Absolute Maximum Ratings

Symbol Conditions 1)

Values Units V CES V GES I C I CM T j T stg V isol

T heatsink = 25 / 80 °C

t p < 1 ms; T heatsink = 25 / 80 °C AC, 1 min.

1200± 20125 / 85250 / 170– 40 . . . + 150– 40 . . . + 125

2500V V A A °C °C V Inverse Diode I F = –I C I FM = –I CM I FSM

I 2

t

T heatsink = 25 / 80 °C

t p < 1 ms; T heatsink = 25 / 80 °C

t p = 10 ms; sin., T j = 25 °C t p = 10 ms; sin., T j = 25 °C 80 / 53160 / 1067202600

A A A A 2s

Characteristics

Symbol Conditions 1)

min.typ.

max.

Units

IGBT - Inverter

V CEsat

t d(on)

t r

t d(off)

t f

E on + E off C ies R thjh

I C = 100 A T j = 25 (125) °C V CC = 600 V; V GE = ± 15 V I C = 100 A; T j = 125 °C R gon = R goff = 11 Ωinductive load V CE = 25 V; V GE = 0 V, 1 MHz

per IGBT –

–––––––2,5(3,1)50

55

400

70

27

6,6

–3,0(3,7)

100110600100––0,25V ns ns ns ns mJ nF K/W Diode 2) - Inverter

V F = V EC V TO

r T

I RRM

Q rr

E off

R thjh

I F = 75 A T j = 25 (125) °C

T j = 125 °C T j = 125 °C I F = 75 A, V R = – 600 V di F /dt = – 800 A/µs V GE = 0 V, T j = 125 °C per diode –––––––

2,0(1,8)1,0

11

45

11

3,0

2,5(2.3)

1,215–––0,8V V m ΩA µC mJ K/W Current sensor for three phase output ac current (SKiiP 83 AC 12 I)I p RMS I pmax RMS

I p peak

R out

I s RMS

I p : I s Offset error Linearity

delay time Bandwidth

Continuous current,

T = 100 °C, V suppl = ± 15 V

t ≤ 2 s t ≤ 10 µs terminating resistance rated sensor current at I p = 50 A RMS

transfer ratio

I P = 0 A, T = – 40 ... 100 °C

I P =10 % – 80 %

90 % – 20 %

––––––––50–100050251 : 2000± 0,20,1< 1< 10 – 100–80––––––(– 3dB)A A A ΩmA mA %µs µs kHz Temperature Sensor

R TS T = 25 / 100 °C

1000 / 1670

ΩMechanical Data

M 1

Case case to heatsink, SI Units mechanical outline see pages

B 16 – 11 and B 16 – 12

2,5

–M8

3,5

Nm

SKiiP 83 AC 12 - SKiiP 83 AC 12 I MiniSKiiP 8

SEMIKRON integrated intelligent Power SKiiP 83 AC 12SKiiP 83 AC 12 I 3)SKiiP 83 AC 12 IS 4)IGBT

3-phase bridge inverter

Case M8

UL recognized file no. E63532

•more detailed characteristics of

current sensors and temperature sensor please refer to part A •

common characteristics see page B 16 – 4

Options

•also available with powerful free-wheeling diodes. Data sheet on request

1)T heatsink = 25 °C, unless otherwise specified

2)

CAL = Controlled Axial Lifetime Technology (soft and fast recovery)

3)With integrated closed loop current sensors

4)

Extended current range, data sheet on request

~~~