丹佛斯新型涡旋压缩机50-60Hz R407C R22 R410A 选型及应用指南(40P)
混合制冷剂R407C
HFC-407c一.产品简要介绍:产品名称: R407C产品类别: HFC化学成份:四氟乙烷/五氟乙烷/二氟甲烷混合物安全等级: A1UN编号: 811-97-2CAS号: 811-97-2/354-33-6/75-10-5包装规格:一次性钢瓶25lb/11.3kg;可回收钢瓶400L,926L;ISO-坦克。
二.产品详细介绍:R407C是替代R-22的HFC类制冷剂,应用于容积式系统,如新型或现有住宅、商用空调及热泵中。
R407C提供相似于R-22的性能表现,可用于替换现有R-22空调系统。
R407C也可用于现有的蒸发温度高于+20°F (-7℃)的中温应用中替代R-502。
1.产品信息:R-407C 替换 R-222.应用:(1)容积式系统:(2)新型或现有的住宅、商用空调;(3)新型或现有的住宅、商用热泵(4)现有中温应用。
3.优点: 制冷能力及能效与R-22相似。
4.润滑油使用建议: POE5.产品物理性质及质量指标产品名称:混合制冷剂R407C物理性质:分子量86.2沸点, °C-43.8临界温度, °C87.3临界压力, Mpa 4.63液体比热, 30°C, [KJ/(kg•°C)] 1.51破坏臭氧潜能值(ODP)0全球变暖系数值(GWP)0.17包装规格:一次性钢瓶25lb/11.3kg;可回收钢瓶400L,926L;ISO-坦克。
质量指标:纯度, %≥99.8水份, PPm≤10酸度, PPm≤1蒸发残留物, PPm≤100外观无色,不浑浊气味无异臭用途:可替代R22。
r407c和r22冷凝温度
r407c和r22冷凝温度摘要:1.了解r407c和r22冷凝温度的基本概念2.比较r407c和r22冷凝温度的差异3.分析r407c和r22冷凝温度在实际应用中的优缺点4.总结r407c和r22冷凝温度在我国空调行业的现状及发展趋势正文:在空调行业中,冷凝温度是衡量制冷系统性能的一个重要参数。
本文将围绕r407c和r22这两种制冷剂的冷凝温度进行比较和分析,以期为读者提供有益的参考。
首先,我们来了解一下r407c和r22的基本概念。
r407c是一种环保型制冷剂,适用于家用和商用空调系统。
它由三种成分组成,分别是丙烷(R227)、氟利昂(R125)和溴化乙烯(R134a),其冷凝温度一般在40℃左右。
而r22是一种传统的制冷剂,冷凝温度在50℃左右。
接下来,我们比较一下r407c和r22的冷凝温度差异。
从上面的介绍可以看出,r407c的冷凝温度要低于r22。
这意味着在同等条件下,r407c的制冷效果更好,能更好地满足用户的需求。
此外,r407c的环保性能也优于r22,因为它几乎不含有氯氟碳化合物(CFCs),对臭氧层的破坏较小。
然而,r407c和r22在实际应用中也存在一定的优缺点。
对于r407c来说,它的优点在于环保性能好、制冷效果强,但缺点是传热性能较差,对空调系统的能效比有一定影响。
而r22的优点在于传热性能较好,适合于高温环境,但缺点是环保性能较差,对臭氧层破坏较大。
在我国,随着环保政策的不断完善,r407c等环保制冷剂的应用逐渐增多。
尽管r22仍然在一些地区和领域使用,但总体来看,r407c的市场份额正在逐步扩大。
此外,一些新型制冷剂如r32、r1234yf等也在市场上崭露头角,未来有望成为空调行业的主流制冷剂。
总之,r407c和r22冷凝温度在空调行业中具有重要意义。
在选择制冷剂时,应综合考虑其环保性能、制冷效果、能效比等因素,以满足市场需求和政策要求。
丹佛斯压缩机型号有哪些?
艾赛尔空调型号识别:IM**U2A
IM ——M 系列 **——名义制冷量
U ——室内送风方式(U :上送风 F: 下送风) 2——压缩机数量(1:一台压机 2:两台压机) A ——冷凝方式(A :风冷 W :水冷 C :冷冻水机组)
2010-9-242
3.机组型号说明
S
W
S
B
30
A
D
D :下送风F :上送风
A :风冷系列W :水冷系列C :冷冻水系列
30:名义制冷量30kw 35/35:名义制冷量70KW
B=电压380-420/3/50E=220/3/60H=460/3/60I=380/3/60
S :直接膨胀式机组
W :不附带冷冻水盘管E :附带冷冻水盘管X :冷冻水系列机组
S :标准控制器G :图形控制器
谷轮压缩机型号辨识
ZR(T/H/D)36K3/C/F/H(E)-PFJ/TWD-522 ZR 全封涡旋+空调; ZF 全封涡旋+低温
CR 全封活塞+空调; VR 新型全封涡旋,仅用于中国
T/H/D-并联机组/卧式/数码
36K或12M-制冷量36//12=3HP 120/12=10PH E-可使用新工艺制冷剂,无E只能用R22 PFJ-单相,内置保护,220V/50HZ
TWD-三相,模块保护,380V/50HZ
性能参数
ZR系列压缩机技术参数。
R410a、R134a、R407C、R22特点比较与世界各国制冷剂淘汰时间表
R410a、R134a、R407C、R22特点比较与世界各国制冷剂淘汰时间表一、R410a、R134a、R407C、R22特点比较R134a是一种单一成分制冷剂,而R407C和R410A是混合制冷剂。
其中R410A 是R32和R125的混合物,R407C是R32,R125和R134a的混合物。
混合制冷剂的优点在于,可以根据使用的具体要求,对各种性质如易燃性、容量、排气温度和效能加以考虑,量身合成一种制冷剂。
选择制冷剂需要考虑的因素很多,因为选择任何一种制冷剂都会对系统的整体运行情况、可靠性、成本和市场接受度造成一定影响。
(本文来源制冷百科公众号)制冷剂由于其热传递和压降的不同而导致制冷剂传输性能的不同,这会最终在系统设计和系统性能上产生重大的影响。
下面列出了各制冷剂一些重要性质的比较,接下来我们将简要探讨其重要的性能特点。
R134a的容量比R22小,压力比R22低。
由于这些特点,相同能力的R134a空调需要配置一台更大排气量的压缩机,更大的蒸发器、冷凝器和管路。
最终所导致的是,制造和运行一个和R22相同冷量的系统,R134a系统会需要更高的成本。
R407C的容量和压力都和R22比较接近。
因此,只要简单调整系统设计就能使原R22系统也适用于R407C系统。
不过,系统能效比会较原系统降低约5%。
这是由于相对于其他制冷剂,R407C会有高达6度的温度漂移。
因此R407C系统在同等标准冷凝器和蒸发器时均会减少热传递,影响系统能效比。
R410A的容量和压力高于R22,运行压力高出50%-60%。
高压力和高气体密度带来的结果是,不但可以用更小排气量的压缩机,还可以用更小直径的管路和阀门。
高压排气阀的使用消除了系统冷凝高压带来的隐患。
厚压缩机壳体使系统经受更高的运行压力。
压缩机造得厚重些还有一个好处,即R410A的运行噪声比R22压缩机明显地低2-4个分贝。
与R22系统相比,R410A系统有个显著的热传递优势—蒸发器的热传递高35%,冷凝器高5%。
R404A和R407A冷冻涡旋式压缩机性能比较
R404A和R407A冷冻涡旋式压缩机性能比较
徐虹玲
【期刊名称】《制冷与空调》
【年(卷),期】2013(013)007
【摘要】对制冷剂R404A与R407A的热物理特性进行比较,探讨R407A应用于冷冻涡旋式压缩机的可行性,并对这2种制冷剂涡旋式压缩机进行测试,根据容积效率、等熵效率、排气温度、压缩机电流等参数的比较分析,为R407A涡旋式压缩机的开发提供参考依据.
【总页数】4页(P52-54,99)
【作者】徐虹玲
【作者单位】丹佛斯(天津)有限公司
【正文语种】中文
【相关文献】
1.R404A在我公司冷冻机上的使用情况 [J], 伏春干
2.冷冻冷藏用制冷剂R404A的替代品对比分析 [J], 张乐平
3.吸气过热对R404A涡旋式压缩机性能影响的研究 [J], 张剑飞;秦妍;刘忠赏
4.R507A,R404A与R22在低温冷冻工况下的性能比较 [J], 卢智利;Chin Soon wee;孙蔼军;李梦玲;曹霞;徐巍;莫浩成;胡炎钧
5.R507A,R404A与R22在低温冷冻工况下的性能比较 [J], 卢智利;Chin Soon wee;孙蔼军;李梦玲;曹霞;徐巍;莫浩成;胡炎钧
因版权原因,仅展示原文概要,查看原文内容请购买。
丹佛斯压缩机选型
丹佛斯压缩机选型丹佛斯压缩机是丹佛斯工业集团旗下一重要产品,它在德国、斯洛文尼亚和墨西哥设有三家工厂,生产家用冰箱、商用冷柜、空调用小型制冷压缩机,功率范围从1/0HP-2HP,使用R12,R22,R502,R134a、R404A、R600a等制冷剂。
丹佛斯压缩机目前被广泛应用于冷冻、冷藏陈列柜,自动贩售机,车船用冷藏,家用、商用冰箱,制冷机,除湿机,低温实验设备以及专用低温设备等。
丹佛斯压缩机特点:——黑色的丹佛斯压缩机以其体积小、重量轻、噪音低、效率高、寿命长而享誉世界制冷行业,尤其是丹佛斯压缩机的抵噪音设计,高效率和节能的象征。
1、丹佛斯压缩机使用高能效比的旋转式压缩机及电机(日本技术),省电10%以上。
2、丹佛斯压缩机卧式系列可获得最大的有效容积。
3、丹佛斯压缩机优化设计结构紧凑可直接安装于设备内部,减少安装费用省时省力。
4、丹佛斯压缩机应用范围广。
5、丹佛斯压缩机充实的功能部件与保护装置,噪音低、安全可靠。
SC 104L2674 SC12C 385W 12.87 SC 104L2848 SC15CM 495W 15.28 SC 104L2120 SC18CM 495W 17.69 SC 104L4079 SC15/15CM 2×495W 2×15.28 SC 104L4081 SC18/18CM 2×495W 2×17.69 SC 104L2529 SC10D 385W 10.29 SC 104L2694 SC12D 470W 12.87NL 105G6660 NL6.1MF 6.13 NL 105G6772 NL7.3MF 270W 7.27 NL 105G6879 NL8.4MF 292W 8.35 NL 105G6885 NL10MF 320W 10.1PL 101G0251 PL35GTL 102G4350 TL3G 95W 3.13TL 102G4452 TL4G 110W 3.86TL 102G4450 TL5G 140W 5.08 FR 103G6660 FR6G 150W 6.23 FR 103G6680 FR7.5G 175W 6.93 FR 103G6780 FR8.5G 215W 7.95 FR 103G6880 FR10G 275W 9.05FR 103G6980 FR11G 275W 11.15 SC 104G8000 SC10G 250W 10.29 SC 104G8240 SC12G 315W 12.87 SC 104G8520 SC15G 385W 15.28 SC 104G8820 SC18G 495W 17.69 SC 104G8140 SC21G 550W 20.95TL 102U2071 TL4CLFR 103U2670 FR6CL 215W 6.23 FR 103U2790 FR7.5CL 235W 6.93 FR 103U2890 FR8.5CL 275W 7.95 NL 105F3710 NL7CLX 235W 7.27 SC 104L2523 SC10CL 315W 10.29 SC 104L2623 SC12CL 385W 12.87 SC 104L2697 SC12CLX.2SC 104L2853 SC15CL 495W 15.28 SC 104L2854 SC15CLXSC 104L2897 SC15CLX.2SC 104L2123 SC18CL 495W 17.69 SC 104L2197 SC18LX.2SC 104L2195 SC18LX.2SC 104L2322 SC21CL 590W 20.95 SC 104L2506 SC10MLX 470W 10.29 SC 104L2606 SC12MLX 12.87 SC 104L2869 SC15MLX 15.28 SC 104L2139 SC18MLX 17.68 FR 103U2680 FR6DL 275W 6.23 SC 104L2525 SC10DL 385W 10.29 SC 104L2625 SC12DL 495W 12.87。
R22、R404A与R407F制冷剂压缩机性能对比
R22、R404A与R407F制冷剂压缩机性能对比徐松;高飞;刘忠赏;杨晓倩【摘要】分析R22、R404A与R407F制冷剂的物理性质,并采用涡旋压缩机进行试验测试. 结果表明:在高温应用上, R22、R404A和R407F制冷能力数值相近,R407F制冷系数比R22、R404A稍低;而在低温应用上,R407F制冷能力、制冷系数比R22、R404 A都低.【期刊名称】《低温与特气》【年(卷),期】2016(034)001【总页数】4页(P7-10)【关键词】R22;R404A;R407F;性能【作者】徐松;高飞;刘忠赏;杨晓倩【作者单位】松下压缩机(大连)有限公司,辽宁大连116033;松下压缩机(大连)有限公司,辽宁大连116033;松下压缩机(大连)有限公司,辽宁大连116033;松下压缩机(大连)有限公司,辽宁大连116033【正文语种】中文【中图分类】TB61+2·低温与制冷·随着世界上各个国家、地区及组织对环境保护措施逐步实施及加强,制冷行业的环境保护工作也在积极开展,尤其在制冷剂替代方面工作正在全面推进。
无论是在空调行业,还是冷冻冷藏行业都在积极推进制冷剂的环保性替代,各种环保制冷剂产品快速推出,无论是天然制冷剂CO2,还是HFO类制冷剂,还是过渡性制冷剂R32、R410A、R407F、R417A等。
在中国,商用空调上广泛采用的是R22制冷剂,而在商业及工业低温冷冻上所采用的制冷剂主要也是R22,一部分采用R404A。
根据《蒙特利尔议定书》要求,以R22为代表的HCFCs制冷剂,因其对臭氧层的破环已被列为限制使用,中国目前正在加快淘汰R22制冷剂,而R404A又具有较高的GWP(3800)值[1],不是可以长久替代使用的制冷剂。
R407F是一种三元混合物,可在各种商用制冷上应用,物理及热工性能与R22、R404A接近,可直接用于现有制冷系统改造。
它的ODP为0,GWP为1824,或可作为过渡性替代制冷剂应用。
丹佛斯涡旋压缩机组
丹佛斯涡旋压缩机组丹麦“丹佛斯”全封闭涡旋制冷压缩机组丹麦“丹佛斯”全封闭涡旋风/水冷压缩冷凝机组丹麦“丹佛斯”全封闭涡旋压缩机风/水冷冷凝压缩机组采用“丹佛斯”系列全封闭制冷压缩机,广泛适用于保鲜,冷藏,冷冻,速冻、商用冷冻冷藏,空调等制冷领域。
我们为您提供丹佛斯涡旋各型号的制冷机组,以供您的不同需求,欢迎您的来电垂询!丹麦“丹佛斯”涡旋风/水冷冷凝压缩机组产品简介:*选用丹麦“丹佛斯”全封闭涡旋制冷压缩机。
*冷凝器采用高效换热盘管,铝翅片胀管紧密接触换热效率高,外壳喷塑,防腐耐用。
*机组标准配置:储液器,风冷冷凝器,干燥过滤器,电磁阀,视液镜,压力控制,压力表,可配置中间冷却器。
*可根据要求增加配置,可选配置:油液分离器,气液分离器,回气过滤器,冷凝压控。
*制冷剂:R22,R404A可选。
1.蒸发温度范围+5℃~-25℃冷凝温度范围≤65℃2.压缩机保护装置采用内置式保护器和安全阀 3.60Hz时制冷量等于50Hz时制冷量的1.2倍丹佛斯涡旋压缩机组易安装和维护.宁静运行.长寿命(在SEET测试).性能稳定.可在高温环境下运行.HOOP是有高温过热保护技术.有热油保护器感应到最真实的排气温度,它能更快的做出反应,并且控制在较低的电机运行温度下,压缩机寿命更长.自动喷油系列是确保涡盘供油量,与制冷剂流量无关,在高压比时降低排气温度,改善涡盘润滑防止涡盘过热. 特点:高能效.重量比同类品牌减轻25%.专利的HOOP-热油保护技术.几乎没有启动和停机噪音.比同类品牌少1/3的零部件.无螺纹连接件.比同类品牌少一半的焊接.涡盘自定位.涡盘自动喷油系统.涡盘热保护Danish Danfoss hermetic scroll refrigeration compressor unit Danish Danfoss hermetic scroll air / water-cooled condensing unitDanish \series hermetic refrigeration compressor. Widely used in fresh keeping, cold storage, frozen, air conditional and other refrigeration area. We offer varies kind of Danfoss refrigeration unit.The introduction of Danish Danfoss hermetic scroll air / water-cooled condensing unit:Choose Danfoss series hermetic refrigeration compressor.Condensator adopts high effective heat exchanger coil. Aluminum finnedtube expanding in close contact with high heat exchange. The shell sprayplastic with high corrosion resistance.The standard configuration of the unit: receiver, air-cooled condenser, filter dryer, solenoid valve, sight glass, pressure controller, pressure gauge.Optional configuration: oil liquid separator, air liquid separator, air return filter, condenser and pressure control.Extra fittings can be added according the requirements. Refrigerant: R22, R404A are optional.1. Evaporation temperature range +5 ℃ ~ -25 ℃, condensing temperature range ≤ 65 ℃.2. Compressor protection device adopts inner protection and safety valve.3. The cooling capacity in 60Hz is equal to 1.2 times to the cooling capacity in 50Hz.Danmark Danfoss scroll compressor refrigeration unitDanfoss scroll compressor refrigeration unit is easy to install and maintenance. On the SEET test result shows long-period. Stable performance can be run under the environment of high temperature. Hoop with overheating protection technology.Characteristic: Energy efficiency. The weight lighter 25% then similar brands. HOOP- oil protection technology patent. Almost no start and stop thenoise. No thread connector. Less than half the welding than similar brand. Scroll self position.感谢您的阅读,祝您生活愉快。
百福马压缩机2012样本
数据修改不预先通知 完整的详细信息请参考数据表在线生成: /odsg 8
应用指南 60 Hz 参数
机型 SM084 SM090 SM100 SM110 SM112 SM115 SM120 R22 单台 SM124 SM125 SM147 SM148 SM160 SM161 SM175 SM/SY185 SY240 SY300 SZ084 SZ090 SZ100 SZ110 SZ115 SZ120 R407C 单台 SZ125 SZ148 SZ160 SZ161 SZ175 SZ185 SZ240 SZ300 SZ380 TR = 冷吨 COP = 性能系数 EER = 能效比 额定工况 制冷剂 频率 标准额定工况 蒸发温度 冷凝温度 过冷 过热 名义冷量 60 Hz TR 7 7.5 8 9 9.5 9.5 10 10.5 10 12 12 13 13 14 15 20 25 7 7.5 8 9 9.5 10 10 12 13 13 14 15 20 25 30
目录
百福马®涡旋压缩机工作原理 特征 压缩机型号说明 命名 技术参数 50 Hz 参数 60 Hz 参数 尺寸 SM/SZ 084-090-100-110-120 SM 112-124-147* SM 147 代码 3 SM/SZ 115-125 SM/SZ 148-161 SM/SZ 160 SM/SZ 175-185 & SY185 SY/SZ 240-300-380 接口类型 电气参数,连接和接线 电机电压 接线 IP 等级 接线盒温度 三相电参数 丹佛斯MCI软启动控制器 一般接线信息 电机保护 电压不平衡 认证 许可和认证 压力设备认证 97/23/EC 低电压认证 2006/95/EC 机械认证 2006/42/EC 内部空余容积 运行状况 制冷剂和润滑油 电机电源 压缩机环境温度 运行区间 在中点温度下的运行范围 排气温度保护 高低压保护 启停限制 5 6 7 7 8 8 9 10 10 11 11 12 13 14 15 16 17 18 18 18 19 19 20 21 22 24 25 26 26 26 26 26 26 27 27 28 28 28 30 32 32 33
制冷剂R407C与R410A性能比较分析
制冷剂R407C与R410A性能比较分析在当前,R600a已经成为最主流的冷库制冷剂时,在国内众多空调企业也面临着抉择,到底是先用R410a进行暂时性的替代,还是找更环保的制冷剂产品进行最终替代?下面就来看看制冷剂R407C与R410A性能比较分析。
R407C和R410A的传热性能比较R410A具有很好的传热性能,R410A的蒸发传热系数和冷凝传热系数高于R407C,在很多应用场合R410A的传热性能还优R22。
蒸发试验研究发现,R410A在光滑水平管内的传热系数比R407C高50%左右;与R22蒸发试验结果相比,R410A的传热系数要比R22高10%~50%。
使用具有微型肋片的水平管,R410A的传热系数比光滑管提高了80%~150%。
板式换热器的蒸发试验也证实了R410A传热性能的优越,在相同条件下R410A的传热系数比R22的传热系数要高0~15%。
冷凝试验则显示,在光滑管内R410A的冷凝传热系数比R407C冷凝传热系数高20%。
在光滑管外,R410A的冷凝传热比R407C的冷凝传热高35%~50%,比R22高约11%~17%;然而R407C的传热系数却比R22低24%~37%。
在具有微型肋片的管外,R410A 的冷凝传热系数比R407C高35%~55%,比R22高3%~7%,相反,R407C的传热系数比R22低33%~52%。
R407C传热性能较差的事实还可以用现有设备的制冷剂替换试验结果来说明,在一台100kW制冷量螺杆式水制冷机组试验中发现R407C在管壳式冷凝器中的传热系数比R22小25%~51%。
R407C的传热系数低,其与它的非共沸性有关:一是在等压蒸发或冷凝时存在着较大的相变温度梯度,二是汽液两相之间存在着明显的浓度差。
R407C在蒸发或者冷凝时,不但要克服冷凝液层的热阻,还要克服相变温度梯度和汽液浓度差对传热带来的负面影响。
相变温度梯度是指在一定压力下混合物由饱和蒸汽变成饱和液态的温度差,R407C在大气压下的相变温度梯度约为7K。
Danfoss丹佛斯百福马压缩机[技巧]
Danfoss丹佛斯百福马压缩机(丹佛斯百福马 HP匹压缩机)优势:丹佛斯MLZ/MLM冷冻涡旋压缩机,采用了独特涡旋设计,且加工工艺机动性强,能够为恶劣的冷冻应用提供高能效的解决方案。
该系列的冷冻涡旋压缩机包含了11个型号的中温我选压缩机,这些涡旋压缩机都是专为商业冷冻应用所设计。
该系列压缩机设计时工程师就考虑到了冷冻应用的特殊性,针对常用供电条件,提供多种制冷剂选择(R404A-R134A-R507-R22),覆盖3.4到21kw(即从2-10HP)的冷量区间。
得益于专门针对冷冻的特殊设计,MLZ/MLM涡旋压缩机具有很多强大的优势,高效电机和优化的涡旋型线,使该系列压缩机在常用工况下能耗更低,并为冷冻应用提供更大的制冷量丹佛斯百福马制冷涡旋压缩机型号名称丹佛斯百福马压缩机 2.5匹MLM019T4LP9丹佛斯百福马压缩机 3匹 MLM021T4LP9丹佛斯百福马压缩机 3.5匹MLM026T4LP9丹佛斯百福马压缩机 4匹MLM030T4LC9丹佛斯百福马压缩机 5匹MLM038T4LC9丹佛斯百福马压缩机 6匹MLM045T4LC9丹佛斯百福马压缩机 7匹MLM048T4LC9丹佛斯百福马压缩机 8匹MLM058T4LC9丹佛斯百福马压缩机 9匹MLM066T4LC9丹佛斯百福马压缩机 10匹MLM076T4LC9丹佛斯百福马压缩机 3匹MLZ021T4LP9丹佛斯百福马压缩机 3.5匹MLZ026T4LP9丹佛斯百福马压缩机 4匹 M LZ030T4LC9丹佛斯百福马压缩机 5匹MLZ038T4LC9丹佛斯百福马压缩机 6匹MLZ045T4LC9丹佛斯百福马压缩机 7匹MLZ045T4LC9丹佛斯百福马压缩机 7.5匹MLZ058T4LC9丹佛斯百福马压缩机 10匹MLZ076T4LC9丹佛斯Danfoss压缩机产品特点:●丹佛斯Danfoss SC系列R134a制冷剂的压缩机是高低蒸发温度通用的压缩机,蒸发温度从+15度到-30度左右,应用范围非常宽广。
冷媒区别与要求R22 R410A R407C
四、制冷剂的发展方向
近年来,中国HCFCs消费量不断攀升。2009年,中国HCFCs消费量占发展中国家整体消费量的比例已 经超过58%。R22是目前中国家用空调行业使用最多的制冷剂,也是中国家用空调行业HCFCs替代的主 要对象。 根据蒙特利尔议定书的要求,中国HCFCs的控制目标是:到2013年,冻结国家层面HCFCs消费量在2009 年和2010年的平均值上;到2015年,在此基础上削减10%。据估算,实现第一阶段整体削减目标,意味 着中国HCFCs消费总量的17%将受到控制。 在最近召开的蒙特利尔议定书多边基金执行委员会第64次会议上,中国和多边基金执行委员会达成 一致意见,在不损耗臭氧层的前提下,通过采用气候友好的替代技术,减少温室气体排放,为应对全 球气候变化做出重要贡献。 目前,世界各国已经意识到HCFCs替代不能仅局限于淘汰损耗臭氧层的物质,还需要考虑替代技术对 气候的影响。”王雷表示,减少温室气体排放是全球环境保护最大、最突出、最热点的议题之一。 “美国环保局已经准备好1个提案,明确提出为了减少温室气体排放,应当将逐步削减HFC物质的计划 纳入蒙特利尔议定书框架内。并且,美国环保局已经在多个国际会议上宣传这一议案,开展双边交流。 据说部分国家已经明确表示支持这个提案,这意味着R410A等HFC物质进入受控制物质名单是迟早的 事。” 不少空调企业也意识到这个问题。海信空调研发中心国内产品所所长赵可可认为,尽管R410A已经成 为未来几年主流的空调制冷剂,也是现阶段最成熟的替代方案,但是由于R410A的GWP值较高,最终只 能作为一种过渡产品使用。王雷表示,目前中国以节能作为减排温室气体的主要途径,但是这不等于 国家不重视化学品的减排作用,国家有关部门正在进行这方面的研究。 目前行业比较认可的气候友好型制冷剂主要有R290、R32、CO2、HFO-1234yf(目前主要应用于汽车 空调领域)等。对于制冷剂的未来发展,目前业界观点并不统一。2010年召开的“空调器HCFCs替代技 术国际研讨会”为各种观点提供了1个充分展示的平台。 对HCFCs替代技术的争论在会上不绝于耳,又以对自然工质制冷剂的研究探讨最为激烈。
常用制冷剂R22、134a、R404A、R407C、R410A的特性(技术分享)
常用制冷剂R22、134a、R404A、R407C、R410A的特性(技术分享)常用制冷剂R22、134a、R404A、R407C、R410A的特性1. R22R22是一种中温制冷剂,它的标准沸点为-40.8°C; 水在R22中的溶解度很小,与矿物油互相溶解; R22不燃烧,也不爆炸,毒性很小; R22参透能力很强,并且泄漏难以发现.R22的ODP和GWP比R12小的多,属于HCFC类物质,对臭氧层仍有破坏作用.由于R12已逐步禁用,R22正作为某些CFC制冷剂的过渡替代物在使用。
2. 134aR134a是一种新型制冷剂,它的标准沸点为-26.5°C; R134a 安全性好、无色、无味、不燃烧、不爆炸、基本无毒性、化学性质稳定; R134a气化潜热大、比定压热容大、具有较好制冷能力;饱和气体积大,相同排气量压缩机的制冷剂的质量流量小;热导率较高、热传导性能好;粘度低、流动性好;对臭氧层没有破坏作用、温室效应比R22小。
R134a对金属的腐蚀作用比较小,稳定性好,也不溶于水,但R134a不溶于矿物油,需用POE或PAG润滑油。
R134a属HFC类制冷剂,按当前的国际协议可长期使用。
值得指出的是R134a的GWP(全球变暖潜能值)为1600,仍比较头。
注:环境性能及指标解释。
ODP表示制冷剂消耗大气层臭氧分子潜能的程度。
GWP表示制冷剂对气候变暖影响的潜能指标值。
TEWI总体温室效应值,它由两项构成:a 直接使用制冷剂产生的温室效应;b制冷机使用期内电厂发电产生的间接温室效应。
3. 混合制冷剂常用的混合制冷剂有R404A、R407C、R410A等。
其物理性质均不可燃,属HFC类制冷剂,压缩机须充注聚酯类(POE)润滑油。
R404A是由R125、R134a和R143a三种工质按44%、52%和52%和4%的质量分数混合而成,可作为R22和R502的替代工质。
美国杜邦公司和英国ICI公司产品的商品名分别为SUVA-HP62、FX-70。
涡旋压缩机在R410a方面的应用
Scroll Compressors in R410A ApplicationsAbstractEU regulations are now requiring replacement of R22 within a few years, and the choice of replacement is R407C, R410A, or R134a. Extensive tests have shown that there are significant benefits with air conditioning systems using R410A. This is primarily due to superior heat transfer coefficients and lower pressure drops than with R407C. Scroll compressors suitable for R410A are available, and these compressors, when used in a system optimised for R410A can deliver a performance better than R22.IntroductionEuropean Regulations for phase out of CFCs and HCFCs are now in place and the timescales are shorter than those demanded by the latest Montreal Protocol revision. Under EC Regulation 2037/2000, refrigeration and air conditioning equipment for use with R22 cannot be sold in the EC after January 2001, with an exception for air conditioning systems having less than 100kW capacity, which are allowed until the end of 2001. Reversible air conditioning equipment has a further extension to the end of 2003. Suppliers of R22 will not be allowed to market new material for service of systems after 2009, and the cut off date for supplying recycled R22 is 2014.These timescales have had the effect of forcing European suppliers to move quickly in the designing, testing and placing on the market of systems containing alternative HFC refrigerants, which have zero ozone depletion potential.HFC Replacement OptionsThe HFC options for new air conditioning equipment have, by general consensus, been reduced to R407C, R134a and R410A. For refrigeration applications R404A is preferred because it has a better low temperature efficiency, and lower discharge temperatures, but in air conditioning R407C has a better efficiency characteristic.A theoretical COP can be calculated for comparison purposes by using the thermodynamic properties of the refrigerant. Fig. 1 shows a comparison of the major candidates on this basis; a standard vapour compression cycle with a 100% efficient compressor is taken to make the calculations. This enables comparison of the efficiency effect of the thermodynamic properties of the refrigerant to be made. It can be seen from the diagram that none of the replacement HFCs matches R22 in this respect, although R134a comes close. The second point to notice is that R410A is less efficient than R407C. The reason for this is relatively low critical temperature, 71°C, of R410A. For further information about refrigerant properties, see Reference 1.Fig.1 Comparison of Theoretical COP for Refrigerants, based on Condensing Temperature 40°C, Suction Superheat 20K, zero SubcoolingThere are several other vital properties of a refrigerant which contribute towards the overall system behaviour. They are summarised in the table shown in Fig 2. The first is operating pressure. R134a has a lower pressure than R22, and it requires a larger displacement compressor and larger tubing to achieve the same performance as for R22. These factors tend to increase system cost, although there are some applications for which R134a is particularly suited, such a screw chillers. R410A has a pressure considerably above that of R22, which should tend to reduce system cost. However it has taken time for proven high pressure components suitable for R410A to become available. This, combined with the fact that the theoretical COP is poorer, has lead to the extensive adoption of R407C as an R22 replacement. A further benefit of high pressures is that there is a reduction in the effect of pressure drops. This can either result in smaller tubing for equivalent pressure drop effect, or lower losses if the same size tube is used.Fig 2. Refrigerant Properties and System Effects, Reference R22R407C has a similar pressure to R22, making it an obvious choice, with little system redesign necessary. A property which needs consideration with R407C is the temperature glide, which makes careful definition of temperatures necessary. A full explanation of the effect of temperature glide on compressor and system performance definition is given in Reference 2. Some concerns about the effects of composition changes with glide refrigerants have been expressed, but system designers have demonstrated that R407C works perfectly well in properly designed installations, with an efficiency close to that of R22.Merits of R410AThe next environmental issue which manufacturers will need to face will certainly be energy efficiency, because the efficiency is directly related to carbon dioxide emissions from power generation, and most countries are committed to reducing these emissions under the Kyoto agreement. In the USA energy efficiency of air conditioning has always had a high profile. Efficiency regulations will play an important role in moving the U.S. market away from use of R22. Recently enacted ASHRAE 90.1 standards will increase efficiency demands on commercial A/C systems by up to 20%, and a new, higher minimum efficiency regulation is under consideration for the U.S. residential market.In order to appreciate why R410A has the potential for improvements over R22 and R407C, it is necessary to consider the relative effects on parameters round the system. Copeland has been heavily involved in evaluating R22 alternatives for both residential and commercial air conditioning applications, and the results of those studies can be summarised with reference to Fig 3. The nominal operating conditions for the tests were: evaporating temperature, 7C, condensing temperature 40C with 11K superheat and 8.3K subcooling. The first parameter is the theoretical efficiency, and as already discussed this is approximately 4% lower than R22, and is shown as a negative in Fig 3.Fig.3 Percentage Efficiency Effects for R410A, Reference R22Compressor testing has demonstrated that there can be a gain of up to 2% in compressor efficiency in the R410A system. This is shown as a positive in Fig 3 and goes some way towards offsetting the negative refrigerant properties effect, although it should still be noted that the COP of the R410A scroll will generally be slightly below that of the R22 equivalent, as shown in Fig.2. The compressor COP is a combination of the compressor efficiency and the refrigerant properties.Now we move on to other system parameters. The superheat and subcooling will have a small effect as shown, due to refrigerant properties. By far the largest effect is the major gain in performance due to better heat transfer in the evaporator. This gain has the effect of raising the evaporating temperature by 2K. For the same air temperatures, the increased evaporating temperature with the R410A system improves system efficiency and capacity by a significant amount. There was also a small effect due to improved heat transfer in the condenser. The overall COP percentage improvement is shown in Fig 3 as 6% when referenced to the compressor only, or 5% for the system, which takes account of the fan power.Practical Considerations for R410AR410A operating pressures are 50% higher than R22 pressures. That means using gauges specifically designed for higher pressures and gives added importance to the quality of joint brazing during installation.Although it might seem that R410A's higher pressures would result in higher system temperatures, in fact, tests have shown the opposite. Under similar conditions, R410A systems actually ran at cooler temperatures than R22 systems.Because R410A systems in common with all other HFC systems use polyol ester oil, and cleanliness is important because POE oils are hydroscopic. That is, they readily absorb moisture, so units should be capped whenever possible, and exposure to the atmosphere should be kept to a minimum. This is normal good practice for all refrigeration systems.Compressors for R410ACopeland Scroll Compressors are available in 5 models which will deliver 5 to 15kW cooling (ARI conditions). Fig.4 shows a cross section of the “ZP” or R410A scroll, and the components which differ from the previous R22 model are indicated.Fig.4 ZP Scroll Compressor Showing Changes Made for R410AConclusionsOptimised system tests have shown R410A delivers higher system efficiency than R22. Its higher heat transfer coefficient and lower pressure drop allow for these performance gains. This means coil surface areas can be reduced while maintaining the same system efficiency.Actual field experience has confirmed that systems using Copeland Scrolls with R410A are more reliable, more efficient and offer greater sound reduction than those using R22. Its increasing use in the high-volume residential market, particularly in the USA should eventually drive down R410A's cost and provide stocking and service advantages in the commercial market as well.Thicker Top CoverHigh PressureDifferential IPR ValveRedesigned Lower CoverSmaller Scroll SetSmallerCounterweights Changed for R410ADischarge GasTemperature SensorReferences(1) Domanski, P A. “La Storia attuale e futura nell’impiego dei refrigeranti”, Congresso Internationale Della Refrigerazione, 4 maggio 1999, Milano(2) Hundy, G F and Vittal R., “Compressor Performance Definition for Refrigerants with Glide”. Proceedings of the 2000 International Refrigeration Conference at Purdue, 2000.。
多种丹佛斯涡旋压缩机
我司经营的制冷机组主要有主要产品:制冷配件、冷库配件、冰箱配件、空调配件、冷库工程、制冷压缩机经营品牌:阿斯帕拉,丹佛斯,卡士妥,百福马,三洋,美优乐,谷轮,泰康,东贝,富士豪等等。
水(风)冷全封闭涡旋式冷凝压缩机组采用天津Danfoss、百福马和美国Copeland全封闭涡旋压缩机为制冷主机,80%以上配件均为国际知名品牌,适用于10℃~-20℃的冷藏、冷藏库、制冰系统。
型号范围:在2HP-15HP,设备可以多机并联组合使用。
适用于多种制冷剂,如R22、R404、R507C等。
适用库温:+5至-20℃。
美优乐全封闭压缩机组丹佛斯/百福马全封压缩机美国谷轮全封闭压缩机济南冰雪制冷设备有限公司我公司可根据用户的需求,提供国内外不同品牌的制冷压缩机组,以满足不同的工艺要求。
欢迎来电来函咨询洽谈!济南冰雪制冷设备有限公司1、立式储液器型号:HL-1.2L~28L 接口:1/4″~1-3/8″品牌:HL 说明:丹佛斯涡旋压缩机储液器采用先进的自动焊接工艺,强度大,气密性好,进口配有旋转截止阀,耐腐蚀喷塑,可接受来图来样定做。
出厂价优惠销售2、卧式储液器型号:15L~60L,接口:5/8″~2-1/8″品牌:HL 说明:储液器采用先进的自动焊接工艺,强度大,气密性好,进口配有旋转截止阀,耐腐蚀喷塑,可接受来图来样定做。
出厂价优惠销售3、气液分离器型号:HA204、HA205、HA206、HA207、HA208、HA209、HA210、HA221、HA225、HA231接口:1/2″~3-1/8″品牌:HL 说明:气分需垂直安装,尽可能地靠近压缩机安装,进口连接蒸发器回气口,出口连接压缩机吸气口,内部为U型管独特设计,避免了液体进入压缩机形成液击,气分回油孔的设计和系统容量匹配以控制流入压缩机的液态制冷剂和油量,可接受来图来样定做。
出厂价优惠销售。
4、冷热交换型气液分离器型号:HAV2405、HAV2406、HAV2407、HAV2411、HAV2413、HAV2415 接口:1/2″~1-5/8″品牌:HL 说明:热交换管采用高效外螺纹管,具有最大的冷热交换量及超强的气液分离能力,可接受来图来样定做。
丹佛斯新一代高能效商用涡旋压缩机规格书
5
Nelico 涡旋压缩机规格书
4. SM147 基本参数
型号(见压缩机铭牌) 图号 吸排气管形式 吸气管 排气管 油视镜 油平衡管接口 放油口 低压表接口 内释压阀(IPR) 排量 净重 润滑油 最大测试压力(低压侧/高压侧) 最大测试压差 每小时最多启动次数 制冷剂加注量上限 允许使用的制冷剂
380-400/3/50, 460/3/60
340-440V@50Hz 1.05 欧姆 20.7 安培 29 安培 130 安培
内置过载、过载保护器
推荐力矩
油视镜 电源线端子/地线端子 地脚螺栓
50 Nm 3 Nm / 2 Nm
15 Nm
随机附件
固定组件(螺栓,螺母、垫片、橡胶垫,衬套) 润滑油(已加好) 安装指导
5. SM147 性能参数
冷凝温度 制冷量 W
电功率 W
电流 A
质量流量 kg/h
COP
蒸发温度
型号 SM124/SM147
额定性能(蒸发温度 to=7.2℃, 冷凝温度 tc=54.4℃)
制冷量
36038 W
输入功率
10.08 W
COP 电流
3.57 18.35 A
质量流量
817 kg/h
压力开关设定值 最大高压 最小低压 抽空循环低压 噪声数据
中间盖降低吸、排气之间的 传热
并减小高、低压差对定涡盘 造成的形变
专利设计的马达盖优化马达 冷却和油分离
新型气体流道提高对液击的 抵抗力
改善的下轴承中 心定位
新型聚四氟乙烯弹性 高低压密封
专门优化设计的涡盘
专利的马达中心 定位器
绕组底部被油冷却 降低的底座减小振动
丹佛斯对样本等印刷品中可能出现的错误不负责任。丹佛斯保有对产品和样本等更新的权利。此印刷品中的商标归相应公司
2013年丹佛斯Performer-M系列冷冻涡旋压缩机参数对照表
<p STYLE="TexT-ALiGn: left; mso-layout-grid-align: none" ALIGN="left"><span STYLE="FonT-FAMiLY: 宋体; mso-bidi-font-size: 10.5pt; mso-hansi-font-family: 'Times new roman'; mso-bidi-font-family: 宋体">
烟台凝新制冷科技有限公司一直坚持品牌战略,与丹佛斯中国签约也表明了烟台凝新坚持做高品质制冷设备的决心。</SPAN></P>
<p STYLE="TexT-ALiGn: left; mso-layout-grid-align: none" ALIGN="left"><span STYLE="FonT-FAMiLY: 宋体; mso-bidi-font-size: 10.5pt; mso-hansi-font-family: 'Times new roman'; mso-bidi-font-family: 宋体">
R22的替代制冷剂R407C及R410A的介绍
¸ Î ²ó É ¹ ø
实 机 性 能 比 较
条件
JIS标准条件 与R-22同样能力时 R-22=100
R-407C ¿ à ¸ ½¶ æ µ ñ Ò ¸ ° ã î ¹ ³ Î ¸ ¯ Ì Ê ³ ± COP± Å ä à ½ õ ¯ õ  à 90 89 99 98 ¿ à ¸ ½¶ æ µ ñ Ò ¸ ° ã î ¹ ³ Î ¸ ¯
5、水分溶解性与R22几乎相同、 比R12大。
R-407C
充填时的组成变化( 25 ℃) 液相充填
充填率%
R-407C
充填时的组成变化( 25 ℃) 气相充填
充填率%
R-410A
充填时的组成变化( 25 ℃) HFC-32的组成
充填率%
理论冷冻循环特性比较
Õ ò ä ½ ¿ Ë ¿ Ê ²Î ¢ ¶ ¾ ¦ ÷ Î Á ¶ ¾ ¦ Å Ã ´ ¯ Ò Ã ô Ë ± ¿ ´ Å ä ½ COP ² ¼ ½ ä ´ ± Á Û ¦ ¾ ¯  COP ² ¼  ¯ ² ¼ Á Û ¾ ¦ kPa kPa æ ¡ æ ¡ kJ/m3 kJ/m3 Õ ò ä ½ ÷ ¶ ÷ ¶ R-407C 499 2112 4.3 67.4 4.03 3014 5.03 3762 ²Ë ¢ ¿ ÷ Ë Á ¿ Å Ë ¿ ä Å ½ ² ´ Å Å ´ Å ´ ¿ ´ Ë Å R-410A 804 3061 0.07 72.5 3.69 4190 4.69 5326 HCFC-22 498 1943 0 70.3 4.14 3010 5.14 3737 0¡ æ 50æ ¡ 0æ ¡ 0æ ¡
5. 一般事项
1)绝缘电阻值
R407C和冷冻机油的体积固有电阻都较低,而 且跟以前的系统相比电阻值可能会下降,所以请用 商品进行确认。 2)已注入冷冻机油的压缩机长期保存 我们对压缩机的水份.残留空气进行控制,使 其保持少量的状态。但是在高温等环境下长时间放 置可能会出现水份侵入,油老化等现象。鉴于以上 情况,请在40℃下保存,保存时间为1年以内。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
这些严格保证了压缩机产品的高效,可靠和低噪音 水准。
性能
本指南中的百福马 H 系列压缩机采用柔性涡旋设 计,性能会根据最初运行时间的增加而改善。为
达到理想的性能,建议有 72 小时的磨合期。
5
应用指南 压缩机命名
压缩机命名
型号 HRH 应用 H: 高温/空调 系列 C: 轻商用 R: 家用(新机型) L: 轻商用(新机型) 制冷剂和润滑油 M: R22,烷基苯油 P: R407C,PE酯类油 H: R410A,PE酯类油 J: R410A,PVE醚类油 名义制冷量 单位kBtu/h,60Hz,ARI工况 类型 T: 优化工况7.2/54.4°C(45/130°F) U: 优化工况7.2/37.8°C(45/100°F)
规格 O36
电机 U1L
规格 P6 其他规格 视液镜 6 7 8 无 螺纹 无 油平 低压表 气平衡 放油孔 衡口 接口 接口 无 无 焊接 无 无 无 无 无 无 无 无 焊接
接口和电气接线 P: 焊接,铲型端子 C: 焊接,螺柱端子 电机保护 L: 内置电机保护 电机电压代码 1: 208-230V/1~/60Hz 2: 208-230V/3~/60Hz 4: 380-400V/3~/50Hz,460V/3~/60Hz 5: 220-240V/1~/50Hz 7: 500V/3~/50HZ,575V/3~/60Hz 9: 380V/3~/60HZ
涡旋式压缩是一个连续过程:在第二个圆周运动中, 一部分气体被压缩,另一部分气体正进入涡盘,还 有一部分气体正在被排出。
SUCTION
吸气
压缩 COMPRESSION
排气 DISCHARGE
丹佛斯涡旋压缩机采用先进的机加工、装配和工艺 过程控制技术。在对压缩机产品和工厂自身进行设 计时,优先考虑了高标准的可靠性和过程控制。
铭牌
序列号
S
产地 生产周 生产月份
03 09
K 12345
压缩机序号
6
应用指南 50Hz参数
型号 HRM032U4 HRM034U4 HRM038U4 HRM040U4 HRM042U4 HRM045U4 HRM047U4 HRM048U4 HRM051T4 HRM051U4 HRM054U4 HRM058U4 HRM060T4 HRM060U4 HLM068T4 HLM072T4 HLM075T4 HLM081T4 HCM094T4 HCM109T4 HCM120T4 HRP034T4 HRP038T4 HRP040T4 HRP042T4 HRP045T4 HRP047T4 HRP048T4 HRP051T4 HRP054T4 HRP058T4 HRP060T4 HLP068T4 HLP072T4 HLP075T4 HLP081T4 HCP094T4 HCP109T4 HCP120T4 HRH029U4 HRH031U4 HRH032U4 HRH034U4 HRH036U4 HRH038U4 HRH040U4 HRH041U4 HRH044U4 HRH049U4 HRH051U4 HRH054U4 HRH056U4 HLH061T4 HLH068T4 HLJ072T4 HLJ075T4 HLJ083T4 HCJ090T4 HCJ105T4 HCJ120T4 名义冷量 60 Hz TR 2.7 2.8 3.2 3.3 3.5 3.8 3.9 4.0 4.3 4.3 4.5 4.8 5.0 5.0 5.7 6.0 6.3 6.8 7.8 9.1 10.0 2.8 3.2 3.3 3.5 3.8 3.9 4.0 4.3 4.5 4.8 5.0 5.7 6.0 6.3 6.8 7.8 9.1 10.0 2.4 2.6 2.7 2.8 3.0 3.2 3.3 3.3 3.7 4.1 4.3 4.5 4.7 5.1 5.7 6.0 6.3 6.9 7.5 8.8 10.0
输入功率 kW 2.55 2.66 2.94 2.98 3.13 3.45 3.57 3.57 3.67 3.83 3.97 4.25 4.28 4.40 5.00 5.29 5.37 5.80 6.80 7.77 8.51 2.68 2.82 3.14 3.30 3.58 3.69 3.35 3.83 3.97 4.25 4.26 5.10 5.16 5.54 5.66 6.63 7.77 8.47 2.43 2.67 2.75 2.90 3.13 3.35 3.58 3.43 3.92 4.04 4.21 4.41 4.58 4.89 5.26 5.56 5.77 6.28 7.19 8.25 9.53
能效比 COP W/W EER Btu/h/W 3.08 10.5 3.14 10.7 3.14 10.7 3.26 11.1 3.26 11.1 3.17 10.8 3.23 11.0 3.23 11.0 3.37 11.5 3.34 11.4 3.37 11.5 3.37 11.5 3.40 11.6 3.37 11.5 3.37 11.5 3.37 11.5 3.43 11.7 3.43 11.7 3.39 11.6 3.43 11.7 11.7 3.42 2.96 10.1 3.14 10.7 2.90 9.9 2.90 9.9 3.02 10.3 3.02 10.3 3.31 11.3 3.17 10.8 3.17 10.8 3.17 10.8 3.25 11.1 3.08 10.5 3.26 11.1 3.26 11.1 3.28 11.2 3.26 11.1 3.23 11.0 3.23 11.0 2.93 10.0 2.82 9.62 2.79 9.51 2.93 10.0 2.82 9.62 2.76 9.41 2.85 9.72 2.93 10.00 2.76 9.41 2.99 10.22 3.05 10.42 3.02 10.32 3.02 10.31 3.11 10.61 3.21 10.96 3.21 11.0 3.22 11.0 3.25 11.1 3.11 10.6 3.16 10.8 3.11 10.6
R22
R407C
R410A
最大额定 电流 MCC 9.5 9.5 10.0 10.0 11.0 12.0 12.0 12.5 13.0 13.0 13.1 15.0 15.0 15.0 15.0 15.0 16.0 17.0 21.0 24.0 25.0 9.5 11.0 11.5 10.0 12.0 12.0 12.0 13.0 12.5 14.0 15.0 15.0 15.0 16.0 17.0 21.0 24.0 25.0 10.0 10.0 10.0 10.0 10.0 12.0 12.0 12.5 13.5 13.5 13.0 15.0 15.0 15.0 19.0 19.0 18.0 19.0 19.0 25.0 27.0
MAKING MODERN LIVING POSSIBLE
丹佛斯新型涡旋压缩机
50-60Hz R407C R22 R410A
REFRIGERATION & AIR CONDITIONING DIVISION
选型及应用指南
应用指南
目录
涡旋压缩机原理 涡旋压缩机部件 涡旋压缩过程 性能 压缩机命名 命名规则 铭牌 技术参数 50-Hz参数 60-Hz参数 尺寸 HRM032-034-038-040-042/HRP034-038-040-042/HRH029-031-032-034-036-038/ HRM-045-047/HRP-045-047/HRH039-040 HRM048-051-054-058-060/HLM068-072-075-078-081/HRP048-051-054-058-60/ HLP068-072-075-078-081/HRH041-044-049-051-054-056/HLH061-068/HLJ072-075-083 HCM/HCP094-109-120 HCJ090-105-120 电气连接 电机电压 接线方法 接线盒IP等级 堵转电流 最大持续电流 绕组阻值 电气连接 电容与继电器 内置电机保护 相序和反转保护 电压不平衡 许可和认证 许可和认证 承压设备认证(PED)97/23/EC 低电压认证73/23/EC,93/68/EC 内部空余容积 运行工况 制冷剂和润滑油 电机电源 压缩机环境温度 运行界限 R22,R407C和R410A类型T R22和R410A类型U 最高排气温度 高低压保护 系统设计建议 概述 管路设计 制冷剂最大充注量 曲轴箱加热器 4 4 5 5 6 6 6 7 7 8 9 9 9 10 10 11 12 13 13 13 14 14 14 14 14 15 15 15 15 16 16 16 16 16 17 17 18 18 18 18 19 19 20 21 21 21 22 24
订货信息与包装 包装 包装明细 R22单独包装 R22工业包装 R407C单独包装 R407C工业包装 R410A单独包装 R410A工业包装 附件 单相PSC接线方式的运行电容 单相CSR接线方式的启动电容与启动继电器 螺纹口适配器套件 螺纹口适配器 曲轴箱加热器 排气温度保护 润滑油 安装部件
31 31 31 32 33 34 35 36 37 38 38 38 38 38 39 39 39 39
Hale Waihona Puke 技术参数名义制冷量 W 7 850 8 350 9 240 9 710 10 190 10 940 11 500 11 510 12 390 12 800 13 390 14 340 14 570 14 820 16 880 17 840 18 430 19 890 23 060 26 690 29 130 7 940 8 840 9 110 9 580 10 810 11 130 11 100 12 120 12 570 13 470 13 860 15 700 16 810 18 040 18 600 21 590 25 070 27 370 7 120 7 530 7 670 8 500 8 820 9 250 10 200 10 050 10 830 12 110 12 860 13 340 13 830 15 210 16 880 17 840 18 600 20 420 22 320 26 100 29 610 Btu/h 26 790 28 490 31 520 33 120 34 770 37 310 39 250 39 270 42 280 43 690 45 680 48 930 49 720 50 580 57 580 60 870 62 880 67 880 78 670 91 070 99 390 27 080 30 150 31 080 32 680 36 890 37 980 37 880 41 370 42 880 45 970 47 280 53 560 57 350 61 550 63 470 73 660 85 550 93 400 24 310 25 710 26 170 29 000 30 110 31 560 34 810 34 300 36 940 41 320 43 890 45 510 47 200 51 880 57 610 60 900 63 490 69 690 76 190 89 090 101 080