幼儿园弱电系统设计说明(学前教育)

合集下载

幼儿园强弱电、给排水全套施工图

幼儿园强弱电、给排水全套施工图
楼梯{\C7大一班大二班卫生间器材室外走道一楼及操场插座布局方案图 1:120SCALE:二楼插座布置方案图 1:80SCALE:三楼插座布置方案图 1:80SCALE:四楼插座布置方案图 1:80SCALE:五楼插座布置方案图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

弱电综合管路系统设计方案

弱电综合管路系统设计方案

弱电综合管线系统设计说明一、概述弱电系统是现代建筑物内的综合系统工程,包括:建筑设备监控系统、综合布线系统、平安防范系统、卫星接收及电视系统、一卡通管理系统、公共广播系统等。

它和大楼内全部建筑物的机电设备诸如:变配电、空调、照明等设施有密切关系。

大楼弱电系统对建筑物来说是一个整体,每个弱电系统都有电缆管线,整个大楼遍布着弱电系统的电缆。

管路设计的目的是使这些电缆按确定的规律,合理有序地安置在大楼内的综合管路中。

弱电综合管路的工程设计,其内容包括和整个弱电系统相关的弱电预埋管、预留孔洞、弱电竖井、桥架、管路及系统的电源供应、接地、避雷、屏蔽和机房。

综合管路的设计和施工还牵涉到和其它管道(如暖通、给排水和强电)的关系,以及建筑功能的综合配管或调整,桥架敷设预埋等。

浙江电力生产调度大楼弱电系统应是特殊完善、先进的。

而规范、整齐、通畅的管路、桥架系统是弱电系统的综合功能充分发挥作用的关键。

尤其是项目前期阶段,须要对弱电系统的综合管路进行统一设计,在土建施工时,就需进行预埋工作,以保证弱电工程实施时各种管线均能敷设到位,同时不相互干扰、相互碰撞。

二、需求分析临海市公共租赁房智能化系统包括安防监控系统、可视对讲系统、一卡通停车场管理系统、通信语音系统、无线巡更系统、机房设备系统等。

综合管线系统必需满足大楼弱电各子系统管线需求。

三、设计依据临海市公租房二期智能化工程方案设计图纸JGJ/T16-92 《民用建筑电气设计规范》GBJ116-88《火灾自动报警系统设计规范》GB50067-97《汽车库、修车库、停车场设计防火规范》GB50045-95《高层民用建筑设计防火规范》GA/T75-94《平安防范工程程序和要求》GB50198-94《民用闭路监视电视系统工程技术规范》GY/T106-92《有线电视广播技术规范》GBJ120-88《工业企业共用天线电视系统设计规范》GBJ79-85《工业企业通信接地设计规范》CECS72:2001《建筑和建筑群综合布线工程设计规范》GB50041-96《锅炉房设计规范》GBKJ-90《通信系统机房设计》GB50174-93《电子计算机房设计规范》GB50200-94《有线电视系统工程技术规范》GB50057-94《建筑物防雷设计规范》BG12323-90《电视接收机确保和电缆支配系统兼容的技术要求》GYJ41-89《卫星广播电视地球站设计规范》GYJ41-86《有线广播录音、播音室声学设计规范和用户技术要求》GB/T50314-2000《智能建筑设计标准》GB/T50312-2000《建筑和建筑群综合布线系统工程验收规范》YDJ26-89《通信局(站)接地设计暂行技术规范》GBJT-471《智能建筑弱电工程设计施工图集》YD/T926.1-97《大楼通信综合布线系统总规范》四、综合管线系统设计1、总体规划1、弱电系统共用一个弱电桥架,出桥架后依据室内装修状况在吊顶内暗敷或墙内暗敷管;2、各子系统的接线箱均安装于弱电井或实体墙上;3、弱电系统桥架均接受热镀锌桥架,桥架厚度参照国家相关标准。

某学校弱电智能化系统设计方案

某学校弱电智能化系统设计方案

★★★★★★★★学校弱电系统规划方案书(详细规划)编制单位:★★★★★★有限公司编制时间:2016年8月目录第1章室内外弱电综合管道系统31.1综合管道系统概述31。

2室内综合管道系统31。

2.1设计原则31.2.2设计内容41.2.3设计要求61.3室外综合管道71.3。

1设计原则71.3.2总体设计思路71.3.3设计要求8第2章综合布线系统102。

1系统概述102.1。

1网络布线系统102.1。

2语音通讯布线系统112。

2用户需求分析122。

3系统设计目标、原则162。

4系统的组成182。

5数据网设计192.5.1工作区子系统设计192。

5。

2水平子系统设计192。

5.3垂直干线子系统设计192.5。

4设备间及管理子系统设计202。

5.5建筑群子系统设计202.6其他智能化系统综合布线设计202。

7用户设备与布线系统的连接20第3章网络系统建设223.1校园网需求分析与设计规划223.1。

1校园网设计需求223。

1.2网络建设规划及分析243.2网络方案总体设计273。

2.1主干网络技术选型283.2。

2核心网络方案设计283.2。

3汇聚交换机的建设293。

2.4接入交换机的建设303。

2.5主干网络可靠性考虑303。

2.6路由协议设计303.2.7无线接入设计313.2。

8网络管理333。

3安全性设计343。

3。

1本地主机系统的安全考虑353.3.2内部网安全控制353.4网络设计分析363。

4。

1可靠性设计363。

4。

2网络的安全性设计38第4章可视楼宇对讲系统424。

1设计思想424。

2项目基本概况424.3设计原则和标准424.3.1设计原则424.3.2设计系统设计依据和标准434。

3。

3系统要求444。

4本校区楼宇对讲系统设计444。

5系统组成444.5。

1系统组成444.5.2系统主设备明细表454.5。

3系统设备介绍和选型454。

6工程用线51第5章校园安全防范系统525。

幼儿园弱电系统设计方案

幼儿园弱电系统设计方案

幼儿园弱电系统设计方案一、引言弱电系统在幼儿园建设中具有重要作用。

幼儿园是儿童教育的重要场所,弱电系统的设计要求能够满足儿童学习、生活、安全等方面的需求。

本文将着重从网络系统、安全监控系统、传声系统和电视系统等方面进行设计方案的介绍。

二、网络系统设计1.布线规划:为了满足幼儿园宽带网络需求,建议采用类似于星型拓扑结构的布线方式,确保网络信号传输的稳定性和可靠性。

2.网络安全:考虑到幼儿园网络的安全性,设计方案应包括网络防火墙、入侵检测等系统,以保护幼儿园网络免受外部威胁。

3.无线网络覆盖:为了方便教师和学生在教学楼内使用移动设备,设计方案应考虑到无线网络的覆盖范围和信号强度,确保网络信号的稳定性。

三、安全监控系统设计1.摄像监控:设计方案中应考虑到幼儿园建筑内外的安全监控点位,包括教室、走廊、门口等位置,以确保对幼儿园内外安全情况的监控。

2.报警系统:设计方案应包括火灾报警、紧急求救报警等功能,以保证幼儿园发生紧急情况时及时报警、反应。

3.出入口控制系统:应考虑到幼儿园出入口的智能化管理,设计方案中可以采用刷卡门禁、人脸识别等方式,提高门禁系统的安全性和智能化水平。

四、传声系统设计1.广播系统:设计方案中应包括广播系统,以满足教职工和学生的广播需求。

2.教室传声系统:根据教室大小和布局,设计方案中应将传声器安装在合适位置,确保教师的语音能够清晰传达给学生。

3.室外传声系统:幼儿园室外环境复杂多变,设计方案应兼顾传声器的防水、耐用等特点,以保证音响效果。

五、电视系统设计1.幼儿教育资源:设计方案中应包括电视系统,以便观看相关的教育视频、儿童动画等资源,丰富幼儿园教学内容。

2.安全与便捷:设计方案应选用壁挂式电视,并充分考虑到电视的高度、固定等因素,以保证儿童的安全和便捷性。

3.互动性:设计方案可以考虑添加电视触摸屏等互动设备,以提升儿童学习的趣味性和参与性。

六、总结教育是幼儿园的首要任务,而弱电系统是支撑教育的重要基础设施。

幼儿园弱电工程方案

幼儿园弱电工程方案

幼儿园弱电工程方案一、前言随着现代科技的发展,信息化已经深入到了各行各业,而幼儿园作为教育机构也不例外。

为了提高幼儿园的管理效率、教育质量和安全防范能力,必须进行弱电工程的设计和建设,以满足现代幼儿园对信息技术设施的需求。

二、方案目标本方案的目标是为幼儿园提供一整套可靠的弱电系统工程方案,包括网络系统、安防系统、通讯系统等,以满足幼儿园日常教学、管理和安全防范的需求,提高工作效率,提升教学质量。

三、网络系统设计1. 网络架构:采用星型拓扑结构的局域网(LAN),通过交换机与各部门连接,便于管理和维护。

2. 无线网络覆盖:在幼儿园内部建立无线局域网(WLAN),覆盖整个院内,便于教师和学生使用移动设备进行教学和学习。

3. 网络设备:选择品牌优良、性能稳定的路由器、交换机、无线接入点等设备,确保网络连接稳定可靠。

4. 网络安全:配置防火墙、入侵检测系统(IPS)等安全设备,保障网络的安全性,防范病毒、黑客攻击等安全威胁。

5. 信息化平台:建立幼儿园的信息化管理平台,包括教务管理系统、家长通讯系统、学生档案管理系统等,以提高管理效率和服务质量。

四、安防系统设计1. 视频监控系统:在幼儿园内部设置摄像头,对主要场所进行监控,保障幼儿园的安全。

2. 门禁系统:设置门禁设备,在幼儿园的出入口和重要区域进行控制,保证安全管理。

3. 报警系统:安装火灾报警器、气体报警器等设备,及时发现安全隐患,保护师生的生命财产安全。

4. 防盗系统:配置门窗传感器、红外探测器等设备,防范盗窃和入侵事件。

五、通讯系统设计1. 电话系统:建立固定电话系统和室内分机,方便园内各部门之间的通讯。

2. 对讲系统:安装对讲设备,方便教师间的通讯,提高教学效率。

3. 紧急广播系统:设置紧急广播设备,用于发布紧急通知和应急处理指令。

六、工程实施计划1. 工程前期:进行场地勘察,确定弱电工程的布线和设备安装位置。

2. 设备选型:根据实际需求,选择适合的网络设备、安防设备和通讯设备。

幼儿弱电工程设计方案

幼儿弱电工程设计方案

幼儿弱电工程设计方案一、项目概述幼儿园是孩子们接受教育的重要场所,而弱电工程是幼儿园建设中不可或缺的一部分。

弱电工程是指在建筑物内部对信息传输、控制、监控等进行传输、处理和管理的系统,主要包括通信网络、安防监控系统、智能化教学设备等。

因此,设计合理的弱电工程对于幼儿园的健康发展和孩子们的安全教育至关重要。

二、设计原则1.科学性原则根据幼儿园的实际情况,合理配置弱电设备,使其满足幼儿园的日常运行需求。

2.安全性原则弱电工程设计应符合国家弱电工程相关标准,确保设备的可靠性和安全性。

3.灵活性原则为了适应未来幼儿园的发展需求,弱电工程设计应具备一定的扩展性和灵活性。

三、设计内容1.通信网络幼儿园内部的通信网络是幼儿园弱电工程中的重要组成部分。

网络设备应具备高速、稳定、安全、可靠的特点,能够满足师生之间、师生与家长之间的信息传输需求。

此外,应考虑到在教学过程中可能会使用到的多媒体教学设备,因此需要为网络设备提供足够的带宽和稳定性。

2.安防监控系统幼儿园内安全是第一要务,安防监控系统是保障幼儿园安全的关键。

安防监控系统应包括监控摄像头、门禁系统、报警系统等设备,能够实现全方位、全天候的监控。

同时,应设置的门禁系统能够确保外来人员无法无故进入幼儿园,报警系统则可以及时发现异常情况并进行预警和处理。

3.智能化教学设备随着时代的不断发展,幼儿园教学手段也逐渐向智能化发展。

智能化教学设备应包括智能白板、投影仪、音响系统等设备,能够为幼儿园教师在教学过程中提供更多的教学资源和工具。

四、设计流程1.调研阶段设计团队首先需要对幼儿园的实际情况进行详细的调研,了解幼儿园的规模、布局、未来发展规划等信息,从而为设计提供基础数据。

2.方案设计阶段根据调研阶段的数据,设计团队应综合考虑通信网络、安防监控系统、智能化教学设备等方面的需求,提出合理的弱电工程方案。

3.施工阶段设计通过评审后,施工团队按照设计方案开始施工,确保弱电设备的安装、调试和运行。

弱电智能化系统工程设计说明

弱电智能化系统工程设计说明

智能化系统工程设计说明一、设计范围1、智能化专网系统2、视频安防监控系统3、楼宇可视对讲系统4、出入口门禁控制系统5、电子巡更系统6、停车场管理系统7、背景音乐系统8、多媒体信息发布系统9、保安无线对讲系统10、无线WIFI系统11、POS系统12、酒店自助系统13、电梯梯控系统14、智能照明系统15、能耗计量系统16、车位引导系统17、建筑设备监控系统19、联网型温控器系统20、客流统计摄系统21、机房工程与防雷及接地系统二、系统说明与配置1、智能建筑专网系统本系统仅服务于智能化系统,是智能化系统的基础承载网络,具体承载的智能化系统有视频安防监控系统、楼宇可视对讲系统、门禁控制系统、停车场管理系统、背景音乐系统等。

根据项目需求,本次设计采用核心层、汇聚层、接入层三层网络构架,中心机房设置于消防控制室,系统建成后需由运营商接入宽带网光纤,具体带宽根据实际网络流量,后期由弱电承包商及物业公司确定。

智能建筑专网系统要求具备较强的稳定性、扩展性,系统采用企业级网络设备。

智能建筑专网内的每个智能化系统划分一个VLAN进行管理,水平采用UTP CAT5e网线,接入交换机到汇聚交换机使用UTP CAT6网线,主干采用单模光纤进行传输。

2、视频安防监控系统采用数字型视频安防监控系统,基于智能建筑专网系统建设。

采用1080P 高清红外网络摄像机,高空抛物摄像机500W像素,录像时间2个月,对主要通道、重要区域、建筑物出入口(人行/车行)、车库及电梯轿厢进行监控。

按当地公安要求在小区出入口安装高清摄像机(500万彩色转黑白摄像机),配云硬盘NVR,视频信号上传公安指定机构;a.室外主要出入口及主要干道设置枪型摄像机;b.地下室车库车道设置枪型摄像机;c.各栋楼电梯厅、大堂、公共走道等重要区域设置半球摄像机;d.各栋楼电梯轿厢设置电梯专用摄像机;e.裙楼商业采用枪型摄像机和半球摄像机。

f.总平采用枪型摄像机,重要路口采用球型摄像机。

幼儿园电气设计

幼儿园电气设计

幼儿园电气设计建筑供配电课程设计专业:建筑电气班级: 13-01姓名:刘生福学号: 541201040127课题:某小区幼儿园电气设计指导教师:曹祥红2021年1月20日某小区幼儿园电气设计研究摘要本次设计是针对本次卒业设计针对某小区幼儿园的照明、弱电、防雷接地、CATV和综合布线(德律风和收集)进行设计,本建筑包含一二层两部分,一二层分别设有活动室、办公室、卧房等;一层别的设有厨房、消毒间、配菜间等。

本人负责整栋楼的照明体系设计、防雷接地设计以及弱电体系设计。

依照负荷等级的划分,体系为三级负荷;防雷等级为三类防雷,只需防侧击雷;综合布线体系为加强型。

设计重要内容包含负荷运算、照度运算、灯具选择、灯具安排、照明操纵、照度验算、照明配电;建筑防雷、接地体系;有线插座安排,分派器、分支器选择,有线电视线缆的选择,敷设方法的选择,有线电视旌旗灯号前端设备;语音插座、信息插座安排,电缆传输体系设计,收集交换机等。

关键词:照度运算,负荷运算,防雷,接地,电缆电视,综合布线体系目次1 、引言 (4)2、设计部分 (4)2.1设计内容 (4)2.2设计步调 (4)2.3设计依照规范 (5)2.4设计概述 (5)2.4.1 建筑物概况 (5)2.4.2 电力负荷等级 (6)2.4.3 接地防雷 (6)2.4.4 电缆电视体系和综合布线体系 (6)2.5照明电气设计 (7)2.5.1照明电气设计义务 (7)2.5.2照明灯具的选择和安排 (7)2.5.3照度运算验证及插座的选择和安排 (9)2.5.4 照明供电体系 (13)2.5.5 照明负荷运算 (14)2.5.6 导线、电缆的选择与敷设 (16)2.5.7 断路器及漏电爱护的选择 (19)2.5.8 应急照明设计 (20)2.5.9 应急照明线路的敷设和配电爱护 (21)2.6防雷接地设计 (22)2.6.1防雷设计 (22)2.6.2接地爱护 (23)2.6.3电气设备接地 (24)2.7有线电视体系设计 (25)2.7.1节目源 (25)2.7.2体系总体筹划 (26)2.7.3传输分派体系的设计 (26)2.8综合布线体系设计 (29)2.8.1综合布线体系的设计原则 (29)2.8.2综合布线体系总体设计筹划 (30)2.8.3综合布线体系设计等级 (31)2.8.4综合布线各子体系的设计 (31)3、设计小结 (37)4、申谢 (38)参考文献 (39)附录 (40)1 、引言人类社会进入了21世纪的信息时代,纯确实一栋没有供配电的大年夜楼对人们来说差不多没有多大年夜的意义,只有给建筑配以合理的电气体系人们才能进行正常的日常生活。

三层幼儿园强弱电全套电气施工图,含说明

三层幼儿园强弱电全套电气施工图,含说明
书房卫生间洗手间更衣室洗簌间卫生间2990.2766下客厅卧室三层照明平面图活动室活动室卫生间更衣室洗手间更衣室卫生间洗手间卫生间客厅洗簌间屋面活动平台2%2%1%上下2%2%2%2%2%2%1%1%1%2%寝 室寝 室更衣室活动室活动室卫生间洗手间1:100暖 通暖 通园长办公室三层教师办公室资料室书房卧室1%电水日 期签 名工 种2%2%1%1%二层照明平面图寝 室活动室更衣室更衣室洗手间卫生间卫生间洗手间洗手间更衣室卫生间活动室寝 室活动室活动室卫生间洗手间更衣室上下1:100电水签 名工 种一层教师办公室二层教师办公室卫生间日 期上下音体活动室寝 室更衣室更衣室寝 室活动室活动室卫生间卫生间洗手间洗手间寝 室活动室一层照明平面图1:100主食加工间粗加工洗澡间卫生间备餐间洗碗消毒间休息室主食库付食库上2%2%2%2%1%2%暖 通工 种签 名日 期水电仓库药品试剂室防菌室晨检室输液室更衣室洗手间卫生间隔离室医务室卫生间消毒室M3上音乐舞蹈室35052550050052552524005001500500150052524005252400525345052000250036003600360036002500330036003450345025003450345034502500360074001200300520003600360036002002400280036002003200740021002003600360036002500400400240010002800200060006000360025002320036007400360024005200052000360035010020017518002950150020020021001753600360033002500360035035034503450250025003450292534502400345024002

三层幼儿园电气设计施工图16张(含设计说明)

三层幼儿园电气设计施工图16张(含设计说明)
1231F层照明1F层电气设计说明竖向配电幼儿园OK其余0.184#线0.55#线0.101:1003#线0.308#线0.05打图设置地下接地4电施-1电气设计说明电施-3电施-2图 号备 注标准图集或重复使用图图号电气图集共 1 页图幅工程项目图 名一层电气平面图一层照明平面图A1A1A1低压配电系统图电施-4地下接地平面图弱电系统图A12F层照明2F层电气56屋面防雷电施-5电施-6二层电气平面图二层照明平面图屋面防雷平面图一层弱电平面图二层弱电平面图A1A186系列~/250V10A距地1.800m带安全门三极加二极插座安装高度距地1.500m备注箱门带锁进户配电箱照明配电箱符号序号42311名称向上配线漏电保护器28291117151613141220断路器25272624222321181991087611530备注电气工程图例序号名称符号安装高度 \fSimHei|b0|i0|c134|p22相线的截面积S(mm )2保护导体的最小截面积S (mm )保护导体的最小截面积S (mm )相线的截面积S(mm )22SS<1616<S<351635<S<400S/2400<S<800S>800S/4200距地0.500m总等电位联结箱顶板内敷设线路地板内、墙内敷设线路照明平面图中照明平面图中照明,容量为165.3KW。}\P 2. 工程电源:\P 依据甲方提供资料和经供电部门批准。从校园变电亭采用电力电缆埋地引入~380/220V电源。\P 3. 计费:\P 依据当地供电管理部门规定,在校园变电亭设表计量。\P 4. 供电方式:\P 本工程采用放射式和树干式相结合的供电方式。\P 5 光源及节能:\P 荧光灯、吸顶灯等选用高效节能型灯具。荧光灯均配高效节能L级电子镇流器,COSφ>0.96。直管荧光灯选用高效T8三基色系列。装饰用灯具需

弱电施工图纸设计说明

弱电施工图纸设计说明

弱电施工图纸设计说明一、工程概述本弱电施工图纸设计旨在为具体项目名称提供全面、可靠且高效的弱电系统解决方案。

该项目位于项目地点,总建筑面积为建筑面积平方米,涵盖了建筑功能,如办公、住宅、商业等多种用途。

二、设计依据1、国家及地方现行的有关设计规范、规程及标准,如《智能建筑设计标准》(GB 50314-2015)、《综合布线系统工程设计规范》(GB 50311-2016)等。

2、建设单位提供的设计任务书及相关要求。

3、建筑、结构、给排水、电气等相关专业提供的设计图纸和资料。

三、设计范围本次弱电系统设计包括以下子系统:1、综合布线系统2、计算机网络系统3、安全防范系统(包括视频监控系统、入侵报警系统、门禁管理系统等)4、有线电视系统5、背景音乐及紧急广播系统6、多媒体会议系统7、机房工程四、综合布线系统1、系统概述综合布线系统是整个弱电系统的基础,为各类信息的传输提供高速、稳定的通道。

2、工作区子系统根据不同的使用功能,在工作区设置相应的信息插座,包括语音插座和数据插座。

插座采用符合标准的 RJ45 模块,安装高度距地面具体高度。

3、水平子系统水平线缆采用六类非屏蔽双绞线,满足语音、数据及图像等信号的传输要求。

线缆沿金属线槽或 PVC 管敷设至各工作区。

4、垂直子系统垂直干线采用大对数电缆和光纤,分别用于语音和数据的传输。

电缆和光纤敷设在弱电竖井内的桥架中。

5、管理子系统在每层的弱电间设置配线架,对水平线缆和垂直干线进行管理和连接。

6、设备间子系统设备间位于具体位置,安装有网络设备、服务器等核心设备。

五、计算机网络系统1、系统架构采用核心层、汇聚层和接入层的三层网络架构,确保网络的稳定性和可扩展性。

2、核心层核心交换机具备高速转发能力和强大的路由功能,负责整个网络的数据交换。

3、汇聚层汇聚交换机连接多个接入层交换机,对数据进行汇聚和处理。

4、接入层接入层交换机为终端设备提供网络接入,实现用户与网络的连接。

教育建筑学校建筑弱电方案设计说明

教育建筑学校建筑弱电方案设计说明

教育建筑学校弱电方案设计说明弱电设计1、设计目标本工程弱电系统设计分为如下:1).综合布线系统;2).计算机网络系统;3).安全防范系统、门禁系统;4).汽车进出道闸系统;5).无线巡更系统;6).电子围栏;7).校园广播系统;8).多媒体系统;9)、食堂POS机消费系统;10)、公共显示系统、机房工程、管线工程等;2、设计依据有关国家现行规范、标准:1).《智能建筑设计标准》 GB50314-2015 2).《综合布线系统工程设计规范》 GB/50311-2016 3).《综合布线系统工程验收规范》 GB/50312-20164).《民用闭路监视电视系统工程技术规范》 GB/50198-2011 5).《电子计算机机房设计规范》 GB/50174-2008 6).《安全防范工程技术规范》 GB50348-2004 7).《入侵报警系统技术要求》 GA/T368-2001 8).《视频安防监控系统技术要求》 GA/T367-2001 9).《安全防范系统通用图形符号》 GA/T74-2000 10).《报警图像信号有线传输装置》 GB/T16677-1996 11).《民用建筑电气设计规范》 JGJ16-2008 12).《建筑物电子信息系统防雷技术规范》 GB50343-2012 13).《公共广播系统工程技术规范》 GB50526-2010 14).《安全技术防范系统建设技术规范》 DB33/T 768.10-200915).《智能建筑工程质量验收规范》GB 50339-201316).《建筑电气工程施工质量验收规范》GB 50303-201117).《安全防范报警设备安全要求和实验方法》GB 16796-200918).《入侵报警系统工程设计规范》GB 50394-20073、各子系统设计说明1)综合布线系统综合布线系统使语音和数据通讯设备、交换设备和其它信息管理系统彼此相连,又使这些设备与外部通讯网络相连接。

某小区幼儿园电气设计毕业设计

某小区幼儿园电气设计毕业设计

毕业设计 (论文)专业:电气工程及其自动化班级:姓名:学号:课题:某小区幼儿园电气设计指导教师:某小区幼儿园电气设计研究机电系电气工程及其自动化专业指导教师:本次设计是针对本次毕业设计针对某小区幼儿园的照明、弱电、防雷接地、CATV和综合布线(电话和网络)进行设计,本建筑包括一二层两部分,一二层分别设有活动室、办公室、卧室等;一层另外设有厨房、消毒间、配菜间等。

本人负责整栋楼的照明系统设计、防雷接地设计以及弱电系统设计。

根据负荷等级的划分,系统为三级负荷;防雷等级为三类防雷,只需防侧击雷;综合布线系统为增强型。

设计主要内容包括负荷计算、照度计算、灯具选择、灯具布置、照明控制、照度验算、照明配电;建筑防雷、接地系统;有线插座布置,分配器、分支器选择,有线电视线缆的选择,敷设方式的选择,有线电视信号前端设备;语音插座、信息插座布置,电缆传输系统设计,网络交换机等。

关键词:照度计算,负荷计算,防雷,接地,电缆电视,综合布线系统AbstractThe design is for a training of cadres for the floor and weak power distribution system design, which includes one two-story main building . It incloud two part :one and two floor main have activity house,office,bedroom and so on.Besides,one floor is equipped with kitchen, ware washing and sterilizing room, and food running room .I am responsible for the entire floor of the lighting system design, mine design and weak grounding system design. According to the delineation of class load, the three-tier system for the load; mine for three categories of grading mine, just mine-ceji; integrated wiring system for enhanced. Design elements include the main illumination, the load, the cable selection, choice of cable television distributor branch, the integrated wiring systems design, calculation of the length of cable.Key words:illumination, the load calculation, mine, grounding, cable television, integrated wiring system目录1 、引言 (5)2、设计部分 (5)2.1设计内容 (5)2.2设计步骤 (5)2.3设计依据规范 (6)2.4设计概述 (6)2.4.1 建筑物概况 (6)2.4.2 电力负荷等级 (7)2.4.3 接地防雷 (7)2.4.4 电缆电视系统和综合布线系统 (7)2.5照明电气设计 (8)2.5.1照明电气设计任务 (8)2.5.2照明灯具的选择和布置 (8)2.5.3照度计算验证及插座的选择和布置 (10)2.5.4 照明供电系统 (14)2.5.5 照明负荷计算 (15)2.5.6 导线、电缆的选择与敷设 (17)2.5.7 断路器及漏电保护的选择 (19)2.5.8 应急照明设计 (20)2.5.9 应急照明线路的敷设和配电保护 (22)2.6防雷接地设计 (23)2.6.1防雷设计 (23)2.6.2接地保护 (24)2.6.3电气设备接地 (25)2.7有线电视系统设计 (25)2.7.1节目源 (25)2.7.2系统总体规划 (26)2.7.3传输分配系统的设计 (26)2.8综合布线系统设计 (29)2.8.1综合布线系统的设计原则 (29)2.8.2综合布线系统总体设计方案 (30)2.8.3综合布线系统设计等级 (31)2.8.4综合布线各子系统的设计 (31)3、设计小结 (37)4、致谢 (38)参考文献 (39)附录 (40)1、英文原文 (40)2、中文翻译 (47)1 、引言人类社会进入了21世纪的信息时代,单纯的一栋没有供配电的大楼对人们来说已经没有多大的意义,只有给建筑配以合理的电气系统人们才能进行正常的日常生活。

幼儿园弱电施工方案范本

幼儿园弱电施工方案范本

幼儿园弱电施工方案范本1. 引言本文档旨在为幼儿园弱电施工方案提供一个范本,包括对幼儿园弱电系统结构、设备配置、布线方案以及测试与调试等方面的详细说明。

幼儿园作为教育机构,弱电系统在其中起到了重要的作用,无论是教学手段的更新换代还是安全保障,弱电系统都扮演着非常关键的角色。

因此,在幼儿园的弱电施工中,需要有一个合理的方案来确保系统的正常运行和高效使用。

2. 系统结构幼儿园的弱电系统主要包括以下几个部分:•数据通信系统:用于实现幼儿园内部的数据传输和网络连接。

•视听系统:用于提供音频和视频的播放设备,包括幼儿园内部音视频的播放以及与外部的音视频传输。

•安防系统:用于监控幼儿园内部的安全状况,包括视频监控、门禁系统等设备。

•智能化系统:用于提供智能化控制,包括灯光控制、温度控制、智能化安全控制等。

在设计系统结构时,需要根据幼儿园的具体情况和需求,进行合理的选择和布局。

3. 设备配置3.1 数据通信设备数据通信设备是幼儿园弱电系统的基础设备,包括交换机、路由器、终端设备等。

在幼儿园的规划中,需要根据需求选择合适的设备,并进行合理的配置和布局。

3.2 视听设备视听设备包括投影仪、幼儿园内部音箱、摄像头等设备。

这些设备需要根据教学和娱乐需求进行选择和配置。

例如,教学用的投影仪需要具备高分辨率和适合教学的功能,音箱需要具备良好的音质和适合教学的特性。

3.3 安防设备安防设备是保障幼儿园安全的重要组成部分,包括视频监控设备、门禁系统等。

在幼儿园的规划中,需要根据建筑布局和安全需求进行合理的设备选择和布局。

3.4 智能化设备智能化设备主要用于提供智能化控制,包括灯光控制、温度控制、智能化安全控制等。

在选择设备时,需要考虑系统的稳定性和可靠性,以及与其他设备的兼容性。

4. 布线方案弱电系统的布线方案对于系统的稳定性和使用效果至关重要。

在幼儿园的布线中,需要遵循以下原则:•电缆类型选择:根据数据传输的距离和速率要求,选择适当的电缆类型,例如CAT6、光纤等。

(完整版)弱电系统制图规范和标准

(完整版)弱电系统制图规范和标准

弱电系统制图规范和标准一、图框、比例1、制图图框根据图纸大小确定图框大小。

建筑面积及设计图纸比例在图下规定内时,图框与纸型选择如下:(1-1图)2、规划设计建筑图及建筑面积超过5000m2时,采用A0纸型及设计图框。

(1-2图)4、设计总说明、各专业系统图统一使用A3图框,图纸目录或专业区分时统一采用A4图框。

5、图框根据图纸比例或要求,图框缩放以比例大小缩放。

(1-3图)工程设计图纸幅面和图框大小应符合国家标准GB6988.2-86《电气制图一般规则》的规定,一般宜采用A0、A1、A2、A3、A4加长的图纸幅面。

在保证图面布局紧凑和使用方便的情况下,应选择合适的图纸幅面,使图纸大小适中,与表述对象的规模大小、复杂程度相称。

二、图线(2-1图)2、由甲方提供或设计所提供的图纸,根据需要提出相应的建筑框架,框架颜色统一更改为9号或7号(白色)颜色,其余不需要的图层一律删除。

3、设置时,统一采用粗线、中粗线和细线的宽度比率为4:2:1的制图方式。

4、同一张图纸当中设计的线形分为实线、虚线、点划线线及双点划线,一般用图如下:(2-2图)工程设计图中通常只选用两种宽度的图线,粗线宽度为细线宽度的两倍。

对复杂的图也可采用粗、中、细三种线宽,线的宽度按2的倍数依次递增。

图线宽度一般从以下系列中选用:0.25、0.35、0.5、0.7、1.0、1.4毫米。

当需要区分新旧内容时,粗线表示新建、细线表示原有设施、虚线表示规划预留部分。

三、图例、文字说明1、图例根据设计文本及图例集的要求设计各专业点线图;2、图例说明的图框宽度与会签栏的高度比例为2:1的方式制作;3、工程设计图中的文字等应排列整齐、间隔均匀。

其书写位置应根据图面妥善安排,文字多时宜放在图的下面或右侧。

(3-1图)5、图纸设计过程中,如下列情况必须添加索引线说明:1) 敷设管、桥架的规格大小时;2) 当管线穿墙时,注明穿墙空洞;3) 当楼层线缆越层时,注明方向并制作相应的箭头标明上引或下引;4) 当管、或桥架内部敷设多条或多种线缆时,注明线缆数量或规格;5) 当制作细部或安装大样图纸时,注明各各部位的材料名称;6、索引注明文字大小与设计说明文字大小统一,索引线箭头及文字根据标注的大小统一,索引采用箭头及小点为准。

数层幼儿园电气工程布置图

数层幼儿园电气工程布置图
音体活动室食品加工厨房配餐间消毒间洗衣间医务室AC教师办公室门厅晨检室隔离室活动室教师办公室财务室园长办公室教具室办公室办公室办公室寝室1:20卫生间衣帽间教师办公室会议室图书室主副食库男卫女卫男卫女卫办公室音体活动室食品加工厨房配餐间消毒间洗衣间医务室教师办公室门厅晨检室隔离室活动室教师办公室财务室园长办公室教具室办公室办公室办公室寝室1:20卫生间衣帽间教师办公室会议室图书室主副食库男卫女卫男卫女卫办公室音体活动室AC食品加工厨房配餐间消毒间洗衣间医务室1:12AC教师办公室门厅晨检室隔离室活动室教师办公室财务室园长办公室教具室办公室办公室办公室寝室1:20卫生间衣帽间教师办公室会议室图书室主副食库男卫女卫男卫女卫办公室SDXAPCF注:厨房仅预留动力配电箱,详细见后期装修。1AL1GGKKGGXXX2AL1GGGGGKKKKG3ALGGGGGGUV紫外线灯UVUVUVUVUV紫外线灯UVUVUV2AL13AL1自 控工 艺通 讯结 构建 筑电 气给 排 水暖 通04版权所有 盖章有效 All rights reserved,valid only after sealed施工图14-XY-019电气日期比例图号专业建筑工程 乙级 证书编号:A241016123执业签章SEAL STAMP FOR RELEASE出图签章Date日 期修 改 内 容Revise Description序 号Order No.、承建商必须实地复核所有尺寸。PLANNING DESIGN CO., LTD.1、本图纸所有权属河南圣杰建筑规划设计有限公司。SITE BY THE CONTRACTOR.ALL MEASUREMENTS MUST BE CHECKED AT THE NOTE:PROPERTY OF HENAN SHENGJIE ARCHITECTURE ALL DESIGNS,DRAWINGS &am

弱电设计说明完整版

弱电设计说明完整版

弱电设计说明一、设计依据1)《智能建筑设计标准》GB/T50314-20002)《民用闭路监视电视系统工程技术规范》GB 50198-943)《安全防范工程技术规范》GB 50348-20044)《建筑与建筑群综合布线系统工程设计规范》GB/T50311-20005)《建筑与建筑群综合布线系统工程验收规范》GB/T50312-20006)《建筑智能化系统设计技术规程》DBJ01-615-20037)《建筑物电子信息系统防雷技术规范》GB50343-20048)《民用建筑电气设计规范》JGJ/T16-92;9)《高层民用建筑防火规范》GB50045-95;(2005年版)10)《人民防空工程设计防火规范》GB50098-98;11)《人民防空地下室设计规范》GB50038-2005;12)《电子计算机房技术规范》GB50174-913)《有线电视系统工程技术规范》GB50200-94;14)业主提供的设计资料及要求;15)相关专业提供的设计资料;二、设计范围楼宇自控系统、综合安防系统、综合布线系统、有线电视系统、会议系统、排队叫号系统、大屏幕显示系统、触摸查询系统、弱电系统接地三、楼宇自控系统1、系统设计1) 整个建筑的楼宇自控系统(BAS)为完整的分布式集散控制系统,采用标准化局域网技术和开放型现场总线对与现场多种设备,多个子系统实施集中监控、联动和管理,对不同工作站及现场控制器的控制权限的设定由网络服务器完成;2)系统采用浏缆器/服务器(B/S)的模式(可为日后增加用户且不增加费用预备条件,以利于系统扩展)。

3)管理层网络采用TCP/IP标准通讯协议。

4)现场层采用开放型LON或RS485总线或其他工业标准总线形式。

5)系统电源采用集中与分散相结合方式供电,各子系统设置UPS不间断电源,并能保证持续工作不小于1小时;6)BA系统的方案和设备的选择考虑“向上支持、向下兼容”的原则2、系统要求1)保证大厦生活和工作环境的舒适性;2)确保建筑物及内部人员的安全和灾害抵御能力,提供保证生命、财产、建筑物安全的必要措施;3)提供最佳的系统控制及节能措施和优化运行方案,以实现合理的能源管理,降低运行费用;4)实现物业管理自动化。

中心幼儿园弱电初步设计方案

中心幼儿园弱电初步设计方案

中心幼儿园弱电初步设计方案苏州浒墅关中心幼儿园智能化工程初步方案设计目录系统总体规划 (3)1、项目概述 (3)2、设计依据 (4)3、智能化系统总体目标 (6)4、系统设计定位 (7)5、系统设计原则 (9)5.1 高度的安全性、可靠性 (9)5.2 整体规划、分步实施 (10)5.3 先进性与实用性兼顾 (10)第一章综合布线系统 (10)1.1系统概述 (10)1.2系统设计 (12)1.2.1 校园综合布线总体设计 (13)1.2.2 建筑综合布线设计说明 (14)1.3系统产品选型 (18)1.3.1 工作区子系统 (18)1.3.2 水平布线子系统 (20)1.3.3 垂直干线子系统 (20)1.3.4 楼层管理子系统 (21)1.3.5 设备间子系统 (23)第二章计算机网络及服务器系统 (24)2.1网络建设目标及需求分析 (24)2.1.1网络建设目标 (24)2.1.2 网络建设需求分析 (26)2.2网络建设设计目标及设计原则 (30)2.2.1实用性和经济性 (31)2.2.2先进性和成熟性 (31)2.2.3可靠性和稳定性 (31)2.2.4 安全性和保密性 (32)2.2.5可扩展性和可管理性 (32)2.2.6结构化设计 (33)2.3校园网络建设方案 (33)2.3.1网络拓扑 (33)2.3.2方案设计 (34)2.4校园网安全规划 (35)2.4.1设备访问控制安全 (35)2.4.2地址转换(NAT) (36)2.4.3 安全绑定 (36)2.4.4 无线管理 (36)2.5IP地址规划 (37)2.5.2 校园网IP地址具体规划 (38)2.6设备选型 (40)2.6.1 多核安全网关 (40)第三章校园公共广播与背景音乐系统 (44)3.1系统概述 (44)3.2系统需求 (45)3.3系统设计 (46)3.4系统功能 (48)3.5工程设备说明 (55)第四章安全防范系统 (68)4.1视频监控系统 (71)4.1.1 系统概述 (71)4.1.2 系统功能 (72)4.1.3 系统设计 (73)4.1.4系统设备选型 (75)4.2入侵报警系统 (88)4.2.1 系统概述 (88)4.2.2 系统规划 (89)4.2.3 设备参数 (91)4.3电子巡更系统 (92)4.3.1概述 (92)4.3.2系统组成 (92)4.3.3系统工作流程 (94)4.3.4系统特点 (95)4.3.5 系统功能 (96)4.4电子围栏系统 (96)4.4.1概述 (96)4.4.2系统传输及防雷 (98)4.4.3系统工作原理、功能 (99)4.4.4安装要求及注意事项 (100)4.5门禁管理系统 (101)4.5.1 系统组成 (101)4.5.2 系统结构示意图 (101)4.5.3系统功能特点 (101)第五章机房建设子系统 (103)5.1系统概述 (103)5.2需求分析 (103)5.3设计原则及标准规范 (103)5.3.1 设计原则 (103)5.3.2 设计标准及规范 (104)5.4设计内容 (106)5.4.2 机房配电 (107)5.4.3防雷击过电压及浪涌措施 (108)第六章综合管路系统 (113)6.1电缆桥架安装 (113)6.1.1 设备材料 (114)6.1.2 电缆桥架安装 (114)6.2室内管道 (115)6.3室外管线系统 (116)6.3.1 系统概述 (116)6.3.2 管线设计 (116)附件 (122)系统总体规划1、项目概述浒墅关镇中心幼儿园位于桑苑路东、苏通路南、苏浒路西、通浒路北.。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

幼儿园弱电初步设计说明一、设计依据二、设计范围三、本设计包括以下内容:网络电话布线系统有线电视系统自办节目播出系统视频监控系统防盗报警系统公共广播系统多媒体会议系统门禁管理系统考勤管理系统幼儿园接送系统交互式智能白板显示屏电子巡更系统防雷接地系统不间断电源一、网络电话布线系统计算机网络系统就是利用通信设备和线路将地理位置不同、功能独立的多个计算机系统互联起来,以功能完善的网络软件实现网络中资源共享和信息传递的系统。

通过计算机的互联,实现计算机之间的通信,从而实现计算机系统之间的信息、软件和设备资源的共享以及协同工作等功能,其本质特征在于提供计算机之间的各类资源的高度共享,实现便捷地交流信息和交换思想。

功能特点:计算机网络系统是由网络硬件和网络软件组成的。

在网络系统中,硬件的选择对网络起着决定的作用,而网络软件则是挖掘网络潜力的工具。

①计算机网络建立的主要目的是实现计算机资源的共享。

计算机资源主要是指计算机硬件、软件与数据。

②互连的计算机是分布在不同的地理位置的多台独立的“自治计算机”。

连网的计算机既可以为本地用户提供服务,也可以为远程用户提供网络服务。

③连网计算机之间遵循共同的网络协议。

程控电话系统是一种特殊用途的交换设备。

一般由外线与分机构成。

它有若干电话共用一条外线,适用于中、小型企业,也可用于住宅和秘书电话。

集团电话交换机一般不需要专职的话务员和维护人员。

当外线呼入时,可由任一部电话应答,并可以转给所需的被叫。

它具有的功能一般有:会议电话、缩位拨号、热线服务、群呼、遇忙回叫、呼叫转移、呼出限制、呼叫等待、停电自动转移等功能。

是现代化办公中常用的通讯管理手段,使电话管理者可集团性管理外线来电与内线呼出。

集团电话外线指接入集团电话中的外线总数;分机是您为员工所安排的的电话数量。

二、有线电视系统有线电视系统主要由信号源、前端、干线传输和用户分配网络组成。

信号源接收部分的主要任务是向前端提供系统欲传输的各种信号。

它一般包括开路电视接收信号、调频广播、地面卫星、微波以及有线电视台自办节目等信号。

系统的前端部分的主要任务是将信号源送来的各种信号进行滤波、变频、放大、调制、混合等,使其适用于在干线传输系统中进行传输。

系统的干线传输部分主要任务是将系统前端部分所提供的高频电视信号通过传输媒体不失真地传输给分配系统。

其传输方式主要有光纤、微波和同轴电缆三种。

用户分配系统的任务是把从前端传来的信号分配给千家万户,它是由支线放大器、分配器、分支器、用户终端以及它们之间的分支线、用户线组成。

三、自办节目播出系统自办节目可以是机,也可以是电脑,还可以用佳得视自办频道播放器,机方式是将机中的影视节目通过数字改造技术转换为电视可以接收的信号,当然这种方式需要经常换碟片,一年下来购买碟片的成本也不低。

所以我们推荐使用电脑来自办节目,将节目源存储于电脑硬盘中,让电脑播放节目,再通过数字改造技术后将电脑中的节目输出到有线电视中,同原来的数字电视改造的节目混编在一起让房间里的电视可以观看。

电脑自办节目最大的优势可以将用户的相关广告或新闻随时输出到网内的每个电视机终端上面,让外界对客户进一步了解和认识,从而加深客户的知名度。

另外自办节目可以随时直接从网上下载电视剧或电影。

四、视频监控系统闭路电视监控系统主要由前端音视频数据采集设备、传送介质、终端监看监听设备和控制设备组成。

通过在监控区域内安装固定摄像机或全方位摄像机,对监控区域进行实时监控。

通过传输线路将摄像机所收集到的信号传至图像分配器或放大器,然后再传入监视器,实现对监控区域的全面监视。

前端设备:是指系统前端采集音视频信息的设备。

操作者通过前端设备获取必要的声音、图像及报警等需要被监视的信息。

系统前端设备主要包括摄像机、镜头、云台、解码控制器、和报警探测器等。

传送介质:是将前端设备采集到的信息传送到控制设备及终端设备的传输通道。

主要包括视频线、电源线和信号线,一般来说,视频信号采用同轴视频电缆传输,也可用光纤、微波、双绞线等介质传输。

控制设备:是整个系统的最重要的部分,它起着协调整个系统运作的作用。

人们正是通过控制设备来获取所需的监控功能。

满足不同监控目的的需要。

控制设备主要包括音、视频矩阵切换控制器、控制键盘、报警控制器和操作控制台。

终端设备:是系统对所获取的声音、图像、报警等信息进行综合后,以各种方式予以显示的设备。

系统正是通过终端设备的显示来提供给人最直接的视觉、听觉感受,以及被监控对象提供的可视性、实时性及客观性的记录。

系统终端设备主要包括监视器、录像机等。

五、防盗报警系统周界防盗报警系统是防盗报警系统中的一种,它是利用红外对射防盗探测器对一定区域的周边进行布防检测,可以探测到非法侵入本区域的信号,并在探测到非法侵入的同时向有关人员报警,周界报警系统由探测器部分、信号传输部分和控制部分组成。

简单点讲就是在围墙上装红外对射探测器,一个接收红外一个发送红外但必需是在一条直线上,然后后端有一台报警主机用于当前端的探测器红外线被挡住时也就是发送红外线的发出去接收的接收不到红外线,这时它将报警信号发到主机进行报警显示,有效防护周界区域,对翻越行为提供及时报警;控制中心通过警笛对值班人员提示警情发生,便于值班人员即时处理警情;管理中心可与区域安防部门联网,如110、公安部门等,提供社区报警的区域联网保障。

六、公共广播系统公共广播系统是专为公共场所提供背景音乐、广播及消防报警的智能专业设备。

广泛应用于工厂、商住小区、学校、广场、商业大厦、酒店等。

目前,公共广播系统的最大特点是将数码技术应用到公共广播系统中,从而使公共广播系统安装更为方便,功能更为强大,应用更为广泛,操作更为简便。

公共广播系统采用全数位制式,由前端设备(前置放大器、电话接入装置、警报发生器、数码程控主机、程控键盘、调制器、节目电源定时器、音乐源、监听器等)中继、终端设备(音箱、喇叭、小区定压功放等)组成。

功能:1、独立广播。

可对任意终端进行独立广播。

2、矩阵分区。

公共广播系统分区功能由程式控制,可自由设定,包括矩阵分区:每终端可重复分区、自由组合;独立广播;多区广播;全体广播。

3、定时广播。

具有定时、内置定时音乐,可对某个区或全体进行定时广播。

4、直观显示。

采用键盘操作,不仅操作方便,显示更为直观。

七、多媒体会议系统多媒体会议室系统组成由投影机屏幕显示系统、音响系统、视音频交互系统、中央控制系统、计算机网络系统及配套设施构成,各系统主要构成及功能如下。

投影机系统系统构成:主要由大屏幕投影单元集成控制软件等组成。

系统功能:放大、多组合显示计算机信号和视频信号,增强显示效果。

音响话筒系统系统构成:主要由功率放大器、扬声器等设备组成。

系统功能:实现扩声功能,并与大屏幕显示系统、电视电话会议系统集成汇接。

视音频交互系统系统构成:主要由摄像机、云台等前端设备组成。

系统功能:实现各种视频、音频信息的切换、组合显示。

中央控制系统系统构成:主要由控制主机、触摸屏及相关模块等设备组成。

系统功能:主要用于各种视频、音响及多媒体播放设备的集中控制。

计算机网络系统系统构成:主要网络终端等网络设备组成。

系统功能:用于连接系统内部网络设备、计算机终端和其他信息网络,为网上传输数据、图形、视频信息提供软硬件环境支持。

八、门禁管理系统系统功能:1.进出门区管制:管制每个持卡人可以进出哪些门2.进出时间管制:管制持卡人允许进入该门的时间范围3.门位状态侦测显示:显示每个门的开关状态4.开门超时报警:门被打开后超过预设时间门未被关闭就发出警报5.非法入侵报警:当门被非法打开(非刷卡开门)是发出警报6. 硬体破坏报警:当室外的读卡器被人撬开或破坏时发出警报7.微机远端控制各门的开关:通过微机可以打开或关闭某一组门8.门间互锁(防尾随):持卡人必须将刚进入的那扇门关闭才能打开下一个门。

9.返潜回(三层):持卡人必须按预先设计的路线进出,否则刷卡无效10.定时开关门:可在预先设置好的时间段内自动打开或闭合某一组门的电控锁11. 与监控,消防系统等实现联动:例如门被打开时现场即刻被录相;发生火警时所有门的电控锁被自动打开等。

九、考勤管理系统考勤系统是指一套管理公司的员工的上下班考勤记录等相关情况的管理系统。

是考勤软件与考勤硬件结合的产品,一般为部门使用,掌握并管理企业的员工出勤动态。

包括考勤记录、考勤分析两大功能。

根据系统制定的考勤规则,自动分析出考勤结果,是考勤系统的核心。

针对不同的单位、不同的部门,考勤的规则一般都不同。

由于企业的工作内容不同,在不同的时间,有不同的考勤要求。

由于法律、劳工规则的变化,也有不同的考勤要求。

考勤系统需要适用一种经常变化的管理过程。

十、幼儿园接送系统幼儿园安全接送系统是本公司为在幼儿园内推广安全智能化管理,改善幼儿园安全环境而不断推陈出新的产品。

本系统针对幼儿园日常接送工作与各种安全管理需求而设计,是融合了安全接送、教师考勤、视频监控与门禁于一体的智能化安全管理系统。

提供全面的儿童信息记录,幼儿毕业、升级、调班、退学等过程信息可以得到完整的记录。

刷卡拍照功能,入园和离园时红外摄像设备会时时拍照,接送人每次接送都留下了图像可备以后查询。

短信通知功能,当验证成功时,系统会自动发送短信进行通知与接收信息。

语音提示功能,当进行验证时,系统会自动进行语音提示验证成功或失败。

教师考勤功能,可处理各种复杂班次,可方便快捷全面的进行核算及出报表工作,管理人员可为其它教职工进行请假、加班、公出等日常登记的提交及审批工作,老师上下班同样是在指纹/刷卡机进行考勤签到,因此该系统不仅可用于家长接送验证,同时也可用于教职工进行日常考勤。

历史数据查询、各项统计报表、操作日志等为科学管理与分析、高效工作与责任划分等提供依据;十一、交互式智能白板交互式智能白板是一种先进的教育或会议辅助人机交互设备,其融合了精确定位技术、大屏幕显示技术、电子技术和计算机技术,可在电化教室和多媒体会议室内取代传统的投影幕布和黑板/白板的功能。

通过电子白板与计算机和投影仪的配合,讲解者可以在投影内容上直接进行书写、绘画、修改、注释和保存,并可以将电子白板作为人机接口实现对计算机的各种操作。

十二、显示屏简单地讲( )显示屏就是由若干个可组合拼接的显示单元(单元显示板或单元显示箱体)构成屏体,再加上一套适当的控制器(主控板或控制系统)。

所以多种规格的显示板(或单元箱体)配合不同控制技术的控制器就可以组成许多种显示屏,以满足不同环境,不同显示要求的需要。

显示屏可以显示变化的数字、文字、图形图像;不仅可以用于室内环境还可以用于室外环境,具有投影仪、电视墙、液晶显示屏无法比拟的优点。

十三、电子巡更系统巡更系统()是技术防范与人工防范的结合,巡更系统的作用是要求保安值班人员能够按照预先随机设定的路线顺序地对各巡更点进行巡视,同时也保护巡更人员的安全。

相关文档
最新文档