturesIEC309 connectors incorporate several safety features to protect against electrical hazards. These features include locking mechanisms to prevent accidental disconnections, grounding contacts for proper earthing, and insulation materials to prevent electrical shocks.Applications of IEC309 ConnectorsIEC309 connectors find applications in various industries and environments. Some of the common applications include:1. Power Distribution SystemsIEC309 connectors are commonly used in power distribution systems due to their high current carrying capacity. They are used for connecting generators, switchgear, transformers, and distribution panels. These connectors ensure safe and reliable power transmission in industrial settings.2. Data CentersData centers require robust and reliable power connections to support their critical operations. IEC309 connectors provide a secure and efficient solution for power distribution in data centers. They are used for connecting UPS systems, power distribution units (PDUs), and server racks.3. ManufacturingManufacturing facilities often have heavy machinery and equipment that require high power connections. IEC309 connectors are used to power industrial machines, motors, and control systems. These connectors ensure a stable and uninterrupted power supply for seamless manufacturing operations.4. Construction SitesConstruction sites often have demanding power requirements. IEC309 connectors are commonly used in construction sites to provide temporary power connections. These connectors can withstand rough handling, extremeweather conditions, and vibrations, making them suitable for the construction industry.Benefits of Using IEC309 Connectors1. SafetyIEC309 connectors are designed with safety in mind. The locking mechanism prevents accidental disconnections, reducing the risk of electrical shocks. The color-coding helps in identifying the correct voltage levels, reducing the chances of mismatched connections. Additionally, the IP ratings ensure protection against dust and water, making these connectors safe for use in various environments.2. VersatilityIEC309 connectors come in a wide range of configurations and ampere ratings, making them suitable for various applications. They can handle different voltage levels and current loads, providing flexibility in power distribution systems. The availability of different IP ratings also allows their use in different environmental conditions.3. ReliabilityWith their robust construction and high-quality materials, IEC309 connectors offer excellent reliability. They can withstand harsh conditions, heavy loads, and continuous usage without compromising their performance. These connectorsare built to last and provide reliable power connections in demanding industrial settings.4. CompatibilityIEC309 connectors are designed to be compatible with other standard connectors and plugs. This ensures seamless integration into existing power distribution systems. They can be easily connected to existing devices and equipment without the need for additional adapters or modifications.ConclusionIEC309 connectors are highly reliable, safe, and versatile industrial connectors that find applications in various industries. Their robust construction, high current carrying capacity, safety features, and compatibility make them an ideal choice for power distribution systems, data centers, manufacturing facilities, and construction sites. By usingIEC309 connectors, businesses can ensure a stable, efficient, and safe power supply essential for their operations.。

伟肯变频器用户手册

伟肯变频器用户手册

伟肯变频器用户手册安装和运行前,请务必遵照如下的起动和运行快速指南操作,并依次完成其中11个操作步骤。

如有任何问题,请与当地经销商联系。

快速指南1. 检查产品是否与定单相符,见第3章。

2. 进行任何调试前,请仔细阅读第1章中的安全规程。

3. 进行机械安装前,请根据第5章的说明检查外部环境条件和变频器周边的最小间距。

4. 按第6章的说明检查电机电缆、主电源电缆、主电源熔断器的规格和电缆的连接情况。

5. 根据第5章中的安装说明进行安装。

6. 根据§6.1.1中的说明检查控制电缆规格及接地系统。

7. 根据第7章中的说明使用控制面板。

8. 所有的参数都有工厂设定的缺省值。

为了确保正确运行,请检查下列电机铭牌数据和参数组P2.1中相应的参数设置。

见§8.3.2。

• 电机额定电压P2.1.6• 电机额定频率P2.1.7• 电机额定转速P2.1.8• 电机额定电流P2.1.9• 电机功率因数P2.1.10所有的参数说明见多目标控制应用手册。

9. 阅读第8章,按照调试步骤进行操作。

10. 至此,可以开始使用Vacon NXL变频器了。

11. 在本手册的结尾,您会看到有关默认I/O,控制面板菜单,监控值,故障代码和基本参数的快速帮助。

违反上述操作步骤所造成的任何损失,Vacon Plc概不负责。

目录VACON NXL用户手册目录1 安全指导2 EU认证3 收货4 技术数据5 安装6 电缆和接线7 控制面板8 调试9 故障跟踪10 选件卡OPT-AA的描述11 选件卡OPT-AI的描述VACON NXL多目标控制应用手册vacon • 3Vacon China电话: +86-10-51280006 传真: +86-10-65813733 24小时支持热线: +86-137******** Email :***************.cn关于VACON NXL 用户手册和多目标控制应用手册恭喜您选择了Vacon NXL 变频器所提供的平滑控制!用户手册将为您提供有关Vacon NXL 变频器的安装,调试和操作的必要信息。

乐维顿OSSMT多技术Decora壁挂感应器说明书

乐维顿OSSMT多技术Decora壁挂感应器说明书

UPC Code: ************ Country Of Origin:Mexico OSSMT-GDEMulti-Tech wall box occupancy sensor w/no neutral wire, 120/208/220/230/240/277v, 50/60Hz, CEC Title 20/24 Compliant, 30s-30m Time Delay, Ambient Light Override, Self Adjusting, Field Configurable, NAFTA Compliant. Color: BlackLeviton’s OSSMT Multi-Technology Decora Wall Switch Occupancy Sensor is used to provide automatic lighting control for energy savings and convenience in a variety of commercial applications.Technical InformationProduct FeaturesAdjustment: Self-AdjustingCode Compliance: California Title 24Color: BlackConsumption (mA): N/ACoverage (Sq.Ft.): 2400Device Type: Occupancy SensorGrade: CommercialHVAC Relay: N/ALED Color: Green and RedLoad Rating: 800W@120V INC1200VA@120V 2700VA@277V FLMotor: 1/4 HP @ 120VMounting: Wall SwitchMounting Height (Ft.): 4 Ft.Neutral Wire Connection: Not RequiredOperating Temperature: 0C to 50CPattern: 180°Photocell: InternalPower Pack: External Power Pack NotRequiredProduct Line: OSSMTRelative Humidity: 20% to 90% non-condensingSensor Type: Wall SwitchSize: 4.06" H x 1.75" W x 1.85" D(103.2mm x 44.4mm x 47.2mm)Standards and Certifications: UL/cULStorage Temperature Range: -10°C to85°CSwitch Type: Single-PoleTechnology: Multi-TechnologyPIR/UltrasonicTime Delay: 30s-30mVoltage: 120/277 VACWallplate: Order SeparatelyWarranty: 5-Year LimitedStandards and CertificationsNAFTA Compliant: YesTitle 24 Compliant: YesMechanical SpecificationsNeutral Wire Connection: Not RequiredSwitch Type: Single-PoleElectrical SpecificationsFrequency: 50/60HzVoltage: 120/277 VACFeatures and BenefitsFast, simple Installation: Fits in a standard wall box and replaces a single-pole wall-switch; neutral and no neutral options available. Sensor can be gangedtogether with other units in a multiple-switch wall plate.-Low-profile design eliminates obtrusive “scanning-device” look. Elegant Decora wallplates complement any interior for sleek aesthetics; uses Decora wallplates and coordinates with Leviton’s popular line of Decora wiring devices.-Convenient Pushbutton provides manual-ON/OFF light switching at any time.-Segmented Fresnel lens provides optimum sensitivity and performance.Designed with an extensive “minor motion” area where even slight bodymovements will be detected.-Vandal resistant PIR lens.-Adjustable horizontal field-of-view (PIR may be adjusted between 180° and 60°-of arc by using integral blinders located on either side of the lens). No masking required.-Manual-ON/auto-OFF mode for installations where manual-ON switching isrequired but auto-OFF switching is still desired for CEC Title 24 energy savings.-To comply with CED Title 24, LED indicator light flashes when sensor detectsmotion to verify detection is active. Green flashes for ultrasonic, red flashes for PIR.Time: The delayed OFF time is preset at 30 minutes in the Auto Adapting mode.-A choice of four delayed-OFF time settings are available: 30-seconds (forwalking test purposes only), 10, 20, and 30 minutes for fixed time and autoadapting. The LED will flash when the adjusting knob is set to the indicated time value.Ambient Light Recognition: Integrated light sensor prevents lights from turning on -when the room is adequately illuminated by natural light.Self-Adaptive Technology: Callbacks for adjustment are eliminated. Time delay -and sensitivity settings are continually adjusted to occupant patterns of use inauto adapt mode.Exclusive Walk-through Feature provides increased energy savings by not-leaving the lights ON for an extended period after only momentary occupancy.-Vacancy Confirmation: When the time out expires and the relays turn OFF, a 30 second (OSSMT-G) or 40 second (OSSMT-M) vacancy confirmation exists toturn the relays back on.-False detection circuitry.-Small Motion Sensitivity (U/S): Ultrasonic technology provides excellent minormotion sensitivity.-Ability to disable U/S (OSSMT-M). For added flexbility, OSSMT-G has the ability to disable both PIR and U/S.Presentation Mode feature: For slide or film presentations, allows pushbuttons to -turn lights OFF and keep them OFF while the room is occupied.-Exclusive Leviton H.I.S. Circuitry. Specifically designed to handle today’s highinrush electronic ballast loads and offer unmatched durability and service.True Zero-Cross Relay switches at the zero crossing point of the AC power curve -to ensure maximum contactor life and compatibility with electronic ballasts. Patents*US8502660MX303643US8115626*This list is provided for patent marking purposes only. A good faith effort is made to maintain the accuracy and completeness of this list. No legal inference should be drawn from the omission of a patent from this list.Leviton Manufacturing Co., Inc.201 North Service Road, Melville, NY 11747Telephone: +1-800-323-8920 · FAX: +1-800-832-9538 · Tech Line (8:30AM-7:30PM E.S.T. Monday-Friday): +1-800-824-3005Leviton Manufacturing of Canada, Ltd.165 Hymus Boulevard, Pointe Claire, Quebec H9R 1E9 · Telephone: +1-800-469-7890 ·FAX: +1-800-824-3005 · /canadaLeviton S. de R.L. de C.V.Lago Tana 43, Mexico DF, Mexico CP 11290 · Tel.: (+52)55-5082-1040 · FAX: (+52)5386-1797 · .mxVisit our Website at: © 2018 Leviton Manufacturing Co., Inc. All Rights Reserved. Subject to change without notice.Leviton has a global presence.If you would like to know where your local Leviton office is located please go to:/international/contacts/。

卡洛瓦梭工业A S PD30CTRR60BPxxIO IO-Link光电反射式传感器说明说明书

卡洛瓦梭工业A S PD30CTRR60BPxxIO IO-Link光电反射式传感器说明说明书

PD30CTRR60BPxxIO - IO-LinkPhotoelectric Retro-reflective sensors with IO-Link communicationDescriptionThe PD30CTRR60BPxxIO are a part of the latest generation of high performance photoelectric sensors designed to solve most detection tasks due to the new IO-Link features.The sensors are implemented in the compact 10 x 20 x 30 mm ABS housing that are acknoledged world wide.New implemented functions with weight on functionality, reliability, Predictive maintenance make these sensors ideal for Industry 4.0.Benefits• Retro-reflective sensor with IO-Link with a adjustable distance of 1.7 to 6 m, either by trimmer or via IO-Link.• Application functions: Pattern Recognition, Speed & Length, Divider function and Object & Gap Monitoring.• Neighbour Immunity , selectable up to 3 sensors• Easy customization to specific OEM requests by use of the build in IO-Link functionalities.• The output can be operated either as a standard switching output or in IO-Link mode.• Fully configurable via output IO-Link v 1.1. Electrical outputs can be configured as PNP / NPN / Push-Pull / External input, normally open or normally closed.• Timer functions can be set, such as ON-delay, Off-delay, and one shots.• Logging functions: Temperatures, detecting counter, power cycles and operating hours.• Detection modes Single point, two point and windows mode.• Logic functions: AND, OR, XOR and Gated SR-FF.• Analogue output: In IO-Link mode the sensor will generate 16 bit analogue process data output representing various selectable process data such as received signal level.• ApplicationsPattern Recognition : An easy way to verify that a product is manufactured to the specification e.g. Furniture production where tabs or holes has to be with a defined pattern.Speed and Length : Monitor the speed and length of an object on a conveyour for e.g. sorting on size.Divider function : A de-central counting function that gives a signal when a preset count level is reached e.g. when a certain items are packed in a carton box it ask for a new box.Object and Gap Monitoring : Function that can sort out good objects and gaps between them so e.g. a packaging machine only reveive objects with the correct size and gaps.Main functions• Detects presence or absence of objects that cut off the light from the emitter • Detects all opaque objects very reliably• The sensor can be operated in IO-Link mode once connected to an IO-Link master or in standard I/O mode.•Received light intensity as process data.• Neighbor inference protection.• Sensing distance by potentiometer, teach by wire or by IO-link parameter.• Quality of Run and Quality of Teach result.• Temperature date for preventive maintenance.• Front-end check for preventive maintenance.Adjustable parameters via IO-Link interface:• Sensing distance and hysteresis.• Sensing modes: single point or two point or window mode.• Timer functions, e.g.: On-delay, Off delay, One shot leading edge or trailing edge.• Logic functions such as: AND, OR, X-OR and SR-FF.• External input.• Logging functions: Maximum temperatures, minimum temperatures, operating hours, operating cycles, power cycles, minutes above maximum temperature, minutes below minimum temperature, etc.• Auto hysteresis• Special functions: Pattern Recognition, Speed & Length, Divider function and Object & Gap Monitoring. ReferencesProduct selection keyEnter the code option instead ofType selectionStructureCBDA EFCBDA EGFig. 1 CableFig. 2 PlugFig. 3"M8-plug" Pin numbersSensingDetectionApplication functionsPattern RecognitionSpeed and LengthDivider functionObject and Gap MonitoringAlarm settingsDetection diagram0.02.0393.9-2.0795.9-5.9-3.91181581972362763152000300010005000600070008000150400010050-50-100-1500ABCDAccuracyExcess gain0.0 0.4 3.9 39.4393.70.11101001101001000100000.1110100ABCFeaturesPower SupplyAuto adjustInput selectorLogic functionsTime delaysOutputsOperation diagramFor default factory sensor Tv = Power-ON delayResponse timesIndication*See operation diagramLED indicationEnvironmental1)Do not bend the cable in temperatures below-10°C2)With no icing or condensationEMCDiagnostic parametersEvents ConfigurationObservation menuProcess data structure4 Bytes, Analogue value 16 ... 31 (16 bit)Mechanics/electronicsConnectionWiringABHousingDimensionsCompatibility and conformity Approvals and markings(UL508) IO-LinkDelivery contents and accessoriesDelivery contents• Photoelectric switch: PD30CTRR60BPxxIO• Screwdriver• Packaging: Plastic bagAccessories• Mounting bracket: APD30-MB1 or APD30-MB2 to be purchased separately• Connector type: CO..54NF... series to be purchased separatelyFurther informationCOPYRIGHT ©2021Content subject to change. Download the PDF: 。

阿特拉斯枪样本

阿特拉斯枪样本

电动装配工具和系统
69
工具代码............................................................................. 70 产品安全............................................................................. 74 工业用电池螺丝刀............................................................... 75 电动螺丝刀 – Eliza, EBL..................................................... 84 电动螺丝刀 – 电动微扭螺丝刀MicroTorqueTM..................... 87 电动螺丝刀 – Tensor DL..................................................... 90 电动螺丝刀 – Tensor SL..................................................... 91 电动拧紧扳手 – Tensor DS................................................. 92 电动拧紧扳手 – Tensor S.................................................... 98 电动拧紧扳手 – Tensor ST............................................... 103 Tensor DS / DL控制器.......................................................111 Power Focus.................................................................... 112 Power Focus / ETX拧紧轴和电缆..................................... 130 Power MACS 4000 / QST拧紧轴和电缆........................... 133 Power MACS / QMX拧紧轴和电缆................................... 141 刀头和动力套筒................................................................ 149 扭力臂............................................................................... 156

YG-309操控装置带无线测温使用说明书

YG-309操控装置带无线测温使用说明书

版本号V3.01 免费升级三年质保快速交货现场报期开关柜智能操控装置产品说明书目录一、概述3二、功能简介3三、技术指标3四、操作简介41. 温湿度采集及控制 (4)2. 装置面板说明 (4)3. 语音防误功能 (6)4. SOE事件记录功能65. 人体感应功能66. 触头及电缆接头测温功能67. 操作菜单78. 传感器的安装89. 开孔尺寸及接线端子图 (8)10. 通讯功能 (9)五、运输和贮存15六、保修期限15一、概述该系列开关柜智能操控装置是一款新型多功能、模拟动态指示,带液晶显示的智能装置。

具有温度,凝露的测量及自动除湿降温,有动态一次模拟图,带电显示及闭锁、断路器分合状态指示、储能指示、接地开关状态指示、手车位置指示、分合闸回路完好指示、语音防止误操作提示、远方/就地操作、远程通信、柜内照明、SOE 事件记录、人体感应,还具有电气接点温度测量功能。

本产品采用单片机内核设计,中文操作菜单,与传统的指示仪相比,操作界面更友好,使用更简单,更性化。

适用于中置柜、手车柜、固定柜、环网柜等多种开关柜。

二、功能简介动态一次模拟图、温湿度测量及调节、带电显示及闭锁、报警输出接口、防误语音、RS485通讯、照明、储能、分合闸转换开关等功能。

本产品采用独特的抗干扰技术,抗干扰能力强。

三、技术指标• 供电电源:AC/DC85~265V• 工作环境:温度-30℃~+65℃相对湿度W90%RH 大气压强:W 2500pa • 功耗:W 5W• 抗电强度:外壳与端子间三AC2kV • 绝缘性能:外壳与端子间三100M Q • 动态模拟一次接线图• 模拟图(面膜)的制作:根据用户现场实际的一次接线方案、电压等级设计面膜。

•动态模拟对象:断路器,手车位置,接地开关、储能等,通过电路采样,动态地根据实际信息变化面膜上的一次接线图,从而实现动态模拟的目的。

模拟图显示如下:分闸(或回路)显示预分预合闸闪烁指示(选配) 储能显示 试验位置显示断路器、接地刀防误闪烁提示 • 温湿度测量及调节最多可测量及显示两路温湿度数据,且可实现对温湿度的自动调节。

传感与控制-槽型及标签检测传感器

传感与控制-槽型及标签检测传感器

SL30系列槽形传感器416SL30系列槽形传感器S L 30 S e r i e s电缆式接插件式* 暗态操作,将灰线接至+(棕)亮态操作,将灰线接至-(蓝)或开路5针Euro 型接插件(所示为接插件式电缆端) •Email: sensors@417SL30系列槽形传感器SL30 系列电缆式接插件式418SL30系列槽形传感器S L 30 S e r i e s电缆式接插件式SL30型SLE30专家型接插件式系列槽形传感器 •Email: sensors@421SL10系列槽形传感器SL10 系列电缆式接插件式* 暗态操作,将灰线接至+(棕)亮态操作,将灰线接至-(蓝)或开路5针Euro 型接插件(所示为接插件式电缆端)422SL10系列槽形传感器S L 10 S e r i e s电缆式接插件式C-GAGE®SLC1系列标签检测传感器• 采用自适应数字逻辑技术(ADL),无需用户调整,传感器自动进行示教• 连续自动调整门槛值,并进行补偿• 定位精度±0.3mm• 标签最大运行速度10m/s(33'/s)• 可靠检测底带上的多种标签- 不透明底带上的透明标签- 透明底带上的透明标签- 不透明底带上的不透明标签- 透明底带上的不透明标签• 外壳坚固,槽宽1mm(0.04")注:对于含金属成分或碳素墨水成分,以及凹凸明显或带金属基片的标签,不推荐使用此种传感器424C - GAGE ®®SL C1系列标签检测传感器S L C 1 S e r i e s对于SLC1传感器:i) 9m(30')电缆的型号通过在电缆型传感器的型号后添加后缀“W/30”加以识别(如SLC1BB6 W/30)ii) QD 型需要另配接插电缆* 标签间隙3.2mm(0.125"),纸带运行速度最大10m/s 。

对于系统的实际运行速度,我们主要考虑纸带的瞬间速度,而不是平均速度。

omega美国PX309_CH系列

omega美国PX309_CH系列

全不锈钢传感器PX319-100GVPX329-100GVPX309-100GV.电缆型。

微型扭锁式。

坚固耐用的通用传感器通用规格订购一个缓冲器保护您的压力传,图片为实际尺寸。

规格OMEGA 的PX309系列量程低于100 psi 的型号使用高精度硅传感器,该传感器受充油不锈钢膜片的保护。

100 psi 及以上量程装置使用以分子状固定在不锈钢膜片上的硅应变片。

长期稳定性(1年): ±0.25%(常规)常规寿命: 一千万次(常规)工作温度: -40 ~ 85°C (-40 ~ 185°F)耐受压力:全psia 及≤50 psig 量程:容量的3倍或20 psi ,以较大值为准 100 psig 量程: 容量的2倍破裂压力: 容量的500%或25 psi ,以较大值为准响应时间: <1 ms冲击: 50 g, 11 ms 半正弦波冲击 振动: ±20 g 保护等级: IP 65接液部件:全psia 及1 ~ 50 psig 量程为316不锈钢; 100 ~ 10,000 psig 量程为17-4 PH 不锈钢压力端口: 1⁄4-18 MNPT 电气连接:PX309: 1.5 m (5') 2芯、3芯或4芯电缆(分别为mA 、5V 及 mV 输出) PX319: 微型DIN 连接器 (含对接连接器)P X329: 扭锁式连接器,导气对接连接器单独销售(PT06V-10-6S) PX359: M12,4针连接器重量:PX309: 154 g (5.4 oz)PX319、PX329、PX359: 100 g (3.5 oz)100 mV 输出激励:0 ~ 50 psig 及全psia 量程:10 Vdc (比率式),(5 ~ 12 Vdc 范围内) 100 ~ 10,000 psig 量程:5 Vdc (ratiometric), (3 ~ 10 Vdc limits)输出: 0 ~ 100 mV ,例外情况2 psi = 40 mV ,1 psi = 20 mV精度: 25ºC 温度下为 ±0.25% FS BSL (包括线性度、滞后性及重复性)零点偏移: ±2% FSO ; 对1和2 psi 量程为±4%跨距设置: ±2% FSO ;对1和2 psi 量程为±4%补偿温度: 0 ~ 50°C (32 ~ 122°F )归零和跨距校正热效应(在补偿范围内):15 ~ 10,000 psi 量程: ±2% FSO 5 psi 量程: ±3% FSO 2 psi 量程: ±4% FSO 1 psi 量程: ±5% FSO5V 输出激励: 9 ~ 30 Vdc(反向极性和过压保护)输出: 0 ~ 5 Vdc 或 4 ~ 20 mA5 ~ 10,000 psi 的静态精度: 25ºC 温度下 为±0.25% FS BSL (包括线性度、滞后性及重复性)零点偏移: ±2% FSO; 对1和2 psi 量程为±4%跨距设置: ±2% FSO; 对1和2 psi 量程为±4% 补偿温度:>5 psi 量程: -20 ~ 85°C (-4 ~ 185°F) ≤5 psi 量程: 0 ~ 50°C (32 ~ 122°F)总误差范围: ±2% FSO ;包括线性度、滞后性、重复性、热滞后及热误差(例外情况:2 psi = ±3%,1 psi = ±4.5%)0-10,000 psi0-690 bar微型DIN式。

Techcon 309L-C 硬件安装

Techcon 309L-C 硬件安装

1. 产品描述Techcon 变风量VAV 控制器Techcon 309L-C 基于控制以下多种类型HVAC 设备而设计,如:基板,热风道,多级加热器和风机,冷却器,阀门,灯光等。

控制器基于LONWORKS ® 技术,在控制器和L ON M ARK ®认证的设备间对等(peer-to-peer )通讯。

本文档用于Techcon 309L-C 的硬件安装过程。

注意 查阅Techcon 309L-C 用户指南可获得更多该设备的使用信息。

图 1-1: Techcon 309L-C 控制器2. 安装条件为了Techcon 309L-C 控制器的正确安装和后续操作,需要特别注意以下建议:- 在拆开Technovator 产品包装前,请检查纸箱内容,以防运输损伤。

不要安装已损坏设备。

- 去掉设备保护性外罩,接线端子和服务插头(service pin )使其易于操作,硬件配置和保养。

不要忘记记录Neuron ID ,它位于设备的顶端(采用文本和条形码格式),为后续投入运行(commission )做准备。

- 控制器基于以下环境条件设计:环境温度:32°F to 158°F (0°C to 70°C)。

相对湿度: 0% to 95%, 无结露。

- 保证设备通风,避免处于以下环境:腐蚀性,恶劣条件,易爆气体,浓烟或有毒气体中。

• 安装前,需要确认本地通讯条例允许安装操作频率为868.3 MHz 的无线设备。

• 合理预防安装过程中,维护或操作设备过程中的静态放电。

在对此类设备工作之前,通过接触安全的接地设备把积聚的静电荷释放掉。

硬件安装指南专用VAV ( Variable Air Volume )控制器自由编程VAV ( Variable Air Volume )控制器Techcon 309L-C Techcon 309L-P13. 接线条件- 所有接线必须遵守国际和当地电气规程。

PX309系列高性能压力传感器说明书

PX309系列高性能压力传感器说明书

PX309-100GV PX309-005GI PX309-015CGI PX309-030AI PX309-V150G5V0-0.07 to 0-690 bar 100 mV, 0 to 5 V,and 4 to 20 mA OutputsPX309 SeriesU 1, 2 & 5 psi Low Pressure Ranges!U All Stainless Steel ConstructionU Gage, Absolute, Compound Gage or Vacuum PressureU Rugged Solid State DesignU High Stability, Low DriftU 0.25% Static AccuracyUIP65 Protection ClassWe provide a complete range of services—from product inception, through design and prototypes, to manufacturing and testing. Our application engineers work closely with our customers to customize , design or create entirely new products . Call us—whether you’re an OEM, manufacturer, or end user.PX319-100GVPX329-100GV All models shown smaller than actual size.PX309-100GV.Cable style.mini DIN style.Twist-lock style.t !PX359-100GV M12 connector style1Pressure Ranges!U All Stainless SteelConstructionU Gage or AbsolutePressureU Rugged Solid StateDesignU High Stability, Low DriftU 0.25% Static AccuracyU IP 65 ProtectionClassOMEGA’s PX309 Series modelsbelow 100 psi use a high-accuracy silicon sensor protectedby an oil-filled stainless steeldiaphragm. Units 100 psi andabove use silicon strain gagesmolecularly bonded to thestainless steel diaphragm.Ranges: -15 to 50 psig, 0 to 1000psia, 100 to 10,000 psigAccuracy (Combined Linearity,Hysteresis and Repeatability):±0.25% BSL, maxMinimum Resistance BetweenTransducer Body and Any Wire:1M Ω @ 25 VdcCalibration: In vertical direction withfitting downPressure Cycles: 10 million, minimumPressure Overload: -15 to 50 psigand 0 to 1000 psia: 3 times ratedpressure or 20 psi whicheveris greater, 100 to 10,000 psig:2 times rated pressureBurst Pressure: -15 to 50 psig and0 to 1000 psia: 4 times rated pressureor 25 psi whichever is greater, 100to 10,000 psig: 5 times rated pressureLong Term Stability (1 Year):±0.25% of FS, typicalOperating Temperature: -40 to 85°C(-40 to 185°F)Pressure Port:1⁄4-18 MNPTCE: CompliantShock: 50 g, 11 ms half-sineVibration: ±20 gResponse Time: <1 millisecondWeight:PX309: 154 g (5.4 oz),PX319/329/359: 100 g (3.5 oz)IP Rating: IP65RoHS: CompliantNotes: 1. Units 100 psig and above may be subjected to vacuum on the pressure port without damage. 2. For alternative performance specifications to suit your application, contact Engineering.Ordering Examples: PX309-100GV, 100 psi gage pressure transducer with 100 mV output at 5 Vdc excitation and 1.5 m cable termination. PX319-015AV, 15 psi absolute pressure transducer with 100 mV output @ 10 Vdc excitation and mini DIN termination. PX329-3KGV, 3000 psi gage pressure transducer with 100 mV output @ 5 Vdc excitationand twist-lock 6 pin connector termination. Mating connector sold separately, order PT06V-10-6S,Consult Sales for OEM pricing.100 mV Output Specifications (In Addition to Common Specifications on page 2)Setting Accuracy Zero and Span:±2% FS (±4% FS for 1 and 2 psi)Supply Voltage:-15 to 50 psig and 0 to 1000 psia: 10 Vdc, 100 to 10,000 psig: 5 Vdc typical1 to 5 Vdc Input Impedance: 4k to 13k ΩOutput Impedance: 4k to 6k ΩZero Shift:-15 to 50 psig and 0 to 1000 psia: ±0.03%/°C (0 to 5 psig/ psia is ±0.06%/°C, 0 to 2 psig is ±0.08%/°C, 0 to 1 psig is ±0.1%/°C). 100 to 10,000 psig: ±2% over compensated range ref 25°CSpan Shift:-15 to 50 psig and 0 to 1000 psia: ±0.03%/°C (0 to 5 psig/ psia is ±0.04%/°C, 0 to 2 psig is ±0.05%/°C, 0 to 1 psig is ±0.06%/°C). 100 to 10,000 psig: ±2% over compensated range ref 25°CCompensated Temperature:-15 to 50 psig and 0 to 1000 psia: 0 to 50°C, 100 to 10,000 psig: 0 to 55°CPX309 Series5V Output Specifications (In Addition to Common Specifications on page 2)Total Error Band (Includes Linearity, Hyesteresis, Repeatability, Thermal Hysteresis and Thermal Errors, Not Including Zero and Span Setting Accuracy): ±1.0%(5 psig/psia is ±1.5%, 2 psig is 3.0% and 1 psig is 4.5%)Supply Voltage: 9 to 30 Vdc,Supply Current < 10 mACompensated Temperature:-20 to 85°C (≤ 5 psig/psiais 0 to 50°C)*Notes: 1. Units 100 psig and above may be subjected to vacuum on the pressure port without damage. 2. For alternative performance specifications to suit your application, contact Engineering.Ordering Examples: PX309-100G5V, 100 psi gage pressure transducer with 0 to 5 Vdc output and 1.5 m cable termination. PX319-015A5V, 15 psi absolute pressure transducer with 0 to 5 Vdc output and mini DIN termination. PX329-3KG5V, 3000 psi gage pressure transducer with 0 to 5 Vdc output and twist-lock 6 pin connectortermination. Mating connector sold separately; order PT06V-10-6S. Consult Sales for OEM pricing.4 to 20 mA OutputSpecifications (In Addition to Common Specifications on page 2)Total Error Band (Includes Linearity, Hyesteresis, Repeatability, Thermal Hysteresis and Thermal Errors, Not Including Zero and Span Setting Accuracy):±1.0% (5 psig/psia is ±1.5%, 2 psig is 3.0% and 1 psig is 4.5%)Supply Voltage: 9 to 30 VdcCompensated Temperature:-20 to 85°C (≤ 5 psig/psia is 0 to 50°C)Reverse Polarity ProtectedOver Voltage ProtectionPX309 SeriesComes complete with 5-point NIST-traceable calibration.Notes: 1. Units 100 psig and above may be subjected to vacuum on the pressure port without damage. 2. For alternative performance specifications to suit your application, contact Engineering. Ordering Examples: PX309-100GI, 100 psi gage pressure transducer with 4 to 20 mA output and 1.5m cable termination. PX319-015AI, 15 psi absolute pressure transducer with 4 to 20 mA output and mini DIN termination. PX329-3KGI, 3000 psi gage pressure transducer with 4 to 20 mA output and twist-lock 6 pin connector termination. Mating connector sold separately; order PT06V-10-6S. Consult Sales for OEM pricing.AccessoriesCA-359-4PC22-2M cable, shown smallerthan actual size.DP8PT, shown smaller than actual siz e.Installation NotesPX309 Series All PX309 (gage and absolute) use a vented cable. Gage PX309 sensors up to 100 PSIG must be terminated in a clean dry area that is open to atmosphere for correct operation. All other sensors (> 100 psig and all psia ranges) must be terminated in a dry area but do not need to be vented to atmosphere. These cables should be sealed (e.g. RTV) to protect the sensor from moisture getting in to the sensor through the cable.PX319 Series All PX319 are vented through a hole in the connector and through the mating connector. A vented cable must be used for low pressure gage sensors up to 100 PSIG and must be terminated in a clean dry area that is open to atmosphere for correct operation. The gasket for the DIN mating connector has a special stiffener (included) between the mating surfaces and is used to maintain the IP65 rating (Spare Gaskets are Part number P002612). See vented cable assembly CA-319-4PC24-XXX-WP for gage pressure under 100 psi. All other PX319 sensors can use standard cable but must be terminated in a dry location or sealed to prevent water from getting into the cable/sensor. See cable assembly CA-319-4PC24-XXX for all other pressure ranges.PX329 SeriesAll PX329 are vented through Pin F of the twist-lock connector. Gage PX329 up to 100 PSIG must be vented for correct operation and must use the connector PT06V-10-6S which has no socket on pin F . Cables for these sensors must use a vented cable, be sealed at the back of the mating connector and be terminated in a dry clean area open to the atmosphere. See cable assembly CA-329-4PC24-XXX-WP for gage pressure under 100 psi. All other PX329 can use a the standard PT06F10-6S connector or cables (See cable assembly CA-329-4PC24-XXX).PX359 Series All PX359 are vented through a hole in the connector. Gage PX359 up to 100 psig must be vented for correct operation and must use the either the CA-359-4PC22-2M or CA-359-4PC22-5M or similar cable. They also must be terminated in a clean dry area open to the atmosphere. All other PX359 can use a standard M12 mating cable like the M12C-PVC-4-S-F-5.PX319-100GVPX309-100GV.PX329-100GVPX359-100GV All models shown smaller than actual size.PX309-100GV PX309-005GI PX309-015CGI PX309-030AI PX309-V150G5V。

NU-TECH_9按键触摸芯片TC309_中文手册_V1.3

NU-TECH_9按键触摸芯片TC309_中文手册_V1.3

TC Serial touch sensor
Page 6 of 8
TC309_中文手册_V1.3
额定值 *
工作温度 存储温度 电源电压 管脚最大电流 管脚电压 * 注意 超出额定值可能会导致芯片永久损坏
电气特性
TA = 25℃ 特性 工作电压 电流消耗
符号 Vcc Idd
上电稳定时间 Tini
条件
3KΩ RX3
VCC
RU1 RU2 RU3
SDA 15 SCL 14 INT 13
10KΩ 10KΩ 10KΩ
SEN 3
20pf CSEN
CX8 12
RX8 3KΩ
CX7 11
RX7 3KΩ
CX6 10
RX6 3KΩ
CX5 9
RX5 3KΩ
CX4 8
RX4 3KΩ
MCU
PAD8 PAD7 PAD6 PAD5 PAD4
0.224
0.236
0.248
0.018
0.026
0.033

--

TC Serial touch sensor
Page 8 of 8
6.30
0.45
0.65
0.85

--

Dimensions In Inches
Min
Nom
Max
0.051
0.059
0.067
0.002
0.006
0.010
0.012
0.016
0.022
0.006
0.010
0.014
0.382
0.394
0.406
.0148
0.156

tgs2619工作原理

tgs2619工作原理

tgs2619工作原理
TGS2619是一种气体传感器,主要用于检测可燃气体和挥发性
有机化合物(VOCs)。

它的工作原理基于半导体气体传感技术。

该传感器使用了金属氧化物半导体(MOS)技术。

当目标气体进
入传感器时,它会与传感器的敏感层发生化学反应。

这种化学反应
会导致传感器的电阻发生变化。

传感器内置的电路会测量这种电阻
的变化,并将其转换为相应的电信号输出。

TGS2619的敏感层通常是由锡氧化物(SnO2)制成,这使得传
感器对可燃气体和VOCs具有高灵敏度。

当目标气体浓度增加时,敏
感层的电阻会相应增加或减小,从而产生不同的电信号输出。

传感器的工作原理可以通过测量电阻变化来检测目标气体的浓度。

这种工作原理使得TGS2619能够快速、准确地检测可燃气体和VOCs,使其在工业安全、环境监测等领域得到广泛应用。

总的来说,TGS2619的工作原理基于金属氧化物半导体技术,
通过测量敏感层电阻的变化来检测目标气体的浓度,具有灵敏度高、响应快的特点。

希望这个回答能够全面回答你的问题。

C2-309声音传感器

C2-309声音传感器

13.2 mm
13.2 mm
13.2 mm
高度 (带防护网) 16.2 mm
16.2 mm
12.7 mm
16.3 mm
重量
9 gm
9 gm
9 gm
9 gm
前置放大器接 11.7mm-60UNS 11.7mm-60UNS 11.7mm-60UNS 11.7mm-60UNS 头
简单介绍: 低成本ICP传 声器
制造商 Vernier Software & Technology
13979 S.W. Millikan Way Beaverton, Oregon 97005-2886
USA
技术指标
频率范围:大约20 Hz到16,000 Hz,但请注意:数据采集范围 的最大值受到数据采集器的频 率范围的影响。对于LabPro来 说,最大为5,000 Hz。
化) 6.9 mm 10.5 mm
2 gm 5.7mm60UNS
377A02 1/2英寸 自由场
50 m V/Pa 3.15—20k
Hz
148 dB
14.5 dB (A)
-40-+150℃ 0 V (预极
化)
13.2 mm
16.2 mm
7 gm
11.7mm60UNS
377A03 1/2英寸 自由场 50 m V/Pa 6.5—12.5k
148 dB
148 dB
160 dB
146 dB
本底噪声
16 dB
16 dB
20 dB (A)
15 dB (A)
工作温度范围 -40--+150℃
-40--+150℃
-40--+150℃

可盾连接器 OSV 光学传感器阀门系统说明书

可盾连接器 OSV 光学传感器阀门系统说明书

MODEL OSV OPTICAL SENSOR VALVEPhOTO-EYE ACCumuLATION SYSTEmopticalsensor and valve combination for conveyor automation. This unit is designed for sensing objects moving through conveyor zones in order to maximize product flow while preventing product damage. By incorporating solid-state electronics and a low wattage solenoid valve, the OSV uses logic and manual inputs to reliably control a pneumatic actuator. The actuator either extends or retracts, controlling the movement of the conveyor zone. Features include adjustable sensitivity and output delay with LEDs to facilitate troubleshooting and a visual display of sensor modes. These LEDs indicate power status, beam alignment, beam clear, object detected, valve output, and slug mode. The modular design allows easy component replacement . The OSV is a reliable alternative to expensive, high-maintenance, pneumatic accumulation zones.Consult factory for available versions listed by Canadian Standards Association for use with certified electrical equipment.*WARNING -When using metal fittings do not exceed 40 in. lbs. torque or material failure can occurInletOutletRetro-Reflective Green - Ready Red - Blocked Amber - Zone OffBRN (+)BLU (-)BLK (SLUG SIGNAL)(-)(+)• Sensing distances up to 6 ft. (retro-reflective)• Detection of a wide variety of materials • Cascadable up to 100 units• Adjustable (0.02 - 3 sec) valve time delay (retro-reflective)• Adjustable sensitivity• multi-color intelligent indicators fordiagnostics / status • Infrared light technology • Optional wire lengths• Supply Current: 65mA with 0.9W coil energized • Slug Signal (input): 12µA max. per sensor sinking(NPN) (retro-reflective)• Beam Signal (input): 5mA max. sourcing (PNP) (diffused)• Beam Signal (output): 200mA max. sinking (NPN)• Valve Orifice / Pressure: 1.0mm / 0 - 30 psi • Valve Type: Normally Closed • Operating Temperature: -10 to 50° C*Beam Status Signal follows the pattern as the Beam itself. When the Beam is clear the Beam Status Signal is ON.Retro-Reflective Accumulation Normally Open Operation When Beam is CLEAR (no object detected) 1) Status LED is GREEN 2) Valve is OPEN 3) Beam Signal is ON (sinking 200mA max) When Beam is BLOCKED (object detected) 1) Status LED turn RED for the set amount of time delay (0.02 - 3sec) then turns AmBER 2) Valve CLOSES after the set time delay 3) Beam Signal turns off immediately (no time delay) 4) If an override is needed, a GND signal to the Slug Input will OPEN all valves connected inline Normally Closed OperationWhen Beam is CLEAR (no object detected) 1) Status LED is GREEN 2) Valve is CLOSED3) Beam Signal is ON (sinking 200mA max) When Beam is BLOCKED (object detected)1) Status LED turn RED for the set amount of time delay (0.02 - 3sec) then turns AmBER2) Valve OPENS after the set time delay3) Beam Signal turns off immediately (no time delay)4) If an override is needed, a GND signal to the Slug Input willCLOSE all valves connected inlineRetro-Reflective AccumulationDiffused Accumulation (no time delay or slug)Diffused Accumulation Normally Open Operation When Beam is CLEAR (no object detected) 1) Status LED is AmBER 2) Valve is OPEN 3) Beam Signal is ON (sinking 200mA max) When Beam is BLOCKED (object detected) 1) Status LED is GREEN (no time delay) 2) Valve is CLOSED (no time delay) 3) Beam Signal turns off immediately (no time delay) Normally Closed OperationWhen Beam is CLEAR (no object detected) 1) Status LED is AmBER 2) Valve is CLOSED3) Beam Signal is ON (sinking 200mA max) When Beam is BLOCKED (object detected) 1) Status LED is GREEN (no time delay) 2) Valve is OPEN (no time delay)3) Beam Signal turns off immediately (no time delay)ONOrdering Example:OSV10-11110010Retro-reflective, accumulation,2 ft. zone length, without valveO S V - 1 1 1 0 1 0OSV male Patch Cord AccessoryWOSV10-910Retro Reflector - OSVR10-002available, consult factory.Retro-Reflective Indexing Normally Closed Operation Downstream Sensor Beam is CLEAR (no object detected) 1) Downstream Sensor Status LED is GREEN 2) Downstream Sensor valve is CLOSED 3) Downstream Sensor Beam Signal is LOW providing a CLEAR signal to the upstream sensor 4) upstream Sensor valve is CLOSED no matter if its beam is CLEAR of BLOCKED Downstream Sensor Beam is BLOCKED (object detected) 1) Downstream Sensor Status LED turns RED for the set time delay (0.02 - 3sec) then turns AmBER 2. Downstream Sensor valve OPENS after the set time delay 3) Downstream Sensor Beam Signal immediately changeshIGh (no time delay), providing a BLOCKED signal to the upstream Sensor 4) upstream Sensor valve is CLOSED until its Beam is BLOCKED 5) If both Downstream and upstream sensors are BLOCKED their valves will be OPEN 6) If an override is needed, a GND signal to the Slug Input will CLOSE all valves connected inlineRetro-Reflective Indexing Normally ClosedDiffused Indexing Normally Closed Operation Downstream Sensor Beam is CLEAR (no object detected) 1) Downstream Sensor status LED is AmBER 2) Downstream Sensor valve is CLOSED 3) Downstream Sensor Beam Signal is LOW, providing a CLEAR signal to the upstream sensor 4) upstream Sensor valve is CLOSED no matter if its beam is CLEAR of BLOCKED Downstream Sensor Beam is BLOCKED (object detected) 1) Downstream Sensor Status LED turns GREEN (no time delay) 2) Downstream Sensor valve OPENS (no time delay) 3) Downstream Sensor Beam Signal immediately changes hIGh (no time delay), providing a BLOCKED signal to the upstream Sensor 4) upstream Sensor valve is CLOSED until its Beam is BLOCKED 5) If both Downstream and upstream sensors are BLOCKED their valves will be OPEN 6) To release the LAST Downstream sensor, apply a 24VDC signal to the Beam Signal Input wire. (This only releasesthe last downstream sensor, no other sensors are affected)Diffused Indexing Normally Closed(no time delay or slug)。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

Techcon T309S
Techcon 网络型液晶显示传感器和VAV 平衡工具
应用
- 监测房间/外面温度 - 调整设定值
- 初始设定值手动超驰 - VAV 风量平衡工具
- 固定安装或连接标准房间传感器作为手持式风量平衡工具
特点
控制器兼容性
- T309 S 是为了和Techcon 309L -C 线路控制器工作而设计 - 使用串行通讯协议直接发送数据到相关的控制器的SMRT 输入端
- 能暂时用于无线型控制器的风量平衡应用
- 硬件
- 电源和通讯均采用2线制接口,可以使用现有的传感器配线。

- 双行 (每行 8个字符) 的 LCD 显示。

- 强健的 ABS 树脂,吸引人的包装设计。

- 在板式LON 插座上 (用法需要另外 2 个电线)。

-
超驰强制按钮。

界面外观
占有者能进入各种不同的用户模式功能:
-查看空间温度 -查看/调整设定值 -查看占有状态
-查看室外空气温度 -显示停机状态 先进的密码保护设置模式:
- VAV 平衡 (热/寒/混合风道气流控制) - 发送Service PIN 信息 - 转换温度单位 (°C/°F)
- 选择 VAV 或者 VVT 控制模式 - 查看 Techcon 309L -C 输入输出值
便携式使用
可临时接入传感器通讯接口或通过线缆直接接入VAV,作为便携式平衡工具使用。

T309S 专门设计与 Technovator'sTechcon 309L-C 系列控制器
连接。

该设备提供精密本地温度测知,并为房间占有者提供多种公共功能,也能为技术人员提供多种密码保护设置功能。

占有者接触到的是一个友好的用户界面,尽可能方便他们查看、调节到喜好的环境设置。

建筑物占有者也可以查看占有状态, 空间温度, 室外温度并且调整设定值。

维护人员可以进入密码保护配置模式,以便于他们完成VAV 联机风量平衡、发送Service PIN 信息、℃和℉温度单位转换、查看所有到 Techcon 309L -C 的输入和输出数值。

T309 S 可以固定安装在墙壁上或者当做可以接入标准墙装室内传感器的手持风量平衡工具使用。

把T309S 作为便携工具,技术人员能直接地运行详细的监测和 VAV 的配置 (也就是平衡) 和辅助设备, 正确地靠近那点控制。

轻巧的设计和快接 2 线接口使得这个装置非常方便使用。

现代, 光洁的外观设计适合教室、酒店、主管区域、办公室空间和商业的区域的应用。

设备随机提供一个可分离的安装背板,可安装在干爽的墙面上或安在2"x4"电气接线盒内。

Techcon 产品建立在严格的质量标准之上,提供一年产品质保。

产品尺寸和相关产品
常规
通讯
CPU : PIC16C622 电源: 外部电源 - 12 VDC LCD 显示: 2 线, 8 特性
2400个波连续传输超过 2 线的界面
不完全双方, 8-比特, 没有奇偶, 1个停止比特。

.
依据 EIA -232协议.
配线: 50 尺最大。

(15 公尺最大.),22个美国线规无遮蔽式,一双弯曲的标准电缆。

环境
常规
操作温度 0o
C to 70o
C, 32o
F to 158o
F 传感器
10K NTC 电热调节器
存储温度 -20o C to 70o C, -4o F to 158o F 范围 0o C to 70o C; 32 o F to 158o F
相对湿度
0 to 90%无冷凝 精度: ±0.2 o F, ±0.36 o F
分辨率: 0.1o C; 0.18 o F 电磁兼容电磁兼容
外壳
CE
CEI-61000-4-3:1995 材料 ABS resin
CEI-61000-4-6:1996 颜色
Off white
CEI-61000-4-2:1995 外形尺寸
4.94” x 3.38” x 1.28” CEI-61000-4-4:1995
(124 x 85 x 32.5 mm) 认证
重量
0.4 lbs (0.18 kg)
UL Listed (CDN & US) UL-873 温度指示和调节设备
(未决定的)
FCC FCC part 15, subpart B, class B 材料
UL94-V0
其他外围设备
除了 同方泰德 的 Techcon 产品线之外, 我们希望您优先选用我们的提供的其他配套外围设备。

相信的我们提供的外围设备能够帮助您: - 方便您的订货流程
- 各项内容以相同或更好的价格供货,简化您的寻价工作
- 通过提供质量与性能经过验证的产品,帮忙你建立标准化采购流程
请联系同方泰德国际科技(北京)有限公司销售部门以获得完整的产品和外设清单。

上述技术参数及外观可能在未通知的情况下改变。

Techcon 是同方泰德国际科技(北京)有限公司的商标。

L ON W ORKS , L ON M ARK , LonTalk, LNS 和 LON 是 Echelon 公司注册的商标。

相关产品
Techcon 应用 特性 VAV
Techcon 309L-C
T309 S 设计用来促进平衡的 VAV 。

显示所有的 Techcon 309L 的输入和输出值。

相关文档
最新文档