H3C S5560-30C-PWR-EI 风扇告警处理过程

一、故障现象

1、现场交换机告警信息

1.1、交换机前面板指示灯状态

1.2、交换机后面板指示灯状态

1.3、交换机后面板指示灯状态(视频)

故障时交换机后面

板.mp4故障时交换机后面板风扇.mp4

2、交换机告警信息

%Mar 11 22:13:53:241 2013 S5560#1 SHELL/5/SHELL_LOGIN: TTY

logged in from aux0.

%Mar 11 22:13:59:481 2013 S5560#1 DEV/1/FAN_DIRECTION_NOT_P

REFERRED: Fan 1 airflow direction is not preferred on slot 1, please check it.

%Mar 11 22:13:59:482 2013 S5560#1 DEV/1/FAN_DIRECTION_NOT_PREFERRED: Fan 2 airflow direction is not preferred on slot 1, please check it.

display device manuinfo

Slot 1 CPU 0:

DEVICE_NAME : S5560-30C-PWR-EI

DEVICE_SERIAL_NUMBER : 210235A1FYC162000023

MAC_ADDRESS : 50DA-00E3-EE00

MANUFACTURING_DATE : 2017-04-07

VENDOR_NAME : H3C

Fan 1:

The operation is not supported on the specified fan.

Fan 2:

The operation is not supported on the specified fan.

Power 1:

DEVICE_NAME : LSPM1AC360

DEVICE_SERIAL_NUMBER : 210231A2PHH172000103

MANUFACTURING_DATE : 2017-02-10

VENDOR_NAME : H3C

Power 2:

DEVICE_NAME : LSPM1AC360

DEVICE_SERIAL_NUMBER : 210231A2PHH172000157

MANUFACTURING_DATE : 2017-02-10

VENDOR_NAME : H3C

display fan

Slot 1:

Fan 1:

State : FanDirectionFault

Airflow Direction: Port-to-power

Prefer Airflow Direction: Power-to-port

Fan 2:

State : FanDirectionFault

Airflow Direction: Port-to-power

Prefer Airflow Direction: Power-to-port

二、故障分析

设备支持两种型号的风扇模块,分别对应两种风道方向:端口侧进风、电源侧出风;电源侧进风、端口侧出风。用户应根据机房通风散热系统的方向来选择风扇模块的型号和配置设备的期望风道方向,并确保这三个方向一致。

H3C LSPM1FANSA

%26 LSPM1FANSB 风扇

当风扇模块的风道方向与设备当前期望的风道方向不符时,设备会发出较大的噪声,系统指示灯为红色告警,同时控制台会打印Log信息提醒用户。

三、故障处理

此时,登录设备,配置期望风道方向跟风扇模块一致,问题消失。

system-view

System View: return to User View with Ctrl+Z.

[S5560#1]

[S5560#1]fan ?

prefer-direction Set the preferred fan direction

[S5560#1]fan prefer-direction ?

slot Specify the slot number

[S5560#1]fan prefer-direction slot ?

<1> Slot number

[S5560#1]fan prefer-direction slot 1 ?

port-to-power From port to power

power-to-port From power to port

[S5560#1]fan prefer-direction slot 1 port-to-power

[S5560#1]%Mar 11 22:47:45:082 2013 S5560#1 DEV/5/FAN_RECOVERED: Fan

1 recovered.

%Mar 11 22:47:45:083 2013 S5560#1 DEV/5/FAN_RECOVERED: Fan 2 recovered.

[S5560#1]

[S5560#1]display fan

Slot 1:

Fan 1:

State : Normal

Airflow Direction: Port-to-power

Prefer Airflow Direction: Port-to-power

Fan 2:

State : Normal

Airflow Direction: Port-to-power

Prefer Airflow Direction: Port-to-power

[S5560#1]