Hemisphere系列板卡测试工装使用手册
哈菲利Axos系列可扩展测试系统产品介绍说明书
Haefely is a subsidiaryof Hubbell Incorporated.a brand ofEXPANDABLE TEST SYSTEMS1981Domestic Industrial Medical ITWhite goods Robotics Monitoring Computers Brown goods Welding machines Scanning Printers Household Packing machines Analysing Modems Lightning devices Production lines Pumps HubsPortable tools LaboratoryequipmentImplants PhonesHome automation ServersRenewable energy Telecom Transportation DefenseSolar panels Outdoor lines Automotive Component testing Windmills Repeater Motorcycles Communications Turbines Switching stations Trucks Vehicles Inverters Data concentrators Electric vehicles AircraftsInfrastructure Telecommunicationcenters Charging stations SatellitesIndoor applicances Outdoor applicancesTHE STANDARDSIEC/EN 61000-4-5 Surge Combination Wave 1.2/50µs...8/20µsSurge events can be generated by lightning phenomena, switching transients or the activation of protection devices in the power distribution system. A surge itself is influenced by the propagation path taken so that impulses from the same event may have different forms depending upon where a measurement is taken. Combination Wave Generators (CWG) simulate a surge event in power lines close to or within buildings. Mostly the disturbances are tolerable because they are single events.THE STANDARDSIEC/EN 61000-4-5T elecom Wave 10/700µs / ITU K.20, K.21, K.44, K.45Telecommunication networks and lines are often disposed to lightning strikes and their associated effects. All telecommunication systems linked with lines in-IEC/EN 61000-4-12 Ring Wave / IEEE C62.41Ring waves are used to simulate lightning or switching effects in domestic single or three phase supplies within an adequately protected building. The waveform has similar characteristics in both open and short circuit conditions. The ring wave is characterised as a bipolar damped oscillating wave.THE MODULAR CONCEPTWelcome to the unique design and concept of modularity designed by HAEFEL Y.HAEFEL Y is recognizing an increasing interest in testing departments to configure the required functions in compact immunity test systems more flexible than ever. For that reason HAEFELY designed a unique concept of modularity which eviscerates large additional investments for customers in the future.Moreover, constantly reduced product development times call for powerful, easy-to-operate and ready-to-use conducted immunity test systems which can be expanded in a multitude of different test applications. Customer requirements, particularly in theAXOS 5 EXPANDABLE TEST SYSTEMAXOS 5 front viewAXOS 5 rear viewThe new AXOS 5 expandable test system integrates all of the best features of several stand-alone test systems into one single economic solution.It can be individually combined either with 5 kV Surge Combination Wave, 5 kV EFT/Burst, Dips & Interrupts, along with an integrated single-phase coupling / decoupling network. This allows quick and completely automated testing to the most common IEC, EN, ANSI, IEEE and UL standards.The AXOS 5 can either be operated via front panel by large colour graphic interface or remotely from the PC. The easy to use menu together with the availability of predefined test routines for different standards makes testing easy and reliable, even for less fre -quently users.Numerous additional functions such as external start/stop function allows easy integration of the test system also in customer specific test environments.All the test parameters can be varied in a broad range wide above the requirements of the standards. Together with the ability of changing test parameters during test, AXOS 5 is not only the ideal product for compliance and pre-compliance testing, it is useful for monitoring & debugging function during design phase as well.A wide range of cost-efficient and user friendly coupling / decoupling networks for power lines as well as for symmetrical and asymmetrical data- and signal lines are available as options.OVERVIEWFEATURES & BENEFITS⏹ Easy to operate with manual and auto-mated test modes, software assisted test preparation, pre-defined test rou-tines and visual aided test setups⏹ Economic & Efficient STANDARDS⏹ IEC/EN 61000-4-4 EFT / Burst⏹ IEC/EN 61000-4-5 Surge Edition 2 & 3⏹ IEC/EN 61000-4-9 Imp Magnetic FieldTECHNICAL DATA - AXOS 5GENERAL DATA Control power 85 V - 264 V 50/60 Hz Dimensions (W x H x D)19“ / 4U(45 x 18 x 49 cm)User test storage unlimited Weight 25 kgRemote interface Ethernet, RJ45USBfor USB memory stick Display7“ / 800x480 / 24 bit with touch-screen AUX. interfaceD-sub 37p for external CDN, external trans-External trigger input5 V T TL Synch input BNC, 10 V – 264 V AC Trigger output5 V T TLExternal start / stop input5 V T TL, starts / stops predefined test se -quenceEUT failed input 5 V T TLAnalog output 0 – 10 V, for use with external options Warning lamp output2 x 24 V / 1 A DCSafety circuitstops the test when unlockedat coaxial output Polaritypos / neg / alternate Burst duration 10 µs – 1 s Output impedance 50 Ohm Burst period 1 ms – 10 s Rise time 5 ns ±30%T est time 1 s– 1'000 minutes Impulse duration50 ns ±30% at 50 Ohm50 ns –15 +100 ns at 1'000 OhmT riggerautomatic, manual,external trigger inputBurst modenormal, continuous, real, randomIntegrated single phase coupling / decoupling network264 V AC / 16 A 220 V DC / 10 AIEC / EN 61000-4-5 EDITION 2 & UPCOMING EDITION 3 SURGE COMBINATION WAVEOutput voltage0.2 – 5.0 kV ±10%Output current0.1 – 2.5 kA ±10% Voltage rise time 1.2 µs ±30%Current rise time8 µs ±20% Voltage duration50 µs ±20%Current duration20 µs ±20%Polarity postive / negative /alternate Integrated singlephase CDN264 V AC / 16 A220 V DC / 10 AOutput impedance 2 OhmOVERVIEW OF AXOS5 SERIES**additional antenna coil "MSURGE-A" required*external voltage dips transformer "DIP 116" required⏹ Activated by default⏹ Optionally available by activation via key codeAXOS5Compact T est SystemArticle no. 2490400Surge 1.2/50µs...8/20µsAXOS5Surge T est SystemArticle no. 2490401Surge 1.2/50µs...8/20µsAXOS5EFT/Burst T est SystemArticle no. 2490402Surge 1.2/50µs...8/20µsIEC/EN 61000-4-5EFT/BurstIEC/EN 61000-4-4Voltage DipsIEC/EN 61000-4-11*Magnetic FieldIEC/EN 61000-4-9**AXOS5Dips T est SystemArticle no. 2490403Surge 1.2/50µs...8/20µsIEC/EN 61000-4-5EFT/BurstIEC/EN 61000-4-4Voltage DipsIEC/EN 61000-4-11*Magnetic FieldIEC/EN 61000-4-9**SCOPE OF SUPPLY - OPTIONS & ACCESSORIESSCOPE OF SUPPLYAXOS5 Compact Immunity Test System 2490400 AXOS5 Surge Test System 2490401 AXOS5 EFT/Burst Test System 2490402 AXOS5 Voltage Dips Test System 2490403 Qty. 1 Immunity Test System AXOS5Qty. 1 Mains CableAXOS8 EXPANDABLE TEST SYSTEMThe new AXOS8 expandable test system integrates all of the best features of several stand alone test systems into one single economic solution.It can be individually combined either with 7 kV Surge Combination Wave, 7 kV Ring Wave, 7 kV Telecom Wave*, 5 kV EFT/Burst or Dips & Interrupts, along with an integrated single-phase coupling / decoupling network. This allows quick and completely automated testing to the most common IEC, EN, ANSI, ITU, IEEE and UL standards.The AXOS8 can either be operated via front panel by large colour graphic interface or remotely from the PC. The easy to use menu together with the availability of predefined test routines for different standards makes testing easy and reliable, even for less frequently users. Numerous additional functions such as external start/stop function allows easy integration of the test system also in customer specific test environments.All the test parameters can be varied in a broad range wide above the requirements of the standards. Together with the ability of changing test parameters during test, AXOS8 is not only the ideal product for compliance and pre-compliance testing, it is useful for monitoring & debugging function during design phase as well.A wide range of cost-efficient and user friendly coupling / decoupling networks for power lines as well as for symmetrical and asymmetrical data- and signal lines are available as options.AXOS8 front view AXOS8 rear view*external T elecom Wave Modul "TW8" requiredOVERVIEWFEATURES & BENEFITS⏹ Easy to operate with manual andautomated test modes, software as-sisted test preparation, pre-definedtest routines and visual aided testsetups STANDARDS⏹ IEC/EN 61000-4-4 EFT / Burst⏹ IEC/EN 61000-4-5 Surge Edition 2 & 3(1.2/50µs...8/20µs)** additional antenna coil "MSURGE-A" required*** external voltage dips transformer "DIP 116" requiredGENERAL DATA Control power 85 V - 264 V 50/60 Hz Dimensions (W x H x D)22“ / 6U(45 x 27 x 50 cm)User test storage unlimited Weight 30 kgRemote interface Ethernet, RJ45USBfor USB memory stick Display7“ / 800x480 / 24 bit with touch-screen AUX. interfaceD-sub 37p for external CDN, external trans-former etc.External trigger input5 V T TL Synch input BNC, 10 V – 264 V AC inputpredefined test se -quenceEUT failed input 5 V T TLAnalog output 0 – 10 V, for use with external options Warning lamp output2 x 24 V / 1 A DCSafety circuitstops the test when unlockedcoaxial outputPolaritypos / neg / alternate Burst duration 10 us – 1 s Output impedance 50 Ohms Burst period 1 ms – 10 s Rise time 5 ns ±30%T est time 1 s– 1000 minutes Impulse duration50 ns ±30% at 50 Ohm50 ns –15 +100 ns at 1000 OhmT riggerautomatic, manual,external trigger inputBurst modenormal, continuous, real, randomIntegrated single phase coupling / decoupling network264 V AC / 16 A 220 V DC / 10 AVoltage rise time 1.2 us ±30%Current rise time 8 us ±20%Voltage duration 50 us ±20%Current duration 20 us ±20%Polaritypos / neg / alternate Integrated single phase CDN 264 V AC / 16 A 220 V DC / 10 AOutput impedance 2 OhmsPhase sync0 – 359° with 1° steps or asynchronous modeImpulse triggerautomatic 2 s – 100 min manualexternal trigger inputCounter preselect 1 – 1000 / infinite Counter 100000Peak voltage monitorBNC output: 1000:1display: 3 digitsPeak current monitorBNC output: 1 kA/V display: 3 digitsTECHNICAL DATA - AXOS 8IEC / EN 61000-4-5 Telecom Wave / ITU K.20, K.21, K.44, K.45Max. voltage0.2 - 7.0 kV ± 10%Sourceimpedance /coupling 15 Ohm40 Ohm40 Ohm gas arrestersFront time OC10 µs ± 30%Outputs 1 x 15 Ohm direct4 x 40 Ohm direct4 x 40 Ohm gas arresters Decay time OC700 µs ± 20%Impulse output Banana connector Undershoot OC< 30%Impulse input HV connectorFront time SC 5 µs ± 20%T ransitions V, PolarityOVERVIEW OF AXOS 8 SERIES* in combination with external T elecom Wave Modul "TW8" ** external voltage dips transformer "DIP 116" required *** additional antenna coil "MSURGE-A" requiredAXOS 8Compact T est System Article no. 2490800Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5 T elecom Wave 10/700µs* AXOS 8Surge T est System Article no. 2490810Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5 T elecom Wave 10/700µs* AXOS 8EFT/Burst T est System Article no. 2490830Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5 T elecom Wave 10/700µs* IEC/EN 61000-4-5 & ITU Ring Wave IEEE C62.41EFT/BurstIEC/EN 61000-4-4Voltage DipsIEC/EN 61000-4-11*Magnetic FieldIEC/EN 61000-4-9**AXOS 8Dips T est System Article no. 2490840Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5 T elecom Wave 10/700µs* IEC/EN 61000-4-5 & ITU Ring Wave IEEE C62.41EFT/BurstIEC/EN 61000-4-4Voltage DipsIEC/EN 61000-4-11*Magnetic FieldIEC/EN 61000-4-9**AXOS8Ring Wave T est System Article no. 2490820 Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5T elecom Wave 10/700µs*AXOS8Telecom Wave System Article no. 2490850 Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5T elecom Wave 10/700µs*** external voltage dips transformer "DIP 116" required *** additional antenna coil "MSURGE-A" requiredSCOPE OF SUPPLY - OPTIONS & ACCESSORIESSCOPE OF SUPPLYAXOS8 Compact Immunity Test System 2490800 AXOS8 Surge Test System 2490810 AXOS8 EFT/Burst Test System 2490830 AXOS8 Voltage Dips Test System 2490840 AXOS8 Ring Wave Test System 2490820 AXOS8 Telecom Wave Test System 2490850 Qty. 1 Telecom Wave Modul "TS 8" 10/700µs*Qty. 1 Mains CableQty. 1 User ManualQty. 1 Certificate of CalibrationOPTIONS AND ACCESSORIESFP-EFT 32M 3-Phase CDN EFT/Burst 32 A / 690 V 2490170 FP-EFT 100M2 3-Phase CDN EFT/Burst 100 A / 690 V 2495860 IP4A Capacitive Coupling Clamp for EFT/Burst 2491300 FP-SURGE 32A Automatic 3-Phase CDN Surge 32 A / 690 V 2490700 FP-SURGE 100M2 3-Phase CDN Surge 32A / 690 V 2490180TW 8 Telecom Wave Modul 10/700µs 4700915 PCD 121 Symmetrical Data & Control Line Coupler 2498010 PCD 126A Asymmetrical Data & Control Line Coupler 2498030 DEC 5 Symmetrical Data & Control Line Decoupler 2490141 DEC 6 Symmetrical Data & Control Line Decoupler 2490151 DEC 7 Asymmetrical Data & Control Line Decoupler 2490161 DIP 116 Automatic Dips Transformer 16 A 40/70/80% 2490410MSURGE-A Magnetic Field Test IEC / EN 61000-4-9 2490441 VTM 15000 Isolation Test 1.2/50 us up to 10 kV 2499960 VTM 15000/05 Isolation Test 1.2/50 us up to 10 kV / 0.5J 2499692 PDP 8000 HV Differential Probe 1000:1 for Surge 2499911 CP 101 Current Probe Model for Surge 2499931 ES External Emergency Stop Switch P12 4700751 WL External Warning Lamp P12 4700750* only with AXOS8 Telecom Wave T est System (2490850)OPTIONS AND ACCESSORIESSurge Key Code Key Code for Surge extension AXOS84700911 EFT/Burst Key Code Key Code for EFT/Burst extension AXOS8 4700912 Ring Wave Key Code Key Code for Ring Wave extension AXOS8 4700913 Dips Key Code Key Code for Voltage Dips extension AXOS8 4700914M a r c h 2013Headquarters China (Sales & Service Office) North American OfficeHaefely T est AG HAEFEL Y Representative OfficeHipotronics Inc.Birsstrasse 300 8-1-602, Fortune StreetHaefely EMC Division4052 Basel No.67, Chaoyang Road, Chaoyang District1650 Route 22SwitzerlandBeijing, China 100025Brewster, NY 10509☎ + 41 61 373 41 11 ☎ +86 10 8578 8099 ☎ +1 845 279 3644 + 41 61 373 49 12+86 10 8578 9908 +1 845 279 2467*************************************.cn****************************。
harness仪器使用培训
Bojay Confidential
1
1.仪器的各部件介绍 使用说明 2.功能选单 3.系统设定与分析模式 4.操作环境设定 5.综合测试设定 6.使用范例
Bojay Confidential
2
②
③
④ ⑤ ⑥
⑦
⑧
⑨
⑩
⒒
⒕
⒓
Bojay Confidential
3
⒕
⒔
Bojay Confidential
Bojay Confidential
5
1.按下Func,LCD显示画面如下1图: 2.按(Enter)即可进入选择项目功能图2: 按下(EXIT)退回上一个页面 3.由LCD可以看出机器的信息
这个是功能选择单键
系统选择单
图1
图2
Bojay Confidential
6
3.Ⅰ操ห้องสมุดไป่ตู้环境设定
工装A插头对应仪器A插 座插装到位
工装B插头对应仪器B插座 插装到位
:
Bojay Confidential
13
测试线材:按仪器“File"键显示测试菜单,在菜单中选择产品编号,按“Enter”键, 画面“目前档案”应显示产品编号,然后按“Test"键进行线材导通性测试:仪器 LED灯亮红灯,说明线材NG,需截出并参照“显示窗口不良项内容”标示清楚, 放入不良品架;仪器LED灯亮绿灯,说明线材良好,将线材热缩管套至焊接处, 用热吹风将热缩管加热紧缩后放入OK品放置架,制作测试下一线材(图a、图b)。
Hemisphere 系列北斗高精度板卡P207用户手册2104-v1.0
Hemisphere系列北斗/GNSS高精度定位板卡P207用户手册V1.0北京合众思壮科技股份有限公司Beijing UniStrong Science & Technology Co.Ltd.目录第一章接收机综述 (1)1.1 产品概述 (1)1.2 产品主要特点 (1)1.3技术规格 (2)第二章硬件组成 (4)2.1机械尺寸 (4)2.2管脚定义 (5)2.3接口信号 (6)2.3.1RF输入 (6)2.3.2 串口 (6)2.3.3 USB口 (6)2.3.4 LED指示灯 (7)2.3.5 1PPS时间信号 (8)2.3.6事件标识输入 (8)第三章连接与设置 (9)3.1 加电启动 (9)3.2设置接收机数据输出 (9)3.2.1 THIS 端口和OTHER 端口 (10)3.2.2 保存当前配置 (11)3.3配置端口D接收RTCM信息(信标或L-BAND功能) (11)第四章常用设置指令说明 (12)4.1 NMEA 0183消息结构 (12)4.2 常用操作指令 (13)4.2.1 $JI (14)4.2.2 $JK (14)4.2.2 $JK,SHOW (15)4.2.3 $JPOS (15)4.2.4 $JBOOT (16)4.2.5 $JRESET (16)4.2.6 $JSA VE (17)4.2.7 $JSHOW (17)4.2.8 $JT (18)4.2.9 $JAPP (19)4.2.10 $JBAUD (20)4.2.11 $JDIFF (20)4.2.12 $JPPS,WIDTH (21)4.2.13 $JPPS,FREQ (21)4.3 GNSS指令 (21)4.3.1 $JASC (22)4.3.2 $JAGE (22)4.3.3 $JOFF (22)4.3.4 $JMASK (23)4.3.5 $JNP&$JNMEA,PRECISION (23)4.3.7 $JSMOOTH (24)4.4 RTK基准站和流动站设置 (24)4.5数据消息 (26)4.5.1 GPGGA (26)4.5.2 GPGLL (27)4.5.3 GSA (28)4.5.4 GPGST (29)4.5.5 GSV (30)4.5.6 GPRMC (31)4.5.7 GPRRE (32)4.5.8 GPVTG (33)4.5.9 GPZDA (33)第五章二进制消息 (35)5.1 二进制消息类型 (35)5.1 二进制消息结构 (36)5.1.1 BIN1消息 (36)5.1.2 BIN2消息 (38)5.1.3 BIN62消息 (39)5.1.4 BIN65消息 (39)5.1.5 BIN66消息 (40)5.1.6BIN69消息 (41)5.1.7 BIN76消息 (42)5.1.8 BIN80消息 (45)5.1.9 BIN93消息 (45)5.1.10BIN94消息 (46)5.1.11 BIN95消息 (47)5.1.12 BIN96消息 (48)5.1.13 BIN97消息 (49)5.1.14 BIN98消息 (50)5.1.15 BIN99消息 (51)第一章接收机综述1.1 产品概述Hemisphere系列P207是一款高性能的BDS/GPS/GLONASS三星单频定位接收机,通过接收SBAS或外部差分信号,可以提供亚米级定位精度,且数据输出速率可高达20Hz。
横河DCS操作工手册簿
横河DCS操作工手册横河西仪系统部 - 1 - 神马特品工业丝CS3000系统运行操作说明第1 页共25页神马特品工业丝CS3000 系统应用软件操作说明书横河西仪系统部出版发行2006/05/01横河西仪系统部 - 2 - 神马特品工业丝CS3000系统运行操作说明第2 页共25页总目录一、前言-------------------------------------------------------------------------- -3-二、流程图画面总目录 ---------------------------------------------------------- -4-三、软件操作说明 --------------------------------------------------------------- -14-1、画面操作 ----------------------------------------------------------------- -14-1-1 总貌画面 ---------------------------------------------------------- -14-1-2 流程图画面 ------------------------------------------------------- -14-1-3 控制分组画面 ---------------------------------------------------- -15-2、仪表操作 ----------------------------------------------------------------- -16-2-1 开关仪表面板 ---------------------------------------------------- -16-2-2 调节仪表面板 ---------------------------------------------------- -173、报表操作 ----------------------------------------------------------------- -17-四、系统操作说明 --------------------------------------------------------------- -18-1、人机接口 ---------------------------------------------------------------- -18-1-1 人机接口功能 ----------------------------------------------------- -18-1-2 窗口类型 ----------------------------------------------------------- -181-3 窗口操作 ----------------------------------------------------------- -19-1-4 典型的操作监视窗口 -------------------------------------------- -192、系统基本维护 ---------------------------------------------------------- -30-2-1 系统维护窗口 ------------------------------------------------------ -30-2-2 过程报告书 --------------------------------------------------------- -332-3 历史报告书 --------------------------------------------------------- -33-3、操作员键盘---------------------------------------------------------------- -34-五、后记------------------------------------------------------------------------------ -35-横河西仪系统部 - 3 - 神马特品工业丝CS3000系统运行操作说明第3 页共25页前言神马特品工业丝计算机分散控制系统采用横河西仪提供的CENTUM-CS3000 控制系统。
稳定性测试及诊断二合一卡说明书
电脑故障诊断与稳定性测试二合一卡使用说明书V1.1先进独特,用卡必读中国创造专利专利证书号:208776侵权必究中国·广东·奇冠电子研制前言非常感谢您选择奇冠公司的二合一卡系列产品,如果您有什么疑问,请登陆我司网站61131568 查询详情解答;您还可以将具体问题发E-mail 到p678@,我们会及时回复您。
感谢您的信赖和支持!奇冠电子电脑故障诊断与稳定性测试二合一卡,是一款高性能卡,即能对电脑故障诊断,又可对其稳定性测试。
功能二卡合一,方便适用。
本卡采用大规模IC集成模块,结构紧凑,稳定可靠,确保产品品质符合高标准要求。
内部资源更丰富,抗干扰性能更优越,自身故障率极低。
无须用户安装软件,软件全部内置,我们将前沿科技与使用者行为科学相结合,进行了人性化功能设计,使用非常方便。
本公司是一家专业研发、生产诊断卡的企业,生产的新一代、准确王、及二合一卡系列产品已获CE认证并受中国国家专利保护〔〕,侵权必究。
我公司已不再生产传统诊断卡,请广阔用户在购置时认准“奇冠〞字样商标及防伪标识。
本用户手册所提到的产品规格及资讯仅供参考,实际内容亦会随时更新,恕不另行通知。
如果您要了解最新产品资讯,请访问我公司网站。
欢迎访问广州奇冠电子公司网目录一、二合一卡部件介绍 (4)稳定性二合一卡部件图〔以MKCP6为例〕 (4)主板连线图 (5)二、二合一卡功能特点 (6)〔一〕稳定性测试功能特点 (6)〔二〕二合一卡指示灯特性 (7)〔三〕故障诊断功能 (8)三、二合一卡稳定性测试流程 (9)四、二合一卡结果显示含义介绍 (10)1.代码性质与稳定性测试结果结合分析及处理方法说明表 (10)2.稳定性测试状态 (11)3.指示灯状态 (11)五、根本操作流程 (13)附图1、检测流程总图 (14)附图2:“不稳定〞原因判断流程图 (15)附图3:引起“不稳定〞故障部位判断及排除流程图 (16)附图4:采用相应手段诱发出引起“不稳定〞的原因流程图 (17)附图5:复位故障判断流程图 (18)附图6:利用二合一卡判断是否为市电引起流程图 (19)附图7:利用二合一卡判断是否为内存条混插引起流程图 (20)附图8:利用二合一卡判断是否为电源负载能力不够引起流程图 (21)附图9:利用二合一卡判断是否为散热不良引起流程图 (22)附图10:利用二合一卡判断是否为灰尘引起流程图 (23)附图11:利用二合一卡判断是否为强磁干扰引起流程图 (24)附图12:利用二合一卡判断是否为接触不良引起流程图 ............................ 25 六、常见问题与解决方法: . (26)1. 如何利用二合一卡选配电脑工作稳定的UPS ? ........................................ 26 2. 如何利用二合一卡检验开发的外围设备对电脑的干扰? ........................ 27 3. 如何利用二合一卡挑选用于重要场合的电脑? ........................................ 28 4. 测试时不拔除硬盘会对电脑有何不利? .................................................... 29 5. 为何刚刚用着很好的电脑翻开机箱后就坏了? ........................................ 29 6. 如何选购稳定性测试卡? ............................................................................ 29 7.为什么Clock 指示灯要改进,改进后有何好处? (29)一、二合一卡部件介绍稳定性二合一卡部件图〔以MKCP6为例〕复位线连接至机箱复位开关,如不使用连接至主板RESET 插针实物与图片存在差异,以实物为准,我司会不断对产品改进,恕不另行通知。
OMEGA PHH222 胶囊式pH mV测量器说明书
PHH222, pH/mV Fra biblioteketer, PHE-1411, pH electrode.
To download information and to order pH Field and Lab Instrument products online, visit
oOrdmer Oenlinge ® Over 100,000 Products Available!
To Order
Model No. PHH222
Description pH/mV meter/temp with RS232
Accessories
Model No.
Description
HHWT-SD1-ATC Temperature probe for PHH222
SWCABLE
RS232 cable and windows software
PHE-1411
pH lab electrode
PHA-4
4.00 pH buffer solution 500 ml (1 pint) bottle
PHH222, shown smaller than actual size with optional PHE-1411 electrode.
Specifications
Measurement: pH/mV/Temperature Accuracy: ±(0.02 pH + 2 d) ±(0.5% + 2 d) Display: 51 x 32 mm, dual function LCD, 15 mm (0.6") digit Range: 0 to 14/-1999 to 1999 mV Resolution: 0.01 pH/ 1 mV Input Impedance: 1012 Ω Temperature: Manual or automatic 0 to 65°C Compensation: (Temperature probe) Data Output: RS232 Data Hold: Yes Sampling Time: Approx 0.8 sec Operating Temperature: 0 to 50°C (32 to 122°F) Operating Humidity: Less than 80% RH Memory Recall: Maximum/Minimum Power Supply: 9V battery (included) Power Consumption: Approx 8 mA Electrode Connection: BNC Dimensions: 205 x 68 x 30 mm (8.1 x 2.7 x 1.2") Weight: 250 g (0.55 lb)
切尔哈姆合光电感应传感器E58-30系列用户手册说明书
Models covered in this manual:AC/DC Models w/ CableAC/DC Models w/ ConnectorDC-only Models w/ CableDC-only Models w/ ConnectorLight Operate Dark Operate Light Operate Dark Operate Light Operate Dark Operate Light Operate Dark Operate PolarizedE58-30RP10-GLE58-30RP10-GDE58-30RP10-GLPE58-30RP10-GDPE58-30RP10-HLE58-30RP10-HDE58-30RP10-HLPE58-30RP10-HDPInstallation Instructions—E58-30 Series Polarized Reflex Sensors Document 108623-400 Rev 02Cutler-Hammer Photoelectric SensorsWARNING!•These products are not designed, tested, or recommended for use in human safety applications.•This product has no user-serviceable parts—please return to the factory for repairs. The cable clamp on the back of the sensor does not require adjustment. Any attempt to tighten or loosen this part will compromise sealing and void warranty.•AC/DC connector version sensors are equipped with an AC-type connector. The use of DC power with AC-type connectors may not conform with established standards.D C 10 t o 30 V*Note: No connection when using thru-beam sources+V( - )D C 15 t o 30 V*Note: No connection when using thru-beam sources+VAC/DC Models (DC Connection, see Warning above)DC ModelsWIRING DIAGRAMSFor wiring cable versions, the color codes shown are the actual wire colors emanating from the sensor. For connector versions, the pin numbering and color codes shown are typical of several manufacturers, however, variations are possible. In case of discrepancies, rely on function indicated and pin location rather than pin number or color code.AC/DC Models (AC Connection)A C 20 t o 264 V*Note: No connection when using thru-beam sources L1L2REFLEX SENSINGA reflex sensor has both a light source and detector in the same unit. The source sends a beam of light to a retroreflector which returns it back to the detector. A break in the light beam causes the sensor to change output state.The polarizing filter conditions the beam so that light reflected off the retroreflector is detected,but light reflected by the target is not. This ensures reliable detection of shiny targets.MOUNTING LOCATION AND SET-UPLocate the sensor and retroreflector onopposite sides of the target. Ensure that the area of the target to be detected will block the entire effective beam.With power applied to the sensor, aim the unit directly at the center of the retroreflector. Move the sensor back and forth in one plane to find the extreme positions where the output indicator goes “off” (for light-operate mode, or “on” for dark-operate mode). Position the sensor midway between the two extremes.Repeat this procedure for the other plane. After alignment, tighten all mounting screws. An alternate method is to look at the retroreflector with your eye as close to the sensor as possible and align the sensor until reflected light is brightest.Stretch wrap material over a shiny surface may reflect enough light to false trigger a polarized reflex sensor. In this case, tilt the alignment axis of the sensor relative to the shiny surface.USING RETROREFLECTIVE TAPERetroreflective tapes can have vastly different properties than corner-cube reflectors. Polarized reflex sensors will not function with some types of tape (use only corner-cube style tape). Also,signal strength can drop dramatically as thedistance between tape and sensor is reduced. If you intend to use tape with a polarized sensor,especially if mounted closer than 18 inches from the sensor, we recommend that you test your particular tape prior to installation.MOUNTINGhole, or a variety of accessory mountingbrackets.*This manual also covers the model numbers above with the options suffix -FC and -FSC (see “Specifications” on last page for differences)INTRODUCTIONThe E58-30 Photoelectric Sensor line was designed to withstand your harshest physical,chemical, and optical environments. Tough environments like:Automotive—Survives constant exposure to lubricants, cutting fluids, coolants and glycols,plus flying metal cutting chips and tough physical abuse.Food processing—Unaffected by high-pressure chemical washdowns using sanitizers,surfactants, and cleaning agents including diluted bases & acids.Forest industry—Resists anti-fungal and anti-stain agents, wood preservatives, pitch and lubricants.RUGGED PHYSICAL CONSTRUCTION A strong metal housing with mechanical seals and surface mount electronics stand up to heavy shock and vibration.EXCEPTIONAL ENVIRONMENTAL PROTECTION AND CHEMICAL COMPATIBILITYExtensive research dictated the choice of materials used in this sensor to provide exceptional protection in harsh ponents are mechanically assembled using Viton seals to ensure complete sealing and resistance to industry chemicals.UNPARALLELED OPTICAL PERFORMANCE Advanced 30 mm optics and extremely high sensing power combine to produce a polarized reflex sensor with an impressive 34 foot sensing range.AC/DC MODELS (AC Operation)AC/DC MODELS (DC Operation)DC-ONLY MODELSInput Voltage 20 to 132 V ac, 50/60 Hz 15 to 30 V dc 10 to 30 V dc Power Dissipation 3 W maximum 3 W maximum 2 W maximum Output Type VMOS (bi-directional)NPN (sink)NPN and PNP (dual outputs)Current Switching 300 mA maximum 300 mA maximum PNP (source): 100 mA max.; NPN (sink): 250 mA max.Voltage Switching 375 V peak maximum 375 V peak maximum 30 VDC maximum Off-State Leakage 250 µA typical; 500 µA maximum 250 µA typical; 500 µA maximum 10 µA maximum Surge Current 2 A maximum 2 A maximum 1 A maximum On-State Voltage Drop - - - 1.8 V at 10 mA; 4.0 V at 300 mA NPN: 1.2 V at 10 mA, 2.0 V at 250 mA; PNP: 2.8 V at 100 mAResponse Time 10 mS 2 mS 2 mSShort Circuit Protection Sensor will turn off immediately when a short or overload is detected (Indicator LED will flash). Turn power OFF and back ON to reset.Light/Dark Operation By model Temperature Range Operating and Storage: -40° to +131° F (-40° to +55° C)Enclosure Material Cable Jacket: PVC Lens Cover: Glass (or hard-coated cast acrylic for models ending in FC or FSC)Indicator Ring: PVDF (high-density fluorinated polymer)Body: 303 Stainless Steel (or 316 Stainless Steel for models ending in FC or FSC)Seals: Viton ® (registered trademark of Dupont)Cable Clamp: 303 Stainless SteelCable/Connector 6-foot cable, 3-wire (AC/DC models), 4-wire (DC-only models); Micro Connector, 4-pin male Vibration and Shock Vibration: 30 g over 20 Hz to 2 kHz; Shock: 100 g for 3 mS 1/2 sinewave pulse Indicator LED Lights steady when output is ON; Flashes when short circuit protection is in latch condition Sunlight Immunity 10,000 foot-candles Enclosure Ratings NEMA 1, 2, 3, 3R, 3S, 4, 4X, 6, 6P, 12, 12K, and 13; This product is suitable for high temperature, high pressure washdown (1200 psi).Chemical Compatibility This product was designed to withstand chemicals commonly used in the automotive, machine tool, food processing and forest industries.Consult factory for compatibility with specific chemicals.Approvals Contact factory for the latest list of agency approvalsCutler-Hammer Photoelectric SensorsSPECIFICATIONSCutler-Hammer 720 80th Street SW Everett, WA 98203-6299206/353-0900 Fax: 206/513-5302Cutler-Hammer Canada 3228 South Service Road Burlington, ON L7N 3H8800/268-3578 905/333-6442 Fax: 905/333-2724For service or more information call:1-800-426-9184DIRECTLINE Application Assistance:Fax-206-513-5356Specifications subject to change without notice.108623-400; Printed in USA (11/99)SMOOTH-BODY MODELS (model numbers ending in FSC)OPTICAL PERFORMANCEAll optical specifications are guaranteed to be the minimum performance under clean conditions of any product delivered from stock.Typical performance may be higher.Dirt in the environment will affect optical performance by reducing the amount of light the sensor receives. For best results, sensors should be used at distances where excess gain is higher than 1.5 (1.5 times the amount of sensing power required to detect an object under ideal conditions). Higher excess gain will allow the sensor to overcome higher levels of contamination on the lens or retroreflector.APPROXIMATE DIMENSIONS (SHOWN IN INCHES EXCEPT WHERE NOTED)THREADED MODELSE58-30 Polarized Reflex Source Light Visible red, 680 nm Optimum Range 1 to 20 feet (0.3 to 6 m)Maximum Range 34 feet (10 m)Field of View6 inch diameter at 20 feet1.Performance to 3-inch retroreflector2.Performance to corner-cube retroreflective tapeRANGE (feet)E X C E S S G A I NRANGE (m)。
海默三丰粗糙度仪安全操作及保养规程
海默三丰粗糙度仪安全操作及保养规程前言为确保海默三丰粗糙度仪的正常使用和使用者的人身安全,本文档旨在详细介绍海默三丰粗糙度仪的安全操作和保养规程。
操作安全规程1. 预备工作在操作海默三丰粗糙度仪前,请务必检查以下事项:•仪器处于稳定的工作环境,不受强烈震动和电磁干扰的影响;•仪器与电源通过正确的电缆连接,并接通电源;•检查仪器是否与其他设备的电气地线连接正常;•保持操作环境的清洁和整洁,以免影响测量结果。
2. 操作步骤在操作海默三丰粗糙度仪时,请遵循以下步骤:1.打开电源开关,启动设备。
此时设备进行自检操作,请不要点击任何按键。
2.待设备完成自检操作后,进入菜单界面。
3.选择“测量”菜单,设置需要测量的参数,如:滑块使用方法、测量间距、测量速度等。
4.将待测物体固定在台面上,并用导电介质润湿表面(建议使用专用导电液)。
5.将传感器头放置于物体表面,按下测量键开始测量。
6.测量完成后,保存数据,并清理设备表面,关闭电源开关,断开电源连接。
3. 注意事项在操作海默三丰粗糙度仪时,请注意以下事项:1.请务必穿戴适当的防护设备,如护目镜和手套等。
2.测量前请检查仪器和待测物体的表面是否清洁,以免影响测量结果。
3.触摸仪器表面时,请勿使用粗糙、尖锐的物体,以免刮伤表面。
4.操作过程中请勿在设备表面放置任何不相关的物品,以免影响测量精度。
5.操作完成后,请及时保存数据并清理设备表面,确保仪器干净、整洁。
维护保养规程1. 清洁维护在日常使用中请注意以下维护事项:1.操作完成后,请及时清理仪器表面,去除灰尘和污渍,避免对仪器表面磨损,影响使用寿命。
2.清洁时,请勿使用刷子或者刮片等尖锐物体,以免刮伤仪器表面。
3.清洁或更换传感器头时,请按照说明书操作,避免损坏传感器头。
2. 定期校正海默三丰粗糙度仪需要定期进行校正,以确保测量结果的精确性。
建议每半年或使用一定次数后进行一次校正。
3. 收纳存放使用完毕后,请将海默三丰粗糙度仪放置在干燥、通风、不受阳光直射和化学品腐蚀的环境中,避免仪器受潮和腐蚀。
费渣海 PK 物流电子测量仪说明书
Resistivity Mini-Controller
Resistivity, measured in MΩ (Ohm's), is the optimal way to measure the quality of water produced by high purity systems such as R.O systems and water conditioning equipment. As filter systems become less effective, the resistivity value will decrease indicating a need for maintenance and/or replacement of filters and critical components. Properly functioning RO and water conditioning systems will consistently produce water with resistivity readings in the range of 16 to 18MΩ.
P-L BLCONTROLLERS 1.02.1 PRINTED IN USA
Authorized Distributor
ISO
9001
CERTIFIED
ISO
9001
CERTIFIED
Fire retardant casing Larger LCD Selectable overdose protection system External disable feature Selectable control override Matching pin connection 4-20 mA analog output
测试设备手持数字压力计 HM28 参考指南说明书
Handheld Digital ManometerHigh Accuracy (0.2%, 0.1% or 0.05%), Differential, Gage or AbsoluteSeriesHM28SPECIFICATIONSPressure Connection: Hose; 4/6 mm or 1/8˝ NPT.Accuracy: (Includes linearity, hysteresis, and repeatability): per order code.±0.20% full-scale ±1 digit±0.10% full-scale ±1 digit±0.05% full-scale ±1 digit.Measuring Media:Instrument air or inert gases. For HM28G3XXXXX, any material compatible with 18/8 stainless steel.Temperature Limits:23 to 122°F (-5 to 50°C).Storage Temperature: -4 to 140°F (-20 to 60°C).Humidity: 30 to 95% rH, non-condensing.Display:2 line, 16 character, dot matrix LCD, with switchable display sizes.Power Requirements:9 V alkaline battery, installed functional, user replaceable. Can operate from external power supply of 7 to 14 VDC.Current Consumption:< 9 mA.Memory: 964 measured values. Recording intervals adjustable from manual, 1, 5, 10, 20,30 seconds, 1, 2, 3, 5, 10, 30, 60 minutes.Case Protection:IP54 (NEMA 3).Case Dimensions: 6˝ x 3.27˝ x 1.34˝ (152 x 83 x 34 mm).Weight:9.5 oz (270 g).Maximum Measurement Rates: Stand alone: 2-1/2 readings/s (0.1% and 0.05% ratings),5 readings/s (0.2% rating). Output to RS-232: 20 measurements/s (0.2% rating). 10measurements/s (0.1% and 0.05% ratings).RS-232 Baud Rate: Adjustable, 1200, 2400, 4800, or 9600 baud.Agency Approvals:CE.The Series HM28 Digital Hand-Held Manometer is a precision instrument designed to measure a wide range of pressures to a very high accuracy. The unit incorporates a variety of features in an easy to use format that makes it useful in a wide variety of applications. Features include: measurement in all common pressure ranges, display resolution to 0.001, differential or relative measurement, two line liquid crystal display, and adjustable auto power off to conserve battery.We are so proud of the accuracy of the HM28 that we provide a certificate of calibration with the unit at no additional cost. Depending on your application, the HM28 can be used as a secondary calibration standard for your other pressureinstrumentation.OPTION For NIST traceable calibration certificate, use order code NISTCAL-MD.ACCESSORIES HM28-0,1/8˝ NPT Adaptor 1 piece HM28-1,Communication Software & Cable HM28-2,Universal Power Adaptor。
Renishaw MH20 和 MH20i 手动测量头系列说明书
MH20 and MH20iManual probe heads with modular flexibilityImproving the performanceof Co-ordinateRenishaw’s extensive range of manual head systems provide an economical solution to everyday inspection needs.MH20 and MH20i are principally designed for installation on manual CMMs, however their productivity enhancing modular flexibility and compact design means they are also suitable for smaller DirectComputer Controlled (DCC) CMMs, where automatic stylus changing is not a requirement.For the convenient storage of probe modules, MSR1 (manual storage rack) provides protection from possible contaminants in the working environment. It is available for mounting on horizontal or vertical surfaces.Module storageImproved performance The MH20 and MH20i are the new generation of manually adjustable probe heads from Renishaw.Suitable for installation on new and existing Co-ordinate Measuring Machines (CMMs), both probe headsincorporate Renishaw ’s TP20 kinematic probe mount,which permits repeatable probe module changing. This unique system enables productivity improvements to be made through rapid changes in probe/stylusconfigurations. The incorporation of the modified TP20kinematic probe mount results in a compact design permitting a larger CMM working volume.Benefits include:G Enhanced inspection capability through adjustable probe orientation.G Improved productivity by means of probe module changing without re-qualification.G Optimum working volumes provided by compact design.G Choice of fully flexible (MH20) or indexable (MH20i) orientation.G Smooth position changing through purpose designed locking mechanisms.G Easy installation on CMMs using industry standard shanks.Modular stylus changingBoth heads have been specifically designed to maximise the benefits associated with Renishaw ’srevolutionary TP20 probe system. This concept enables various different probing configurations to be used during an inspection cycle without the need for time consuming probe re-qualification. The TP20 probe module range provides a selection of trigger force,length and directional sensing options and allows a maximum stylus carrying capability of 60 mm and overall reach of 145 mm. The current range includes:For general use:G Standard, medium and extended force probe modules, suitable for most applications.Two additional standard force probe modules providing extended reach:G EM1 and EM2 (50 mm and 75 mm extra reachrespectively).Two probe modules that are designed specifically for specialist applications:G Low force for measurement of delicate objects.G6-way sensing for measurement of undercuts where access limitations would otherwise make inspection difficult.The four trigger force levels ensure measurement consistency and eliminate the requirement for manual adjustment.MH20Ultra compact manually adjustable probe head The MH20 is a compact probe head offering maximum flexibility in probe orientation. The full range of TP20 probe modules can be used via its integral probe mounting.Key benefits:G Ultra compact design maximises CMM working volume.G Flexible probe orientation optimises work-piece accessibility.G Repeatable TP20 stylus module changing designed to enhance productivity.G Easy installation on to new and existing CMMs via a range of standard shanks.MH20iCompact probe head with repeatable indexingThe MH20i offersthe significantadvantage ofrepeatableindexing positions,vastly improvingproductivity formulti-orientationmeasurementapplications. Idealfor use whereseveralprobe/stylusconfigurations andhead positionsenable thecomprehensivemeasurement of apart in a singleroutine.Key benefits:G Repeatable indexpositionseliminatethe need for constant re-qualification.G168 positions (at 15°increments) offer maximum flexibility in repeatable probe orientation.G Lock /unlock feature allows ease of positioning and eliminates unnecessary wear.G Easy-to-read scales for rapid re-orientation to qualified positions.For further information on the MH20 and MH20i please refer to Data Sheet H-1000-2195A Tech Authoirty, Inc 3857 Schaefer Ave, Ste C Chino, CA. 91710 (909)972-7520Authorised distributor Australia- Renishaw Oceania, MelbourneTel +61 3 9553 8267 Fax +61 3 9592 6738email:**********************Brazil- Renishaw Latino Americana Ltda, São Paulo Tel +55 11 4195 2866 Fax +55 11 4195 1641email:*******************The Peoples’ Republic of ChinaRenishaw Representative Office, BeijingTel +86 10 6410 7993 Fax +86 10 6410 7992email:******************Renishaw Representative Office, ShanghaiTel +86 21 6353 4897/5697 Fax +86 21 6353 4881 email:******************France- Renishaw S.A., Marne la ValléeTel +33 1 64 61 84 84 Fax +33 1 64 61 65 26email:*******************Germany- Renishaw GmbH, PliezhausenTel +49 7127 9810 Fax +49 7127 88237email:********************Hong Kong- Renishaw (Hong Kong) Ltd, Kowloon Bay Tel +852 2753 0638 Fax +852 2756 8786email:*********************India- Renishaw Metrology Systems Pvt Ltd, Bangalore Tel +91 80 5320 144 Fax +91 80 5320 140email:******************Indonesia- Renishaw Representative Office, Jakarta Tel +62 21 428 70153 Fax +62 21 424 3934email:**********************Italy- Renishaw S.p.A., TorinoTel +39 011 966 10 52 Fax +39 011 966 40 83 email:******************Japan- Renishaw K.K., TokyoTel +81 3 5332 6021 Fax +81 3 5332 6025email:******************Singapore- Renishaw Representative OfficeTel +65 8975466 Fax +65 8975467email:**********************South Korea- Renishaw Liaison Office, SeoulTel +82 2 565 6878 Fax +82 2 565 6879email:***********************Spain- Renishaw Iberica S.A., BarcelonaTel +34 93 478 21 31 Fax +34 93 478 16 08email:******************Switzerland- Renishaw A.G., PfäffikonTel +41 55 410 66 66 Fax +41 55 410 66 69email:************************Taiwan- Renishaw Representative OfficeTel +886 4 251 3665 Fax +886 4 251 3621email:*******************UK (Head Office)- Renishaw plc, GloucestershireTel +44 1453 524524 Fax +44 1453 524901email:***************USA- Renishaw Inc., IllinoisTel +1 847 286 9953 Fax +1 847 286 9974email:****************For all other countriesTel +44 1453 524524 Fax +44 1453 524901email:**************************SALES & SERVICE:A Tech Authority, Inc. 13745 Stockton Ave. Chino CA 91710909-614-4522************************。
Hemisphere系列板卡常用指令集v2.1-20140801
3Leabharlann 自适应, 解决输入基线长精度不高或者, 基线变化后航向不 解算问题) 接收机默认设置,此时横滚值非 GNSS 天线测量值,是倾
$JATT,ROLL,NO 斜传感器测得值。 此时设置横滚值由 GNSS 天线测量,但要求 GNSS 天线按 $JATT,ROLL,YES 横滚方向安装。 打开接收机反置命令,当接收机上下 180°反转安装时, 为 $JATT,FLIPBRD,YES 确保测量横滚值的准确性, 需打开此指令。 默认设置为关闭 $JASC,INTLT,1 $JATT,HBIAS,X +180° $JASC,GPROT,1 输出接收机转速值,单位°/min 以 1HZ 速率输出倾斜传感器测得的俯仰,横滚值。 设置航向偏离校正值 x, 默认为 0°,取值范围为-180°~
输入天线间距,单位:米(测量值误差最好在 2cm 以内) 查询当前输入接收机的天线间距测量值 查询接收机自身解算出的天线间距值 打开陀螺 关闭陀螺 查询陀螺当前状态 打开倾斜传感器 关闭倾斜传感器 查询当前倾斜传感器的状态 打开移动基准站功能 (此功能可使得接收机对基线变化进行
$JATT,MOVEBASE,YES
3.常用测向指令
消息 $JASC,GPHDT,1 $JASC,GPHPR,1 测向;G=陀螺测向)
2
描述 输出航向信息,输出频率 1HZ 输出 UTC 时间, 航向, 俯仰, 横滚, 当前测向模式 (N-GPS
$JATT,MSEP,X $JATT,MSEP $JATT,CSEP $JATT,GYROAID,YES $JATT,GYROAID,NO $JATT,GYROAID $JATT,TILTAID,YES $JATT,TILTAID,NO $JATT,TILTAID
测试工装的操作说明
测试工装的操作说明
F D F C F B F A
步进电机的四个相序灯
电加热外风机压缩机四通阀
220V AC电源指示灯
三.测试工装引出线的作用示意图
123456789
3.4为PG电机接口,只适用于35灵感型。
4.5为步进电机接口,只适用于35灵感型。
5.6为压缩机继电器接口,连接线为棕线。
6.7为外风机/四通阀接口,连接线为白/红。
7.8、9为电加热接口,连接线为红/红。
四.实际操作说明
KFRd-35GWL(e50345)
1.将1(棕)、2(蓝)电源线分别与RY101“4”、CN101相连接。
2.将3与“CN104”相连
3.将4与“CN102”相连。
4.将5与“CN103”相连。
5.将6(棕)与RY101“3”相连接。
6.将7(白/红)与“CN108”相连。
7.将8、9分别与“CN109”、“CN110”相连
8.将铜封探头、诛封探头分别插入“CN107”、“CN106”;灯板与“CN105”相连。
五.注意事项
1.上述操作应在断电状态下进行,严禁上电状态操作,以防触电。
第2 页共 2 页。
手持环境测量仪 HHEM-SD1说明书
HANDHELD ENVIRONMENTAL METER WITH SD CARD FOR DATA LOGGING C-1C U M ulti-Function ProbeMeasures Air Speed, Temperature, Humidity, and Light LevelU S urface Temperature andSound Level (Optional)U L arge Easy-to-ReadGreen Backlit LCD U M aximum and MinimumReadings with Hold FunctionU A utomatically LogsTime Settable From 1 Second to 1 Hour U S upports Manual Data Logging and Changing of SD Card Storage Location U A uto Power Off Function The HHEM-SD1 meter comes with a multi-function probe that is used to make air speed, humidity and light measurements. Surface temperature and sound level are made using optional accessories. Several features and capabilities enhance the meter’s versatility, among them are automatic temperature compensation for measurements made by the anemometer, a Type K or J thermocouple input, the ability to hold readings and display maximum or minimum readings, and an automatic power off function that extends battery life.Because it is microprocessor-based, the HHEM-SD1 can make full use of being portable. Reliability and large storage capacities are enhanced by an SD memory card.Measurements can be made automatically at any sampling rate between one second and one hour. After time-stamping and storing the measurements on an SD card plugged into the instrument, the user can remove the SD card and plug it into to a laptop or desktop computer either directly or via a USB card reader. The data is stored on the card as files with the .xls extension, which can be opened by Microsoft’s Excel application.HHEM-SD1SPECiFiCATiOnSMeasurement Ranges: A ir Speed: 0.4 to 25 m/sec, 1.4 to 90 km/hr, 0.9 to 55.9 mph, 0.8 to 48.6 knots, 80 to 4930 ft/min Humidity:0 to 85% RH Temperature: 0 to 50°C (32 to 122°F); for RH, 10 to 95% Light Level: 0 to 20,000 lux,0 to 1860 ft-cd Accuracy: A ir Speed: ±(2% + 0.2 m/sec), ±(2% + 0.8 km/hr), ±(2% + 0.4 mph), ±(2% + 0.4 knots), ±(2% + 40 ft/min) (%’s are of full scale) Temperature: 1.5°F (±0.8°C)Humidity: ±(3% of rdg + 1% FS) for RH values >70% ±3% of rdg for RH values <70%Light Level: ±(5% of rdg ±8 digits)The HHEM-SD1 has a backlit 21⁄2" diagonal display and is powered by 6 “AA” alkaline batteries (included) or an optional 9 Vdc AC adaptor.Data Logging Sampling Time:1 second to 1 hr.Settable Parameters: Date, time,auto power off, beep sound, sampling time, decimal point or comma decimal division, temperature unit, air speed unit, light level unit Thermocouple Type: K or J (optional)Storable/Recallable Readings: Maximum/minimum Operating Temperature: 0 to 50°C (32 to 122°F)Operating Relative Humidity: 0 to 85%Power: 6 “AA” Alkaline batteries (included) or an optional 9 Vdc AC adaptor DimensionsMeter: 135 H x 60 W x 33 mm D (5.31 x 2.36 x 1.30")Display: 52 L x 38 mm H (2.05 x 1.5") LCDPackage: 286 H x 251 W x 76 mm D (11.25 x 9.88 x 3")WeightMeter: 515 g (1.13 lb) Package: 35 oz (2.16 lb)memory card, hard plastic carrying case, 6 “AA” batteries and operator’s manual.Ordering Example: HHEM-SD1, handheld environmental meter with HHEM-SD1-SLP,sound probe.HHEM-SD1,meter with temperature/ humidity/air speed/light level probe (included).2 GB SD memorycardincluded.。
海瑞思智能密封性检测系统压力型说明书
直压检测仪说明书手册修订前言亲爱的客户:感谢您信赖我们的品牌,购买海瑞思直压检测仪,此仪器被设计的尽可能实用和稳定,我们深信它在多年的使用期间,能够带给您非常满意的体验。
为了更好的操作仪器,请仔细阅读说明书。
本说明书介绍的是海瑞思直压检测仪的安装、设置、产品功能、操作方法、保养、维修和操作注意事项等。
使用前请仔细阅读本说明书,并妥善保管。
安全注意事项本说明书记录了如何正确安全的使用直压检测仪的方法,并阐述了防止对操作者本人和他人造成危害及财产损失的内容。
不可进行本操作说明书记载以外的操作。
目录第一章、准备和安装 (1)1.开箱 (1)1.1准备工作 (1)1.2附件 (1)2.仪器组成 (1)2.1仪器正面构成 (1)2.2仪器背面构成 (2)3.仪器安装与连接 (2)3.1直压检测仪安装环境 (2)3.2仪器气源/电源连接 (2)3.3工装夹具与仪器的连接 (2)3.4控制接口的说明 (3)第二章、仪器界面操作说明 (6)1.总览 (6)1.1开机界面说明 (6)2.用户登录 (6)2.1如何进行用户登录? (6)2.2如何修改密码? (8)2.3如何注销用户? (9)2.4新建用户 (9)3.测前设置 (9)3.1显示方式 (10)3.2启动方式 (11)3.3语言选择 (12)3.4单位选择 (12)3.5精度选择 (13)3.6当前压力 (14)3.7仪表回零 (14)3.8正压 (14)3.9负压 (14)3.10压力 (14)4.程序参数 (14)4.1测试类型选择 (15)4.2测试方法选择 (16)4.3附加功能 (16)4.4测试时间参数 (17)4.5测试压力参数 (17)4.6外部输出状态 (18)4.7上方按钮说明 (19)4.8下方按钮说明 (20)5.系统设置 (21)5.1如何进入系统设置? (21)5.2输出 (22)5.3条码扫描参数 (22)5.4其他参数设置 (22)5.5通信状态 (22)5.6高级参数 (22)6.测试界面 (25)6.1数字测试界面 (25)6.2曲线测试界面 (26)7.历史记录 (27)8.条码扫描 (29)9.远程控制 (30)9.1 485modbus站号, (30)9.2 232modbus站号 (30)9.3结果上传 (30)9.4通信485串口/通信方式网口 (30)9.5 MES控制无效/MES控制有效 (30)9.6 IP地址 (30)10.工厂模式 (30)第三章、维护和保养 (31)1关于仪器保养 (31)1.1每天进行检测项目 (31)2异常故障及对策 (32)2.1 测试中NG多发时 (33)2.6 历史记录无法导出 (34)2.7仪器测试结果与实际泡水实验结果不对应 (34)第四章、快速编程 (35)1.IP防水等级简介和对应气压 (35)1.1IP防水等级简介 (35)1.2IPXX防水等级对应参考气压 (35)2.如何快速设置需要气压 (36)2.1待测产品有充气孔时 (36)2.2待测品无充气孔时 (36)3.如何快速选择测试方式 (37)4.如何快速设置测试程序 (37)4.1直接测试 (37)4.2间接测试 (37)4.3案例说明 (38)5.如何从历史记录中确定OK与NG判定标准 (40)5.1产品泄漏数值无标准,且不知产品是否OK与NG (40)5.2已知产品OK与NG,但不知道泄漏数值的 (40)第五章防水检测、密封检测知识小宝典 (44)1.各种压力的定义 (44)1.1相对压力和绝对压力 (44)1.2正压、负压、工程大气压、标准大气压 (45)1.3泄漏的机理 (45)2.测试原理 (45)2.1直接检测 (45)2.2间接检测 (46)3.测试流程与判断逻辑 (46)第六章关于SOP的一些建议 (48)1.什么是SOP? (48)2.SOP书写范例 (48)第一章、准备和安装1.开箱1.1准备工作a) 稳定且清洁的压缩气体,气压0.4Mpa-0.8Mpa ; b) 平稳并足够可靠的工作台; c) 稳定且无泄漏的工装治具; d) 电源要求AC 220V(±15%)、50HZ ; e)插好仪器的电源线,进出气气管、仪器与工装通讯的25PIN 排线;连接方式见图1-3;1.2附件2.仪器组成2.1仪器正面构成图1-1开始按钮/OK 指示灯防滑脚垫X42.2仪器背面构成图1-23.仪器安装与连接3.1直压检测仪安装环境a) 仪器工作环境温度,尽量保持在26C °±1°;b) 仪器摆放避开门口、通风口、空调口等;c) 仪器摆放桌面要稳定可靠,仪器周边不得摆放杂物;3.2仪器气源/电源连接a) 如图1-4所示,首先将仪器摆放到平整且稳定的桌面,将电源线一端插进仪器电源接口,另一端插入220V/50HZ 单相电源插座上;b) 将φ8的气管一端接到仪器进气接口,另一端接到工厂气源上; c) 将测试接口的气管接到工件或者模具上; d) 打开电源开关,等待2-3秒,仪器启动完成;3.3工装夹具与仪器的连接进气接口 电源接口电源开关 仪器锁RS232/485接口 25PIN I/O 接口测试口铭牌网络接口(选配) USB 接口图1-3图1-4工装与仪器连接步骤:a) 如图1-4,经过过滤后的工厂气源,分为两路,一路供给工装,一路供给仪器; b) 工装和仪器都是采用φ8的气管连接;c) 将仪器上φ4的出气管,连接到模具进气口; d) 用工装上25P 的排线连接到仪器上; e) 工装与仪器连接完成;3.4控制接口的说明接φ8的进气管 φ4测试管,连接模具 25PIN I/O 连接线 φ4测试气管 φ8进气管 电源线a)以太网接口:用于连接电脑(选配);b)USB接口:用于导出历史数据或者安装扫码枪;c)RS485接口:标准通信接口,可连接电脑,需要通讯协议,请联系销售工程师;d)25PIN I/O接口:海瑞思专用控制数据接口;外部输出:默认是24V直流输出,输出电流最大0.5A。
Omega PHH222 可移动 pH mV 温度测量仪说明书
Para hacer su pedido
N.º de modelo Descripción
PHH222
Medidor de pH/mV/temp. con RS232
Accesorios
N.º de modelo Descripción
HHWT-SD1_ATC Sonda de temperatura para PHH222
El modelo PHH222 se muestra en un tamaño inferior al real con
electrodo PHE-1411 opcional.
Especificaciones
Medición: pH/mV/temperatura Precisión: ±(pH 0,02 + 2 d) ±(0,5% + 2 d) Pantalla: LCD de doble función de 51 x 32 mm, dígitos de 15 mm (0.6") Rango: 0 a 14/-1999 a 1999 mV Resolución: pH 0,01/1 mV Impedancia de entrada: 1012 Ω Temperatura: Manual o automática de 0 a 65 °C Compensación: (sonda de temperatura) Salida de datos: RS232 Retención de datos: Sí Tiempo de muestreo: Aprox. 0,8 s Temperatura de funcionamiento: 0 a 50 °C (32 a 122 °F) Humedad de funcionamiento: HR inferior al 80% Recuperación de memoria: Máxima/mínima Alimentación: Batería de 9 V (incluida) Consumo de energía: Aprox. 8 mA Conexión del electrodo: BNC Dimensiones: 205 x 68 x 30 mm (8,1 x 2,7 x 1,2") Peso: 250 g (0,55 lb)
板卡功能测试说明WT-43#板功能说明如下
板卡功能测试说明WT-43#板功能说明如下:图1. WT-43#板形状图1. 功能设置开关图2. 拨码开关顶视图开关功能说明:向上拨功能允许,向下拨功能禁止表1.拨码开关功能说明开关序号开关功能简称拨码开关功能说明1 LFP Link fault pass through(LFP) 某一端口连接状态信息转发给另一端口,默认禁止(开关向下)2 Direct_Wire3 Fast_FWD开关2与开关3组合功能如下Direct_Wire Fast_FWD 组合功能描述 下 下 存储转发交换工作模式(默认)下 上 改进型快速交换工作模式 上 下 收发器模式上 上 带自动-更改-转发功能的收发器模式5 FX_Full 光口双工控制,默认为全双工(开关向下),开关向上为半双工6 X_EN 支持IEEE802.3X 功能控制,默认为支持(开关向下),开关向上为禁止 4 TP_Force7 Speed_ModeTP_Force Speed_Mode Duplex_Mode 功能描述下 下 下 100M/10M,全双工/半双工带自适应8 Duplex_Mode 下 下 上 100M/10M,半双工带自适应下 上 下 10M,全双工/半双工带自适应 下 上 上 10M,半双工带自适应 上 下 下 100M,全双工带自适应 上 下 上 100M,半双工带自适应 上 上 下10M,全双工带自适应 上 上 上 10M,半双工带自适应名词解释:存储转发交换工作模式(Store and forward switch mode )收发器接收完一个数据帧后立即转发该帧;改进型快速交换工作模式(Modified cut-through switch mode )收发器在收到首个64字节数据后开始转发该数据帧,此工作模式时必须强制电口为100M ; 收发器模式(Converter mode )收发器将数据直接转发,数据不进入缓存以实现最小延迟;带自动-更改-转发功能的收发器模式(Converter mode with auto-change-forward function ) 如果发现电口和光口速率不同则收发器,收发器将自动改变转发模式; 注:收发器模式中,收发器将立即转发IEEE802.3X 暂停帧;其它工作模式下,收发器不立即转发IEEE802.3X 暂停帧直到数据缓存已满才转发;更改收发器工作模式时,必须重新上电后才能进入更改后的工作模式。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
半球系列测试工装快速入门
北京合众思壮科技股份有限公司
工装简介
此工装是合众思壮为半球系列板卡自主设计的开发与测试平台。
1.1 正面介绍
测试工装正面由USB Client 、USB Host 及状态指示灯组成。
USB Client 接口:使用USB 连接线可连接PC ,控制接收机;
USB Host 接口:可直连U 盘,利用脚本可采集各种数据(20pin 设备不支持此
接口);
状态指示灯:显示各种状态信息,根据板卡不同具有显示差异。
1.2 背面介绍
背面由电源接口、四串口、电源开关及双天线接口组成。
电源接口:支持12V 接入
串口:具有四个标准RS232接口
天线接口:双TNC 接口,支持测向板卡
USB Client
USB Host
状态指示灯
电源接口 电源开关 TNC 天线接口
串口
1.3 工装内部介绍
工装内部具有3种接口,支持20PIN/34PIN/70PIN合众思壮公司GNSS接收板卡。
内部天线接口为:MCX
70PIN
34PIN 20PIN。