Technique Command

Use this command to select an electrochemical technique.

This command presents an Electrochemical Techniques dialog box:

The following options allow you to select an electrochemical technique:

Technique Selection

Select the electrochemical technique you want to use. This box lists the techniques available in the instrument. Double clicking the technique you want to select is equivalent to selecting the technique and clicking the OK button.

Polarographic Mode

Check this box will enable the polarographic mode. In the polarographic mode, the mercury drop will be allowed to grow and be dislodged for every data point.

Only a few techniques are allowed to have polarographic mode: Sampling Current (Staircase) Polarography (SCP), Differential Pulse Polarography (DPP), Normal Pulse

________________________________________________________________________ Polarography (NPP), Differential Normal Pulse Polarography (DNPP), A.C. Polarography (ACP), and Second Harmonic A.C. Polarography (SHACP).

Once polarographic mode is enabled, stripping mode is disabled. In order to set stripping mode by using the Stripping Mode command in Control Menu, you have to uncheck the polarographic mode.

This command has a toolbar button:

________________________________________________________________________

Parameters Command

Use this command to set experimental parameters.

This command presents a Parameter dialog box so you can select the parameters you want to use.

Depending on the technique, the parameters dialog box will be different. The followings are the parameters for different techniques:

Parameters for Cyclic Voltammetry

Parameters for Linear Sweep Voltammetry

Parameters for Sampled Current Voltammetry

Parameters for Tafel Plot

Parameters for Chronoamperometry

Parameters for Chronocoulometry

Parameters for Differential Pulse Voltammetry

Parameters for Normal Pulse Voltammetry

Parameters for Differential Normal Pulse Voltammetry

Parameters for Square Wave Voltammetry

Parameters for A.C. Voltammetry

Parameters for 2nd Harmonic A.C. Voltammetry

Parameters for Amperometric i-t Curve

Parameters for Differential Pulse Amperometry

Parameters for Double Differential Pulse Amperometry

Parameters for Triple Pulse Amperometry

Parameters for Integrated Pulse Amperometric Detection

Parameters for Bulk Electrolysis with Coulomtery

Parameters for Hydrodynamic Modulation Voltammetry

Parameters for Sweep-Step Functions

Parameters for Multi-Potential Steps

Parameters for A.C. Impedance

Parameters for Impedance - Time

Parameters for Impedance - Potential

Parameters for Chronopotentiometry

Parameters for Chronopotentiometry with Current Ramp

Parameters for Multi-Current Steps

Parameters for Potentiometric Stripping Analysis

Parameters for Open Circuit Potential - Time

For details of the parameters of each technique, see the description of individual dialog box of related techniques.

This command has a toolbar button: