《旋进漩涡流量计》PPT课件
《旋进漩涡流量计》课件
本PPT课件将介绍《旋进漩涡流量计》的概述、工作原理、结构、测量误差、 应用案例、总结和参考文献。
概述
《旋进漩涡流量计》是一种常用的流量计,主要用于测量流体的体积流量。它采用了旋进漩涡测量原理,具有 精度高、可靠性好等优点。本节将介绍该流量计的基本概念、工作原理以及常见的应用场景。
食品饮料行业
用于测量果汁、牛奶、啤酒等食品饮料的流量。
其他行业
还广泛应用于化工、冶金、环保等行业中的流量 测量。
总结
《旋进漩涡流量计》具有测量精度高、可靠性好等优点,但也存在一些限制。 未来,随着技术的进步,该流量计将继续发展并应用于更多领域。
参考文献
• 文献1 • 文献2 • 文献3
旋进漩涡流量计的结构
仪表主体
含有流量脉冲检测器、信号放大器等电子元件。
信号转换器
用于将传感器脉冲信号转化为标准电将流体压力转化为脉冲信号。
显示器
用于显示流体的体积流量。
工作原理
旋进漩涡流量计通过感知流体中的旋进漩涡现象,计算单位时间内漩涡数量来间接测量流体的体积流量。它基 于流体运动学原理进行测量,能够准确捕捉到流体脉动产生的漩涡信号。
测量误差
1 误差来源
漩涡流量计的测量误差来源包括传感器的灵敏度、信号转换器的精度、环境条件等。
2 误差降低
通过校准、使用高质量的元件以及合理的安装位置等方式可降低误差。
3 评定方法
常用的评定方法有测量误差百分比和重复性误差分析。
应用案例
石化行业
用于测量石油、天然气、液化气等介质的流量。
油脂行业
用于测量食用油、煤油等油脂类介质的流量。
旋进旋涡流量计
旋进旋涡流量计旋进旋涡流量计(Swirl flowmeter)是一种新型的流量计,通过测量流体旋进流动时的涡旋频率来计算流体的流量。
它采用了旋进旋涡效应,使流体在流动过程中形成一个旋转的涡旋,通过测量涡旋的频率和流体的动力学参数,可以准确计算出流体的流量。
旋进旋涡流量计是基于计量主体上流体受到限制而形成的旋涡频率与流体流量之间的关系来进行测量的。
当流体通过流量计时,受到流速平衡约束的流体会在计量主体中形成旋涡,旋涡的频率与流体的流量呈现正相关关系。
通过测量旋涡的频率,再结合一些流体的动力学参数,可以准确计算出流体的流量。
旋进旋涡流量计的优点是可以实现非接触、不易堵塞和可靠性高。
由于其采用的原理比较简单,所以在实际应用中具有一定的优势。
旋进旋涡流量计是一种新颖的流量计,它能够对各种流体进行准确的流量测量。
它具有体积小、重量轻、精度高和使用寿命长等优点。
旋进旋涡流量计主要适用于液体和气体介质的流量测量,可以广泛应用于石油、化工、食品、制药、能源和环保等领域。
旋进旋涡流量计对流体的粘度、密度和温度的变化都有较好的补偿能力,能够在不同工况下实现准确的流量测量。
旋进旋涡流量计的检测原理是基于一些特定的材料,当液体或气体通过流量计时,会在计量主体中形成一个旋涡,而这个旋涡的频率与流体的流量呈线性关系。
通过测量旋涡的频率,就可以计算出流体的流量。
对于液体的流量计,一般采用压力传感器和涡轮传感器来进行测量,而对于气体的流量计,则通常采用压力传感器和温度传感器来进行测量。
旋进旋涡流量计的主要特点是可以实现液体和气体的流量测量,适用于不同的工况和介质,具有较高的测量精度和可靠性。
它具有结构简单、体积小、重量轻、使用寿命长、不易堵塞、可靠性高等优点,在工业领域中有广泛的应用。
旋进旋涡流量计是一种新兴的流量计,随着技术的不断发展,其在流量测量领域的应用前景将会更加广阔。
流量计工作原理ppt课件
涡街流量计
优点 ① 结构简单,无可动部件,长期运行可靠性高; ② 测量精度高; ③ 测量范围宽,量程比可达10:1。 缺点 ① 不适用于低雷诺数测量; ② 安装时上下游需较长直管段。 选用标准 ① 洁净气体、蒸汽和液体的测量; ② 低流速流体及粘度较大的液体不宜采用涡街流量计。
.
电磁流量计
电磁流量计主要由磁路系统、测量导管、外壳、衬里、 电极和转换器等部分组成。
工作原理 基于法拉第电磁感应定律,即当导体在磁场中作
切割磁感线运动时,在导体中会产生电动势,电动势 的大小与导体在磁场中的有效长度和垂直于磁场方向 的运动速度成正比。
同理,导电流体在磁场中作垂直方向流动从而切 割磁感线时,会在管道两边的电极上产生动生电动势。 流体速度越快,产生的电动势就越大。
① 时差法
超声波在流体中顺流、逆流的传播速度不同,导致传播相
同距离时会存在时间差,该时间差与流体的流动速度成正比,
因此测出时间差就可以得出流体的流速。
时差法只能用于高速流动的清洁液体和气体。
② 波束偏移法
流体流动会引起超声波束偏移,流速越大,偏移角越大,
两接收器收到的信号强度差值也越大,因此可以通过测量两接
由于科氏力是惯性力,流体质量越大,产生的科氏力就越大, 丈量管的扭曲角就越大。通过测量扭曲角就可以计算出质量流量。
.
科氏力质量流量计
优点 ①直接测量质量流量, 有很高的测量精确度; ②可测量流体. 范围广泛,
涡街流量计
工作原理 基于卡门涡街原理,在测量管道中设置漩涡发生
热式流量计和旋涡流量计(课件)
• 应力式:
嵌入压电陶瓷片,压力转化成电荷
• 灵敏度高、抗振性差,是当前应用最多的一种检测方式。
• 电容式:
• 差动电容,当前只有德国E+H公司能成功制 造,灵敏度、抗振性均较好。
• 超声式: • 灵敏度、抗振性均较好,仅有日本横河公司
成功制造。
(3)信号处理
• 模拟信号处理:
涡街传感头 电荷放大
• 按检测变量: 温度测量法 以恒定功率提供热量,
测量随着流量而变的温度,又称定功率测量 法。
功率消耗测量法 保持加热元件和被 测流体温度差恒定,控制和测量热源提供功 率,功率消耗随着流量增加而增加,又称恒 温差测量法。
• 按流量传感器结构(有测量管的): 接入管道式 流量传感器必须
在管道待测位置截断后接入。 插入式 插入检测控头到待测
两温度传感器 (热电阻)分别 置于气流中两金 属细管内,一热 电阻测得气流温 度T,另一细管 经功率恒定的电 热加热,其温度 TV高于气流温度, 气体静止时TV最 高,随着质量流 速(ρV)的增 加,气流带走更 多热量,温度下 降,测得温度差。
• 利用热扩散原理制造的流量计有两种 设计方法:一是:基于恒温差原理; 二是基于恒功率原理。基于共同的数 据模型:
管道内。 • 按测量流体:
气体用、液体用
• 过去流程工业用仪表主要是热分布式, 近几年才开发热散(或冷却)效应式。
• 1、热分布式TMF ; • 2、基于金氏定律的浸入型TMF(热扩
散式)。
测量原理
散热原理 :即利用流体流过发热物体 时,发热物体的热量散失多少与流体 的流量成一定的比例关系的原理工作。
• 2 前置直管段
1)热分布式 仪表对上下游配管布置不敏感, 通常认为无上下游直管段长度要求。ISO/DIS 11451认为流量测量不受旋转流和流速场剖面畸 变影响。然而BS 7405却认为;①上下游直管段 长度可小至2D;②在进口端置一金属(或塑料) 网,可有效地改善流速分布畸变,得到分布均匀 的气流;③要防止从小管径突然扩大进入较大口 径仪表,要缓慢过渡。
漩涡旋进流量计
2硬件介绍
起漩器 壳体 流量计积算仪 温度传感器 压力传感器 浓度传感器
流量计算仪
温度传感器
当PT100在0摄氏度的时候他的阻值为100欧姆, PT100在 摄氏度的时候他的阻值为100欧姆, 它的阻值会随着温度上升而成近似匀速的增长。 但他们之间的关系并不是简单的正比的关系,而 更应该趋近于一条抛物线。 铂电阻的阻值随温度 的变化而变化的计算公式: -200<t<0℃ Rt=R0[1+At+Bt+C(t-100)t] 200<t<0℃ Rt=R0[1+At+Bt+C(t(1) 0<t<850℃ Rt=R0(1+At+Bt) 0<t<850℃ Rt=R0(1+At+Bt) (2) Rt为t℃时的电阻值,R0为0℃时的阻值。公 Rt为 时的电阻值,R0为 式中的A,B,系数为实验测定。这里给出标准的 式中的A,B,系数为实验测定。这里给出标准的 系数:A=3.90802*10系数:A=3.90802*10-3℃;B=-5.802*10B=-5.802*107℃; C=-4.27350*10-12℃。 C=-4.27350*10-12℃
旋进旋涡流量计
旋进旋涡流量计内容一、设备概述二、结构及工作原理三、设备使用优缺点四、设备维护重点注意事项五、常见故障及处理措施旋进漩涡流量计(The vortex precession flowmeter )主要用于油田现场天然气的计量。
旋进漩涡流量计可以显示:气体的瞬时流量,累计流量,温度等信息。
一、设备概述场站现场旋进旋涡流量计旋进旋涡流量计结构旋进旋涡气体流量计由传感器、转换器组成。
如图所示,传感器由旋涡发生器(起旋器)、文丘里管、消旋器、旋涡检出元件组成。
起旋器由不锈钢或其他能经受流体冲刷的材料制成,它有特定角度叶片和流线型轴组成,固定安装在收缩段,用于强制流体产生强烈旋涡流。
文丘里管用于旋涡的发展。
消旋器由直叶片组成辐射状流动整流器,安装在扩散段后部。
用于流体的整直,减小对下游设备影响。
旋涡检出元件用热敏元件、应变片、膜片电容等元件检测旋涡振动频率。
工作原理:当沿着轴向的流体进入流量计传感器入口时,在漩涡发生体的作用下,被强制围绕中心线旋转,产生漩涡流,漩涡流在文丘里管中旋进,达到收缩段时突然节流后,使漩涡流加速,当通过扩散段后,因回流作用强迫进行旋进式二次旋转,此时,漩涡流的旋转频率与介质流速成正比,并为线性。
由压电传感器检测到的微弱电荷信号同时经前置放大器放大、滤波、整形后变成两路频率与两速成正比的脉冲信号,积算仪中的处理电路对两路的脉冲信号进行相位比较和判别,剥除干扰信号,而对正常的流量信号进行计数处理。
为了避免下游管件对测量的影响,出口前装有导流叶片,叶片平面与轴线平行,目的是将旋进旋涡梳理成平直流动。
三、设备使用优缺点优点:1.实现了机电一体化, 日常的计量不需要人工值守。
2.体积小、重量轻, 便于离线标定。
3.在工艺安装中, 仪表上、下油直管段较短。
4.流量测量范围较宽, 可在部分小流量区域进行有效工作。
5.流量信号既可就地显示, 也可按需远传。
缺点:1.对噪声或震动等干扰信号较为敏感。
旋进漩涡流量计
旋进漩涡流量计Ⅰ(Ⅱ)旋进漩涡流量计是速度式仪表的一种,当流体沿轴向流入传感器入口时,导流器迫使流体进行旋转运动,产生漩涡流,并在文丘利管中因缩径而加速,到达扩散管后,因回流作用强迫漩涡流产生旋进式二次旋转,其频率与流体流速成正比。
旋进漩涡流量计对流体预先进行导流和加速,其特点是其他流量计无法比拟的,它特别适合于对管道煤气、石油液化汽等流速低、粘度大、密度小的介质的测量。
应用范围:适合于各类流速低、粘度大、密度小的介质的测量,如管道煤气、石油液化汽、天然气、氢气以及各类低流速液体。
适合无市电、经常停电的场合和远程监控系统。
主要特点:具有BTF 系列旋进漩涡传感器的所有特点。
一体化设计,结构紧凑、安装方便。
高度集成,可对被测介质进行定值温压补偿,或实时跟踪的智能补偿。
采用先进的微处理技术,软件功能强大,方便用户操作,并设有密码保护。
采用E2PROM 存储技术,在停电状态下,所有参数和检测数据可永久保存。
双排液晶显示,可同时显示累积流量和瞬时流量。
微功耗双电源设计,内部锂电池供电,寿命可达五年。
配备多种通讯模式供用户选择,可直接实现联网通讯。
精度等级:液体0.5-1.0级 ,气体、1.0-1.5级量程比:15:1温度检测:Pt1000铂电阻,时温分辨率0.01℃压力检测:精度±1.0%供电电源:内供3.6V 锂电池;外供+24V .DCLFXX系列数据输出:工况脉冲信号(三线制)4~20mA标准电流信号(二线制)RS-485通讯接口MEDOM通讯接口防爆等级:dⅡBT2-T4进入流量计的流体通过旋涡发生器产生的旋涡流,旋涡流在文丘利管中旋进,达到收缩段突然节流使旋涡流加速。
在旋涡流发生进动的区域放置压电传感器以检测涡流的进动频率,此频率信号经前置放大器进行放大整形,转换成频率与流量成正比的脉冲信号,最后通过智能流量积算仪中的CPU运算处理,转换为流量的累积值和瞬时值进行显示。
此脉冲信号还可远处给用户计算机等二次仪表进行运算和显示。
CX系列旋进漩涡流量计
CX 系列旋进漩涡流量计1 主要特点⑥内置式压力、温度、流量传感器,安全性能高,结构紧凑,外形美观;⑥采用双传感器、新型信号处理放大器和独特的滤波技术,有效地剔除了压力波动和管道振动所产生的干扰信号,大大提高了流量计的抗干扰能力,使小流量具有出色的稳定性;⑥无机械可动部件,使用维护更方便;⑥对流量计的前后直管段安装要求低(前为≥3DN 、后为≥1DN);⑥一节锂电池可连续使用3年以上,并具有电池欠压两级报警输出功能,更适合与IC卡管理系统的配套使用;⑥流量积算仪可以任意角度定位(转动角为350°),使流量计在各种安装条件下的读数更方便更直接;⑥特有时间显示及实时数据存储之功能,无论什么情况,都能保证内部数据不会丢失;⑥仪表具有RS-485通讯接口功能,并配备功能强大、界面丰富的数据管理软件系统,可打印各种自动生成的图表;⑥仪表具有防爆及防护功能,防爆标志为ExdⅡBT4, ExiaⅡBT4, ExiaⅡCT4防护等级为IP66。
⑥ 多种结构形式1)CX型:智能型,集温度、压力、流量传感器于一体、对温度、压力进行自动补偿。
可直接显示标准状态下(101.325 kPa 20℃)介质的体积总量。
2)CX-B型:普通型,直接显示工况流量和累积量3)CQ-S型:显示标准状态下的流量和累积量,温度、压力为定值设置,特别适用于介质压力,温度相对稳定的场合。
根据用户要求,可提供:•GSM网络功能,实现低成本、远距离无线数据传输;•压力、温度定值设置之功能,特别适用于介质压力,温度相对稳定的场合。
2 技术参数及要求2.1 准确度等级1级±1% 1.5级±1.5%2.2 使用环境环境温度: -30℃~+60℃相对湿度: 5%~95%大气压力: 70kPa~106kPa;流量计不宜用在流量频繁中断和有强烈脉动流(或压力脉动)的场合。
2.3 介质条件⑥ 介质温度: -30℃~+80℃;⑥ 被测流体的流量、压力和温度范围应符合本说明书的规定。
旋进漩涡流量计
旋进漩涡流量计
工作原理
• 当沿着轴向流动的流体进入流量传感器入口时,叶片强迫流体 进行旋转运动,于是在旋涡发生体中心产生旋涡流,旋涡流在 文丘利管中旋进,到达收缩段突然节流使旋涡流加速,当旋涡 流进入扩散段后,因回流的作用强迫进行旋进式二次旋转。此 时旋涡流的旋转频率与介质流速成正比并为线性。压电传感器 检测的微弱电荷信号经前置放大器放大、滤波、整形、比较后 变成频率与流速成正比的脉冲信号,最后送积算仪进行计数处 理。信号采集部分采用两支检测信号为检测点,当漩涡流经两 个压电传感器时,检测到的信号将被送入信号放大部分进行单 独放大。放大后的频率信号再经比较器进行比较,比较器将会 输出与流速成正比的脉冲信号,再送入积算仪进行计数。 • 计算公式 Q=f/K Q:m3/s ;f:Hz ; K:1/m3 Q=3.6×f/K Q:m3/h ;f:Hz ; K:1/L
适用环境
• 主要用于气体的测量,也可用于蒸汽的测量。 • 通常要求压力小于4MPa,温度-40~250摄氏度。 • 气体和蒸汽流速范围1~5m/s。
旋进旋涡流量计特点
• 结构简单而牢固,无可动部件,可靠性高,使用寿命 长; • 测量范围宽,量程比可达1∶10; • 输出信号与流量成线性关系,便于数据处理和上位机 联用; • 在一定雷诺数范围内,输出信号频率不受流体物理参 数(温度、压力、粘度)的影响,仪表系数仅与旋涡 发生体的形状和尺寸有关; • 安装简单,维修方便; • 下限流速较低,适用于天然气等的测量。 • 抗振动干扰能力比涡街强。 • 直管段要求比涡街、孔板小不能正常工作。 • 不适用于液体测量。
CLX系列旋进旋涡智能流量计
23,0,21,2,19,4,17,6,15,8,13,10
目录 一 概述 ·············································································································- 1 二 主要技术参数······························································································- 2 -
旋进旋涡流量计Biblioteka 川立一 概述CLX 系列旋进旋涡智能流量计是集流量、温度、压力检测功能于一体, 并能进行温度、压力自动补偿的新一代流量计,该仪表采用先进的微机技 术与微功耗新技术,功能强,结构紧凑,操作简单,使用方便,是石油、 化工、电力、冶金等行业天然气、一般性气体和饱和蒸汽计量的理想仪表。 该产品的主要特点如下:
2.1 流量范围、基本参数和性能指标 ··························································- 2 2.2 标准状态条件 ··························································································- 2 2.3 使用条件··································································································- 2 2.4 电器性能指标 ·························································································- 3 2.5 防爆等级 ·································································································- 3 三 流量计结构与工作原理 ··············································································- 3 3.1 流量计结构 ·····························································································- 3 3.2 旋进旋涡流量传感器工作原理 ······························································- 4 3.3 流量积算仪工作原理··············································································- 4 四 使用方法······································································································- 7 4.1 流量计选型 ·····························································································- 7 4.2 选型实例 ·································································································- 9 4.3 显示方式 ······························································································· - 10 4.4 流量计参数的设定················································································ - 11 4.5 流量积算仪内部接线方法 ···································································· - 13 4.6 内电源的使用 ······················································································· - 14 4.7 流量计的压力损失················································································ - 14 4.8 流量计外形尺寸及安装········································································ - 14 五 型号与规格································································································- 17 六 旋进旋涡流量变送器 ················································································- 19 6.1 旋进旋涡流量变送器结构 ···································································· - 19 6.2 变送器 B 的工作原理 ··········································································· - 19 6.3 仪表系数 ······························································································· - 19 6.4 调试 ······································································································· - 20 七 使用注意事项····························································································- 21 八 运输、贮存································································································- 21 九 开箱及检查································································································- 22 十 订货须知····································································································- 22 -
正确的使用旋进旋涡流量计
正确的使用旋进旋涡流量计一、旋进漩涡流量计表头显示瞬时流量、压力正常,温度显示与工作现场温度不符1.温度示值为“—75C”或超出“100℃”。
温度传感器损坏。
可更换传感器。
2.温度示值超出或低于现场实际温度,更换传感器后,仍为该现象。
温电路损坏。
可更换温压电路。
二、旋进漩涡流量计表头无显示1.流量计无24V电源或电池供电。
对流量计进行24V供电或更换流量计电池。
2.流量计液晶板损坏。
更换流量计液晶板。
3.流量计主板损坏。
更换流量计主板。
4.电源接线有误或断线。
查找并重新接线。
三、旋进旋涡气体流量计表头温度、瞬时流量有显示,压力与实际工作压力指示不符1.若压力示值为“80”或流量计“压力上限”(上限在流量计选型参考表内可查到)。
一是外接一新压力传感器,看表头是否显示本地大气压,若显示本地大气压,则原传感器损坏。
可更换压力传感器。
二是外接一半新压力传感器,若表头显示仍为“80”,则证明流量计主板坏。
可更换流量计主板。
2.压力示值基本为肯定值(现场工作压力变更较大,流量计表头显示压力无变更或变更较小)。
一是压力传感器取压孔堵塞。
可清理取压孔。
二是压力传感器线性校准曲线变坏。
可更换或重新标定压力传感器。
四、旋进漩涡流量计表头显示温度、压力正常,无瞬时流量显示1.流量计选型过大,选型过大会造成流量计无流量显示。
一是调低流量计下限截止频率(这样流量计可以使用,但会造成流量计精度降低)。
二是更换小规格流量计。
2.前置放大器无电流输入。
流量计无电源供电,进行流量计24V外部电源或电池供电。
3.前置放大器无频率输出。
可更换前置放大器。
4.主旋进漩涡流量计板损坏。
可更换流量计主板。
渭南和顺达流量计厂家生产的旋进旋涡流量计现在被广泛应用于石油、化工、电力、冶金、城市供气等职业各种气体流量丈量的流量计,运用旋进旋涡流量计要遵奉并服从以下五点要求,这么才略确保丈量的性。
下面和顺达技术我介绍如何正确的使用旋进旋涡流量计。
1、选型旋进旋涡流量计广泛应用于天然气、煤气等职业,功用平稳,计量,装置便利,在现已确定要选用旋进漩涡流量计的情况下,紧接着即是对流量传感器标准及其配套元件的选择至关紧要。
各种流量计的基本原理培训ppt课件
采气时:0-25000m3h对应靶式输出124mA
2、注采气之后:看流量计的零点是否正确,则需要对进行调整。
3、双向流靶式流量计在测量气体时的温度-压力补偿方式
靶式流量计在出厂时是按设计院提供的操作压力、温度、管径、量程范围等参数进行标定 出厂的。但是,在实际工艺操作过程中,压力和温度随时随刻都在变化(实时值),这样就 造成靶式流量计输出产生偏差,为了消除由于操作压力和操作温度偏离标定值带来的误差, 因此,必须对测量气体的靶式流量计进行温度-压力补偿,使输出能反映流量的真实值。一 般在DCS系统上即可完成温-压补偿,如下式:
计量专业
1
储气库现有流量计种类: 1、电磁流量计 2、旋涡旋进流量计 3、靶式流量计 4、超声流量计
2
流量计的基本原理
3
一、电磁流量计 原理
电磁流量计是根据导电流体通过外加磁场时感生 的电动势来测量导电流体流量的一种仪器(法拉 第电磁感应定律)。就是当导体在磁场中作切割 磁力线运动时,在导体中会产生感应电势。
4、4.1.注气过程:
第一步:在注气之前,必须将靶式流量计前端1#球阀处于完全关闭状态,避免瞬间高压直 接冲击靶板造成流量计靶杆被打弯或传感器损坏。
第二步:通入气体后,应缓慢开启流量计前端控制阀门,将控制阀的开度控制在10~15%之 间。然后缓慢开启手动1#球阀,最好把开度控制在60%处。
第三步:这时再用流量计前端的控制阀来控制注气流量值的大小。
6
二、旋涡旋进流量计
组成
1.旋涡发生体:用铝合金制成,具有一定角度的螺旋叶片,它固定在壳体 收缩段前部,强迫流体产生强烈的漩涡流。 ⒉ 壳体: ⒊ 智能流量计积算仪 4. 温度传感器:以Pt1000 铂电阻 为温度敏感元件。 5. 压力传感器:以压阻式扩散硅桥路 为敏感元件。 6. 压电晶体传感器:检测出漩涡进动 的频率信号。 ⒎ 消旋器:作用是消除旋涡流, 以减小对下游仪表性能的影响。
旋进流量计初级培训精讲
个值,或者在0与某个值之间波动,这个瞬时值有可能很大,大到超满量程。
具体的解决方法请看干扰消除步骤。 7. 实际管道有流量,但是瞬时量显示为零,解决方法是将Qmin值设置变小。
© ABB Group October 5, 2018 | Slide 21
交流时间
© ABB Group October 5, 2018 | Slide 22
© ABB Group October 5, 2018 | Slide 17
案例共享:
5)处理方法: a. 给用户解释清楚菜单: Compressibility的意义,让用户根据不同的压力值 和温度值,重新计算温压补正系数,才能做到准确测量。 b.如果压力,温度值变化频繁,频繁的去修改此数值,工作量大,似乎也不 现实。最好能在此工艺点附近采集压力值,温度值,让旋进输出工况值,在 DCS上根据这3个值做温压补正,才能得到正确的测量值。
© ABB Group October 5, 2018 | Slide 8
转换器(表头)的方向:
当传感器在管道上固定好后,可以将表头调节到合适的方向,便于操作和观 察和消除表头进水的隐患。
© ABB Group October 5, 2018 | Slide 9
接线:
© ABB Group October 5, 2018 | Slide 10
© ABB Group October 5, 2018 | Slide 16
案例共享:
2. 介质为氧气时,用户需要测量标况流量(Qn), Flow mode: Qn
Compressibility: 23.72
1)当需要测量标况流量时,仪表需要输入温压补正系数,由直接测量的体 积流量和输入的补正系数,来计算出用户需要的标况流量。 2)一般情况下,用户在我方仪表测点的同一管线上还有一套流量仪表,由 节流元件(孔板,V锥,威力巴等),差压变送器,压力变送器,热电阻四 台仪表组成,将采得的这3组值,在DCS上做动态的温压补正,这个值肯定 是准确的。 3)但是我方仪表上的补正系数是根据固定的压力和温度值计算得出,原因 同蒸汽仪表一样,这个系数是根据当初的规格书上算出,但实际安装到现场, 在压力温度不停的变化时,这个系数根本就不可取。 4)当压力,温度频繁变化时,仪表的输出值肯定跟实际的瞬时值有很大的 差距。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
精选ppt
10
流量计的结构图
精选ppt
11
基本部件示意图(一)
精选ppt
12
基本部件示意图(二)
精选ppt
13
流量计的显示屏显示内容
精选ppt
14
工况与标况的换算关系
精选ppt
15
流量计故障分析
精选ppt
16
故障判断步骤
精选ppt
17
影响旋进漩涡流量计正常工作的因素
1.工况因素 :没有气量、气量小、工作 压力、温度过高或过低。 2.设备自身因素 :电池没电、保险烧、 电缆老化、接头脱、模块坏等原因造成 流量计不能正常工作。 3.外界、人为等因素:接线错误、系数没 有更改。
23、绝对压力、表压、大气压
P表压 = P绝对压力 - P大气压
24、 上、下限绝对压力
以压阻式扩散硅桥路为敏感元件,其桥臂电阻在外界压力
作用下会发生预期变化,因此在一定激励电流作用下,其两输
出端的电位差与外压力成正比。
14、流量传感器(探头)
将流体介质的流速变化转换为相应电信号的器件。
15、 放大器(简称前置)
将流量传感器输出的微弱信号进行放大处理,变成能被二
次仪表或装置接收的电信号的装置。
在工况条件下,单位时间内流过管道横截面的流体体积量
精选ppt
22
6、标准体积流量
单位时间内流过的工况体积量折算至标准状态下(温度为
293.15K,压力为101.325kPa)的体积量。
7、标准体积总量
在一段时间内流过的标准体积流量之和。
8、最小流量Qmin
流量计在工况使用条件下,测量误差不超过基本误差限的下限
精选ppt
21
流量计基本术语
1、流量补偿仪 将温度、压力及流量传感器输入的信号经相关处理,由微处
理器(MCU)运算及处理后分别得到流体的温度、 压力和标准体积流量、总量等数据,并对相关数据进行记 录处理形成可供查询的历史数据记录。 2、流量 单位时间内流过管道横截面的流体量,也称瞬时流量,单位:
m3/h;l/min。 3、工作状态(简称工况) 在流体实际所处的温度和压力下的状态称为工作状态。 4、标准状态(简称标态) 流体处于温度20℃,压力为101.325Kpa下的状态称为 标准状态。 5、工况体积流量
精选ppt
18
故障现象及分析
精选ppt
19
精选ppt
20
监控岗监测气量故障可能出现的情况
故障一:监测气量值为零
1、没有气或气量小;
2、仪表故障;
3、电池无电;
4、保险烧;
5、接地不好
故障二:监测气量值偏小
1、井本身气量减小;
2、仪表故障;
3、接地不好
故障三:监测气量值偏大
1、井本身气量增大;
2、仪表故障;
16、 RS485数据通信
采用IEEE-RS485标准在功能部件之间按某种协议传送数
据。
17、 通信协议
一套语义和语法的规则,它用于规定功能部件或接口在
通信过程中的行为。
18、 数据采集器 指采用特定的软件、硬件组成,可与流量补偿仪及电话网络连
接的设备。
19、 脉冲频率
单位时间(1s)内的脉冲个数
精选ppt
旋进漩涡流量计
精选ppt
1
内容
概述 旋进漩涡流量计工作原理 旋进漩涡流量计技术参数 旋进漩涡流量计结构和组成 旋进漩涡流量计故障检查和处理方法
精选ppt
2
概述
旋进漩涡流量计是一种速度式流量 计,是集流量、温度、压力检测功能 于一体的新一代流量计,可对被测气 体的温度、压力和压缩因子自动跟踪 修正,直接检测气体的标准体积流量 和总量。
产生漩涡流,漩涡流在文丘利管中旋进,到达
收缩段突然节流后,使漩涡流加速,当通过扩
散段时,漩涡中心沿一锥形螺旋线进动。此时,
由压电传感器检测到的漩涡两路与流
速成正比的脉冲信号,经积算仪中处理电路进
行相位的比较和判断,并剔除外来干扰信号后
与温度、压力传感器检测到的信号一起送入智
精选ppt
5
流体振动流量计有三类: 涡街流量计、旋进(旋涡进动) 流量计和射流流量计。
流体在流动中常常产生漩 涡。流体因回旋而产生的漩涡 是一种强制振荡旋转型漩涡, 用这种原理制成的流量计叫旋 进式漩涡流量计。
精选ppt
6
工作原理
当沿着轴向的流体进入流量传感器入口时,
在起漩器的作用下,被强制围绕中心线旋转,
精选ppt
3
精选ppt
4
测量原理
在流动的流体中放置一个柱形钝 体,就会在柱体下游两侧产生两列有 规律的旋涡,伴随旋涡的产生,在柱 体周围和下游的流体将产生有规律的 振动,其振动频率与流量存在对应关 系.约束的旋流在通过扩大管时,会 产生涡流进动现象,流体发生振动, 其振动频率与流速成正比关系.利用 流体振动频率来测量流量的仪表,就 称为流体振动式流量计。
24
20、 4mA-20mA电流输出
将要传输的数据按零流量(0m3/h)对应4mA输出,最大流量对
应20mA输出的工业标准接口。
21、仪表系数
单位工况体积的流体流经流量传感器时所输出的脉冲数,以
(1/m3)为单位。
22、平均仪表系数
在规定的流量范围内,各流量点的仪表系数中,最大值与最小
值的算术平均值,以K0表示(也称仪表系数)。
流量。
9、最大流量Qmax
流量计在工况使用条件下,测量误差不超过基本误差限的上限
流量。
10、测量范围
由最小流量和最大流量所确定的范围。
11、范围度
流量计的最大流量与最小流量的比值。
12、温度传感器
以Pt100铂电阻为温度检测元件,在一定温度范围内,其电
阻值与温度成正比关系。
精选ppt
23
13、压力传感器
能流量积算仪进行运算处理,并把流体的体积
流量和总量直接显示于LCD屏上。
精选ppt
7
工作原理示意图
精选ppt
8
技术参数
公称通径 型号规格 (mm)
流量范围 (m3/h)
压力等级 (MPa)
精度
Qmax时 压力损 失(kPa
)
壳体材料
TDS-25B
25
2.5~30
3.30
TDS-32B
32
4.5~60
1.6;
2.10
2.5;
1.0
≤2.5MPa,
TDS-80D
80
18~200
4.0;
2.90 铝合金;
TDS-80B
80
28~400
6.3;
4.20 ≥4.0MPa
10;
1.5
,不锈钢
16
3.90
5.40
精选ppt
9
流量计的结构
流量计由以下七个基本部件组成: ⒈ 旋涡发生器(起漩器) ⒉ 壳体 ⒊ 智能流量积算仪 ⒋ 信号检测仪(压电晶体传感器) ⒌ 温度传感器 ⒍ 压力传感器 ⒎ 整流器(消漩器)