Technique Command
Use this command to select an electrochemical technique.
This command presents an Electrochemical Techniques dialog box:
The following options allow you to select an electrochemical technique:
Technique Selection
Select the electrochemical technique you want to use. This box lists the techniques available in the instrument. Double clicking the technique you want to select is equivalent to selecting the technique and clicking the OK button.
Polarographic Mode
Check this box will enable the polarographic mode. In the polarographic mode, the mercury drop will be allowed to grow and be dislodged for every data point.
Only a few techniques are allowed to have polarographic mode: Sampling Current (Staircase) Polarography (SCP), Differential Pulse Polarography (DPP), Normal Pulse
________________________________________________________________________ Polarography (NPP), Differential Normal Pulse Polarography (DNPP), A.C. Polarography (ACP), and Second Harmonic A.C. Polarography (SHACP).
Once polarographic mode is enabled, stripping mode is disabled. In order to set stripping mode by using the Stripping Mode command in Control Menu, you have to uncheck the polarographic mode.
This command has a toolbar button:
________________________________________________________________________
Parameters Command
Use this command to set experimental parameters.
This command presents a Parameter dialog box so you can select the parameters you want to use.
Depending on the technique, the parameters dialog box will be different. The followings are the parameters for different techniques:
Parameters for Cyclic Voltammetry
Parameters for Linear Sweep Voltammetry
Parameters for Sampled Current Voltammetry
Parameters for Tafel Plot
Parameters for Chronoamperometry
Parameters for Chronocoulometry
Parameters for Differential Pulse Voltammetry
Parameters for Normal Pulse Voltammetry
Parameters for Differential Normal Pulse Voltammetry
Parameters for Square Wave Voltammetry
Parameters for A.C. Voltammetry
Parameters for 2nd Harmonic A.C. Voltammetry
Parameters for Amperometric i-t Curve
Parameters for Differential Pulse Amperometry
Parameters for Double Differential Pulse Amperometry
Parameters for Triple Pulse Amperometry
Parameters for Integrated Pulse Amperometric Detection
Parameters for Bulk Electrolysis with Coulomtery
Parameters for Hydrodynamic Modulation Voltammetry
Parameters for Sweep-Step Functions
Parameters for Multi-Potential Steps
Parameters for A.C. Impedance
Parameters for Impedance - Time
Parameters for Impedance - Potential
Parameters for Chronopotentiometry
Parameters for Chronopotentiometry with Current Ramp
Parameters for Multi-Current Steps
Parameters for Potentiometric Stripping Analysis
Parameters for Open Circuit Potential - Time
For details of the parameters of each technique, see the description of individual dialog box of related techniques.
This command has a toolbar button: