Release Note

合集下载

releasenotes

releasenotes

Release notesOffboard Diagnostic Information System ServiceRelease 3.0.0 (1)New functions (1)Resolved system defects (2)Vehicle restrictions (2)Supported vehicle models (2)This chapter contains the supported vehicle models (2)Supported AUDI-Models (2)Supported Volkswagen-Models (2)Supported Volkswagen Nutzfahrzeuge-Models (2)Supported Seat-Models (2)Supported Skoda-Models (2)Supported Bentley-Models (2)Supported Lamborghini-Models (2)Release 3.0.0This release is a new base version with new functions. It has to be installed via SingleSetup.New functions•ODIS Service SingleSetup does not install Adobe Reader.•ODIS Service SingleSetup does not install Virtual Keyboard.•Support of diagnostic interface VAS6154.•It is possible to flash an old ECU software version.•Display of ECU flashability in self-diagnosis is improved.•The contents of the diagnostic protocol are extended.•Support requests contain hardware and software version of tester PC.•Order number is used for diagnostic protocol and diagnostic session filenames.•Improved manual variant identification.•Display of names of teststeps can be switched off in GFF..•Stabilization of GFF hotfix mechanism.•Diagnostic adresses of ECUs are shown with four digts.•Improvemed access to self-diagnosis functions.•New hardware configuration manager for VAS5054/VAS5055.•Disclaimer changed.•Changes in ODIS Service update process•Display of TSB tree without DISS coding.•Support requests may be stored.•Display of connection type for diagnostic hardware.•Support of Internet Explorer 11.Resolved system defects•Search in Measured Value Tables did not work correctly.•Increased occurence of error 4009E•Some immobilizers could not be adapted.•Missing timestamp when sending support request in diagnostic protocol Vehicle restrictions•For brand AUDI, the Flash mode is supported.•For brand Volkswagen PKW, the Flash mode is restricted. The usage is only allowed if described in technical bulletins.•Flash mode is not supported for all other brands.•Only immobilizer components are diagnosable in LT2 vehicles.Supported vehicle modelsThis chapter contains the supported vehicle modelsSupported AUDI-Models•All AUDI vehicle models are supported.Supported Volkswagen-Models•All Volkswagen vehicle models are supported.Supported Volkswagen Nutzfahrzeuge-Models•2K - Caddy 2004 >•7H/7J - Transporter 2004 >•2C - Caddy 2011 >•7E/7F - Transporter 2010 >•2H - Amarok 2010 >•2E/2F - Crafter 2006-2015 >Supported Seat-Models•All Seat vehicle models are supported.Supported Skoda-Models•All Skoda vehicle models are supported.Supported Bentley-Models•All Bentley vehicle models are supported.Supported Lamborghini-Models•All Lamborghini vehicle models are supported.。

ReleaseNotes

ReleaseNotes
1. 修复了部分导致崩溃的bug
5.6
1. 新增公会资料卡,显示公会图集和公会论坛最新内容
2. YY会员可以向好友展示专属皮肤
3. 应用区新增“图歪歪”功能
4. 系统托盘区增加在线状态更改
5.5
1. 新增YY会员专属皮肤
5.4
1. 主界面应用TAB支持自定义功能
2. 支持应用飞机票功能
3.新增手机YY用户在线马甲显示
4.优化主界面换肤功能
4.5
1.新增频道飞机票支持复制粘贴功能
2.IM新增禁止传文件、举报功能
4.4
1.新增YY会员功能,会员红名显示
2.增加YY会员专用表情包
3.优化频道导入群功能
4.频道飞机票样式更新
5.恢复公告插入视频/图片的积分限制
3. 优化创建子频道时直接设置模版功能
4. 游戏组队增加导航功能
5. 新增YY彩票应用
6.2
1. 上麦名片支持多张轮播显示
2. 精彩世界新增纯语音分类
3. 优化频道和推荐体验
6.1
1. YY精彩世界增加视频全屏和视频自适应窗口尺寸
2. 解决群消息重复收取问题
3. 聊天窗口增加游戏卡片链接
3.新增频道麦克风开关快捷键
4.9
1.优化音量条操作和显示效果
2.优化发言状态显示
3.增加“绑手机可发公屏消息”可选项
4.优化飞机票读取状态
5.新增会员炫铃功能
4.8
1.新增表情导入导出Βιβλιοθήκη 能 2.新增断网消息保护机制
3.优化登录时的操作体验
4.优化托盘图标消息提取操作便利性

标杆的神器 V1.0.5 ReleaseNote

标杆的神器 V1.0.5 ReleaseNote
【2014】033号- 关于H3C S5830V2 24S交换机R2311系列版本使能burst-mode enable会导致设备无法被ping通的公告
【2014】034号-关于H3C SR8800-X(-S)CR16000-F SR8800-F系列路由器内存泄露导致PPPOE拨号失败问题公告
3、修复其他问题(共计10个)。
********************************************************************
2015-1-12 发布V1.0.4版本
==========================================
新增功能
----------------------
1.新增需求
(1)【标杆的神器】可以进行蓝小翔皮肤的切换。
(2)【工具宝箱】支持对H3C命令行的模糊查询。
(3)【工具宝箱】常用协议查询,调整为常用协议号查询。
(4)【控制台】支持V7设备及用户名缺省情况下设备的自动登录。
(5)【控制台】支持设备管理员权限的自动登录。
【2014】044号-关于H3C S6300-42QT加载R2311到R2311P03版本会反复升级逻辑无法启动的公告
【2014】045号-关于H3C S5820V2-52QF-U从R2307版本升级到R2311P04导致设备无法启动问题的公告
【2014】046号-关于MSR使用3G模块导致内存泄露的公告
(8)【维护大全】支持对V7设备的安全配置审查(支持对debug开关的检查)。
2、新增故障排查脚本:
01公共协议-1.5 BGP MPLS问题排查流程
修正缺陷

RELEASE_NOTES

RELEASE_NOTES
The LE product does not support VHDL. However, it does support Verilog
and SystemC.
This release includes a new dongle driver installer for Windows.
No one is permitted to use these Marks without the prior written consent
of Mentor Graphics or the respective third-party owner. The use herein
Installation and Licensing Guide under the section Supported Platforms.
* PRODUCT SUPPORT
The profiling feature is now supported on the linux_x86_64 platform.
The new dongle driver versions that will be installed are as follows:
+ Aladdin (FLEXID=9-) driver version 4.96
+ Dallas (FLEXID=8-) driver version 3.2.1.11
* PLATFORM AND COMPILER SUPPORT
SystemC has dependencies on C++ compiler versions. In release 6.5, the
Solaris and Windows MinGW versions of gcc 3 compilers will be replaced

TH LINK PROFIBUS 6.1.2.0 Release Note说明书

TH LINK PROFIBUS 6.1.2.0 Release Note说明书

Release Note TH LINK PROFIBUSVersion 6.1.2.01. Components of the current product version2. Manuals of product version3. System requirementsFor configuration of TH LINK and use of TH SCOPE easy the following system requirements have to be fulfilled:3.1. Network1 free IP addressenablement of the following ports3.2. SoftwareWeb browser with Adobe Flash player 10.0 or higher Adobe Reader 8 or higher to read documentation4. Scope of deliveryThe scope of delivery includes:TH LINK Installation Guide Release Note5. Installation instructionPlease read the installation guide before installing the TH LINK.6. CompatibilityThe TH LINK is compatible with the following products.7. Mean Time Between FailuresThe MTBF value is 701,543 hours ≙ about 80 years.8. New and changed functionsNew functionsThe following communication processors can be detected and displayed on the net-work overview by TH LINK PROFIBUS.Changed functionsNone9. Bug FixesNone10. Notes and known problemsData that cannot be queried from the device because the device does not provide them are displayed with “n.a.” for "not available".Data that cannot be determined are not incorporated in the calculation of sums.Redundant master is displayed incorrect in the Live List.The assumed computer system time varies about 3 minutes after 1 week.11. HistoryNew functionsTH SCOPE can find the TH LINK in networks where multicast communication is notpermitted. There is a new configuration page to make the respective settings, so that the communication with the TH LINKs can be done via unicast.Further information you can find in the TH SCOPE user manual.Bug FixesTH LINK PROFIBUS displayed TH LINK PROFINET wrongfully as failed.Slave ID was displayed decimal instead of hexadecimal.New functionsDisplay of the number of diagnostics in the Error statisticsFiltering of dataHide/show table columnsChanged functionsNavigation in the navigation tree is possible to the second level. The information of the views from the third and fourth level are integrated in the inventory.Master list, Slave list and module list were deleted and the information was integrated in the inventory.Device type, device ID and vendor are included in inventory.Time synchronisation: When the measurement is started without a valid time server or taken over computer system time, all diagnostics will be displayed with a time stampof 1970. If a computer system time is taken over later, all previously occurred diagnos-tics will be recalculated to the correct date.Bug FixesIn some cases failures were displayed, although no failures occurred.Changed functionsTime stamp: When the measurement is started without a valid time server or takenover computer system time, all diagnostics will be displayed with a time stamp of1970. Even if these settings will be changed later, the date for the previously occurred diagnostics remains unchanged.Bugs fixesThe buttons “Test” and “Synchronize” were not disabled when changes in the timeserver settings have been made.The type of measurement could not be change to “Stop if buffer full”.The navigation from TH LINK (Ethernet-PROFIBUS 10003006) to TH LINK (Ethernet-PROFINET/Industrial Ethernet 10003007) was not possible.If more than one master has been identified, in the bus statistics the legend under the chart was not displayed completely.When you load the web page, the error message 2032 was displayed.New and changed functionsPerformance improvements for trend analysisNew and changed functionsConnection between higher-level network and field levelAccess to the PROFIBUS networkAccess protection through integrated user administrationBasis for TH SCOPE, PROFIBUS Scope, Trebing + Himstedt, DTM Library, TACCand TH OPC Server DPTH SCOPE easy preinstalled12. Frequently asked questionsAccessQ: How many people can access the TH LINK via web at the same time?A: Up to six people can access on the TH LINK simultaneously. Once a person logs onto the TH LINK as an administrator, no one else can access it.Time displayQ: I selected Yes in Use time server, but I always get a time stamp of the year 1970. Why is that so?A: It may be that the time server you set is not available from your network. Below the time server setting there is a possibility to test the set time server by clicking on the respective button. If no current date is displayed, please check your settings. If there is no time server available from your network, you have the possibility to take over the computer system time by selecting No for Use time server. Then click on the button Synchronize.Time server settingsQ: Is it possible to use the server name instead of IP address for time server settings?A: Yes, you can use server names. Make sure that a DNS server is set up and that it is available.DPV1 and MPI masterQ: The adjusted baud rate is detected correctly, but there is no master displayed. Why is that so?A: The master is not shown because there has not been reference data exchange with the other stations.SlaveQ: Why are my slaves displayed as failed although they are working properly?A: Check if you have changed the station addresses of the slaves. If you change addresses (station addresses as well as TH LINK IP addresses) you have to restart the TH SCOPE measurement so that the new network structure is detected.Q: What does failure of a slave mean in the failure statistics?A: In the failure statistics a slave is counted as failed if the slave cannot provide I/O data for the master.Q: Why does the HEX code of the manufacturer specific diagnostics not match with the entry in the vendor manual?A: The first byte of the manufacturer specific diagnostics is already decoded in TH SCOPE easy and displayed as “manufacturer specific diagnostics.13. Approval。

ReleaseNote_cn

ReleaseNote_cn

E a s y B u i l d e r8000R e l e a s e N o t e[EB8000 版本命名规则]例如:EB8000 V.2.0.0第一位数 : 表示此版本所建立或开启过的工程档案,无法再使用旧版本开启第二位数 : 表示有新功能或新Driver开发第三位数 : 表示有修正BugsVersion 3.4.5 2010/4/28[新增功能]1. 更换PLC类型时, 对象会自动选择相同名称的装置类型(device type)2. 下载对话窗提供自动下载功能, EB8000在储存工程档案,并直接按下”下载”按键后,可以使用上一次的下载位置自动下载档案[修正功能]1. 修正MACRO中的函数若与GetData与SetData函数共享变量, 可能无法正常执行。

例如下面的使用例子:GetData(a, “PLC”, X, 0, 1)HIBYTE(a, b)此时变量b可能无法得到正确的运算结果2. 修正系统保留地址LB11960~11967无法在系统接收到干扰讯号时, 禁止”PLC NoResponse”窗口的出现3. 修正当某一站号的PLC无法通讯时, 会导致使用站号变量的对象也无法通讯4. 修正MACRO的sub function无法正确传送变量类型的参数, 例如在使用sub int func(char a, short b, short c), a得直无法被正确传递5. 修正MACRO的select case语法, 无法连续使用case-case, 例如下面例子的case 1与case2连续使用select case acase1case2b = 20breakcase3b = 30breakcase elseb = 50end select6. 修正MACR的INPORT函数INPORT(data[0], “Free Protocol”, 10, return_value)当发生timeout时, return_value将记录实际读取的byte数目, data也将存放读取的内容7. 修正在使用“Find”功能时若点击搜寻结果, 无法开启页面编号超过255的页面8. 修正使用备份对象时, 若备份动作尚未完成即拔除USD碟, 可能导致下一次无法进行备份动作9. 修正XY Plot的标示(Maker)无法使用绘点模式(Point)10. 修正 Direct Window的触发模式当选择使用”OFF”时, 在换页时可能无法消除已出现的Direct Window11. 修正当数据取样(Data Log)的清除功能(Clear)与趋势图的暂停功能(Hold)同时被触发使用时,可能造成趋势图不正常显示[新增驱动程序]1. 新增MITSUBISHI AJ 71 (Format 4)驱动程序2. 新增MODBUS RTU (0x/1x Range Adjustable) 驱动程序, 可以设定0x/1x的地址范围, 避免读写命令超出PLC允许读写的地址[驱动程序修改]1. 修正GE Fanuc 90-30驱动程序无法读取超过255的Bit地址2. PANASONIC FP 驱动程序新增FL, DT地址类型3. LS GLOFA Cnet驱动程序的IX, QX的bit地址范围修正为0~63Version 3.4.4a 2010/4/11[修正功能]12. 新增MITSUBISHI AJ 71 (Format 4)驱动程序13. 新增MODBUS RTU (0x/1x Range Adjustable) 驱动程序, 可以设定0x/1x的地址范围, 避免读写命令超出PLC允许读写的地址14. 修正GE Fanuc 90-30驱动程序无法读取超过255的Bit地址15. 修正系统保留地址LB11960~11967无法在系统接收到干扰讯号时, 禁止”PLC NoResponse”窗口的出现16. 修正当某一站号的PLC无法通讯时, 会导致使用站号变量的对象也无法通讯17. 修正MACR的INPORT函数INPORT(data[0], “Free Protocol”, 10, return_value)当发生timeout时, return_value将记录实际读取的byte数目, data也将存放读取的内容Version 3.4.4 2010/4/7[修正功能]1. 修正宏指令的数值运算无法正确操作属于char型态的变量2. 修正宏指令的浮点数运算3. 修正使用Master-Slave模式时, Master端在与PLC断线并重新连结时, Slave端无法与Master端恢复通讯4. 修正当宏指令中使用过多非ASCII字符的注释时, 有时无法正确执行反编译功能5. 修正使用Office 2007所产生的EXCEL档案无法汇入到文字库(Label Library)与Event Log中[驱动程序修改]3. 修正YASKAWA SMC 3010(Ethernet)驱动程序, 新增D_array, R_array, D_arr_bit地址类型4. 修正YASKAWA SMC 3010驱动程序, 新增D_array, R_array, D_arr_bit地址类型Version 3.4.3 2010/3/30[修正功能]6.修正宏指令的SetData函数无法一次传送超过256 words的数据7.修正宏指令的数学运算功能无法计算超过20000000的数值8.修正Memory Map协议无法同时处理master与slave模式9.修正PLC控制对象的打印功能无法使用远程备份/打印服务器10.修正数据传输(Data Transfer)无法传送数据到远程HMI11.使用S7-300 MPI driver 时, 无法同时使用CP343 Ethernet 装置12.宏指令有时使用中文注释会造成内容混亂13.三菱FX 3U 驱动程序加上噪声过濾功能14.修正EasyConverter.exe 无法正确转换超过99999 的數值[新增功能]1.宏指令新增select命令的通讯速度支持1200与2400 baud rate[驱动程序修改]5.修正OMRON_CJ1驱动程序无法读取EM地址6.修正HITACHI Series驱动程序无法读写Y地址Version 3.4.2 2010/3/18[修正功能]1.HMI长时间的运作可能出现的黑屏问题2.Data transfer对象如果传递远程PLC上的数据到本地HMI上, 可能出现黑屏的问题3.修正PLC Control的hardcopy无法使用的问题4.修正在向量图库的圆形无法完整显示的问题[新增驱动程序]1. Panasonic FP2 (Ethernet)FP2+ET1网络模块Version 3.4.1 2010/3/4[新增功能]3. 宏指令支持select-case语法, 下面为简单的使用范例select case acase1b = 10breakcase2b = 20breakcase elseb = 50end selectselect-case的用法必须使用 select case作为起始, 接着连接一个变量, 用来判断哪个条件式成立, 最后使用end select作为结尾, 如下:select case [variable][条件式 1][条件式 2]…..[条件式 n]case else…. // 当所有的条件式皆不成立时, 将执行此处的内容breakend select[条件式]使用case当起始, 接着连接一个常数, 最后使用case当结尾, 如下:case [constant][执行内容]break当[variable]等于[constant]时, 将执行该[条件式]下的[执行内容]当[variable]不等于所有的[constant]时, 将执行case else中的[执行内容]以上面的例子而言, 当a等于1时, b将等于10;当a等于2时, b将等于20;当a既不等于1也不等于2时, 将执行case else中的内容, 也就是b将等于504. 宏指令的HIIBYTE, LOBYTE, HIWORD, LOWORD, SQRT等数学运算函数支持使用array变量, 例如:for i = 0 to 10HIBYTE(a[i], b[i])next[修正功能]15. 修正当装置断线并重连后, 宏指令的INPORT函数无法正常使用16. 修正在某些情况下因装置断线而导致HMI的运行不正常17. 修正SIEMENS S7/300 MPI驱动程序无法支持主从协议[驱动程序修改]7. MITSUBISHI_FX3U驱动程序新增Z地址类型8. 修正恢复MITSUBISHI_FX3U驱动和X系列人机通讯9. 修改SCHLEICHER XCS 20C的地址类型排列顺序10. 修正OMRON CJ1 Ethernet驱动无法连接多台人机11. 修正KOYO CLICK 无法正确读写DD与DF地址12. 修正Panasonic FP (Ethernet) AFPX_COM5无法通讯13. MITSUBISHI AJ71 driver配合A CPU修正protocol.Version 3.4.0 2010/2/10[新增功能]1. 宏指令新增PURGE命令, 用来清除 COM端口中的数据2. 新增LW9576, 用来累积MODBUS TCP/IP Server收到的资料数目3. MODBUS Server可以设定使用[Turn around delay]4. [文字卷标库]提供排序功能5. 用户可以选择工程档案所需使用的语言数目当语言数目小于8时, 对象的文字卷标如果选用多国语言功能时, 对象的状态数可以设定超过32 (在 EB8000中, 对象所使用的语言数目乘上状态个数不得超过256)6. 对象的文字卷标提供[Bitmap font]选项, 可以用来显示波斯文等特殊字体, 或是改善小字型文字的显示效果, 或是显示原来HMI不支持显示的字型7. [事件登录]对话窗提供”插入”(insert), “复制”(copy), “贴上”(paste)等功能, 也提供排序功能和右键功能选单8. 对象若勾选使用系统缓存器, 如果使用多重复制功能时,地址将自动自动累加9. Trend Display对象可以自由选择要显示的信道(channel)10. 在[系统设定]的[密码](Security)设定页中, 新增工程档案密码保护功能当工程档案设定使用此功能时, 在开启档案前需先输入正确的密码, 档案才能被开启。

TrueTest v1.02 Release Note (bcore-srn-046Pb)

TrueTest v1.02 Release Note (bcore-srn-046Pb)

_äìÉ`çêÉ» TrueTest™ v1.02 Release NoteJanuary 2005CSR Churchill House Cambridge Business Park Cowley Road Cambridge CB4 0WZ United Kingdom Registered in England 3665875 Tel: +44 (0)1223 692000 Fax: +44 (0)1223 692001 © Cambridge Silicon Radio Limited 2002-2005 This material is subject to CSR’s non-disclosure agreement.bcore-srn-046PbContentsContents1 2 Introduction .................................................................................................................................................... 3 1.1 Purpose ................................................................................................................................................... 3 Target Platforms ............................................................................................................................................ 4 2.1 Host 3 4 5 6 ..................................................................................................................................................... 4 2.2 Target Devices ........................................................................................................................................ 4 Software Components ................................................................................................................................... 5 Functional Changes Since TrueTest v1.01 .................................................................................................. 6 Known Issues................................................................................................................................................. 7 Testing ............................................................................................................................................................ 8_äìÉ`çêÉ™ TrueTest™ v1.02 Release NoteAcronyms and Definitions.................................................................................................................................... 9 Record of Changes ............................................................................................................................................. 10bcore-srn-046Pb© Cambridge Silicon Radio Limited 2002-2005 This material is subject to CSR’s non-disclosure agreement.Page 2 of 10Introduction1IntroductionTrueTest™ is a software development kit (SDK) for use in production test environments. It consists of the necessary libraries and documentation to enable customers to quickly and easily develop applications for testing _äìÉ`çêÉ» functionality suited to their own production test environment. It is possible to write TrueTest applications in a variety of languages including C/C++, Visual Basic and Delphi, and to connect to BlueCore devices via a number of different transports including BCSP, H4, USB and SPI. The TestEngine and TestFlash components were previously distributed as part of BlueSuite™. These components were last released in BlueSuite v1.20._äìÉ`çêÉ™ TrueTest™ v1.02 Release Note1.1PurposeThis document describes software release TrueTest v1.02 for CSR’s BlueCore Bluetooth® chips.bcore-srn-046Pb© Cambridge Silicon Radio Limited 2002-2005 This material is subject to CSR’s non-disclosure agreement.Page 3 of 10Target Platforms22.1Target PlatformsHostThe software is designed to run on the following Windows ® 32 platforms:! !Windows 2000 Windows XP Home + ProfessionalDepending on the method used, connection to BlueCore devices will require the use of a parallel, serial or USB port._äìÉ`çêÉ™ TrueTest™ v1.02 Release Note2.2Target DevicesThe release runs with all previously released versions of the BlueCore chip and all firmware releases, although some functions present in the API may not be supported by some firmware releases.bcore-srn-046Pb© Cambridge Silicon Radio Limited 2002-2005 This material is subject to CSR’s non-disclosure agreement.Page 4 of 10Software Components3! ! ! !Software ComponentsE2Api: API for programming I2C EEPROM devices via SPI TestFlash: API for programming flash devices via SPI TestEngine: API for running radio tests, accessing Persistent Store and running simple dm/hci commands via BCSP, H4, USB or (with limited commands) SPI. Supporting libraries: pshelp, spi, spicommon, spifns, spilptThis release is comprised of the following software components:The SDK is distributed as a .zip file, available on request and via . The structure of the release is as follows: TrueTest Drivers (drivers required for creating a connection) install.bat csrbc01.sys parspi.sys csrbc01.inf Help (help documentation for each API) E2Api.chm TestEngine.chm TestFlash.chm Include (C/C++ header files) Delphi (Delphi function declaration units) E2Api.pas TestEngine.pas TestFlash.pas VB6 (Visual Basic 6 function declarations) E2Api.bas TestEngine.bas TestFlash.bas VB7 (Visual Basic 7 (.NET) function declarations) E2Api.vb TestEngine.vb TestFlash.vb E2api.h TestEngine.h TestFlash.h Lib (C/C++ import libraries) E2Api.lib TestEngine.lib TestFlash.lib E2Api.dll TestFlash.dll TestEngine.dll pshelp.dll spi.dll spicommon.dll spifns.dll spilpt.dll_äìÉ`çêÉ™ TrueTest™ v1.02 Release Notebcore-srn-046Pb© Cambridge Silicon Radio Limited 2002-2005 This material is subject to CSR’s non-disclosure agreement.Page 5 of 10Functional Changes Since TrueTest v1.014Functional Changes Since TrueTest v1.01ID B-2515 B-2999 B-3087 Description The TestEngine module now contains functions for performing ACL data transmission of files and arbitrary byte arrays. See hciSendAclData and hciSendAclFile in the TestEngine API help file. TestEngine commands now work correctly over a H4 connection after a bccmdColdReset function has been issued. All TestEngine radiotest functions that generate HQ traffic now return TE_UNSUPPORTED_FUNCTION when called over a SPI connection as HQ messages cannot be received over SPI. Five new functions have been added to the TestEngine API to support configuration of the battery charger for BlueCore3-Flash. The functions are: bccmdBc3BuckReg; bccmdBc3Led0; bccmdBc3Led1; bccmdBc3MicEn; and bccmdBc3PsuTrim. See the TestEngine API help file for more information. BCCMD functions in TestEngine no longer return an incorrect value of success when they fail. A new function has been added to TestFlash, flStopProcessor, to stop the XAP processor over SPI connection. A number of functions have been added to the TestEngine API to allow encrypted connections to be set up. The added functions are used to execute HCI commands and wait for specific HCI events. The functions are hciCreateConnectionNoWait; hciLinkKeyRequestNegativeReply; hciPinCodeRequestReply; hciSetConnectionEncryption; hciWaitForConnectionComplete; hciWaitForEncryptionChange; hciWaitForLinkKeyRequest; and hciWaitForPinCodeRequest. A new function - bccmdRouteClock - has been added to route the external clock to the AIO1 pin. This will require firmware that supports the BCCMD_ROUTE_CLOCK PDU. The hciCreateScoConnection function was incorrectly returning the connection handle from the previous ACL connection instead of the SCO connection that it had just made. This caused hciDisconnect to pull down the ACL connection when given the handle returned by hciCreateScoConnection. The radiotestTxstart function within the TestEngine module returned an incorrect status when called with firmware which does not contain the radiotest module. A new function, radiotestStereoCodecLB, has been added to the TestEngine module. This function can be used to enable loopback mode of the stereo CODEC on supported devices.This section lists the functional changes since the release of TrueTest v1.01._äìÉ`çêÉ™ TrueTest™ v1.02 Release NoteB-3762 B-3846 B-3991B-4212B-4621B-5091B-5148 B-5151bcore-srn-046Pb© Cambridge Silicon Radio Limited 2002-2005 This material is subject to CSR’s non-disclosure agreement.Page 6 of 10Known Issues5Known IssuesID B-2553 Description The e2CheckSize function in E2Api does not take account of devices that ignore address bits out of the address range of the device. This may cause the function to report a device's size as valid, even if it is smaller than specified.The following issues are known and unresolved at the time of release._äìÉ`çêÉ™ TrueTest™ v1.02 Release Notebcore-srn-046Pb© Cambridge Silicon Radio Limited 2002-2005 This material is subject to CSR’s non-disclosure agreement.Page 7 of 10Testing6! !TestingWindows® 2000 Windows XP ProfessionalThe software has been tested in the following environments:Testing was performed with the following firmware builds:! ! ! ! !BlueCore2-ROM: 4Mb RFCOMM (1493) BlueCore-External: 8Mb Unified (1591)_äìÉ`çêÉ™ TrueTest™ v1.02 Release NoteBlueCore2-Flash Plug-n-Go: 8Mb Unified (1773) BlueCore3-Multimedia: 8Mb Unified (1592) BlueCore3-ROM: 6Mb Unified (1595)Testing of the TrueTest libraries was performed with a set of Visual Basic v7.0 (.NET) test scripts. These exercised approximately 80% of the functions provided in the SDK. This also tested the VB7 declarations provided with the SDK.bcore-srn-046Pb© Cambridge Silicon Radio Limited 2002-2005 This material is subject to CSR’s non-disclosure agreement.Page 8 of 10Acronyms and DefinitionsAcronyms and DefinitionsACL API BCSP BlueCore™ BlueSuite™ Bluetooth® Casira™ CSR dm EEPROM H4 HCI Persistent Store SDK SPI UART USB VB Asynchronous Connection-Less Application Programming Interface. Set of functions with documentation for building software applications. BlueCore Serial Protocol;CSR-defined protocol for communicating with BlueCore devices over a UART link Group term for CSR’s range of Bluetooth chips Suite of development tools that contains all of the BlueCore utilities Set of technologies providing digital audio and data transfer over short-range radio connections_äìÉ`çêÉ™ TrueTest™ v1.02 Release NoteCSR’s main Bluetooth evaluation hardware Cambridge Silicon Radio Device Manager Electrically Erasable Programmable Read Only Memory UART HCI transport Host Controller Interface Storage of BlueCore’s configuration values in non-volatile memory Software Development Kit; set of software libraries and documentation for an developing application Serial Peripheral Interface; Three-wire serial interface Universal Asynchronous Receiver Transmitter Universal Serial Bus Microsoft® Visual Basic®bcore-srn-046Pb© Cambridge Silicon Radio Limited 2002-2005 This material is subject to CSR’s non-disclosure agreement.Page 9 of 10Record of ChangesRecord of ChangesDate 02 JUL 04 11 JAN 05 Revision a b Reason for Change Original publication of this document. (CSR reference: bcore-srn-046Pa) Updated functionality and bug fixes. (CSR reference: bcore-srn-046Pb)_äìÉ`çêÉ™ TrueTest™ v1.02 Release Note_äìÉ`çêÉ»= TrueTest™ v1.02 Release Notebcore-srn-046Pb January 2005® Bluetooth and the Bluetooth logos are trademarks owned by Bluetooth SIG, Inc. and licensed to CSR._äìÉ`çêÉ™ is a trademark of CSR. All other product, service and company names are trademarks, registered trademarks or service marks of their respective owners.CSR’s products are not authorised for use in life-support or safety-critical applications.© Cambridge Silicon Radio Limited 2002-2005 This material is subject to CSR’s non-disclosure agreement.bcore-srn-046PbPage 10 of 10。

Moxa CP-104UL 104JU Series PComm Lite Release Note

Moxa CP-104UL 104JU Series PComm Lite Release Note

Utility for CP-104UL/104JU Series (PComm Lite) Release Notes Supported Operating SystemsNotesChangesApplicable ProductsBugs Fixed• Different versions of PComm Lite 2000 can be installed on the same PC.• Performance Analyzer can store previous configurations of the COM port list.• PComm Terminal users can set history depth in ANSI and VT100 mode.• PComm Terminal could not locate system file ws2_32.dll in Windows 2000 and Windows XP.• In the Send Pattern function, an individual port cannot be stopped but all ports can be stopped simultaneously.EnhancementsWindows 2000, Windows 7, Windows Server 2003, Windows Server 2008, Windows Server 2008 R2,Windows Vista, Windows XPUSB-to-Serial Converters, Multiport Serial Boards, Serial Device Servers• Added byte transmit/receive counter in PComm Terminal.• PComm Terminal supports pasting clipboard content to terminal.New FeaturesN/A• Terminal Emulator: Supports all serial products, including non-Moxa products.• Diagnostic Utility: Supports Moxa Multiport Serial Boards.• Monitor Utility: Supports Moxa Multiport Serial Boards.• Performance Analyzer: Supports Moxa Multiport Serial Boards, UPort Series, and NPort Series.• PComm Library: Supports all serial products, including non-Moxa products.Supported Operating SystemsNotesChangesApplicable ProductsBugs Fixed• ncludes VC project example code for PComm library • Read method using RX_CHAR event.• Supports opening multiple COM ports.• Log files can be stored in a specified path/link.N/AEnhancementsWindows 2000, Windows 7, Windows Server 2003, Windows Server 2008, Windows Server 2008 R2,Windows Vista, Windows XPUSB-to-Serial Converters, Multiport Serial Boards, Serial Device Servers• Supports Windows 2008/2008 R2 (x86/x64).• Supports HEX code display for dumb mode.• Supports linear baud rate configuration.• Supports send pattern for multiple COM ports.• Supports data file pattern.• Supports interval time between sending two patterns.• Supports network communication: TCP Server/Client, UDP.• Supports auto line wrap.• Supports customizing terminal size.• Supports DTR/DSR flow control configuration.• Supports Performance Analyzer.New FeaturesN/A• Terminal Emulator: Supports all serial products, including non-Moxa products.• Diagnostic Utility: Supports Moxa Multiport Serial Boards.• Monitor Utility: Supports Moxa Multiport Serial Boards.• Performance Analyzer: Supports Moxa Multiport Serial Boards, UPort Series, and NPort Series.• PComm Library: Supports all serial products, including non-Moxa products.Supported Operating SystemsNotesChangesApplicable ProductsBugs Fixed• VT100 added "DEL" key support.• Modified all online help to HTML format.• PComm Lite supports up to COM1024.• Updated PComm.dll to fix ASCII tx causing VB program to hang if tx is held by CTS flow control.EnhancementsWindows 2000, Windows 7, Windows Server 2003, Windows Vista, Windows XPUSB-to-Serial Converters, Multiport Serial Boards, Serial Device Servers• Supports Windows Vista/7.New FeaturesN/A• Terminal Emulator: Supports all serial products, including non-Moxa products.• Diagnostic Utility: Supports Moxa Multiport Serial Boards.• Monitor Utility: Supports Moxa Multiport Serial Boards.• Performance Analyzer: Supports Moxa Multiport Serial Boards, UPort Series, and NPort Series.• PComm Library: Supports all serial products, including non-Moxa products.Supported Operating SystemsNotesChangesApplicable ProductsBugs Fixed• PComm Terminal display performance.• PComm Terminal status bar display problem.• PComm Terminal display problem with Moxa UC Series/EtherDevice/W2004 console.EnhancementsWindows 2000, Windows Server 2003, Windows XPUSB-to-Serial Converters, Multiport Serial Boards, Serial Device Servers• Utilities support Moxa MSB x64 driver.• PComm Library supports Windows x64 Edition (AMD64, EM64T). For cross development, x86 & x64library will both be installed.New FeaturesN/A• Terminal Emulator: Supports all serial products, including non-Moxa products.• Diagnostic Utility: Supports Moxa Multiport Serial Boards.• Monitor Utility: Supports Moxa Multiport Serial Boards.• Performance Analyzer: Supports Moxa Multiport Serial Boards, UPort Series, and NPort Series.• PComm Library: Supports all serial products, including non-Moxa products.。

nextpad release note

nextpad release note

各位,大家下午好。

欢迎各位百忙之中来现场参加这次在线的产品发布会活动,虽然这里说的是一个“产品”的发布会,但是按照产品的定义而言,下面要公布的也不能算是一个产品,因为它是没有价格的,也就是终生免费的一个产品(360?……)。

首先为了防止有人还不知道我是谁,我先自我介绍一下,我的GSDzone ID , sataco ,目前担任 GSDzone 网站的主要负责人以及泛华测控院校产品部的负责人。

因此,从今年开始,我会在试图在中国工程教育这个领域做一些事情,希望能够真正实质性地助力培养更多未来的卓越工程师。

在本次产品发布会期间,你都可以回帖进行提问或者单纯的顶或踩,在发布会结束时会进行最后的抽奖活动,大奖将是一个以前从来没有发过的奖品,而且不是 GSDzone 的奖品,而是 next 的奖品,尽请期待。

下面,我将用类似意识流的方式给大家阐述一下这个产品 nextpad 的概念是如何形成的。

为了真正助力中国工程教育,我思考了很久,之后想到了有三个方向也许是我以后会奋斗的目标:一个就是在教学方面,目前在工程知识的教学上尚存在着很大的提升空间,很多概念和知识,现在还是通过老一套的纯公式推导或者板书的形式来进行教授,这种方式不利于学生能够真正理解透彻知识点,而且不生动,引不起学生的兴趣和求学欲望;第二个方向就是实验,图腾中那条白色的线指的是理论中所得到的结果,而黄色的线代表的是在实际情况中所得到的结果,你可以明显看出两条线是不一样的,这也代表着也许你理论学得很好,但是作为一个优秀的工程师,你必不可少地要和实际的系统或环境打交道,所以掌握你的理论知识的同时,你更需要的是通过实验来将理论与实践联系在一起,真正做到工程。

第三个方向就是创新,这个图腾也很好理解,每一个框代表的是一门学科,那么在这个方向,是要求同学们能够灵活地将各个学科的知识综合起来解决实际问题,例如你在大一大二可能学习了电工电子、机械原理等基础课程,那么在大三大四甚至研究生时就应该能够将这些基础学科综合起来,从而解决真正的问题。

Rockwell Automation OptiSIS50 v1.1 Release Note说明书

Rockwell Automation OptiSIS50 v1.1 Release Note说明书

AADvanceThe Next Step in AutomationOptiSIS50 Release Note v1.1Issue 01 1711-RN002A-EN-PNovember 2017Release Note v1.1 This page is intentionally left blankContentsOptiSIS50 v1.1 is an incremental release of OptiSIS50 v1.0. This Release Note includes the following information:•Hardware and Software Builds for this Release •Enhancements to the System•Problems and Anomalies Resolved in this Release •Restrictions that still Apply•Tech Notes, Product Notices and Product Safety Advisories •Product Compatibility Rules•Technology Support and Additional ResourcesIssue RecordIssue Date Comments01 November 2017 Initial IssueCatalog No. Description DrawingIdentity SoftwareIdentitySoftwareRelease1711-P05SISID050S (1711-P05SISSAFU050S) OptiSIS 50 I/O solution,Indoor enclosure, Fail Safe option10003425624 v00 AADvanceFTView HMIv137B.151711-P05SISID050T (1711-P05SISSAFU050T) OptiSIS 50 I/O solution,Indoor enclosure, Fault Tolerant option10003425646 v001711-P05SISOD050S (1711-P05SISHAZU050S) OptiSIS 50 I/O solution,Outdoor enclosure, Fail Safe option10003425647 v001711-P05SISOD050T (1711-P05SISHAZU050T) OptiSIS 50 I/O solution,Outdoor enclosure, Fault Tolerant option10003425648 v00Hardware and Software Builds for this ReleaseThe following enhancements are included in this release.• Addition of FactoryTalk View Alarm Status ExplorerThe addition of the FactoryTalk View Alarm Status Explorer object provides an improved user experience, offering the ability to Shelve, Suppress and/or Disable alarms in the OptiSIS. The application logic is unaffected by the above, so the user may now disable valve limit switch alarms (for example) while still allowing the logic to perform as desired.• Offline Cause and Effect Configuration made retentiveThe OptiSIS offline Cause and Effect chart configuration has now been made retentive. Previously, after the OptiSIS experienced a power cycle a user would need to perform a Cause and Effect Configuration Upload before commencing any changes. Now, the OptiSIS Cause and Effect charts’ configuration will be retained through a power cycle, saving the user time when commencing any configuration changes in the field.Enhancements to the systemThe following problems and anomalies have been resolved in this release.• LAN A and LAN B faults did not generate alarms OptiSIS 50 I/O solutions up to and including v1.0 that utilizeModbusTCP communications between the AADvance controller and the Industrial PC had an error that caused LAN A and LAN B fault status to fail to alarm. This has been fixed in OptiSIS 50 HMI application version B.15, provided with the release.• Maintenance Page 4 may cause HMI problemsOptiSIS 50 I/O solutions up to and including v1.0 had a timing issue on Maintenance Page 4 that could, under certaincircumstances, cause the HMI to slow down or graphics to close unexpectedly. This has been fixed in OptiSIS 50 HMI application version B.15, provided with the release.Problems and Anomalies Resolvedin this ReleaseRestrictionsThe following restrictions apply to this release.•AADvance Product RestrictionsFor AADvance R1.34 Product Restrictions, refer to AADvanceR1.34 Release Note (ICSTT-RN005A).•FactoryTalk View SE Product RestrictionsFor FactoryTalk View SE Restrictions, refer to FactoryTalk ViewSite Edition User’s Guide (VIEWSE-UM006L).•6181-series Industrial PC Product RestrictionsFor 6181P-12A2SW71DC / 6181X-12TPW7DC ProductRestrictions, refer to Integrated Display Industrial Computers UserManual (6181P-UM003B-EN-P) and Visualization SolutionsSelection Guide (VIEW-SG001S).For Tech Notes, Product Notices and Product Safety Advisories applying to this OptiSIS release, refer to the following. • AADvance ControllerFor AADvance R1.34, refer to AADvance R1.34 Release Note (ICSTT-RN005A). • FactoryTalk View SEFor FactoryTalk View SE, refer to FactoryTalk View Site Edition User’s Guide (VIEWSE-UM006L). • 6181-series Industrial PCFor 6181P-12A2SW71DC / 6181X-12TPW7DC Industrial PCs, refer to Integrated Display Industrial Computers User Manual (6181P-UM003B-EN-P) and Visualization Solutions Selection Guide (VIEW-SG001S).Tech Notes, Product Notices and Product Safety AdvisoriesCompatibility RulesThese rules apply to this release:•This release of software is compatible with OptiSIS 50 I/O v1.0solutions.•AADvance processor and I/O module hardware (includingfirmware) must align with the AADvance Release 1.34compatibility matrix, as per AADvance Release Note R1.34(ICSTT-RN005A).•FactoryTalk View SE license must be compatible with FactoryTalkView SE 7.0.•KEPWare licence must be compatible with KEPServerEXv6.2.460.0.Rockwell Automation Publication 1711-RN002A-EN-P11PUBLICATION NUMBERUser Documentation is available at the Rockwell Automation Literature Library by searching for “OptiSIS”.The Literature Library is:/global/literature-library/overview.pageDOWNLOADSIMPORTANT The OptiSIS Industrial PC images are not available for download.The OptiSIS Offline Configuration Tool may be downloaded from the Product Compatibility and Download Center.The Product Compatibility and Download Center is: /rockwellautomation/support/pcdc.page Select the Find Downloads option under DownloadIn the Product Search field enter “OptiSIS” and the OptiSIS Safety Instrumented System option is displayed.Double click on the OptiSIS Safety Instrumented System option and the latest version is shown.Select the latest version and click Downloads to select the components to download.IMPORTANT A login is required to access the link. If you do not have an account then you can create one using the "Sign Up" link at the top right of the web page.Technical Supportand AdditionalResources。

Release Notes

Release Notes

Oracle® TimesTen In-Memory DatabaseRelease NotesRelease 11.2.1E13080-19November 2010This document provides late-breaking information for TimesTen release 11.2.1.7.0, aswell as information that is not yet part of the formal documentation. The latest versionof this document is the readme.html file in your installation directory. Release notesmay also be updated from time to time in the documentation library at/technetwork/database/timesten/documentation/Information about TimesTen 11.2.1 releases before 11.2.1.6.0 can be found at/technetwork/database/timesten/documentation/1121-historic-183693.htmlTo install the Oracle TimesTen In-Memory Database, run setup from the installationmedia pack. For installation information, see Oracle TimesTen In-Memory DatabaseInstallation Guide. This guide can be accessed from install_dir/doc/ at the root ofthe installation media pack.This document contains the following sections:■Changes in this release■Platforms■Software requirements■Deliverables■Advance notice■Known problems and limitations■Contacting support■Documentation Accessibility1Changes in this releaseThis section lists changes between releases:■Changes for Release 11.2.1.7.0 from Release 11.2.1.6.6■Changes for Release 11.2.1.6.6 from Release 11.2.1.6.5■Changes for Release 11.2.1.6.5 from Release 11.2.1.6.4■Changes for Release 11.2.1.6.4 from Release 11.2.1.6.3■Changes for Release 11.2.1.6.3 from Release 11.2.1.6.1■Changes for Release 11.2.1.6.1 from Release 11.2.1.6.0■Changes for Release 11.2.1.6.0 from Release 11.2.1.5.21.1Changes for Release 11.2.1.7.0 from Release 11.2.1.6.6The behaviorchanges.txt file is no longer included in the installation directory. Behavior changes are included in this document.1.1.1Behavior changes in Release 11.2.1.7.0■Previous behavior: If SUBSTR() result is longer than the target column, the result is silently truncated and an insert or update succeeds with the truncated string.New behavior: If the result of SUBSTR() is longer than the target column in an insert or update statement, the operation fails with error 982: "Stringexceeds column width". For example, if column x is of type CHAR(4), SET x=SUBSTR('abcdefg',2) results in error 982. SUBSTRB() in a multibytecharacter set continues to silently truncate the string, and insert or updatecontinues to succeed with the truncated string.1.1.2New features and changes in Release 11.2.1.7.0See the "What's New" prefaces in the documentation to see the new featuresdocumented in a specific guide.■You can create an explicitly loaded global cache group in a cache grid. If the cache tables on the local grid member do not contain data that satisfies a query, then thecache instance is transferred from other grid members to the local grid member in a grid data transfer operation. If the grid does not contain the cache instance that satisfies the query, data is not loaded from the Oracle tables and the query returns no results. See Oracle In-Memory Database Cache User's Guide .■Oracle Data Provider for .NET 11.1.0.7.110 is available for Oracle TimesTen In-Memory Database. It enables fast data access for .NET applications using. This data provider supports TimesTen release 11.2.1.6.1 or later onMicrosoft Windows 32-bit and 64-bit platforms. It supports the .NET 2.0, 3.0 and3.5 frameworks with Microsoft Visual Studio 2005 or later, and .NET4.0 withVisual Studio 2010. The Oracle Data Provider for .NET is available for download on Oracle Technology Network:/technetwork/database/timesten/downloads For more information, see Oracle Data Provider for .NET Oracle TimesTen In-Memory Database Support User's Guide .■Tables with aging are not supported with track-based parallel replication. In this release, TimesTen prevents the user from including a table with aging from beingpart of a replication scheme when ReplicationApplyOrdering=1.■TimesTen is supported for SUSE 11 on Linux x86-64.■The default value for the -maxsupportlogsize daemon option has been changed from 1 to 10 MB. See Oracle TimesTen In-Memory Database Operations Guide .Note:Oracle Data Provider for .NET 11.1.0.7.110 supports OracleTimesTen In-Memory Database only. A future release of OracleDatabase Provider for .NET will support both Oracle Database andOracle TimesTen In-Memory Database.■Aging statistics have been added to the SYS.SYSTEMSTATS system table. See Oracle TimesTen In-Memory Database System Tables and Limits Reference.■Using TimesTen with IBM Java SDK 1.6 for 32-bit and 64-bit on Linux x86 is supported. To use this Java SDK, a fix from IBM is required, published as APAR IZ76406, which is included in Java 6 SR8 FP1.■The ScriptInstallDir attribute is not required to configure Oracle Clusterware with TimesTen. The attribute is deprecated in this release.1.1.3Bug fixes in Release 11.2.1.7.0■The ttMigrate utility returns exit codes. See Oracle TimesTen In-Memory Database Reference. (BugDB 8637795)■In previous releases, ttBulkCp failures returned an incorrect code. This problem has been fixed. (BugDB 9414206)■In previous releases, the -showdate daemon option was not enabled for the Server process. This problem has been fixed. (BugDB 9722055)■ A CREATE VIEW statement fails if the view definition contains a union, and one side of the union is a query that selects from a derived table that is a join. In this release, TimesTen returns an error message that describes the problem. (BugDB 9864076)■Create cache group checks if the user has the appropriate Oracle privilege. For example, it checks if the user has SELECT ON privileges on each table in the cache group. In the 11.2.1.7.0 release, the code checks for individual privileges, as well as those granted through a role. In earlier releases, it was not checking against role privileges. (BugDB 9873532)■When grid failed to allocate memory a message will be logged to the daemon log to indicate this fact. The message will have the following format: Member'memberName'failed to allocate temp space, errorcode='errNo' - 'errMessage'. (BugDB 9893472)■Public access to TimesTen objects in the Oracle database that are used for cache operations is no longer allowed. (BugDB 9957021)■In previous releases, the fractional second field of an Oracle TIMESTAMP value contained in a PL/SQL variable buffer was inadvertently modified when it was prepared for conversion into the TimesTen TT_TIMESTAMP format. This problem has been fixed. (BugDB 9903966)■SQL operations executed internally by PL/SQL may generate warnings, for example, because of low memory or replication failures. In previous releases these warnings could cause ORA-0600 errors to be emitted. In this release ORA-0600 errors do not result from these temporary warning conditions. (BugDB 9916812)■In a client/server configuration, errors in starting child server processes resulted in an "unexpected server exit" and no additional information. Now startup errors are reported. (BugDB 9934387)■Internal trace buffers are now flushed when the database is loaded into memory.Previously, trace data left over from a prior load of the database could interfere with new traces, causing errors that could result in database invalidation. (BugDB 9939628)■In previous releases, a call to the ttOptEstimateStats built-in procedure could result in an assertion when a concurrent transaction committed after deleting alarge number of rows. In this release, TimesTen returns an error if TimesTen cannot perform the estimate. The new error has the form: "Estimate statistics on owner.table failed due to too some concurrent operation; try again." (BugDB 9954300)■In previous releases, altering a cache group could cause a core dump when the TimesTen configuration tables on the Oracle database were empty. This problem has been fixed. (BugDB 9956288)■The message for error 6226 has been changed to replace the obsolete LogBuffSize connection attribute name with LogBufMB. (BugDB 9961676)■The stability of TimesTen PL/SQL after unexpected application failures is improved. (BugDB 10011855)■In previous releases, a master-master replication scheme with two-safe enabled could create a backlog of replication records that were never sent to a subscriber database. This problem has been fixed. (BugDB 10029655)■In previous releases, calls to the ttOptSetFlag built-in procedure incorrectly reset the values set by the ttOptUseIndex built-in procedure. This problem has been fixed. (BugDB 10034510)■Dynamic load operations use the SQL command cache more efficiently than in previous releases. (Bug DB 10036720)■Dynamic load operations no longer cause a round trip to the Oracle database when the parent row is already in the IMDB Cache. (BugDB 10036751)■The mit.file.reads statistic in the SYS.SYSTEMSTATS system table.keeps track of how often TimesTen reads from the file system during commitprocessing. In previous releases, this statistic was higher than log.file.reads, which keeps track of total file system reads. The mit.file.readsstatistic is now calculated correctly. (BugDB 10134912)■In previous releases, a replication agent or an XLA application could encounter an assertion failure blklen <= startIdMap->offset in thesbLogBufLRNextLocate function. This problem has been fixed. (BugDB10145152, 10194728 and 10196227)■ A problem has been fixed where an assertion could occur while executing SELECT statement through a procedure from a JDBC application. (BugDB 10167873)■In previous releases, the replication agent could crash and invalidate the database when the replication agent was reading close to the end of the in-memory logs.This problem could occur when the value of the connection attributeLogBufParallelism was greater than 1. In that case, one particular log record could cause a log strand reader to block and cause other strand-readers to read records in an incorrect order. This problem has been fixed. (BugDB 10174319 and 10176689)■In previous releases, a bad pointer caused an assertion in thesblogCtnWrapComplete function. This problem has been fixed. (BugDB10176825)■ A problem has been fixed where timing issues after a ttCWAdmin -init operation could generate false positives. (BugDB 10208113)■In previous releases, global dynamic AWT cache groups checked the Oracle tables for unique primary keys when inserts were performed on the TimesTen cachetables. This uniqueness check no longer occurs, which enables inserts to take placein TimesTen cache tables when the Oracle database is not available. (BugDB10211940)■In previous releases, when a direct-linked application was terminated abnormally, other active connections or subsequent connections could cause databaseinvalidation. This problem has been fixed. (BugDB 10008657 and 10214446)■An assertion could occur when parallel replication was enabled. The transmitter would crash when reading close to the end of the log, causing an incorrect check that failed when a connection changed its replication track number. This problem has been fixed. (BugDB 10218953)■ A problem has been fixed where parallel replication would hang while running ttrepadmin -dsn DSN-receiver list. (BugDB 10223328)1.2Changes for Release 11.2.1.6.6 from Release 11.2.1.6.5■ A problem has been fixed where, if a secondary group was chosen during the installation and the TimesTen daemon is started by the root user, the daemon would run under the primary group rather than the intended group. (BugDB9968811)■For AIX on POWER systems, a problem has been fixed in which a misplaced memory barrier could lead to an assertion failure insbLogStrandGetNextRecord. (BugDB 10008972)■ A problem has been fixed where information about the group that owned the database was incorrectly removed from the database when duplicating orrestoring the database. This caused subsequently created log files to have incorrect ownership, group, and/or permissions. (BugDB 10020189)■ A problem has been fixed where the delete of the dummy row generated for concurrency control might be incorrectly treated as a deferred delete of AWT cache group. This might cause an error to be returned when the member attempted to reload the instance after it had been transferred or unloaded. (BugDB 10023143)■ A problem has been fixed where a mutex used for cache grid concurrency control might be released by a process other than the process that acquired the mutex.This problem could cause an assertion failure. (BugDB 10049032)1.3Changes for Release 11.2.1.6.5 from Release 11.2.1.6.4■You can use the ttRepStateGet built-in procedure to return the grid state as well as the database role after failover in an active standby pair grid member. See Oracle TimesTen In-Memory Database Reference for details.■ A problem has been fixed where tracing could cause a database to become invalidated. (BugDB 9088582 and 9940513)■ A problem has been fixed where a FIRST N in a SELECT query with a SET MINUS operator and many joins would choose a bad plan, consume a largeamount of temporary space and not execute. (BugDB 9867351)■ A problem has been fixed where an assertion failure could occur when the allocated buffer to store the foreign key of a dynamic load was too small. (BugDB 9924227)■Concurrent operations on detail tables of a materialized view could sometimes cause the materialized view to get out of sync. (BugDB 9977046)■In previous releases, durable commits could continue after the recovery of a failed standby master node in an active standby pair with RETURN TWOSAFE DURABLE COMMITS specified. This problem is fixed. (BugDB 9296545)■ A warning message is now included in the ttmesg.log when an error occurs with the configuration of HugePages on Linux systems. (BugDB 9582712)■Array binds to PL/SQL are not supported in TimesTen. In previous releases, attempts to bind an array would not return an error message, in some cases. Now the error message ORA-1335 "feature not supported" is returned when the calling program tries to specify an array (of more than one element) to a PL/SQLprocedure call. (BugDB 9645256)■ A problem has been fixed where a multi-table query with a LIKE predicate that passed a string whose length exceeded the width of the target column did nothave optimal performance and would take longer to complete than expected.(BugDB 9647431)■ A problem has been fixed where the ttbackupstatus built-in procedure would return the name of a backup file, even after a the ttBackup operation had been terminated before completing the backup. (BugDB 9658978)■Previously, the selectivity of the LIKE predicate with patterns ending in the wildcard character (e.g. "starts_with_this%") was underestimated, causing the optimizer to pick suboptimal plans for queries with an AND condition. (BugDB 9741326)■ A problem has been fixed where a ttMigrate operation would fail when attempting to migrate a PL/SQL package that contained multibyte character set comments. (BugDB 9747278)■In previous releases, SQLFetch and SQLFreeStmt(hstmt, SQL_CLOSE) could, in some circumstances, return the underlying error code (846 or 994) rather than trigger a failover. In this release, a failover notification is returned. (BugDB 9795626)■In previous releases, when permanent space was exhausted, a cache grid assertion failure could occur. This problem has been fixed. (BugDB 9871235)■ A problem has been fixed where the status report that is displayed when a user calls ttRepAdmin -showstatus would incorrectly show fewer receivers than transmitters. This problem occurred when using parallel replication. (BugDB9837882)■ A problem has been fixed where applications that use PL/SQL procedures could consume a lot of memory. (BugDB 9846145)■ A problem has been fixed where receiver thread information would continue to appear in the status report that is displayed when a user calls ttRepAdmin-showstatus even after the receiver had been disconnected. This problemoccurred when using parallel replication. (BugDB 9850072)■In previous TimesTen 11.x releases, if the database was created group restricted, and there was a failure to change group ownership of a log file, it could cause the database to become invalidated. This has been fixed. TimesTen now retrieschanging group ownership and returns more details about the operating system error if a failure occurs. (BugDB #9891312)■In previous 11.2.1 releases, use of an unreplicated XLA bookmark on a standby database in an active standby pair scheme could stop replication between theactive and standby stores and also lead to high CPU usage. This problem has been fixed. (BugDB 9800186)1.6Changes for Release 11.2.1.6.1 from Release 11.2.1.6.0■In previous releases, on AIX systems, the user had to call setsockopt at the kernel level to get the benefits of the TCP_RFC1323 option. It is no longernecessary for the user to make this call. TimesTen makes the call by default.(BugDB 6800684)■ A problem has been fixed where a disconnect from a standby store in an active standby pair with cache grid could hang. (BugDB 9538780)■In previous releases, creating many joins in a large materialized view could hang.This problem has been fixed. (BugDB 9581951)■TimesTen now returns ODBC error S1000: Unable to load NLS initialization data from /bogus/nls/data if the TimesTen clientdriver cannot find or load NLS files. (BugDB 9595956)■In previous releases, a replication agent could fail with this assertion failure: eolCnt + eofCnt == logc->strandCnt. This bug has been fixed. (Bug9644085).■During an upgrade from previous 11.2.1 releases to 11.2.1.6.0, the replication agent could fail to start due to error TT2211: Referenced column P.TRACK_ID not found>. This problem is fixed. (BugDB 9733793)1.7Changes for Release 11.2.1.6.0 from Release 11.2.1.5.21.7.1Behavior changes in Release 11.2.1.6.0■New behavior: The results for addition and subtraction with DATE and TIMESTAMP types for INTERVAL MONTH are not closed. For example, adding 12 months to the DATE or TIMESTAMP of '2004-02-29' results in a date arithmetic error (TimesTen error message 2787) because February 29, 2005 does not exist.(2005 is not a leap year.) Adding INTERVAL '1' MONTH to DATE'2005-01-30' results in the same error because February never has 30 days.This behavior is documented in Oracle TimesTen In-Memory Database SQL Reference, but the code did not return an error previously.Previous behavior: If the date is the last day of the month or if the resulting month has fewer days than the day component of DATE, then the result is the last day of the resulting month. Otherwise, the result has the same day component as DATE.Use the ADD_MONTHS function to get the old behavior. For example,ADD_MONTHS(DATE '2004-02-29',12) gives the result as DATE'2005-02-28', the last day of the month. ADD_MONTHS(DATE'2005-01-30',1) results in DATE '2005-2-28', the last day of the month.■The SELECT privilege has been granted to PUBLIC on theSYS.SYSTEM_PRIVILEGE_MAP and SYS.TABLE_PRIVILEGE_MAP systemtables. Public synonyms have also been created for these two tables.■JDBC client/server driver does not validate the index parameter in PreparedStatement.set XXX() calls. Validation occurs duringPreparedStatement.execute() calls.1.7.2New features and changes in Release 11.2.1.6.0See the "What's New" prefaces in the documentation to see the new features documented in a specific guide.■You can perform a global query on cache tables and noncache tables across all nodes in a cache grid. You can also unload a cache group on all grid members by specifying a global unload operation. Use the GlobalProcessing optimizer flag.For a detailed description, see the Oracle In-Memory Database Cache User's Guide.■TTClasses now supports PL/SQL IN, OUT and IN OUT parameters and REF CURSORs.■User-defined parallel replication can be configured for applications that have predictable transactional dependencies and do not require the commit order on the source database to be the same as the commit order on the target database.User-defined parallel replication is available for replication schemes that are not active standby pairs. See Oracle TimesTen In-Memory Database TimesTen to TimesTen Replication Guide for more information. This feature includes:- New database attributes ReplicationParallelism andReplicationApplyOrdering and the connection attributeReplicationTrack.-New SQL SET REPLICATION_TRACK clause of the ALTER SESSION statement.-The new TT_REPLICATION_TRACK ODBC connection option for the SQLSetConnectOption ODBC function.-The new setReplicationTrack() method of the TimesTenConnection JDBC classThe ALTER E INDEX operation is not permitted when user-defined parallel replication is used and replication agent is running.■Oracle Clusterware can be configured with a cache grid by setting the GridPort attribute in the cluster.oracle.ini file. See Oracle TimesTen In-MemoryDatabase TimesTen to TimesTen Replication Guide.1.7.3Bug fixes in Release 11.2.1.6.0■In previous releases, if you did a client-only install into a root directory, TimesTen would fail to find TimesTen servers during a Client DSN setup. This problem has been fixed. (BugDB 9261243)■ A problem has been fixed where a flush cache group operation would hold row locks on child tables. This problem could block an update statement that touched the child table. (BugDB 9359437)■In previous releases, executing a query against multiple outer joins with the set operators UNION, MINUS or INTERSECT could result in abnormal termination.This problem has been fixed. (BugDB 9382127)■ A problem has been fixed where the cache agent would not start if the ORA_NLS, ORA_NLS10 and ORA_NLS33 variables were set in the environment of theTimesTen main daemon. (BugDB 9382534)■ A deadlock or lock timeout error that could be encountered during a parallel ttMigrate restore operation has been fixed. (BugDB 9388441)■In previous releases, an autorefresh polling query incorrectly used a full table scan.In this release, the query uses an index. (BugDB 9434677)■An assertion failure that resulted from an inconsistency in TimesTen internal lock structures has been fixed in this release. (BugDB 9436967)■In previous releases, an assertion could occur if the total number of rows for a single value needed more than 65K pages in a bitmap index and subsequent fast recoveries would hang. This has been fixed. (BugDB 9445235)■In previous TimesTen 11.2.1. releases, replication would fail during an ALTER REPLICATION operation when replicating from a TimesTen 11.2.1.x release to a pre-11.2.1 release. This has been fixed. (BugDB 9447493)■ A problem has been fixed for Windows systems where Shared Memory IPC client server connections would fail sometimes. (BugDB 9478491)■The SQL command ID is included as output to ttXactAdmin. This ID is helpful as input for the built-in procedure ttSQLCmdCacheInfo to associate the SQL statement with the ID. (BugDB 9496444)■ A problem has been fixed where a TimesTen daemon disconnect would fail with an error -8 in the StopManaging function if a process had exited ungracefully.(BugDB 9499437)■ A problem has been fixed where projected constants in a JOIN of tables and views could create duplicate result column names. (BugDB 9503696)■In previous releases, when timestamp based aging is used, rows with date values in the future could be aged out. This problem has been fixed.(BugDB 9541351)■ A problem has been fixed where PL/SQL procedures could be stored incorrectly in the database. Any attempt to use these procedures would result in a crash.(BugDB 9542428)■In previous releases, when the value of the LogBufParallelism attribute was greater than 1, it could cause the transmitter in the replication agent to crash. This problem has been fixed. (BugDB9588242)2PlatformsEnvironment32-bit64-bit Compiler notesMicrosoft Windows 2000, Windows XP, Windows Vista and Windows Server 2003 and 2008 for Intel IA-32 and EM64T and AMD64 CPUs.Yes Yes Compiled and tested withIntel 8.VS .NET 2003, VS 2005 andVS 2008 are also supported.To use the TimesTen debuglibrary, you must use VS.NET 2003.Asianux 2.0 and 3.0 for Intel IA-32 and EM64T and AMD64 CPUs.Yes Yes Compiled and tested withIntel 9.1.gcc 3.4.6 and 4.1.0 are alsosupported.TimesTen is supported on Oracle VM guest x86 and x86-64 operating systems on Oracle Linux 4 and 5 or Red Hat Enterprise Linux 4 and 5 systems.Solaris 9 and 10 for UltraSparc CPUs.Yes Yes Compiled with Sun Studio 11.Shipped with a TimesTen client library compiled with gcc 3.2.3.Solaris 10 for x86-64.No Yes Compiled with Sun Studio 10. Tested on AMD64 CPUs.SUSE Linux Enterprise Server 10 for Intel IA-32 and EM64T and AMD64 CPUs.Yes Yes Compiled and tested with Intel 9.1.gcc 3.4.6 and 4.1.0 are also supported.SUSE Linux Enterprise Server 10 for Itanium2 CPUs.No Yes Compiled and tested with Intel 9.1.gcc 3.4.5 and 4.1.0 are also supported.SUSE Linux Enterprise Server 11 for Linux x86-84No Yes gcc 4.3Red Hat Enterprise Linux 4 and 5 for Intel Itanium2 CPUs.No Yes Compiled and tested with Intel 9.1.gcc 3.4.5 and 4.1.0 are also supported.Red Hat Enterprise Linux 4 and 5 for Intel IA-32 and EM64T and AMD64 CPUs.Yes Yes Compiled and tested with Intel 9.1.gcc 3.4.6 and 4.1.0 are also supported.Oracle Linux 4 and 5 for Intel IA-32 and EM64T and AMD64 CPUs.Yes Yes Compiled and tested with Intel 9.1.gcc 3.4.6 and 4.1.0 are also supported.Monta Vista Linux Carrier Grade Edition Release 4.0 and 5.0 for Intel IA-32, EM64T and AMD64 CPUs.Yes Yes Compiled and tested with Intel 9.1.gcc 3.4.6 and 4.1.0 are also supported.HP-UX 11i v2 and 11iv3 for PA-RISC.Yes Yes Compiled and tested with the HP compiler.HP-UX 11i v2 and 11iv3 for Itanium2.Yes Yes Compiled and tested with the HP compiler.AIX 5L 5.3 and 6.1 for POWER CPUs.Yes Yes Compiled and tested with the AIX compiler.Mac OS X 10.6Yes No Compiled and tested with gcc 4.2.1.Environment32-bit 64-bit Compiler notes3Software requirementsFor software requirements, refer to Oracle TimesTen In-Memory Database Installation Guide.4DeliverablesYou should receive the following with your copy of the Oracle TimesTen In-Memory Database:■Release Notes. This document (which you are now reading) covers late-breaking information not included in the formal documentation.■Oracle TimesTen Media Pack. The media pack includes the Oracle TimesTen libraries and executables, demo programs, utilities and online documentation. The documentation included on the media pack consists of:-Oracle TimesTen In-Memory Database Release Notes (Part Number E13080).See the description above.-Oracle TimesTen In-Memory Database Installation Guide (Part Number E13063). See the description above.-Oracle In-Memory Database Cache Introduction (Part Number E14261). This guide describes the features of Oracle In-Memory Database Cache andprovides information to help developers plan an IMDB Cache application.-Oracle TimesTen In-Memory Database Operations Guide (Part Number E13065). This guide provides information about configuring TimesTen andusing the ttIsql utility to manage a database. It also provides a basic tutorial for TimesTen.-Oracle TimesTen In-Memory Database C Developer's Guide (Part Number E13066). This guide describes how to compile and link your C applicationwith Oracle TimesTen and how to set up and work with Oracle TimesTendatabases. It covers topics that include error handling, event management and performance tuning. It also provides a reference for C language-specific APIs.-Oracle TimesTen In-Memory Database Java Developer's Guide (Part Number E13068). This guide describes how to compile and link your Javaapplication with Oracle TimesTen and how to set up and work with OracleTimesTen databases. It covers topics that include error handling, eventmanagement and performance tuning. It also provides a reference for Javalanguage-specific APIs.-Oracle TimesTen In-Memory Database TTClasses Guide (Part Number E13074). This guide describes the Oracle TimesTen C++ Interface Classeslibrary. The library provides wrappers around the most common ODBCfunctionality.-Oracle TimesTen In-Memory Database PL/SQL Developer's Guide (Part Number E13076). This guide describes and explains how to use PL/SQL in the TimesTen database. It is intended for anyone developing PL/SQL-basedapplications for the Oracle TimesTen In-Memory Database.-Oracle TimesTen In-Memory Database PL/SQL Packages Reference (Part Number E14000). This guide provides a reference to all PL/SQL packagesavailable for use with the TimesTen database. It is intended for anyonedeveloping PL/SQL-based applications for the Oracle TimesTen In-MemoryDatabase.。

Git ReleaseNotes

Git ReleaseNotes

Git Release Notes (Git-1.7.4-preview20110204)Last update: 4 February 2011IntroductionThese release notes describe issues specific to the Git for Windows release.General release notes covering the history of the core git commands are included in the subdirectory doc/git/html of the installation directory. Look for files starting with RelNotes.See / for further details about Git including ports to other operating systems. Git for Windows is hosted at /.Known issues∙Some commands are not yet supported on Windows and excluded from the installation;namely: git archimport, git cvsexportcommit, git cvsimport, git cvsserver, git instaweb, git shell.∙The Logitec QuickCam software can cause spurious crashes. See "Why does make often crash creating a sh.exe.stackdump file when I try to compile my source code?" on theMinGW Wiki (/wiki/Environment_issues)∙The Quick Launch icon will only be installed for the user running setup (typically the Administrator). This is a technical restriction and will not change.∙curl uses $HOME/_netrc instead of $HOME/.netrc.∙If you want to specify a different location for --upload-pack, you have to start the absolute path with two slashes. Otherwise MSys will mangle the path.∙git and bash have serious problems with non-ASCII file names (Issue 80, 159).∙If configured to use plink, you will have to connect with putty first and accept the host key.∙As merge tools are executed using the MSys bash, options starting with "/" need to be handled specially: MSys would interpret that as a POSIX path, so you need to double the slash (Issue 226). Example: instead of "/base", say "//base". Also, extra care has to be paid to pass Windows programs Windows paths, as they have no clue about MSys style POSIX paths -- You can use something like $(cmd //c echo "$POSIXPATH").Changes since Git-1.7.3.2-preview20101025New Features∙Comes with Git 1.7.4 plus patches.∙Includes antiword to enable viewing diffs of .doc files∙Includes poppler to enable viewing diffs of .pdf files∙Removes cygwin paths from the bash shell PATHBugfixes∙Please refer to the release notes for official Git 1.7.4Changes since Git-1.7.3.1-preview20101002New Features∙Comes with Git 1.7.3.2 plus patches.Changes since Git-1.7.2.3-preview20100911New Features∙Comes with Git 1.7.3.1 plus patches.∙Updated to Vim 7.3, file-5.04 and InnoSetup 5.3.11Bugfixes∙Issue 528 (remove uninstaller from Start Menu) was fixed∙Issue 527 (failing to find the certificate authority bundle) was fixed∙Issue 524 (remove broken and unused sdl-config file) was fixed∙Issue 523 (crash pushing to WebDAV remote) was fixedChanges since Git-1.7.1-preview20100612New Features∙Comes with Git 1.7.2.3 plus patches.Bugfixes∙Issue 519 (build problem with compat/regex/regexec.c) was fixed∙Issue 430 (size of panes not preserved in git-gui) was fixed∙Issue 411 (git init failing to work with CIFS paths) was fixed∙Issue 501 (failing to clone repo from root dir using relative path) was fixedChanges since Git-1.7.0.2-preview20100309New Features∙Comes with Git 1.7.1 plus patches.Bugfixes∙Issue 27 (git-send-mail not working properly) was fixed again∙Issue 433 (error while running git svn fetch) was fixed∙Issue 427 (Gitk reports error: "couldn't compile regular expression pattern: invalid repetition count(s)") was fixed∙Issue 192 (output truncated) was fixed again∙Issue 365 (Out of memory? mmap failed) was fixed∙Issue 387 (gitk reports "error: couldn't execute "git:" file name too long") was fixed∙Issue 409 (checkout of large files to network drive fails on XP) was fixed∙Issue 428 (The return value of git.cmd is not the same as git.exe) was fixed∙Issue 444 (Git Bash Here returns a "File not found error" in Windows 7 Professional - 64 bits) was fixed∙Issue 445 (git help does nothing) was fixed∙Issue 450 ("git --bare init" shouldn't set the directory to hidden.) was fixed∙Issue 456 (git script fails with error code 1) was fixed∙Issue 469 (error launch wordpad in last netinstall) was fixed∙Issue 474 (git update-index --index-info silently does nothing) was fixed∙Issue 482 (Add documentation to avoid "fatal: $HOME not set" error) was fixed∙Issue 489 (git.cmd issues warning if %COMSPEC% has spaces in it) was fixed∙Issue 436 ("mkdir : No such file or directory" error while using git-svn to fetch or rebase) was fixed∙Issue 440 (Uninstall does not remove cheetah.) was fixed∙Issue 441 (Git-1.7.0.2-preview20100309.exe installer fails with unwritable msys-1.0.dll when ssh-agent is running) was fixedChanges since Git-1.6.5.1-preview20091022New Features∙Comes with official Git 1.7.0.2.∙Comes with Git-Cheetah (on 32-bit Windows only, for now).∙Comes with connect.exe, a SOCKS proxy.∙Tons of improvements in the installer, thanks to Sebastian Schuberth.∙On Vista, if possible, symlinks are used for the built-ins.∙Features Hany's dos2unix tool, thanks to Sebastian Schuberth.∙Updated Tcl/Tk to version 8.5.8 (thanks Pat Thoyts!).∙By default, only .git/ is hidden, to work around a bug in Eclipse (thanks to Erik Faye-Lund). Bugfixes∙Fixed threaded grep (thanks to Heiko Voigt).∙git gui was fixed for all kinds of worktree-related failures (thanks Pat Thoyts).∙git gui now fully supports themed widgets (thanks Pat Thoyts and Heiko Voigt).∙Git no longer complains about an unset RUNTIME_PREFIX (thanks Johannes Sixt).∙git gui can Explore Working Copy on Windows again (thanks Markus Heidelberg).∙git gui can create shortcuts again (fixes issue 425, thanks Heiko Voigt).∙When "git checkout" cannot overwrite files because they are in use, it will offer to try again, giving the user a chance to release the file (thanks Heiko Voigt).∙Ctrl+W will close gitk (thanks Jens Lehmann).∙git gui no longer binds Ctrl+C, which caused problems when trying to use said shortcut for the clipboard operation "Copy" (fixes issue 423, thanks Pat Thoyts).∙gitk does not give up when the command line length limit is reached (issue 387).∙The exit code is fixed when Git.cmd is called from cmd.exe (thanks Alexey Borzenkov).∙When launched via the (non-Cheetah) shell extension, the window icon is now correct (thanks Sebastian Schuberth).∙Uses a TrueType font for the console, to be able to render UTF-8 correctly.∙Clarified the installer's line ending options (issue 370).∙Substantially speeded up startup time from cmd unless NO_FSTAB_THREAD is set (thanks Johannes Sixt).∙Update msys-1.0.dll yet again, to handle quoted parameters better (thanks Heiko Voigt).∙Updated cURL to a version that supports SSPI.∙Updated tar to handle the pax headers generated by git archive.∙Updated sed to a version that can handle the filter-branch examples.∙.git* files can be associated with the default text editor (issue 397).Changes since Git-1.6.4-preview20090729New Features∙Comes with official git 1.6.5.1.∙Thanks to Johan 't Hart, files and directories starting with a single dot (such as '.git') will now be marked hidden (you can disable this setting with core.hideDotFiles=false in your config) (Issue 288).∙Thanks to Thorvald Natvig, Git on Windows can simulate symbolic links by using reparse points when available. For technical reasons, this only works for symbolic links pointing to files, not directories.∙ A lot of work has been put into making it possible to compile Git's source code (the part written in C, of course, not the scripts) with Microsoft Visual Studio. This work is ongoing. ∙Thanks to Sebastian Schuberth, we only offer the (Tortoise)Plink option in the installer if the presence of Plink was detected and at least one Putty session was found..∙Thanks to Sebastian Schuberth, the installer has a nicer icon now.∙Some more work by Sebastian Schuberth was done on better integration of Plink (Issues 305 & 319).Bugfixes∙Thanks to Sebastian Schuberth, git svn picks up the SSH setting specified with the installer (Issue 305).Changes since Git-1.6.3.2-preview20090608New Features∙Comes with official git 1.6.4.∙Supports https:// URLs, thanks to Erik Faye-Lund.∙Supports send-email, thanks to Erik Faye-Lund (Issue 27).∙Updated Tcl/Tk to version 8.5.7, thanks to Pat Thoyts.Bugfixes∙The home directory is now discovered properly (Issues 108 & 259).∙IPv6 is supported now, thanks to Martin Martin Storsjö (Issue 182).Changes since Git-1.6.3-preview20090507New Features∙Comes with official git 1.6.3.2.∙Uses TortoisePlink instead of Plink if available.Bugfixes∙Plink errors out rather than hanging when the user needs to accept a host key first (Issue96).∙The user home directory is inferred from $HOMEDRIVE\$HOMEPATH instead of $HOME (Issue 108).∙The environment setting $CYGWIN=tty is ignored (Issues 138, 248 and 251).∙The "ls" command shows non-ASCII filenames correctly now (Issue 188).∙Adds more syntax files for vi (Issue 250).∙$HOME/.bashrc is included last from /etc/profile, allowing .bashrc to override all settings in /etc/profile (Issue 255).∙Completion is case-insensitive again (Issue 256).∙The "start" command can handle arguments with spaces now (Issue 258).∙For some Git commands (such as "git commit"), vi no longer "restores" the cursor position. Changes since Git-1.6.2.2-preview20090408New Features∙Comes with official git 1.6.3.∙Thanks to Marius Storm-Olsen, Git has a substantially faster readdir() implementation now. ∙Marius Storm-Olsen also contributed a patch to include nedmalloc, again speeding up Git noticably.∙Compiled with GCC 4.4.0Bugfixes∙Portable Git contains a README.portable.∙Portable Git now actually includes the builtins.∙Portable Git includes git-cmd.bat and git-bash.bat.∙Portable Git is now shipped as a .7z; it still is a self-extracting archive if you rename it to .exe.∙Git includes the Perl Encode module now.∙Git now includes the filter-branch tool.∙There is a workaround for a Windows 7 regression triggering a crash in the progress reporting (e.g. during a clone). This fixes issues 236 and 247.∙gitk tries not to crash when it is closed while reading references (Issue 125, thanks Pat Thoyts).∙In some setups, hard-linking is not as reliable as it should be, so we have a workaround which avoids hard links in some situations (Issues 222 and 229).∙git-svn sets core.autocrlf to false now, hopefully shutting up most of the git-svn reports. Changes since Git-1.6.2.1-preview20090322New Features∙Comes with official git 1.6.2.2.∙Upgraded Tcl/Tk to 8.5.5.∙TortoiseMerge is supported by mergetool now.∙Uses pthreads (faster garbage collection on multi-core machines).∙The test suite passes!Bugfixes∙Renaming was made more robust (due to Explorer or some virus scanners, files could not be renamed at the first try, so we have to try multiple times).∙Johannes Sixt made lots of changes to the test-suite to identify properly which tests should pass, and which ones cannot pass due to limitations of the platform.∙Support PAGERs with spaces in their filename.∙Quite a few changes were undone which we needed in the olden days of msysGit.∙Fall back to / when HOME cannot be set to the real home directory due to locale issues (works around Issue 108 for the moment).Changes since Git-1.6.2-preview20090308New Features∙Comes with official git 1.6.2.1.∙ A portable application is shipped in addition to the installer (Issue 195).∙Comes with a Windows-specific mmap() implementation (Issue 198).Bugfixes∙ANSI control characters are no longer shown verbatim (Issue 124).∙Temporary files are created respecting core.autocrlf (Issue 177).∙The Git Bash prompt is colorful again (Issue 199).∙Fixed crash when hardlinking during a clone failed (Issue 204).∙An infinite loop was fixed in git-gui (Issue 205).∙The ssh protocol is always used with plink.exe (Issue 209).∙More vim files are shipped now, so that syntax highlighting works.Changes since Git-1.6.1-preview20081225New Features∙Comes with official git 1.6.2.∙Comes with upgraded vim 7.2.∙Compiled with GCC 4.3.3.∙The user can choose the preferred CR/LF behavior in the installer now.∙Peter Kodl contributed support for hardlinks on Windows.∙The bash prompt shows information about the current repository.Bugfixes∙If supported by the file system, pack files can grow larger than 2gb.∙Comes with updated msys-1.0.dll (should fix some Vista issues).∙Assorted fixes to support the new libexec/git-core/ layout better.∙Read-only files can be properly replaced now.∙git-svn is included again (original caveats still apply).∙Obsolete programs from previous installations are cleaned up.Changes since Git-1.6.0.2-preview20080923New Features∙Comes with official git 1.6.1.∙Avoid useless console windows.∙Installer remembers how to handle PATH.Changes since Git-1.6.0.2-preview20080921Bugfixes∙ssh works again.∙'git add -p' works again.∙Various programs that aborted with 'Assertion failed: argv0_path' are fixed. Changes since Git-1.5.6.1-preview20080701Removed Features∙git svn is excluded from the end-user installer (see Known Issues).New Features∙Comes with official git 1.6.0.2.Bugfixes∙No Windows-specific bugfixes.Changes since Git-1.5.6-preview20080622New Features∙Comes with official git 1.5.6.1.Bugfixes∙Includes fixed msys-1.0.dll that supports Vista and Windows Server 2008 (Issue 122). ∙cmd wrappers do no longer switch off echo.Changes since Git-1.5.5-preview20080413New Features∙Comes with official git 1.5.6.∙Installer supports configuring a user provided plink (PuTTY).Bugfixes∙Comes with tweaked msys-1.0.dll to solve some command line mangling issues.∙cmd wrapper does no longer close the command window.∙Programs in the system PATH, for example editors, can be launched from Git without specifying their full path.∙"git stash apply stash@{1}" works.∙Comes with basic ANSI control code emulation for the Windows console to avoid wrapping of pull/merge's diffstats.∙Git correctly passes port numbers to PuTTY's plinkChanges since Git-1.5.4-preview20080202New Features∙Comes with official git 1.5.5.∙core.autocrlf is enabled (true) by default. This means git converts to Windows line endings (CRLF) during checkout and converts to Unix line endings (LF) during commit. This is the right choice for cross-platform projects. If the conversion is not reversible, git warns the user.The installer warns about the new default before the installation starts.∙The user does no longer have to "accept" the GPL but only needs to press "continue".∙Installer deletes shell scripts that have been replaced by builtins. Upgrading should be safer. ∙Supports "git svn". Note that the performance might be below your expectation.Bugfixes∙Newer ssh fixes connection failures (issue 74).∙Comes with MSys-1.0.11-20071204. This should solve some "fork: resource unavailable"issues.∙All DLLs are rebased to avoid problems with "fork" on Vista.Changes since Git-1.5.3.6-preview20071126New Features∙Comes with official git 1.5.4.∙Some commands that are not yet suppoted on Windows are no longer included (see Known Issues above).∙Release notes are displayed in separate window.∙Includes qsort replacement to improve performance on Windows 2000.Bugfixes∙Fixes invalid error message that setup.ini cannot be deleted on uninstall.∙Setup tries harder to finish the installation and reports more detailed errors.∙Vim's syntax highlighting is suitable for dark background.Changes since Git-1.5.3.5-preview20071114New Features∙Git is included in version 1.5.3.6.∙Setup displays release notes.Bugfixes∙pull/fetch/push in git-gui works. Note, there is no way for ssh to ask for a passphrase or for confirmation if you connect to an unknown host. So, you must have ssh set up to workwithout passphrase. Either you have a key without passphrase, or you started ssh-agent.You may also consider using PuTTY by pointing GIT_SSH to plink.exe and handle your ssh。

ACS6000 LXEB Release Note

ACS6000 LXEB Release Note

ABB Switzerland Ltd.ACS 6000MainINT FirmwareRelease NotesAuthor:18.12.13 / M. Studer approved:18.12.13 / O. ScheussDepartement:ATDD Based on:-Language Rev.PagesNOTICEThe information in this document is subject to change without notice and should not be construed, as a commitment by ABB Switzerland Ltd. ABB Switzerland Ltd assumes no responsibility for any errors that may appear in this document. In no event shall ABB Switzerland Ltd be liable for direct, indirect, special, incidental, or consequential damages of any nature or kind arising from the use of this document, nor shall ABB Switzerland Ltd be liable for incidental or consequential damages arising from use of any software or hardware described in this document.This document and parts thereof must not be reproduced or copied without ABB Switzerland Ltd’s written permission, and the contents thereof must not be imparted to a third party nor be used for any unauthorized purpose.NOTICE (2)CHAPTER 1INTRODUCTION (5)1.1Purpose of this document (5)CHAPTER 2SUMMARIZED RELEASE INFORMATION (6)2.1Changes from Release LXEB4300 Build 6 to LXEB4310 Build 0 (6)2.1.1Changed Features (6)2.1.2New Features (6)2.1.3Bug Fixes (6)2.2Changes from Release Version LXEB4210 Build 0 to LXEB4300Build 6 (6)2.2.1Changed Features (6)2.2.2New Features (6)2.2.3Bug Fixes (6)2.3Changes from Release Version LXEB4200 Build 0 to LXEB4210Build 0 (7)2.3.1Changed Features (7)2.3.2New Features (7)2.3.3Bug Fixes (7)2.4Changes from Release Version LXEB4100 Build 0 to LXEB4200Build 0 (7)2.4.1Changed Features (7)2.4.2New Features (7)2.4.3Bug Fixes (7)2.5Changes from Release Version LXEB4000 Build 1 to LXEB4100Build 0 (8)2.5.1Changed Features (8)2.5.2New Features (8)2.5.3Bug Fixes (8)2.6Changes from Release Version LXEB3xxx to LXEB4000 Build 1 (8)CHAPTER 3DETAILED RELEASE INFORMATION (9)3.1Changes from Release LXEB4300 Build 6 to LXEB4310 Build 0 (9)3.1.1Changed Features (9)3.1.2New Features (9)3.1.3Bug Fixes (9)3.2Changes from Release Version LXEB4210 Build 0 to LXEB4300Build 4 (9)3.2.1Changed Features (9)3.2.2New Features (9)3.2.3Bug Fixes (10)3.3Changes from Version LXEB4200 Build 0 to LXEB4210 Build 0 (10)3.3.1Changed Features (10)3.3.2New Features (10)3.3.3Bug Fixes (10)3.4Changes from Version LXEB4100 Build 0 to LXEB4200 Build 0 (11)3.4.1Changed Features (11)3.4.2New Features (11)3.4.3Bug Fixes (11)3.5Changes from Version LXEB4000 Build 1 to LXEB4100 Build 0 (11)3.5.1Changed Features (11)3.5.2New Features (11)3.5.3Bug Fixes (11)3.6Changes from Version LXEB3xxx to LXEB4000 Build 1 (12)CHAPTER 4COMPATIBILITY (13)4.1Version LXEB4300 Build 6 (13)CHAPTER 5REFERENCES (14)CHAPTER 6GENERAL COMMISSIONINGINFORMATION (15)6.1How to Program the Firmware (15)6.1.1Requirements (15)6.1.2Downloading (15)CHAPTER 7BUILD INFORMATION (16)7.1Implementation/Synthesis Tool Versions (16)7.2Xilinx ISE 12.4 Build Design Summary (16)7.3Flash File Checksums (18)Chapter 1 Introduction1.1 Purpose of this documentThis document describes the changes included in the new ACS 6000 MainINT(previously PUBPFF) firmware.Chapter 2 Summarized Release Information2.1 Changes from Release LXEB4300 Build 6 to LXEB4310Build 02.1.1Changed FeaturesChanged FeaturesSSI encoder interface extension to 16 bits2.1.2New FeaturesNew Featuresnone2.1.3Bug FixesBug Fixesnone2.2 Changes from Release Version LXEB4210 Build 0 toLXEB4300 Build 62.2.1Changed FeaturesChanged FeaturesSwitch position comparison for quadruple configurations2.2.2New FeaturesNew FeaturesPUB_parallel mode2.2.3Bug FixesBug FixesLink Fault in Case of Load Balancing2.3 Changes from Release Version LXEB4200 Build 0 toLXEB4210 Build 02.3.1Changed FeaturesChanged FeaturesNone2.3.2New FeaturesNew FeaturesNone2.3.3Bug FixesBug FixesPPCC_RXFailed Timing Constraints2.4 Changes from Release Version LXEB4100 Build 0 toLXEB4200 Build 02.4.1Changed FeaturesChanged FeaturesNone2.4.2New FeaturesNew FeaturesPPCC Link AD Data of all INT boards available to AMC2.4.3Bug FixesBug FixesNone2.5 Changes from Release Version LXEB4000 Build 1 toLXEB4100 Build 02.5.1Changed FeaturesChanged FeaturesNone2.5.2New FeaturesNew FeaturesArc Detection via EOI Board2.5.3Bug FixesBug FixesNone2.6 Changes from Release Version LXEB3xxx to LXEB4000Build 1New MainINT concept (including new PFF link)Chapter 3 Detailed Release Information3.1 Changes from Release LXEB4300 Build 6 to LXEB4310Build 03.1.1Changed FeaturesChanged FeaturesThe SSI-clock frequency used to be set to 187.5kHz which allowed a data transmission rate of 13bits per 100µs. In order to increase the transmission rate to 16bits per 100µs, the SSI-clock is now set to 220kHz.3.1.2New FeaturesNew Featuresnone3.1.3Bug FixesBug Fixesnone3.2 Changes from Release Version LXEB4210 Build 0 toLXEB4300 Build 43.2.1Changed FeaturesSwitch position comparison for quadruple configurationsIn case of a quadruple INU configuration (applicable for DBC configurations), the switch position comparison is no longer made over all four INUs. Now only the switch positions of INU0 and INU1 as well as the switch positions of INU2 and INU3 are compared. This is necessary for the Semi Master+ and Semi Slave+ with DCB_QUAD configurations, since all four INT boards (and their links) are enabled but only the slave respectively the master side is modulating.Work Item [#]None3.2.2New FeaturesPUB_parallel modeThe PUB_parallel module acts as a bridge between the AMC3 board and up to 4 INT boards using a mixture of parallel interface (copper cable, direction AMC) and PPCC (serial, direction ARU/INU INT board) communication links. Please refer to the respecting technical documentation [2] in order to adjust the system with the required copper cable / fiber optic connections.Communications between the AMC34 board and the PUB_parallel module are carried by a parallel (copper cable) interface. This allows very fast communication (up to ~400 Mbit/s) and therefore removes some of the communication challenges faced by the PUB_serial module. The PUB_parallel module is disabled by default and can be enabled by setting the PUB_PAR_EN bit.Work Item [#]114233.2.3Bug FixesLink Fault in Case of Load BalancingIn case of active load balancing (used for hard parallel operation) the PPCC reset command to INU-INT boards was not forwarded correctly and thus ignored.This resulted in a tripped state of the AMC which could never be reset.Work Item [#]176483.3 Changes from Version LXEB4200 Build 0 to LXEB4210Build 03.3.1Changed FeaturesNone3.3.2New FeaturesNone3.3.3Bug FixesPPCC_RXA bug in the PPCC communication handling has been fixed. Before a communication fault could have been indicated without real fault.Work Item [#]13216Failed Timing ConstraintsFixed failed timing constraints in SSI Encoder instance.Manually added clock buffer for generated SSI encoder instance clock.Work Item[#]150533.4 Changes from Version LXEB4100 Build 0 to LXEB4200Build 03.4.1Changed FeaturesNone3.4.2New FeaturesPPCC Link AD Data of all INT boards available to AMCAll AD data coming via the PPCC Links A/B from the INU-/ARU-INT boards 1-4 has been put into the parallel link interface. This make it possible that the AMC can access all information of all INU-/ARU-INT boards at any time.Work Item [#]3.4.3Bug FixesNone3.5 Changes from Version LXEB4000 Build 1 to LXEB4100Build 03.5.1Changed FeaturesNone3.5.2New FeaturesArc Detection via EOI BoardIt is now possible to connect an arc detection device via the EOI board (UF C912 A, for details please refer to 3BHS359873 E02) to the optical input A530 on the MainINT (previously PUBPFF). When an arc is detected, the MainINT initiates (provided that the corresponding parameter in the Ctrl. SW is activated) a firing through. The communication to the EOI board provides link fault detection to prevent unwanted firing throughs in case of link problems. Note: This feature is only supported in SD Ctrl. SW versions above LSOI600D and AD Ctrl. SW versions above LAOI600C.Work Item [#]74253.5.3Bug FixesNone3.6 Changes from Version LXEB3xxx to LXEB4000 Build 1New MainINT2concept·Includes new PFF concept·Requires parallel link (X1200) to be connected to AMC·Only compatible with (INU/ARU) INT2 Boards and Ctrl. SW versions starting from LSOI600x and LAOI600x.Note: See also [1] for more information on the new MainINT/PFF concept.Work Item [#]1134.1 Version LXEB4300 Build 6Target Version ment AMC34SD SW Version AD SW Version >=LSOI600x Note: Arc Detection functionality not yetsupported in LSOI600D>=LAOI600x Note: Arc Detection functionality not yetsupported in LAOI600CChapter 4 CompatibilityChapter 5 References[1]ACS 6000 INT2 new PFF Specification.docx [$/ACS 6000/Documents/ACS6000 Common/Concepts/ACS 6000 INT2 new PFF Specification.docx]P.Bohren, ATDD2, 2011-01-05[2]ACS 6000 INT2 MainINT Technical Description[$/ACS6000/Documents/ACS 6000 Common/Concepts/ACS6000 INT2 MainINTTechnical Description LXEB.docx]ATDD, rev. 272406.1 How to Program the Firmware6.1.1RequirementsA PC with ‘Xilinx ISE Design Suite' installed.Xilinx JTAG Programmer.Programming files: int2pubpff_0.mcs, int2pubpff_1.mcsScript files: LXEBxxxx.cmd and PROG_LXEB.batAlways switch off the gate units to guarantee that no IGCT canswitch during the programming of the EPCs.Never operate the drive with invalid FPGA configuration, e.g.-Failed verification after downloading-Downloading of not matching int2pubpff_0.mcs andint2pubpff_1.mcs6.1.2DownloadingRun the PROG_LXEB.bat batch file to flash the firmware to the board. Chapter 6 General Commissioning Information7.1 Implementation/Synthesis Tool VersionsTool VersionSynplify8.6.2Xilinx ISE12.47.2 Xilinx ISE 12.4 Build Design Summaryint2_gpp_int Project Status (10/17/2014 - 14:20:56) Project File:int2pubpff.xise Parser Errors:No ErrorsModule Name:int2_gpp_int Implementation State:Programming File GeneratedTarget Device:xc3s1600e-4fg320·Errors:No ErrorsProduct Version:ISE 12.4·Warnings:674 Warnings (0new, 322 filtered)Design Goal:TimingPerformance·RoutingResults:All SignalsCompletely RoutedDesign Strategy:SmartXplorer -mapuseioreg·TimingConstraints:All ConstraintsMetEnvironment:System Settings·Final TimingScore:0(Timing Report)Device Utilization Summary[-] Logic Utilization Used Available Utilization Note(s)Number of Slice Flip Flops10,34729,50435%Number of 4 input LUTs17,35729,50458%Number of occupied Slices11,69714,75279%Number of Slices containing onlyrelated logic11,69711,697100% Number of Slices containingunrelated logic011,6970% Total Number of 4 input LUTs17,49529,50459%Number used as logic16,247Chapter 7 Build InformationNumber used as a route-thru138Number used as 16x1 ROMs672Number used for Dual Port RAMs352Number used as Shift registers86Number of bonded IOBs15825063%IOB Flip Flops1Number of RAMB16s203655%Number of BUFGMUXs52420%Number of DCMs3837%Number of MULT18X18SIOs83622%Average Fanout of Non-Clock Nets 3.60Performance Summary[-]Final Timing Score:0 (Setup: 0, Hold: 0, ComponentSwitching Limit: 0)PinoutData:Pinout ReportRouting Results:All Signals Completely Routed ClockData:Clock ReportTimingConstraints:All Constraints MetDetailed Reports[-] Report Name Status Generated Errors Warnings Infos Synthesis ReportTranslation Report CurrentFr 17. Okt12:56:46 20141 Warning (0new, 0 filtered)8 Infos (2 new,0 filtered)Map Report Current Fr 17. Okt13:28:08 2014322 Warnings (0new, 0 filtered)11 Infos (0 new,0 filtered)Place and Route Report CurrentFr 17. Okt13:35:43 201429 Warnings (0new, 0 filtered)1 Info (0 new, 0filtered)Power ReportPost-PAR Static Timing Report CurrentFr 17. Okt13:36:28 2014005 Infos (0 new,0 filtered)Bitgen Report Current Fr 17. Okt14:20:50 2014322 Warnings (0new, 322filtered)3 Infos (0 new,0 filtered) Secondary Reports[-]Report Name Status Generated SmartXplorer Report Current Fr 17. Okt 13:37:30 2014WebTalk Report Current Fr 17. Okt 14:20:51 2014 WebTalk Log File Current Fr 17. Okt 14:20:56 2014Date Generated: 10/17/2014 - 14:20:567.3 Flash File ChecksumsFlash File Checksumint2pubpff_0.mcs0x01307085int2pubpff_1.mcs0x04DBEC24。

ReleaseNote_项目名称_版本号_日期_版本等级_SVN标签

ReleaseNote_项目名称_版本号_日期_版本等级_SVN标签

文档名称:项目名_版本号_日期_版本等级文档编号:
归档日期:
文档版本:
编写者:
审核者:
批准者:
Release Note
1.目的:
指导正式发布软件本,对发布的软件版本加以详细说明,比如增加哪些功能、解决了哪些问题、还遗留哪些问题、对软件的架构、代码做了哪些相应修改,并对软件测试提出某些测试要求和注意事项,指导软件测试人员对该版本进行针对性的测试。

2.适用范围:
哈尔滨项目组
3. 本版本简要说明
4. 本软件版本的升级说明
5. 本版本软件的重要修正或重大改进
6. 本版本所支持的新功能
7. 本版本中未支持的功能
8. 本版本已解决的问题清单
9. 本版本中已知的遗留问题
无锡爱维特信息技术有限责任公司 2。

发布说明(ReleaseNote)

发布说明(ReleaseNote)
3
[内容]
列出用户需求中所描述的系统运行环境,描述清楚哪些是全部测试过的环境,哪些是部分测试过的环境(例如只做过安装部署),哪些是没有测试过的环境。
[裁剪原则]
关于此项若没有特殊说明,此部分内容不允许裁剪掉。
4
[内容]
相对于前一个版本,增加了哪些新的功能。
[裁剪原则]
关于此项若没有特殊说明,此部分内容允许裁剪掉。
产品、文档的未解决的bug,不包含建议bug;
文档评审的未解决的问题;
[裁剪原则]
关于此项若没有特殊说明,此部分内容不允许裁剪掉。
8
附图目录
表格目录
某企业全称user full name
发布说明
企业全称
2020年8月22日
文档属性
属性
内容
客户名称
某企业全称user full name
项目名称
项目全称project full name
文档主题
发布说明
文档副标题
文档版本
0.1
文档日期
文档状态
草案
作者
文档变更
版本
修订日期
修订人
描述
文档送呈
姓名
目的
1
产品名称
中文
运行平台
英文
发布日期
发布版本
产品经理
开发经理
发布版本在FTP服务器的目录
产品依赖
本产品正常运行依赖的产品及版本号;
例如:UltraPASM 2.0.8以上,UIP 1.0.1以上等。
2
[内容]
对本产品的功能做简单介绍,并描述产品包括的模块,说明各模块的功能。
[裁剪原则]
关于此项若没有特殊说明,此部分内容不允许裁剪掉。

Original ReleaseNote(Dr_ABE_BendV34018P7)

Original ReleaseNote(Dr_ABE_BendV34018P7)

process data are not read.
Release Note (Dr.ABE_Bend)-Version: 3.30-60.18P7
Precautions and restrictions on use #02 * About [AMNC Ver.5.0] If your using NC is AMNC-Ver.5.0.0000.0058sp4 or later, please register a machine by selecting [AMNC Ver.5.0] in [NC Type] in [new create] in [Machine Registration] in [Parameter]. It is possible to output CAM data for AMNC Ver.5.0. *1: The production with this version at FUJINOMIYA factory is October or later in 2007. *2: The version upgrade CD for serviceman was already distributed on August 24 in 2007. Besides, the bend data, which was created by [AMNC Ver.5.0] format, cannot be read and operated by NT-bender (AMNCVer3.0/4.0 series).
Created on: Jun. 9, 2008
Release Note (Dr.ABE_Bend)-Version: 3.30-60.18P7
Introduction This document is the release not regarding Dr.ABE_Bend Version 3.30-60.18 P7. It describes precautions and restrictions on use, installation, addition and improvement of features, and support of technical report. Besides, please refer to the [Operation Guideline] and operation manual for detailed handling about Dr.ABE_Bend. * Regarding [Bend Model File 5.0] In [Bend Model File 5.0] that is created based on the unfolded drawing, which is created by AP100, it became possible to express forming shape and special bend such as Z-bend, but features haven't been supported yet by AMNC. We're developing new features using [Bend Model File 5.0]. * Regarding [AMNC Ver.5.0] It is possible to output CAM data for AMNC Ver.5.0. If your using NC is AMNC Ver.5.0, please select [AMNC Ver.5.0] at [NC type]-[new create] in [Machine Registration][Parameter], and register a machine. The NT-bender(AMNC-Ver.3.0,Ver.4.0) can not use the bending data made by Dr.ABE_Bend ([NC type]=[AMNC Ver.5.0]). And you have to used this Dr. ABE_Bend (Version 3.30-60.18 P7),if Dr.ABE_Bend-Manual uses the bending data made by the NT-bender (AMNC-Ver.5.0.000.0058.sp3b,Ver.5.0.000.0058.sp3).

MXview 3.0 Release Notes说明书

MXview 3.0 Release Notes说明书

MXview Trial Version Release NotesSupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/AN/AEnhancementsWindows 10, Windows 7, Windows Server 2012 R2, Windows Server 2016MXview-2000, MXview-250, MXview-50, MXview-500, MXview Upgrade-50, MXview-100, MXview-1000• Interface to monitor up to 10 MXview sites.• RESTful API of MXview.• URL/iframe to integrate MXview topology into other applications.• Dashboard that allows the network status to be viewed at a glance.• Add 60-day free trial when MXview 3.0 is first activated.• Add interface languages: Japanese, German, and French.• The status of the current event can be viewed in the device property tag.New Features• New User Interface based on HTML5.• Modified the license registration process.• IGMP Visualization and SMS notifications were removed.• The OID import manager, MXconfig, N-Snap, Demo mode needed to be activated separately.N/ASupported Operating SystemsNotesChangesApplicable ProductsBugs Fixed• The ICMP and SNMP polling interval value does not change after restarting MXview.• An unexpected large packet could potentially crash the MXview Server.• Remote users can read the randomly generated private key for MXview's self-signed certification.• PT-7528 hardware version 2.0 could not be viewed.• Set SNMPv3 auth type at add device, only SHA will be activated event choose MD5 or SHA.• Modify the scenario of the virtual demo.EnhancementsWindows 10, Windows 7, Windows 8, Windows Server 2012, Windows Server 2012 R2, Windows XP MXview-100, MXview-1000, MXview-2000, MXview-250, MXview-50, MXview-500, MXview Upgrade-50• Customized name for port label.• Inventory report can export to PDF or CSV file.• Support the PRP/HSR topology on PT-7728-PTP.• The old version database can be upgrade to the current version and restore.• Following models supported: MGate 5103, MGate 5111, AWK-1137C, TAP-213, PT-G7728/G7828,EDS-P506E.• Security view supported in the following model, EDR-G902/G903 (with firmware after v4.2), EDR-810 (with firmware after v4.2), MGate-5118, MGate 5101- PBM-MN, MGate 5103, MGate 5109, MGate W5108, MGate W5208.New Features• Icon, topology, background image and the document of device remains after MXview is upgraded.• Prevent non-privileged local users executing arbitrary code with elevated privileged on the system.• HTTPS certificates will not show under web folder.• RSA keys of SSL certificate increase from 1024 to 2048 bits.N/ASupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/A• Fixed the login issue of DB Restore Tool.• When MXview is reactivated, the SNMPv3 connection between MXview and the network device will occasionally be lost.• When the SNMPv3 configuration is active, the process might hang during the MXview discovery process.EnhancementsWindows 10, Windows 7, Windows 8, Windows Server 2008, Windows Server 2012, Windows Server 2012 R2, Windows XPMXview Upgrade-50, MXview-100, MXview-1000, MXview-2000, MXview-250, MXview-50, MXview-500• Security View: Security level of network devices in a glance.• Dynamic wireless dashboard for AWK-A Series.• Support Windows 10 & server 2012 R2 (32/64-bit).New FeaturesN/AN/ASupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/AN/AEnhancementsWindows 10, Windows 7, Windows 8, Windows Server 2008, Windows Server 2012, Windows XP MXview Upgrade-50, MXview-100, MXview-1000, MXview-2000, MXview-250, MXview-50, MXview-500• Built-in MXview client.• Multiple user-defined accounts.• Security notifications and visualization.New FeaturesN/AN/ASupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/AN/AEnhancementsWindows 10, Windows 7, Windows 8, Windows Server 2008, Windows Server 2012, Windows XP MXview Upgrade-50, MXview-100, MXview-1000, MXview-2000, MXview-250, MXview-50, MXview-500• Visualization for PT-G503 PRP/HSR Redundant Box.New FeaturesN/AN/ASupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/AN/AEnhancementsWindows 7, Windows 8, Windows Server 2008, Windows Server 2012, Windows XPMXview Upgrade-50, MXview-100, MXview-1000, MXview-2000, MXview-250, MXview-50, MXview-500• Supports virtual demo network.• Supports traffic load visualization.• Supports VPN tunnel visualization.• Supports Syslog server.New FeaturesN/AN/ASupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/AN/AEnhancementsWindows 7, Windows 8, Windows Server 2008, Windows Server 2012, Windows XPMXview Upgrade-50, MXview-100, MXview-1000, MXview-2000, MXview-250, MXview-50, MXview-500• Generate custom events and notifications.• Generate custom OPC tags.• Export, import, copy, and paste device list.• Built-in browser.• Supports Windows 8 and Windows Server 2012.New FeaturesN/AN/ASupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/AN/AEnhancementsWindows 7, Windows 8, Windows Server 2008, Windows Server 2012, Windows XPMXview Upgrade-50, MXview-100, MXview-1000, MXview-2000, MXview-250, MXview-50, MXview-500• Supports new SNMP agent function.• Supports new OPC tag of Health status of group.New FeaturesN/AN/ASupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/A• Fixed event playback time synchronizing bug while using daylight-saving time.EnhancementsWindows 7, Windows 8, Windows Server 2008, Windows Server 2012, Windows XPMXview Upgrade-50, MXview-100, MXview-1000, MXview-2000, MXview-250, MXview-50, MXview-500• PoE Power consumption visualization.• Generate trend graphs to track bandwidth utilization and error packet rate statistics, which is accurate to four decimal points.• Device availability monitoring.• Supports third-party devices with MIB compiler and MIB browser.• Generates an inventory report for each device in the network.• Maintains device availability reports and records for up to 90 days.• Compiles comprehensive device properties reports.• Supports IE 6/8/9, Chrome 19, and Firefox 12.New FeaturesN/AN/ASupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/AN/AEnhancementsWindows 7, Windows 8, Windows Server 2008, Windows Server 2012, Windows XPMXview Upgrade-50, MXview-100, MXview-1000, MXview-2000, MXview-250, MXview-50, MXview-500• 2,000 nodes supported.• Virtual device panel.• Group visualization of VLAN and IGMP snooping.• Enhanced event playback interface.• Auto topology for end devices in the same subnet with MXview server.• Convenient device icon alignment tool.• New topology style and auto ring layout algorithm.• Core switches supported.New FeaturesN/AN/ASupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/AN/AEnhancementsWindows 7, Windows 8, Windows Server 2008, Windows Server 2012, Windows XP MXview Upgrade-50, MXview-100, MXview-1000, MXview-250, MXview-50, MXview-500• Network Event Playback.• 1-click mass operation of configuration and firmware.• Scheduling for routinely config backup.• Change history of configuration.• Comparison tool of two configuration files.• Grouping (multi-layer topology map).• NPort S8000 supported.New FeaturesN/AN/ASupported Operating SystemsNotesChangesApplicable ProductsBugs Fixed• UI enhancement.N/AEnhancementsWindows 7, Windows Server 2003, Windows Server 2008, Windows XPMXview Upgrade-50, MXview-100, MXview-1000, MXview-250, MXview-50, MXview-500• 1,000 nodes supported.• Grouping (2-layer topology map).• OPC 2.0-compliant.• Windows 7 and Server 2008 supported.• Device icons changeable.• Guest account.• SNMP Inform server.• Auto startup (Windows service).• AWK 3121 and AWK4121 supported.New FeaturesN/AN/ASupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/AN/AEnhancementsWindows Server 2003, Windows XPMXview Upgrade-50, MXview-100, MXview-250, MXview-50, MXview-500• Auto Topology (for LLDP devices).• Visualize Turbo Ring/Chain and port trunking.• Added SNMP trap as another way to collect events.• Notify users of events with SMS.• Notify local users of events with sounds and external programs.• More map operations, such as zoom or background image.• Comprehensive event history.• Export/import the system configurations.• Supports up to 20 nodes.New FeaturesN/AN/A。

相关主题
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

Kinco HMIware v2.2 Build140314主要改进:
发布时间:2014-3-14
新增/优化功能:
1.支持新屏:ET050
2.事件滚动条新增事件显示间隔功能,即两条事件信息间隔范围为1~7个像素
3.地址标签库新增可以通过地址进行排序的功能
4.宏变量属性框新增变量使用地址标签功能
5.滚动条新增滚动模式功能,卷动值1~100
6.KM5303屏新增编码器焦点绕过已映射元件的功能,当LB9915=ON,则转动左右旋钮无法选中已映射
元件,LB9915=OFF,则该功能失效
7.新增无效浮点数NAN显示旧值功能,当LB9920=ON,浮点数接收到无效数时会显示上次有效数据
8.新增VNC远程监控与操作功能,网页浏览功能需要用此版本软件更新内核和文件系统才支持,pc或
手机浏览不需要更新内核和文件系统
9.滚动条元件新增滚动功能
10.新增当前登录的用户名显示功能,文本元件LW9650~9665显示当前已登录的用户名
11.优化数据报表功能,原触发报表不支持周期采样,现触发报表可以选择周期采样
12.优化事件信息登录中内容为图形字体时导出生成csv文件不显示内容的问题,现图形字体内容的事件
导出生成的csv文件可以显示
备注:以上新功能使用说明,请查看《新功能说明》文档
新增/修改PLC驱动:
1.新增Bosch Rexroth L25 Ethernet Slave网口驱动,支持Bosch Rexroth L25
2.新增三菱Mitsubishi FX Series Ethernet(TCP Slave)网口驱动,支持FX3GE-24M PLC和FX3U-ENET-L
以太网模块
3.新增Toshiba S2PU72A Ethernet(TCP slave)网口驱动,支持Toshiba S2PU72A
4.优化Mitsubishi FX1S驱动,解决在某些旧型号屏中PLC通讯元件不显示,需随意触控屏才能显示的
问题。

低于v2.2(build140314)版本做的工程,用本版本软件打开工程后必须在HMI串口设置中点“恢复默认设置”,重新编译下载工程。

5.优化Mitsubishi Q series (CPU Port)驱动,增加支持三菱Q03UD PLC
6.优化AB CompactLogix EtherNet_IP Slave驱动,增加DINT寄存器
7.优化BACnet MSTP驱动,增加支持Johnson FC BUS设备
8.优化Modbus RTU Slave驱动,解决一个串口连多个主站设备时,高波特率通讯速度卡的问题
9.优化Keyence KV-1000驱动,解决plc通讯线插拔后重连,屏的通讯波特率还原为9600,与实际组
态中设置不同步的问题
10.优化Parker ACR9000串口驱动,解决与新4000屏通讯不上的问题。

11.修正SIEMENS S7-300_S7-400 (PC Adapter)驱动,停止位为2时,直接在线模拟失败的问题。

修正软件BUG:
1.修正HMI扩展属性中,当勾选上传工程,但密码为空时,能上传工程的问题,密码为空,不勾选,应
该是禁止上传
2.修正数值输入元件的字体tab大小变更(16-32),然后切到其它tab,再回到字体tab大小显示16的问

3.修正Unicode文本输入,制定Unicode输入字符串时,不按2次backspace文字不消失的问题
4.修正新4000屏初始化宏中访问LW10000以上时间寄存器错误的问题
5.修正KM5303屏元件条件显示或者不显示的时候,通过转动屏右上角旋钮仍能得到焦点并执行动作的
问题
6.修正KM5303上传大文件失败的问题
7.修正历史数据显示元件清除功能无效的问题
8.修正事件信息登录中双字寄存器值范围不对的问题
9.修正事件信息登录中触发功能设置不能保存的问题
10.优化SIEMENS MPI驱动直连通讯速度慢和187.5k波特率通讯不稳定的问题,此问题必须要用此版本
软件更新内核和文件系统重新编译下载工程才能解决
11.再次优化新4000屏矢量字体库有时无法加载的问题
12.修正宏变量为数组时,软件中编码格式选择BCD,但是重新打开变量属性框仍为BIN的问题,现该软
件中变量为数组时,编码格式不支持选择BCD,有错误提示
13.修正英文、韩文、俄文版软件自动弹出密码窗口,ASCII键盘显示异常的问题。

相关文档
最新文档