PP13-03-GAD-MS-WP-001-RB(AG raw water storage tank)

合集下载

沃茨 M 系列反渗透处理器带内置预处理和膜冲洗 适用型号:M-450 M-1000 M-2400 M

沃茨 M 系列反渗透处理器带内置预处理和膜冲洗 适用型号:M-450 M-1000 M-2400 M

M Series Reverse Osmosis ProcessorWith Built-in Pre-treatment and Membrane FlushFor Models:M- 450M-1000M-2400M-4800M-9600Installation, Operation&Maintenance ManualBefore installing and/or operating Watts M-Series Reverse Osmosis system, read this manual completely. Keep this manual available for future reference. Further information is available by contacting your local Watts distributor. Phone: (623)505-1511Pressure TankAtmospheric TankTABLE OF CONTENTSSpecifications Specifications Chart (4)InstallationMembrane installation (5)Inlet Connection (6)Permeate Line Connection (7)Pressure Tank Connection (8)Atmospheric Storage Tank (9)Plumb to Drain (10)OperationStart Up (11)Alarms (12)MaintenanceQuarterly Maintenance (13)Annual Maintenance (14)WarrantyWarranty (15)Glossary of Terms (17)Specifications Complete System PackagesSPECIFICATIONS M-450 M-1000 M-2400 M-4800 M-9600 DRY WEIGHT lbs. 300 310 350 650 750 WET WEIGHT lbs 550 1700 1750 4000 4100 FEED WATERCOLD/Temp ½”/35°-70° ½”/35°-70° ½”/35°-70° ¾”/35°-70° ¾”/35°-70° HOT/ Temp ½”/70°-140° ½”/70°-140° ½”/70°-140° ¾”/70°-140° ¾”/70°-140° FLOW RATE 2 GPM 4 GPM 8 GPM 12 GPM 24 GPM MAX.HARDNESS 17 Grains 17 Grains 17 Grains 17 Grains 17 Grains MAX. TDS 2500 PPM 2500 PPM 2500 PPM 2500 PPM 2500 PPM MAX. IRON 0.1 MGL 0.1 MGL 0.1 MGL 0.1 MGL 0.1 MGL MAX. PSIG 80 80 80 80 80 MIM. PSIG 25 25 25 25 25 DRAINCONNECTIONFLOOR SINK MIM.w/in 10 ft ofprocessor1/ ¼” 1/ ¼” 1/ ¼” 1/ ¼” 1/ ¼”ELECTRICALREQUIRMENTS VOLTS/AMPS VOLTS/AMPS VOLTS/AMPS VOLTS/AMPS VOLTS/AMPSRO PROCESSOR OPTIONAL 220V 115/7.2 115/7.2 115/11.0220/8.8115/23220/11.5220/11.5DELIVERY PUMP N/A 115/8.8 115/12.4 115/12.4 115/12.4 KDF FILTER N/A N/A N/A 115/2 115/2Membrane InstallationMembraneROFEED WATER MIN/MAX PSIGPIPE SIZE FLOW RATE M-450 25/80 psig ½” 2 GPM M-100 25/80 psig ½” 4 GPM M-240025/80 psig ½” 8 GPMM-4800 25/80 psig 1” 12 GPM M-960025/80 psig 1 ¼”24 GPMInlet ConnectionRequired fittings for Bulkhead & Tank M450 ½” MPT x 3/8C . M1000 ½” MPT x 3/8C M2400 ½” MPT x ½”CM4800 ¾” MPT x ¾” Female Slip Schedule 40 PVC M9600 1” MPT x 1” Female Slip Schedule 40 PVCBall Valve used with Pressure Tank applications.Note: Fittings are included with systems ordered as complete packages only!Permeate Line ConnectionM-450 – M2400½” Tubing or PVC pipe M4800 – M9600 ¾” PVC Schedule 40 pipePressure Tank ConnectionRecommended tubing sizeFrom bulkhead on unit to tank .Note: Fittings are included with Systems ordered as complete packages only!Note: Copper pipe is UNSUITABLE for any plumbing from RO Storage Tank!Recommended materials include: Braided Stainless Steel Tubing, Hard Stainless. Schedule 80 PVC or Poly Propylene is acceptable, if not being connected to boiler or heating system.M-4503/8” M-1000 3/8” M-2400 3/8”M-4800 ¾” M-9600¾”Atmospheric Storage TankBulkhead & Fitting SystemsNote: Copper pipe is UNSUITABLE for any plumbing from RO Storage tank! Recommended materials include: Braided Stainless Steel Tubing, Hard Stainless. Schedule 80 PVC or Poly Propylene, if not being connected to boiler or heating system.M-450 3/8” M-1000 3/8” M-2400 3/8” M-4800 3/4 “ M-96003/4”If the M-Series was ordered with the atmospheric storage tank, the three tank float switches have been installed at the factory. Check to insure the tank floats have not been damaged. 1. Connect the gray electrical cable containing four (4) wires from the M-Series control box to the corresponding electrical connection on the atmospheric tank.Plumb to DrainM-450M-1000M-2400M-4800M-9600Bulkhead Connection 1/2” Poly1/2” Poly1/2” Poly½” PVC¾” PVCDrain Size Min.1 ¼” 1 ¼” 1 ¼’ 1 ¼’ 1 ¼”Start Upü Ensure power switch (located on top of control Box). (#1) is in the OFF position.ü Plug the unit into an appropriate power supply.ü If installing a pressure Tank system, open the BallValve (#2) on the Bulkhead.ü Turn the Blending Valve to coldest setting [90°]. (#3) ü Fully open the Concentrate Needle (#4) Valve by turning it counter clockwise.ü Fully close Recirculate Needle Valve (#5) by turning it clockwise.ü Turn the incoming water supply on the RO processor to the “ON” position.ü Turn the Power Switch (#1) to “ON” position. • The Water inlet solenoid valve will open.• There will be a 5 second delay before the pump starts.• The system may cycle on and off automatically during initial start up as air is purged from system.• Allow the unit to run for 5 minutes while excess air is being purged from system.ü Close the Concentrate Needle Valve (#4) until the Feed Pressure Gauge(#6) reaches a max. of 150 psig. ü Open the Recirculation Needle Valve (#5) until the unit Feed Pressure Gauge (#6) drops to 140 psig.ü Close the Concentrate Needle Valve (#4) until 150 psig is again achieved on the Pump Feed Pressure Gauge (#6).Repeat underlined sequence until both flow meters read equal flows and feed pressure gauge reads 150 psi. At this point the RO processor is operating at its maximum efficiency potential.If using a Pressure Tank, system will continue to operate until Tank Pressure Gauge reads 60 psig or Float Tank, upper float switch is triggered by the water level.674105ALARMSM-Series processors are equipped with audible alarms.1. The Constant Tone signals lack of incoming water pressure.(-------------------------------------------------------- Constant Tone)•Check incoming feed pressure to ensure a minimum of 20 psi.•Water pressure below 20 psi will trigger alarm. Incoming feed waterpressure must be raised.2. One second intermittent beeping signals systems is in Auto –Bypass.(-- -- -- -- -- -- -- -- -- -- -- -- -- -- One second intermittent tone).•During initial start up with empty tank, the system will automatically be inAuto-Bypass until the tank has completely filled. The Auto by pass will only betriggered if the tank pressure drops below 5 psi (Pressure tank systems). Floatswitch controlled Atmospheric tank systems with float switches, remain on untiltank is full and processor has turned off automatically.3. Two second intermittent beeping indicates possible wiring problem orproblem with installation of Float Switches.(---- ---- ---- ---- ---- ---- Two second intermittent tone.)Solution:•Check to ensure labeledelectrical cables are connectedto corresponding floatswitches.•Check conductivity of wire toensure no broken wire cablesexist.•Verify Float position perdrawing to the right.MaintenanceQuarterly Preventive Maintenance for Systems with complete Pre and Post treatment.The M-Series RO processor requires quarterly preventive maintenanceconsisting of replacing (3) pre-filters and postFilters if supplied.1. Pre-filters are located on left side of ROprocessor.5. Unplug unit from Power Supply.6. Place bucket under pre-filters to catch the waterfrom the filter housings.7. Using supplied filter wrench, loosen filter housingstarting on the left.8. Replace with new 5 micron Sediment Filter and replace filterhousing using wrench to tighten securely.(O-rings and Bowls need to be lubricated with a watersoluble lubricant such as KY Jelly).9. Follow the above sequence with remaining filters.and Post Filters if supplied.10. Replace Calcite Feeder located on right hand side of unit usingsupplied filter housing wrench.(Calcite feeder is only needed on units feeding boilers).Follow “START UP” procedures on page 11Annual Preventive MaintenanceNote: If using pliers to remove NEW membrane for any reason, protect end of membrane with cloth, to prevent teeth marks which could result in leaks.Annual Preventive MaintenanceWARRANTYWHAT YOUR WARRANTY COVERS:If any part of your Premier Water Treatment Device is defective in workmanship (excluding replacement filter elements), return the unit within 1 year of date of original purchase. PREMIER will repair or, at PREMIER’S option, replace it at no charge.HOW TO OBTAIN WARRANTY SERVICE:Contact WATTS PREMIER’S customer service department (1-800-752-5582) to obtain a Return Goods Authorization Number (RGA#). Model and Serial Number are required for obtaining an RGA #. For warranty service, ship your water treatment device wit h the RGA # printed on the Shipping Label to PREMIER, freight and insurance prepaid, with proof of original purchase date. PREMIER will repair or replace the water treatment device and ship it back to you prepaid.WHAT YOUR WARRANTY DOES NOT COVER:This warranty does not cover defects resulting from improper installation, customer abuse, misuse, misapplication, improper maintenance, neglect, alteration, accidents, casualties, fire, flood, freezing, heat, environmental factors or acts of nature.This warranty will be voided if defects occur due to failure to observe the following conditions:1. The water treatment device must be hooked up to a potable municipal water supply.2. The pH of incoming water must not be lower than 6.0 or higher than 8.5.3. The incoming water pressure must be between 25 psi and 80 psi. If water pressure exceeds 80 psi a pressure regulator must be installed.4. Incoming water temperature cannot exceed 100° F (40° C).This warranty does not cover any equipment that has been relocated from the site of its original installation.This warranty does not cover equipment that is installed outside North America.LIMITATIONS AND EXCLUSIONS:PREMIER WILL NOT BE RESPONSIBLE FOR ANY IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.PREMIER WILL NOT BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING TRAVEL EXPENSES, TELEPHONE CHARGES, LOSS OF REVENUE, LOSS OF TIME, INCONVENIENCE, LOSS OF USE OF THE EQUIPMENT, AND DAMAGES CAUSED BY THE EQUIPMENT AND ITS FAILURE TO FUCTION PROPERLY.THIS WARRANTY SETS FORTH ALL OF PREMIER’S RESPONSIBILITIES REGARDING THIS EQUIPMENT.OTHER CONDITIONS: IF PREMIER chooses to replace the equipment, PREMIER may replace it with reconditi o ned equipment. Parts used in repairing or replacing the equipment will be warranted for 90 days from the date the equipment is returned to you or for the remainder of the original warranty period, whichever is longer. This warranty is not assignable or transferable.YOUR RIGHTS UNDER STATE LAW:Some states do not allow limitations on how long an implied warranty lasts and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights. You may have other legal rights, which vary from state to state.GLOSSARY OF TERMSAtmospheric tank: A storage container requiring additional delivery system to distribute stored water.Typically constructed of polyurethane or stainless steel. Used in situations where greater storagecapacity is needed than offered by conventional pressure tanks.Auto By-Pass: A feature that allows tap water to be delivered to downstream demands in the event the RO processor is unable to meet demand.Brine Seal: A black “O-ring type seal located on one end of membrane that seals the membrane to the vessel preventing cross contamination of process water and feed-water.Calcite Feeder: Calcite is a naturally occurring mineral used to raise the Total Dissolved Solids (TDS) in the water to promote conductivity in the final product water. Used in situations where conductivity isneeded for proper equipment function i.e. conductivity probes.Carbon Block: Acid washed carbon is used to absorb VOC’s (Volatile Organic Chemicals) such as herbicides, pesticides and chlorine, which will damage RO membranes.Concentrate needle valve: A needle valve located on the right side flow meter that controls the concentrate (drain water) water flow to the drain.Concentrate: Water being rinsed to drain after it has been rejected by the membrane.Concentrate Line: Tubing or pipe used to transport concentrated waste water to a suitable drain.Feed pressure: Referring to the water pressure being supplied to the RO processor before it has entered the pre-filter. Raw water.Feed pressure gauge: The upper most gauge on the control panel that indicates the water pressure the membrane is receiving.Flow meter: A meter that reads water flow in gallons/liters per minuteGPM: Gallons per minuteGPD: Gallons per dayHardness: Total quantity of CaCO3 (Calcium/magnesium) present in water.1 gr. = 17.1 TDS in ppm per U.S. gallonIron: A naturally occurring mineral that has detrimental effects on a membranes ability to produce water.Reduced by ion exchange (water softening) or KDF media.KDF Media Filter: A proprietary blend of metals and other substances that help reduce Iron and CaC03 (hardness). Used as pretreatment on some models of high production RO systems.L Copper pipe: A high grade of copper pipe that will withstand water temperatures up to 160 degrees Fahrenheit.Membrane: A thin sheet or surface film, either natural or man-made, of microporus structure that performs as an efficient filter of particles down to the size rang of chemical molecules and ions. Such membranes are termed “semi-permeable” because some substances will pass through but others will not. Usually small ions, water, solvents, gases, and other very small molecules can pass through a membrane, but other ions and macromolecules such as proteins and colloids are barred form passage. Membranes are used in reverse osmosis.GLOSSARY OF TERMS (Continued)Permeate: That portion of the feed water which passes through the membrane to become product water. Permeate Line: Tubing or pipe used to transport purified (RO processed) water from processor to the storage tank.Pressure tank: A water storage device using a pressurized bladder that provides delivery pressure to down stream uses.Purge: The act of flushing out. A term to describe the purging of entrained air in a systemRecirculation Valve: A needle control valve used to blend concentrate water past the membrane again to scavenge water molecules.Recirculation Ratio: The ratio in which concentrate water is reticulated past the membrane in order to osmoisize more water molecules and reduce the wasted ratio of water. Typical recirculation ratio is 1:1(1 gallon permeate: 1 gallon concentrateReverse Osmosis: A water treatment process that removes undesirable material from water by using pressure to force the water molecules through a semi-permeable membrane. This process is called“reverse” osmosis because the pressure forces the water to flow in the reveres direction (from theconcentrated solution to the dilute solution) to the flow direction (from the dilute to the concentrated) in the process of natural osmosis. RO removes ionized salts, colloids, and organic molecules down to a molecular weigh of 100. May be called hyper-filtration.RO: Reverse OsmosisRO Processor: The system main stand, that consists of the main frame, pump, electrical controls, flow meters and pressure gauges. A term used to signify a specific piece of the overall system.Sediment Filter: A filter used to trap and reduce rust, dirt and sand. Typically made from spun poly.TDS: Total Dissolved Solids, the total weight of dissolved matter present in water that does not constitute pure water molecules. Measured in the form of resistively and or conductivity equated into TDS in ppm(parts per million per 1 U.S. gallon)VOC: Volatile Organic Chemicals, synthetic organic chemicals that turn into vapor at relativelyZero Soft Water: Water produced by Reverse Osmosis measuring less than 1/0 grain per U.S. gallon (17.1 ppm or 17.1 mg/L) as calcium carbonate.。

莫莎公司 OnCell G2111 G2151I 系列工业四频GSM GPRS模块产品简介说明书

莫莎公司 OnCell G2111 G2151I 系列工业四频GSM GPRS模块产品简介说明书

OnCell G2111/G2151I SeriesIndustrial quad-band GSM/GPRS modemsFeatures and Benefits•Quad-band GSM/GPRS850/900/1800/1900MHz•DIN-rail mounting and wall mounting•2.5kV RMS isolation for1min.for all serial signals(G2151I only)•LED indicators for GSM/GPRS and data transmission status•Extended operating temperature from-25to70°C(G2111-T only)CertificationsIntroductionThe OnCell G2111/G2151I Series of industrial quad-band GSM/GPRS modems are designed to transmit data and short messages(SMS)over GSM/ GPRS mobile networks.The modems can be used to increase the efficiency of maintenance and communication,but do not require extensive training.In addition,the modems can be mounted on a DIN rail or wall.The OnCell G2111/G2151I Series modems accept a12to48VDC power input,making them suitable for use with a variety of field power sources.The serial ports feature15kV ESD line protection to protect the products from harmful electrical discharge,and separate RS-232and RS-422/485 interfaces are built into the OnCell G2151I,each with2.5kV RMS isolation protection for one minute.The two serial interfaces on the OnCell G2151I make it ideal for attaching all kinds of devices,such as stand-alone controllers,PC COM ports,and multi-dropped electric meters.In addition,the OnCell G2111-T has an extended operating temperature(-25to70°C)design that makes it suitable for heavy industrial use. SpecificationsCellular InterfaceCellular Standards GSM,GPRSBand Options Quad-band GSM/GPRS850MHz/900MHz/1800MHz/1900MHzGPRS Multi-Slot Class10GPRS Terminal Device Class Class BGPRS Coding Schemes CS1to CS4CSD Data Rates Up to14400bpsCellular Antenna Connectors1SMA femaleNo.of SIMs1SIM Control Voltage3VSerial InterfaceNo.of Ports1Serial Standards All models:RS-232(DB9female connector)OnCell G2151I:RS-232/422/485(5-pin terminal block connector)ESD Protection OnCell G2111:15kVIsolation OnCell G2151I:2kVData Bits8Stop Bits1Parity NoneFlow Control RTS/CTSBaudrate300bps to230.4kbpsSerial SignalsRS-232TxD,RxD,RTS,CTS,DTR,DSR,DCD,RI,GNDRS-422Tx+,Tx-,Rx+,Rx-,GNDRS-485-2w Data+,Data-,GNDRS-485-4w Tx+,Tx-,Rx+,Rx-,GNDPower ParametersInput Voltage12to48VDCPower Connector Terminal blockInput Current0.625A@12VDC,0.16A@48VDCPhysical CharacteristicsHousing ABS+PolycarbonateIP Rating IP30Dimensions27x123x79mm(1.06x4.84x3.11in)Weight155g(0.34lb)Environmental LimitsOperating Temperature OnCell G2111/G2151I:-20to55°C(-4to131°F)OnCell G2111I-T:-25to70°C(-22to158°F)Storage Temperature(package included)-40to75°C(-40to167°F)Ambient Relative Humidity5to95%(non-condensing)Standards and CertificationsSafety UL60950-1EMC EN55032/24EMI CISPR32,FCC Part15B Class AEMS IEC61000-4-2ESD:Contact:4kV;Air:8kVIEC61000-4-3RS:80MHz to1GHz:3V/mIEC61000-4-4EFT:Power:0.5kVIEC61000-4-5Surge:Power:1kVIEC61000-4-6CS:3VIEC61000-4-8PFMFRadio Frequency FCC Part22H,FCC Part24E,EN301489-1,EN301489-7,EN301511MTBFTime OnCell G2111:925,000hrsOnCell G2111-T:925,000hrsOnCell G2151I:864,000hrsStandards Telcordia SR332WarrantyWarranty Period5yearsDetails See /warrantyPackage ContentsDevice1x OnCell G2111/G2151I Series GSM/GPRS modem1Antenna1x GSM/GPRSAccessory1x terminal block for power jack connectorDocumentation1x quick installation guide1x warranty cardDimensionsOrdering InformationModel Name Cellular Standard Band Operating Temp.Serial Isolation Serial StandardsOnCell G2111GSM/GPRS 850/900/1800/1900MHz-20to55°C–RS-232OnCell G2111-T GSM/GPRS 850/900/1800/1900MHz-25to70°C–RS-232OnCell G2151I GSM/GPRS 850/900/1800/1900MHz-20to55°C✓RS-232/422/4851.An activated SIM card(not included)must be provided by a third party Cellular Service Provider.Accessories(sold separately)AntennasANT-CQB-AHSM-00-3m GSM/GPRS/EDGE,omni-directional magnetic base antenna,0dBi,3m cableANT-CQB-AHSM-03-3m GSM/GPRS/EDGE,omni-directional magnetic base antenna,3dBi,3m cableANT-CQB-AHSM-05-3m GSM/GPRS/EDGE,omni-directional magnetic base antenna,5dBi,3m cableANT-CQB-ASM-01GSM/GPRS/EDGE,omni-directional rubber duck antenna,1dBiANT-WCDMA-ANF-00GSM/GPRS/EDGE/UMTS/HSPA,omni-directional outdoor antenna,0dBiANT-WCDMA-ASM-1.5GSM/GPRS/EDGE/UMTS/HSPA,omni-directional rubber duck antenna,1.5dBiANT-WCDMA-AHSM-04-2.5m GSM/GPRS/EDGE/UMTS/HSPA,omni-directional magnetic base antenna,4dBiANT-LTE-ASM-02GPRS/EDGE/UMTS/HSPA/LTE,omni-directional rubber duck antenna,2dBiANT-LTE-ANF-04GSM/GPRS/EDGE/UMTS/HSPA/LTE,omni-directional outdoor antenna,4dBi,IP66AntennasANT-LTEUS-ASM-01GSM/GPRS/EDGE/UMTS/HSPA/LTE,omni-directional rubber duck antenna,1dBiWireless Antenna CableA-CRF-SMSF-R3-100Cellular magnetic-base SMA connector with1-meter RF cable©Moxa Inc.All rights reserved.Updated Nov12,2018.This document and any portion thereof may not be reproduced or used in any manner whatsoever without the express written permission of Moxa Inc.Product specifications subject to change without notice.Visit our website for the most up-to-date product information.。

04-5 Uhde Inventa Fischer Dr. Schaller

04-5 Uhde Inventa Fischer Dr. Schaller

PET 200'000 mt/y film grade 140'000 mt/y Direct-Film-Casting (DFC) PET 200'000 mt/y textile grade PET 250'000 mt/y textile grade PET 200'000 mt/y textile grade PET 200'000 mt/y textile grade PET 200'000 mt/y bottle grade
3
Uhde Inventa-Fischer's PET Technology Development PET plant sizes over time
1500
1200
tons/day
900
600
0.5 t/d
0
1960
1965
3 t/d
1970
300
1975
1980
Year
1985
1990
1995
Latest news in production of polyester packaging materials @
Dr. Rainer Schaller, Senior Vice President R&D
ThyssenKrupp Group
Steel
Carbon Steel Stainless Steel Special Materials
MTP MTR SSP
% of costs for SSP
120 100 80 60 40 20 0 0 100 200 300 400 mt/d 500 600
700

水王星常用配件价格表

水王星常用配件价格表

水王星常用配件价格表
品名型号市场价(元)5微米PP棉 UPP-9605 90
椰壳活性碳UGAC-96C1 115
1微米PP棉前置滤芯UPP-9601 90
椰壳活性碳UC70-96C2 115
便捷5微米PP棉滤芯UPP-1605 145
便捷椰壳颗粒活性炭滤芯UGAC-16C1 170
便捷椰壳柱状活性炭滤芯UC70-16C2 180
后置椰壳活性炭滤芯UCL-33 80
优能抗菌活性炭滤芯UAN-33 145
孟宗竹竹晶炭滤芯UBN-33 145
优能电位能量滤芯UEN-33 370
碱性活性钙UCA-33 370
活矿磁整水器SE-1500 125
竹晶碳滤芯UBN-66 235
电位能量活水器UEN-66 620
碱性活性钙UCA-66 620
陶氏RO反渗透膜YM1812-75 360
反渗透RO膜YM2812-300 900 RO膜YM1810-75 360
水压表220 PE管177白850 PE管178白880
低压开关50
高压开关60
马达375
变压器135
多功能扳手15
龙头扳手180
进水长三通20
进水阀18
桶球阀30
PE管刀13 4042接头 4
4044接头 4 1044接头 4 704接头11 154接头 5 004接头 2 4046接头 5 变压器大360 进水阀3分25 废水比400 40 废水比550 40 4066接头8 6044接头 6 7544接头 6 1564接头8 2分电磁阀150 3分电磁阀375。

ISO 4401大小的油气方向阀说明书

ISO 4401大小的油气方向阀说明书

Options:only for DH-04 and DK-14, see section ݚ:/A = actuator device mounted on side of port B only for DP:/H = adjustable chokes for controlling the main spool shifting time(meter-out to the pilot chambers of the main valve)/H9= adjustable chokes for controlling the main spool shifting time(meter-in to the pilot chambers of the main valve)/R = with check valve on port P/S = main spool stroke adjustment (not available for DP-1*)Valve configuration, see section ݚ0= free, without springs1= spring centered, without detent 3= spring offset external position5= 2 external positions, with detent (only for DH and DK)7= center and external positionsHydraulic operated directional valvesISO 4401 size 06, 10, 16, 25 and 32Table E225-1/EHydraulic operated directional valves are spool type, three or four way, two or three position, designed to operate in oil hydraulic systems.Available with single or double hydraulic actuator.DH-0 = ISO 4401 size 06, flow up to 50 l/min DK-1 = ISO 4401 size 10, flow up to 160 l/min DP-1 = ISO 4401 size 10, flow up to 160 l/min DP-2 = ISO 4401 size 16, flow up to 300 l/min DP-3 = ISO 4401 size 25, flow up to 600 l/min DP-4 = ISO 4401 size 25, flow up to 700 l/min DP-6 = ISO 4401 size 32, flow up to 1000 l/min Max pressure:350 bar for DH-0, DP-1,DP-2, DP-3, DP-6315 bar for DK-1DH-0Type of actuator:4 = single actuator 5 = double actuatorSpool type, see section ݛ1MODEL CODEE225413/A **/*Directional control valve,size:DH-0 = 06DK-1 = 10DP-1 = 10DP-2 = 16DP-3 = 25DP-4 = 25 (high flow)DP-6 = 32Series numberHYDRAULIC CHARACTERISTICS2see note (1)3 (min) 5 (suggested)70Acting the actuator on port A,the hydraulic connections are P →B, A →T, except for spool type 4 and 5 where the con-nections are P →A, B →T.OperationThe spool displacement is achieved by hydraulic pressure on one of the pilot chambers, while the other is unloaded.When pressurizing port X, the port Y has to be directly connected to the tank at null pressure and viceversa.By pressurizing port X, the hydraulic connections are P →A, B →T, except for spool type 4 and 5 where the connections are P →B, A →T.In the spring centered versions the spool is centered by the spring action when both the pilot chambers are unloaded.1) The max pressure on port T has to be not over 50% of pilot pressure.Valve modelMax recommended flow [l/min]Max pressure on port P, A, B[bar]Max pressure on port T (also X, Y for DP)[bar]Minimum pilot pressure[bar]Max recommended pressure on piloting line[bar]3502504250DH-050350DK-1160315DP-1160DP-2300DP-3600DP-4700DP-61000Seals material:omit for NBR (mineral oil & water glycol)PE = FPM3MAIN CHARACTERISTICS OF HYDRAULIC OPERATED DIRECTIONAL VALVESAssembly position / location Any position except for valves type DH-050, DK-150, DP-*50 (without springs) that must be installed withtheir longitudinal axis horizontalSubplate surface finishing Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101)Ambient temperature-20°C to + 70°CFluid Hydraulic oil as per DIN 51524...535, for other fluids see section ݗRecommended viscosity15 ÷ 100 mm2/s at 40°C (ISO VG 15 ÷ 100)Fluid contamination class ISO 4406 class 21/19/16 NAS 1638 class 10, in line filters of 25 μm (β25 _>75 recommended)Fluid temperature-20°C +60°C (standard seals) -20°C +80°C (/PE seals)4CONFIGURATIONS and SPOOLS valves type DH-*, DK-*NOTES-Spools type 0 and 3 are also available as 0/1 and 3/1, where in centre position oil passage from ports to tank are restricted;-Spools type 1,4 and 5 are also available as 1/1, 4/8 and 5/1. They are properly shaped to reduce water-hammer shocks during the switching;-Spool type 1, 3, 8 and 1/2 for DH-0 and DK-1 are available as 1P, 3P, 8P (only for DH-0), and 1/2P to limit valve leakage.-On request, other type of spools are available.5CONFIGURATIONS and SPOOLS valves type DP-*NOTES-Spools type 0 and 3 are also available as 0/1 and 3/1, where in centre position oil passage from ports to tank are restricted;-Spools type 1,4 and 5 are also available as 1/1, 4/8 and 5/1 (not available for DP-6). They are properly shaped to reduce water-hammer shocks during the switching;-On request, other type of spools are available.6Q/Δp DIAGRAMSDH-0See note and diagrams on table E010 relating the DH* valve from which DH-0* are derivatedDK-1See note and diagrams on table E025 relating the DKE, DKER valve from which DK-1* are derivatedDP-1See note and diagrams on table E085 relating the DPH*-1 valve from which DP-1* are derivatedDP-2See note and diagrams on table E085 relating the DPH*-2 valve from which DP-2* are derivatedDP-3See note and diagrams on table E085 relating the DPH*-3 valve from which DP-3* are derivatedDP-4See note and diagrams on table E085 relating the DPH*-4 valve from which DP-4* are derivatedDP-6See note and diagrams on table E085 relating the DPH*-6 valve from which DP-6* are derivated7DIMENSIONS OF HYDRAULIC OPERATED VALVES ISO 4401 size 06 and 10 [mm]E2258DIMENSIONS OF HYDRAULIC OPERATED VALVES ISO 4401 size 16, 25 and 32 [mm]06/13。

西门子(Siemens)测试套装用户说明书

西门子(Siemens)测试套装用户说明书

sTest Kit, Communication Adapter, Power SupplyDispositivo de prueba Pocket de test pour11323Installation Instructions / Instructivo de InstalaciónUse only with Siemens certified Components.Utilizar únicamente con componentes certificados de Siemens.A utiliser uniquement avec les composants certifiés Siemens.Turn off and lock out all power supplying this device before Couper Tensión Tension dangereuse.Hazardous Voltage.working on this device.Replace all covers before power supplying this device is turned on.l'alimentation de l'appareil et barrer avant de travailler.Remplacez touts les couverts avant que l'approvisionnement de pouvoir soit alimenté.peligrosa.Puede causar la muerte o lesiones graves.Danger de mort ou risque de blessures graves.Will cause death or serious injury.Desenergice totalmente antes de instalar o darle servicio. Reemplace todas las barreras y cubiertas antes de energizar el interruptor.For Use With Frame DG, FG, JG, LG, MG, NG & PG Para Usar Con Caja Base DG, FG, JG, LG, MG, NG & PGU.S. Cat. No.Euro Order No.9 lb.in.[ 1.0 Nm ]UPAPELTK 3VL9000-8AL01Accessory [ Accesorio ]ELTPHB3VL9000-8AK013 x 9VItem:ELTPHB 3VL9000-8AK01Cal. ISO 67892NOTE -These instructions do not purport to cover all details or variations in equipment, or to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise, which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to the local Siemens sales office. The contents of this instruction manual shall not become part of or modify any prior or existing agreement, commitment or relationship. The sales contract contains the entire obligation of Siemens. The warranty contained in the contract between the parties is the sole warranty of Siemens. Any statements contained herein do not create new warranties or modify the existing warranty.Trademarks -Unless otherwise noted, all names identified by ®are registered trademarks of Siemens AG or Siemens Industry, Inc. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.ON / I4CT Test:[ CT Prueba: ]567Option [ Opción ]ok ok2ON / I35Trip Test:[ Interrumpir Prueba ]CT Test:[ CT Prueba: ]6UPAPELTK \3VL9000-8AL01Call Technical Support [ Lamar a Soporte Técnico ]1O / OFF74I / ON12okokBattery Low Step -2POWER okokStep -289Trip Test:[ Interrumpir Prueba ]Trip Unit -545 –Only[ Disparador -545 ] -SolamenteTurn off and lock out all power supplying this device before Couper Tensión Tension dangereuse.Hazardous Voltage.working on this device.Replace all covers before power supplying this device is turned on.l'alimentation de l'appareil et barrer avant de travailler.Remplacez touts les couverts avant que l'approvisionnement de pouvoir soit alimenté.peligrosa.Puede causar la muerte o lesiones graves.Danger de mort ou risque de blessures graves.Will cause death or serious injury.Desenergice totalmente antes de instalar o darle servicio. Reemplace todas las barreras y cubiertas antes de energizar el interruptor.MINMIN1ON / I4ELTPHB 3VL9000-8AP01ON / I56Test:[ Prueba: ]7Trip [ Interrumpir ]OK 82ON / I3O / OFF9OKCall Technical Support [ Lamar a Soporte Técnico ]10Ground Fault Test:[Prueba: Falla a Tierra]Trip Unit -545 with Ground Fault –Only [ Disparador –545 con Falla a Tierra ] -Solamente11MAXMAXMAX1ON / I4ELTPHB3VL9000-8AP01ON / I56Test:[ Prueba: ]7Trip[ Interrumpir]OK82ON / I3O / OFF9OKCall Technical Support[ Lamar a Soporte Técnico ]Test Settings [ Ajuste de prueba ]Value [ Valor ]Screen [ Pantalla ]I i = 1.25 X I n AmpsI i IOC AMPS –[ AMPS SOBREC INST ]806932Setting Menus [ Menus de Ajuste ]Trip Test:[ Interrumpir Prueba ]12131ON / I4ELTPHB 3VL9000-8AP01ON / I56Test:[ Prueba: ]7Trip [ Interrumpir ]OK 82ON / I3O / OFF9OKCall Technical Support [ Lamar a Soporte Técnico ]Trip Unit -576 –Only[ Disparador -576 ] -SolamenteFor Support in Europe refer to :Bestell-Nr. / Order No.: 3ZX1012-0VL68-1AA0 Internet: www.siemens.de/lowvoltage/technical-assistance GWA 4NEB 179 6819-10 DS04Ground Fault Test:[Prueba: Falla a Tierra ]141621806932Setting Menus [ Menus de Ajuste ]3 lb. in.[ 0.3 Nm ]Option : [ Opción ]:315Test Settings [ Ajuste de prueba ]Value [ Valor ]Screen [ Pantalla ]I r = 1.0 X I n Amps I r CONTINUOUS AMPS –[ AMPERIOS CONT ]= GND RESIDUAL [ = RESIDUAL ]I iGROUND FAULT TYPE –[ TIPO FALLA TIERR-]t sd = 0.5 sec.t sd SHORT TIME DELAY –[ RETARDO CORTO ]I sd = 6 X I r Amps I sd SHORT TIME PICK UP –[ TIEMPO CORTO INICIO ]t r = 30 st r LONG TIME DELAY –[ RETARDO LARGO ]IOC AMPS –[ AMPS SOBREC INST ]I i = 6 X I n AmpsTrip Unit -576 with Ground Fault –Only [ Disparador –576 con Falla a Tierra ] -Solamente1ON / I4ELTPHB 3VL9000-8AP01ON / I56Test:[ Prueba: ]7Trip [ Interrumpir ]OK 82ON / I3O / OFF9OKCall Technical Support [ Lamar a Soporte Técnico ]1.5”[ 38 mm ]MAX.Technical Support:Toll Free: 1-800-241-4453Internet: /powerdistribution。

PowerTech 4.5 升和 6.8 升柴油发动机基本发动机说明书

PowerTech 4.5 升和 6.8 升柴油发动机基本发动机说明书

PowerTech™4.5L and6.8LDiesel Engines Base EngineFor complete service information also see:PowerTech™Diesel Engines—Mechanical Fuel Systems.......................................................CTM207PowerTech™Diesel Engines—Level 4Electronic Fuel Systems with Bosch VP44Pump.....................................................................CTM170PowerTech™Diesel Engines—Level 12Electronic Fuel Systems with Stanadyne DE10Pump.....................................................................CTM331PowerTech™Diesel Engines—Level 1Electronic Fuel Systems with Delphi/Lucas DP201Pump.........................................................CTM284PowerTech™Diesel Engines—Level 11Electronic Fuel Systems with Denso HPCR......CTM220PowerTech™Diesel Engines and PowerTech™Plus—Level 14Electronic Fuel Systems with Denso HPCR........................................................CTM320PowerTech™Diesel Engines and PowerTech™E—Level 16Electronic Fuel Systems with Denso HPCR........................................................CTM502Alternators and Starter Motors..........................CTM77OEM Engine Accessories...................................CTM67Application List....................................................CTM106819JDPS Master Tool Manual...................................TM111119COMPONENT TECHNICAL MANUAL PowerTech™4.5L and 6.8L DieselEngines—Base EngineCTM10407NOV12(ENGLISH)John Deere Power SystemsLITHO IN U.S.A.IntroductionDPSG,OUO1004,2767-19-29OCT10-1/1ForewordThis manual is written for an experienced technician.Essential tools required in performing certain service work are identified in this manual and are recommended for use.This manual (CTM104)covers only the engine base for all PowerTech™4.5L and 6.8L engines includingPowerTech™”Plus”engine model as well as PowerTech™”E”and PowerTech™”M”engine models.It is one of eight volumes on 4.5L and 6.8L engines.The following seven companion manuals cover fuel system and electronics repair,operation and diagnostics:•CTM207—Mechanical Fuel Systems•CTM170—Level 4Electronic Fuel Systems with Bosch VP44Pump•CTM331—Level 12Electronic Fuel Systems with Stanadyne DE10Pump•CTM284—Level 1Electronic Fuel Systems with Delphi/Lucas DP201Pump•CTM220—Level 11Electronic Fuel Systems with Denso High Pressure Common Rail•CTM320—Level 14Electronic Fuel Systems with Denso High Pressure Common Rail•CTM502—Level 16Electronic Fuel Systems with Denso High Pressure Common RailOther manuals will be added in the future to provide additional information on electronic fuel systems as needed.Live with safety:Read the safety messages in the introduction of this manual and the cautionspresented throughout the text of the manual.This is the safety-alert symbol.When you see this symbol on the machine or in this manual,be alert to the potential for personal injury.Use this component technical manual in conjunction with the machine technical manual.An applicationlisting in Section 01,Group 001identifiesproduct-model/component type-model relationship.See the machine technical manual for information on component removal and installation,and gaining access to the components.Information is organized in sections and groups for the various components requiring service instruction.Section 05summarizes all applicable essential tools,service equipment and tools,other materials needed to do the job,and service parts kits.Section 06summarizes all specifications,wear tolerances,and torque values.Before beginning repair on an engine,clean the engine and mount on a repair stand.(See Section 02,Group 010.)This manual contains SI Metric units of measure followed immediately by the U.S.customary units of measure.Most hardware on these engines is metric sized.Some components of this engine may be serviced without removing the engine from the machine.Refer to the specific machine technical manual for information on components that can be serviced without removing the engine from the machine and for engine removal and installation procedures.Read each block of material completely before performing service to check for differences in procedures orspecifications.Follow only the procedures that apply to the engine model number you are working on.If only one procedure is given,that procedure applies to all the engines in the manual.CALIFORNIA PROPOSITION 65WARNINGDiesel engine exhaust and some of its constituents are known to the State of California to cause cancer,birth defects and other reproductive harm.PowerTech is a trademark of Deere &CompanyRecord of ChangesPublication and Translation DateCTM104_17DEC09Section-Group Group Title Block Title Comment01-001Engine Identification andApplication Charts Engine Application Charts Moved to Application manual(CTM106819)02-050Camshaft,Balancer Shafts andTiming Gear Train Time Camshaft and Fuel InjectionPump(Non-HPCR Engines)Add procedure for injection pumpwith lock shaft timing.04-150Observable Diagnostics and Tests Test Engine Compression Pressure Added new compression adapterJDG10824,JDG11064,JDG1106506-210Diagnostic Specifications Intake Manifold Pressure(Turbocharger Boost)Specifications Update with new applications:•J06068HCQ07•PE6068HT082/083/085•J06068HCQ04•PE4045HLV56/58/60/62/64/66•PE6068AFM75•JO6068HBM04CD03523,00001D2-19-03SEP10-1/1DPSG,OUO1004,129-19-03DEC07-1/1RG7636—UN—23NOV973/4Right Rear ViewRG7638—UN—23NOV973/4Left Rear ViewRG7639—UN—23NOV973/4Right Front ViewRG7637—UN—23NOV973/4Left Front ViewPowerTech is a trademark of Deere&CompanyOUO1080,0000238-19-03DEC07-1/1R G 11932—U N —06N O V 013/4Right Front View—Two-Valve Head EngineR G 11931—U N —06N O V 013/4Left Rear View—Two-Valve Head EngineR G 13617A —U N —18M A Y 043/4Right Front View—Four-Valve Head EngineR G 13618A —U N —18M A Y 043/4Left Rear View—Four-Valve Head EnginePowerTech is a trademark of Deere &CompanyThanks very much for your reading, Want to get more information,Please click here, Then get the complete manualNOTE:If there is no response to click on the link above, please download the PDF document first, and then click on it.Have any questions please write to me: ******************************DPSG,OUO1004,130-19-29NOV07-1/1RG7641—UN—23NOV973/4Right Front ViewRG764—UN—23NOV973/4Left Front ViewRG7643—UN—23NOV973/4Right Rear ViewRG7642—UN—23NOV973/4Left Rear ViewPowerTech is a trademark of Deere&CompanyOUO1080,0000239-19-29OCT10-1/1OUO1083,00005FC -19-29OCT10-1/1R G 11934—U N —24O C T 013/4Right Front View—Two-Valve Head Engine R G 11933—U N —24O C T 013/4Left Rear View—Two-Valve Head EnginePowerTech™6.8L Engine With Electronic Fuel System—Tier 2/Stage IIR G 12199—U N —24M A Y 026068HF475Four-Valve Engine (Level 11Electronic Fuel Systemwith Denso High Pressure Common Rail)R G 12200—U N —24M A Y 026068HF475Four-Valve EngineOUO1083,00005FC -19-29NOV07-1/1PowerTech™Plus 6.8L Engine With Electronic Fuel System—Tier 3/Stage IIIAR G 13547—U N —11N O V 046068HF485Engine Shown (Electronic Fuel System WithDenso High Pressure Common Rail)R G 13546—U N —11N O V 046068HF485ShownPowerTech is a trademark of Deere &CompanyOURGP12,00001EA -19-29NOV07-1/1PowerTech™E 4.5L Engine With Electronic Fuel Systems (HPCR Fuel System)(Two-Valve Cylinder Head)R G 14632—U N —13A P R 064045HF285EngineR G 14633—U N —13A P R 064045HF285EnginePowerTech is a trademark of Deere &CompanyOURGP12,00001EB -19-29NOV07-1/1PowerTech™E 6.8L Engine With Electronic Fuel Systems (HPCR Fuel System)(Two-Valve Cylinder Head Model)R G 14634A —U N —29N O V 076068HF285Engine (3/4Right Front View)C D 31001—U N —29N O V 076068HF285Engine (3/4Left Front View)PowerTech is a trademark of Deere &CompanyCD03523,00001B4-19-03DEC07-1/1PowerTech™M 4.5L Engine withMechanical Fuel System and 17mm InjectorsC D 31002—U N —29N O V 074045HF280Engine (3/4Left Front View)PowerTech is a trademark of Deere &CompanyContentsSection01—General InformationGroup000—SafetyGroup001—Engine Identification and ApplicationChartsGroup002—Fuels,Lubricants and CoolantsSection02—Repair and AdjustmentsGroup010—Engine RebuildGroup020—Cylinder Head and Valves(Two-ValveHead Engines)Group021—Cylinder Head and Valves(Four-ValveHead Engines)Group030—Cylinder Block,Liners,Pistons and RodsGroup040—Crankshaft,Main Bearings and FlywheelGroup050—Camshaft,Balancer Shafts and TimingGear TrainGroup060—Lubrication SystemGroup070—Cooling SystemGroup080—Air Intake and Exhaust SystemGroup090—Fuel SystemGroup100—Starting and Charging SystemsSection03—Theory of OperationGroup120—Base Engine OperationSection04—DiagnosticsGroup150—Observable Diagnostics and TestsSection05—Tools and Other MaterialsGroup170—Repair Tools and Other MaterialsGroup180—Diagnostic Service ToolsGroup190—Dealer Fabricated Service ToolsSection06—SpecificationsGroup200—Repair and General OEM SpecificationsGroup210—Diagnostic SpecificationsOriginal Instructions.All information,illustrations and specifications in thismanual are based on the latest information available at the time of publication.The right is reserved to make changes at any time without notice.COPYRIGHT©2012DEERE&COMPANYMoline,IllinoisAll rights reserved.A John Deere ILLUSTRUCTION®ManualPrevious EditionsCopyright©1996,1998,2000,2002,2004,2005,2007,2008,2009,2010ContentsSection01General Information ContentsPage Group000—SafetyWork In Ventilated Area...............................01-000-1 Recognize Safety Information.....................01-000-1 Work in Clean Area.....................................01-000-1 Dispose of Waste Properly..........................01-000-2 Avoid Harmful Asbestos Dust......................01-000-2 Handle Fuel Safely—Avoid Fires.................01-000-2 Prepare for Emergencies.............................01-000-3 Handle Starting Fluid Safely........................01-000-3 Handle Fluids Safely—AvoidFires.........................................................01-000-3 Avoid High-Pressure Fluids.........................01-000-4 Use Proper Lifting Equipment......................01-000-4 Illuminate Work Area Safely........................01-000-4 Live With Safety...........................................01-000-5 Service Machines Safely.............................01-000-5 Handle Chemical Products Safely................01-000-5 Protect Against Noise..................................01-000-6 Remove Paint Before Welding orHeating....................................................01-000-6 Stay Clear of Rotating Drivelines.................01-000-7 Service Cooling System Safely...................01-000-7 Follow Safety Instructions............................01-000-8 Use Proper Tools.........................................01-000-8 Construct Dealer-Made ToolsSafely.......................................................01-000-8 Practice Safe Maintenance..........................01-000-9 Understand Signal Words............................01-000-9 Replace Safety Signs................................01-000-10 Prevent Battery Explosions.......................01-000-10 Protect Against High PressureSpray.....................................................01-000-10 Avoid Heating Near PressurizedFluid Lines.............................................01-000-11 Wear Protective Clothing...........................01-000-11 Wait Before OpeningHigh-Pressure Fuel System...................01-000-11 Handle Agricultural ChemicalsSafely.....................................................01-000-12 Handling Batteries Safely..........................01-000-13 Install All Guards.......................................01-000-13 Avoid Hot Exhaust.....................................01-000-14 Group001—Engine Identification andApplication ChartsEngine Serial Number PlateInformation...............................................01-001-1 OEM Engine Option Code Label.................01-001-3 Information Relative to EmissionsRegulations..............................................01-001-3 Group002—Fuels,Lubricants and Coolants Diesel Fuel...................................................01-002-1 Diesel Fuel Additive Products......................01-002-1Page Biodiesel Fuel..............................................01-002-2 Minimizing the Effect of ColdWeather on Diesel Engines.....................01-002-4 Handling and Storing Diesel Fuel................01-002-5 Lubricity of Diesel Fuel................................01-002-5 Testing Diesel Fuel......................................01-002-5 Oil Information for Uncertified orTier1Engines..........................................01-002-5 Diesel Engine Oil.........................................01-002-6 Oil Information for Tier2Engines................01-002-6 Diesel Engine Oil.........................................01-002-7 Oil Information for Tier3Engines................01-002-7 Diesel Engine Oil.........................................01-002-8 Diesel Engine Break-In Oil..........................01-002-9 Oil Filters.....................................................01-002-9 Grease.......................................................01-002-10 Alternative and SyntheticLubricants..............................................01-002-10 Lubricant Storage......................................01-002-10 Mixing of Lubricants...................................01-002-11 Heavy Duty Diesel EngineCoolant..................................................01-002-11 Supplemental Coolant Additives................01-002-12 Operating in Warm TemperatureClimates.................................................01-002-12 Additional Information AboutDiesel Engine Coolants andJohn Deere LIQUID COOLANTCONDITIONER.....................................01-002-13 Diesel Engine Coolant...............................01-002-14 Testing Diesel Engine Coolant...................01-002-14 Drain Intervals for Diesel EngineCoolant..................................................01-002-15ContentsGroup 000SafetyDX,AIR -19-17FEB99-1/1DX,ALERT -19-29SEP98-1/1DX,CLEAN -19-04JUN90-1/1Work In Ventilated AreaEngine exhaust fumes can cause sickness or death.If it is necessary to run an engine in an enclosed area,remove the exhaust fumes from the area with an exhaust pipe extension.If you do not have an exhaust pipe extension,open the doors andget outside air into the area.T S 220—U N —23A U G 88Recognize Safety InformationThis is a safety-alert symbol.When you see this symbol on your machine or in this manual,be alert to the potential for personal injury.Followrecommended precautions and safe operating practices.T 81389—U N —07D E C 88Work in Clean AreaBefore starting a job:•Clean work area and machine.•Make sure you have all necessary tools to do your job.•Have the right parts on hand.•Read allinstructions thoroughly;do not attemptshortcuts.T 6642E J —U N —18O C T 88DX,DRAIN -19-03MAR93-1/1DX,DUST -19-15MAR91-1/1DX,FIRE1-19-12OCT11-1/1Dispose of Waste ProperlyImproperly disposing of waste can threaten theenvironment and ecology.Potentially harmful waste used with John Deere equipment include such items as oil,fuel,coolant,brake fluid,filters,and batteries.Use leakproof containers when draining fluids.Do not use food or beverage containers that may mislead someone into drinking from them.Do not pour waste onto the ground,down a drain,or into any water source.Air conditioning refrigerants escaping into the air can damage the Earth’s ernment regulations may require a certified air conditioning service center torecover and recycle used air conditioning refrigerants.T S 1133—U N —26N O V 90Inquire on the proper way to recycle or dispose of waste from your local environmental or recycling center,or from your John Deere dealer.Avoid Harmful Asbestos DustAvoid breathing dust that may be generated whenhandling components containing asbestos fibers.Inhaled asbestos fibers may cause lung cancer.Components in products that may contain asbestosfibers are brake pads,brake band and lining assemblies,clutch plates,and some gaskets.The asbestos used in these components is usually found in a resin or sealed in some way.Normal handling is not hazardous as long as airborne dust containing asbestos is not generated.Avoid creating dust.Never use compressed air for cleaning.Avoid brushing or grinding material containing asbestos.When servicing,wear an approved respirator.A special vacuum cleaner is recommended to clean asbestos.If not available,apply a mist of oilor water on the material containing asbestos.T S 220—U N —23A U G 88Keep bystanders away from the area.Handle Fuel Safely—Avoid FiresHandle fuel with care:it is highly flammable.Do not refuel the machine while smoking or when near open flame or sparks.Always stop engine before refueling machine.Fill fuel tank outdoors.Prevent fires by keeping machine clean of accumulated trash,grease,and debris.Always clean up spilled e only an approved fuel container for transporting flammable liquids.Never fill fuel container in pickup truck with plastic bed liner.Always place fuel container on ground beforerefueling.Touch fuel container with fuel dispenser nozzle before removing can lid.Keep fuel dispenser nozzle in contactwith fuel container inlet when filling.T S 202—U N —23A U G 88Do not store fuel container where there is an open flame,spark,or pilot light such as within a water heater or other appliance.DX,FIRE2-19-03MAR93-1/1DX,FIRE3-19-16APR92-1/1DX,FLAME -19-29SEP98-1/1Prepare for EmergenciesBe prepared if a fire starts.Keep a first aid kit and fire extinguisher handy.Keep emergency numbers for doctors,ambulance service,hospital,and fire department near your telephone.T S 291—U N —23A U G 88Handle Starting Fluid SafelyStarting fluid is highly flammable.Keep all sparks and flame away when using it.Keep starting fluid away from batteries and cables.To prevent accidental discharge when storing thepressurized can,keep the cap on the container,and store in a cool,protected location.Do not incinerateor puncture a starting fluid container.T S 1356—U N —18M A R 92Handle Fluids Safely—Avoid FiresWhen you work around fuel,do not smoke or work near heaters or other fire hazards.Store flammable fluids away from fire hazards.Do not incinerate or puncture pressurized containers.Make sure machine is clean of trash,grease,and debris.Do not store oilyrags;they can ignite and burn spontaneously.T S 227—U N —23A U G 88DX,FLUID -19-12OCT11-1/1DX,LIFT -19-04JUN90-1/1DX,LIGHT -19-04JUN90-1/1Avoid High-Pressure FluidsInspect hydraulic hoses periodically –at least once per year –for leakage,kinking,cuts,cracks,abrasion,blisters,corrosion,exposed wire braid or any other signs of wear or damage.Replace worn or damaged hose assemblies immediately with John Deere approved replacement parts.Escaping fluid under pressure can penetrate the skin causing serious injury.Avoid the hazard by relieving pressure before disconnecting hydraulic or other lines.Tighten all connections before applying pressure.Search for leaks with a piece of cardboard.Protect hands and body from high-pressure fluids.If an accident occurs,see a doctor immediately.Any fluid injected into the skin must be surgically removed within a fewhours or gangrene may result.Doctors unfamiliarX 9811—U N —23A U G 88with this type of injury should reference a knowledgeable medical source.Such information is available inEnglish from Deere &Company Medical Department in Moline,Illinois,U.S.A.,by calling 1-800-822-8262or +1309-748-5636.Use Proper Lifting EquipmentLifting heavy components incorrectly can cause severe injury or machine damage.Follow recommended procedure for removaland installation of components in the manual.T S 226—U N —23A U G 88Illuminate Work Area SafelyIlluminate your work area adequately but e a portable safety light for working inside or under the machine.Make sure the bulb is enclosed by a wire cage.The hot filament of an accidentally broken bulbcan ignite spilled fuel or oil.T S 223—U N —23A U G 88DX,LIVE -19-25SEP92-1/1DX,LOOSE -19-04JUN90-1/1DX,MSDS,NA -19-03MAR93-1/1Live With SafetyBefore returning machine to customer,make sure machine is functioning properly,especially thesafety systems.Install all guards and shields.T S 231—19—07O C T 88Service Machines SafelyTie long hair behind your head.Do not wear a necktie,scarf,loose clothing,or necklace when you work near machine tools or moving parts.If these items were to get caught,severe injury could result.Remove rings and other jewelry to preventelectrical shorts and entanglement in moving parts.T S 228—U N —23A U G 88Handle Chemical Products SafelyDirect exposure to hazardous chemicals can causeserious injury.Potentially hazardous chemicals used with John Deere equipment include such items as lubricants,coolants,paints,and adhesives.A Material Safety Data Sheet (MSDS)provides specific details on chemical products:physical and health hazards,safety procedures,and emergency response techniques.Check the MSDS before you start any job using ahazardous chemical.That way you will know exactly what the risks are and how to do the job safely.Then follow procedures and recommended equipment.(See your John Deere dealer for MSDS’s onchemical products used with John Deere equipment.)T S 1132—U N —26N O V 90DX,NOISE -19-03MAR93-1/1DX,PAINT -19-24JUL02-1/1Protect Against NoiseProlonged exposure to loud noise can cause impairment or loss of hearing.Wear a suitable hearing protective device such asearmuffs or earplugs to protectagainst objectionable or uncomfortable loud noises.T S 207—U N —23A U G 88Remove Paint Before Welding or HeatingAvoid potentially toxic fumes and dust.Hazardous fumes can be generated when paint is heated by welding,soldering,or using a torch.Remove paint before heating:•Remove paint a minimum of 100mm (4in.)from area to be affected by heating.If paint cannot be removed,wear an approved respirator before heating or welding.•If you sand or grind paint,avoid breathing the dust.Wear an approved respirator.•If you use solvent or paint stripper,remove stripper with soap and water before welding.Remove solvent or paint stripper containers and other flammable material from area.Allow fumes to disperse at least 15minutes before welding or heating.Do not use a chlorinated solvent inareas where welding will take place.T S 220—U N —23A U G 88Do all work in an area that is well ventilated to carry toxic fumes and dust away.Dispose of paint and solvent properly.。

PP用料-家电专用

PP用料-家电专用

家电壳体专用料对于家电壳体来说,具有高的强度(平衡的刚性/韧性性能)以及能吸引入的外观是最重要的。

该用途的聚丙烯专用料大多属高性能品种,有高模量、高耐冲击强度及高流动性。

大多属阻燃级,其中不少为复合物或合金,容易用色母粒着色,工艺简单。

Targor公司最近推出牌号为MetoceneX50081的茂金属PP,其密度降低15%,断裂强度、流动性、刚性、光泽度和脱模性高,因此可注塑防扭曲的薄壁制品,如CD盒、薄壁家用制品、家电制品等。

Borealis聚烯烃公司称其推出的PP专用料达到UL94V0阴燃标准,适用于电视机后壳、内框和部件。

Ferro公司推出的高抗冲击性、低翘曲的MPP25FU22HB共聚yy,可用于生产音响的扬声器。

日本住友公司的Noblen专用料也广泛用于电扇、换气扇等家电中。

如在电扇中:AH561、AV585、AW564用于电动机盖,BG20A用于风叶,AH585、AZ564、BG20A用于扇叶;换气扇中:AH585用于扇壳,AW564用于风叶;电动吸尘器中:BG20A用于主体,AW564用于车轮,WP950、AY764用于收藏盒;餐具干燥器中:WP834A用于盖,AY564用于主体。

美国Solar公司亦用Ferro公司的玻纤增强PP制造家用除草机外壳,该材料有优异的刚性、韧性、防翘曲性及紫外线稳定性。

美国的埃克森公司开发出注塑级的茂金属等规PP,瞄准的市场为型家电制品,其中牌号MDS253己在家用制品、家电壳体等上应用。

洗衣机专用料国外生产洗衣机专用高抗冲级聚丙烯嵌段共聚物的厂家较多,牌号也很多,适合薄壁洗衣机桶的PP专用料代表性牌号为日本住友化学的AZ-56 4,相应的洗衣机的甩干桶、底座、面盖、波轮、电钮板用代表牌号为住友的AW-564。

AMOCO公司与日本窒素公司合作开发的Accpro 9346树脂是一种注塑级、高刚性的核化可用于甩干桶。

其MFR为5g/10min的注塑级牌号树脂,应用于美国通用电气公司新型洗衣机的内桶,减轻了重量,具有极好的色泽。

Rubson Aero 360 潮湿调节剂数据安全卡说明书

Rubson Aero 360 潮湿调节剂数据安全卡说明书

Ficha de Datos de Seguridad según el Reglamento (CE) n° 1907/2006página 1 de 9Rubson Aero 360Nº FDS : 505142V002.2Revisión: 21.12.2016Fecha de impresión: 17.07.2017Reemplaza la versión del: 01.12.20161.1. Identificador del productoRubson Aero 3601.2. Usos pertinentes identificados de la sustancia o de la mezcla y usos desaconsejadosUso previsto:Deshumidificador1.3. Datos del proveedor de la ficha de datos de seguridadHENKEL IBERICA S.A. Bilbao 72-84 08005 BarcelonaEspañaTeléfono: +34 (93) 290 4201 Fax:+34 (93) 290 4181*****************************.com1.4. Teléfono de emergenciaAsistencia en español: Henkel Ibérica, S.A: (+34)93 290 4100 (Centralita, 24h) ó (+34)704 10 00 87 (Emergencias de transporte)Instituto Nacional de Toxicología: Tel (emergency): +34.91.562.04.202.1. Clasificación de la sustancia o de la mezclaClasificación (CLP):Corrosivo para los metalesCategoría 1 H290 Puede ser corrosivo para los metales. Irritación ocularCategoría 2H319 Provoca irritación ocular grave.2.2. Elementos de la etiqueta Elementos de la etiqueta (CLP):Pictograma de peligro:Palabra de advertencia:AtenciónIndicación de peligro: H290Puede ser corrosivo para los metales.H319Provoca irritación ocular grave.Consejo de prudencia: P101Si se necesita consejo médico, tener a mano el envase o la etiqueta.P102Mantener fuera del alcance de los niños.P280Úsese protección para los ojos/la cara.P305+P351+P338EN CASO DE CONTACTO CON LOS OJOS:Aclarar cuidadosamentecon agua durante varios minutos. Quitar las lentes de contacto, si lleva y resulta fácil.Seguir aclarando.P337+P313Si persiste la irritación ocular: Consultar a un médico.2.3. Otros peligrosNinguno si se usa según lo dispuesto.No cumple con los criterios de Persistente, Bioacumulativo y Tóxico (PBT), ni con los de muy Persistente y muy Bioacumulativo (vPvB.3.2. MezclasDescripción química general:Agente deshumificadorSustancias base de la preparación:Chloruro de CalcioDeclaración de componentes conforme al Reglamento CLP (CE) No. 1272/2008:Ver el texto completo de las frases H y otras abreviaturas en la sección 16 "Otros datos".Para sustancias sin clasificación pueden existir límites de exposición en los lugares de trabajo.4.1. Descripción de los primeros auxiliosInformación general:En caso de malestar acudir a un médico.Inhalación:Aire fresco, si persisten los síntomas consultar al doctor.Contacto de la piel:Lavar con agua corriente y jabon. Cuidar la piel. Separar las ropas contaminadas.Contacto con los ojos:Lavar los ojos inmediatamente con agua o con una solución de limpieza para los ojos durante 5 minutos como mínimo. Si el dolor no desaparece (escozor intenso, sensibilidad a la luz, alteración de la capacidad visual), continuar limpiando y ponerse en contacto o acudir a un médico u hospital.Ingestión:Lavado de la cavidad bucal. Beber 1-2 vasos de agua, consultar con un médico.4.2. Principales síntomas y efectos, agudos y retardadosOJOS: Irritación, conjuntivitis.4.3. Indicación de toda atención médica y de los tratamientos especiales que deban dispensarse inmediatamente Véase la sección: Descripción de los primeros auxilios5.1. Medios de extinciónExtintor apropiado:anhídrido carbónico, espuma, polvo seco, sistema de agua pulverizada, sistema de agua atomizadaLos medios de extinción que no deben utilizarse por razones de seguridad:Chorro de agua a alta presión5.2. Peligros específicos derivados de la sustancia o la mezclaEn caso de incendio puede formarse cloro gas.5.3. Recomendaciones para el personal de lucha contra incendiosLlevar puesta protección respiratoria independiente del aire ambiente.Llevar el equipo de protección personal.6.1. Precauciones personales, equipo de protección y procedimientos de emergenciaEvitar el contacto con los ojos y la piel.Evitar la formación de polvo.Utilícese indumentaria de protección personal.6.2. Precauciones relativas al medio ambienteNo es necesario.6.3. Métodos y material de contención y de limpiezaAbsorción mecánicaEliminar el material contaminado como residuo, de acuerdo con la sección 13.6.4. Referencia a otras seccionesVer advertencia en la sección 8.7.1. Precauciones para una manipulación seguraAbrir y manipular el envase con cuidado.Evítese el contacto con los ojos y la piel.Medidas de higiene:No comer, beber ni fumar durante el trabajo.Lavarse las manos antes de las pausas y al finalizar el trabajo.7.2. Condiciones de almacenamiento seguro, incluidas posibles incompatibilidadesAlmacenar en lugar seco y fresco.Evitar estrictamente temperaturas por debajo de 0 °C y por encima de + 50 °C.No guardar junto a productos alimenticios7.3. Usos específicos finalesDeshumidificador8.1. Parámetros de controlLímites de Exposición OcupacionalVálido paraEspañaningunoDerived No-Effect Level (DNEL):Índice de exposición biológica:ninguno8.2. Controles de la exposición:Protección respiratoria:No es necesario.Protección manual:En el caso de un contacto prolongado se recomiendan guantes protectores de caucho nitrilo según la norma EN 374.tiempo de penetración > 480 minespesor del material > 0,1 mmEn el caso de contacto prolongado o repetido hay que tener en cuenta que los tiempos de penetración pueden ser en la práctica mucho más cortos que los determinados según EN 374. Se debe comprobar siempre que los guantes de protección son los adecuados para cada trabajo específico (por ejem. resistencia mecánica, témica, compatibilidad con el producto, efectos antiestáticos, etc.). Los guantes de protección deben ser sustituidos inmediatamente cuando aparecen los primeros signos de desgaste. Se tiene que tener siempre en cuenta tanto la información facilitada por el fabricante como la proveniente de la mutua de accidentes. Recomendamos trazar un plan de protección para las manos en colaboración con los fabricantes de guantes y las mutuas de accidentes.Protección ocular:Usar gafas de proteccion ajustadas.El equipo de protección ocular debería ser conforme a EN 166Protección corporal:Ropa de protección adecuadaLa ropa de protección debería ser conforme a EN 14605 para salpicaduras de líquidos o a la norma EN 13982, para polvo. Instrucciones sobre el equipo de protección personal:La información suministrada sobre equipos de protección individual se ofrece sólo como guía. Debe realizarse una valoración de riesgos total antes de utilizar este producto, con el fin de determinar cuáles son los equipos de protección más adecuados a las condiciones de trabajo. Los equipos de protección individual deben cumplir con la norma EN aplicable.9.1. Información sobre propiedades físicas y químicas básicasAspecto PastillassolidoAzul, BlancoOlor típicoUmbral olfativo No hay datos / No aplicablepH No hay datos / No aplicablePunto inicial de ebullición No disponiblePunto de inflamación No hay datos / No aplicableTemperatura de descomposición No hay datos / No aplicablePresión de vapor No hay datos / No aplicableDensidad No hay datos / No aplicableDensidad aparente No hay datos / No aplicableViscosidad No hay datos / No aplicableViscosidad (cinemática) No hay datos / No aplicablePropiedades explosivas No hay datos / No aplicableSolubleSolubilidad cualitativa(23 °C (73.4 °F); Disolvente: Agua)Temperatura de solidificación No hay datos / No aplicablePunto de fusión No disponibleInflamabilidad No hay datos / No aplicableTemperatura de auto-inflamación No hay datos / No aplicableLímites de explosividad No hay datos / No aplicableCoeficiente de reparto n-octanol/agua No hay datos / No aplicableTasa de evaporación No hay datos / No aplicableDensidad de vapor No hay datos / No aplicablePropiedades comburentes No hay datos / No aplicable9.2. Otros datosNo hay datos / No aplicable10.1. ReactividadA temperaturas superiores a 770ºC, se produce descomposición y desprendimiento de cloro.10.2. Estabilidad químicaEstable bajo las condiciones de almacenamiento recomendadas.10.3. Posibilidad de reacciones peligrosasVer sección reactividad10.4. Condiciones que deben evitarseNinguno conocido si se usa según lo dispuesto.10.5. Materiales incompatiblesVer sección reactividad.10.6. Productos de descomposición peligrososNinguno conocido11.1. Información sobre los efectos toxicológicosInformaciones generales toxicológicos:La mezcla está clasificada en base a la información de peligro disponible para los ingredientes tal y como se define en el criterio de clasificación para mezclas de cada clase de peligro o diferenciación en el Anexo I del Reglamento (CE) N° 1272/2008. Información de sanidad y ecológica relevante disponible para las sustancias listadas en la Sección 3 se proporciona a continuación.Irritación de los ojos:Provoca irritación ocular grave.Toxicidad oral aguda:Toxicidad inhalativa aguda:Toxicidad dermal aguda:Corrosión o irritación cutáneas:Lesiones o irritación ocular graves:Mutagenicidad en células germinales:Detalles generales de ecología:La mezcla está clasificada en base a la información de peligro disponible para los ingredientes tal y como se define en el criterio de clasificación para mezclas de cada clase de peligro o diferenciación en el Anexo I del Reglamento (CE) N° 1272/2008. Información de sanidad y ecológica relevante disponible para las sustancias listadas en la Sección 3 se proporciona a continuación.Ninguna12.1. Toxicidad12.2. Persistencia y degradabilidadNo hay datos.12.3. Potencial de bioacumulación / 12.4. Movilidad en el suelo No hay datos.12.5. Resultados de la valoración PBT y mPmB12.6. Otros efectos adversosNo hay datos.13.1. Métodos para el tratamiento de residuosEvacuación del producto:Eliminar residuos de acuerdo con la legislación localEvacuación del envase sucio:Reciclar los envases solo cuando estén completamente vacíos.Código de residuo06031414.1.Número ONUNo es un producto peligroso según RID, ADR, ADN, IMDG, IATA-DGR14.2.Designación oficial de transporte de las Naciones UnidasNo es un producto peligroso según RID, ADR, ADN, IMDG, IATA-DGR14.3.Clase(s) de peligro para el transporteNo es un producto peligroso según RID, ADR, ADN, IMDG, IATA-DGR14.4.Grupo de embalajeNo es un producto peligroso según RID, ADR, ADN, IMDG, IATA-DGR14.5.Peligros para el medio ambienteNo es un producto peligroso según RID, ADR, ADN, IMDG, IATA-DGR14.6.Precauciones particulares para los usuariosNo es un producto peligroso según RID, ADR, ADN, IMDG, IATA-DGR14.7.Transporte a granel con arreglo al anexo II del Convenio MARPOL y el Código IBCno aplicable15.1. Reglamentación y legislación en materia de seguridad, salud y medio ambiente específicas para la sustancia o la mezclaTenor VOC0 %(VOCV 814.018 VOC regulationCH)15.2. Evaluación de la seguridad químicaSe ha realizado una evaluación de seguridad química.El etiquetado del producto se indica en la sección 2. El texto completo de todas las abreviaturas indicadas por códigos en esta hoja de seguridad es el siguiente:H290 Puede ser corrosivo para los metales.H319 Provoca irritación ocular grave.Otra información:Ésta información se basa en el estado actual de nuestros conocimientos y se refiere al producto en la forma en que se suministra. Pretende describir nuestros productos bajo el punto de vista de los requisitos de seguridad y no pretende garantizar ninguna propiedad o característica particular.Los cambios relevantes en esta ficha de datos de seguridad están indicados por una línea vertical en la margen izquierda del texto. El texto correspondiente aparece en un color diferente y en campos sombreados.Los escenarios de exposición para el cloruro de calcio pueden descargarse en el siguiente enlace:/mymsds/.563455..en.ANNEX_DE.26270212.0.DE.pdf Adicionalmente, puede accederse a ellos en internet, , bajo el código 563455.。

摩恩 超滤净水器 UF1030 超滤净水器 UF1130 使用说明书

摩恩 超滤净水器 UF1030 超滤净水器 UF1130 使用说明书

尊敬的顾客:非常感谢您选用摩恩产品,本产品将在今后多年中为您提供可靠的服务。

每个摩恩产品均采用了高标准的材料和新的生产工艺技术,因而每个摩恩产品都具有极好的耐用性。

我们确信在今后多年中,您都可以享受摩恩产品为您带来的舒适和方便。

为了您的安装顺利,请仔细阅读这些指南。

摩恩服务热线:400-630-8866生产企业:摩恩(上海)厨卫有限公司地 址:中国(上海)自由贸易试验区富特北路399号注意事项1.为了保证本净水器的安全及正常使用,我公司在此郑重告知用户:产品必须由我公司授权的安装、维护服务商进行安装、维修,否则对因为安装、维修而导致的事故,我公司概不承担任何责任!2.本净水器为家庭用户设计,在其它场所使用请咨询服务热线或授权服务商。

3.本净水器的维护、滤芯更换请联系授权售后服务人员或咨询服务热线。

4.在对本净水器进行任何操作前,请仔细阅读和理解使用说明书。

5.净水器在运输、安装和使用中严禁倾斜。

6.切勿将净水器安装在阳光直射、雨淋或含有有害化学品的地方,或有掉落、被撞击等可能使本净水器受到损害的任何地方。

7.确保本净水器远离热源,不可将其接入热水管路上,不要试图把本机反向、倒置安装。

8.严禁将本净水器安装在可能受到冰冻的地方。

净水器温度使用范围为:5℃-38℃,当水温或环境环境温度低于5°C时,请关闭本净水器的供水管线(同时关闭快接三通阀),并排出净水器内的存水。

如果供水管线或净水器冻结,可能造供水管线或外壳的损坏,甚至破裂,影响使用。

9.工作压力:0.1~0.4MPa,使用过程中应保证压力不小于0.1MPa。

若进水水压超过0.4Mpa,必须加装减压阀(需另行购买)。

10.若超过3天不使用本净水器,再次使用前,需进行冲洗,冲洗过程中请勿取水饮用。

11.为保证出水水质,应及时更换滤芯。

各级滤芯使用期限应根据当地水质和用户要求,由专业人员完成更换。

12.定期检查净水器及水管配件看是否漏水,避免漏水给家中财物造成损失。

产品配置表格

产品配置表格
供电方式 待机电流 天线类型 安装方式 材质颜色 工作环境温湿度 阻燃等级
最大功耗 待机功耗 检测范围 报警值 检测气体类型 检测方式 频宽 通信距离 材质颜色 阻燃等级 安装方式
<25μA
CR2*1
<80mA
>70dB,3m
6
联网输出 /声光显示
PC,白色
UL94 V-2
(AC/DC适配器)
8.3uA
DC 3V DC 3V
电源参数 待机电流 检测功耗 供电方式 频宽 通信距离 材质颜色 级 光感范围 感应精度 安装方式
电源参数 待机电流 供电方式 水位高度 材质颜色 阻燃等级 安装方式
AC 110V240V,50/60Hz
待机功耗 检测范围 检测方式 频宽 通信距离 材质颜色 阻燃等级 安装方式
Max.3W 水平360°,前后>180°(手动) 5米内 最大支持Micro SD 32G 180° 1个(黑色,白色)、3个(白色)、6个 (蓝色)、不限(Plus) Wi-Fi PC+ABS,黑、白、蓝、白色Plus
25W ≤0.3W 300W阻性负载(白炽灯,卤素灯) 钢化玻璃、白色 UL94 V-0
DC 3V
待机电流 电池类型 报警电流 报警分贝 报警方式 材质颜色 阻燃等级
6V(4节AA电
待机功耗 扭力
池);DC 5V,1A 材质颜色
阻燃等级
100-240VAC 50/60Hz
100-240VAC 50/60Hz
DC 3V
待机功耗/Max功耗 报警分贝 材质颜色 阻燃等级 安装方式
待机功耗 Max 功耗 报警分贝 材质颜色 阻燃等级
SR单头顶发红外转发器_WBPW_I001
SR-ZTPWBPW-I001-01

RBK753 全家型三带无线网6系统说明书

RBK753 全家型三带无线网6系统说明书

Data SheetRBK753Whole Home Tri-band Mesh WiFi 6 SystemOverviewBreak free from limitations with strong,reliable, and lightning fast WiFi in every room of your home. From the top floor down to the basement, Orbi Tri-band Mesh WiFi 6 Systems bring you higher performance & simultaneous WiFi streaming, gaming & browsing on even more devices. This system includes NETGEAR Armor ™, advanced cyber security for your connected devices.Robust smart home WiFi.FeaturesCutting Edge Performance.Get the ultimate experience with 8 Streams of WiFi 6 a nd speeds up to 4.2Gbps.† Enjoy 4K/8K UHD streaming, l ag-free gaming & smooth streaming.It’s Easy.Enjoying your WiFi has never been easier. With the Orbi app, s et up your WiFi, customize your settings & enjoy your new O rbi WiFi in minutes.Gigabit Speeds Where You Need Them.Don’t let your home be a maze of dead zones. Get consistent speeds everywhere with Tri-band dedicated wireless backhaul & 8 Gigabit Ethernet ports.Cybersecurity With NETGEAR Armor ™.Protect your connected home devices from Internet threats with best-in-class anti-virus, anti-malware & data protection.1More Capacity, More Battery Life.Don’t be held back by limited capacity. Enjoy more devices simultaneously with 4X the capacity than before & improvedefficiency for longer battery life.Manage Your Kids’ Screen Time.NETGEAR Smart Parental Controls ™ let you easily manage your kids’ time online across their connected devices.2Data Sheet RBK753Whole Home Tri-band Mesh WiFi 6 SystemHouse DiagramRobustSmart Home ExperienceBuilt for Gigabit Internet Speeds EverywhereYou’ve paid for the fastest Internet speeds, now experience it everywhere in your home.Orbi AppUse the Orbi app to setup and manage your Orbi WiFi.NETGEAR Armor empowers you to eliminatevulnerabilities or simply know the status of your home network and devices, anytime, anywhere. Get instant notifications when malicious threats are detected, block unknown devices from joining your Orbi home network or take action on vulnerabilities as they are discovered easily through the Orbi App.Data SheetRBK753 Whole Home Tri-band Mesh WiFi 6 SystemOrbi Router (RBR750)Orbi Satellite (RBS750)Data Sheet RBK753Whole Home Tri-band Mesh WiFi 6 SystemWhat’s In the Box?• One (1) Orbi Router (RBR750)• Two (2) Orbi Satellites (RBS750)• One (1) 2m Ethernet cable• Three (3) 12V/2.5A power adapters • Quick start guideWhat Do I Need for Orbi to Work?• High-speed Internet connection• Connect to existing modem or gatewayTechnical Specifications• O rbi AX4200 Router & AX4200 Satellites (600 + 1200 + 2400Mbps)†• Simultaneous Tri-band WiFi - R adio 1: IEEE ® 802.11b/g/n/ax2.4GHz—1024-QAM support - R adio 2: IEEE ® 802.11a/n/ac/ax5GHz—1024-QAM support - R adio 3: IEEE ® 802.11a/n/ac/ax5GHz—1024-QAM supportPhysical Specifications• Dimensions: 9.1 x 7.2 x 2.8 in each • Weight: 1.9 lb eachSoftware Features• Orbi Mobile App• M U-MIMO capable for simultaneous data streaming • I mplicit & Explicit Beamforming for 2.4GHz & 5GHz bands• Processor - Router & Satellite - P owerful quad-core 1.4GHz processor • Memory – Router - 512MB NAND flash and 1GB RAM • Antenna – Router & Satellite (each) - S ix (6) high-performance internal antennas withhigh-power amplifiers • Ports – Orbi Router - T hree (3) 10/100/1000Mbps Gigabit EthernetLAN ports - O ne (1) 1Gbps Gigabit Ethernet WAN port • Ports – Orbi Satellite (each) - T wo (2) 10/100/1000Mbps Gigabit EthernetLAN ports • L ink aggregation using WAN port and a Gigabit Ethernet port • Security - C omprehensive anti-virus & data theftprotection for your PC, Mac ® and mobile devices with NETGEAR Armor ™-S tandards-based WiFi Security(802.11i, 128-bit AES encryption with PSK) - G uest WiFi Network is easy to setup separate &secure Internet access for guests • Voice Control - A mazon Alexa ™- The Google © Assistant • N ETGEAR Smart Parental Controls ™ — Manage your kids’ time online across their connected devices. Learn more at /spcThis product comes with a limited warranty that is valid only if purchased from a NETGEAR authorized reseller. /warranty *90-day complimentary technical support following purchase from a NETGEAR authorized reseller.‡Maximum wireless signal rate derived from IEEE 802.11 specifications. Actual data throughput and wireless coverage will vary and be lowered by network and environmental conditions, including network traffic volume, device limitations, and building construction. NETGEAR makes no representations or warranties about this product’s compatibility with future standards. Up to 4,200Mbps wireless speeds achieved when connecting to other 802.11ax 4,200Mbps devices. 1NETGEAR Armor ™ is free during the trial period. A yearly subscription, after the trial period, protects your connected devices. Visit /armor 2NETGEAR Smart Parental Controls™ fees apply for a Premium Plan. Visit /spc for more information. For regulatory compliance information, visit /about/regulatory For indoor use only.NETGEAR, the NETGEAR Logo, NETGEAR Armor, NETGEAR Smart Parental Controls, and Orbi are trademarks of NETGEAR, Inc. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Google Play and the Google Play logo are trademarks of Google LLC. Any other trademarks mentioned herein are for reference purposes only. © 2021 NETGEAR, Inc. NETGEAR, Inc. 350 E. Plumeria Drive, San Jose, CA 95134-1911 USA, /supportD-RBK753-3。

WHO《制药用水GMP指南》-2020草案(中英文对照版)

WHO《制药用水GMP指南》-2020草案(中英文对照版)

Working document QAS/20.842工作文件QAS/20.842May 2020二零二零年五月DRAFT WORKING DOCUMENT FOR COMMENTS:征求意见草案:Good manufacturing practices:优良制造规范(GMP):water for pharmaceutical use制药用水Background背景The control of water quality, including microbiological and chemical quality, throughout production, storage and distribution processes is a major concern. Unlike other product and process ingredients, water is usually drawn from an on-demand system and is not subject to testing and batch or lot release prior to use. The assurance of water quality to meet the on-demand expectation is, therefore, essential.水的制备、存贮和分配过程中对水质的控制,包括微生物和化学质量,是一个重要关注点。

与其它产品和工艺成分不同,水通常是来自一个按需运行的系统,在使用之前不会进行检测,也不会进行批放行,因此确保水质符合所需要求就至关重要了。

In recent years, following extensive consultation with stakeholders, several pharmacopoeias have adopted revised monographs on water for injection (WFI) that allow for production by non-distillation technologies, such as reverse osmosis (RO). In 2017, the World Health Organization (WHO) Expert Committee on Specifications for Pharmaceutical Preparations (ECSPP) recommended that the WHO Secretariat collect feedback on whether or not they should revise the WHO specifications and good manufacturing practices (GMP) on WFI, and how to do so. Following discussions during several consultations, the ECSPP agreed that the monograph in The International Pharmacopoeia (Water for injections) and the guideline WHO Good manufacturing practices: water for pharmaceutical use (1) should both be revised to allow for technologies other than distillation for the production of WFI. In early 2019, the WHO Secretariat commissioned the preparation of a draft guidance text for the production of WFI by means other than distillation. Following several public consultations, the text was presented to the Fifty-fourth ECSPP. The Expert Committee adopted the Production of water for injection by means other than distillation guideline and recommended that it should also be integrated into WHO’s existing guideline on Good manufacturing practices: water for pharmaceutical use.近年来,由于干系人提出非常多的建议,几部药典均对注射用水(WFI)进行了修订,允许采用非蒸馏技术如反渗透(RO)制备 WFI。

陶氏反渗透和纳滤膜技术手册2016版全解

陶氏反渗透和纳滤膜技术手册2016版全解
2-4.12陶氏FilmTec的解决方案–选用高有效面积膜元件降低投资和运行费用..................... 23
2-4.13陶氏苦咸水系列产品概述............................................................................................... 24
极低能耗反渗透元件
XLE-440极低能耗反渗透元件........................................................................................ 69
2-9陶氏FILMTEC™抗污染型反渗透元件
BW30-365-FR抗污染型反渗透元件............................................................................... 71
2-10陶氏FILMTEC™海水淡化反渗透元件
小型海水淡化反渗透元件
SW30-2514 SW30-2521 SW30-2540 SW30-4021 SW30-4040 ............Βιβλιοθήκη ...............77
TM陶氏化学公司或其附属公司的商标
目录-3
高脱盐率低能耗四英寸海水淡化反渗透元件
BW30-400-FR抗污染型反渗透元件............................................................................... 73
BW30-400/34i-FR端面自锁高产水量抗污染型苦咸水反渗透膜元件............................. 75

TDS说明书(2009.1)

TDS说明书(2009.1)

目录1企业介绍 (3)1.1企业组成: (3)1.2企业资质: (3)1.3企业精神: (3)1.4企业承诺: (3)2智能式低压电力电容器与传统无功补偿结构对比 (4)3TDS智能式低压电力电容器概述 (5)4TDS智能式低压电力电容器整机工作原理 (6)5TDS智能式低压电力电容器元部件特点 (7)5.1智能组件 (7)5.2基于微电子的TDS电磁式零投切复合开关电器 (7)5.3微型电流取样互感器 (7)5.4快速断路器 (7)5.5干式低压电力电容器 (8)6TDS智能式低压电力电容器应用案例 (8)6.1配电房低压无功补偿柜改造应用 (8)6.2杆上无功补偿箱应用 (8)6.3智能综合配电箱应用 (9)6.4新建配电房低压无功补偿柜 (9)6.5低压抽屉柜应用 (9)6.6美式箱变内应用 (10)7TDS智能式低压电力电容器型号分类技术参数 (10)7.1产品分类 (10)7.2容量规格 (11)7.3主要指标 (11)7.4人机联系 (13)7.5产品接线端子 (15)7.6配件-穿心式二次电流互感器TDS-120(如图14) (15)8TDS(GL)滤波式低压电力电容组合电器 (16)8.1产品特点与应用 (16)8.2整机工作原理 (16)8.3干式串联电抗器特点 (16)8.4产品分类 (17)8.5产品功能 (17)8.6产品技术指标 (17)8.7产品结构 (18)8.8产品机械安装 (18)8.9电气接线 (19)9TDS(KF)智能快速式低压电力电容器 (20)9.1产品特点与应用 (20)9.2产品型号 (21)9.3产品功能 (21)9.4产品技术指标 (22)9.5产品机械安装 (22)9.6电气接线 (22)10TDS-1821低压无功综合测控装置 (23)10.1产品概述 (23)10.2产品主要功能 (24)10.3产品主要指标 (25)10.4外形与安装尺寸 (25)11TDS-1622低压无功综合测控装置 (26)11.1产品外形与尺寸 (26)11.2主要功能 (26)12TDS-1531 配电综合测控装置(推荐与TDS(GL)滤波式电容器配合使用) (27)12.1产品外形与尺寸 (27)12.2主要功能 (27)13TDS产品资质文件 (28)13.1国家重点新产品证书 (28)13.2高新技术产品认定证书 (28)13.3100万次投切试验报告 (29)13.4TDS智能式低压电力电容器型式试验报告 (29)13.5TDS电磁式零投切复合开关电器试验报告 (30)13.6TDS(KF)智能快速式低压电力电容器型式试验报告 (30)13.7TDS(GL)智能滤波式低压电力电容组合电器型式试验报告 (31)13.8TDS低压无功综合测控装置CQC证书及型式试验报告 (31)14典型设计参考 (32)14.1混合补偿&RS485通信:TDS-C3智能电容器外接TDS-1821无功测控装置接线图 (32)14.2混合补偿&无线通信:TDS-C3智能电容器外接TDS-1821无功测控装置接线图 (33)14.3三相共补&RS485通信:TDS-C3智能电容器外接TDS-1821无功测控装置接线图 (34)14.4混合补偿&RS485通信:TDS(GL)滤波式电容器外接TDS-1821无功测控装置接线图 (35)14.5三相共补:TDS(GL)滤波式低压电容器外接TDS-1531配电综合测控装置接线图 (36)14.6混合补偿&RS485通信:TDS智能电容器+TDS快速式电容器外接TDS-1821测控装置接线图 (37)14.7三相共补:TDS-C3系列智能电容器外接TDS-1622无功综合测控装置接线图 (38)14.8混合补偿:TDS-C3系列智能电容器外接TDS-1622无功综合测控装置接线图 (39)14.9三相共补:TDS-C3智能式低压电容器无外接控制器接线图 (40)15TDS智能无功补偿快速选型表 (41)15.1TDS-1821&TDS-C3系列智能干式电容器(无线接口)混合补偿选型表(常规场合) (41)15.2TDS-1821&TDS(GL)系列智能滤波式电容器补偿选型表 (42)15.3TDS-1821&TDS(KF)智能快速式电容器&常规式混合配置选型表(适合无功快速变化场合).43 16部分运行业绩 (44)1企业介绍1.1 企业组成:·南通现代电力科技有限公司·江苏现代电力电容器有限公司·南通现代电力科学研究所·现代电力无功工程技术研究中心南通现代电力科学研究所成立于1993年12月,其后相继成立南通现代电力科技有限公司、江苏现代电力电容器有限公司、现代电力无功工程技术研究中心。

Filtration Products BECO PROTECT PP Pure 深层滤芯技术数据表

Filtration Products BECO PROTECT PP Pure 深层滤芯技术数据表

技术数据表深层过滤BECO PROTECT® PP Pure深层滤芯液体食品、化妆品、精细化学品以及工艺用水的粗滤和精滤。

由于采用褶皱型聚丙烯过滤材料,因此该深层滤芯具有很高的流量。

特性和优点-采用褶状聚丙烯过滤材料,过滤面积大且有效。

-过滤效率高,针对要求的过滤精度,其过滤效率ß系数≥5000 相当于截留率≥99.98%。

-由于使用 100% 的聚丙烯,化学耐受性高。

滤芯的设计BECO PROTECT PP Pure 深滤芯采用优质的褶状聚丙烯无纺布制造而成。

所使用的所有材料都确保过滤过程对产品没有影响,不会导致吸附或微粒迁移。

材料合成材料部件符合10/2011/EC规范及其补充规定的要求。

所有应用的原材料符合FDA 21 CFR第177.1520条的规范要求。

技术参数流量水温为20°C 条件下的10" (250mm)滤芯(典型值)滤芯型号/分离精度PPPB60.6 PPP01 1.2PPP033.0 PPP05 5.0 PPP10 10.0连接件编码单头开 2-222 O 型圈无定心顶尖单头开2-222 O 型圈 3层卡口连接件 带定心顶尖单头开2-226 O 型圈 2 层卡口连接件 带定心顶尖订购信息BECO PROTECT PP Pure深层滤芯保护膜包装存放于纸箱中。

PPP B6 = 0.6µm0 = 编码0 (SOE)* 1 = 10" (250mm)S = 硅酮01 = 1.2µm 2 = 编码2 (SOE)* 2 = 20" (500mm)*V* = 含氟弹性体03 = 3.0µm7 = 编码7 (SOE) 3 = 30" (750mm)05 = 5.0µm 4 = 40" (1000mm)*07 = 7.0µm10 = 10.0µm* 应索提供示例PPP B67 1 SBECO PROTECT PP Pure深层滤芯;分离精度0.6µm;编码7,10" (250mm),硅酮密封消毒蒸汽消毒BECO PROTECT PP Pure深层滤芯可最高121°C蒸汽灭菌或者高压灭菌。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档
最新文档