ANUSPLIN详细使用说明
USP泼尼松校正片说明书(中英文对照)

Certificate(证书)PREDNISONE TABLETS(泼尼松片)USP Catalog No.: 1559505USP Lot No。
: R031Y1(10 mg nominal prednisone content per tablet)(每片含泼尼松10mg)FOR DISSOLUTION PERFORMANCE VERIFICATION TEST (PVT)用于溶出性能确认实验Period of validity: This certificate of USP Prednisone Tablets Lot R031Y1 is valid through June 30th, 2017。
有效期:USP泼尼松片批号R031Y1的证书有效期到2017年6月30日The USP Prednisone Tablets RS is provided for use in the Performance Verification Test for USP Apparatus 1 and 2 with 1 liter vessels in the USP General Test Chapter on DISSOLUTION <711〉and DRUG RELEASE <724〉,APPARATUS SUITABILITY。
Store in a dry place. Store the tablets at controlled room temperature not exceeding 25°.USP泼尼松标准片用于采取USP中方法1和方法2对1升溶出杯,进行USP通用测试部分溶出(711)和释放(724)项目的性能能确认实验,药品贮藏在干燥,温度低于25℃环境中。
Dissolution Medium: We recommend preparing the medium as follows:Heat a suitable amount of water, while stirring gently, to about 41-45°. Filter under vacuum through a 0.45—μm-porosity filter into a suitable filtering flask equipped with a stirring device。
ANUSPLIN操作说明书

ANUSPLIN操作说明书ANUSPLIN操作说明书ANUSPLIN作为一个气象插值软件,网上有很多人找我问这些问题。
该软件与传统的界面式操作软件不同,所以刚开始接触的时候很多人感觉束手无策。
在此我写个说明文档,希望对刚开始接触学习的人有所帮助!如果仍有问题欢迎加QQ群466083085 进行交流。
数据的准备工作就不多了,气象数据利用SPSS整理成固定ASCII 格式,栅格数据在arcgis下面转换为ASCII格式。
具体操作可百度。
因个人水平有限,文档中有什么错误望指正!数据不论是地理坐标还是投影坐标都能运行,但是你的实验需要什么数据类型自行决定!软件的使用主要是调用splina.exe和lapgrd.exe两个程序。
接下来我先介绍splina的脚本如何编写这是一个完整的cmd文件示例。
下面我来解释一下每一行都代表什么东西。
图中可能说的不是很清楚,1000就是转换数据的转换系数后面还有验证文件输入名称,一般情况没有验证文件可以添加空格行保存后就可使用。
接下来我说说lapgrd的脚本编写,下面是一个输出单个表面的完整脚本样例下面是一个输出三个表面的脚本样例接下来解释一下每个参数的意义在做实验的时候必须注意的问题是splina的范围一定要比lapgrd 的范围略大原因在与栅格数据和矢量数据不能完全吻合,会产生误差,第一个命令设定好的范围栅格数据不能确保在范围之内执行命令就会报错。
软件运行其实很简单,你只要写好cmd脚本文件就可以调用你的软件了。
Win+R键打开运行输入cmd 即可打开命令提示符窗口这其实是个DOS界面,首先你要进入你cmd文件、数据文件、exe程序的路径。
如图所示,我进入了文件的所在路径。
然后输入splina<气温.cmd>temp.log 后按回车即可运行splina.exe程序。
splina代表你的splina.exe程序气温.cmd代表写的cmd脚本名称temp.log是日志文件,你在哪出错了或者你每一步输入的命令是做什么的你都可以在这里面进行查看。
(精选)人前心钠肽ProANPelisa试剂盒使用说明书

人前心钠肽(Pro-ANP)elisa试剂盒使用说明书Elisa kit规格:48孔配置/96孔配置标准品稀释液:1.5ml×1瓶酶标试剂:3 ml×1瓶(48)/6 ml×1瓶(96)【人前心钠肽(Pro-ANP) elisa试剂盒】本试剂仅供研究使用计算:以标准物的浓度为横坐标,OD值为纵坐标,在坐标纸上绘出标准曲线,根据样品的OD值由标准曲线查出相应的浓度;再乘以稀释倍数;或用标准物的浓度与OD值计算出标准曲线的直线回归方程式,将样品的OD值代入方程式,计算出样品浓度,再乘以稀释倍数,即为样品的实际浓度。
试剂盒组成:封板膜:2片(48)/2片(96)说明书:1份密封袋:1个标准品:2700ng/L 0.5ml×1瓶0.5ml×1瓶2-8℃保存酶标包被板: 1×48 1×96 2-8℃保存样品稀释液: 3ml×1瓶 6 ml×1瓶2-8℃保存显色剂A液: 3ml×1瓶 6 ml×1瓶2-8℃保存显色剂B液: 3ml×1瓶 6 ml×1瓶2-8℃保存终止液: 3ml×1瓶6ml×1瓶2-8℃保存浓缩洗涤液:(20ml×20倍)×1瓶(20ml×30倍)×1瓶2-8℃保存实验原理:本试剂盒应用双抗体夹心法测定标本中人前心钠肽(Pro-ANP) 水平。
用纯化的人前心钠肽(Pro-ANP) 抗体包被微孔板,制成固相抗体,往包被单抗的微孔中依次加入前心钠肽(Pro-ANP) ,再与HRP标记的前心钠肽(Pro-ANP) 抗体结合,形成抗体-抗原-酶标抗体复合物,经过彻底洗涤后加底物TMB显色。
TMB在HRP酶的催化下转化成蓝色,并在酸的作用下转化成最终的黄色。
颜色的深浅和样品中的前心钠肽(Pro-ANP) 呈正相关。
磷酸苯丙哌林分散片(法思特)的说明书

磷酸苯丙哌林分散片(法思特)的说明书呼吸道疾病在我们日常生活中是最常见的一种疾病了,就因为它的常见,所以很多人都不去重视,总是认为过两天就自己好了。
事实证明,呼吸道疾病不但不会自愈,还会引起其他疾病,磷酸苯丙哌林分散片(法思特)在防止呼吸道疾病恶化上起到了至关重要的作用,接下来做个具体的了解。
【药品名称】通用名称:磷酸苯丙哌林分散片商品名称:磷酸苯丙哌林分散片(法思特)【规格型号】20mg*36s【用法用量】口服。
吞服或用少量水溶解后服用,成人一次20~40mg,一日3次,或遵医嘱。
【不良反应】服药后可出现一过性口、咽部发麻感觉。
此外尚有乏力、头晕、上腹不适及皮疹等不良反应。
【禁忌】对本品过敏者禁用。
【注意事项】1.服药期间若出现皮疹,应停药。
2.本品仅具镇咳作用,如用药一周症状无好转应咨询医生。
【有效期】0 月【批准文号】国药准字H20000315【生产企业】太阳石(唐山)药业有限公司【药品类别】镇咳药【主要成份】磷酸苯丙哌林。
其化学名称为:1-[2-(2-苄基苯氧基)-1-甲基乙基]哌啶磷酸盐。
【性状】本品为白色或类白色片【剂型】片剂【药理作用】本品为非成瘾性镇咳药,能抑制咳嗽中枢,也能抑制肺及胸膜牵张感受器引起的肺- 迷走神经反射,且能舒张支气管平滑肌。
即兼有中枢性和末梢性双重镇咳作用机制。
【药代动力学】本品口服易吸收,服药后10~20分钟即生效,镇咳作用可维持4~7小时。
【孕妇及哺乳期妇女用药】本品在妊娠期间的用药安全性尚未确定,亦未见本品在乳汁中排出的报道,故孕妇应慎用。
【儿童用药】儿童用药疗效和安全性尚未确定应遵医嘱【药物相互作用】尚不明确。
【贮藏】遮光,密闭保存以上内容充分介绍了关于磷酸苯丙哌林分散片(法思特)的使用方法和药效,希望能对您带来帮助。
患上呼吸系统疾病是很痛苦的一件事,人们呼吸不畅就会造成一系列的危害,因此及时使用磷酸苯丙哌林分散片(法思特)进行治疗是非常有必要的,它能有效的缓解和治疗您的呼吸系统疾病,药到病除。
EASYspin Plus大量组织细胞RNA快速提取试剂盒操作方法及步骤说明书-5页精选文档

EASYspin Plus大量组织/细胞RNA快速提取试剂盒目录号:RN41目录编号包装单位RN4101 10次❖适用范围:适用于快速提取动物细胞和易裂解动物组织总RNA,使用独有基因组DNA清除柱技术确保有效清除gDNA残留,不需要使用DNase消化,RNA可直接用于PCR,荧光定量PCR.。
❖试剂盒组成、储存、稳定性:试剂盒组成保存10次裂解液RLT Plus 室温100 ml去蛋白液RW1 室温120 ml漂洗液RW 室温25 ml X 2第一次使用前按说明加指定量乙醇70%乙醇室温15ml X 2第一次使用前按说明加指定量乙醇RNase-free H2O 室温10 ml基因组DNA清除柱和收集管室温10套RNase-free吸附柱RA和收集管室温10套本试剂盒在室温储存6个月不影响使用效果。
储存事项:1.所有的溶液应该是澄清的,如果环境温度低时溶液可能形成沉淀,此时不应该直接使用,可在37℃水浴加热几分钟,即可恢复澄清。
2.不合适的储存于低温(4℃或者-20℃)会造成溶液沉淀,影响使用效果,因此运输和储存均在室温下(15℃-25℃)进行。
3.避免试剂长时间暴露于空气中产生挥发、氧化、PH值变化,各溶液使用后应及时盖紧盖子。
❖注意事项1.所有的离心步骤均可在室温完成,使用可容纳50ml 离心管的离心机。
2.样品处理量绝对不要超过基因组吸附柱DA和和RNA吸附柱RA处理能力,否则造成DNA残留或者产量降低。
不同组织细胞种类RNA/DNA相差极大,例如胸腺脾脏DNA含量丰富,超过100mg就会超过柱子处理能力。
COS细胞RNA含量丰富,超过6x107细胞就会超过柱子吸附能力。
所以开始摸索实验条件时,如果不清楚样品DNA/RNA含量时宁可使用较少的样品处理量,如细胞不超过6x107,组织不超过200mg。
将来根据样品试验情况增加或者减少处理量。
3.裂解液RLT Plus 和去蛋白液RW1中含有刺激性化合物,操作时要戴乳胶手套,避免沾染皮肤,眼睛和衣服。
ANUSPLIN实例

注:以上经纬度数据为ALBERS投影,单位为米
四、Anusplin模型选择
• Anusplin在日志文件中提供了一系列用于判 断误差来源和插值质量的统计参数。包括: • 有效数量估计Signal(信号自由度)、剩余自 由度Error、光滑参数RHO、GCV、期望真 实均方误差MSE、最大似然法误差GML、 均方残差MSR、方差估计VAR及其平方根。 由这些来选择最佳模型。
与SPLINA功能类似,站点数最多可达 10000个站点。
SELNOT
为SPLINB选择初始节点。
ADDNOT
添加数据节点。
说明:
DELNOT
删除数据节点
GCVGML
对拟合表面计算GCV或GML误差,用 于数据检查或定位。
LAPPNT
计算预测值或贝叶斯标准误差估计的点 文件。
生成拟合曲面或贝叶斯标准误差曲面。
covanusplin流程1执行splina或splinb命令表面系数文件协变量误差信息由第一步生成的插值表面标准误差表面得到anusplin流程2执行lapgrd命令anusplinanusplin需要将以固定形式存储的气象要素数据进行处理成程序要求的标准格式生成文本文件
专业气候数据空间插值软件 Anusplin简介
四、Anusplin模型选择
因此:最佳模型判断标准:
• (1)GCV或GML最小、 • (2)信噪比SNR(信号自由度与剩余自由 度之比)最小、 • (3)信号自由度小于站点的一半、 • (4)模型成功率判断中无*表示。
五、Anusplin应用示例
• (1)数据准备:将数据准备成如下格式(本 例中在spss中整理,也可在其他软件中完成)
五、Anusplin应用示例
人前心钠肽ProANPelisa试剂盒使用说明书

人前心钠肽(Pro-ANP)elisa试剂盒使用说明书Elisa kit规格:48孔配置/96孔配置标准品稀释液:1.5ml×1瓶酶标试剂:3 ml×1瓶(48)/6 ml×1瓶(96)【人前心钠肽(Pro-ANP) elisa试剂盒】本试剂仅供研究使用计算:以标准物的浓度为横坐标,OD值为纵坐标,在坐标纸上绘出标准曲线,根据样品的OD值由标准曲线查出相应的浓度;再乘以稀释倍数;或用标准物的浓度与OD值计算出标准曲线的直线回归方程式,将样品的OD值代入方程式,计算出样品浓度,再乘以稀释倍数,即为样品的实际浓度。
试剂盒组成:封板膜:2片(48)/2片(96)说明书:1份密封袋:1个标准品:2700ng/L 0.5ml×1瓶0.5ml×1瓶2-8℃保存酶标包被板: 1×48 1×96 2-8℃保存样品稀释液: 3ml×1瓶 6 ml×1瓶2-8℃保存显色剂A液: 3ml×1瓶 6 ml×1瓶2-8℃保存显色剂B液: 3ml×1瓶 6 ml×1瓶2-8℃保存终止液: 3ml×1瓶6ml×1瓶2-8℃保存浓缩洗涤液:(20ml×20倍)×1瓶(20ml×30倍)×1瓶2-8℃保存实验原理:本试剂盒应用双抗体夹心法测定标本中人前心钠肽(Pro-ANP) 水平。
用纯化的人前心钠肽(Pro-ANP) 抗体包被微孔板,制成固相抗体,往包被单抗的微孔中依次加入前心钠肽(Pro-ANP) ,再与HRP标记的前心钠肽(Pro-ANP) 抗体结合,形成抗体-抗原-酶标抗体复合物,经过彻底洗涤后加底物TMB显色。
TMB在HRP酶的催化下转化成蓝色,并在酸的作用下转化成最终的黄色。
颜色的深浅和样品中的前心钠肽(Pro-ANP) 呈正相关。
复方阿司匹林牛磺酸胶囊使用说明书

复方阿司匹林牛磺酸胶囊使用说明书
请仔细阅读说明书并在医师指导下使用复方阿司匹林牛磺酸胶囊使用说明书
【药品名称】
通用名称:复方阿司匹林牛磺酸胶囊
汉语拼音:Fufang A‘sipilin Niuhuangsuan Jiaonang
【性状】本品为胶囊剂,内容物为绿、红、黄、白色类圆形微丸。
【适应症】
适用于预防和治疗缺血性脑血管疾病,如短暂脑缺血性发作、脑缺血性中风和脑动脉硬化。
【用法用量】口服:常用量:一次1粒,一日3次,连续服用一个月为一个疗程,停药一周可继续服用下一个疗程,切勿随意增加剂量。
【不良反应】未见明显的毒副反应。
【注意事项】溃疡病及有出血倾向的患者慎用;高空作业者和驾驶员慎用。
严格按说明书的剂量服用。
【孕妇及哺乳期妇女用药】尚不明确
【药物相互作用】尚不明确
【药理毒理】有较强的抗血小板聚集作用,有较强的抗实验性血栓形成的作用,对心血管系统、呼吸系统、神经系统均无明显的副作用,长期毒性试验未发现毒性反应,小鼠口服LD50为1.9g/kg体重, 小鼠腹腔注射LD50为1.03g/kg体重。
【贮藏】避光、密封,干燥处保存。
【包装】每板10粒,每盒2板;药品铝塑泡罩包装。
【有效期】18个月
说明书字数:580。
安思利普使用说明

安思利普使用说明
安思利普治疗仪使用起来非常简单,只需要8个步骤就可以进行治疗。
您可以仔细阅读用户手册进行操作。
步骤1:取四个海绵贴各粘贴在耳夹电极处。
步骤2:将导电液均匀滴在海绵贴上,使其完全润湿。
(如在空调、抽湿等环境使用该产品时,请确保耳夹棉垫保持湿润工作,以免影响治疗效果和进度。
)
步骤3:将耳夹线接口平衡插入主机【耳夹线插孔】。
步骤4:将耳夹轻轻夹在耳垂处(耳夹不分左右)。
步骤5:转动【开关机旋钮】开机。
步骤6:按【时间/TIME】键一次,进入60分钟时间模式,显示屏显示【59:59】字样并倒计时;再按则进入20分钟模式。
步骤7:按【UP/DOWN】键一次,进入工作状态。
调节强度,直至头部体验到舒适的感觉。
步骤8:接受治疗指导时间结束,时间结束机器会关闭输出;过程中不需要进行其他操作。
基于分布式时变增益水文模型和CN05

第45卷第3期人民珠江 2024年3月 PEARLRIVERhttp://www.renminzhujiang.cnDOI:10 3969/j issn 1001 9235 2024 03 003基金项目:国家自然科学基金资助项目(42371021、52109036);河海大学水灾害防御全国重点实验室“一带一路”水与可持续发展科技基金面上项目(2022491111、2021490611);水利部水文气象灾害机理与预警重点实验室开放基金(HYMED202203、HYMED202210)收稿日期:2023-07-08作者简介:钟奇(1999—),男,硕士研究生,主要从事水文水资源研究。
E-mail:zhongqi_zzq@163.com通信作者:付晓雷(1986—),男,教授,主要从事土壤水热数据同化、水文预报研究。
E-mail:fuxiaolei518@yzu.edu.cn钟奇,付晓雷,蒋晓蕾,等.基于分布式时变增益水文模型和CN05.1降水数据的赣江流域径流模拟研究[J].人民珠江,2024,45(3):18-29,108.基于分布式时变增益水文模型和CN05.1降水数据的赣江流域径流模拟研究钟 奇1,付晓雷1,2,3,蒋晓蕾1,2,章雨晨1,胡乐怡1,章丽萍1(1.扬州大学水利科学与工程学院,江苏 扬州 225009;2.水利部水文气象灾害机理与预警重点实验室,南京信息工程大学,江苏 南京 210044;3.河海大学水灾害防御全国重点实验室,江苏 南京 210098)摘要:水文模型是径流模拟的重要手段,降水是水文循环的重要组成部分,模型的选择和降水数据的质量对流域径流模拟都具有重要意义。
以赣江流域为研究区域,通过对比CN05.1降水数据与站点线性插值降水数据,分析CN05.1降水数据的可靠性,评估基于分布式时变增益水文模型(DTVGM)和CN05.1降水数据在赣江流域径流模拟的适用性。
研究表明:①CN05.1降水和站点插值降水多年月平均降水年内变化过程类似,空间分布相关性很高,R均值为0.90,CN05.1日降水与站点插值日降水相关性较高,RMSE均小于等于7.52mm,R均大于等于0.81;②基于CN05.1降水和站点插值降水数据模拟了赣江流域新田等6个水文站1961—2009年的流量,模拟流量在多数大流量处大于实测流量,表明模型对于大流量的模拟存在高估现象;③无论是日径流还是月径流,基于CN05.1降水数据的径流模拟精度均较高,且月径流模拟要优于日径流。
气象数据集说明文档.doc

气象数据集说明文档1.数据集信息数据集中文名称:中国地面降水月值0.5°×0.5°格点数据集数据集代码:SURF_CLI_CHN_PRE_MON_GRID_0.5数据集版本:V2.0数据集建立时间:201208012.数据来源:该数据集的数据来源包括2个部分:由国家气象信息中心基础资料专项收集、整理的1961年至最新的全国国家级台站(基本、基准和一般站)的降水月值资料;由GTOPO30数据(分辨率为0.05°×0.05°)经过重采样生产的中国陆地0.5°×0.5°的数字高程模型DEM。
3.数据集实体3.1.数据集实体内容说明3.1.1.数据集实体文件名称:中国地面降水月值0.5°×0.5°格点数据集文件命名由数据集代码(SURF_CLI_CHN_PRE_MON_GRID_0.5)、年份、月份标识(YYYYMM)组成。
具体形式:SURF_CLI_CHN_PRE_MON_GRID_0.5 -YYYYMM.TXT3.1.2.数据集实体文件的内容描述:数据集实体包括1961年1月至最新的逐月数据文件,每个文件中包括的前6行为头文件信息,其中:第一行"ncols 128":表示实体数据有128列;第二行"nrows 72"表示实体数据有72行;第三行"xllcorner 72"表示实体数据左下方对应最小经度是72°E;第四行"yllcorner 18"表示实体数据左下方对应最小纬度是18°N;第五行"cellsize 0.5"表示网格是0.5°×0.5°的;第六行"NODATA_value -9999.0"表示中国区域以外的值用-9999.0表示。
气象数据集说明文档

气象数据集说明文档1.数据集信息数据集中文名称:中国地面气温月值0.5°×0.5°格点数据集数据集代码:SURF_CLI_CHN_TEM_MON_GRID_0.5数据集版本:V2.0数据集建立时间:201208012.数据来源:该数据集的数据来源包括2个部分:由国家气象信息中心基础资料专项收集、整理的1961至最新的全国国家级台站(基本、基准和一般站)的气温月值资料;由GTOPO30数据(分辨率为0.05°×0.05°)经过重采样生成的中国陆地0.5°×0.5°的数字高程模型DEM。
3.数据集实体3.1.数据集实体内容说明3.1.1.数据集实体文件名称:中国地面气温月值0.5°×0.5°格点数据集文件命名由数据集代码(SURF_CLI_CHN_TEM_MON_GRID_0.5)、要素标识、年份、月份标识(YYYYMM)组成。
具体形式:SURF_CLI_CHN_TEM_MON_GRID_0.5-MEAN-YYYYMM.TXTSURF_CLI_CHN_TEM_MON_GRID_0.5-MAX-YYYYMM.TXTSURF_CLI_CHN_TEM_MON_GRID_0.5-MIN-YYYYMM.TXT3.1.2.数据集实体文件的内容描述:数据集实体包括1961年1月至最新的逐月数据文件,每个文件中包括的前6行为头文件信息,其中:第一行"ncols 128":表示实体数据有128列;第二行"nrows 72"表示实体数据有72行;第三行"xllcorner 72"表示实体数据左下方对应最小经度是72°E;第四行"yllcorner 18"表示实体数据左下方对应最小纬度是18°N;第五行"cellsize 0.5"表示网格是0.5°×0.5°的;第六行"NODATA_value -99.00000"表示中国区域以外的值用-99.0表示。
安 friendship 医疗气体接叉 британ式窄型兼容模式指南说明书

Installation and Maintenance Manual Medical Gas OutletBritish Standard Slim Style Compatible0123ContentsProduct Description 3 Cleaning and Lubricating 3 Inspection and Testing 4 Installation and Dimensions 4-6 Console Mounted 5 Surface Mounted 6 Preventive Maintenance 7 Monthly 7 Annually 7 Gas Latch Valve Assembly 8 Vacuum Latch Valve Assembly 9 AGSS Latch Valve Assembly 10 Disassembly of the Check Valve Body Assembly 10 Reassembly of the Check Valve Body Assembly 10 AGSS Flow Control Adjustment 11 Reference Part Numbers 11 Rough-in Assembly 12 Removal of Internal Components 12 Reinstallation of Internal Components 12 Model Numbers 13 Console Mounted 13 Surface Mounted 13 Gas Indexing 14 Replacement Components 15-17 Gas and Vacuum Replacement Components 15 AGSS Replacement Components 16 Rough-In Assembly 172Amico Mobility Solutions CorporationProduct DescriptionThe Amico Medical Gas British Outlet Slim Style is composed of two separate modules: the “Rough-in Assembly”and the “Latch Valve Assembly”. The “Rough-in Assembly” consists of a brass machined body that incorporates a spring loaded check assembly except for Vacuum and AGSS. The copper pipe is SILVER brazed into the body and flared to 12 mm inside diameter for external pipeline connections. The brass body and pipe assembly are inserted into a gas specific plate. The “Rough-in Assembly” has a colour coded label on the front plate and copper pipe, sothat the installer can easily identify the gas that the copper pipe should be connected to. The “Rough-in Assembly” incorporates a check valve that allows the “Latch Valve Assembly” to be removed for service, without requiring the pipeline to be shut down. Vacuum and AGSS rough-ins include a pressure plug for testing and servicing purposes. The “Rough-in Assembly” has a DUAL pin gas specific indexing arrangement to prevent the wrong “Latch Valve Assembly” from being plugged into the “Rough-in Assembly” (see page 17).The “Latch Valve Assembly” is manufactured with a gas specific housing which accepts, retains and releases the probe, indexed on the back side to match gas specific indexing of the “Rough-in Assembly”.CAUTION: DO NOT over tighten the Latch Valve mounting screws! Distortion of the Latch Valve can occur.Outlets are available for Oxygen, medical air, surgical air, nitrous oxide, medical vacuum and anesthetic gas scavenging system. These are designed in accordance with HTM 02-01 and ISO 9170.This device has been manufactured to conform to the standards, specifications and operating procedures stated in this manual when installed, inspected, operated, maintained, and serviced in accordance with these instructions.The user of the device shall have the sole responsibility for any malfunction which results from improper installation, use, maintenance, alteration or modification.W ARNING: Keep all components dry and clean during installation. DO NOT alter or modify this device or any of its components in any way. Store in normal working and environmental conditions. Adverse environmental conditions, harsh abrasives or chemicals will cause damage to the unit.Cleaning and LubricatingThe Amico British Slim Style Outlets are factory cleaned for Oxygen service. Exposed surfaces of the Outlet maybe cleaned with a mild detergent solution or wiped with a disinfectant commonly used in patient rooms, which is compatible with plastic, anodized aluminum and die cast zinc. Lubricate elastomer seals sparingly with a lubricant that is Oxygen compatible. DO NOT USE OIL. 3Inspection and TestingPressure drops across the Amico Medical Gas British Outlet Slim Style shall comply with ISO 9170 Standards.* Absolute pressureAGSS Requirements for flow and pressure drop across terminal units with probe inserted complies with ISO 9170Standards.The Amico British Slim Style Outlets meet and exceed the requirements at the time of manufacture. However piping source capacity, sizing and restrictions my prevent outlets form attaining these values.Installation and DimensionsThe Amico British Slim Style Outlet should be mounted at a height of between 900 mm and 1400 mm above finished floor level and not less than 200 mm from any obstruction.Where more than one Outlet unit is to be mounted in one location, these should be mounted at the following spacing:• Two Outlet units - 150 mm centres• Three or more Outlets units - 135 mm centresOutlet units mounted in a horizontal array shall be installed in the following sequence when viewed from the front, left to right:O₂; N₂O; 50% O₂ / 50% N₂O; Medical Air, Surgical Air, Vacuum; AGSSPlease refer to HTM 02-01CAUTION: DO NOT braze rough-ins with front latch installed. Must use wet rag when brazing since the heat could damage the secondary check valve, seal, and other installed components. Use only mild soap-basedsolution for leak testing.4Amico Mobility Solutions Corporation 5Console MountedInch[mm]6 Amico Mobility Solutions CorporationSurface MountedInch[mm]Preventative MaintenanceRegular inspection and maintenance of the Outlets will prolong its life and reduce the possibility of sudden, inconvenient component failures. The use of damaged probes or faulty equipment may require further maintenance.Outlets should be subjected to regular inspection and testing as follows:Monthlya. Visually inspect the Outlet for signs of damage.b. Check to see if the Front Latch Assembly (2nd Fix) operates smoothly with the gas specific probe.c. If there is any disagreement with the operation of the Front Latch Assembly (2nd Fix), remove the unit for closerinspection/repair/replacement if necessary.Annuallya. Remove Trim Plate and clean debris from the mounting box.b. Remove Front Latch Assembly (2nd Fix) and inspect the barrel for any damage.c. Inspect the Rough-in Assembly (1st Fix) for any damage. If damaged or leaking, replace components.d. Test Front Latch Assembly (2nd Fix) for correct operation (connection and disconnection of the probe) using ablank probe. 7Gas Latch Valve Assembly1. Unscrew the two Surface Box Cover screws (1), and remove the Surface Box Cover (2) for Surface Mount Outlets, orpry off Trim Ring (3) for Console Mount Outlets with a flat screw driver.2. Unscrew the two Retaining screws (5) until the Latch Valve Assembly (4) can be removed from the Outlet.3. Remove the two Retaining washer screws (11), and remove the Retaining washer (10).4. Remove the Gas Connector (8).5. Remove the Body Seal (6), and the Poppet O-Ring (9), then the Poppet (7) from the front of the Gas Connector (8).Inspect the items for wear or damage and replace if needed.6. Re-install all internal components into the Gas Connector (8). Check that the Poppet (7), Poppet O-Ring (9), andBody Seal (6) are in place. Re-install the round Retaining washer (10) and secure with two Retaining washer screws(11), do not over tighten.7. Re-install the Latch Valve Assembly into the outlet. Coat the Gas Connector (8) with a thin coat of Oxygencompatible lubricant to aid insertion. Tighten down the Retaining screws (5), DO NOT over tighten, as this could damage the Latch Valve Assembly.8. Re-install Surface Box Cover (2), install Surface Box screws (1) and tighten down (DO NOT OVER TIGHTEN) or re-install Trim Ring (3).9. Connect gas specific adapter into the outlet. The connection should be smooth and the adapter should lock andremain in place allowing gas to flow. If not, replace the entire Latch Valve Assembly (4).8Amico Mobility Solutions CorporationNOTE:removing the Latch Valve Assembly.1. Unscrew the two Surface Box Cover screws (1), and remove the Surface Box Cover (2), for Surface Mount Outlets orpry off Trim Ring (3) for Console Mount Outlets with a flat screw driver.2. Unscrew the two Retaining screws (5) until the Latch Valve Assembly (4) can be removed from the Outlet.3. Remove the Primary Vacuum Spring (12) and inspect for damage, replace if needed.4. Remove the two Retaining washer screws (11), and remove the Retaining washer (10).5. Remove the Gas Connector (8).6. Remove the Body Seal (6), and the Poppet O-Ring (9), then the Poppet (7) from the front of the Gas Connector (8).Inspect the items for wear or damage and replace if needed.7. Re-install all internal components into the Gas Connector (8). Check that the Poppet (7), Poppet O-Ring (9), andBody Seal (6) are in place. Re-install the round Retaining washer (10) and secure with two Retaining washer screws(11), do not over tighten.8. Re-install the Primary Vacuum Spring (12).9. Re-install the Latch Valve Assembly into the outlet. Coat the Gas Connector (8) with a thin coat of Oxygencompatible lubricant to aid insertion. Tighten down the Retaining screws (5), DO NOT over tighten, as this could damage the Latch Valve Assembly.10. Re-install Surface Box Cover (2), install Surface Box screws (1) and tighten down (DO NOT OVER TIGHTEN) or re-install Trim Ring (3).11. Connect gas specific adapter into the outlet. The connection should be smooth and the adapter should lock andremain in place allowing gas to flow. If not, replace the entire Latch Valve Assembly (4). 91. Unscrew the two Surface box Cover screws (1), and remove the Surface Box Cover (2), for Surface Mount Outlets orpry off Trim ring (3) for Console Mount Outlets with a flat screw driver.2. Unscrew the two Retaining screws (5) until the “Latch Valve Assembly” (4) can be removed from the Outlet.3. After removing the “Latch Valve Assembly” (4) from the Outlet, you can then pull the Check Valve Body Assemblyfrom the back side of the “Latch Valve Assembly” (4). Remove the Check Valve Body Seals (10 & 11) and check for any abnormal wear or damage and replace if needed. Coat the O-Ring with a thin coat of Oxygen compatible lubricant.4. Disassembly of the Check Valve Body AssemblyHold the Check Valve Assembly in one hand, and push down the Check Valve (6) with your thumb of the same hand, compressing the Check Valve Spring (9). Remove the Check Valve O-Ring (13). Release the Check Valve (6) slowly; The Check Valve Body Assembly will fall apart. Inspect parts for abnormal damage or wear and replace if needed.5. Reassembly of the Check Valve Body AssemblyRe-install the Check Valve Spring (9) onto the Check Valve (6), and then insert them into the Check Valve Body (12).Again, hold the Check Valve Body Assembly in one hand, and push down the Check Valve (6) with your thumb of the same hand, compressing the Check Valve Spring (9). Before re-installing the Check Valve O-Ring (13), coat the O-Ring with a thin coat of Oxygen compatible lubricant.6. Insert the Check Valve Body Assembly into the back of the “Latch Valve Assembly”.7. Re-install the “Latch Valve Assembly” into the outlet. Coat the outer portion of the Check Valve Body Assemblywith a thin coat of Oxygen compatible lubricant, to aid insertion. Tighten down Retaining Screws (5). DO NOT over tighten, as this could damage the Latch Valve.8. Re-install Surface Box Cover (2), install Surface Box screws (1) and tighten down (DO NOT OVER TIGHTEN) or re-install Trim Ring (3).9. Connect gas specific adapter into the outlet. The connection should be smooth and the adapter should remain inplace allowing gas to flow. If not, replace the entire Latch Valve Assembly (4).10Amico Mobility Solutions Corporation 11AGSS Flow Control Adjustment1. Insert a 3 mm Allen key into the front of the Check Valve.2. Adjust the Flow Control Screw to desired setting.Reference Part Numbers O-BSQ-CON-AGS O-BSQ-SUR-AGSA.G.S.S.Threaded Nose British Standard A.G.S.S.A.G.S.S.THREADED NOSEBritish Standard A.G.S.S.Rough-in AssemblyInside the “Rough-in Assembly” is a secondary check valve whose function is to shut off gas flow when the “Latch Valve Assembly “ is removed. This seal O-Ring also prevents leakage around the Latch Valve connector. As the secondary seal is only a static seal, it will rarely need replacement. However, if the seal O-Ring does need replacement, follow the following procedure:NOTE:Suction inlets (Vacuum and AGSS) are not supplied with Secondary Check Valve. The Secondary Check Valve (2) and Secondary Check Valve Spring (3) are not required.1. Ensure that no pressure exists in the line by depressing the secondary check (2).2. Removal of Internal ComponentsDepress the Secondary Check Valve (2), with a dull screw driver (prevents damage on the Check Valve), at the same time pry out the Secondary Seal O-Ring (1), with a small screw driver. After the Secondary Seal O-Ring (1) is out.The Secondary Check Valve (2) and Secondary Check Valve Spring (3) are no longer locked in place and can be easily removed. Inspect all components for abnormal wear and replace.3. Reinstallation of Internal ComponentsInstall the Secondary Check Valve Spring (3) to the back side for the Secondary Check Valve (2). Then insert into the Rough-in Body (4). Insert Secondary Seal O-Ring (1), while depressing the Secondary Check Valve (2).4. Turn on the pressure and check for leaks. Re-install the “Latch Valve Assembly” and perform inspection and test.12Amico Mobility Solutions CorporationModel Numbers 13Gas IndexingAs seen from the front of the“Rough-in Assemblies”14Amico Mobility Solutions CorporationAbove parts with an * are found in repair kit: O-RK-LVA-BSQ, not sold individually. 15AGSS Replacement ComponentsAbove parts with an * are found in repair kit: O-RK-LVA-BSQSL-AGS, not sold individually. 16Amico Mobility Solutions Corporation 17Rough-in AssemblyNOTE:Suction inlets (Vacuum and AGSS) are not supplied with Secondary Check Valves. The Secondary Check Valve (2) andSecondary Check Valve Spring (3) are not required.Above parts with an * are found in repair kit: O-RK-BAK-BSQSL, not sold individually.Authorized Representative:AJW Technology Consulting GmbHKönigsallee 10640215 DüsseldorfTel: +49 (0) 211 3013 2232Amico Mobility Solutions Corporation122-B East Beaver Creek Road, Richmond Hill, ON L4B 1G6, Canada 600 Prime Place, Hauppauge, NY 11788, USAToll Free Telephone: 1.877.462.6426 | Telephone: 905.764.0800 | Fax: 905.764.0862 Email:**************|ACP-IM-MEDICAL-GAS-OUTLETS-BRITISH-STANDARD-SLIM 07.12.2022。
胰岛素注射液说明介绍模板之欧阳理创编

胰岛素注射液说明书【药品名称】通用名:胰岛素注射液英文名:Insulin Injection汉语拼音:Yidaosu Zhusheye【成份】1. 本品主要成分为:胰岛素(猪或牛)的灭菌水溶液。
每l00ml中含甘油l.4-1.8g与苯酚0.25g。
2. 辅料:甘油、苯酚、注射用水。
【性状】本品为无色或几乎无色的澄明液体。
【适应症】1.Ⅰ型糖尿病。
2.Ⅱ型糖尿病有严重感染、外伤、大手术等严重应激情况,以及合并心、脑血管并发症、肾脏或视网膜病变等。
3.糖尿病酮症酸中毒、高血糖非酮症性高渗性昏迷。
4.长病程Ⅱ型糖尿病血浆胰岛素水平确实较低,经合理饮食、体力活动和口服降糖药治疗控制不满意者,Ⅱ型糖尿病具有口服降糖药禁忌,如妊娠、哺乳等。
5.成年或老年糖尿病病人发病急、体重显著减轻伴明显消瘦。
6.妊娠糖尿病。
7.继发于严重胰腺疾病的糖尿病。
8.对严重营养不良、消瘦、顽固性妊娠呕吐、肝硬变初期可同时静脉摘注葡萄糖和小剂量胰岛素,以促进组织利用葡萄糖。
【规格】l0ml:400单位。
【用法用量】l.皮下注射一般每日三次,餐前15-30分钟注射,必要时睡前加注一次小量。
剂量根据病情、血糖、尿糖由小剂量(视体重等因素每次2-4单位)开始,逐步调整。
Ⅰ型糖尿病患者每日胰岛素需用总量多介于每公斤体重0.5-1单位,根据血糖监测结果调整。
Ⅱ型糖尿病患者每日需用总量变化较大,在无急性并发症情况下,敏感者每日仅需5-l0单位,一般约20单位,肥胖、对胰岛素敏感性较差者需要量可明显增加。
在有急性并发症(感染、创伤、手术等)情况,对Ⅰ型及Ⅱ型糖糖尿病患者,应每4-6小时注射一次,剂量根据病情变化及血糖监测结果调整。
2.静脉注射主要用于糖尿病酮症酸中毒、高血糖高渗性昏迷的治疗。
可静脉持续滴入每小时成人4-6单位,小儿按每小时体重0.1单位/kg,根据血糖变化调整剂量;也可首次静注l0单位加肌内注射4-6单位,根据血糖变化调整。
病情较重者,可先静脉注射10单位,继之以静脉滴注,当血糖下降到13.9mmol/L(250mg/ml)以下时,胰岛素剂量及注射频率随之减少。
微量注射泵

避光使用
Company Logo
二、微量输液泵的基本结构
Company Logo
微量注射泵
Company Logo
三、微量注射泵的基本操作规范
一、操作准备
1.护士自身准备 衣帽整洁、洗手、戴口罩 2.用物准备 治疗盘(棉签缸、无菌溶液、标签、碘伏、污物 缸、弯盘、50ml注射器、延长管、头皮针、砂轮、 遵医嘱所需药物、启瓶器、输液胶贴)、手消毒 剂、治疗卡、配电盘、注射泵
微量注射泵操作技术
Logo
一、概述
什么是微量注射泵?
微量注射泵(简称微量泵)是一种新型泵力
仪器,能根据医嘱要求将少量药液均匀、持续、 定量注入人体静脉的注射装置。
微量注射泵 的特点
Company Logo
微量注射泵的适应症与禁忌症
【适应症】
Company Logo
二、评估患者
询问、了解患者的身体状况 向患者解释微量注射泵的方法、目的并取得 其配合 评估患者的皮肤、血管或输液情况。 进行必要的环境评估,要求环境清洁、安静
Company Logo
三、基本操作
2.药液准备
3.泵入治疗
四.整理用物
操作完毕协助其取舒适的体位,整理床单位分类整理用物,
洗手。
五.记录疗效
观察记录操作时间,必要时记录治疗效果及反应。
Company Logo
注射泵的使用注意事项 熟练掌握专业知识及药物作用和不良反应,认真执行医嘱, 对特殊药准确换算 严格执行交接班制度,微量泵上要注明药物名称、剂量、 配置时间、泵入速度,并签名。严防差错事故的发生。 加强巡视,注意观察输液管道是否通畅,药液有无渗漏、 脱管,一旦微量泵发生报警,及时查找原因,并做出相应 处理 妥善处理管道回血,严禁按快进键处理回血,可用另外一 副注射器将液体回抽再用生理盐水冲注,并将延长管内有 血的液体排除,调节微量泵后连接
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
ANUSPLIN使用说明
ANUSPLIN是提供实用的转换分析和对多变量数据采用薄盘光滑样条插值进行插值的工具。
它提供了完整的统计分析、数据诊断以及空间分布标准误。
同样也支持多种数据输入和表面查询功能。
薄盘光滑样条表面拟合法最早由Wahba出(1979),然后由Bates和Wahba(1982),Elden(1984),Hutchinson(1984)和deHoog(1985)对其进行了改进以适用于大数据集。
Batesetal.(1987)将其扩展为局部样条法,这样就可以把参数线性亚模型(或协变量)添加插值中,而不像以前只能考虑独立样条变量(即自变量)。
这为这些因变量提供由这些自因变量决定的参数form提供了一种极好的方式。
在没有独立样条变量的情况下(当前不允许),将进行简单的多变量线性回归。
薄盘光滑样条插值事实上可以被看作广义的标准多变量线性回归,但是参数模型由一个适用的光滑非参数函数所替代。
拟合函数的光滑度,或者与之相对的复杂度通常会根据数据拟合表面的最小预测误差通过GCV(广义交叉验证)自动计算。
GCV数据模拟结果的验证由Craven和Wahba(1979)年提出并完成。
Wahba(1990)对薄盘光滑样条技术各种模块进行了全面介绍。
Hutchinson(1991a)对月平均气象要素空间插值的基本理论和应用进行了简要的概述,Hutchinson(1993)和HutchinsonGessler(1994)对运算和相关行了对比。
Hutchinson (1995,1998ab)对该方法运用到了年和日降水数据的插值上。
同时模拟多个表面非常方便,尤其是对气象数据而言。
ANUSPLIN在允许任意多的这样的表面和“表面独立变量”,以便独立变量在各表面间做系统地改变。
ANUSPLIN允许系统查询这些表面及其标准误,点文件或者grid文件都行。
ANUSPLIN同样允许对独立变量和依从变量进行转换。
华中农业大学国家211工程大学华中农业大学国家211工程大学
下边将对ANUSPLIN个组件进行简要概述。
SPLINA:适用于<2000个要素的点文件。
允许一个或多个独立变量的任意数量的(局部)薄盘光滑样条函数。
光滑系数通常由GCV 决定
SPLINB:与SPLINA大致相同,但是它允许<10000个要素的点文件,可以用selnot/delnot模块先从大数据集中设置<2000个knots,同时还可用addnot对knots进行编辑。
AVGCVA:根据一系列不同的光滑系数,计算出由SPLINA生成的各表面与光滑系数对应的GCV和平均GCV值,计算结果将写成一个文件为进一步的制图服务
AVGCVB:为SPLINB服务,功能与AVGCVA类似。
LAPPNT:进行局部薄盘光滑样条表面估值并计算贝叶斯标准误,并生成一个点文件。
LAPGRD:功能与LAPPNT类似,只是最后结果将是一个规则的矩形栅格文件。
这个程序最好通过一个command-lineshell(即cmd文件)提取.。
在Unix系统,使用终端仿真窗口显示一个shellprompt。
在微软的Windows系统中,启动一个MS-DOSshell,如输入:
Splina<job.cmd>job.log
其中,job.cmd是一个输入的命令文件,而job.log则是程序执行后将输出的日志文件。
程序需录入项:(programinputs)
包括独立样条变量和协变量的个数,每个独立变量的上下限,每个变量的可选的转换试方式以及最低样条次数(决定不同的函数式),要模拟的表面数,以及各表面用以计算光滑系数的方法。
输入输出文件的指定,在SPLINB中还包括knots索引文件名。
位于独立变量界限外的点数据将予以排除。
这个界限有利于在不用切割点文件的情况下指定模拟的表面的范围。
界限值(相当于mask)允许留出一定的边距便于各表面间有重叠部分,对于极大的数据集来说可能需要这样做。
用户指定的界限将会对指定的数据格式和独立变量的样条次数进行了简单的检查。
如果选择的点数过少会出现错误提示。
通过与标准Fortran90的结合,ANUSPLIN4.1可以为更多的数据和数组动态分配内存。
同时,SPLINA和SPLINB都适用以任意点数来模拟任意数量的表面。
然而,最好还是不要让SPLINA的点数>2000,SPLINB的点数>10000.SPLIN适用于设置的knot于2000的情况。
SPLINA的主要存储空间是点文件所含的点数的平方,处理时间
则是点数量的立方。
SPLINB则与knot需要注意的是,SPLINA目前(4.1版式本)并不允许点文件中出现坐标重叠的点。
SPLINB中可以出现重坐标的点,但不允许有重坐标的knot。
计算函数略.大致为:Zi=f(xi)+bTyi+ei(i=1....N)
其中Zi为预估值,xi是一个d维的样条独立变量矩阵,f()是xi的未知光滑函数,yi是一个p维的协变量矩阵,b是yi的未知p维系数矩阵,ei是各独立变量,均值为0,.........(其中涉及到多个讨厌的参数,不想写了,)上式中T为b的上标
1)当P=0时,即没有协变量时,该函数式就是一个普通的薄盘样条模型,即简单的多变量线性回归.而如果f(xi)为0,即没有独立样条变量时,ANUSPLIN不可用
2):光滑参数P(不是P,应该是密度那个符号)是一个正数.它越趋近于0,则拟合函数越接近精确值,反之,若越趋向无穷,则拟合函数越接近最小二乘多项式(理解得有点怪),其阶数由d和xi的阶数决定.光滑参数通常根据GCV计算拟合表面的最小预测误差决定.(即可自动计算)
依从变量(因变量)转换
ANUSPLIN目前允许对自变量进行开平方或者求自然对数转换.在用SPLINSPLINB进行拟合前,可选用其中任意一种方式对变量进行转换.变量转换可以使其更符合正态分布,前提是变量的值是正数或非负数.该转换会自动传达给拟合表面的系数,因而LAPPNT和LAPGRD可以选择性的输出转换后的表面值或不经转换的表面值.不
经转换的表面估值可用依从变量的逆转换(求平方值或者指数)得到.Hutchinson(1998a)指出,在用薄盘光滑样条法进行拟合前,对依从变量日降水数据进行开平方转换,可减少近10%的插值误差.
如果选择输出未经转换的表面估值,LAPPNT和LAPGRD将同时计算其标准差.开平方转换公式的适用性由Hutchinson(1998a)进行了求证...(以下是一大堆公式,略去)
拟合气候表面
最早的拟合程序通常需要至少两个独立样条变量,(即f(xi)中i维矩阵),通常是经度、纬度,以度为单位。
但是在拟合温度或降水量时,可增加第三个独立变量,即海平面以上的高程(海拔)。
在把海拔作为第三个独立样条变量时,可以把它的单位转换为千米,即海拔值除以1000。
稍稍把海拔值缩放一下(此处指转换单位由米到千米)可略微改进拟合结果。
该改动最初由HutchinsonBischof(1983)提出,并由Hutchinson(1995,1998b)对此进行了论证.
在某些区域(restrictedareas),把海拔作为协变量而非独立样条变量时,拟合效果更佳。
在拟合一个温度表面时,作为协变量的海拔的系数将被作为一个先验的温度递减率(Hutchinson,1991a)看待。
其它影响气象变量的因素,如地形效应(topographiceffects)而非海拔,可以作为额外的协变量引入,如果可以求算出合适的参数并且相关数据可用的前提下.Hutchinsonetal.(1984ab,1996a)和
Hutchinson(1989am1991ab)对其它的气象插值软件进行了介绍.Hutchinsonetal.(1992,1996b)介绍了以样条法拟合气象表面应用于农业气象分类以及生物多样性评估的其它软件.
在拟合多变量气象表面时,只需要知道样点处的独立变量的值就可以了.因此,气象站点的坐标和海拔信息必须准确.坐标错误的点会在输出的最大残差日志里反映出来,即以降序排列的残差文件中,排在首位的几个极大的残差值对应的站点.最近又出了可检验引入由不同水平分辨率的DEM求算海拔,坡度和坡向进行插值的效用的软件(Hutchinson1995,1998b).
LAPGRD可用来估算气象要素和标准误,并生成一个规则的栅格图.providedregulargrideachindependentvariable,additionallati tude,issupplied.也就是说通常一个规则/标准的DEM栅格数据(是说DEM数据必须是一个规则的栅格?并且以什么投影呢?)是必须的.Hutchinson(1988,1989b,1996,1997)介绍了DEM的获取方法。