PLM安装配置手册

合集下载

金蝶K3 WISE创新管理平台PLM V12.2 光盘版安装说明

金蝶K3 WISE创新管理平台PLM V12.2 光盘版安装说明

3 初始化帐套
3.1 创建空数据库
在 SQL Server 数据库上创建两个新数据库 PLM 和 PIM,PLM 为 PLM 程序数据库,PIM 为消息数据库。
3.2 运行 PLMUpgrade.exe
打开 PLM 安装目录,选择\Tools\PLMUpgrade 如:C:\Program Files\kingdee\K3PLM22\Tools\PLMUpgrade 运行 PLMUpgrade.exe
右键“我的电脑”计算机管理本地用户和组,把 ASPNET 用户及 NETWORK SERVICE 用户添 加到 Administrators 角色组
第 11 页 共 31 页
DOC ID: KPSP_RM01_12_T01_K3 用户手册_V1.0
重启服务器
第 12 页 共 31 页
DOC ID: KPSP_RM01_12_T01_K3 用户手册_V1.0
3 初始化帐套 ...................................................................................................... 13
3.1 创建空数据库..................................................................................................................................13 3.2 运行 PLMUpgrade.exe ....................................................................................................................13

用友PLM安装使用说明书

用友PLM安装使用说明书

用友PLM安装使用说明配置篇:安装用友PLM前,请先阅读以下内容:本安装程序支持的环境:操作系统:支持Windows 2000,Windows2003服务版,必须安装有IIS(文件服务器必须安装)。

数据库服务:支持SQL SERVER2000 Sp3;SQL SERVER 2005(开发版要注意1433端口是否打开)安装注意事项:A:如果SQL SERVER 为2005,请手动创建、还原数据库,Ftp也需手动创建,配置。

然后在配置界面中可使用保存配置信息,进行数据库信息设置和打包程序。

(具体可参考“配置安装说明4 保存配置信息”部分)B:数据库安装登陆请使用混合模式,不能只使用Windows身份验证。

C:如果配置工具中读取不到sqlserver信息,需启动SQL Agent服务(打开企业管理器服务端,下拉选择Sql Agent,启动)。

D:还原数据库文件不要放到桌面上,放到具体盘符下,否则数据库用配置工具还原不了。

安装步骤:1.运行installer.exe.2.最好选用典型安装:3.可修改默认安装位置:4.其他选用默认安装设置即可.5.加密狗安装程序可以选择安装,也可以取消.6.该类似文件选择否:7.完成安装时,建议选择重新启动系统,以确保相关功能可成功操作。

配置安装说明:1.安装完成后,从开始菜单\程序\ufidaplm\配置工具,打开配置工具,进行数据库创建、设置和ftp设置:2.执行配置工具,打开下面的配置界面:先输入数据库用户名和数据库密码,再选择数据库服务器名称。

(这是此配置界面的必要操作)先创建数据库:在数据库名称中填写一个新的数据库名称。

点击,提示创建成功:3.还原数据库:点击,打开下面的界面,选择数据库文件(请确定该数据库备份文件在所使用的SQLSERVER所在机器上):点击“打开”按钮,系统自动还原,数据库成功还原:4.保存配置信息:本功能实现写入发布使用数据库信息及程序打包功能。

PLM使用手册

PLM使用手册

PLM使用手册(版本1.0 编制:房臣)目录1前言 (3)2系统准备 (3)3 PLM安装以及注册 (3)3.1 中望CAD的安装以及配置: (4)1)安装中望CAD系统 (4)2)激活中望CAD系统 (4)3)配置中望CAD模板 (4)4)常见问题 (5)3.2 PLM与中望CAD的接口的安装 (5)1)检查安装环境 (5)2)安装接口软件 (5)3)常见问题 (6)3.3接口软件的配置 (6)1)配置启动方式 (6)2)配置使用环境 (7)3)登录PLM系统 (8)4)常见问题 (9)3.4 PLM网页系统的安装 (10)1)下载并安装控件 (10)2)登录网页系统 (11)3)常见问题 (11)3.5 PLM系统使用要求 (11)4 PLM接口软件的使用 (12)4.1 图纸明细表 (12)1)填写要求 (12)2)填写步骤 (12)3)常见问题 (14)4.2 图纸上传 (14)1)上传规则 (14)2)操作步骤 (14)3)常见问题 (15)5 PLM系统的使用 (17)5.1 物料申请 (17)1)新建申请单 (17)2)填写申请单 (18)3)启动流程 (19)4)审核 (19)5.2 图纸下载 (19)1)下载方法 (19)2)常见问题 (19)5.3 生成BOM (20)1)操作步骤 (20)2)常见问题 (22)5.4 图纸的修改 (23)1)操作步骤 (23)6 工艺模块的使用 (23)6.1 物料添加 (24)6.2 跳层的设置 (25)6.3 BOM导入ERP (26)6.4 P-BOM更改 (27)7生产BOM的输出 (27)8补充说明 (27)8.1 项目总图 (27)8.2 其他说明 (29)1前言PLM系统是伴随着生产信息化而产生的一种信息平台。

与传统模式相比,该系统的主要优点是信息传递准确、信息记录完整,实现信息在多部门之间的无误流转,有利于综合控制效率、质量、成本。

PLM客户端安装配置手册

PLM客户端安装配置手册

目录1概述 (1)2安装准备 (1)3系统配置 (1)3.1Hosts文件配置 (1)3.2客户端与服务端时间同步(测试阶段不用) (1)3.3安装Adobe Acrobat 7.0 Professional (3)3.4JAVA软件安装 (3)3.5IE编码设置 (6)3.6加入本地安全站点 (7)4WINDCHILL应用配置 (9)4.1 ProductView安装 (9)4.2 首选项设置 (18)1概述本文档用于指导PLM系统客户端安装配置,在系统开始使用前,按此文档对客户端进行检查和配置。

2安装准备硬件环境:内存512M以上软件环境: Windchill XP SP2及最新补丁浏览器:IE6.0 SP2+JAVA:JAVA1.6+设计环境:Pro/E Wildfire4 M100+,Adobe 7 +,Java1.6+3系统配置3.1Hosts文件配置WinXP用户:在c:\windows\system32\drivers\etc\hosts文件中添加:172.20.109.66 注:根据实际情况配置,如果服务器变动以信息管理部提供的更新信息为准。

3.2客户端与服务端时间同步双击电脑任务栏右下角时间显示点击“Internet Time”标签页输入同步的服务器。

点击“Update Now”提示同步成功!完成同步。

注:部分客户端操作系统以上界面可能有所不同,也可以采用手工同步本机的时间与eqc1域相同。

3.3安装Adobe Acrobat 7.0 Professional典型安装(略)JAVA软件安装1) 登录系统登录/Windchill/初始用户名为工作证号2) 点击“主页”→“实用程序”→“软件下载”3) 点击“Productview 安装”4) 点击“java Jre 1.6”下载5) 运行下载程序,选择先保存到本地,再运行安装,选择“典型安装”(略)3.4IE编码设置打开IE,在工具->Internet选项->“高级”选项卡里,将总是以UTF-8发送URL(需要重启动)的打勾去掉。

金蝶K3 WISE创新管理平台 PLM V121 系统配置操作手册

金蝶K3 WISE创新管理平台 PLM V121 系统配置操作手册

金蝶K/3WISE创新管理平台PLM 系统配置1.1配置信息1.1.1业务类型界面:上图所示名词解释:【业务类型】:对数据管理的一种分类,包括:文档、PBOM、工装、项目、ECR、任务、设备、业务表单、DCN/ECN、问题集等。

系统的很多业务规则需要在数据的分类下设置,如编码规则、数据属性显示、版本规则等;业务类型支持多层分类;鼠标右键新建类型,如下图所示:1.1.1.1.文档A分配规则名词解析【文档名检查规则】:勾上“文档名不允许重复”,则在文档库导入文件时判断系统中是否已经存在相同文档名称的文档,如果有存在则不予导入。

【物理文件名检查规则】:勾上“物理文件名不允许重复”,则在文档库导入文件时判断系统是否已经存在相同文件名的文档,如果有存在则不予导入。

【文档库列表查询】:勾上“文档库列表查询是否查找流程附件的文档”,则在文档库列表查询文档时会将满足条件的流程附件也查询出来。

【文档库选择页查询】:勾上“文档选择页查询是否查找流程附件的文档”,则在文档选择页查询文档时会将满足条件的流程附件也查询出来。

B 基本信息【类型编码】:编码不能重复,为手工录入,支持中文;【类型名称】:名称不能重复,为手工录入,支持中文;【编码规则】:需要在“配置信息--编码规则”中定义后才能选择;【版本分隔符】:大小版本间的分隔符,如A.1中的“.”;【大版本序列】:需要在“配置信息—序列管理”中定义后才能选择,如A.1中的“A”;【小版本序列】:需要在“配置信息—序列管理”中定义后才能选择,如A.1中的“1”;【是否显示缩略图】:在文档属性界面出现“缩略图”,供浏览;C 业务类型分配规则名词解析【文档名检查规则】:勾上“文档名不允许重复”,则在文档库导入文件时判断系统中是否已经存在相同文档名称的文档,如果有存在则不予导入;【物理文件名检查规则】:勾上“物理文件名不允许重复”,则在文档库导入文件时判断系统是否已经存在相同文件名的文档,如果有存在则不予导入;D分配显示字段【显示】勾选即表示文档属性栏中有显示;【字段名称】系统后台的字段名称;【只读】勾选表示该字段内容在文档生成后为只读状态,一般操作不能修改内容;【预览】勾先表示不需进入文档的属性页面,只需打开文件夹,选择一份文档就可以在列示的文档列表下方就可以看到此字段;【必填】勾选表示该字段带“*”,为必填项;【Simplified】简体中文,系统前台的字段名称;内容修改后文档的属性名称一齐改变;【Traditional】繁体中文,系统前台的字段名称;内容修改后文档的属性名称一齐改变;【English】英文名,系统前台的字段名称;内容修改后文档的属性名称一齐改变;【】调整字段在文档属性界面的排列顺序;E 设置扩展字段名词解析:【扩展字段】即扩展属性,一般系统提示的常规属性不能满足要求的可作定义;【字段编码】手工录入,支持中文【字段名称】文档属性界面所显示来的属性名称【字段类型】目前类型有:字符串、日期、浮点、整数、文本、布尔【长度】属性内容所支持的字段长度;【内容来自枚举】当类型选择“字符串”时,可从“枚举管理”中选择定义好的枚举;【内容必填】勾选表示该字段带“*”,为必填项;【在预览页中显示】勾先表示不需进入文档的属性页面,只需打开文件夹,选择一份文档就可以在列示的文档列表下方就可以看到此字段;【在列表中显示】勾先表示在文档库选择列表中显示此字段;【】删除该条信息;【】修改该条信息的内容;【】调整字段在文档属性界面的排列顺序;F 数据对应关系名词定义:【数据对应关系】应用于特殊文档的集成,配置文档的参数与PLM物料常规属性建立对应关系【文件类型】受“配备信息—文件类型”及“关联文件类型”约束;【文件标识名称】所集成软件中定义的参数字段;【字段名称】PLM系统中所对应的字段名称;【对应关系为索引内容】以此字段来判断系统中是否已存在该文档;【文档关联物料索引】以此字段来判断系统中是否已存在该物料;G 关联文件类型【文件类型】在“配置信息→文件类型”中可定义,在导入文件时,根据所配置的文件类型自动筛选所对应格式的文件;H 关联流程模板【关联流程模板】关联流程模板后,当该业务类型文件启动流程时自动加载所关联的流程模板;【添加】从“流程模板”中选择要关联的流程模板;I文档模板名词定义:【文档模板】设置业务类型下的文档模板;【新建模板】添加新的模板,为未加载物理文件的空白文档;【注册】加载物理文件,形成真正有效的文档模板;1.1.1.2.PBOM名词定义:【基本信息】定义该类型的编码规则、版本规则等,与1.1.1.1文档类似;【分配显示字段】可参考1.1.1.1文档部分;【设置扩展字段】可参考1.1.1.1文档部分;1.1.1.3.工装名词定义:【基本信息】定义该类型名称、编码等,与1.1.1.1文档类似;【分配显示字段】可参考1.1.1.1文档部分;【设置扩展字段】可参考1.1.1.1文档部分;1.1.1.4.项目名词定义:【文档特征默认设置】值有“项目名称”、“项目编码”、“自定义”;若值为“项目名称”,同时项目模板中已导入文档或表单,则在引用项目模板生成项目后,文档或表单名称前自动添加“项目名称”;若值为“项目编号”,同时项目模板中已导入文档或表单,则在引用项目模板生成项目后,文档或表单名称前自动添加“项目编号”;若值为“自定义”,同时项目模板中已导入文档或表单,则在引用项目模板生成项目时,新建界面上就会出现一个输入“自定义”内容的文本框,项目新建成功后文档或表单名称前自动添加上“自定义”内容。

金蝶WISEPLM安装说明(win7版)精品PPT课件

金蝶WISEPLM安装说明(win7版)精品PPT课件
数据库:
SQL Server 2000 +SP4 或 SQL Server 2005+SP3(推荐使用)
环境要求:
IIS7.0 Microsoft. Net Framework.3.5SP1 及 Microsoft Chart Controls for Microsoft .net framework 3.5
在此与大部分软件的安装类似,全部按下一步。
版权所有 ©1993-2010 金蝶软件(中国)有限公司
P9
生成 PLM web 站点
安装完PLM程序后,会自动跳到建立站点的步骤。
在此表单的站点名称必须为图中的名称。
如非第一次安装,请先将原表单的名称改名并在IIS中 删除表单站点
版权所有 ©1993-2010 金蝶软件(中国)有限公司
P21
Demo数据恢复
至此PLM演示系统已经安装完毕,如果想恢复 演示版数据可按下列操作进行
在PLM系统原始安装盘目录下:HELP\DEMO 解压缩“K3 WIES PLM 演諕账套.rar”
恢复方法: 1、将FTP目录下文件夹覆盖C:\PLMvalut 下文件夹 2、将xsn_template文件夹覆盖C:\PLMvalut 下文件夹 3、恢复数据库:PLM、PIM (只支持SQL2005)
1.选择访问数据库模式为混合验证模式 并设置默认用户SA的密码(一定要设置密码)。
2.安装SQL Server2000 SP4或 SQL Server2005 SP3
版权所有 ©1993-2010 金蝶软件(中国)有限公司
P5
在Web服务器上安装IIS
1、控制面板——程序和功能,打开和关闭windows功能 2、按下图将红圈区域所规定的这些项及这些项下层选项都勾选上,进行对IIS及FTP的安装。(注意win7自带有 IIS7.0)

用友PLM企业研发创新管理平台 用户手册说明书

用友PLM企业研发创新管理平台 用户手册说明书

PLM企业研发创新管理平台引领中国企业PLM普及应用引领中国企业PLM普及应用CONTENTS目录用友PLM 企业研发创新管理平台综述用友PLM产品关键应用用友PLM企业研发创新管理平台帮助企业实现产品研发及设计过程中业务流程和产品数据的标准化管理,落地企业产品研发管理体系,改进产品研发业务流程,提高产品数据管理水平。

用友PLM帮助企业实现技术信息化,同时为企业以实施ERP为主的管理信息化奠定基础,用友PLM既是企业的产品研发管理平台,更是企业研发、工艺与生产的数据共享桥梁。

通过用友PLM企业研发创新管理平台项目化管理企业所有产品研发设计,实现产品开发过程的规范化,缩短产品开发周期;流程化管控产品研发阶段,控制产品开发过程,保证产品研发质量;借助统一PLM产品研发管理平台实现各部门各专业的协同化作业,同时数据化管理产品研发过程成果,提高产品改型设计效率,搭建企业产品研发知识、经验和规范库,实现产品设计方法的规范化,产品数据的标准化,以便控制产品成本;全面深度集成用友ERP,实现产品设计、工艺和制造业务和数据的一体化,为生产制造及时、准确提供所需产品数据 。

随着客户群体不断扩大及应用深度的拓展,用友企业研发创新管理平台已涵盖文档管理、物料管理、产品结构管理、变更管理等常规PDM功能,更延伸到项目管理、工艺规划、工艺文件设计、云端协同、CAD/EDA集成、ERP 集成等内容,成为国内PLM解决方案的领导者。

用友PLM企业研发创新管理平台核心思想是以产品研发项目业务流程为驱动,以物料和BOM等产品数据为主线的产品研发管理平台,用友PLM产品关键应用如下:提供友空间/微信号推送支持,提供客户端注册、绑定与解绑,任务的移动审批、图档、物料、变更申请、变更任务的查询及数据穿透功能,让你随时随地可以处理研发相关业务。

友空间/微信集成应用01引领中国企业PLM普及应用用友PLM企业研发创新管理平台用友PLM以产品研发管理体系为基石,帮助企业根据行业特点优化并固化企业产品开发流程,并将其定于到用友PLM中,成为企业项目管理的准则。

Siemens PLM Teamcenter iMAN 安装配置全过程指南

Siemens PLM Teamcenter iMAN 安装配置全过程指南

第二部分:安装Oracle 10gR2数据库软件并配置监听程序 在Oracle 10gR2数据库软件的安装盘点击setup.exe文件,不要选择创建启动数据库项:
mhtml:file://C:\Documents and Settings\Administrator\桌面\阳光网驿-企业信息化交... 2012-9-24
自动登录 登录
找回密码 注册
行业资讯
阳光论坛
软件商城
阳光币充值
网站建设
驿通软件
帮助
快捷导航
阳光商无城法| 阳找光到培训 | 软件商务 | 软件威客
用友技术 | 金蝶技术 | 管家婆区 | 速达交流
创业交流 | 求职招聘 | 社区团购 行软知道 | 远程接入 | 商超软件
会员签到 | 访问推广 实名认证 | 管理申请
选中使用Enterprise Manager配置数据库 选中所有帐户使用同一口令,这里我设置为aaa111:
mhtml:file://C:\Documents and Settings\Administrator\桌面\阳光网驿-企业信息化交... 2012-9-24
阳光网驿-企业信息化交流平台-Siemens PLM Teamcenter iMAN 安装配置全过程... Page 4 of 25
第一部分:基本环境准备
安装一个干净的Windows Server 2003+SP2,设置好主机名和静态IP地址。 将系统日期修改成2005年 修改ugnx4.lic许可证文件,即第一行修改成SERVER 主机名 ANY 27000的形式 新建一个用户infodba,密码为infodba,并加入管理员组,用用户infodba登陆系统进行后续的安装工作。
• 在地址中可能存在

PLM系统培训手册一.ppt

PLM系统培训手册一.ppt

在表格的标题栏上按小箭头,选择列,对显示列进行管理,移除、添加
查询·简单搜索
查询·高级搜索
查询·高级搜索
翻页
当前显示数量/搜索到的数量 显示所有
查询其他用户的主窗口
系统邮件
编辑邮件 查看邮件
复制、粘贴、剪切
右键菜 单
对于复制、粘贴,也可以直接 拖放
按住ctrl键,可选择多个目标 进行复制和剪切
选择更改对象
设计输入应用
1 产品信函 创建
输入信息
注意:必须发往部门及可选发放部 门为系统自动挂接
双击模板编辑保存
选中对象
提交流程
审签用户添加
审签结束后,对象为发布状态,同时 带发往部门同步到老PLM系统
更改
修订出新版本产品信函后,修改模板信息或者修改属性后,提交流程,其 他步骤同创建,提交流程相同。
查询
9、要学生做的事,教职员躬亲共做; 要学生 学的知 识,教 职员躬 亲共学 ;要学 生守的 规则, 教职员 躬亲共 守。20 21/7/1 92021/ 7/19Monday, July 19, 2021 10、阅读一切好书如同和过去最杰出 的人谈 话。202 1/7/19 2021/7/ 192021 /7/197 /19/202 1 3:58:32 PM 11、一个好的教师,是一个懂得心理 学和教 育学的 人。202 1/7/19 2021/7/ 192021 /7/19J ul-2119-Jul-21 12、要记住,你不仅是教课的教师, 也是学 生的教 育者, 生活的 导师和 道德的 引路人 。2021/ 7/1920 21/7/19 2021/7 /19Monday, July 19, 2021 13、He who seize the right moment, is the right man.谁把握机遇,谁就心想事成。2021/ 7/1920 21/7/1 92021/7 /19202 1/7/19 7/19/20 21 14、谁要是自己还没有发展培养和教 育好, 他就不 能发展 培养和 教育别 人。202 1年7月 19日星 期一20 21/7/1 92021/ 7/19202 1/7/19 15、一年之计,莫如树谷;十年之计 ,莫如 树木; 终身之 计,莫 如树人 。2021 年7月20 21/7/1 92021/ 7/19202 1/7/19 7/19/20 21 16、提出一个问题往往比解决一个更 重要。 因为解 决问题 也许仅 是一个 数学上 或实验 上的技 能而已 ,而提 出新的 问题, 却需要 有创造 性的想 像力, 而且标 志着科 学的真 正进步 。2021/ 7/1920 21/7/19 July 17、儿童是中心,教育的措施便围绕 他们而 组织起 来。202 1/7/19 2021/7/ 192021 /7/192 021/7/1 9

Perlight Solar PLM系列模块安装指南说明书

Perlight Solar PLM系列模块安装指南说明书

Perlight Solar PLM Series Module Installation ManualTable of Contents1. Introduction (3)2. Class Application (3)3. Applicable Modules (4)4. Warning and Notes (5)5. Permit (6)6. Climate Condition (6)7. Module Structure (6)8. Site Selection (7)9. Module Tilt Angle (7)10. Mounting and Notes ..........................................8-1011. Grounding (11)12. Module Wiring (12)13. Maintenance (13)14. Recycling (14)1. IntroductionPerlight Solar modules consist of a series of electrically interconnected crystalline silicon solar cells, which are permanently encapsulated between a tempered glass superstrate and substrate. The entire laminate is secured within an anodized aluminium frame for structural strength; ease of installation and to protect the cells from the most severe environmental conditions.Perlight Solar modules are a highly reliable, virtually maintenance-free direct current (DC) power source, designed to operate efficiently in sunlight. Perlight Solar modules are ideal for all applications, Residential, Commercial and Utility-Scale. Perlight Solar modules may also be used to power remote homes, recreational vehicles, water pumps, telecommunication systems and many other applications either with or without the use of storage batteries. Please read this manual carefully prior to handling and installation.Installation and maintenance of Perlight Solar modules may only be carried out by trained and qualified personnel.If you require further information, contact your supplier or local Perlight Service Centre.Please provide a copy of this manual to the owner and operator of the PV system for reference.Thank you for choosing Perlight Solar PV modules.2. Class ApplicationThe modules are qualified for application class A: Hazardous voltage (IEC 61730: higher than 50V DC; EN 61730: higher than 120V), hazardous power applications (higher than 240W) where general contact access is anticipated (Modules qualified for safety through EN IEC 61730-1 and -2 within this application class are considered to meet the requirements for Safety Class II).PV Modules with6” Mono-crystalline Cells:PV Modules with6” Poly-crystalline Cells:PV Modules with5” Mono-crystalline Cells:72 cells: PLM-***M-72 (*** = 245-385)72 cells: PLM-***P-72 (*** = 235-355)96 cells: PLM-***M-96 (***= 230-280) 72 cells: PLM-***MA-72 (*** = 245-385)72 cells: PLM-***PA-72 (*** = 235-355)96 cells: PLM-***MA-96 (***= 230-280) 72 cells: PLM-***MB-72 (*** = 245-385)72 cells: PLM-***PB-72 (*** = 235-355)96 cells: PLM-***MB-96 (***= 230-280) 66 cells: PLM-***M-66 (*** = 215-350)66 cells: PLM-***P-66 (*** = 225-325)72 cells: PLM-***M-72 (***= 160-210) 66 cells: PLM-***MA-66 (*** = 215-350)66 cells: PLM-***PA-66 (*** = 225-325)72 cells: PLM-***MA-72 (***= 160-210) 66 cells: PLM-***MB-66 (*** = 215-350)66 cells: PLM-***PB-66 (*** = 225-325)72 cells: PLM-***MB-72 (***= 160-210) 60 cells: PLM-***MA-60 (*** = 220-320)60 cells: PLM-***P-60 (*** = 195-295)66 cells: PLM-***M-66 (***= 145-190) 60 cells: PLM-***MA-60 (*** = 220-320)60 cells: PLM-***PA-60 (*** = 195-295)66 cells: PLM-***MA-66 (***= 145-190) 60 cells: PLM-***MB-60(*** = 220-320)60 cells: PLM-***PB-60 (*** = 195-295)66 cells: PLM-***MB-66 (***= 145-190) 54 cells: PLM-***M-54 (*** = 185-285)54 cells: PLM-***P-54 (*** = 180-265)60 cells: PLM-***M-60 (***= 130-175) 54 cells: PLM-***MA-54 (*** = 185-285)54 cells: PLM-***PA-54 (*** = 180-265)60 cells: PLM-***MA-60 (***= 130-175) 54 cells: PLM-***MB-54 (*** = 185-285)54 cells: PLM-***PB-54 (*** = 180-265)60 cells: PLM-***MB-60 (***= 130-175) 48 cells: PLM-***M-48 (*** = 155-255)48 cells: PLM-***P-48 (*** = 165-235)54 cells: PLM-***M-54 (***= 120-155) 48 cells: PLM-***MA-48 (*** = 155-255)48 cells: PLM-***PA-48 (*** = 165-235)54 cells: PLM-***MA-54 (***= 120-155) 48 cells: PLM-***MB-48 (*** = 155-255)48 cells: PLM-***PB-48 (*** = 165-235)54 cells: PLM-***MB-54 (***= 120-155) 36 cells: PLM-***M-36 (*** = 125-190)36 cells: PLM-***P-36 (*** = 125-175)48 cells: PLM-***M-48 (***= 105-140) 36 cells: PLM-***MA-36 (*** = 125-190)36 cells: PLM-***PA-36 (*** = 125-175)48 cells: PLM-***MA-48 (***= 105-140) 36 cells: PLM-***MB-36 (*** = 125-190)36 cells: PLM-***PB-36 (*** = 125-175)48 cells: PLM-***MB-48 (***= 105-140) 24 cells: PLM-***M-24 (*** = 80-125)24 cells: PLM-***P-24 (*** = 80-115)36 cells: PLM-***M-36 (*** = 80-105) 24 cells: PLM-***MA-24 (*** = 80-125)24 cells: PLM-***PA-24 (*** = 80-115)36 cells: PLM-***MA-36 (*** = 80-105) 24 cells: PLM-***MB-24 (*** = 80-125)24 cells: PLM-***PB-24 (*** = 80-115)36 cells: PLM-***MB-36 (*** = 80-105)24 cells: PLM-***M-24 (*** = 55-70)24 cells: PLM-***MA-24 (*** = 55-70)Mini Panels withSliced 6” Mono-crystalline Cells:Mini Panels withSliced 5” Mono-crystalline Cells:Mini Panels withSliced 6” Poly-crystalline Cells:36 cells: PLM-***M-36 (*** = 5, 10, 20, 30, 40, 50, 60, 70, 80, 100, 120)36 cells: PLM-***M-36 (*** = 5,10, 50)36 cells: PLM-***P-36 (*** = 5, 10, 20, 30,40, 50, 60, 70, 80, 100, 120)36 cells: PLM-***MA-36 (*** = 5, 10, 20, 30, 40, 50, 60, 70, 80, 100, 120)36 cells: PLM-***MA-36 (*** = 5,10, 50)36 cells: PLM-***PA-36 (*** = 5, 10, 20, 30,40, 50, 60, 70, 80, 100, 120)3. Applicable ModulesThis installation manual is applicable to the following modules:For the modules listed above *** represents module Wp in increments of 5W of figures shown.For Mini Panels listed above *** represents Wp stated.4. Warning and NotesPerlight Solar modules generate electricity when exposed to light. An arrayof modules can cause lethal shock and burn hazards. Only authorized andtrained personnel should have access to the PV modules. To reduce the riskof electrical shock or burns, modules may be covered with an opaque materialduring installation. Do not touch live terminals with bare hands. Use insulatedtools for electrical connections.Each Perlight Solar module has a pair of male and female waterproof connectors. For a series electrical connection, connect positive (+) connector of first solar module to negative (-) connector of the following module.Do not short the positive and the negative. Do not disconnect under load. Ensure each connection is sound with no gap between the insulators. Poor connections may cause arcing and pose a fire and/or an electrical shock hazard.Artificially concentrated sunlight shall not be directed on the Perlight Solar module. The electrical characteristics are the indicated value of Pmax under standard test conditions (Irradiance of 1000W/m², AM 1.5 spectrum, and cell temperature of 25°C).Under normal conditions, a solar PV module is likely to experience conditions that produce more current and/or voltage than reported at standard test conditions. Accordingly the value of Isc and Voc marked on this module should be multiplied by a factor of 1.25 when determining component voltage ratings, conductor current ratings, fuse sizes, and sizesof controls connected to the Perlight Solar PV module output. Refer to local and national Electrical Code for any additional multiplying factors, which may also be applicable.Handle with careUnpack and handle the PV modules with care. For safety always avoid installing PV modules during wet and windy conditions or during electrical storms.• Do not place heavy objects on to the PV modules.• Do not step or walk on the module, although Perlight Solar modules are rugged, flexing caused by bodyweight on the module face can create micro-cracks in the solar cells, which may not be visible but will effect cell performance as the module ages. Take care not to impact the module during installation, module glass can be broken (and the module will no longer work properly) if it is dropped or hit by tools or other objects.• Take care not to allow the front glass or backsheet of the module come into contact with hard or sharp surfaces such as scaffold during the installation process to avoid scratching or damaging the PV module.• Do not scratch the PV module backsheet.• Do not drill or cut the PV module frame.• Do not apply paint or glue to the PV module.5. PermitBefore installing your system, contact local authorities to determine the necessary permit, installation and inspection requirements.6. Climate ConditionsInstall the Perlight Solar PV modules in the following conditions:• Ambient temperature: -20°C to +40°C.• Operating temperature: -40°C to +85°C.• Storage temperature: -40°C to +40°C• Humidity: below 85RH%• Wind pressure: below 50.12lb / ft² (2400Pa)• Corrosion resistant: Except for corrosive salt areas and sulphurous areas.7. Module StructureFig.1: Module Structure8. Site SelectionIn most applications, Perlight Solar modules should be installed in a location where theywill receive maximum sunlight throughout the year. In the Northern Hemisphere, the module should typically face south, and in the Southern Hemisphere, the modules should typically face north. Modules facing 30 degrees away from true South (or North) will lose approximately 10 to 15 per cent of their power output. If the module faces 60 degrees away from true South (or North), the power loss will be 20 to 30 percent.When choosing a site, avoid trees, buildings or obstructions, which could cast shadows on the solar photovoltaic modules especially during the winter months when the arc of the sun is lowest over the horizon. Shading causes loss of output, even though the factory fitted bypass diodes of the Perlight Solar module will minimize any such loss.Do not install the Perlight Solar module near naked flame or flammable materials. Do not install the Perlight Solar module in a location where it would be immersed in water or continually exposed to water from a sprinkler or fountain etc.9. Module Tilt AnglePerlight Solar modules connected in series should be installed at same orientation and angle. Different orientation or angle may cause loss of output power due to difference in amount of sunlight exposed to the module.Perlight Solar modules produce the most power when they are pointed directly at the sun. For installations where the Perlight Solar modules are attached to a permanent structure, the modules should be tilted for optimum winter performance. As a rule, if the system power production is adequate in winter, it will be satisfactory during the rest of the year. The module tilt angle is measured between the solar modules and the ground (Figure 2). Optimal tilting of Perlight Solar module is almost the same as the latitude of installation location.Fig.2: Installation angle Degrees ofLatitude Tilt Angle0⁰ ~ 15⁰15⁰15⁰ ~ 25⁰Equal to Latitude 25⁰ ~ 30⁰Latitude + 5⁰30⁰ ~ 35⁰Latitude + 10⁰35⁰ ~ 40⁰Latitude + 15⁰40⁰ +Latitude + 20⁰10. Mounting and NotesThe PV module frame is made of anodized aluminium, and therefore corrosion can occur if the module is subjected to a salt water environment with contact to a rack of another typeof metal (Electrolysis Corrosion). If required, PVC, EPDM or stainless steel washers can be placed between the PV module frame and support structure to prevent this type of corrosion. Module support structures that are to be used to support Perlight Solar modules at the correct tilt angles should be wind and snow load rated for use by the appropriate local and civil codes prior to installation.Perlight Solar modules can be mounted using the following methods:• Direct fixing to mounting structure• Suitable module clamps as part of solar mounting system• Insertion systems• Roof integrated systemsDirect Fixing to Mounting Structure2400Pa Wind Load 2400Pa Snow Load 5400Pa Wind Load 3800Pa Snow LoadUse Four Mounting Holes Use Eight Mounting HolesDirect Fixing to Mounting StructureThe frame of each module has 8 mounting holes(14mm*9mm), which can be used to secure themodules to a supporting structure. The module framemust be attached to a supporting structure usingcorrosion-proof M8 stainless steel nuts and bolts withspring washers and flat washers in at least four pointssymmetrical on the PV module. Applied torque isapprox. 8 Newton-meters.Solar Mounting Systems2400Pa Wind Load 2400Pa Snow Load 5400Pa Wind Load 3800Pa Snow LoadFig.:3 Use Four Clamps Fig.: 4 Use Four Clamps on Short Side and TwoClamps on Long SideFig.: 5 Use Four Clamps Fig.:6 Use Six ClampsModule mounting clamps must not come into contact with the front glass and must not deform the frame. Module clamps should not cause shadowing effects. It is not permitted to modify the module frame under any circumstances. Recommended distance between two modules is 5mm considering linear thermal expansion of the module frames.Clearance between the module frame and mounting surface may be required to prevent the junction box from touching the surface, and to circulate cooling air around the back of the module.Insertion Mounting Systems2400Pa Wind Load 2400Pa Snow Load 5400Pa Wind Load 3800Pa Snow LoadFig.: 7 Insertion System Short Side Fig.: 8 Insertion System Short Side and Two Clampson Long Side.Insertion Systems must not cause shadowing effects.It is not permitted to modify the module frame underany circumstances. Recommended distance betweentwo modules is 5mm considering linear thermalexpansion of the module frames.Clearance between the module frame and mountingsurface may be required to prevent the junction boxfrom touching the surface, and to circulate cooling airaround the back of the module.Fig.: 9 Insertion System Long SideMounting design may have an impact on fire resistance. If the modules are to be installed on the roof or wall of a building, using an integrated mounting system, the fire resistance of roof covering or wall should be rated for the application and certified for use to local and national standards. Here the stand-off method or the rack method is recommended. The modules are supported parallel to the surface of the building wall or roof. Clearance between the module frames and surface of the wall or roof is required to prevent wiring damage and to allow air to circulate behind the module. The recommended stand-off height is 115mm. Any slope less than 5in/ft (127mm/305mm) is required to maintain a fire class rating. Do not mount Perlight Solar module in such way that the drain holes of the module are intended to block up. Roof-integrated (in-roof) systems must comply with local and national regulations, including fire test certification where necessary.11. GroundingAll module frames and mounting racks must be properly grounded in accordance with local and national electrical regulations. Proper grounding is achieved by connecting the module frame(s) and structural members continuously one to another using a suitable grounding conductor. The grounding conductor or strap may be copper, copper alloy, or other material acceptable for use as an electrical conductor as per local and national guidelines. The grounding conductor must then make a connection to earth using a suitable earth ground electrode.Attach a separate conductor to one of the marked 4mm diameter grounding holes on the module frame with a bolt and nut that incorporates an external tooth washer. This is to ensure positive electrical contact with the frame.The rack must also be grounded unless they are mechanically connected by nuts and bolts to the grounded Perlight Solar modules. The array frame shall be grounded in accordance with local and national guidelines. Standard1Bolt M42Spring washer M4 x 1.13Star washer M4 x 0.84Ground crimp M4 stud5Module Frame6Star washer M4 x 0.87Nut M4 Fig.10: Grounding crimp and washer sizes12. Module WiringEach solar module is wired with three separate series cell strings.Bypass DiodesBypass diodes are wired in parallel with the series cell strings to prevent hot spot heating caused by individual cell reverse bias that occurs when a module is partially shaded. Output CablesEach module has two standard 90°C rated, water-proof, UV resistant output cables each terminated with plug & play connectors. This cable is suitable for applications where wiring is exposed to the direct rays of the Sun.Field connectionsConnecting cables should be a minimum of 12 AWG copper cables, which are UV resistant and insulated for a minimum of 90°C. All wiring and electrical connections must comply with local and national Electrical Code.Blocking DiodesIn a system utilizing a battery, blocking diodes are typically placed between the batteryand the solar module output to prevent battery discharge at night. Diodes that are used as blocking diodes must: Have a Rated Average Forward Current [IF(AV)] above maximum system current at highest module operating temperature. Have a Rated Repetitive Peak Reverse Voltage [VRRM] above maximum system voltage at lowest module operating temperature.13. MaintenanceCleaningUnder most weather conditions, normal rainfall is sufficient to keep the Perlight Solar module glass surface clean. If dirt build-up becomes excessive, clean the glass only with a soft cloth using mild detergent and water. USE CAUTION WHEN CLEANING THE BACK SURFACEOF THE MODULE TO AVOID PENETRATING THE SUBSTRATE MATERIALS. Solar Modules that are mounted flat (0° tilt angle) should be cleaned more often, as they will not ‘’self clean’’ as effectively as modules mounted at a 15° tilt or greater. Perlight recommend cleaning the modules during the early morning or evening, when the panels will be operating at a lower temperature and producing little energy.• Do not lean or stand on the modules during cleaning.• Do not use high pressure water jets to clean the solar modules.Annual ChecksOnce a year, check the tightness of terminal screws and the general condition of the wiring. Also, check to ensure the mounting hardware is tight and secure. Loose connections will result in damage to the array.Changed Perlight Solar modules must be of the same kind and type. Do not touch live parts of cables and connectors. Use appropriate safety equipment when working (insulated tools, insulating gloves, etc.).Only trained personnel may carry-out repair work to the PV modules andsystem components.Cover the front surface of the solar module with an opaque or other materialwhen working on the modules. Solar modules generate high voltage whenexposed to sunlight.14. RecyclingPerlight work to avoid unnecessary waste, keeping module packaging to a minimum, while maintaining the protection of the modules during transport.Please recycle the cardboard and paper packaging in accordance with local guidelines and regulations.End of Life Disposal and RecyclingPerlight solar modules are designed to produce electricity for a minimum of 25 years, however the panels may continue to offer useful energy for years to come after this point. Once the panels reach the end of their useful life, they should be recycled in accordance with local guidelines and regulations.Within the European Union, solar modules are subject to Waste Electrical and Electronic Equipment (WEEE) regulations. The WEEE symbol is displayed on every module nameplate label at the rear of the panel. This means that this product shall not be treated as household waste and must be disposed ofat an appropriate collection point.Fig.11: WEEE SymbolPerlight Solar Co.,Ltd.Address:Oufeng Road, Muyu, Zeguo Town,Wenling City, Zhejiang Province,317521, ChinaTel: 0086-576-86477920www.perli ********************。

PLM2018操作手册-01-基础设置

PLM2018操作手册-01-基础设置

PLM设置主要包括用户管理、角色管理、日志管理、参数设置、流程定义、流程实例化、编码管理、编码申请管理、数据类型配置、ERP集成配置、ERP属性映射、文档浏览器设置、导航分类定义、图标分类定义、密码策略、二维码设置这些功能。

以下逐一操作进行说明。

用户管理用户管理主要对PLM登录操作人员档案进行的管理,其中包含企业组织架构、用户信息、文档信息、产品信息、物料信息、任务信息、电子签章等。

1、企业组织工作组添加1.1、点击添加工作组1.2、填写工作组名称、工作组编码2、选择现有工作组,可以对工作组进行修改、删除、添加用户操作2.1、修改工作组2.2、删除工作组3、添加用户3.1点击添加用户3.2、填写姓名、代号、对个人工作区位置进行编辑等4、选中人员信息,可对其进行设置密码、修改用户属性、设置用户角色、移动用户、禁用用户、删除用户、锁定用户等操作,也可以对该用户相关的文档信息、产品信息、物料信息进行excel导出,电子签章进行生成、修改、删除和下载.4.1、选中人员,点击设置密码,填写新密码,确认密码4.2、点击修改用户属性,对用户姓名等进行修改4.3、点击设置用户角色,从角色列表选择对应角色到角色设置,点击确定5、企业组织中选中对应人员,选择右边列表中的电子签章,可对电子签章进行设置5.1、点击添加,添加DWG/PDF签章5.2、同上操作选择下方生成印章5.2.1、首次设置印章时需要装载印章管理控件。

5.2.2、点击不能装载控件处,右键,点击属性5.2.3、复制中间链接到ie浏览器中进行打开,并允许阻止的内容5.2.4、控件加载完成如图提示,点击确定5.2.5 返回plm中重新打开生成印章,对印章名称、印章用户、印章口令进行编辑。

印章密码最短为6位。

5.2.6、点击浏览,选择已设置好的印章图片,选中好之后点击创建印章角色管理角色管理包含非项目角色和项目角色两类,非项目角色主要对与项目管理的角色权限进行控制;项目管理主要对项目管理相关角色的权限进行控制。

鼎捷PLM System安装手册(简体版)

鼎捷PLM System安装手册(简体版)

鼎捷 PLM System安装手册中文简体适用最低版本:1.0.352015年6月目录中文简体 (I)1 安装光盘目录说明 (1)2 系统安装和集成环境 (1)2.1 支持操作系统与环境 (1)2.2 服务端配置参考 (1)2.3 集成环境 (2)3 数据库系统安装 (1)3.1 数据库版本 (1)3.2 数据库安装 (1)3.3 数据库监听配置 (10)3.4 数据库配置调整 (13)3.5 数据库初始化导入 (14)4 产品安装 (1)4.1 Windows环境 (1)4.1.1服务器安装 (1)4.1.2客户端安装 (11)5 JDK配置 (1)6 软件升级 (1)7 鼎捷 PLM SYSTEM配置文件 (1)7.1 dsconn.xml (1)7.2 sql-map-config.xml配置 (2)7.3 server.xml配置 (2)7.4 dssserver.xml分布式部署配置 (3)7.5 服务端client.xml配置 (3)7.6 客户端client.xml配置 (4)7.7 多语言 (4)8 集成配置文件 (5)9 Q&A (6)1安装光盘目录说明安装光盘的根目录有六个文件夹:CADI,Client,Manual,ReleaseNote,Server,Update,简单介绍如下:CADI: CAD的安装和配置文件;Client: 客户端的安装文件,主要包含以下内容:Report Tools: 报表工具;ClientSetup.exe: PLM客户端安装程序;DMSetup.exe: 数据维护工具安装程序;LMSetup.exe: 许可证监视器安装程序;NRMSetup.exe: 编码管理器安装程序;OMSetup.exe: 建模器安装程序;CFDMSetup.exe: 分类数据维护工具安装程序;CFOMSetup.exe: 分类建模器安装程序;Manual: 用户使用手册;ReleaseNote: 发布声明;Server: 服务端的安装文件;Update: 服务端的升级文件;2系统安装和集成环境2.1支持操作系统与环境Server OS Windows Server 2003(32bit) Windows Server 2003(64bit) Windows Server 2008(32bit) Windows Server 2008(64bit) Windows Server 2008R2 Windows Server 2012DB Oracle Database Express Edition 11g Release 2 for Windows(32bit)Oracle Database Express Edition 11g Release 2 for Windows(64bit)Oralce 12CClient OS Windows 7 (32bit)Windows 7 (64bit)Windows 8 (32bit)Windows 8 (64bit)Windows 8.1 (64bit)Windows XP (32bit)Windows XP Professional (64bit)TomCat 6.0.2JDK 1.62.2服务端配置参考小规模-在线用户15人以下,或客户端安装30人以下CPU Intel Xeon 四核/八核RAM 8GB/16GBHDD 250G(与需要存储的图文档档总量有关)Network 以太网接口,1000MbpsOS MS Windows Server 2003(含)以上中等规模-在线用户16~50人以下,或客户端安装30~150人以下CPU Intel Xeon八核/十六核RAM 16GB/32GBHDD 500G(与需要存储的图文档档总量有关)Network 以太网接口,1000MbpsOS MS Windows Server 2003(含)以上*建议将应用服务器和存储服务器分开部署以提高性能大规模-在线用户50-100人以上,或客户端安装150人以上CPU Intel Xeon 十六核/三十二核RAM 32GB/64GBHDD 1T(与需要存储的图文档档总量有关)Network 以太网接口,1000MbpsOS MS Windows Server 2003(含)以上*建议将应用服务器和存储服务器分开部署以提高性能2.3集成环境名称版本TipTopGp PLM1.0.37之前的版本支持GP5.00.23以上、GP5.25.09以上和GP5.30.08以上的小版本(其余不支持的小版均需要做ERP程序版更后才能支持)PLM1.0.37版本支持5.30.19及以后(其余不知援的小版均需要做ERP程序版更后才能支持)WorkFlow 4.0易飞8、9E10 2.0、3.0.0SmartERP 9.2.1名称版本CROSS 1.1名称版本AutoCAD 2008-2016Inventor 2010-2014Unigraphics NX 4.0-9.0Pro/ENGINEER 3.0、4.0、5.0、Creo1.0、Creo2.0SolidEdge ST3、ST4、ST5SolidWorks 2006-2015PADS(Logic、Layout、9.3、9.5DxDesigner)Altium Designer Summer 09、Winter 09 Cadence 16.3、16.53数据库系统安装3.1数据库版本数据库最低版本要求:Oracle Database 11g Enterprise Edition Release 11.2.0.1.0。

PLM安装配置手册

PLM安装配置手册

PLM安装配置手册严格按照以下安装顺序1:设置IIS控制面板—〉添加删除程序---〉添加删除windows组件---〉双击internet信息服务勾选文件传输协议,点击确定windows2003:选取iis6.0windows Xp:选取IIS5.1点击下一步选取iis5.1xp里面的文件,注意iis5.1xp要放在英文目录下面2:安装dotnetfx3.5sp1程序在PLM程序包中包含K3_WISE_V12.2_PLM\ OS_Default \dotnetfx3.5sp13:安装MSChartK3_WISE_V12.2_PLM \OS_Default\MSCHART\ MSChart.exe3:数据库安装_sql2005\Servers(1)其中有个要填用户名和密码的页面不选域模式就好了,就不用填用户名和密码了。

(2)其中有一个页面一定要选择访问数据库模式为混合验证模式并设置默认用户SA的密码(一定要设置密码)。

记住自己设置的sa的密码(3)安装好后再安装sp3升级包(4)如果是SQL Server2000 则安装SP4版本以上都安装完成后,打开数据库,用电脑名称连接服务器右键打开数据库—〉新建---〉填写plm或pim点击确定建立好这两个数据库4:安装plm安装时不用执行环境检测,直接安装在下面这个画面选全部安装在下面生成PLM web 站点的画面中,填上登录plm时要使用到站点名称,默认是plm Plm物理路径系统会自动找到程序路径无需修改建立站点的名称上面必须是xsn_template,系统会默认无需修改表单物理路径的文件夹应事先在服务器上设置,在“表单物理路径”中选到建好的表单文件夹,ftp文件夹也要在相应的服务器上建好,如果ftp和应用程序在一台服务器上,在这里可以直接点击高级来设置默认ftp站点全部设置好后在站点设置界面中点击设置,提示成功点击关闭按钮,进入数据库初始化界面初始化plm帐套密码为安装数据库时设置的sa的密码,注意plm和pim都要连接5:设置net.asp用户把ASPNET及NETWORK SERVICE用户添加到Administrators角色组中在用户中查看有没有net.asp用户,没有就添加,添加后去组里面把他加入到administrator 组中设置aspnet及NETWORK SERVICE访问表单、PLM站点和FTP站点的权限可以在在表单、PLMweb站点文件夹、ftp物理存储路径文件夹上右键点属性,添加aspnet及NETWORK SERVICE用户然后设置他的权限为完全控制也可以在IIS站点上点击右键选择权限来添加aspnet及NETWORK SERVICE用户然后设置他的权限为完全控制6:检查web扩展服务里面的是否存在是否是允许的如果不存在用下图中的命令起起来,之所以出现上面这样的问题有两个原因:1:没有安装dotnetfx3.5sp1,2:dotnetfx3.5sp1先于IIS安装,如果成功安装了dotnetfx3.5sp1(请在添加安装程序里确认),且是在IIS之后安装的这个步骤应该就不用检查了,也不会有问题X64 位系统需要进行的环境配置程序在编译的时候默认是Any CPU,即编译的程序可以在X86、X64 系统平台上运行。

用友PLM安装使用说明书

用友PLM安装使用说明书

用友PLM安装使用说明配置篇:安装用友PLM前,请先阅读以下内容:本安装程序支持的环境:操作系统:支持Windows 2000,Windows2003服务版,必须安装有IIS(文件服务器必须安装)。

数据库服务:支持SQL SERVER2000 Sp3;SQL SERVER 2005(开发版要注意1433端口是否打开)安装注意事项:A:如果SQL SERVER 为2005,请手动创建、还原数据库,Ftp也需手动创建,配置。

然后在配置界面中可使用保存配置信息,进行数据库信息设置和打包程序。

(具体可参考“配置安装说明4 保存配置信息”部分)B:数据库安装登陆请使用混合模式,不能只使用Windows身份验证。

C:如果配置工具中读取不到sqlserver信息,需启动SQL Agent服务(打开企业管理器服务端,下拉选择Sql Agent,启动)。

D:还原数据库文件不要放到桌面上,放到具体盘符下,否则数据库用配置工具还原不了。

安装步骤:1.运行installer.exe.2.最好选用典型安装:3.可修改默认安装位置:4.其他选用默认安装设置即可.5.加密狗安装程序可以选择安装,也可以取消.6.该类似文件选择否:7.完成安装时,建议选择重新启动系统,以确保相关功能可成功操作。

配置安装说明:1.安装完成后,从开始菜单\程序\ufidaplm\配置工具,打开配置工具,进行数据库创建、设置和ftp设置:2.执行配置工具,打开下面的配置界面:先输入数据库用户名和数据库密码,再选择数据库服务器名称。

(这是此配置界面的必要操作)先创建数据库:在数据库名称中填写一个新的数据库名称。

点击,提示创建成功:3.还原数据库:点击,打开下面的界面,选择数据库文件(请确定该数据库备份文件在所使用的SQLSERVER所在机器上):点击“打开”按钮,系统自动还原,数据库成功还原:4.保存配置信息:本功能实现写入发布使用数据库信息及程序打包功能。

PLM系统环境部署

PLM系统环境部署

PLM系统环境部署1.oracle软件安装创建数据库实例1). 在oracle程序包中运行下图中“setup”文件。

2).去掉红色框内的“√”,然后单击“下一步”。

3). 选择单击下图中的“是”。

4). 选择下图“创建和配置数据库”,然后选择单击“下一步”。

5).选择数据库安装类型。

然后选择单击“下一步”。

6).选择创建数据库事例的类型。

然后选择单击“下一步”。

7).选择下图的“高级安装”,然后选择单击“下一步”。

8).选择安装语言,一般为默认即可。

然后选择单击“下一步”。

9).选择数据库类型,然后选择单击“下一步”。

10).选择数据库安装路径。

然后选择单击“下一步”。

11).选择数据库用途,选择“一般用途事务处理”即可。

然后选择单击“下一步”。

12).输入创建数据库的“全局数据库名”,然后选择点击“下一步”。

13).分配数据库内存比例,一般默认即可。

14).然后选择数据库字符集,一般选择“ZHS16GBK”,然后选择点击“下一步”。

15).选择点击“下一步”16).选择“文件系统”,然后选择单击“下一步”。

17).选择“不启用自动备份”,然后选择点击“下一步”。

18).输入数据库用户密码。

然后选择单击“下一步”。

19). 查看数据库安装信息是否正确,如果正确,请选择“完成”。

20). 安装和配置数据库。

直到安装成功。

2.安装和配置ODP 11g。

1). 运行ODP 11g文件包中的“setup”程序文件。

然后选择点击“下一步”。

2). 选择红框标记的项,然后选择单击“下一步”。

3). 选择ODP11g安装目录。

然后选择单击“下一步”。

4). 按照这下图标记依次处理,直到安装结束。

5).将odp安装目录下标记的两文件拷贝到上一层目录。

然后将tnsnames文件按下图进行配置。

3.PL/SQL安装及数据库用户创建。

1).安装PL/SQL软件。

2).PL/SQL软件汉化。

3).PL/SQL软件注册。

PLM使用手册

PLM使用手册

PLM使用手册(版本1.0 编制:房臣)目录1前言 (3)2系统准备 (3)3 PLM安装以及注册 (3)3.1 中望CAD的安装以及配置: (4)1)安装中望CAD系统 (4)2)激活中望CAD系统 (4)3)配置中望CAD模板 (4)4)常见问题 (5)3.2 PLM与中望CAD的接口的安装 (5)1)检查安装环境 (5)2)安装接口软件 (5)3)常见问题 (6)3。

3接口软件的配置 (6)1)配置启动方式 (6)2)配置使用环境 (7)3)登录PLM系统 (8)4)常见问题 (9)3。

4 PLM网页系统的安装 (10)1)下载并安装控件 (10)2)登录网页系统 (11)3)常见问题 (11)3。

5 PLM系统使用要求 (11)4 PLM接口软件的使用 (12)4.1 图纸明细表 (12)1)填写要求 (12)2)填写步骤 (12)3)常见问题 (14)4.2 图纸上传 (14)1)上传规则 (14)2)操作步骤 (14)3)常见问题 (15)5 PLM系统的使用 (17)5.1 物料申请 (17)1)新建申请单 (17)2)填写申请单 (18)3)启动流程 (19)4)审核 (19)5.2 图纸下载 (19)1)下载方法 (19)2)常见问题 (19)5。

3 生成BOM (20)1)操作步骤 (20)2)常见问题 (22)5.4 图纸的修改 (23)1)操作步骤 (23)6 工艺模块的使用 (23)6。

1 物料添加 (24)6。

2 跳层的设置 (25)6.3 BOM导入ERP (26)6.4 P-BOM更改 (27)7生产BOM的输出 (27)8补充说明 (27)8。

1 项目总图 (27)8.2 其他说明 (29)1前言PLM系统是伴随着生产信息化而产生的一种信息平台。

与传统模式相比,该系统的主要优点是信息传递准确、信息记录完整,实现信息在多部门之间的无误流转,有利于综合控制效率、质量、成本。

PLM之基础配置操作指引

PLM之基础配置操作指引

6
一、 PLM基础配置操作指引(角色管理的配置)
操作说明: 1、角色分为系统角色、 普通角色、项目角色及 任务角色四种,系统角 色是系统内置的,无法 新建。普通、项目、任 务角色都可以根据公司 业务来详细设置。普通 角色是设定属于这个角 色的人员可以使用哪些 模块,项目角色是针对 某个项目的权限,任务 角色是针对某个任务中 的权限
15
一、 PLM基础配置操作指引(编码规则的设定)
操作说明: 1、主菜单中选择“配 置”—“编码规则” 2、在右边窗口选择新 建 3、此例以“WD-YY001(文档+部门+流水 号)为例
16
一、 PLM基础配置操作指引(编码规则的设定)
操作说明: 1、在弹出的编码规则 信息页面中先填写基本 属性内容 2、基本属性主要有五 个选项,填写编码规则 编号及名称;起始序列 号默认一般是1;最大 序列号默认为0,0表 示不受限制,编码规则 类型选择右边下拉菜单 选择相应的类型,此例 选择“项目” 3、全部完成后选择确 定
17
一、 PLM基础配置操作指引(编码规则的设定)
操作说明: 1、基本属性定义完后, 选择旁边的项定义 2、填写项名称,可随 便填 3、类型在右边下拉菜 单中选择相应的类型, (按照此编码规来选 择),此例为固定字符 串,因为所有文档类的 编码都以WD来命名 4、内容在这里就输入 WD 5、连接符根据我们的 实例是“-” 6、完成后点击确定
41
一、 PLM基础配置操作指引( 项目模板库的设置)
操作说明: 1、主菜单中定位到系 统—项目模板库 2、在右边项目模板库 页面中模板文件夹,鼠 标右键新建文件夹 3、在弹出的新页面中 填写模板文件夹编码及 模板文件夹名称 4填写完后点击确定
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

PLM安装配置手册
严格按照以下安装顺序
1:设置IIS
控制面板—〉添加删除程序---〉添加删除windows组件---〉双击internet信息服务勾选文件传输协议,点击确定
windows2003:
选取iis6.0
windows Xp:选取IIS5.1
点击下一步
选取iis5.1xp里面的文件,注意iis5.1xp要放在英文目录下面
2:安装dotnetfx3.5sp1程序在PLM程序包中包含
K3_WISE_V12.2_PLM\ OS_Default \dotnetfx3.5sp1
3:安装MSChart
K3_WISE_V12.2_PLM \OS_Default\MSCHART\ MSChart.exe
3:数据库安装_sql2005\Servers
(1)其中有个要填用户名和密码的页面不选域模式就好了,就不用填用户名和密码了。

(2)其中有一个页面一定要选择访问数据库模式为混合验证模式
并设置默认用户SA的密码(一定要设置密码)。

记住自己设置的sa的密码(3)安装好后再安装sp3升级包
(4)如果是SQL Server2000 则安装SP4版本
以上都安装完成后,打开数据库,用电脑名称连接服务器
右键打开数据库—〉新建---〉填写plm或pim点击确定建立好这两个数据库
4:安装plm
安装时不用执行环境检测,直接安装
在下面这个画面选全部安装
在下面生成PLM web 站点的画面中,填上登录plm时要使用到站点名称,默认是plm Plm物理路径系统会自动找到程序路径无需修改
建立站点的名称上面必须是xsn_template,系统会默认无需修改
表单物理路径的文件夹应事先在服务器上设置,在“表单物理路径”中选到建好的表单文件夹,ftp文件夹也要在相应的服务器上建好,如果ftp和应用程序在一台服务器上,在这里可以直接点击高级来设置默认ftp站点
全部设置好后在站点设置界面中点击设置,提示成功点击关闭按钮,进入数据库初始化界面
初始化plm帐套
密码为安装数据库时设置的sa的密码,注意plm和pim都要连接
5:设置net.asp用户
把ASPNET及NETWORK SERVICE用户添加到Administrators角色组中
在用户中查看有没有net.asp用户,没有就添加,添加后去组里面把他加入到administrator 组中
设置aspnet及NETWORK SERVICE访问表单、PLM站点和FTP站点的权限
可以在在表单、PLMweb站点文件夹、ftp物理存储路径文件夹上右键点属性,添加aspnet及NETWORK SERVICE用户然后设置他的权限为完全控制
也可以在IIS站点上点击右键选择权限来添加aspnet及NETWORK SERVICE用户然后设置他的权限为完全控制
6:检查web扩展服务里面的是否存在是否是允许的
如果不存在用下图中的命令起起来,
之所以出现上面这样的问题有两个原因:1:没有安装dotnetfx3.5sp1,2:dotnetfx3.5sp1先于IIS安装,如果成功安装了dotnetfx3.5sp1(请在添加安装程序里确认),且是在IIS之后安装的这个步骤应该就不用检查了,也不会有问题
X64 位系统需要进行的环境配置
程序在编译的时候默认是Any CPU,即编译的程序可以在X86、X64 系统平台上运行。


希望我们的 程序运行在X64系统上,我们所要做的仅仅是部署IIS,修改配置。

若想程序运行于IIS32 位模式下,即运行在.net framwork32位下进行如下配置:修改IIS 配置
1) 在运行中录入:cscript %systemdrive%\inetpub\adminscripts\adsutil.vbs set
w3svc/appPools/enable32bitapponwin64 1
这个步骤是修改IIS 配置,允许32位程序运行
2)在运行中录入:C:\WINDOWS\\Framework\v2.0.50727\aspnet_regiis i
为IIS 注册32。

注册后在IIS 的web 扩展里显示的是2.0.*32bit。

此注册请注意系统安装的目录(多系统情况下可能不一定在C 盘)
3)安装完.NET Framework3.5sp1后执行InstallOn64.bat程序
4 )Web扩展里允许2.0.*32bit运行。

运行的是w3wp32.exe进程。

注意在安装PLM系统后,要设置IIS 的权限(匿名用户和集成WINDOWS登陆)
7:检查表单,PLM站点及FTP站点的设置,在站点上点击右键---》属性
表单和FTP都要勾选写入权限
PLM和表单站点都要勾选匿名访问和集成windows身份验证
PLM和表单站点版本都要是下图所选值
8:设置PLMLicenseServer.exe.config
在下图安装路径config路径下找到Config.exe打开选择license配置文件,填上服务器IP或名称,填上数据库用户名和密码选择PLM数据库,点击高级在FTP编码处填上001默认编码,点击确定。

点击生成,即会在改路径下生成一个PLMLicenseServer.exe.config文件,把这个文件拷贝到安装路径下的Tools\PLMLicenseServer路径下覆盖原文件即可
在下config路径下找到Config.exe打开选择PIM/PLM配置文件,填上服务器IP或名称,填上数据库用户名和密码选择对应数据库,点击高级在FTP编码处填上001默认编码,点击确定。

点击生成,即会在改路径下生成一个web.config和fig文件,把这两个文件拷贝到安装路径下的K3PLM\WEB路径下覆盖原文件即可
上面配置好后,打开license,如下图
在mykingdee上申请license《10天无需审核,》10天《180天需审核,注意本机使用不要勾
选异地协同,在邮件中得到license.dat后引入license
9:设置IE
一般PLM装好后打开网页一直提示要下载安装主要是这项没有设置工具- internet选项
注意去掉后面https的选项
在IE的工具—》弹出窗口组织程序—》选择关闭弹出窗口阻止程序
10:访问PLM,安装客户端
重要:首先要打开且不要关闭,PLM使用过程中,PLM服务器这个服务要一直
开着
登录地址: http://服务器地址/PLM/login.aspx
点击确定
安装完毕后点击返回登陆页面
点击立即更新
更新完毕后点击返回登陆页面
在登录页面输入默认管理员用户名和密码:用户名:admin,密码:kingdee
见到下面的页面已经证明安装成功了
11:配置FTP
在PLM界面中选择配置---》展开配置信息—》打开电子仓库—》点击001前面的图标打开设置画面,主机名称填上服务器IP或者电脑名称,注意作为服务器不能填写localhost,在自己使用的个人电脑上才可以这样设置,FTP主路径填上自己FTP文件夹存放的目录即可,其
他都无需改变
12:还原demo库
如果做完以上工作后,还懒得自己去搭建系统架构的可以找个demo数据库放上去低版本数据库数据附加到高版本数据库上的方法
Demo数据后面必须是.bak 的,如果没有后缀名加上.bak 后缀名
在plm数据库上点右键-----》还原数据库
还原的过程中如果出现错误,则先停掉IIS再试
还原demo库后电子仓需要按照上面11步重新调整。

相关文档
最新文档