File E88991 Vol. 1 Sec. 23 Page 1 Issued: 2000-08-11 and Report Revised: 2005-07-07 DESCRIPTION
PRODUCT COVERED:
USR, CNR: Component - Magnetic Motor Controllers, Model 812 may be followed by B, may be followed by W, may be followed by E, H or HT, followed by 1A, 1B or 1C; followed by C, S, or V, may be followed by additional letters and/or numbers, may be followed by B or F, may be followed by 3-60 V dc. GENERAL:
The devices are open-type magnetically operated, single-pole,
single-throw or double-throw relays, with normally open and normally closed contacts with single stable, one coil latching.
ELECTRICAL RATINGS:
General Type (812):
15 A, 125 Vac, General Use
10 A, 277 Vac, General Use
5 A, 30 Vdc
TV-5, 120 Vac (N.O. Contacts)
*
File E88991 Vol. 1 Sec. 23 Page 1A Issued: 2000-08-11
and Report Revised: 2006-08-04 High Power Type (812H):
20 A, 125 V ac, Resistive (NO Contacts, UL1950 Applications Only)
20 A, 125 V ac, General Use (NC Contacts, UL1950 Applications Only)
15 A, 125 V ac, General Use
12 A, 277 V ac, General Use, 85,000 cycles (NO Contacts)
12 A, 277 V ac, General Use, 60,000 cycles (NC Contacts)
10 A, 277 V ac, General Use
10 A, 277 V ac, General Use, 100,000 cycles (NO Contacts)
10 A, 277 V ac, General Use, 70,000 cycles (NC Contacts)
7 A, 30 V dc
TV-8, 120 Vac, (NO Contacts)
½ HP, 125 Vac, (NO Contacts)
½ HP, 125 Vac, 15,000 cycles (NC Contacts)
1 HP, 250 Vac, (NO Contacts)
1 HP, 250 Vac, 20,000 cycles (NC Contacts)
812H Ambient: 40ºC maximum @ 20 A maximum (Class A, B or F insulation)
55ºC maximum @ 20 A maximum (Class B or F insulation)
85ºC maximum @ 10 A maximum (Class A, B or F insulation)
85ºC maximum @ 12 A maximum (Class B or F insulation)
85ºC maximum @ 15 A maximum (Class F insulation)
105ºC maximum @ 10 A maximum (Class B or F insulation)
105ºC maximum @ 12 A maximum (Class F insulation) High Power Type (812H) – Additional Ratings:
16 A, 277 V ac, General Use (NO Contacts, UL1950 Applications Only)
10 A, 30 VDC, NO
1/4 HP (5.8 FLA), 125 V ac, 30K cycles, NO
1/4 HP (5.8 FLA), 125 V ac, 15K cycles, NC
1/4 HP (2.4 FLA), 277 V ac, 30K cycles, NO/NC
1/6 hp (4.4 FLA), 125 V ac, 30 k (N.C)
5 FLA, 120 V ac, 100K cycles, NO/NC
1000 VA, 120 V ac, Ballast, NC
16.8 VA, 700 mA, 24 Vac, pilot duty, 100K cycles, NO/NC
C300 pilot duty, NO/NC
File E88991 Vol. 1 Sec. 23 Page 1B Issued: 2000-08-11 and Report Revised: 2005-07-07 ELECTRICAL RATINGS (CONT.):
High Power Type (812E):
20 A, 125 V ac, General Use (UL1950 Applications Only)
15 A, 125 V ac, General Use
12 A, 125 V ac, Resistive 70°C
10 A, 250 V ac, Resistive 85°C (50,000 cycles, No Contacts)
7 A, 250 V ac, Resistive 85°C (50,000 cycles, Nc Contacts)
12 A, 277 V ac, Resistive 85°C
7 A, 30 V dc, Resistive
10 A, 250 V ac, General Use 85°C (100,000 cycles, NO Contacts)
10 A, 125 V ac, General Use 85°C (100,000 cycles, NC Contacts)
NC 5A / NO 7A, 240 V ac, 105°C100K cycles.
NO = Normally Open.
NC = Normally Closed.
1/4 hp, 5.8 FLA, 125 V ac (NO Contacts)
1/4 hp, 2.9 FLA, 250 V ac (NC Contacts)
1/4 hp, 250 V ac 85°C (30,000 cycles, NO Contacts)
1/6 hp, 250 V ac 85°C (30,000 cycles, NC Contacts)
1/8 hp, 3.8 FLA, 125 V ac (NO Contacts)
1/8 hp, 1.9 FLA, 250 V ac (NO Contacts)
1/8 hp, 125 V ac 85°C (30,000 cycles, NO Contacts)
1/10 hp, 125 V ac 85°C (30,000 cycles, NC Contacts)
5.0 FLA, 120 V ac (100,000 cycles)
TV-5 (NO Contacts)
Pilot Duty, 24 V ac, 700 mA, 16.8 VA, 100 kc
C300 Pilot Duty
1000 VA, 120 V ac, AC Electric Discharge Lamp (Ballast), (NC contacts)
812E Ambient: 85ºC maximum @ 12 A maximum
105ºC maximum @ 5 A maximum (Class B or F insulation) *