ASCO RB系列微型电磁阀测试系统
艾默生ASCO系列电磁阀使用说明书
AS218RX-A AS218TX-AAS218PX-A5014086002EN Instruction Sheet TR Bilgi DökümaniTW 安裝說明 CN安装说明ENThis is an OPEN TYPE module and therefore should be installed in an enclosure free of airborne dust, humidity, electric shock andvibration. The enclosure should prevent non-maintenance staff from operating the device (e.g. key or specific tools are required for operating the enclosure) in case danger and damage on the device may occur.FRCeci est un module ouvert et il doit donc être installé dans un coffret à l’abri des poussières, des vibrations et ne pas être exposé auxchocs électriques. Le boitier ou l’armoire doit éviter toute action d’un personnel autre que celui affecté à la maintenance de l’appareil (par exemple, clefs, outils spécifiques pour l’ouverture du coffret), ceci afin d’éviter tout accident corporel ou endommagement du produit).TRBu ürün AÇIK TİP bir modül olup toz, rutubet, elektrik şoku ve titreşimden uzak kapalı yerlerde muhafaza edilmelidir. Yanlış kullanımsonucu ürünün zarar görmesini önlemek için yetkili olmayan kişiler tarafından ürüne müdahale edilmesini önleyecek koruyucu önlemler alınmalıdır. (Ürünün bulunduğu panoya kilit konulması gibi).TW本機為開放型(OPEN TYPE )機種,因此使用者使用本機時,必須將之安裝於具防塵、防潮及免於電擊∕衝擊意外之外殼配線箱內。
ASCO电磁阀是什么
ASCO电磁阀是什么ASCO电磁阀是什么是以安全保障为前提的阀门,还有一些是压缩气体作为动力源进行控制的阀门,比如今天为大家举例的ASCO电磁阀,就是用来调节管道介质流量、压力、温度等等工艺参数的阀门,它们的特点是控制简单,反应快,而且性能稳定,不需要采取额外的保护措施就会达到不错的效果,那么接下来就和小编一起详细了解下关于这类ASCO电磁阀多方面的信息吧。
相信通过学习这方面的知识可以帮助我们产品的价值。
一、ASCO电磁阀选型建议1、明确气动调节阀在设备或装置中的用途,确定气动调节阀的工作条件:适用介质、工作压力、工作温度等等。
2、确定与气动调节阀连接管道的公称通径和连接方式:法兰、螺纹、焊接等。
3、确定气动调节阀的型式ASCO电磁阀等。
4、确定动作方式可分为:直行程和角行程两种方式。
5、选择ASCO电磁阀的种类:闭路气动调节阀、调节气动调节阀、安全气动调节阀等。
6、确定ASCO电磁阀的参数:对于自动气动调节阀,根据不同需要先确定允许流阻、排放能力、背压等,再确定管道的公称通径和阀座孔的直径。
7、确定操作ASCO电磁阀的方式:手动、电动、电磁、气动或液动、电气联动或电液联动等。
8、根据管线输送的介质、工作压力、工作温度确定所选气动调节阀的壳体和内件的材料:灰铸铁、可锻铸铁、球墨铸铁、碳素钢、合金钢、不锈耐酸钢、铜合金等。
二、ASCO电磁阀的工作原理ASCO电磁阀就是以压缩气体为动力源,以气缸为执行器,并借助于阀门定位器、转换器、电磁阀、保位阀、储气罐、气体过滤器等附件去驱动阀门,实现开关量或比例式调节,接收工业自动化控制系统的控制信号来完成调节管道介质的:流量、压力、温度、液位等各种工艺过程参数。
气动调节阀的特点就是控制简单,反应快速,且本质安全,不需另外再采取防爆措施。
以上为大家具体介绍的是关于气动调节阀多方面的知识,由此可以得知这些产品通过压缩气体为动力源,能够调节管道介质的流量、压力、温度等工艺过程参数,除此之外,气动调节阀可以提供多种多样尺寸规格的选择。
ASCO_电磁阀选型指南
ASCO_电磁阀选型指南引言:ASCO是一家全球领先的电磁阀制造商,其产品广泛应用于自动化控制系统中。
本文将为您介绍ASCO电磁阀选型的一般原则和注意事项,帮助您选择适合您应用需求的电磁阀。
一、了解应用需求:在选型之前,首先需要了解您的应用需求,包括工作介质、压力范围、温度范围、流量要求等。
这些信息将有助于确定电磁阀的材料选择和性能要求。
二、选择电磁阀类型:ASCO提供了多种类型的电磁阀,包括直动式电磁阀、弹簧复位式电磁阀、角位移电磁阀等。
根据应用需求选择适合的电磁阀类型。
1.直动式电磁阀:直动式电磁阀具有简单结构、可靠性高的特点。
适用于一般工作介质和中小流量场合。
根据工作原理的不同,直动式电磁阀又可分为两种类型:单向性和双向性。
在选择时,需要根据流体的流向确定所需的类型。
2.弹簧复位式电磁阀:弹簧复位式电磁阀适用于迅速切断工作介质流量的需求。
其具有高可靠性、快速响应的优点。
同时,由于采用了复位弹簧的设计,即使在气源中断的情况下也能保持阀门关闭状态。
3.角位移电磁阀:角位移电磁阀适用于大流量、高压力的场合。
其通过电机的转动来控制阀门的开合,具有响应速度快、换向灵活的特点。
但角位移电磁阀的结构比较复杂,维护和维修相对困难。
三、选择电磁阀材料:根据应用的工作介质和环境条件选择合适的电磁阀材料。
ASCO提供的电磁阀材料包括铜、不锈钢、铝合金等。
一般情况下,不锈钢是最常见的选择,因为它具有良好的耐腐蚀性能和强度。
四、选择电磁阀规格:根据应用的压力和流量要求选择合适的电磁阀规格。
ASCO的电磁阀规格包括DN15、DN20、DN25等,可根据具体需求进行选择。
五、选择电磁阀电压:根据应用的电源要求选择合适的电磁阀电压。
ASCO提供的电磁阀电压范围包括AC220V、AC110V、DC24V等。
需要注意的是,不同的电压对于电磁阀的开关速度和功耗有一定的影响。
六、考虑其他因素:在选择电磁阀时,还需要考虑其他因素,如防爆要求、密封性能、接口类型等。
ASCO_电磁阀选型指南
ASCO_电磁阀选型指南ASCO电磁阀是一种常用的控制元件,广泛应用于工业自动化领域。
选择合适的ASCO电磁阀对于系统的性能和可靠性具有重要影响。
本文将介绍ASCO电磁阀的选型指南,以帮助读者正确选择适合自己应用的电磁阀。
首先,选型之前需要明确的是,ASCO电磁阀的工作条件和要求是什么。
这包括工作温度范围、工作压力范围、压力介质、流量要求等。
根据这些条件和要求,可以确定所需要的电磁阀的基本参数。
其次,需要了解ASCO电磁阀的类型和工作原理。
ASCO电磁阀主要有直动式和先导式两种类型。
直动式电磁阀是通过电磁铁直接驱动阀芯,先导式电磁阀是通过导向阀驱动阀芯。
直动式电磁阀的响应速度更快,但压力损失较大;而先导式电磁阀的压力损失较小,但响应速度较慢。
根据实际需求选择合适的类型。
再次,需要考虑ASCO电磁阀的电气特性和电源要求。
ASCO电磁阀通常有直流和交流两种供电方式,工作电压一般为24V、110V或220V。
此外,还需要注意电磁阀的保护等级和绝缘等级,以确保其在特定的环境下安全可靠地工作。
此外,还需要考虑ASCO电磁阀的连接方式和安装方式。
常见的连接方式有螺纹连接、法兰连接和插装式连接等,根据实际情况选择合适的连接方式。
安装方式包括立式安装、卧式安装和倾斜安装等,根据实际需求选择合适的安装方式。
最后,还需要考虑ASCO电磁阀的品牌和性价比。
ASCO是一家知名的电磁阀制造商,其产品具有较高的品质和可靠性。
但是,在选择时还需考虑价格等因素,尽量选择性价比较高的产品。
总之,正确选择ASCO电磁阀对于系统的性能和可靠性具有重要影响。
希望本文的选型指南能帮助读者正确选择适合自己应用的ASCO电磁阀。
ASCO电磁阀产品说明
防护的识别
电气设备有一个与 EN50014 标准一致的记号:
EEx d IIB + H2 IP65
EEx 这个符号意味着这个电气设备遵守了一个或几个与 EN50015 到 EN50028 欧洲标准明确一致的保护种类
"d" : 隔爆型
"e" : 增安型 (EN 50019)
"i" : 本安型 "ia" "ib" (EN 50020)
zz
定义
根据标准规定,在特殊的条件下(正常使用和非正常使用的条 件下),所采用的线圈不会产生火花,同时其产生的热量又不 会引起环境爆炸。
最高表面温度
T1 = 450 °C T2 = 300 °C T3 = 200 °C T4 = 135 °C T5 = 100 °C T6 = 85 °C
EM solenoid
电气防爆基础
权威测试机构认证的产品标志 center-CENELEC (欧洲电子技术标准委员会)
EEx "ia" II C T6
符合欧洲标准的电气设 备标志
气体类型
例 II C: 乙炔
氢 II B : 乙烯 II A : 丙烷 I : 甲烷
防护类型
防护标志
"ia" "i"
"ib"
区域
012 zzz
ethylene ethyl oxide
hydrogen ethyl ether sulphide
IIC
(<20 μJ)
hydrogene
acetylene
-
-
carbon bisulphide
asco阀门安全仪表系统用电磁阀使用手册-iec 61508说明书
I&M V 9629 R6 Solenoid Valves used in SafetyInstrumented SystemsASCO Valves ®Page 1 of 7Table of Contents1 I ntroduction (3)1.1 Terms and Abbreviations (3)1.2 Acronyms (3)2 Designing a Safety Instrumented Function using an ASCO Solenoid Valve (4)2.1 Safety Function (4)2.2 Environmental limits (4)2.3 Application limits (4)2.4 Design Verification (4)2.5 SIL Capability (5)2.5.1 Systematic Integrity (5)2.5.2 Random Integrity (5)3 Installation and Commissioning (5)3.1 Installation (5)3.2 Response Time (6)4 Operation and Maintenance (6)4.1 Proof test without automatic testing (6)4.2 Proof test with automatic partial valve stroke testing (6)4.3 Repair and replacement (7)4.4 ASCO Notification (7)5 ASCO Solenoid Pilot Valves Covered (7)6 Status of the document (7)6.1 Releases (7)1 IntroductionThis Operating Manual provides the necessary information to design, install, verify and maintain a Safety Instrumented Function (SIF) utilizing an ASCO Solenoid Valve. This manual provides necessary requirements for meeting the IEC 61508 or IEC 61511 functional safety standards.1.1 Terms and Abbreviations• Process Valve Any valve that is used to control the flow of media being used in a process.For the purpose of this document, this is usually a 2-way valve whosemovement is being controlled by an actuator and pilot valve.• Pilot Valve A 3-way or 4-way valve that is used to send or remove pressurized mediato and from an actuator for the opening and closing of a process valve.• Direct Acting Refers to a solenoid valves main orifice that is opened and closed as adirect result of the solenoid valves electromagnetic movement when thecoil is energized and de-energized.• Indirect Acting Refers to a solenoid valve’s main orifice that is opened and closed as aresult of fluid flow being directed from the electromagnetic 3-way solenoidpilot.• Safety Freedom from unacceptable risk of harm• Functional Safety The ability of a system to carry out the actions necessary to achieve or tomaintain a defined safe state for the equipment / machinery / plant /apparatus under control of the system• Basic Safety The equipment must be designed and manufactured such that it protectsagainst risk of damage to persons by electrical shock and other hazardsand against resulting fire and explosion. The protection must be effectiveunder all conditions of the nominal operation and under single faultcondition• Safety Assessment The investigation to arrive at a judgment - based on evidence - of thesafety achieved by safety-related systems• Fail-Safe State The state where the solenoid is de-energized and its return spring holdsthe pilot in the closed position.• Fail Safe Failure that causes the valve to go to the defined fail-safe state without ademand from the process.• Fail Dangerous Failure that does not respond to a demand from the process (i.e. beingunable to go to the defined fail-safe state).• Fail Dangerous Undetected (DU) Failure that is dangerous and that is not being diagnosed byautomatic stroke testing.• Fail Dangerous Detected (DD) Failure that is dangerous but is detected by automatic stroke testing.• Fail No Effect Failure of a component that is part of the safety function but that has noeffect on the safety function.• Low Demand Mode Mode, where the frequency of demands for operation made on a safety-related system is no greater than twice the proof test frequency.1.2 Acronyms• FMEDA Failure Modes, Effects and Diagnostic Analysis• HFT Hardware Fault Tolerance• MOC Management of Change: These are specific procedures often done whenperforming any work activities in compliance with government regulatoryauthorities.• PFD AVG Average Probability of Failure on Demand• SFF Safe Failure Fraction, the fraction of the overall failure rate of a device thatresults in either a safe fault or a diagnosed unsafe fault.• SIF Safety Instrumented Function, a set of equipment intended to reduce therisk due to a specific hazard (a safety loop).• SIL Safety Integrity Level, discrete level (one out of a possible four) forspecifying the safety integrity requirements of the safety functions to beallocated to the E/E/PE safety-related systems where Safety Integrity Level4 has the highest level of safety integrity and Safety Integrity Level 1 hasthe lowest.• SIS Safety Instrumented System – Implementation of one or more SafetyInstrumented Functions. A SIS is composed of any combination ofsensor(s), logic solver(s), and final element(s).2 D esigning a Safety Instrumented Function (SIF) using an ASCOSolenoid Valve2.1 Safety FunctionWhen de-energized, the ASCO Solenoid Pilot Valve moves to its fail-safe position. Depending on the solenoid specified Normally Closed (NC) or Normally Open (NO), the valve will supply the fluid media or vent the fluid media depending on the piping of the installation. Please note that the solenoid pilot valve must be piped to the actuator in accordance with the manufacturer’s recommendations and allowable desired function.The valve is intended to be part of final element subsystem as defined per IEC 61508 and the achieved SIL level of the designed function must be verified by the designer.2.2 Environmental limitsThe environmental limits of each solenoid are specified in the products respective catalog and Installation & Maintenance Instructions. The designer of a SIF must check that the product is rated for use within the expected environmental limits.2.3 Application limitsThe application limits of an ASCO Solenoid are specified in the products respective catalog and Installation & Maintenance Instructions. It is especially important that the designer check for material compatibility considering on-site chemical contaminants and air supply conditions. If the solenoid valve is used outside of the application limits or with incompatible materials, the reliability data provided becomes invalid.2.4 Design Verification• A detailed Failure Mode, Effects, and Diagnostics Analysis (FMEDA) report is available from ASCO.This report details all failure rates and failure modes as well as the expected lifetime.•The achieved Safety Integrity Level (SIL) of an entire Safety Instrumented Function (SIF) design must be verified by the designer via a calculation of PFD avg considering redundant architectures, proof test interval, proof test effectiveness, any automatic diagnostics, average repair time and the specific failure rates of all products included in the SIF. Each subsystem must be checked to assure compliance with minimum hardware fault tolerance (HFT) requirements. The Exida exSILentia tool is recommended for this work.•When using an ASCO Solenoid in a redundant configuration, a common cause factor of 5% should be included in safety integrity calculations.•The failure rate data listed the FMEDA report is only valid for the useful life time of an ASCO Solenoid.The failure rates will increase sometime after this time period. Reliability calculations based on the data listed in the FMEDA report for mission times beyond the lifetime may yield results that are too optimistic, i.e. the calculated Safety Integrity Level will not be achieved.2.5 SIL Capability2.5.1 Systematic IntegrityThe product has met manufacturer design process requirements of Safety Integrity Level (SIL) 3. These are intended to achieve sufficient integrity against systematic errors of design by the manufacturer. A Safety Instrumented Function (SIF) designed with this product must not be used at a SIL level higher than the statement without “prior use” justification by end user or diverse technology redundancy in the design.2.5.2 Random IntegrityThe solenoid valve is a Type A Device. Therefore when used the only component in a final element subassembly, a design can meet SIL 3 @ HFT=1 and SIL 2 @ HFT=0.When the final element assembly consists of many components (solenoid valve, quick exhaust valve, actuator, isolation valve, etc.) the SIL must be verified for the entire assembly using failure rates from all components. This analysis must account for any hardware fault tolerance and architecture constraints.3 Installation and Commissioning3.1 Installation•The ASCO Solenoid valve must be installed per standard installation practices outlined in the Installation Manual.•The environment must be checked to verify that environmental conditions do not exceed the ratings.•The ASCO Solenoid must be accessible for physical inspection.•Instrument Air Filtration: These solenoids are intended for use on clean, dry air or inert gas filtered to50 microns or better. To prevent freezing, the dew point of the media should be at least 18°F(10°C)below the minimum temperature to which any portion of the clean air or gas system could be exposed.Instrument air in compliance with ANSI/ISA Standard S7.3-1975 (R1981) exceeds the above requirements and is, therefore, an acceptable medium for these valves.• It is the operator’s responsibility to only use design options such as latches, when it is safe to do so.• Typical 3-way pilot valve piping configurations:a. 1 out-of 1 – This is the most common pilot valve configuration used.b. 2 out-of 2 – This is commonly used for high availability applications. In the case that onesolenoid valve was to spuriously trip, the second solenoid still maintains the position of theactuator/process valve at its operating state. Both solenoids must close in order to shift theactuator/process valve to its non-operating state.3.2 Response TimeThe response time of a solenoid pilot valve will vary by design. The factors that affect response time are pilot valve orifice size, operating pressure, size of actuator, torque required to open and close process valve, and distance between pilot valve and actuator. It is the responsibility of the end user to use a pilot valve that delivers the correct opening and closing time of the process valve required for the application.4 Operation and Maintenance4.1 Proof test without automatic testingThe objective of proof testing is to detect failures within an ASCO Solenoid that are not detected by any automatic diagnostics of the system. Of main concern are undetected failures that prevent the safety instrumented function from performing its intended function.The frequency of proof testing, or the proof test interval, is to be determined in reliability calculations for the safety instrumented functions for which an ASCO Solenoid is applied. The proof tests must be performed more frequently than or as frequently as specified in the calculation in order to maintain the required safety integrity of the safety instrumented function.The following proof test is recommended. Any failures that are detected and that compromise functional safety should be reported to ASCO.Table 11Bypass the safety PLC or take other appropriate action to avoid a false trip, following company Management of Change (MOC) procedures2Inspect the external parts of the solenoid valve for dirty or clogged ports and other physical damage. Do not attempt disassembly of the valve.the 3De-energize the solenoid coil and observe that the actuator and valve move. Energize solenoid after a small movement of the valve.4Inspect the solenoid for dirt, corrosion or excessive moisture. Clean if necessary and take corrective action to properly clean the air supply. This is done to avoid incipient failures due todirty air.5Record a n y failures i n your c o m p a n y’s S I F i n s p e c t i o n d a t a b a s e. Restore the loop t o full operation.6Remove the bypass from the safety PLC or otherwise restore normal operationThis test will detect approximately 99% of possible DU failures in the solenoid (Proof Test Coverage).The person(s) performing the proof test of an ASCO Solenoid should be trained in SIS operations, including bypass procedures, solenoid maintenance and company Management of Change procedures. No special tools are required.4.2 Proof test with automatic partial valve stroke testingAn automatic partial valve stroke testing scheme that performs a full stroke of the solenoid valve and measures valve movement timing will detect most potentially dangerous failure modes. It is recommended that a physical inspection (Step 2 from Table 1) be performed on a periodic basis with the time interval determined by plant conditions. Maximum inspection interval is five years but an annual inspection is recommended.4.3 Repair and replacementAccording to section 7.4.7.4 of IEC 61508-2 a useful lifetime based on experience, should be assumed. General field knowledge suggests that most solenoid valves have a useful life of 3 to 10 years, but may be longer depending on the valve series and other factors.It is the responsibility of the end user to establish a preventative maintenance process to replace all solenoids before the end of the useful life.4.4 ASCO NotificationAny failures that are detected and that compromise functional safety should be reported to ASCO Valve. Please contact ASCO customer service.5 ASCO Solenoid Pilot Valves CoveredSelect ASCO valves from the following series have been evaluated per IEC 61508 parts 1 and 2 and covered under this document:∙8314 Series - 3-Way Direct Acting Pilot Valves∙8320 Series - 3-Way Direct Acting Pilot Valves∙8316 Series - 3-Way Indirect Acting Pilot Valves∙551, 552, 553 Series - 3 and 4-Way Indirect Acting Pilot Valves∙8317, 8320, 8321 Series - 3-Way Harsh Environment Pilot Valves∙327/8327 Series - 3-Way Direct Acting Pilot Valves.∙126 Series - 3-Way Direct Acting Pilot Valves.∙8317 Series – 3-Way Piloting Quick Exhaust valve∙307 Series - 3-Way Direct Acting Pilot Valves∙364 Series – 3-Way Spool Valves∙362/562 Series – 3-Way and 4-Way Spool Valves6 Status of the document6.1 ReleasesRevision: GECN Number: 264756Release status: V9629 Initial Release on 02/18/11。
美国ASCO电磁阀工作原理
美国ASCO电磁阀工作原理美国ASCO电磁阀工作原理上海维特锐应用领域:船舶工业大量耐盐雾,满足船用标准的液压环保设备城市污水及固体废物处理和综合利用设备,城市和工业噪声防治设备,以及大气污染治理设备石油化工设备天然气集输设备石油勘探和钻采设备/维修用量发电设备电液调速系统锅炉给水系统军工航空、航天工程类水利工程、汽车、摩托车自卸式汽车、平板车、高空作业车、汽车中的转向器、减振器等、智能机械折臂式小汽车装卸器、数字式体育锻炼机、模拟驾驶舱、机器人等、其它铁路、机车车辆、医药、印刷,以及游艺等机械设备.美国ASCO电磁阀工作原理电磁控制换向阀的工作原理在气动回路中,电磁控制换向阀的作用是控制气流通道的通、断或改变压缩空气的流动方向。
主要工作原理是利用电磁线圈产生的电磁力的作用,推动阀芯切换,实现气流的换向。
按电磁控制部分对换向阀推动方式的不同,可以分为直动式电磁阀和先导式电磁阀。
直动式电磁阀直接利用电磁力推动阀芯换向,而先导式换向阀则利用电磁先导阀输出的先导气压推动阀芯换向。
表示3/2(三路二位)直动式电磁阀(常断型)结构的简单剖面图及工作原理。
线圈通电时,静铁芯产生电磁力,阀芯受到电磁力作用向上移动,密封垫抬起,使1、2接通,2、3断开,阀处于进气状态,可以控制气缸动作。
当断电时,阀芯靠弹簧力的作用恢复原状,即1、2断,2、3通,阀处于排气状态。
ASCO电磁阀的功能特点:ASCO电磁阀为双阀瓣结构,阀杆不平衡力小,结构紧凑,用于供热(空调)水系统中,恒定被控系统的压差,并有以下的特点:1、恒定被控系统压差;2、支持被控系统内部自主调节;排除外网压差波动对被控系统的影响;3、采用的无级调压结构,控制压差可调比可达25:1;4、采用技术膜片,理论误差为零,且可承受0.8MPa的压差;5、当被控系统内部无自主调节时,该阀即具备了自力式流量控制阀的功能,设定流量的方法;a、调节控制压差的大小;b、调节被控系统阻力的大小;6、具备消除堵塞的功能,当控制压差z大时,阀门为全开状态,堵塞在双阀瓣处的污物会在介质压力下清除干净,方法是将导压管端的球阀关闭3-5分钟。
ASCO电磁阀选型依据
ASCO电磁阀选型依据ASCO电磁阀是一种常见的控制元件,广泛应用于工业自动化和流体控制系统中。
在使用ASCO电磁阀之前,我们需要正确选型以满足特定的应用要求。
本文将介绍ASCO电磁阀的选型依据,帮助读者正确选择ASCO电磁阀。
1. 应用场景首先,我们需要了解电磁阀的应用场景。
电磁阀常用于液压、气动、流体控制等应用领域,主要用于控制流体的流量、压力、方向和温度等参数。
在选择电磁阀之前,我们需要确定具体的应用场景以及所需控制的参数。
2. 电磁阀类型ASCO电磁阀根据其结构和控制方式的不同,分为多种类型。
常见的电磁阀类型有:•直通式电磁阀:通常由一个电磁铁和一个阀体组成,是一种较为简单的电磁阀类型,主要用于气体和液体控制。
•按钮式电磁阀:一般由较粗的磁铁和阀门组成,常用于车辆控制器等场合,具有较高的防尘性。
•中心式电磁阀:由一个电磁铁和一个可旋转的阀芯组成,常用于流体控制和自动化控制应用。
•薄膜电磁阀:主要由一个薄膜和一个弹簧组成,通常用于水处理、气动机械和工业自动化等领域。
在选型时,我们需要根据不同的应用场景,选择适合的电磁阀类型。
3. 电磁阀的通径通径是衡量电磁阀流量能力的一项指标,也是选型中的重要参数。
通径一般使用英寸(inch)或毫米(mm)来表示。
在选型时,我们需要正确估算流量大小并选择适合的通径。
如果通径过小,会造成流体的流量不足,影响控制效果;而通径过大,则会浪费资源,增加成本。
因此,我们需要根据具体的需求选择正确的通径。
4. 电磁阀的工作压力和介质电磁阀不仅需要承受流体的压力,在应用中还需要考虑介质的性质。
不同的介质对电磁阀的材质和防爆等要求也不同。
在选型时,我们需要确定液体或气体的工作压力和介质,并选择适合的材质和防爆等级,以保证电磁阀在特定环境下的安全可靠运行。
5. 电磁阀的电压和电流电磁阀的电压和电流也是选型中的重要参数。
通常来说,电磁阀的电压范围较为广泛,一般包括AC或DC电压。
asco电磁阀励磁型式
asco电磁阀励磁型式ASCO电磁阀励磁型式ASCO电磁阀是一种常用的控制元件,广泛应用于工业自动化系统中。
在ASCO电磁阀中,励磁是一个重要的环节,它决定了电磁阀的工作性能和可靠性。
ASCO电磁阀的励磁型式可以分为直流励磁和交流励磁两种。
一、直流励磁型式直流励磁是指ASCO电磁阀的励磁电源采用直流电源。
直流励磁型式具有以下特点:1.1 直流励磁电源直流励磁电源通常由直流电源或电池提供。
直流电源具有稳定的电压和电流输出,能够提供稳定的励磁电流给ASCO电磁阀。
电池作为备用电源,可以在停电情况下继续供电,确保电磁阀的正常工作。
1.2 励磁线圈直流励磁线圈是ASCO电磁阀中的关键部件,它接收来自励磁电源的直流电流,产生磁场,从而吸引或释放阀芯,控制介质的通断。
直流励磁线圈通常采用高导磁材料制成,具有良好的导磁性能和励磁效果。
1.3 励磁控制方式直流励磁型式的ASCO电磁阀可以采用手动控制、自动控制或远程控制。
手动控制时,通过手动开关或按钮控制励磁电源的接通和断开;自动控制时,可以通过自动控制系统根据预设条件自动控制励磁电源的开关;远程控制时,可以通过远程信号传输设备将控制信号传输到电磁阀所在位置,控制励磁电源的开关。
二、交流励磁型式交流励磁是指ASCO电磁阀的励磁电源采用交流电源。
交流励磁型式具有以下特点:2.1 交流励磁电源交流励磁电源通常由交流电源提供,电压一般为220V或380V。
交流电源具有稳定的电压和频率输出,能够提供稳定的励磁电流给ASCO电磁阀。
2.2 励磁线圈交流励磁线圈与直流励磁线圈不同,它采用交流电流进行励磁。
为了保证励磁效果,交流励磁线圈通常采用铁芯设计,提高导磁性能。
2.3 励磁控制方式交流励磁型式的ASCO电磁阀可以采用手动控制、自动控制或远程控制,与直流励磁型式类似。
不同的是,交流励磁电源需要通过交流接触器或继电器进行控制,实现励磁电流的接通和断开。
三、总结ASCO电磁阀的励磁型式主要包括直流励磁和交流励磁两种。
ASCO电磁阀的特点和优势
ASCO电磁阀的特点和优势
ASCO电磁阀是由ASCO Valve公司生产的一种电控阀,用于控制和调节流体的流动。
ASCO Valve是全球领先的流体控制解决方案供应商,其产品广泛应用于工业、制造、能源、化工、食品和饮料等行业。
ASCO电磁阀具有以下特点和优势:
1.可靠性:ASCO电磁阀采用高质量的材料和工艺制造而成,
具有卓越的耐用性和长寿命。
其设计和制造符合严格的质
量标准,确保阀门在不同工况下的可靠运行。
2.高效性能:ASCO电磁阀采用先进的设计和技术,具有快
速的响应和精确的控制能力。
它们能够快速开关,提供准
确的流量和压力控制,满足不同应用的需要。
3.多种型号和规格:ASCO电磁阀有多个系列和型号可供选
择,包括直动式、导向式、膜片式和旋塞式等不同类型。
它们有各种尺寸、电压和连接方式,可适应不同的管道和
介质要求。
4.广泛应用:ASCO电磁阀可用于多种流体控制应用,包括
液体、气体和蒸汽。
它们常用于自动化控制系统、冷却和
加热系统、液位控制、气体调压和过滤等领域。
总之,ASCO电磁阀是一种高品质的电控阀,具有可靠性、高效性能和广泛的应用范围。
使用ASCO电磁阀可实现流体的精确控制和自动化操作,提高系统的稳定性和效率。
asco比例阀说明书
asco比例阀说明书
ASCO比例阀是一种按比例控制的阀门,主要用于加强系统的调节作用。
以下是使用ASCO比例阀的一些基本步骤和注意事项:
1. 安装:根据实际需求,选择合适的型号和规格,按照制造商提供的指南进行安装。
请确保阀门的安装符合安全标准,并考虑潜在的流体阻力、温度和压力等因素。
2. 电源连接:将比例阀连接到合适的电源,确保电压和电流值与阀门的要求相匹配。
3. 控制器设置:比例阀需要一个控制器来按比例调节阀门的开度。
根据需要,设置控制器的参数,如增益、积分时间和微分时间等。
4. 测试:在系统上测试比例阀,确保其按比例地响应控制器的信号,并满足系统的需求。
5. 维护:定期检查比例阀的外观和性能,确保其正常工作。
根据需要,清洁、润滑或更换部件。
6. 注意事项:
在使用过程中,应避免过载,以免损坏阀门。
在进行任何维护或修理之前,务必关闭电源并释放压力。
在安装或更换部件时,应遵循制造商的指导,并确保所有连接牢固可靠。
在使用过程中,应定期检查系统的安全措施,以确保操作人员的安全。
以上是使用ASCO比例阀的一些基本步骤和注意事项。
具体的操作和设置
应根据实际情况和阀门的具体型号进行调整。
如有疑问或需要更详细的信息,请参考ASCO比例阀的制造商提供的用户手册或联系专业人员。
ASCO电磁阀只由少数几个零件组成
ASCO电磁阀只由少数几个零件构成ASCO电磁阀采用湿式沟通或DC电磁铁。
阀门通过电磁铁掌控阀芯的不同工作位置。
电磁铁断电时,阀芯靠弹簧压力保持在中心或终端位置(脉冲阀除外)。
电磁铁通电时,阀芯被推到工作位置,断电后又回到初始状态。
此时,用手按下故障检查按钮,移动阀芯。
由于湿式电磁铁内部与回油腔相通,电枢在油中运动,可以减少磨损和缓冲,提高散热性能,延长使用寿命。
沟通电磁铁具有动作时间短、电气掌控电路简单、无特殊触点保护的特点。
DC电磁铁具有软开关特性,工作频率高,对过载或低电压不敏感,工作可靠。
WE换向阀是由电磁铁掌控的滑阀式换向阀,紧要用于掌控液体的开关和流向。
ASCO电磁阀阀芯和阀体之间的节流面积及其产生的局部阻力调整流量,从而掌控执行器的运动速度。
依据用途,流量掌控阀有五种类型。
节流阀:调整节流面积后,运动ASCO电磁阀仿佛于直动式自力式掌控阀,其设定信号由指令器的设定弹簧设定。
假如阀后压力升高,则意味着膜头L以下的压力高于其上的压力,阀芯3上移,掌控阀的流通面积减小,阀后压力减小。
同时,作用在导向隔膜4上的压力也升高,而且其作用力大于由设定弹簧5供应的作用力,使得导向组件6移动而且挡板7移动。
靠近喷嘴8时,先导阀的输出压力降低,即膜头L上的压力降低,从而阀芯3向上移动,直到阀后的压力与设定弹簧的力平衡。
针阀2用于调整放大系数,过滤器9用于过滤介质中的颗粒杂质,以防止喷嘴堵塞。
另一种自力式压力掌控阀使用重锤作为设定。
重物通过杠杆连接在阀杆上,其重力放大后作用在阀杆上,而阀前或阀后的压力被膜转化为推力,膜也作用在阀杆上。
只有当两者平衡时,阀杆才不会移动。
ASCO电磁阀中有一个阀板,它既是敏感部件,又是动作执行器。
装置启动时,管道内显现冷却冷凝液,冷凝液通过工作压力推开阀板,快速排出。
冷凝水排出时,蒸汽进入疏水阀,蒸汽体积快速膨胀,蒸汽流速大于冷凝水流速,造成阀板上下压差,阀板在蒸汽流速的抽吸下快速关闭。
ASCO电磁阀的几种控制分类
ASCO电磁阀的几种控制分类压力控制用ASCO电磁阀控制压力的系统如图10-14所示。
当罐内压力达到额定值时,电接点压力表或压力开关电接点断开,电磁阀断电后关闭,罐内压力低时,电接点接通,电磁阀通电后开启,无论水源或气源的压力在补充,直至达到额定值。
除尘工艺管路控制用电磁阀控制除尘工艺管路系统如图10-15所示。
当尘埃超标时,报警器接通电源,电磁阀通电后开启,大管路充满水后,各小管路进行喷雾除尘,无尘埃时,报警器断电,电磁阀自动关闭。
m尘埃报警器用电磁阀控制除尘工艺管路工艺配比控制用电磁阀控制工艺配比系统如图10-16所示。
用液态配比控制仪,物料管路用S2电磁阀和S1水管路用电磁阀的开启和关闭来调整罐内的配比度。
推动液压缸或气动缸控制用电磁阀控制液压缸或气动缸系统如图10-17所示。
单电控二位四通(五)通电磁阀的工作孔其中有一个为常开工作孔,ASCO电磁阀在断电状态进气(液)孔 P的介质直接进人工作孔B,使液压缸或气动活塞推 ,当电磁阀通电时,直动二位四(五)通的ASCO电磁阀直接将铁芯阀杆提起关闭B工作孔,压力源的气体或液体通向A工作孔,使气动(液压)缸的活塞推向D端,该电磁阀可以通用。
先导式二位四(五)通ASCO电磁阀是靠先导孔的进压推动阀内的阀杆进行气(液)体的换向功能。
先导式二位四(五)通电磁阀在气体和液体介质中不能通用,因结构和密封形式不相同。
ASCO电磁阀的几种控制分类在不断完善已有产品的同时,ASCO还提供多元化产品及解决方案以符合各种对紧急电源切换应用的要求。
除广泛应用的开路式自动转换开关外,我们还研发了闭路切换开关CTTS、延迟切换开关DTTS、维修时仍可继续供应电力的旁路隔离抽出型开关ATB\ACTB、静态电子式高速切换不断电开关STS、闭路式线性加卸载切换系统SLTS、中压切换开关MVATS,MVCTTS、多电源切换系统、发电机并联系统、紧急电力管理系统、照明控制接触开关及暂态浪涌电压突波抑制器。
ASCO 电磁阀选型
一、ASCO电磁阀选型参数ASCO的电磁阀有很多种结构可供选择,能满足任何实际操作的需要,ASCO电磁阀有二通连接,三通连接,四通和五通连接,更有多种管接尺寸,范围1/4″到3″。
ASCO所有型号的阀都有多种阀体材料供选择;包括黄铜,铝,不锈钢和青铜等,根据所控制的流体的性质和所需的压力等级来选择。
为满足客户特殊应用的要求,ASCO提供了多种任选电气和结构特性:任选电气特性:。
用于高温环境的线圈。
线圈引线带片状端子和螺纹端子。
使用干电池的线圈。
敞开式电磁线圈。
从防雨到氢气环境下防爆的不同种类电磁线圈外壳任选结构特点。
手动操作器。
调节装置。
特殊清洁程序。
处理多种流体的特殊材料如何选择任选特性?1、表1列举出适用于各类电磁线圈的任选电气特性,指需在型号前加上这些前缀即可得到所需特性。
2、表2列出了适于各类阀门系列的任选结构特性,只需在型号后加上这些后缀即可得到所需特性。
3、关于其它列举的前、后缀及未列出的条件要求,请具体咨询我司。
(注:并非所有任选特性都适合于所有阀门。
)表1:任选电气特性之前缀:表2:任选结构特性后缀ASCO阀门型号及含有前后缀的实例如下:注:代表设计变化的英文字母表示较大的设计变化,影响到修理包,重建修理包和线圈。
每一变化后正确的替代零部件列在ASCO重建修理包和线圈的样本里,请具体查询。
二、ASCO电磁阀选型要领电磁阀选型首先应该依次遵循安全性,可靠性,适用性,经济性四大原则,其次是根据六个方面的现场工况(即管道参数、流体参数、压力参数、电气参数、动作方式、特殊要求进行选择)。
选型依据:一、根据管道参数选择电磁阀的:通径规格(即DN)、接口方式1、按照现场管道内径尺寸或流量要求来确定通径(DN)尺寸。
2、接口方式,一般>DN50要选择法兰接口,≤DN50则可根据用户需要自由选择。
二、根据流体参数选择电磁阀的:材质、温度组1、腐蚀性流体:宜选用耐腐蚀电磁阀和全不锈钢;食用超净流体:宜选用食品级不锈钢材质电磁阀。
ASCO电磁阀的结构原理 电磁阀工作原理
ASCO电磁阀的结构原理电磁阀工作原理ASCO电磁阀是用电磁控制的工业设备,用在工业控制系统中调整介质的方向、流量、速度和其他的参数。
常用的电磁阀是单向阀、安全阀、方向控制阀、速度调节阀等。
在气动系统中常用阀起的作用:ASCO单向阀让压缩空气从压缩机进入气罐,当压缩机关闭时,阻止压缩空气反方向流动;安全阀当储气罐内的压力超过允许限度,可将压缩空气排出;方向控制阀通过对气缸两个接口交替地加压和排气,来控制运动的方向;速度调节阀能简便实现执行元件的无级调速。
ASCO电磁阀的结构原理分类:1、ASCO直动式电磁阀有常闭型和常开型二种。
常闭型断电时呈关闭状态,当线圈通电时产生电磁力,使动铁芯克服弹簧力同静铁芯吸合直接开启阀,介质呈通路;当线圈断电时电磁力消失,动铁芯在弹簧力的作用下复位,直接关闭阀口,介质不通。
结构简单,动作可靠,在零压差和微真空下正常工作。
常开型正好相反。
2、ASCO分布直动式电磁阀该阀采用一次开阀和二次开阀连在一体,主阀和导阀分步使电磁力和压差直接开启主阀口。
当线圈通电时,产生电磁力使动铁芯和静铁芯吸合,导阀口开启而导阀口设在主阀口上,且动铁芯与主阀芯连在一起,此时主阀上腔的压力通过导阀口卸荷,在压力差和电磁力的同时作用下使主阀芯向上运动,开启主阀介质流通。
当线圈断电时电磁力消失,此时动铁芯在自重和弹簧力的作用下关闭导阀孔,此时介质在平衡孔中进入主阀芯上腔,使上腔压力升高,此时在弹簧复位和压力的作用下关闭主阀,介质断流。
结构合理,动作可靠,在零压差时工作也可靠。
3、ASCO间接先导式电磁阀该系列电磁阀由先导阀和主阀芯联系着形成通道组合而成;常闭型在未通电时,呈关闭状态。
当线圈通电时,产生的磁力使动铁芯和静铁芯吸合,导阀口打开,介质流向出口,此时主阀芯上腔压力减少,低于进口侧的压力,形成压差克服弹簧阻力而随之向上运动,达到开启主阀口的目的,介质流通。
当线圈断电时,磁力消失,动铁芯在弹簧力作用下复位关闭先导口,此时介质从平衡孔流入,主阀芯上腔压力增大,并在弹簧力的作用下向下运动,关闭主阀口。
各种ASCO电磁阀工作原理及阀优缺点
各种ASCO电磁阀工作原理及阀优缺点各种ASCO电磁阀工作原理及阀优缺点是指关闭件ASCO电磁阀沿通道轴线的垂直方向移动的阀门,在管路上主要作为切断介质用,即全开或全关使用。
一般,闸阀不行作为调整流量使用。
它可以适用低温压也可以适用于高温高压,并可依据阀门的不同材质。
但闸阀一般不用于输送泥浆等介质的管路中。
优点:①流体阻力小;②启、闭所需力矩较小;③可以使用在介质向两方向流淌的环网管路上,也就是说介质的流向不受限制;④全开时,密封面受工作介质的冲蚀比截止阀小;⑤形体结构比较简洁,制造工艺性较;⑥结构长度比较短。
缺点:①形状尺寸和开启高度较大,所需安装的空间亦较大;②在启闭过程中,密封面人相对摩擦,摩损较大,甚至要在高温时简单引起擦伤现象;③一般闸阀都有两个密封面,给给加工、研磨和修理增加了一些困难;④启闭时间长。
2、ASCO电磁阀是用圆盘式启闭件往复回转90左右来开启、关闭和调整流体通道的一种阀门。
优点:①结构简洁,体积小,重量轻,耗材省,别用于大口径阀门中;②启闭快速,流阻小;③可用于带悬浮固体颗粒的介质,依据密封面的强度也可用于粉状和颗粒状介质。
可适用于通风除尘管路的双向启闭及调整,广泛用于冶金、轻工、电力、石油化工系统的煤气管道及水道等。
缺点:①流量调整范围不大,当开启达30%时,流量就将进95%以上;②由于蝶阀的结构和密封材料的限制,不宜用于高温、高压的管路系统中。
一般工作温度在300℃以下,PN40以下;③密封性能相对于球阀、截止阀较差,故用于密封要求不是很高的地方。
3、球阀:是由旋塞阀演化而来,它的启闭件是一个球体,利用球体绕阀杆的轴线旋转90实现开启和关闭的目的。
球阀在管道上主要用于切断、安排和转变介质流淌方向,设计成V形开口的球阀还具有良的流量调整功能。
优点:①具有低的流阻(实际为0);②因在工作时不会卡住(在无润滑剂时),故能牢靠地应用于腐蚀性介质和低沸点液体中;③在较大的压力和温度范围内,能实现*密封;④可实现快速启闭,某些结构的启闭时间仅为0.05~0.1s,以能用于试验台的自动化系统中。
分别介绍美国ASCO电磁阀的结构特点与工作原理以及安装
分别介绍美国ASCO电磁阀的结构特点与工作原理以及安装一、简介美国ASCO电磁阀是一种用于掌控液体和气体流动的电掌控元件。
作为一种广泛应用的自动化设备,电磁阀广泛应用于各种工业领域,如石油、化工、航空、军事、水处理、制药、食品等领域。
在现代工业自动化系统中,ASCO电磁阀通常是起掌控作用的中央元件之一、二、结构特点美国ASCO电磁阀的结构包括导管、活塞、阀门和线圈。
其结构特点如下:1.导管——由高质量的铜或不锈钢制成,具有优越的耐用性和防腐性能;2.活塞——是电磁阀的核心部件,其功能在于隔断或通导流体管道;其通常由高强度的不锈钢材料制成,具有良好的抗腐蚀性和耐久性;3.阀门——也称作永磁核,由铜制成,并通过电磁力与活塞密封,防止流体漏出;4.线圈——紧要由高质量的铜线和里芯构成,其作用在于产生磁场,以掌控活塞的移动;三、工作原理美国ASCO电磁阀的工作原理是依靠电信号驱动,通过电磁铁产生的磁场来掌控阀门的状态,从而达到管道中的流体掌控。
实在来说,当电磁铁通电时,纵向线圈内电流产生磁力,使得阀门铁芯处于吸合状态,此时活塞和阀门吻合,流体被阀门和活塞隔开,阀门关闭状态被保持。
相反,当电磁铁断电时,吸合力减弱,阀门闭合弹簧将其关闭,此时,活塞会脱离阀门,流体开始流动。
美国ASCO电磁阀可以依据需要单独安装,也可以与其他设备一起搭配使用。
在不同的工业场合,需要设计不同的电磁阀掌控方案,以实现掌控和调整流量等功能。
四、安装美国ASCO电磁阀的安装应当遵守以下基本要求:1.电磁阀应当安装在水平或者垂直管道上;2.安装时应当确保流体的进出方向与电磁阀的正负极相匹配;3.安装前应当清洗管道,并确保管道内部没有异物或者污垢;4.安装时应当使用密封垫等密封材料,以防止漏水;5.安装后应当进行试运行和调试操作,确保电磁阀的工作正常。
除此之外,当需要进行维护时,需要通过拆除连接螺栓和管道来拆卸电磁阀。
在拆卸时,应当遵奉并服从相应的拆卸步骤和要求,以保证拆卸的正常进行,并防止损坏电磁阀。
asco电磁阀531原理
asco电磁阀531原理
(实用版)
目录
1.ASCO 电磁阀概述
2.ASCO 电磁阀 531 的组成部分
3.ASCO 电磁阀 531 的工作原理
4.ASCO 电磁阀的应用领域
正文
一、ASCO 电磁阀概述
ASCO 电磁阀是一种利用电磁力控制流体的开启和关闭的自动化基础元件,广泛应用于工业和商业环境中的流体控制应用。
ASCO 作为一家专业的流体控制阀及气动控制元件生产商,其产品范围从二位开关阀到影响数千用户的流量控制系统。
二、ASCO 电磁阀 531 的组成部分
ASCO 电磁阀 531 主要由以下几个部分组成:
1.调节螺栓:用于调节阀门的开启程度,从而控制流体的流量。
2.执行机构箱体:包含气缸体、气缸轴、活塞等部件,是气动执行机构的主要部分。
3.曲臂:通过活塞的运动带动曲臂进行 90 度回转,实现阀门的自动启闭。
4.连杆:连接曲臂和万向轴,将曲臂的运动传递给万向轴。
5.万向轴:连接曲臂和执行机构箱体,传递曲臂的运动,实现阀门的启闭。
三、ASCO 电磁阀 531 的工作原理
ASCO 电磁阀 531 采用压缩空气作为动力源,通过气动执行机构的运动,带动阀门实现自动启闭。
当电磁线圈通电后,产生电磁力,吸引衔铁使阀门打开;断电后,电磁力消失,衔铁回到原位,阀门关闭。
通过调节调节螺栓,可以改变阀门的开启程度,从而控制流体的流量。
四、ASCO 电磁阀的应用领域
ASCO 电磁阀 531 广泛应用于各种工业和商业环境中,如化工、石油、冶金、电力、水处理、环保、制药等。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
ASCO RB 系列微型电磁阀测试系统
目录 概述 产品质量要求 测试原理 系统结构 测试回路 系统配置 测试流程 测试软件 概述 ASCO RB 系列微型电磁阀广泛应用于医疗设备、 分析仪器和工业应用中的液体和气体的精确和可靠的控制等领域。 其工作性能的可靠性直接影响到所支持设备的安全和质量。基于 NI 的软硬件平台,我们开发了微型电磁阀柔性测 试系统,以实现电磁阀的闭漏、开漏、功率、流量、频率等参数的测试。可配置的工作参数,能够适应不同的测试 需求。 产品质量要求 Flow 1-2>6.7slpm w/3psig and 4.4vdc Flow 2-3>6.7slpm w/3psig De-energized leak (all stations)<1sccm w/3psig Energized leak (individual stations)<0.5sccm w/3psig and 4.4vdc 测试原理 电气功能测试:根据对电磁阀电源输入端的电流进行检测,判断电磁阀的电源接头的电气性能是否良好。 工作性能测试:根据对工作回路流量的检测,对电磁阀的各项功能进行验证,根据功能测试用例,逐项测试,检查 电磁阀是否达到用户要求的功能。 泄漏测试:依据质量流量技术,将通过层流元件的空气质量转换成泄漏值。如果工件泄漏,标准件与此泄漏间会产 生流量,通过质量流量转换成泄漏值,如立方厘米的 ATM/小时。 系统结构 RB 系列电磁阀测试系统包括控制和测试两大部分。 控制部分包括:工控机、数字 I/O 卡、可编程电源、比例阀、电磁阀、继电器。实现以下功能: 控制比例阀的开度 控制可编程电源的输出电压 控制测试回路所有电磁阀的开关 控制所有继电器的通断 检测所有压力传感器的信号 读取质量流量计的数值 检测所有按钮的开关信号 检测开关电源的输出电压 检测所有电磁阀的输入电流
测试部分包括:工控机、数据采集卡、压力传感器、质量流量计。实现以下功能:
测试回路
系统配置 概要 Signal Type AI AO DI DO Valve Tester 28 2 3 19
详情 Analog Inputs 7 Pressure Sensors 1 Power Supply Voltage 6 Valve Current -----------------------------------Total Required AI Channels=14*2=28 Analog Outputs 1 E/P 1 Power Supply -----------------------------------Total Required AO Channels=2 Digital Inputs 2 Push Buttons 1 Abort Buttons -----------------------------------Total Required DI Channels=3 Digital Outputs 6 Control Valves 6 Dump Valves 1 Valve across Leak Meter 6 Valve Relays -----------------------------------Total Required DO Channels=19
流程图:
电气功能测试
阀组通电泄漏测试
阀组不通电泄漏测试
Yes
合格? No 单阀通电泄漏测试
单阀不通电泄漏测试
合格? No
Yes
Port3密封单阀通电泄漏测试
Port3密封单阀不通电泄漏测试
合格? Yes 打印序列号
No
测试结束
© BAAIS
测试软件 软件界面:
功能描述: 左边区域为 RB3-0168 电磁阀的测试流程。当测试流程进行到某一步骤时,左边的指示灯将点亮,表示正在测试该 功能。右边指示灯用来指示测试结果,绿色代表 OK,红色代表 NOK。测试结束后,如果产品性能 OK,则打印产 品序列号。 右边区域为功能按钮、配置文件与结果统计。 上方“Configuration”按钮可调用配置程序,对产品的工作参数进行自定义配置,并存储在文件中。 上方“Calibration”按钮可调用传感器校准程序,对压力传感器进行校准,校准信息存储在文件中。 中部“Start Test”按钮用来控制测试流程的开始,与测试台上两个开始按钮复用。 中部“E-Stop”按钮用开控制测试流程的中断,与测试台上急停按钮复用。 右侧“Configuration File”文件选择控件可供用户测试前选择相应的产品配置文件,加载产品工作参数。 右侧“Calibration File”文件选择空间可供用户测试前选择传感器校准文件,加载压力传感器校准信息。 下方为测试结果统计, 包含测试日期, 测试总数, OK 总数和比例, NOK 总数和比例, 电气功能 NOK 总数和比例, 外部泄漏 NOK 总数和比例,3 口泄漏 NOK 总数和比例。
测试流程 阀组通 4.4VDC 电源,2 口左侧的 2 通密封阀打开,2 口右侧的 2 通密封阀打开,3 口的 2 通密封阀关闭,主 回路的 2 通密封阀打开,泄漏传感器两边的阀门关闭,控制比例阀,对 1 口供气(3psi) ,读取流量传感器的 值,如果>6.7slpm 为合格,否则为不合格; 阀组通 4.4VDC 电源,2 口左侧的 2 通密封阀关闭,2 口右侧的 2 通密封阀打开,3 口的 2 通密封阀打开,主 回路的 2 通密封阀打开,泄漏传感器两边的阀门关闭,控制比例阀,对 1 口供气(3psi) ,读取流量传感器的 值,如果>6.7slpm 为合格,否则为不合格; 阀组通 4.4VDC 电源,2 口左侧的 2 通密封阀关闭,2 口右侧的 2 通密封阀打开,3 口的 2 通密封阀关闭,主 回路的 2 通密封阀关闭,泄漏传感器两边的阀门打开,控制比例阀,对 1 口供气(3psi) ,读取泄漏传感器的 值,如泄漏量<3sccm 为合格,否则为不合格; 阀组不通电, 2 口左侧的 2 通密封阀打开,2 口右侧的 2 通密封阀打开,3 口的 2 通密封阀打开,主回路的 2 口密封阀关闭, 泄漏传感器两边的阀门打开, 控制比例阀, 对 1 口供气 (3psi) , 控制比例阀, 对 1 口供气 (3psi) , 读取泄漏传感器的值,如泄漏量<1sccm 为合格,否则为不合格; 如果阀组测试结果为不合格,则进行单阀测试;如合格则打印序列号,结束测试; 单阀测试步骤 1:单阀依次通 4.4VDC 电源,2 口左侧的 2 通密封阀依次关闭,2 口右侧的 2 通密封阀依次打 开,3 口的 2 通密封阀依次关闭,主回路的 2 通密封阀关闭,泄漏传感器两边的阀门打开,控制比例阀,对 1 口供气(3psi) ,读取泄漏传感器的值,如泄漏量<0.5sccm 为合格,否则为不合格; 单阀测试步骤 2:不通电,2 口左侧的 2 通密封阀依次打开,2 口右侧的 2 通密封阀依次打开,3 口的 2 通密 封阀依次打开,主回路的 2 通密封阀关闭,泄漏传感器两边的阀门打开,控制比例阀,对 1 口供气(3psi) , 读取泄漏传感器的值,如泄漏量<0.3sccm 为合格,否则为不合格; 如果单阀测试结果为不合格,则进行 Port3 测试; Port3 测试:用户打开夹具,在 Port3 插入封板,重复单阀测试步骤; 测试完成。