EN 55024- 2010 for ESD讲解
EN 55024- 2010 for surge讲解

闫春平
1
4.3 Surge limit / EN 55024
Signal port, and telecommunication ports
Copy from
EN 55024
Test specification
1 10/700 4 10/700
Units
波形校验/IEC61000-4-5
6
波形校验/IEC61000-4-5
波形校验/IEC61000-4-5
8
TEST SETUP/ IEC 61000-4-5
9
10
11
12
13
TEST SETUP/ IEC 61000-4-5
14
15
16
17
TEST SETUP/ IEC 61000-4-5
19
TEST SETUP/ IEC 61000-4-5
20
TEST SETUP/ Eቤተ መጻሕፍቲ ባይዱG0002341
EUT放置在离接地平板10cm上的非导电木板,运行EMI测试程式。参考接 地平板到EUT各边的投影要超过10cm。 所有I/O都要运行读/写功能。键盘,鼠标等严格意义上只是属于输入设 备,没有数据的传送。 EUT的功能在整个测试中要被监控到。 Workstation和server platforms当有多个供电系统时,可通过PDU同时连接 到发生器。 电源线长度为50cm. 所有超过3m的I/O线缆通过CLAMP执行测试,如网线,信号线,并联线, USB线,串联线,1394线。Clamp放置距离EUT 50cm.(所有的被测线缆 同时放在clamp中执行测试也是被允许的) 测试时连接CDN用于对AE的信号隔离。 在测试过程中要确保I/O线缆不能弯曲穿过容性耦合夹
利时集团HollySys Group矿用本质安全型PLC产品选型手册说明书

矿用本质安全型PLC产品选型手册和利时集团HollySys Group目 录矿用本质安全型控制系统四大关键Ex元件矿用本质安全型PLC系列MKC5109i 本安PLC28点CPU模块 MKC5211i 本安PLC16通道DI模块 MKC5221i 本安PLC12通道DO模块 MKC5311i 本安PLC4通道AI模块 MKC5331i 本安PLC4通道RTD模块 MKC5411i 本安PLC CAN通讯模块MKC5701i矿用本质安全型人机界面MKC5702i矿用本质安全型键盘MKC59XYi输出本质安全型电源和利时可靠性试验中心气候环境实验室EMC实验室机械环境实验室1 3 6 8 9 11 13 15 20 2428 29 30 31矿用本质安全型控制系统设备离不开四种关键部件:本质安全型稳压电源、本质安全型控制器、本质安全型人机界面、本质安全型键盘。
和利时凭借长年的技术积累和丰富的检测手段,成功开发了高性能的矿用输出本质安全型电源、矿用本质安全型PLC 、矿用本安人机界面和矿用本安键盘,均申请了防爆合格证书,可大大提高矿用本安型电气设备的开发速度。
矿用本质安全型控制系统四大关键Ex元件1 产品概述矿用本质安全型PLC 严格按照GB3836.1和GB3836.4标准设计,具有矿用本质安全特性且具有通用PLC 所有功能,在煤尘、瓦斯危险环境中可直接置于本安腔体内使用,适于在变化的控制场合进行现场组态,降低控制器体积和重量,便于移动和带电开盖维护。
该PLC 由CPU 模块和系列扩展模块组成,CPU 模块可以单独运行,也可以在CPU 模块IO 点数不满足系统需求时,连接扩展模块运行。
矿用本质安全型PLC 系列矿用本质安全型PLC 系列12 产品组成类 型型 号防爆证号名 称CPU模块MKC5109i 320150798X 本安PLC28点CPU模块本安PLC16通道DI模块本安PLC12通道DO模块本安PLC4通道AI模块本安PLC4通道RTD模块本安PLC CAN通讯模块320150799X 320150800X 320150797X 320150801X 320150837XMKC5211i MKC5221iMKC5311i MKC5331i MKC5411i扩展模块23 适用环境4 产品特点5 尺寸图海拔高度: ≤2000m ; 工作温度: -20~60℃ 存储温度: -40~70℃工作湿度: 5~95% 工作环境: 无滴水及震动 防爆类型: 本质安全型1)扩展能力:可以选择模拟量、数字量和通讯模块扩展;2)多机互联,通过RS 485实现多机互联,最多可实现16台CPU 之间的数据共享;3)支持以太网通讯下载,方便用户通过局域网对本安PLC 进行用户程序下载,远程数据 监控;4)可插拨端子,配置可插拨端子,在产品更换时,无需重新接线,避免了接线和拆线过程 中引入的故障,同时节省了更换模块的时间;5)简单可靠的安装;可实现导轨和螺钉两种安装方式;1)CPU模块2)扩展模块矿用本质安全型PLC 系列36安装方式7 技术指标MKC5109i 本安型PLC 28点CPU 模块456矿用本质安全型PLC 系列MKC5211i 本安型PLC 16通道数字量输入模块 7MKC5221i 本安型PLC 12通道DO模块MKC5311i 本安型PLC 4通道模拟量输入模块矿用本质安全型PLC 系列MKC5331i 本安型PLC 4通道RTD 模块接线方式重量(Max)防护等级500g现场侧可插拔端子,系统侧扁平线IP20矿用本质安全型PLC 系列MKC5411i 本安型PLC CAN 通讯模块MKC5701i矿用本质安全型人机界面1产品概述MKC5701i矿用本质安全型人机界面严格按照GB3836.1和GB3836.4标准设计,具有矿用本质安全特性且具有通用人机界面所有功能,在煤尘、瓦斯危险环境中可直接置于本安腔体内使用。
IT EMC测要求电脑工控机IT标准

LAN要用耦合夹
C
通信/信号端口 V
通信/信号端口针对没有 初级保护装置的
B 浪涌 (冲 击) 抗扰 度
AC差模(线-线):1KV 1,2/50(8/20) Tr/Hhus 交流电源输入 端口
V
温度: 湿度:
IEC61000-4-5 B
AC共模(线-地):+/-2KV 1,2/50(8/20) Tr/Hhus
A
30-230MHz 准峰值40dB(uV) 230-1000MHz 准峰值47dB(uV)
CISPR22 6.1 Table 6 1G以下 辐射 骚扰
B
30-230MHz 准峰值30dB(uV) 230-1000MHz 准峰值37dB(uV)
V 10M EUT最高内部频 率低于108MHZ, 则测量只进行 到1GHZ
V
C
差模(线-线):+/4KV 10/700 Tr/Hhus
通信/信号端口
通信/信号端口针对有初 级保护装置的
B RF传 导抗 扰度 EC61000-4-6 (注入 电 流)
DC共模(线-地):0.5KV 1,2/50(8/20) Tr/Hhus
直流电源输入 端口
A
0.15MHz-80Hz 3V/m 80%AM(1KHZ)
IT电脑类资讯类EMC测试要求
EN550022&EN55024 2010电磁兼容要求和试验要求: 产品名称: 名称 参考标准
CISPR22 5.1 Table 1
型号: 等 级
A
标准限值要求
0.15-0.50MHz 准峰值79dB(uV) 0.50-30MHz 准峰值73dB(uV) 0.15-0.50MHz 平均值66dB(uV) 0.50-30MHz 平均值60dB(uV) 0.15-0.50MHz 准峰值66-56dB(uV) 0.50-5MHz 准峰值56dB(uV) 5-30MHz 准峰值60dB(uV) 0.15-0.50MHz 平均值56-46dB(uV) 0.5-5MHz 平均值46dB(uV) 5-30MHz 平均值50dB(uV) 0.15-0.50MHz准峰值 97-87dB(uV)Voltage Limit 0.50-30MHz 准峰值 87dB(uV)Voltage Limit 0.15-0.50MHz平均值 84-74dB(uV)Voltage Limit 0.50-30MHz 平均值 74dB(uV) Voltage Limit 0.15-0.50MHz准峰值 84-74dB(uV)Voltage Limit 0.50-30MHz 准峰值 74dB(uV)Voltage Limit 0.15-0.50MHz平均值 74-64dB(uV)Voltage Limit 0.50-30MHz 平均值 64dB(uV) Voltage Limit
系統靜電放電(ESD)原理及測試標準介紹

系統靜電放電(ESD)原理及測試標準介紹一、靜電放電(ESD)原理介紹●ESD-----E lectro-S tatic D ischarge(1)摩擦生電: 兩種物質間交互作用產生,是一種材質表面原子因摩擦使外層電子游離化的一種現象,摩擦後兩物質一帶正電荷,另一帶負電荷。
(2)電磁感應:由強大電磁場所產生的效應,使兩物質間產生形同摩擦生電效應,使兩物質一帶正電荷,一帶負電荷的靜電現象。
●影響摩擦生電的因素相對溼度物質材料接觸面積摩擦頻率●生活中的靜電位準乾燥空氣(低溼度)-----5~35kV潮濕空氣(高溼度)-----0.1~1.5kV●人體靜電效應人體電容-----100-500pF人體所帶靜電≦35kVQ=CV 可計算人體靜電荷超過35kV人體會電暈放電●導體與非導體對地放電效果導體因原子結構的外層電子活動性強,接地可完全放電。
非導體因原子結構的外層電子活動性弱,接地無放電效果。
●靜電效應硬體破壞-----半導體介面焚毀、IC金屬連接焚毀、場效電晶體介電崩潰類比系統(如音響)短暫停止軟體破壞-----邏輯錯誤、系統重置、資料損失、程式損失二、測試標準介紹●IEC 61000-4-2IEC-----International Electrotechnical Commission廣泛被世界各國引用的ESD測試規格被歐聯引用之規格稱為EN 61000-4-2●ANSI C63.16ANSI-----American National Standards Institute廣泛被美國白色貨物(White Goods)、消費性產品(Consumer Products)及通訊產品(Telecom)製造商所引用的測試標準White Goods-----電冰箱、洗衣機、爐具等Consumer Products-----電視機、音響設備等三、IEC/EN 61000-4-2介紹●測試位準Level 測試電壓接觸放電(Contact Discharge) kV測試電壓空氣放電(Air Discharge) kV1 2 3 4 X2468Special24815Special●靜電產生器(ESD generator) 的規格與特性-儲能電容(energy storage capacitance)- 放電電阻(discharge resistance)- 充電電阻(charging resistance)- 輸出電壓(output voltage)- 輸出誤差(tolerance of the output indication) - 輸出極性(polarity of the output indication) - 靜電壓維持時間(holding time)- 放電方式(discharge, mode of operation) 150 pF ±10 %330 Ω±10 %50 MΩ至100 MΩ高於8 kV (contact discharge) 高於15 kV (air discharge)±5 %正極與負極(positive and negative) 最少 5 秒單一放電( 每次放電間隔最少1秒)●輸出波形特性Level IndicatedvoltagekV First peak current ofdischarge ±10 %ARise time tr withdischarge switchnsCurrent(±30 %)at 30 nsACurrent(±30 %)at 60 nsA1 2 3 424687.51522.5300.7 to 10.7 to 10.7 to 10.7 to 14812162468 如下圖:Fig. ESD產生器輸出電流的典型波形●測試環境溫度(ambient temperature) 相對濕度(relative humidity)大氣壓力(atmospheric pressure) 15 ℃to 35 ℃30 % to 60 %86 kPa ( 860 mbar ) to 106 kPa ( 1060 mbar )●EUT SETUPFig. 桌上型EUT 擺設方法Fig. 落地型擺設方法●測試方法 :1.將 EUT 及其週邊擺設定位 , 並查察 EUT 各項功能皆可正常運作 .2. 依下述方式對 EUT 執行靜電放電 (註1) , 並觀察測試過程中EUT 各項功能是否正常 .a. 直接放電對待測物(EUT)接觸放電 (Contact Discharge)將 "靜電槍頭" (註2) 直接接觸 EUT 外殼導電部份 ,再啟動充放電開關 .對待測物隔空放電 (Air Discharge)啟動充放電開關充電 , 在安全無虞之下(在不造成 EUT 受測點被損壞的狀況下) , 儘快將 "靜電槍頭" 以垂直角度接近並接觸 EUT 外殼。
ESD静电放电试验测试方法

16
测试场地注意要点
测试前必须确认Ground Plane接地螺丝未松脱, HCP/VCP接地阻抗470k Ω是否正确是否正确。 测试场地必须控制温湿度, 值为:Ambient Temperature :15 ℃ to 35 ℃℃ Relative Humidity :30% to 60% 以上条件以开启除湿机及冷气机调节并用温湿度计监控 测试桌上除待测对象外, 请勿摆放不相干对象以免影响测试场地之准确性, 每 天机器使用前必需进行Spot Check, 确认output 正常。 Ground Reference Plane必须置于地上, 且其大小必须大于EUT 或 coupling plane的四周至少50 cm 以上 EUT 和测试空间的墙壁及任何金属物必须至少保持1 米以上 HCP 大小为1.6 m x 0.8 m( VCP 大小为50 cm x 50 cm ), 且必须置于木 质桌上, EUT和HCP 间必须以一0.5 mm 的绝缘物质阻隔 静电枪Grounding metal strap 必须确实接地。(通常长度为2 米以内) 桌上型待测物必须置于一80 cm 高之木质桌上且此桌子必须于Ground Reference Plane 上
6. 对于Class II (没有Safety Ground) 待测物是否必须主动于每次 Discharge 后对机壳放电再执行另一次Discharge 请与客户讨论后决 定,,并记录说明并记录说明。 7. 依据相关产品测试标准作测试结果判定并填具ESD TEST RECORD 更多设计资料请访问金三维视频教程网: 19
更多设计资料请访问金三维视频教程网: 17
1. 测试Sample依其正常功能, 配合外围组成Test Configuration, 测试时尽可能Active每种功能, , 来确认测试中所有Function 正 常, , 电源线、信号线种类请依照客户规格使用。用。 2. 依产品结构选定测试点, 所有可能放电的位置都必须列为测试点 3. 依照客户提出之测试规格, 测试电压值由正、负极性, 由低而高依 序执行, 其中Contact Discharge 测试, (含Direct 及Indirect) 及Air Discharge 测试每一个测试点Discharge至少10 次, 每次至少间隔1 秒, (若依Product standard, 如YD 1215 有特别要求,,优先依照其规 定) 4. 依下述方式对EUT 执行静电放电, 并观察测试过程中EUT各项功 能是否正常..
en55024标准名称

en55024标准名称
EN 55024是欧洲电子设备用电磁兼容性标准的一个重要名称。
它规定了电子设备在电磁环境中的性能要求,以确保设备在遇到电磁干扰时能正常工作,同时不会对其它设备产生干扰。
EN 55024标准适用于各种类型的电子设备,包括计算机、通信设备、家用电器、工业设备等。
根据这一标准,电子设备应具备抵抗电磁场干扰、抵抗电静电放电、抵抗快速瞬变干扰等能力。
根据EN 55024标准的要求,电子设备应该通过各种测试,以验证其在特定的电磁环境中的表现。
这些测试包括:
1. 抗传导干扰测试:验证设备是否能够抵抗来自电源线和信号线的传导干扰;
2. 抗辐射干扰测试:验证设备是否能够抵抗来自电磁场中的辐射干扰;
3. 静电放电测试:验证设备是否能够抵抗来自静电放电的干扰;
4. 快速瞬变测试:验证设备是否能够抵抗来自突然的电压和电流变化引起的干扰。
通过遵循EN 55024标准,设备制造商可以确保其产品在电磁环境中能够正常运行,并且不会对其他设备造成干扰。
这对于确保电子设备的可靠性和互通性至关重要。
总结起来,EN 55024标准为电子设备的电磁兼容性提供了统一的要求和测试方法,以确保设备在电磁环境中的稳定性和可靠性。
制造商和用户都应该密切遵守这一标准,以确保设备在使用过程中不会受到电磁干扰的影响。
EN 55024- 2010 for EFT讲解

TEST SETUP/ ENG0002341
EUT放置在离接地平板10cm上的非导电木板,运行EMI测试程式。参考接 地平板到EUT各边的投影要超过10cm。 所有I/O都要运行读/写功能。键盘,鼠标等严格意义上只是属于输入设 备,没有数据的传送。 EUT的功能在整个测试中要被监控到。 Workstation和server platforms当有多个供电系统时,可通过PDU同时连接 到发生器。 电源线长度为50cm. 所有超过3m的I/O线缆通过CLAMP执行测试,如网线,信号线,并联线, USB线,串联线,1394线。Clamp放置距离EUT 50cm.(所有的被测线缆 同时放在clamp中执行测试也是被允许的) 测试时连接CDN用于对AE的信号隔离。
2
Level
500V
Acceptance Criteria
B
4
TEST SETUP/ IEC 61000-4-4
7 test setup 基于试验环境,定义不同类型的试验: -- 在实验室进行的型式试验 -- 在设备最终安装条件下,对设备进行的安装后试验 优先采用在实验室进行的型式试验。 应按照制造厂的安装说明书设置EUT。 7.1 测试设备 测试设置包含以下方面: -- 参考接地平板 -- 耦合设备 -- 去耦网络 -- 测量发射器
参考接地平板耦合设备去耦网络测量发射器5testsetupiec610004472实验室进行的型式测试的试验配置721测试条件测试的环境参考条件如81固定落地式设备或者桌上型设备和设计安装于其他配置中的设备都应放置在接地参考平面上用厚度为01m001m的绝缘支座隔开
EN 55024- 2010 for EFT讲解
在安装后试验中,经过制造商与用户的同意,对于外部电缆,可以将使 用电缆同时放入耦合夹之内来进行测试。
EN55022 EN55024 EN55014 CE-EMC测试

电磁兼容(EMC )是对电子产品在电磁场方面干扰大小(EMI)和抗干扰能力(EMS )的综合评定,是产品质量最重要的指标之一,电磁兼容的测量由测试场地和测试仪器组成。
EMC 包含两大项:EMI (干扰)和 EMS(敏感度,抗干扰)EMI 测试项包括:RE (辐射,发射) CE(传导干扰) Harmonic (谐波) Flicker (闪烁)EMS 测试项包括:ESD (静电) EFT (瞬态脉冲干扰) DIP(电压跌落) CS (传导抗干扰)RS (辐射抗干扰)Surge (浪涌,雷击) PMS(工频磁场抗扰度)一、EMI (电磁骚扰)分射频和工频两类测试l 射频类测试项目:1.1 射频分传导和辐射两项测试 射频传导(屏蔽室测试)1.1.1 传导分电压和功率两项测试 1.1.2 传导电压标准:CISPR11、14、15、221.1.3 传导功率标准:CISPR11、14 射频辐射(电波暗室测试)1.1.4 射频辐射标准:CISPR11、22、IEC60571l 工频类测试项目(实验室测试) 1.2 工频分谐波和闪烁两项测试工频谐波1.2.1 IEC6100-3-2 工频闪烁1.2.2 IEC6100-3-3二、EMS (电磁敏感度)分瞬变、射频、低频磁场、电源质量l 瞬变类测试项目(实验室测试) 2.1 瞬变分静电、瞬变脉冲和浪涌三项测试瞬变静电IEC6100-4-2 瞬变脉冲IEC6100-4-4 瞬变浪涌IEC6100-4-5 l 射频类项目2.2 射频分传导和辐射两项测试射频传导IEC61004-6(实验室测试) 射频辐射IEC6100-4-3(电波暗室测试) l 低频磁场类测试项目(实验室测试) 2.3 低频磁场分脉冲磁场和工频磁场两项测试脉冲磁场IEC6100-4-9 工频磁场IEC6100-4-8电源质量类测试项目(实验室测试) 2.4分跌落、中断、电压变化三项测试 IEC6100-4-11注:1. 传导功率测试面积 > 7x1M 2. 传导电压测试桌:推荐 2x1.5x0.8 要考虑柜式设备的测试面积。
EN--55024--2010-for-surge讲解

Performance Criterion
C
Remark
4 10/700
kV (Peak) Tr/Th μs
2
Surge limit / EN 5பைடு நூலகம்024
Input ac power port(including equipment marketed with a separate ac/dc power converter)
Copy from EN 55024
Test
Units
specification
1(line to line) kV (Peak) 2(line to earth) kV (Peak) 1.2/50(8/20) Tr/Th μs
Performance Criterion
B
Remark
3
Surge limit / EN 55024
EN 55024- 2010 for surge讲解
闫春平
1
4.3 Surge limit / EN 55024
Signal port, and telecommunication ports
Copy from EN 55024
Test
Units
specification
1 10/700
kV (Peak) Tr/Th μs
18
TEST SETUP/ IEC 61000-4-5
8 试验程序 8.1 实验室参考条件 8.1.1 气候条件
除非通用标准,产品类标准和产品标准另有规定,实验室的气候条件应该在EUT和试验 仪器各自的制造商规定的设备正常工作的范围内 相对湿度过高会引起EUT表面凝露则不能执行测试。 8.1.2 电磁环境 实验室的电磁环境应被监控避免对EUT的正常操作产生影响。
华为AR550系列物联网门路器数据手册说明书

HUAWEI AR550 Series IoTGateway DatasheetJan, 2017Copyright © Huawei Technologies Co., Ltd. 2018. All rights reserved.Trademark NoticeGeneral Disclaimer, HUAWEI, and are trademarks or registered trademarks of Huawei Technologies Co., Ltd.Other trademarks, product, service and company names mentioned are the property of their respective owners.The information in this document may contain predictive statementsincluding, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictivestatements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.HUAWEI TECHNOLOGIES CO.,LTD.Huawei Industrial BaseBantian LonggangShenzhen 518129,P.R.ChinaTel: +86 755 28780808Product OverviewAR550 series industrial IoT gateway are specially designed for network communication in challenging environments such as extreme temperature, high humidity, and electromagnetic interference. The AR550 series integrates routing, switching, IPSec VPN, and other functions, provides powerful application scalability, and widely applies to various industrial automation fields, such as electric power automation and transportation automation.The AR550 series is available in four models: AR550C-4GE, AR550C-2C6GE, AR550-8FE-D-H and AR550-24FE-D-H.AR550-24FE-D-HAR550-8FE-D-HKey Features and ValuesIndustrial Design, Premium Quality• Adopts a fan-free design and works in a wide temperature range of –40o C to +70o C.• Works properly in environments with strong electromagnetic interference and complies with IEEE1613 standards.• Complies with environment standards of substations: IEC61850-3/IEEE1613.• Supports a Mean Time Between Failures (MTBF) of more than 50 years. • Supports dual-input DC power supply, DO (Digit Output) alarm relays.Flexible Networking, Secure and Reliable Services• Provides 28 interfaces to connect a variety of terminals.• Provides RS485 to connect multiple serial terminals• Supports various networking modes, such as closed ring, open ring, multi-ring, and dual-ring.• Supports Smart Ethernet Protection (SEP), which can implement fast protection switching.• Uses multiple technologies to guarantee data security, such as IPSec VPN data encryption, 802.1x, and port locking.Easy Deployment, Convenient O&M• Web-based visualized configuration and user-friendly UI• Remote topology management and batch configuration or upgrade • USB-based deployment and plug-and-play• One-click configuration backup and simplified device replacement • High-Density industrial Power over Ethernet(POE) simplify field wiring• Fixed interfaces: 4 x GE combo, 8 x FE RJ45, 1 x USB2.0, and 1 x digital output (DO)• Working temperature: –40o C to +70o C• Dimensions (W x D x H): 97 mm x 133 mm x 150 mm • Redundant power supplies: 9.6 V to 60 V DC• Fixed interfaces: 2 x 2.5G SFP(compatible with GE), 2 x GE combo, 6 x GE RJ45, 1 x RS485, 1 x USB2.0, 1 x DI, 1 x DO • Working temperature: –40o C to +70o C• Dimensions (W x D x H): 44 mm x 133 mm x 150 mm • Redundant power supplies: 9.6V to 60V DC• Fixed interfaces: 2 x 2.5G SFP(compatible with GE), 4 x GE RJ45, 1 x USB2.0, 1 x DI, 1 x DO • Working temperature: –40o C to +70o C• Dimensions (W x D x H): 44 mm x 133 mm x 150 mm • Redundant power supplies: 9.6V to 60V DC• Fixed interfaces: 4 x GE combo, 24 x FE RJ45, 1 x USB2.0, and 1 x DO • Working temperature: –40o C to +70o C• Dimensions (W x D x H): 133 mm x 133 mm x 150 mm • Redundant power supplies: 9.6 V to 60 V DCAR550C-2C6GEAR550C-4GEA R 550 S e r i e s I n d u s t r i a l I o T G a t e w a yA R 550 S e r i e s I n d u s t r i a l I o T G a t e w a y34Typical ApplicationElectric PowerThe AR550 supports the SEP protocol to ensure highly reliable network communication by implementing fast protection switching. With 28 Ethernet interfaces, the AR550 provides access to a large number of densely deployed electric terminals. It complies with IEEE1613 and IEC61850-3 substation environment standards and can be used in power distribution automation and automatic substation access scenarios, boosting digital and smart development of the electric power industry.TransportationTraffic control and surveillance centerAR550AR550SEPIn addition to offering reliable, instant, and secure communication, the AR550 meets anti-vibration requirements defined by EN50155 standards of the transportation industry. The AR550 therefore can be used to construct the smart transportation system for traffic and vehicle control, such as express way monitoring, vehicle-mounted Passenger Information System (PIS), and vehicle-ground communication. After the AR550 is installed, services can be deployed using the USB drive, which is suitable for scenarios where there are many sparsely distributed stations.Master stationMSTP/IPSubstationPower stationPower stationAR550AR550RTURTURTURTUSubstationSubstationVideo BackhaulIP cameraIP camera EthernetAnalog camera DVRVideo surveillance centerAR550Video surveillance is popular in various industries. Different access conditions pose higher requirements on the installationspace and mode, operating temperature and humidity of video backhaul devices. The AR550 uses a compact design and has a small size. It can be installed on guide rails and supports a wide operating temperature, meeting outdoor video backhauling requirements in harsh environments.Ethernet Access in Other Industries or Harsh EnvironmentsThe industrial Ethernet is one major component of the industrial control field. Huawei AR550 adopts an industrial design and integrates abundant features, such as routing and IPSec VPN. It can be widely used for industrial Ethernet access in harsh environments, such as high temperature, low temperature, and strong electromagnetic interference. Additional, it provides end-to-end security guarantee for production data transmission.Product SpecificationsThe following table describes major specifications of the AR550.This content is applicable only to regions outside mainland China. Huawei reserves the right to interpret this content.Specification Power AdapterPower parametersPower input (high-voltage AC/DC)• 88 V to 300 V DC (terminal block)• 90 V to 264 V AC (terminal block)Power output:• 12 V DC (terminal block)Weight0.9 kgDimensions (W x D x H)40 x133 x 150 mmStorage temperature–40o C to +85o CInstallation mode Installation on a DIN railOperating temperature–40o C to +70o COperating humidity5% to 95% (non-condensing)Specification PoE Power AdapterPower parametersOne Power input• 77 V to 300 V DC (terminal block)• 90 V to 290 V AC (terminal block)Four Power outputs:• 56 V DC (terminal block)Weight 1.47KgDimensions (W x D x H)65 x133 x 150 mmStorage temperature–40o C to +85o CInstallation mode Installation on a DIN railOperating temperature–40o C to +70o COperating humidity5% to 95% (non-condensing) Power Supply ModulesAC power adapter240W PoE Power SupplyThe PAC-60WB is used as AC power adapter for AR550.The PAC240S53-CN is used as AC PoE power adapter for AR550C-2C6GE.IEC61000-4-8 (Power Frequency Magnetic Field Immunity) :30A/m (Long time) , 300A/m( short time)IEC61000-4-11 (AC DIP)IEC61000-4-10 (Damped Oscillatory Magnetic Field Immunity) :30A/mIEC61000-4-18 (Damped Oscillatory Wave) :2.5kV(CM)/1kV(DM)IEC6100-4-16 (Immunity to conducted, common mode) Safety UL60950-1, IEC60950-1, CEShock and Vibration test IEC60870-2-2 Cm IEC61373 Class BCertification/Standards compliance CEUSA FCC(47CFR Part 15) China CCC, GB 9254 CB ( IEC 60950) NRTL (UL60950-1)SNMP Support No ConfigurationBefore selecting the AR550, determine the device model, software configuration, and accessories.Device modelSelect the device model according to the interface type and service requirements.SoftwareAR550 software is classified into basic software and the advanced routing value-added service package. The basic software contains basic features, including Layer 2 switching, device management, and static routes. The value-added service package contains Layer 3 dynamic routing, VPN, and other advanced features.AccessoriesConfigure the types and quantity of the industrial 60 W power adapters, optical modules, and cables according to site environments.For more information, visit /en or contact your local Huawei sales office.Ordering InformationOrdering InformationDevice modelAR550C-4GE (2 x 2.5G SFP(Compatible with GE), 4 x GE, 1 x USB2.0, 1 x DI and 1 x DO)AR550C-2C6GE (2 x 2.5G SFP(Compatible with GE), 2 x GE combo(POE+), 2 x GE RJ45(POE++), 4 x GE(POE+), 1 x USB2.0, 1 x RS485, 1 x DI and 1 x DO)AR550-8FE-D-H (8 x 100M RJ45, 4 x GE combo, 1 x DO, DC power supply)AR550-24FE-D-H (24 x 100M RJ45, 4 x GE combo, 1 x DO, DC power supply)Accessories-power supply, cables and CabinetIndustrial 60 W power supply, 12 V AC/DC to DC, DIN rail, 88 V to 300 V DC, and 90 V to 264 V AC Industrial 240 W PoE power supply, 56 V AC/DC to DC, DIN rail, 77 V to 300 V DC, and 90 V to 290 V ACPOE midspan, 8 x GE MIDSPAN PORT,8 x GE input ,1 x FE mgmt ,1 x CONSOLE,1 x AC 100-240V INPUT,1 x DC12V 2.1A OUTPUTPower Distribution Cabinet,F01A109,220V,1PH,50Hz,2AAccessories-storage deviceUSB flash drive (USB Flash Disk,72mmX21.9mmX13mm,16GB,USB2.0,Alcor Micro MCU)Accessories-industrial optical moduleeSFP optical module (FE, single-mode, 1310 nm, 15 km, LC)eSFP optical module (GE, single-mode, 1310 nm, 10 km, LC)eSFP optical module (GE, single-mode, 1310 nm, 40 km, LC)eSFP optical module (GE, multimode, 850 nm, 0.55 km, LC)A R 550 S e r i e s I n d u s t r i a l I o T G a t e w a y9。
静电放电抗扰度试验

测试步骤
1. 测试Sample依其正常功能, 配合外围组成Test Configuration, 测试时尽可能Active每种功能, , 来确认测试中所有Function 正 常, , 电源线、信号线种类请依照客户规格使用。用。 2. 依产品结构选定测试点, 所有可能放电的位置都必须列为测试点 3. 依照客户提出之测试规格, 测试电压值由正、负极性, 由低而高依 序执行, 其中Contact Discharge 测试, (含Direct 及Indirect) 及Air Discharge 测试每一个测试点Discharge至少10 次, 每次至少间隔1 秒, (若依Product standard, 如YD 1215 有特别要求,,优先依照其规 定) 4. 依下述方式对EUT 执行静电放电, 并观察测试过程中EUT各项功 能是否正常..
直接放电对待测物eut接触放电contactdischarge针对eut上所有导电表面directdischarge及hcpvcpindirectdischarge作测试静电枪头dischargetip请使用尖头直接接触eut外壳导电部份于电压指示到达要求值时将放电针垂直接触测试点后按控制按钮放电等待电压指示再次达到要求值时再次按钮放电如此反复执行直到测试完成19对待测物隔空放电airdischarge针对放电鎗无法直接接触contact放电的表面或缝隙则执行airdischarge静电枪头dischargetip请使用圆头直接接触eut外壳导电部份启动充放电开关充电在安全无虞之下在不造成eut受测点被损坏的状况下尽快将静电枪头以垂直角度接近并接触eut外壳
b. 间接放电 对耦合平面板(coupling plane) 接触放电接触放电
耦合平面板有垂直(VCP) , 水平(HCP) 之分, 以接触放电方式对VCP, HCP 放电放电:
EMI经典资料

EN55022測試法規非故意輻射、故意輻射非故意輻射(Unintentional):產品產生不想要的電磁波輻射,造成干擾¾ITE (Information Technology Equipment):電腦,LCD Monitor ,DVD 、電視、投影機、¾DOC (Declaration of Conformity):自我認證方式¾証實驗室測試的報告不用被審核,但在外銷國該地會被抽驗故意輻射(Intentional):使用無線電波來通信¾RF 產品:WLAN、手機¾管制比較嚴格¾歐規: 採行DOC方式¾FCC : 採行FCC ID 方式¾認証實驗室測試的報告必須通過TCB 審核,取得FCC ID後才可販售 FCC 只測試EMI :¾RE (輻射干擾):Radiation Emission (30MHz ~ 1GHz)量測頻率範圍(30MHz ~ 1GHz)¾CE (電源線干擾) : Conducted Emission量測頻率範圍(150KHz ~ 30MHz)EMI測試:EN 55022EMI 測試:測試待測物(EUT)產生輻射干擾的強度量測EUT產生的輻射干擾(Radiated Emission) :RE¾測試方法:依據EN 55022¾10米量測(Open Area Site)¾量測EUT產生的電磁波輻射(30MHz ~1GHz)量測EUT產生的傳導輻射干擾(Conducted Emission) :CE¾測試方法:依據EN 55022¾量測電磁波雜訊出現在EUT的DC 和AC電源端(150K ~30MHz)¾量測Telecommunication ports 端出現輻射干擾值(150K ~30MHz):量測EUT產生的諧波電流干擾值:Power Harmonic¾測試方法:依據EN 61000-3-2¾量測EUT在交流電源端的諧波電流,避免對電力公司造成影響量測EUT的輸出電壓變動和閃爍(Voltage fluctuation and flicker) :Flicker ¾測試方法:依據EN 61000-3-3¾量測EUT的AC電源端的電壓變動和閃爍值10 米電波暗室10m chamber 價格大約NT 4,000萬場地符合標準?Absorber 不可能對30MHz ~ 1GHz 的電磁波全部吸收缺點:反射比OATS 強優點:可以避免空中廣播FM (88MHz~108MHz) ,手機(900MHz)干擾量測天線:Bi-Log侍測物(EUT)歐規採用10 米量測FCC 採用3米或10 米量測都可以150KHz to 30MHz Open Area Test Site (10 m)侍測物傳導干擾量測OATS (Open Area Test Site)FRP Doom量測天線:Bi-Log OATS 價格便宜優點:反射比10m chamber 小缺點:受空中廣播FM (88MHz~108MHz) ,手機(900MHz)干擾必須在深山,遠離市區Measuring Distance 轉換New limit (dBuV/m)=published limit(dBuV/m)+20log[d/new distance (m)] d=the distance identified within the test standard.例如10m轉換3m limit37 + 20log(10m/3m)37+20*0.52=~47CISPR 22 A1:2005-07 版本中RE (Radiated Emission) 的量測已要求1GHz以上,最高到6GHz,而且1GHz以上是採用3米量測。
FOXCONN P67A 系列主板 说明书

Signature :
Date :
ห้องสมุดไป่ตู้2010
安装注意事项:
NING AR ! W
■
■
静电释放(ESD)是不同物体间正负电荷的快速中和,会产生瞬间的电流。通常静电释放 会伴随火花出现,并可在瞬间对电子设备器件造成严重损坏,所以当触碰电子元件时请 戴好静电防护手环。 请确保在安装或卸除CPU、内存、扩展卡以及其他外围设备前已将电源断开。建议切断 交流电源,以避免硬件损坏。
UT IO N
W A
R NI N G!
!
CA
注意:表示可能会损坏硬件或导致数据丢失,并告诉您如何避免此类问题。
警告:表示存在导致财产损失,人身伤害等潜在危险。
更多信息:
如果您想了解更多的产品信息,请访问如下网站: 电子信息产品污染控制标示:图中之数字为产品之环保使用期限。仅指电子信息产品中 含有的有毒有害物质或元素不致发生外泄或突变从而对环境造成污染或对人身、财产 造成严重损害的期限。 有毒有害物质或元素的名称及含量说明标示: 有害物质或元素 部件名称 印刷电路板及其电子元件 外部信号连接头及线材 铅(Pb) × × 镉(Cd) ○ ○ 汞(Hg) ○ ○ 六价铬 (Cr6+) ○ ○ 多溴联苯 (PBB) ○ ○ 多溴二苯醚 (PBDE) ○ ○
○: 表示该有毒有害物质在该部件所有均质材料中的含量均在《电子信息产品中有毒有害物质的限 量要求标准》规定的限量要求以下。 ×: 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出《电子信息产品中有毒有害物 质的限量要求标准》规定的限量要求,不过其含量超出是因为目前业界还没有成熟的可替代的 技术。 备注:此产品所标示之环保使用期限,系指在一般正常使用状况下。
EMC电磁兼容指令(2014-30-EU)要求、标准、规定、规范与评定程序

EMC电磁兼容指令(2014-30-EU)要求、标准、规定、规范与评定程序一、电磁兼容EMC指令概述:1、EMC指令是欧洲联盟制定的一项法规,全称为电磁兼容性(Electromagnetic Compatibility)指令,编号为2014/30/EU。
该指令的目的是确保在欧洲市场上销售的电气和电子设备能够满足特定的电磁兼容性要求,从而减少设备之间的电磁干扰。
2、EMC指令适用于在欧洲市场上销售的电气和电子设备,当产品带电存在电磁干扰或抗干扰要求时,需要进行EMC认证并遵守EMC指令。
3、电磁兼容性(EMC)2014/30/EU指令对电气和电子设备的市场准入起到了关键作用。
通过确保设备的电磁兼容性,该指令维护了设备之间的相互作用和性能稳定。
企业和相关行业须遵守该指令,以确保设备符合要求并获得欧盟市场准入。
二、EMC指令2014/30/EU的定义和目的:1、EMC指令2014/30/EU于2016年4月20日生效,并与新立法框架保持一致。
该指令确保投放到欧盟市场的所有电气和电子设备均符合所允许的足够水平的电磁兼容性。
在这方面,电气产品不应产生任何电磁干扰或受到电磁干扰的影响。
EMC的目的是控制电气设备互连或彼此靠近时出现的所有副作用。
例如,电视机,收音机,电源线和其他设备之间可能存在干扰。
此外,该指令限制了电气设备的电磁辐射,以使此类设备在按预期使用时不会干扰其他设备的活动,例如无线电或电信。
2、EMC指令主要目标:在欧盟市场投放的所有电气和电子设备(无论是固定装置还是固定装置),在正确安装,维护和使用以达到其预期目的时,都必须符合该指令的要求;所有固定安装都必须具有良好工程实践的特征。
三、EMC指令2014/30/EU的范围:1、新的EMC指令2014/30/EU具有与2004/108/EC的旧EMC指令相同的范围,涵盖了广泛的设备,包括电气和电子设备,系统和装置(定义为设备或固定装置)。
在这方面,重要的是要指定设备和固定装置的含义。
最新EN55022EN55024EN55014CE-EMC测试汇总

E N55022E N55024E N5 5014C E-E M C测试仅供学习与交流,如有侵权请联系网站删除 谢谢2EMC 测试-概述电磁兼容(EMC )是对电子产品在电磁场方面干扰大小(EMI )和抗干扰能力(EMS )的综合评定,是产品质量最重要的指标之一,电磁兼容的测量由测试场地和测试仪器组成。
EMC 包含两大项:EMI (干扰)和 EMS(敏感度,抗干扰)EMI 测试项包括:RE (辐射,发射)CE(传导干扰) Harmonic (谐波) Flicker (闪烁)EMS 测试项包括:ESD (静电) EFT (瞬态脉冲干扰) DIP(电压跌落) CS (传导抗干扰) RS (辐射抗干扰) Surge (浪涌,雷击) PMS(工频磁场抗扰度)一、EMI (电磁骚扰)分射频和工频两类测试l 射频类测试项目:1.1 射频分传导和辐射两项测试 射频传导(屏蔽室测试)1.1.1 传导分电压和功率两项测试 1.1.2 传导电压标准:CISPR11、14、15、221.1.3 传导功率标准:CISPR11、14 射频辐射(电波暗室测试) 1.1.4 射频辐射标准:CISPR11、22、IEC60571l 工频类测试项目(实验室测试) 1.2 工频分谐波和闪烁两项测试 工频谐波1.2.1 IEC6100-3-2 工频闪烁1.2.2 IEC6100-3-3 二、EMS (电磁敏感度)分瞬变、射频、低频磁场、电源质量l 瞬变类测试项目(实验室测试) 2.1 瞬变分静电、瞬变脉冲和浪涌三项测试瞬变静电IEC6100-4-2 瞬变脉冲IEC6100-4-4仅供学习与交流,如有侵权请联系网站删除 谢谢3瞬变浪涌IEC6100-4-5 l 射频类项目2.2 射频分传导和辐射两项测试 射频传导IEC61004-6(实验室测试) 射频辐射IEC6100-4-3(电波暗室测试) l 低频磁场类测试项目(实验室测试) 2.3 低频磁场分脉冲磁场和工频磁场两项测试脉冲磁场IEC6100-4-9 工频磁场IEC6100-4-8电源质量类测试项目(实验室测试) 2.4分跌落、中断、电压变化三项测试 IEC6100-4-11注:1. 传导功率测试面积 > 7x1M2. 传导电压测试桌:推荐 2x1.5x0.8 要考虑柜式设备的测试面积。
ESD知识

– Performance Criteria B
– Performance Criteria C
ESD判定標準定義
– Performance Criteria A
•產品於測試前後及測試中之功能不可有任何改變者。 •製造者可以於說明書中指明暴露於測試條件下允許少許受干擾, 但不影響設備正常功能者, 但測試後須自動恢復正常。 •上述中的條件測試, 測試實驗室須依製造者所述之 Permission level 執行測試, 以驗證其真實性, 並記錄於 Report 中。 •測試中可以有預期功能上的降損, 但測試後, 無須人工介入且 功能正常運作。 •上述中的錯誤, 若製造者於說明書中未提及可允許的情況, 則 須依使用者立場來對此產品來加以判定, 如: 儲存設備, 於干 擾環境存在時, 根本無法儲存或儲存的 Data 和預期完全不同, 雖干擾環境消失功能正常, 應不可列為此級水準。 •可以有功能的錯誤, 且此錯誤可以由 EUT 自動恢復或藉由人 工方式依使用手冊恢復之。 •存於不易變記憶體中的資料或因有電池保護的資料或功能, 不 可有遺失。
直接放電(Contact discharge) 至少放電 200 次 (正、負各 100 次; 至少 4 個點, 每個點各 50 次) 上述 4 個點的定義:其中一個點打 EUT 正面之水平耦合板(HCP)中心點位置至少 50 次 (正、負至少 25 次), 其餘三面至少 各直接打 50次於 EUT 上。 若無直接放電點存在, 則施與垂直耦合板 (VCP)之間接放電(indirect)至少 200 次。 有外漆之 EUT, 應判斷其噴漆的目的為美 觀非絕緣目的時, 應將漆刺破施與放電。
B
空間放電(air discharge) 無法直接放電的地方, 應施與空 間放電(air discharge), 如: keyboard按鍵間之間隙, keyboard 之蓋子及電話筒之類。 有外漆之 EUT, 若會放電亦應施 與放電。(不論外漆之目的為何) 每一放電點至少放電正、負 10 次。 每次放電間隔至少 1 秒鐘。Leabharlann • • • • • • •
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
IEC 61000-4-2 8.3.1和A.5。
8.3.3 间接放电 8.3.3.1 靠近EUT的放电 当对耦合板进行的放电,选用接触放电模式。 8.3.3.2 HCP 对水平耦合板放电应在水平方向对其边缘施加。 对水平耦合板放电数量至少10次,放电位置在HCP前边缘中心,距离EUT 0.1m的位置。放电时,放电电极的长轴处在水平耦合板的平面,并与其 前面的边缘垂直。 放电前,发生器的电极先接触后放电。 产品标准要求EUT的所有边都应被测试。 8.3.3.3 VCP 对垂直耦合板放电数量至少10次,放电位置在VCP垂直中心。耦合板大小为 0.5mX0.5m.与HCP垂直,并保持与EUT 0.1m的距离。 放电施加在耦合板上,EUT的4个面都被测到。
B
C
Test Data only
15kV
None
Table 6.1 ESD Testing Criteria Contact Discharge (R1) Severity Level 1 Dell Requirement Test Data only Level 4kV 6kV 8kV Acceptance Criteria B C None
4.3 ESD limit / ENG0002340
Table 6.1 ESD Testing Criteria Air Discharge (R1)
Severity Level Level Acceptance Criteria
1
2
2kV
4kV
B
B
3
Dell Requirement
8kV
12kV
IEC 61000-4-2 8.3.1和A.5。
8.3.1 EUT放电 对EUT进行的直接或者间接放电应按计划方式。应包括: -- EUT典型的操作状况 -- 是否作为台式设备还是立式设备 -- 施加放电点的位置 -- 对于选择的点,采用直接或者间接的放电方式 -- 电压等级 -- 施加放电点的数量 -- 是否进行安装后的试验 为了制定试验计划,可能需要进行某种调查性试验。 Note 1 参考Annex E评估不确定度 Note 2 由于测试结果的变化,建议Annex F 。
4.3 ESD limit / ENG0002340
说明 R0;R1;R2 LEVEL R2:满足R0和R1要求以及以下要求 --EMC-ESD: Charged Docking, +/-12kV Criteria B ,Agile M6403 --EMC: DELL Spec for EFT and surge per seciton B.2.6 and B.2.7 – R2 column
IEC 61000-4-2 8.3.1和A.5。
8.3.2 EUT直接放电 除非在通用标准,产品标准或产品类标准中有其他规定,ESD只施加在正常 使用时人员可接触到的EUT上的点和面,以下是例外的情况: e ) 由于功能原因对ESD敏感并有静电放电警告标签的连接器或其他解除部分 可接触到的点,如测量,接收或其他通讯功能的射频输入端。 基本原理:许多连接器端子用于处理模拟或数字的高频信息,因而不能使用 充分的过压保护装置。对于模拟信号,可使用带通滤波器解决问题。过 压保护二级管的寄生电容防碍EUT工作频段内的工作。 最终的测试电压不应超过产品说明中规定的限值。 试验应以单次放电的方式进行。在预选点上,至少施加十次单次放电。 注意1:施加在EUT上的放电数量由EUT决定;对于有同步电路的产品可适当 增加放电数量。 连续单次放电之间的时间间隔至少1S,但为了确保系统是否会发生故障,可 能需要较长的时间间隔。 注意2:放电点通过以20次/S或以上放电重复率来进行扫描的方式获得。
4.2 ESD / EN 55024
应通过两种方式进行放电: a ) 对导电表面和接触面的接触放电 应进行200次放电,正负各100次,至少选择4个 点。 台式设备至少一个点对于水平耦合板的中心,也 就是至少50次用于间接放电。其余的点中至少 有50次用于直接放电。所有接触到的点都要被 测到。对不能直接接触到的点,至少进行200 次间接放电(用VCP)。 接触放电使用较低的电压等级。 b ) 对孔和缝,绝缘面进行空气放电
4.3 ESD limit / ENG0002340
Table 6.1 ESD Testing Criteria Air Discharge (R0)
Severity Level Level Acceptance Criteria
1
2kV
4kV
B
B
3
8kV
B
Table 6.1 ESD Testing Criteria Contact Discharge (R0)
IEC 61000-4-2 8.3.1和A.5。
通常,应考虑以下六中情况
例 1 2 3 4 5 6 连接器外壳 金属 金属 金属 绝缘 绝缘 绝缘 涂层材料 无 绝缘 金属 无 绝缘 金属 空气放电 --涂层 --a 涂层 --接触放电 外壳 可接触的外壳 外壳和涂层 ----涂层
注意:若连接器插脚有防静电放电涂层,涂层或设备上采用涂层 的连接器附近应有静电放电警告标签。 a 若产品标准要求对绝缘连接器的各个插脚进行试验,应采用 空气放电。
Copy from Test specification Units Performance Criterion B Remark
EN 55024
4(contact kilovoltage discharge 8(air discharge)
Enclosure port
4.3 ESD limit / ENG0002340
EN 55024- 2010 for ESD讲解
范围
此法规适用于CISPR 22定义的ITE设备。 频率范围0Hz 到400GHz.
3. 定义
3.1 Degradation 由于电磁干扰使得EUT出现不希望的改变
3.2 EUT 受测设备,可以是独立得或者包含若干个单元的系统
3.3 ITE 以下设备: 主要功能用于数据的输入,存储,显示,纠正,传输,处理,交换, 控制;可配置一个或多个终端。 b) 电压不超过600V. 可包括数据处理设备,办公设备,电子商业设备。 a)
4.2 ESD / EN 55024
应通过两种方式进行放电: b ) 对孔和缝,绝缘面进行空气放电 当对EUT的某些部位无法进行接触放电时,应 对设备进行研究并辨别使用者容易接触且 容易出现故障的点,如:按键边缘的缝隙, 或键盘和电话手柄的缝隙.这些部位应按空 气放电方式进行试验.
4.3 ESD limit / EN 55024
4.2 ESD / EN 55024
ESD应对设备在正常使用期间可能被触及到的 点或面施加,包括在用户使用手册中规定 的部位,如:更换色带和更换纸卷时用户 可能触及到的部位。 测试的点由EUT决定,具体参考IEC 61000-4-2 8.3.1和A.5。 当选择测试点的时候,特别注意键盘,刻度 盘,电源开关,鼠标,仪器缝隙,卡的缝 隙,通信口的周边等。
• Refer to ENG0002340 PAGE 7 for detailed photo
ESD Test Process from ENG0002340
7.1 放电点的选择
DELL优先选用dito静电枪。 进行ESD DELL测试首先要满足CISPR 24的要求。 空气放电20次/点;接触放电25次/点。需进行测试的点包括: a) Appendix A要求 b) 每个机箱的金属部分,以及插入机箱的金属模块,执行接触放电 c) 小金属徽记,标签等执行接触放电 d) 用8kV空气放电扫描放电点 执行DELL ESD测试前,先按照CISPR 24要求完成接触4kV和空气8kV的测试。 a) 执行12kV空气放电。执行8kV接触放电。 b) 执行15kV空气放电。 ESD放电以1秒1枪的方式执行。若有错误产生,可放宽到不超过10秒直到系统能够恢复。这 些点包括生物识别纪录(如指纹)和摄像机。 空气放电时,静电枪接触到EUT。 若一测试点执行了一次或者多次后不能持续放电,应标著为PD(Partial discharge). DELL在执 行测试时不使用接地线或接地刷,除非EUT stand alone设备。 如果EUT是不接地设备:为了模拟单次放电,在每次测试前都应把残留的电流清除。按照法 规要求使用470k ohm的放电线。
IEC 61000-4-2 8.3.1和A.5。
8.3.2 EUT直接放电 ESD发生器应保持与实施放电的表面垂直。该举动为了提高结果的重复性。 如果无法保持垂直,应在报告中著名。 发生器的放电回路与EUT至少距离0.2m。当实施放电时,放电回路线缆 不应握在操作者的手上。 接触放电时,发生器的顶端先放电后接触到EUT。 对于表面涂漆的情况,应采用以下的操作程序: 设备制造商未说明涂膜为绝缘层,发生器的电极应穿入漆膜,以便与导 电层接触。如厂商说明漆膜是绝缘层,则应只进行空气放电。这类表面 不应进行接触放电。 空气放电时,ESD发生器快速接近并接触EUT。在每次放电后,发生器从 EUT移开。随后进行再次放电。进行空气放电时,接触放电开关保持 关闭。
Severity Level
1
Level
4kV
Acceptance Criteria
B
4.3 ESD limit / ENG0002340
说明 R0;R1;R2 LEVEL R0:所有DELL产品必须满足的要求。 LEVEL R1:满足R0要求以及以下要求 --EMC-ESD: Direct Pin USB +/-1kV (测试和报 告到+/-2kV ),NIC, Battery port and audio +/2kV ,Agile M6403 --EMC-ESD: Charged Docking, +/-8kV Criteria B ,Agile M6403 --EMC-immunity: system immunity to wireless GSM Criteria ,Agile MC200 --General: supplier comprehensive ongoing regulatory evaluation(SCORE),,Agile ENG0006682